| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹40.7 LAccepted-AOC | 1 | Accepted-AOC L1 | |
| 2 | 2₹1.2 Cr+₹69.2 L (139.7%)Rejected-Finance | 2 | Rejected-Finance Other than L1 | |
| 3 | Rejected-Technical BASUDEVPUR KHANJANCHAK HALDIA EAST MEDINIPUR EAST MEDINIPUR WEST BENGAL 721602 UDYAM WB 12 0002620 | MEDINIPUR EAST | WEST BENGAL | 721602 | - | Rejected-Technical Technically rejected. |
Tender Value
Refer Docs
EMD Value
₹38,400
Closing Date
1 Jul 2020, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
DGM(T)
Haldia-Mourigram-Rajbandh-Barauni Pipelines, P.O. Duilya, Andul-Mouri, Mourigram Distt. Howrah 711 302.
Combined station works (CSW) for Replacement of Booster pumping units (BP-1 and BP-2) at HMRBPL Haldia, in West Bengal
2020_HMRBM_118976_1
HMRBTS2013
Open Tender
Mechanical Works
Works
180 days
HMRBPL, Haldia
Please refer to Tender.
6 documents required · 6 mandatory
₹38,400
Yes
14 Jul 2021
17 Jun 2020
2 Jul 2020
17 Jun 2020
1 Jul 2020
17 Jun 2020
120 days
Amount
Contractor Supply Items-Mechanical (Rates inclusive of P&F charges, freight, Inspection & insurance without GST)
10.75 "OD X 0.365" WT, API 5L Gr. B Pipe
8.625" ODX0.322" WT ASTM A106 GR. B STEEL PIPES
RED,CONC,BW,CS,A234,WPB,12X10IN,150
TEE EQUAL 10IN 150
ELBO,90,LR,BW,CS,A234,WPB, 8IN, 150
10", WNRF FLANGE, ANSI - 150# (B 16.5)
8", WNRF FLANGE, ANSI - 150# (B 16.5)
10", BLRF FLANGE, ANSI - 150# (B 16.5)
12", WNRF FLANGE, ANSI - 150# (B 16.5)
12" SWMG ANSI 150#
10" SWMG ANSI 150#
8" SWMG ANSI 150#
Fasteners for Flanges 10" x 150# (0.875" Dia. X 5.25" Length)
Fasteners for Flanges 8" x 150# (00.750" Dia. X 4.75" Length)
Fasteners for Flanges 12" x 150# (0.875" Dia. X 5.50" Length
Half Coupling 1" 3000#
Nipple Straight 1" 3000#
Nipple reduced 1" x 3/4" 3000#
1"x ANSI 800# HOV W/W API 602 Gate Valve
1.315" OD x 0.179"WT ASTM A 106 Gr B Bare pipe
1" ANSI 150# 90 deg LR Bends
Contractor Supply Items-T & I (Rates inclusive of P&F charges, freight, Inspection & insurance without GST)
CABLE GLAND 1" NPT FLP/WP
CABLE GLAND 1¼IN NPT FLP/WP
CABLE GLAND - 3/4IN NPT FLP/WP
CABLE GLAND - 1/2IN NPT FLP/WP
Plugs F/Junction Box, 1 IN NPT(M), explosion proof
Plugs F/Junction Box, 3/4 IN NPT(M), explosion proof
Plugs F/Junction Box, 1/2 IN NPT(M), explosion proof
Reducer Brass Nickle 3/4 IN NPT x 1/2 IN NPT, explosion proof
Reducer Brass Nickle 1 IN NPT x 1/2 IN NPT explosion proof
Supply of Pressure Indicators (PI) of the range 0 to 20 Kg/cm2 as per the technical specifications attached in the Tender
Supply of Pressure Indicators (PI) of the range 0 to 40 Kg/cm2 as per the technical specifications attached in the Tender
FLP/WP Junction Box-Type C (Bottom entry suitable for 1 no. 40Cx1.5 sqmm, Left side entry suitable for 1 no. 12Cx1.5 sqmm & 2 nos. 4Cx1.5 sqmm, Right side entry suitable for 2 nos. 12Cx1.5 sqmm & 1 No. 4Cx1.5 sqmm control cable)
Fitting, Bushing, 25.4 mmx12.7 mm NPT (F), Material: Carbon Steel, Manufacturing process: Forged, Material Specification, A105, End Finish: Threaded, conform to ANSI 16.11
Male Connector, 12.7 mm MNPTx12.7 MM OD Tube, Material: SS316, 211 kg/sqcm (3000 psi) complete with ferrules & nuts as per ANSI B.2.1
Female Connector, 12.7 MM FNPTx12.7 MM OD Tube, 211 kg/sqcm (3000 lbs) complete with ferrules and nut as per ANSI B.2.1, Material: SS316
Union Tee, 3x12.7 MM OD Tube, 211 kg/sqcm (3000 lbs) as per ANSI 16.11, Material: SS316
Tube End Cap (Sq Head), 12.7 MM OD Tube, 211 kg/sqcm (3000 lbs) as per ANSI B 16.11, Material: SS316
Plug (Sq. Head) 12.7 MM (1/2") NPTM, 211 Kg/CM2, (3000 psi) as per ANSI B 16.11, material SS316
90 Deg ELBOW 12.7 MM (1/2") FNPT x 12.7 MM (1/2") FNPT, 211 KG/CM2 (3000 psi) as per ANSI B 16.11, Material SS 316
HEX Nipple, 12.7 MM MNPTx12.7 MM MNPTx80 MM Long, material SS316
Process Tube, Material: Stainless Steel, Manufacturing process: Seamless, Mat Specification: ASTM A269, grade: IP316, end Finish: Plain End, 1/2 IN OD, 0.065 IN Thick ness, 3000 MM Length
2 Way Valve manifold 2 x12.7 MM FNPT, Material: SS316 with blanking plug for each port
Multiport Valve 12.7 MM (1/2" MNPT) + 3 x 12.7 MM (1/2" FNPT), Material SS316
Needle Valve 12.7 MM (1/2" FNPT) x 12.7 MM (1/2" FNPT), MATERIAL SS316
CONTROL CABLE, Conductor material: Copper, Insulation material: PVC, Core: Multicore, Voltage: 660/ 1100V, Standard designation: IS 1554.
SIZE: 4C X1.5 SQMM
SIZE: 12C X1.5 SQMM
SIZE: 40C X 1.5 SQMM
Contractor Supply Items-Pressure Switch (Rates inclusive of P&F charges, freight, Inspection & insurance without GST)
Pressure Switch with junction box and cable glands suitable for low pressure side, set point (-) 1 to 10 Kg/cm2. Proof Pressure 200 Kg/cm2, Make ITT or CCS
Pressure Switch with junction box and cable glands suitable for high pressure side, set point 3 to 25 Kg/cm2. Proof Pressure 200 Kg/cm2, Make ITT or CCS
Composite Items-Civil works (Rates inclusive of all without GST)
Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead.
Demolishing plastered/unplastered brick work in cement mortar at all heights and depths including following all safety requirements, ensuring adequate precaution to the neighbourhood structures & equipment, putting necessary cover , stacking of unerviceable materials and disposal of unserviceable material within station area limit all completed as directed by Site Engineer.
Demolishing R.C.C. work in existing building structures at all heights and depths using pnuematic tools or chemicals or core cutter as approved by Engineer-in- charge including following all safety requirements, ensuring adequate precaution to the neighbourhood structures & equipment, putting necessary cover , stacking of reinforcement bars and disposal of unserviceable material within station area limit all complete as directed by Site Engineer. Note: 1. Dismantling shall be allowed during day shift only & prior permission for the same shall be obtained. 2. Providing of necessary covers/barricades around the work area is to be done prior to dismantling operations.
PCC dismantling: Demolishing P.C.C. work in existing building structures at all heights and depths using pnuematic tools or as approved by Engineer-in- charge including following all safety requirements, ensuring adequate precaution to the neighbourhood structures & equipment, putting necessary cover , and disposal of unserviceable material within station area limit all complete as directed by Site Engineer. Note: 1.Dismantling shall be allowed during day shift only & prior permission for the same shall be obtained. 2. Providing of necessary covers/barricades around the work area is to be done prior to dismantling operations.
Dismantling of structural steel consisting of frames / built up sections in angles, tees, flats, tubes, plates, Joists , channels, , struts, bars etc. at all heights and depths as directed including cutting, welding/ rivets etc., following all safety requirements,ensuring adequate precaution to the neighbourhood structures & equipments, putting necessary cover, dismembering & stacking of all serviceable materials and disposal of unserviceable materials within station area limit as ditrected by Site Engineer inclusive of all labour, material, tools etc. complete.
Earth work in excavation in all kinds of soil except hard rock requiring blasting for foundation trenches, upto any depth including trimming of sides of the trenches, dressing, ramming and levelling the bottom of the trenches correct to level, grade etc. including bailing out of water, if any, filling in sides of foundation trenches, plinth etc. with the excavated earth available and/or depositing the excess earth within station area limits, in layers not exceeding 20 cms. thick, consolidating each deposited layer by ramming, watering, dressing to level and grade , complete in all respects inclusive of cost of all labour, materials, tools, tackles etc. as per drawings, specifications and direction of Site Engineer.
a) Depth upto 1.5 m (measured from original ground level)
b) Depth between 1.5 M to 5 M
Providing and laying cement concrete of mix 1:4:8 (1 cement:4 coarse sand :8 graded stone aggregate 40 mm nominal size) for foundation works at all depths including ramming, dewatering & shuttering etc. complete in all respects inclusive of cost of all labour, materials, tools, tackles etc. as per drawings, specifications and direction of Site Engineer.
Providing and laying cement concrete, grade of mix 1:2:4 (1 cement :2 coarse sand : 4 graded stone aggregate 20 mm nominal size), in foundation, floors, bed of drains, including ramming, de-watering, shuttering, shoring, strutting, curing etc. complete in all respects inclusive of cost of all labour, materials, tools, tackles etc. as per drawings, specifications and direction of Site Engineer.
Supplying and providing reinforcement (for reinforced cement concrete works) Thermo-mechanically treated (TMT) HCR/CRS Fe 500D bars conforming to IS:1786 including initial straightening of coiled/uncoiled bars, removal of loose rust, cutting, bending to correct size & shape, binding with 18 gauge G.I. wire at each intersection and placing at any position, at any height and depth complete in all respects inclusive of cost of all labour, materials, tools, tackles etc. as per drawings, specifications and direction of Site Engineer.
Providing and laying structural reinforced cement concrete work (1:1.5:3) conforming to IS:456 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) at all heights and depth for construction of beams, columns, staircases chajja, roof slabs, facia, canopies, fins, porch, water tank etc. including providing centering, shuttering, staging, scaffolding, form work etc compacting with mechanical vibrator, curing etc. complete in all respects inclusive of cost of all labour, materials, tools, tackles etc. as per drawings, specifications and direction of Site Engineer. (Payment for Reinforcement shall be made as per relevant item of SOR). a) In foundation, plinth,ramps etc. Note: In foundation work, OPC cement with C3A content from 5 to 8%/ PPC/ PSC shall be used .
Providing and laying structural reinforced cement concrete work (1:2:4) conforming to IS:456 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) at all heights and depth for pipe supports etc. including providing centering, shuttering, staging, scaffolding, form work etc compacting with mechanical vibrator, curing etc. complete in all respects inclusive of cost of all labour, materials, tools, tackles etc. as per drawings, specifications and direction of Site Engineer.(Payment for Reinforcement shall be made as per relevant item of SOR). (a) In foundation, plinth, ramps, grade slab etc. Note: In foundation work, OPC cement with C3A content from 5 to 8%/ PPC/ PSC shall be used .
Supplying and providing non-shrinkable cement grout (Shrinkkomp 20 or any other equivalent approved brand) for grouting holding down bolts in pocket holes for equipment foundation, including necessary surface preparation mixing of grout, curing as per manufacturer's recommendation/ specification and direction of the Site Engineer. Note: This item shall be operated under specific instruction of Engineer-in-Charge.
Painting foundation concrete with hot bitumen of grade VG10 @ 17 kg per 10 Sq. mtr. including cleaning the foundation concrete with brushes etc. complete in all respects inclusive of cost of all labour, materials, tools, tackles etc. as per drawings, specifications and direction of Site Engineer.
Supplying and laying flat brick soling in foundation trench, in floors, cable trench etc., with bricks of class designation 50 laid to proper slope, level and grade etc. filling of the joints with sand etc. complete in all respects inclusive of cost of all labour, materials, tools, tackles etc. as per drawings, specifications and direction of Site Engineer.
Brick work with bricks of class designation 50 in cement mortar 1:6 (1 cement : 6 coarse sand) at all heights and depths laid to proper position line, level as per the drawings and specifications including providing necessary scaffolding, staging, raking out of joints, curing etc. complete in all respects inclusive of cost of all labour, materials, tools, tackles etc. as per drawings, specifications and direction of Site Engineer. a) In foundation, plinth etc.
Providing 15 mm thick plaster to internal & external walls at all heights/depths with cement mortar 1:6 (1 cement :6 fine sand) finished smooth/rough including raking out joints, rounding off and chamfering corners, making drip course moulding, roughening of brick surface, curing for etc. complete as per specifications.
Supplying and filling coarse sand under floors, in foundations and plinth including cost-of sand, royalty, transportation, loading , unloading, spreading in layers not exceeding 20 cm., watering, ramming, compacting, dressing and levelling etc. complete in all respects inclusive of cost of all labour, materials, tools, tackles etc. as per drawings, specifications and direction of Site Engineer.
Composite Items-Mechanical works (Rates inclusive of all without GST)
Supplying, fabricating, erecting, placing and fixing in position M.S. structural works using rolled/ built up sections for truss, claddings, bracings, purlins, supporting frames made of joists, tubes, pipes, channels, angles, plates,flats, bars etc. including cutting to required size welding of joints, fixing anchor plates, including bolts, theading, nuts, washers, sleeves etc. including preparation of detailed fabrication drawings & submission to Engineer-in-charge for approval before start of fabrication, supplying & applying painting with two coats of epoxy paint "EPILUX 155 High Build Enamel over a coat of EPILUX 610 Primer of M/s Berger or any other approved equivalent make as per manufacturer’s recommendation, complete in all respects inclusive of cost of all labour, materials, tools, tackles etc. as per drawings, specifications and direction of Site Engineer. (excluding the cost of concrete work).
The job involves removal of existing eqipment alongwith baseframe/supportplate, insulation etc.unfastening,dismantling and transporting of all types of equipments from all elevations such as vessels, heat-exchangers,pumps,mixers etc.with all care to avoid any damage to equipment to the scrap yard/projectstores/mainstores/designated place with all connected structural,variousfittings, instruments installed on the equipment.Job also includes supplying of all types of tools,tackles,lifting arrangements,tractortrolley&equipments,machineries all consumables and labour to complete the job in a work man like manner,erection and removal of steel scaffolding wherever required,area preparation for hot job and area cleaning after completion of work including blinding,deblinding,removal of insulation,gas cutting of bolts,chipping of foundation,flushing wherever required.All jobs are to be carried out as per the instruction and to the full satisfaction of the Engineer-in-Charge
Dismantling of existing over ground piping works of all types and sizes by opening flange joints or by gas cutting/ cold cutting or any other approved suitable means without damaging other portions of work including the booster unit also. The job includes cutting the pipes to required sizes as directed, taking out valves, flanges, tees, bends, gaskets nuts, bolts etc. attached supports alongwith any instruments such as pressure gauge, temperature gauge etc. handling, transporting and storing at owner's designated store in safe manner to avoid damage including supply of all labour, materials, equipments, consumables etc. necessary to perform and complete the work in all respects as per drawings, instructions of the Site Engineer / EIC (payment shall be made on linear measurement of dismantled piping including bends tees etc.).
Hook-up of New Piping with existing Piping by Single Cut/Flange Joint: Cutting of portion of existing piping/ Opening of WNRF/SORF/Blind Flange, trimming, grinding, beveling the edges, aligning with/ without addition of spool piece, welding the joint including supply of all inputs such as labour, materials, equipment, consumables etc. necessary to perform and complete the work in all respect as per specification and instruction of the Site Engineer / EIC. NOTE: The job also include evacuation of product from the piping section after isolating the section and flushing with water and its disposal.
10.75" OD x 0.365" WT
8.625" OD x 0.322" WT
Above ground piping for Process Lines: Taking delivery of pipes,pipe fittings,steel flanges, spiral wound metallic gaskets & fasteners from designated location within station premises, transporting the same to site,fabrication and erection of above ground piping including cutting, edge preparation, bending, threading, liningup, welding and installing pipes and pipe fittings, flanges, elbows, equal and reducing outlet tees,concentric /eccentric reducers,y-type strainers, drain funnels, vent pipes and tapping for instruments such as pressure gauges,thermal relief valves, thermowells etc.,installing aboveground at all elevations connecting with equipment nozzles, valves, vessels, inline instrumentsetc., welded and threaded pipeline of different pressure ratings, flushing pipes by water after cleaning by compressed air, cleaning by cardboard blasting, hydrostatic testing of each section to the specified pressure, draining the water,tie-in,final cleaning-up and dispoal of wastes and surpluses including providing all inputs such as labour, material, equipments and consumables necessary to perform the work (other than those specifically undertaken by the owner in this contract) and completing the work in all respects in accordance with the drawings, specifications and instructions of Site Engineer / EIC.
10.75" OD x 0.250"/ 0.365" APL 5L GR.B / X46 / X52 / X60 / X65 / X70 Pipe
8.625" OD x 0.250"/ 0.322" / 0.375" / 0.438" WT API 5L Gr.B/ASTM A106 / ASTM A 53 Gr. B Pipe
1.315" OD x 0.179"WT ASTM A 106 Gr B
Radiographic Inspection: Inspection of welding by radiographic method on all types of piping including processing of films and interpreting the results of weld quality and reporting the same to the Site Engineer together with recommendations as to the acceptability or otherwise of the welds, submitting the finished radiographic films as may be approved or directed by Engineer-in-Charge inclusive of supply of all pesonnel, labour, materials, equipment, consumable, inputs, etc. and providing all services complete in all respects as envisaged in the contract documents. Note: i) Payment will be on the basis of number of welds of the respective size radiographed and shall be all inclusive for the complete job of radiographic inspection as envisaged in the contract document. ii) Radiography not involving full girth weld will be paid at 50% of the rate for full girth weld for the respective size. iii) For set-on type branch welding, the rate for radiography will be as applicable to the branch pipe size. iv) Repeat radiography of individual welds due to defective films or repair of welds shall be done at contractor's cost.
10" NB Pipe Joints
8" NB Pipe Joints
Installation of Valves: Taking delivery of valves of all types and pressure rating from the designated location within station premises, transporting the same to site, erecting above ground on preconstructed foundations or underground including earth work in excavation and filling for under ground valves at elevations specified in the drawings, priming and painting of above ground valves, flood coating and wrapping of under ground portions (if applicable) including all inputs, labour, material and consumable (other than those specifically undertaken to be supplied by the owner) and completing the work in all respects in accordance with the drawings, manufacturer's installation instructions and specifications and instructions of the Site Engineer / EIC.
12"x ANSI 150# MOV F/F API 6D Gate Valve
8"x ANSI 150# MOV F/F API 6D Gate Valve
8"x ANSI 150 # F/F BS 1868 Swing Check Valve
1"x ANSI 800 Sr. HOV W/W API 602 Gate Valve
Booster Pumping Unit Installation: Taking delivery of booster pumping units having electrical motor & vertical turbine type centrifugal pump and accessories from designated storage location within the pump station, shifting and placing the equipments on the pre-constructed foundation, levelling, grouting and aligning the equipment, assembling together of all sub-assemblies, auxiliaries, mountings, fittings, inter connecting piping etc., carrying out trial run of motor on no load, coupling the electrical motor with the pump, making final alignment, checking and testing of the complete pumping unit and completing the work in all respects in accordance with the specification, drawings, manufacturer's installation instructions, technical specifications and as per the instruction of the Site Engineer / EIC. Note: Electrical & Instrumentation connections are not included in this item.
Booster Pumping Unit (Approx. Maximum Weight 6 tons for 02 nos. of booster)
Above Ground Equipments Installation:Taking delivery of equipments, shifting/transporting within stationpremises, placing on pre-constructed foundations, assembling together all sub-assemblies, levelling, alignment, grouting, cleaning andflushing by water, draining, checking, testing, dressing and making goodof the foundation and completing the work in all respects in accordancewith the relevant drawings, manufacturer's installation instruction,specifications and instructions of Site Engineer / EIC.
Y - Type Strainer-10"x10"-900# (Approx Weight = 1.2 MT x ** Nos. = ***MT at *****)
External surface of BARE EQUIPMENTS AND PIPING with operating temp upto 90 deg c New Construction: Surface Preparation : SA2.5Primer Generic name : Inorganic zinc silicate + epoxy zinc phosphate.DFT : 65 + 25Product name : Tuffkote Ziliplate CGC + epigard zp primer. Intermediate CoatGeneric coat : hb epoxy mioDFT : 75Product name : Epigard hb mio Finish CoatGeneric Name : two pack hb acrylic puDFT : 60 in 2 coats Product Name : shalithane finishTotal DFT : 225
Composite Items-Electrical works (Rates inclusive of all without GST)
Laying of all type of cables LT (PVC / XLPE / Armoured/Unarmoured/Power/ Control/ Signalling) in trenches, in cable racks, in trays, in protective pipes, poles,columns, in conduits, in panels and on structures etc.;including the supply and installation of all required materials such as fixing clamps ,screws, cable straps, tags etc. as required (other than the supply of the conduits, cables, pipes, cable racks, trays, poles, structures and panels) complete in all respect, including cost of all labour, tools, consumable materials etc. and cutting the cables in required lengths as per drawings, specification and directions of Site Engineer / Engineer-in-Charge
(Power cables LT : OD upto 20 mm)
(Power cables LT : OD above upto 40 mm)
Providing end termination of power/control cable including cutting, stripping, providing & fixing heavy duty type lugs, cable insulation, providing & glanding double compression heavy duty brass cable gland conforming to IS-12943 (Dowell's or apporved equivalent),wherever specified, providing heavy duty type aluminium lugs for power cables and copper lugs/ connectors for control cables, crimping/soldering, as necessary, restoration of insulation/ clamping of cable, tagging with aluminium tag, earthing of armour, connection to the equipment terminals etc. all complete with labour and materials as per standard and direction of the Engineer-in-Charge.
3X4 Sqmm
3X50 Sqmm
Erection, installation including within site transportation, testing and commissioning of 415 V , owner supplied power-control- centres, motor control centres , soft starters, APFC panel etc. assembling as required, installation on the already made foundation channels, aligning, levelling, grouting, assembling, making all the inter connections /outgoing/incoming power & control cable/ bus duct connection including making holes for cable entries as required as per drawing, specifications and directions of the Site Engineer/Engineer-in-Charge including cost of all materials, tools labour etc. complete in all respect including termination of all power , control cables, installation of thermistor controller, internal wiring, earthing of LT panels, supply of cable glands etc.complete as per cable schedule, drawings etc. (Weight of unit above 100 kg but upto and including 500 kg)
Upgradation of 35KW to 90KW Feeder along with retrofiting of MCCB and replacement of Bus Bar.
Composite Items-Instrumentation works (Rates inclusive of all without GST)
Taking delivery, shifting within a road distance of 500 meters and installation & testing of Pressure Indicator+ Pressure Switch/Pressure Transmitter (PI+PS/PT) of various ratings by fabrication and installing all the required pipe fittings with pressure pipes, valves, plugs, tees, nipples, junction box, cables etc. Supply and erection of all other required materials such as the, Instrumentation tubing, supporting structure 'clamps, cannopy, screws, nuts, bolts, aluminium sheets, GI wire, steel plates, cement concrete etc. complete in all respeects including supply of suitable 'size non flame proof cable gland at control panel end and terminating the already laid cables at field, junction box and control panel end as per the drawings, specifications and directions of the engineer in-charge/site engineer including cost of all labour, materials, consumables, tools, tackles and services rendered etc. All the instruments shall have to be properly connected to the earth pit through GI wires. The works shall include labelling, tagging using SS plates, glanding and ferruling at both field and panel side. Installation to be completed in all respect.
INSTALLATION OF JUNCTION BOX: Installation of non-flame proof junction box, explosion proof/flameproof 'junction boxes for marshalling of control cables, terminating the cables at field and control panel end, mounting the junction boxes,connecting to earthing grid by supplying and installing all the required materials such as supporting structure, cement concrete, painting, GI wire etc.(excluding supply of the Junction Boxes) in all respects complete as per specifications, drawings and direction of site Engineer including supply of suitable size non-flame proof cable glands at Control Panel end and terminating the already laid cables at field, junction box and control panel end including cost of labour, tools, materials, glanding,ferruling etc. complete in all respects
INSTRUMENTATION JOBS FOR MOV: Carrying out the instrumentation and control system jobs on the already erected actuator assembly of motor operated valves (MOV) by making the necessary cable connection at field and control panel end (excluding the supply of cables) calibrating the control components, adjusting the limit switches, testing the whole assembly as per drawings specifications and direction of the engineer in-charge/site engineer complete in all respect, including supply of suitable size non-flame-proof cable glands, ferruls, drilling/cutting of plate for fixing glands at Control Panel end and terminating the already laid cables at field, junction box and control panel end including cost of all labour, tools,glanding, ferruling, consumables etc.
INSTRUMENTATION JOBS FOR MOTOR BOOSTER PUMPS:Erecting & installing of all instruments such as vibration switch, RTD, level switches etc on the already erected Booster pump unit. Supply, Fabrication and erection ofall pipe fittings as required such as pressure pipes, nipples and valves, plugs, tees and installation & testing, calibration of Instrumentation and control circuit in electrical feeders of Booster Pumping Unit as per directions of Site engineer/Engineer in-charge. Job complete in all respect including cost of all labour, consumables, tools, services rendered etc. including supply and fitting of clamps, screws, nuts, providing assistance to control system vendor in commissioning of booster pumping unit, and supply of suitable size flame proof cable glands and termination of related cables at field, control panel, junction box and MCC panel ends as per scope, mounting of junction boxes, loop testing, cement concrete complete and painting. The work includes labelling,glanding, tagging, ferruling at both ends.
SFI OF GI CABLE TRAY (INCL. COST OF TRAY) : Supply, fabricating and installing following sizes of perforated GI cable trays including horizontal and vertical bends, reducers, tees, cross members and other accessories as required and duly suspended from the ceiling and/or fix to steel/ RCC columns, beams, or any other structure members with MS suspenders, angles, channels etc.complete as per the direction of Engineer-in-Charge
300 mm x 75 mm x 2 mm
150 mm x 75 mm x 2 mm
CABLE LAYING: Laying of Armoured/Unarmoured Control/signalling cables in trenches, in cable racks, in trays, in protective pipes, poles, columns, in conduitsm in panels, in buildings, walls, ceilling and on structures etc. including the supply and installation of all required materials such as fixing clamps, screws, cable straps, tags, GI pipe for cable riser etc. as required ( other than the supply of the conduits, cables, pipes, cable racks, trays, poles, structures and panels) complete in all respect as per specifications, drawings and directions of Site Engineer including cost of all labour, tools, consumable materials etc. and cutting the cables in required lengths.
Cable Diameter less than 20 mm
Cable Diameter between 21 mm to 36 mm.
Associate Infrastructures
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .