Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.5 LAdmitted-Finance 01 MADHU BHAWAN FIRST FLOOR FLATE NO 01 NAWADIH DHANBAD JHARKHAND 828130 | DHANBAD | JHARKHAND | 828130 | L1 | Admitted-Finance | |
| 2 | Rejected-Technical SAHYOGI NAGAR SECTOR 2 DHANBAD JHARKHAND 826001 | DHANBAD | JHARKHAND | 826001 | - | Rejected-Technical reject | |
| 3 | Rejected-Technical 268 KARGALI BAZAR BERMO BOKARO 829104 JHARKHAND | BOKARO | JHARKHAND | 829104 | - | Rejected-Technical reject |
| Sl No | Description | Qty | Unit | Vedant Enterprises L1 |
|---|---|---|---|---|
| .10 | Supply & Providing float charger having current rating 100A boost cum float charger having rating 100A with associated items like voltmeter for AC volt with voltage selector switch AC main fail relay. Ammeter to read input current with their current transformer & DC voltmeter with four position selector switch to read the voltage of float charger boost cum float charger battery and load with on-off position solid state DC under voltage relay solid state DC battery each fault relay annunciation circuit with Accept/reset/test push button buzzer | 1 | Nos | 5,32,500 ₹5,32,500 Lowest |
| .20 | Lead Acid maintenance free battery Voltage - 2V Capacity - 200 Ah Charging current -21Amps Internal resistance 0.91 milli ohms and 10 Nos of additional spare battery | 65 | Nos | 6,500 ₹4,22,500 Lowest |
| .30 | Supplying and Providing of FRLS PVC insulated armoured control copper conductor 1.1 kV ,single core Multi strand copper cable 8 X 2.5 sqmm for different control connection. | 175 | mtr | 900 ₹1,57,500 Lowest |
| .40 | Supply and Providing of AC/DC Horizontal type distribution Junction box with inbuilt 8 nos of 32 amps MCB per unit with 230v ac power system . | 15 | Nos | 4,500 ₹67,500 Lowest |
| .50 | 110 battery charges panel of sheet steel structure of 2mm thick dust and vermin proof grey colour input and output terminals shall be provided at the bottom of the cabinet with suitable cable entry. Lifting hooks earthing terminal self supportedetc suitable for 150AH 2 volt x55 nos lead acid battery | 1 | Nos | 80,000 ₹80,000 Lowest |
| .60 | Advanced chemical earth pit of length 5 mtr for grounding of boost charger with backfill compound | 3 | Nos | 20,000 ₹60,000 Lowest |
| .70 | Complete Modification of the control circuit with connection with the existing breaker with necessary feruleslugs clips and washer etc and complete testing of the breaker control circuit with the modified input power supply . | 15 | Nos | 5,000 ₹75,000 Lowest |
| .80 | Supply and Providing of remote indication system with alarm for low or voltage and in case of failures | 1 | Nos | 35,000 ₹35,000 Lowest |
| .90 | Complete cleaning and polishing of the bus-bar of different grade . | 1 | job | 1,05,000 ₹1,05,000 Lowest |
| 1.00 | Supply and Providing of advance busbar protection system Preconfigured functions for busbar protection application Used in high-impedance-based applications within utility substations and industrial power systems. In addition, this protection relay can be utilized in restricted earth-fault and residual earth-fault applications for the protection of transformers and reactors. The relays are delivered preconfigured and factory-tested to shorten engineering and commissioning time Self-healing communication based on HSR/PRP using an optional second Ethernet bus With-drawable plug-in unit design | 2 | Nos | 1,30,000 ₹2,60,000 Lowest |
Tender Value
Refer Docs
EMD Value
₹27,800
Closing Date
13 Dec 2025, 6:00 pmClosed
Gautam Mahanty SO(EnM) Dhori Area
Gautam Mahanty SO(EnM) Dhori Area
Renovation of substation by installation and commissioning of float cum boost charger and transformer monitoring system along with reorganization and upgradation of bays in GM Unit Main Sub Station under Dhori Area.
2025_CCL_348566_1
GM(D)/SO(EnM)/NIT/25-26/19
Open Tender
Electrical and Maintenance Works
Item Rate
30 days
Dhori Area
As per NIT
2 documents required · 2 mandatory
₹27,800
19 Dec 2025
2 Dec 2025
15 Dec 2025
3 Dec 2025
13 Dec 2025
3 Dec 2025
3 Dec 2025 - 10 Dec 2025
Amount
Lead Acid maintenance free battery Voltage - 2V Capacity - 200 Ah Charging current -21Amps Internal resistance 0.91 milli ohms and 10 Nos of additional spare battery
Supplying and Providing of FRLS PVC insulated armoured control copper conductor 1.1 kV ,single core Multi strand copper cable 8 X 2.5 sqmm for different control connection.
Supply and Providing of AC/DC Horizontal type distribution Junction box with inbuilt 8 nos of 32 amps MCB per unit with 230v ac power system .
110 battery charges panel of sheet steel structure of 2mm thick dust and vermin proof grey colour input and output terminals shall be provided at the bottom of the cabinet with suitable cable entry. Lifting hooks earthing terminal self supportedetc suitable for 150AH 2 volt x55 nos lead acid battery
Advanced chemical earth pit of length 5 mtr for grounding of boost charger with backfill compound
Complete Modification of the control circuit with connection with the existing breaker with necessary feruleslugs clips and washer etc and complete testing of the breaker control circuit with the modified input power supply .
Supply and Providing of remote indication system with alarm for low or voltage and in case of failures
Complete cleaning and polishing of the bus-bar of different grade .
Supply and Providing of advance busbar protection system Preconfigured functions for busbar protection application Used in high-impedance-based applications within utility substations and industrial power systems. In addition, this protection relay can be utilized in restricted earth-fault and residual earth-fault applications for the protection of transformers and reactors. The relays are delivered preconfigured and factory-tested to shorten engineering and commissioning time Self-healing communication based on HSR/PRP using an optional second Ethernet bus With-drawable plug-in unit design
Supply and Providing of High Sensitive Busbar current transformer of 600/1-1
Supply and Providing of Suitable panel for fixing of bus protection relay with necessary tripping and indication arrangement .
Total impact of GST for the purpose of CTC
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Document
3.24 MB
BOQ
BOQ • 0.24 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .