Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹36.6 LAccepted-AOC WARD NO 9 HOUSE NO 41 ARYA SAMAJ GALI UDHAMPUR 182 101 J K | UDHAMPUR | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L-1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L-2₹39.9 L+₹3.3 L (9.08%)Rejected-Finance 1 181 KAMATCHI AMMAN KOVIL STREET KANNAN COLONY CHINTHAMANI MADURAI 625009 | MADURAI | MADURAI | TAMIL NADU | 625009 | L-2 | Rejected-Finance other than L-1 | |
| 3 | L-3₹49.6 L+₹13.0 L (35.4%)Rejected-Finance 94 PHASE II HOUSEING COLONY UDHAMPUR J K | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L-3 | Rejected-Finance other than L-1 |
Tender Value
₹34.1 L
EMD Value
₹68,300
Closing Date
30 Jun 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Sh A K Dubey IDSE SE CWE
Military Engineer Services, Commander Works Engineer, Udhampur, PO - Garhi, Udhampur-182121
PROVN OF 03 X STORE ROOM (SIZE 13.00 X 4.50 MTR) FOR ASC BN UNDER GE (NORTH) UDHAMPUR
2022_MES_505609_1
CA NO CWE/U(N)-97/2021-22
Open Tender
Civil Works
Lump-sum
180 days
UDHAMPUR
As per tender documents
7 documents required · 7 mandatory
₹500
GE (NORTH) UDHAMPUR
₹68,300
Yes
14 Jul 2022
3 Feb 2022
2 Jul 2022
3 Feb 2022
30 Jun 2022
18 Jun 2022
60 days
Amount
BUILDING WORK (SCHEDULE 'A' PART-I) Lump sum price worked out by the Contractor for “Building Work” as listed in Schedule ‘A’ Part- I.
INTERNAL ELECTRIFICATION (SCHEDULE 'A' PART-II) (SEC-I) Lump sum price worked out by the Contractor for “Internal Electrification” as listed in Schedule ‘A’ Part- II (Sec-I)
INTERNAL ELECTRIFICATION (SCHEDULE 'A' PART-II) (SEC-II) SCHEDULE `A' PART-II, Sec-II is not prepriced by MES and prepriced rates indicates 0.0 under column 5 signified this fact only. Bidder shall insert their rates in Green filed under Col-6.
Decorative ultra slim linear surface mounted LED lighting fixture (4 feet length), 20Watt LED with integral electronic driver complete making connection and testing after fixing all as specified and directed by Engr-in-charge.The specification of light fitting should meet the following : - (a) Housing of Light fitting : Aluminium Extruded (b) Operating Voltage : Between 150 V- 270V (c) Operating Temperature : -10 to +45 Degree Centigrade (d) Lumen efficacy : Not less than 110 lm/W (e) System Lumens : Not less than 2000 lm (f) Colour Temperature : Not less than 5700K (g) Surge Voltage Protection : Up to 2KV (h) Ingress protection : IP 20 (j) Total Harmonic Distortion (THD) : Not less than 20% (k) Power factor : Not less than : 0.90 (l) Line protection : Under/Over voltage Protection (m) Input Frequancy : 50 Hz
Exhaust fan AC single phase 230/240 V of size 300mm sweep with louver speed 900-950 RPM power input 50-55 W, Heavy duty, complete all as specified and as directed by Engr-in-Charge.
Ceiling fan AC single phase 230/240 volts of size 1200 mm sweep , five star rating complete all as specified and as directed by Engineer-in-Charge.
Note for Srl item Nos 3.01: (i) A certificate from the manufactures for warranty minimum upto 2 years shall be obtained and submitted to the AGE/GE (ii) Any touch up of the wall surface due to changing of fittings shall be done by contractor with similar surface finish without extra cost to the department.
MCB SP, 6 to 32 Amps, 'B' series 10 KA 240 Volts including providing aluminuium thimbles for outgoing cable, complete all as specified and as directed by Engr-in-Charge. Note : The exact capacity of MCB shall be as directed by Engr-in-Charge.
MCB SPN, 40 to 63 Amps, 'B' series 10 KA , 240 Volts including providing aluminuium thimbles for outgoing cable, complete all as specified and as directed by Engr-in-Charge. Note : The exact capacity of MCB shall be as directed by Engr-in-Charge.
Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6mm thick buried directly in ground, (Earth pit not less than 2.25 mtr deep below ground level) with top edge of plate not less than 1.5 mtr below normal ground level, connected to and including 4mm dia galvanized iron wire lead by means of bolts, nuts, check nuts and washers of galvanized standard iron or steel all as specified or indicated in electrical plate No 3 of MES Part-I, including testing on completion including the material and labour and taking out old unserviceable earthing of the following :- (a) Excavation and earth work for drilling hole for electrode in any type of soil. (b) PCC pit in cement concrete 1:2:4 type B-1. (c) Precast RCC cover with suitable handle 40 mm thick in PCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than 1.87 Kg/Sqm. (d) Funnel with watering pipe of GI 20 mm nominal bore medium grade and copper lugs etc all as specified.
Srl item No 3.07 Contd … (e) 15 mm nominal bore light grade GI protection pipe 7.5 mtr long for protection of earthing lead from mechanical injury or tempering. (f) Requisite quantity of common salt and charcoal. (g) Testing of earthing. Note : On testing after completion of earthing, if the desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk and cost to the entire satisfaction of the Engineer-in-Charge.
New generation energy saving and environmental friendly long life LED street light of 35 watt with high power LED as lighting source and lens embedded PC cover having TOP OPENING seperate driver compartment and impact resistance of IK07 with High efficiency long life LED with SMD LED on MCPCB Powered by Built-in, isolated electronic LED driver (SMPS based constant current supply) complete making connection and testing after fixing, complete all as specified and directed by Engr-in-charge. The specification of light fitting should meet the following : - (a) Housing of Light fitting : Aluminium Die Cast (b) Diffuser : High efficient LENS Optics (c) Operating Voltage : Between 150 V- 270V (d) Operating Temperature : -10 to +45 Degree Centigrade (e) Lumen efficacy : Not less than 100 lm/W (f) System Lumens : Not less than 2500 lm (g) Colour Temperature : Not less than 5700K (h) Surge Voltage Protection : Up to 4KV (j) Ingress protection : IP 65 (k) Total Harmonic Distortion (THD) : Not less than 20% (l) Power factor : Not less than : 0.9 (m) Line protection : Under/Over voltage Protection (n) Input Frequancy : 50 Hz
Note for Srl item No 3.09 (i) A certificate from the manufactures for warranty minimum upto 2 years shall be obtained and submitted to the AGE/GE (ii) Any touch up of the wall surface due to changing of fittings shall be done by contractor with similar surface finish without extra cost to the department.
Sub Total
PATH (SCHEDULE 'A' PART-III) Lump sum price worked out by the Contractor for “PATH” as listed in Schedule ‘A’ Part- III .
EXTERNAL ELECTRIFICATION (SCHEDULE 'A' PART-IV) Lump sum price worked out by the Contractor for “External electrification” as listed in Schedule ‘A’ Part- IV .
AREA DRAINAGE (SCHEDULE 'A' PART-V) Lump sum price worked out by the Contractor for “Area Drainage” as listed in Schedule ‘A’ Part- V
EARTH WORK AND SITE CLEARANCE (SCHEDULE 'A' PART-VI) Lump sum price worked out by the Contractor for “Earth work and site clearance” as listed in Schedule ‘A’ Part- VI .
R K BUILDERS
SHIVAE CONSTRUCTION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .