Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.6 LAccepted-AOC 23609 A INDERJEET SINGH BATH MANSA ROAD NEAR I T I CHOWK BATHINDA PUNJAB 151001 | BATHINDA | PUNJAB | 151001 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹4.7 L+₹15,500 (3.38%)Rejected-Finance | L2 | Rejected-Finance Rejected | |
| 3 | L3₹5.3 L+₹70,400 (15.3%)Rejected-Finance 36 RANJEET NAGAR SHAHBAD MARKANDA NH 1 KURUKSHETRA HARYANA 136135 | KURUKSHETRA | HARYANA | 136135 | L3 | Rejected-Finance Rejected | |
| 4 | L4₹6.5 L+₹1.9 L (41.1%)Rejected-Finance FCA 560 BLB EAST CHAWLA COLONY SAURAJ SINGH YADAV BALLABGARH VILLAGE TOWN CHAWLA COLONY CITY FARIDABAD FARIDABAD HARYANA 121004 INDIA | FARIDABAD | HARYANA | 121004 | L4 | Rejected-Finance Rejected | |
| 5 | L5₹7.5 L+₹2.9 L (63.1%)Rejected-Finance | L5 | Rejected-Finance Rejected |
Tender Value
₹8.9 L
EMD Value
₹17,880
Closing Date
15 Oct 2024, 6:00 pmClosed
GE Faridkot
GE FARIDKOT MIL STN
Provn of soil testing and investigation for KLP of A Arty Bde Fd Wksp at Faridkot Mil Stn
2024_MES_674887_1
GE FRD-60/2024-25
Open Tender
Civil Works
Item Rate
90 days
GE Faridkot
Category C /K/ L of Group - III and above
9 documents required · 9 mandatory
₹500
GE Faridkot
₹17,880
Yes
25 Nov 2024
17 Sept 2024
22 Oct 2024
17 Sept 2024
15 Oct 2024
1 Oct 2024
Amount
Determination of soil bearing capacity as per IS:1892 (Latest revision) .Bore hole dia shall be 150 mm. Depth of bore shall be decided as per the soil condition and may be taken 15m or N value reaches 50, whichever is earlier. Under this test following results also be provided : (i) Grain size analysis, identification & classification of soil (ii) Unit weight (bulk density), natural moisture content, liquid limit, plastic limit, Shrinkage limit, Plasticity index, specific gravity. (iii) Dry density, degree of saturation of soil (iv) Free swelling index & swelling pressure if expansive soil is encountered. (v) Shear parameters (C-ø analysis). (vi) Consolidation test & permeability test (vii) Depth of water table below ground level (viii) Presence of loose soil, if any and its depth. (ix) If weak soil with lesser N value as specification in table- 1 of IS 1893 (Part-) 2016 is encountered then evaluation of liquefaction potential shall be assessed and remedial action to be adopted shall be specified. (x) SPT test shall be done at 1.0 m interval. (xi) Recommendation for filling under floor and filling under protection including plinth protection. (xii) For open foundation, calculation of net SBC at 1.5 m, 2 m, 2.5 m, 3.0 m from shear as well as settlement criteria. SBC values shall be calculated based on C-ø analysis as well as SPT value. For calculation formula given in IS 6403 shall be used. (xii) If pile foundation are required the depth of pile shall be mentioned and pile capacity in compression, uplift & lateral load shall be given for 300, 400, 450, 500 dia for under reamed piles & for 450, 500, 550, 600 mm dia for long piles. (xiv) Recommendations regarding type of foundation to be adopted & net SBC/pile capacity to be adopted. Also, recommendation shall be given regarding stability of soil and soil stabilization required, if any. (xv) Borehole position duly marked on plan and their distance from adjacent prominent reference points.Plan size of bldgs. shall also be marked in the plan. This plan shall be signed by GE, AGE & soil consultant. (xvi) Colour photograph on A4 size photo paper of the site with th locations of the bore hole duly flagged should be submitted. The photograph should also preferably include any refernce structure and the identification of the same be marked. (xvii) Undisturbed soil sample shall be collected at 1.5 m interval and at change of strata (xviii) K-value of soil 0.5 m depth required in case of swimming pool and water retaining structure (xix) Modulus of subgrade reaction (xx) Direct shear test on disturbed soil sample.
Chemical analysis of soil and recommendation and type of cement to be used for RCC foundation & submission of report in detail .
Chemical analysis of ground water (water to obtained from bottom of bore hole) & submission of report in detail .
Conducting Plate load test for ascertaining SBC at the proposed level of foundation specified for over head reservoir only.
Tri axial shear test on undisturbed soil sample (Unconsolidated undrained,Consolidated undrained, consolidated drained tests) & submission of report in detail . NOTES :-(i) Color photograph on A4 size photo paper of the site with locations of the bore holes duly flagged should be submitted. The photographs should also preferably include any reference structure and the identification of the same be marked. (ii) Soil testing report complete in all respect to be submitted in proper binding form in 06x copies with specific recomendations
National Soil Testing and Research Laboratories (BID ID -3131777)
Rishi Markandeshwar Engineering Consultant (BID ID -3125115)
Shree Balaji Test House Pvt. Ltd. (BID ID -3138384)
KUNIKA GEOTECHNICAL SERVICES P. lTD. (BID ID -3132397)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .