Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.6 LAccepted-AOC 01 VILLAGE BABOORI BARARI MATHURA UTTAR PRADESH 281005 | MATHURA | UTTAR PRADESH | 281005 | L1 | Accepted-AOC Awarded | |
| 2 | Not Admitted-Fee/PreQual/Technical 171 GLOBEL SPACE HUDA GLOBEL SPACE COLONY 125055 | SIRSA | HARYANA | 125055 | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification | |
| 3 | Not Admitted-Fee/PreQual/Technical SHOP NO 17 RUGGA MARKET BEHIND CITY NURSING HOME HOSPITAL BHATTU ROAD FATEHABAD 125050 | FATEHABAD | FATEHABAD | HARYANA | 125050 | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| Sl No | Description | Qty | Unit | ASHOK KUMAR L1 |
|---|---|---|---|---|
| 1.00N.S. Item | ||||
| 1.01 | Providing and fixing of Tee, Bend and other material for fitting of flow meters with the existing fitting at STP as required at site as per the satisfaction of Engineer-in-charge | 1 | Each Job | 80,000 ₹80,000 Lowest |
| 2.00 | `Installation and accessories like Cabling as per site requirements, Panel Box etc.. Commissioning Charges of Flow Meter, Customization and programming of flow meter, Configurations as per site requirements and making connection with the existing SCADA software / Head Office to the satisfaction of Engineering In-charge, including one year maintenance charges. Complete in all respects including the Connectivity charges to HSPCB, CPCB and PHED etc.Make:- Forbes Marshall, ABB, SCAN, Endress plus Hauser, Cimcon, Endress Hauser, Schumburger, YLB, Yokogawa, Magnetrol, Danfoss, ultraflux, France, GE, Rosemount (Emerson) with 1 year warranty. | 2 | Each Job | 20,000 ₹40,000 Lowest |
| 3.00 | `Supply, Fixing, testing and commissioning of Remote Terminal Unit with power analyzer having inbuilt GSM/GPRS/3G/4G/5G modem. iRTU configuration is 6 Digital inputs, 2 Digital Outputs and 2 Anolog Inputs. iRTU installation inside a panel having isolation transformer. RTU suitable for multi parameter for transferring data to MCS complete in all respect. Complete in all respects including the Connectivity charges to HSPCB, CPCB and PHED Make:- Forbes Marshall, ABB, SCAN, Endress plus Hauser, Cimcon, Endress Hauser, Schumburger, YLB, Yokogawa, Magnetrol, Danfoss, ultraflux, France, GE, Rosemount (Emerson) with 3 year warranty | 1 | Each Job | 30,000 ₹30,000 Lowest |
| 4.00 | `Supply, Installation, testing and commissioning Electromagnetic Flow Meter W:Accuracy Class and Display:± 0.5% of measured flow: 2 Line LCD R:Indicator Converter Type: Remote, field mounted 4:Power Supply: Universal Power Supply 85 to 265VAC@45 to 65 Hz 2:Output:4 to 20mA 2:Communication Interface: RS 485 (MODBUS RTU) 0:Data Logger: Not Applicable N:Cable Entry:1/2``NPT 0450:Sensor Size (mm):400 mm (12``) 3:Pressure Rating(Kg/cm2):16 Kg/cm2 D:Design of the Measuring Sensor: Flanged-DIN 1:Flange Material: CS 2:Sensor Lining: PTFE 6:Electrode Material:SS316 1:Earthing ring: None. With built-in earthing electrode. 4:Measuring Tube:SS304 2:Coil Housing: CS 8:Protection Class for Sensor:IP68 P:Approval:Non Hazardous area Cable L=20 mtrs Complete in all respects including the Connectivity charges to HSPCB, CPCB and PHED etc. Make:- Forbes Marshall / ABB / Schumburger / Endress Hauser / YBL /Yokogawa / Magnetrol/ SCAN Ultrasonic Insertion Danfoss, Cimcon, Endress plus Hauser, ABB, Ultaflux, France, GE, Endress plus Hauser, Rosemount (Emerson), ABB. (For Inlet) with 3 year warranty. | 1 | Each Job | 3,00,000 ₹3,00,000 Lowest |
| 5.00 | Supply, Installation, testing and commissioning Electromagnetic Flow Meter W:Accuracy Class and Display:± 0.5% of measured flow: 2 Line LCD R:Indicator Converter Type: Remote, field mounted 4:Power Supply: Universal Power Supply 85 to 265VAC@45 to 65 Hz 2:Output:4 to 20mA 2:Communication Interface: RS 485 (MODBUS RTU) 0:Data Logger: Not Applicable N:Cable Entry:1/2``NPT 0450:Sensor Size (mm):450 mm (12``) 3:Pressure Rating(Kg/cm2):16 Kg/cm2 D:Design of the Measuring Sensor: Flanged-DIN 1:Flange Material: CS 2:Sensor Lining: PTFE 6:Electrode Material:SS316 1:Earthing ring: None. With built-in earthing electrode. 4:Measuring Tube:SS304 2:Coil Housing: CS 8:Protection Class for Sensor:IP68 P:Approval:Non Hazardous area Cable L=20 mtrs Complete in all respects including the Connectivity charges to HSPCB, CPCB and PHED etc. Make:- Forbes Marshall / ABB / Schumburger / Endress Hauser / YBL /Yokogawa / Magnetrol/ SCAN Ultrasonic Insertion Danfoss, Cimcon, Endress plus Hauser, ABB, Ultaflux, France, GE, Endress plus Hauser, Rosemount (Emerson), ABB. (For By Pass) with 3 year warranty. | 1 | Each Job | 3,20,000 ₹3,20,000 Lowest |
| 6.00 | `Supply, Installation, Testing, Commissioning, operation and comprehensive Annual maintenance of effluent quality monitoring system at 9.5 MLD STP Kalanwali Town for online (continuous) measurement of pH. Total Suspended Solids (TSS) Chemical Oxygen Demand (COD), Biological Oxygen Demand (BOD) by single analyzer with various sensors (spectral measurement in the UV-VIS range 2000-720 mm) performing reagent and chemical free analysis with automatic cleaning of sensor, single cable and power cables, local data acquisition and display of data on continuous basis for up linking the data to CPCB, HSPCB, PHED, TUV, approved complete in all respect as per central pollution control board (CPCB) guideline for online continuous monitoring system for effluents and as contained in scope of work in the notice inviting tender complete description as per NS item No. 1 of approved DNIT. a) Multi- parameter measuring convertor, for connecting up to 18 intelligent sensors. Scope including 8 analog input/output (4 input and 4 output) (0/4-20m A), wide range power supply optical COD/BOD and TSS probe with spectral processing of the UV VIS range, for measurement in the outlet/effluent/ of municipal waste water treatment plant of 9.5 MLD STP at Kalanwali town with integrated with automatic cleaning. b) Robust digital pH/ORP sensor for p/H/ORP electrodes, with built-in pre- amplifier and temperature sensor with automatic temperature compensation (ATC) cable length 100 meter (minimum).` `c) Sensor adapter cable for all intelligent sensors, with IP68 water proof connection to be intelligent sensors net system) cable length 100 meter (minimum). d) Data transfer to CPCB , HSPCB and PHED servers during 4 years of O and M after commissioning after 3 month trial period (including 4 years of defect liability period ) e) Providing GSM 3G, 4G, 5G modem with mobile network charge for 4 years of O and M after 3 month trial period (including 4 years of defect liability period) Complete in all respects including the Connectivity charges to HSPCB, CPCB and PHED etc. Make:- Lvibond / Systeronics / HATCH / ELICO / Tata Honey Well / Lectro Tex / Aplav / Plico / Systeronics / Forbes Marshall / Polymetron / SWAN / SCAN/ Analytical Instruments / Chemtrols / Dr. Lange / Royce / Endress / Hauser / Hach / Enerson / ABB / Yokogawa / E plus H with 3 year warranty. | 1 | Each Month | 11,00,000 ₹11,00,000 Lowest |
Tender Value
₹19.5 L
EMD Value
₹40,000
Closing Date
24 Sept 2025, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
VIJAY Kumar
Mandi Dabwali PHED
P and F Online Anaysir, Flow Meter, RTU etc.
2025_HRY_472557_1
2025740D013B 5934 465B 8028 BB02B457E48D586PUH
Open Tender
Civil Works
Works
90 days
Kalanwali
2 documents required · 2 mandatory
₹1,000
₹40,000
Yes
15 Oct 2025
16 Sept 2025
24 Sept 2025
16 Sept 2025
24 Sept 2025
16 Sept 2025
Amount
N.S. Item
Providing and fixing of Tee, Bend and other material for fitting of flow meters with the existing fitting at STP as required at site as per the satisfaction of Engineer-in-charge
`Installation and accessories like Cabling as per site requirements, Panel Box etc.. Commissioning Charges of Flow Meter, Customization and programming of flow meter, Configurations as per site requirements and making connection with the existing SCADA software / Head Office to the satisfaction of Engineering In-charge, including one year maintenance charges. Complete in all respects including the Connectivity charges to HSPCB, CPCB and PHED etc.Make:- Forbes Marshall, ABB, SCAN, Endress plus Hauser, Cimcon, Endress Hauser, Schumburger, YLB, Yokogawa, Magnetrol, Danfoss, ultraflux, France, GE, Rosemount (Emerson) with 1 year warranty.
`Supply, Fixing, testing and commissioning of Remote Terminal Unit with power analyzer having inbuilt GSM/GPRS/3G/4G/5G modem. iRTU configuration is 6 Digital inputs, 2 Digital Outputs and 2 Anolog Inputs. iRTU installation inside a panel having isolation transformer. RTU suitable for multi parameter for transferring data to MCS complete in all respect. Complete in all respects including the Connectivity charges to HSPCB, CPCB and PHED Make:- Forbes Marshall, ABB, SCAN, Endress plus Hauser, Cimcon, Endress Hauser, Schumburger, YLB, Yokogawa, Magnetrol, Danfoss, ultraflux, France, GE, Rosemount (Emerson) with 3 year warranty
`Supply, Installation, testing and commissioning Electromagnetic Flow Meter W:Accuracy Class and Display:± 0.5% of measured flow: 2 Line LCD R:Indicator Converter Type: Remote, field mounted 4:Power Supply: Universal Power Supply 85 to 265VAC@45 to 65 Hz 2:Output:4 to 20mA 2:Communication Interface: RS 485 (MODBUS RTU) 0:Data Logger: Not Applicable N:Cable Entry:1/2``NPT 0450:Sensor Size (mm):400 mm (12``) 3:Pressure Rating(Kg/cm2):16 Kg/cm2 D:Design of the Measuring Sensor: Flanged-DIN 1:Flange Material: CS 2:Sensor Lining: PTFE 6:Electrode Material:SS316 1:Earthing ring: None. With built-in earthing electrode. 4:Measuring Tube:SS304 2:Coil Housing: CS 8:Protection Class for Sensor:IP68 P:Approval:Non Hazardous area Cable L=20 mtrs Complete in all respects including the Connectivity charges to HSPCB, CPCB and PHED etc. Make:- Forbes Marshall / ABB / Schumburger / Endress Hauser / YBL /Yokogawa / Magnetrol/ SCAN Ultrasonic Insertion Danfoss, Cimcon, Endress plus Hauser, ABB, Ultaflux, France, GE, Endress plus Hauser, Rosemount (Emerson), ABB. (For Inlet) with 3 year warranty.
Supply, Installation, testing and commissioning Electromagnetic Flow Meter W:Accuracy Class and Display:± 0.5% of measured flow: 2 Line LCD R:Indicator Converter Type: Remote, field mounted 4:Power Supply: Universal Power Supply 85 to 265VAC@45 to 65 Hz 2:Output:4 to 20mA 2:Communication Interface: RS 485 (MODBUS RTU) 0:Data Logger: Not Applicable N:Cable Entry:1/2``NPT 0450:Sensor Size (mm):450 mm (12``) 3:Pressure Rating(Kg/cm2):16 Kg/cm2 D:Design of the Measuring Sensor: Flanged-DIN 1:Flange Material: CS 2:Sensor Lining: PTFE 6:Electrode Material:SS316 1:Earthing ring: None. With built-in earthing electrode. 4:Measuring Tube:SS304 2:Coil Housing: CS 8:Protection Class for Sensor:IP68 P:Approval:Non Hazardous area Cable L=20 mtrs Complete in all respects including the Connectivity charges to HSPCB, CPCB and PHED etc. Make:- Forbes Marshall / ABB / Schumburger / Endress Hauser / YBL /Yokogawa / Magnetrol/ SCAN Ultrasonic Insertion Danfoss, Cimcon, Endress plus Hauser, ABB, Ultaflux, France, GE, Endress plus Hauser, Rosemount (Emerson), ABB. (For By Pass) with 3 year warranty.
`Supply, Installation, Testing, Commissioning, operation and comprehensive Annual maintenance of effluent quality monitoring system at 9.5 MLD STP Kalanwali Town for online (continuous) measurement of pH. Total Suspended Solids (TSS) Chemical Oxygen Demand (COD), Biological Oxygen Demand (BOD) by single analyzer with various sensors (spectral measurement in the UV-VIS range 2000-720 mm) performing reagent and chemical free analysis with automatic cleaning of sensor, single cable and power cables, local data acquisition and display of data on continuous basis for up linking the data to CPCB, HSPCB, PHED, TUV, approved complete in all respect as per central pollution control board (CPCB) guideline for online continuous monitoring system for effluents and as contained in scope of work in the notice inviting tender complete description as per NS item No. 1 of approved DNIT. a) Multi- parameter measuring convertor, for connecting up to 18 intelligent sensors. Scope including 8 analog input/output (4 input and 4 output) (0/4-20m A), wide range power supply optical COD/BOD and TSS probe with spectral processing of the UV VIS range, for measurement in the outlet/effluent/ of municipal waste water treatment plant of 9.5 MLD STP at Kalanwali town with integrated with automatic cleaning. b) Robust digital pH/ORP sensor for p/H/ORP electrodes, with built-in pre- amplifier and temperature sensor with automatic temperature compensation (ATC) cable length 100 meter (minimum).` `c) Sensor adapter cable for all intelligent sensors, with IP68 water proof connection to be intelligent sensors net system) cable length 100 meter (minimum). d) Data transfer to CPCB , HSPCB and PHED servers during 4 years of O and M after commissioning after 3 month trial period (including 4 years of defect liability period ) e) Providing GSM 3G, 4G, 5G modem with mobile network charge for 4 years of O and M after 3 month trial period (including 4 years of defect liability period) Complete in all respects including the Connectivity charges to HSPCB, CPCB and PHED etc. Make:- Lvibond / Systeronics / HATCH / ELICO / Tata Honey Well / Lectro Tex / Aplav / Plico / Systeronics / Forbes Marshall / Polymetron / SWAN / SCAN/ Analytical Instruments / Chemtrols / Dr. Lange / Royce / Endress / Hauser / Hach / Enerson / ABB / Yokogawa / E plus H with 3 year warranty.
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .