Loading…
Loading…
Tender ID
Tender Value
Refer Docs
EMD Value
₹5 L
Closing Date
22 May 2026, 2:00 pmClosed
CE LIGHTING
NAGAR NIGAM AGRA
For the purpose of obtaining rates for the supply and installation of LED fittings of various wattages for street lighting within the Municipal Corporation area.
2026_DOLBU_1146550_1
08-05-2026/NAGAR NIGAM LIGHTING/22-05-2026/01
Open Tender
Electrical Works
Item Wise
180 days
AGRA
Please refer Tender documents.
2 documents required · 2 mandatory
₹2,360
NAGAR NIGAM
₹5 L
22 May 2026
8 May 2026
22 May 2026
8 May 2026
22 May 2026
8 May 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply and fixing of LED Street light Fitting with mandatory driver set having die cast aluminium body with toughened glass/ UV stabilized PC Cover and lenses suitable for 45 Watt to 50 Watt confirming to IP 66 and IK07 and above protection having Company LOGO Engraved including labour, Connection wire and cables, GI Bracket, two set of iron clamps as required with 5 years warrantee/ guarantee with replacement as per direction of the Engineer in charge complete in all respects having Specifications as : –
”5400-6000 System Lumen, High Power LED with lenses , 120 L,m/w, PF > 0.95, THD < 10% at full load, CRI> 70, Polled Driver Set in metal housing (Not Circuitry), Phase to Phase Protection at 440 V & > 300 V over voltage auto cut and restart feature, 4 KV internal Surge Protection.” CAT – AAA
(S.I No. 23.14 PWD Schedule 2024) | 1 | NOS | - | - |
| 2 | Supply and fixing of LED Street light Fitting with mandatory driver set having die cast aluminium body with toughened glass/ UV stabilized PC Cover and lenses suitable for 60 Watt to 72 Watt confirming to IP 66 and IK07 and above protection having Company LOGO Engraved including labour, Connection wire and cables, GI Bracket, two set of iron clamps as required with 5 years warrantee/ guarantee with replacement as per direction of the Engineer in charge complete in all respects having Specifications as : –
”7200-8640 System Lumen, High Power LED with lenses , 120 L,m/w, PF > 0.95, THD < 10% at full load, CRI> 70, Polled Driver Set in metal housing (Not Circuitry), Phase to Phase Protection at 440 V & > 300 V over voltage auto cut and restart feature, 4 KV internal Surge Protection.” CAT – AAA
(S.I No. 23.15 PWD Schedule 2024) | 1 | NOS | - | - |
| 3 | Supply and fixing of LED Street light Fitting with mandatory driver set having die cast aluminium body with toughened glass/ UV stabilized PC Cover and lenses suitable for 75 Watt to 90 Watt confirming to IP 66 and IK07 and above protection having Company LOGO Engraved including labour, Connection wire and cables, GI Bracket, two set of iron clamps as required with 5 years warrantee/ guarantee with replacement as per direction of the Engineer in charge complete in all respects having Specifications as : –
”9000-10800 System Lumen, High Power LED with lenses , 120 L,m/w, PF > 0.95, THD < 10% at full load, CRI> 70, Polled Driver Set in metal housing (Not Circuitry), Phase to Phase Protection at 440 V & > 300 V over voltage auto cut and restart feature, 4 KV internal Surge Protection.” CAT – AAA
(S.I No. 23.16 PWD Schedule 2024) | 1 | NOS | - | - |
| 4 | Supply and fixing of LED Street light Fitting with mandatory driver set having die cast aluminium body with toughened glass/ UV stabilized PC Cover and lenses suitable for 100 Watt to 130 Watt confirming to IP 66 and IK07 and above protection having Company LOGO Engraved including labour, Connection wire and cables, GI Bracket, two set of iron clamps as required with 5 years warrantee/ guarantee with replacement as per direction of the Engineer in charge complete in all respects having Specifications as : –
”13200-15600 System Lumen, High Power LED with lenses , 120 L,m/w, PF > 0.95, THD < 10% at full load, CRI> 70, Polled Driver Set in metal housing (Not Circuitry), Phase to Phase Protection at 440 V & > 300 V over voltage auto cut and restart feature, 4 KV internal Surge Protection.” CAT – AAA
(S.I No. 23.17 PWD Schedule 2024) | 1 | NOS | - | - |
| 5 | Supply and fixing of LED Street light Fitting with mandatory driver set having die cast aluminium body with toughened glass/ UV stabilized PC Cover and lenses suitable for 140 Watt to 150 Watt confirming to IP 66 and IK07 and above protection having Company LOGO Engraved including labour, Connection wire and cables, GI Bracket, two set of iron clamps as required with 5 years warrantee/ guarantee with replacement as per direction of the Engineer in charge complete in all respects having Specifications as : –
”16800-18000 System Lumen, High Power LED with lenses , 120 L,m/w, PF > 0.95, THD < 10% at full load, CRI> 70, Polled Driver Set in metal housing (Not Circuitry), Phase to Phase Protection at 440 V & > 300 V over voltage auto cut and restart feature, 4 KV internal Surge Protection.” CAT – AAA
(S.I No. 23.18 PWD Schedule 2024) | 1 | NOS | - | - |
| 6 | Supply and fixing of LED Street light Fitting with mandatory driver set having die cast aluminium body with toughened glass/ UV stabilized PC Cover and lenses suitable for 160 Watt to 175 Watt confirming to IP 66 and IK07 and above protection having Company LOGO Engraved including labour, Connection wire and cables, GI Bracket, two set of iron clamps as required with 5 years warrantee/ guarantee with replacement as per direction of the Engineer in charge complete in all respects having Specifications as : –
”19200-21000 System Lumen, High Power LED with lenses , 120 L,m/w, PF > 0.95, THD < 10% at full load, CRI> 70, Polled Driver Set in metal housing (Not Circuitry), Phase to Phase Protection at 440 V & > 300 V over voltage auto cut and restart feature, 4 KV internal Surge Protection.” CAT – AAA
(S.I No. 23.19 PWD Schedule 2024) | 1 | NOS | - | - |
| 7 | Supply & fixing of factory wired intergal LED flood light luminaries with die cast aluminum housing built with driver set suitable for 100Watt. To 120Watt confirming to IP 66 and IK07 and above protection having Company LOGO Engraved including labour, Connection wire and cables, GI Bracket, two set of iron clamps as required with 5 years warrantee/ guarantee with replacement as per direction of the Engineer in charge complete in all respects having Specifications as : –
”12000-14400 System Lumen, High Power LED with lenses , 120 L,m/w, PF > 0.95, THD < 10% at full load, CRI> 70, Polled Driver Set in metal housing (Not Circuitry), Phase to Phase Protection at 440 V & > 300 V over voltage auto cut and restart feature, 4 KV internal Surge Protection.” CAT – AAA
(S.I No. 23.24 PWD Schedule 2024) | 1 | NOS | - | - |
| 8 | Supply & fixing of factory wired intergal LED flood light luminaries with die cast aluminum housing built with driver set suitable for 140Watt. To 150Watt confirming to IP 66 and IK07 and above protection having Company LOGO Engraved including labour, Connection wire and cables, GI Bracket, two set of iron clamps as required with 5 years warrantee/ guarantee with replacement as per direction of the Engineer in charge complete in all respects having Specifications as : –
”16800-18000 System Lumen, High Power LED with lenses , 120 L,m/w, PF > 0.95, THD < 10% at full load, CRI> 70, Polled Driver Set in metal housing (Not Circuitry), Phase to Phase Protection at 440 V & > 300 V over voltage auto cut and restart feature, 4 KV internal Surge Protection.” CAT – AAA
(S.I No. 23.25 PWD Schedule 2024) | 1 | NOS | - | - |
| 9 | Supply & fixing of factory wired intergal LED flood light luminaries with die cast aluminum housing built with driver set suitable for 170Watt. To 200Watt confirming to IP 66 and IK07 and above protection having Company LOGO Engraved including labour, Connection wire and cables, GI Bracket, two set of iron clamps as required with 5 years warrantee/ guarantee with replacement as per direction of the Engineer in charge complete in all respects having Specifications as : –
”20400-24000 System Lumen, High Power LED with lenses , 120 L,m/w, PF > 0.95, THD < 10% at full load, CRI> 70, Polled Driver Set in metal housing (Not Circuitry), Phase to Phase Protection at 440 V & > 300 V over voltage auto cut and restart feature, 4 KV internal Surge Protection.” CAT – AAA
(S.I No. 23.26 PWD Schedule 2024) | 1 | NOS | - | - |
stage.html
html • 0.01 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.98 MB
BOQ_2144274.xls
BOQ • 0.27 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .