Loading…
New: tenders and results on WhatsApp
New: Find tenders, results and companies on WhatsApp, by text or voice note
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹40.6 LAccepted-AOC SIMBAL CAMP WARD NO 5 NEAR GURUDWARA SAHIB R S PURA DISTT JAMMU J K 1812104 | R S PURA | JAMMU | J K | 1812104 | L1 | Accepted-AOC L1 | |
| 2 | L2₹46.1 L+₹4.9 L (11.9%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN L1 | |
| 3 | L3₹48.4 L+₹7.2 L (17.6%)Rejected-Finance NEAR MES FILTER PLANT SANGOOR UDHAMPUR J K 182101 | UDHAMPUR | UDHAMPUR | J K | 182101 | L3 | Rejected-Finance OTHER THAN L1 | |
| 4 | L4₹49.9 L+₹8.8 L (21.3%)Rejected-Finance HOUSE NO 108 WARD NO 08 SHAKTI NAGAR DHAR ROAD UDHAMPUR UDHAMPUR JAMMU KASHMIR 182101 | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L4 | Rejected-Finance OTHER THAN L1 |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
10 Dec 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (Utilities) Udhampur
GE (Utilities) Udhampur, PO-GARHI, PIN-182121
Repair/Maintenance Wks of E/M installations under AOR of RAC Section under GE (Utilities) Udhampur
2024_MES_682718_1
GE/U- -2024-25
Open Tender
Miscellaneous Works
Item Rate
180 days
GE (Utilities) Udhampur
AS PER NIT
8 documents required · 8 mandatory
₹500
GE (Utilities) Udhampur
₹90,000
14 Jan 2025
7 Nov 2024
17 Dec 2024
7 Nov 2024
10 Dec 2024
21 Nov 2024
Amount
M & L for carrying out following Onsite Tests for 33/11 KV Power transformer of capacity 3.15 MVA Transformer with required / suitable testing equipment by Qualified and Licensed Personal, Recording Test Results and submitted to GE to keep on record duly signed, complete all as specified and as directed by Engineer-in-Charge. [a] IR Test [b] PI [c] Magnetic Balance Test [d] Ratio test [e] Di-electric Test of Oil [f] Short Circuit Test [g] Winding Resistance
M & L for repairing & servicing of 33 KV Isolator including carrying out following activities, complete all as specified and as directed by Engineer-in-Charge. [a] Cleaning of contact for dust, oxidation & pitting with CTC. [b] Cleaning of all insulators with CTC and observing any cracks and carbon deposits / contents. [c] Repairing, adjusting the rotating arms for perfect operation including lubrication with Petroleum Jelly [d] Repairing / Replacement of Tension Spring in Fixed Contacts. [e] Lubricating of all moving parts for smooth operation. [f] Checking of Auxiliary Contacts and their Calibration [g] Applying Petroleum Jelly to all Electrical Contacts / Moving Contacts. [h] Tightening of all Electrical and Mechanical Connections. Note: The rate quoted is deemed to be inclusive of Consumables like nuts & bolts, washers, petroleum jelly, CTC, T & P etc. complete and necessary safety measures for working in 33 KV Yard.
S & F in replacement Silica Gel into Breather of Transformers, complete all as specified and as directed by Engineer-in-Charge.
M & L for Repairs / Servicing of 33 KV SF6 circuit breaker Indoor type with breaking cap 31.5KA having nominal system voltage 33 KV & rated voltage 33 Kv 50Hz, 3 Poles(G.O) out-door interrupting Cap, rated normal current 1250 A, having 2 trip coils auxiliary contacts 12 NO & 12 NC, closing coil 1 No. Arcing time 25 milliseconds, Tripping & closing control circuit voltage 110V DC and spring operated mechanism of ABB make comprising of the following, complete all as specified and as directed by Engineer-in-Charge. [a] Cleaning of Interrupter Limbs for Dust, Oxidising and Decarbonising with CTC. [b] Repair / Servicing of Spring Loaded Operating Mechanism [c] Repair / Servicing of Spring Charging Motor [d] Checking, repairing & servicing of Gearbox, Auxiliary Switches, Spring, Limit Switch etc. complete [e] Checking & Repairing Electrical and Mechanical Operations [f] Checking & Repairing Remote Closing and Tripping of SF6 bracker from Control Panel. [g] Lubrication all Moving Parts with Petroleum Jelly & cleaning all Bushing Insulators with CTC [h] Tightening of all Mechanical Connections of Mechanism [i] Tightening of all HV and LV Connection. Note: Spares required for Servicing / Repairing of SF6 bracker shall be measured and separately under respective items of this BoQ at supply only rates.
M & L for Repairs / Servicing of 12 KV VCB Indoor type with hallow porcelain insulated porcelain clad VCB having nominal system voltage 11 KV highest system voltage 11 KV interrupting capacity rated normal current 1250A, frequency 50Hz, short circuit current 20KA, control circuit voltage 110V DC, of Crompton Greaves make and comprising of the following, complete all as specified and as directed by Engineer-in-Charge. [a] Cleaning of Vacuum Interrupter Limbs for Dust, Oxidising and Decarbonising with CTC. [b] Repair / Servicing of Spring Loaded Operating Mechanism [c] Repair / Servicing of Spring Charging Motor [d] Checking, repairing & servicing of Gearbox, Auxiliary Switches, Spring, Limit Switch etc. complete [e] Checking & Repairing Electrical and Mechanical Operations [f] Checking & Repairing Remote Closing and Tripping of VCB from 33KV Control Panel. [g] Lubrication all Moving Parts with Petroleum Jelly & cleaning all Bushing Insulators with CTC [h] Tightening of all Mechanical Connections of Mechanism [i] Tightening of all HV and LV Connection of VCB. Note: Spares required for Servicing / Repairing of 11 KV Circuit Breaker shall be measured and separately under respective items of this BoQ at supply only rates.
Supply and fixing in replacement of ACB 4 Pole, 415 V, with Thermal Magnetic Release (Manual Fixed type) of capacity 1600 Amps, complete all as specified and as directed by Engineer-in-Charge. Make : L&T/ABB/Schneider
Supply and fixing in replacement of ACB 4 Pole, 415 V, with Thermal Magnetic Release (Manual Fixed type) of capacity 1250 Amps, complete all as specified and as directed by Engineer-in-Charge. Make : L&T/ABB/Schneider
Supply and fixing in replacement of ACB 4 Pole, 415 V, with Thermal Magnetic Release (Manual Fixed type) of capacity 2000 Amps, complete all as specified and as directed by Engineer-in-Charge. Make : L&T/ABB/Schneider
M&L For taking out ACB trolley from LT control panel 415 V 3 phase 2000 Amp , 50 kA, 4 Pole (Make : L&T/ABB/Legrand) and cleaning the ACB with CRC removing all dust , carbon etc greasing the mechanical parts gears ,lever charging male female contacts and spring holders and testing and calibration for overload current and fault current, complete all as specified and as directed by Engineer-in-Charge.
All as per item No. 09.00 here-in-before but for 36KV but for ACB rated current 1600 Amp, 50 KA, 4 Pole, complete all as specified and as directed by Engineer-in-Charge.
All as per item No. 09.00 here-in-before but for 36KV but for ACB rated current 1250 Amp, 50 KA, 4 Pole, complete all as specified and as directed by Engineer-in-Charge.
All as per item No. 09.00 here-in-before but for 36KV but for ACB rated current 800 Amp, 50 KA, 4 Pole, complete all as specified and as directed by Engineer-in-Charge.
Damper suitable for 33 KV Indoor SF6 Breaker of make ABB as per existing model, complete all as specified and as directed by Engineer-in-Charge.
Tripping latch Assembly for 33 KV Indoor SF6 Breaker of make ABB as per existing model, complete all as specified and as directed by Engineer-in-Charge.
Closing latch Assembly for 33 KV Indoor SF6 Breaker of make as per existing model, complete all as specified and as directed by Engineer-in-Charge.
Closing coil 110/220V for 33 KV Indoor SF6 Breaker of make ABB as per existing model, complete all as specified and as directed by Engineer-in-Charge.
Triping coil 110/220V for 33 KV Indoor SF6 Breaker of make ABB as per existing model, complete all as specified and as directed by Engineer-in-Charge.
Closing Spring Assembly for 33 KV Indoor SF6 Breaker of make ABB as per existing model, complete all as specified and as directed by Engineer-in-Charge.
Triping Spring Assembly for 33 KV Indoor SF6Breaker of make ABB as per existing model, complete all as specified and as directed by Engineer-in-Charge.
Limit Switch with bracket complete for 33 KV Indoor SF6 Breaker of make ABB as per existing model, complete all as specified and as directed by Engineer-in-Charge.
Supply & fix in replacement following spares suitable for 11 KV Indoor Vacuum Circuit Breaker of Make: Crompton Greaves model No OVB-VBF 11, complete all as specified and as directed by Engineer-in-Charge.
Closing coil 110/220V for 11 KV Indoor VCB of make Crompton Greaves as per existing model, complete all as specified and as directed by Engineer-in-Charge.
Auxillary contact for 11 KV Indoor VCB of make Crompton Greaves as per existing model, complete all as specified and as directed by Engineer-in-Charge.
Charging Spring for 11 KV Indoor VCB of make Crompton Greaves as per existing model, complete all as specified and as directed by Engineer-in-Charge.
L-Liver for 11 KV Indoor VCB of make Crompton Greaves as per existing model, complete all as specified and as directed by Engineer-in-Charge.
main Shaft for 11 KV Indoor VCB of make Crompton Greaves as per existing model, complete all as specified and as directed by Engineer-in-Charge.
Gear Assembly for 11 KV Indoor VCB of make Crompton Greaves as per existing model, complete all as specified and as directed by Engineer-in-Charge.
Triping coil 110/220V for 11 KV Indoor VCB of make Crompton Greaves as per existing model, complete all as specified and as directed by Engineer-in-Charge.
Spring Charging motor 110/220V for 11 KV Indoor VCB of make Crompton Greaves as per existing model, complete all as specified and as directed by Engineer-in-Charge.
Vacuum Intrerruptor for 11 KV Indoor VCB of make Crompton Greaves as per existing model, complete all as specified and as directed by Engineer-in-Charge.
Supply & fix in replacement following spares suitable for 415V, 50 Hz, 2000A/1600A/1250A Indoor Air Circuit Breaker of Make: L&T & ABB model No CN-SC2000s1, CN-SC1600s1,CN-SC1250s1, complete all as specified and as directed by Engineer-in-Charge.
Under Voltage release coil for 415V, 50 Hz, 2000A/1600A/1250A Indoor Air Circuit Breaker of Make: L&T & ABB as per existing model, complete all as specified and as directed by Engineer-in-Charge.
Closing entromagnet for 415V, 50 Hz, 2000A/1600A/1250A Indoor Air Circuit Breaker of Make: L&T & ABB as per existing model, complete all as specified and as directed by Engineer-in-Charge.
Shunt release for 415V, 50 Hz, 2000A/1600A/1250A Indoor Air Circuit Breaker of Make: L&T & ABB as per existing model, complete all as specified and as directed by Engineer-in-Charge.
Auxilliary contact for 415V, 50 Hz, 2000A/1600A/1250A Indoor Air Circuit Breaker of Make: L&T & ABB as per existing model, complete all as specified and as directed by Engineer-in-Charge.
Motor driven energy storage machanisum for 415V, 50 Hz, 2000A/1600A/1250A Indoor Air Circuit Breaker of Make: L&T & ABB as per existing model, complete all as specified and as directed by Engineer-in-Charge.
Operating machanisum for 415V, 50 Hz, 2000A/1600A/1250A Indoor Air Circuit Breaker of Make: L&T & ABB as per existing model, complete all as specified and as directed by Engineer-in-Charge.
Arc Chute for 415V, 50 Hz, 2000A/1600A/1250A Indoor Air Circuit Breaker of Make: L&T & ABB as per existing model, complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in replacement of MCCB 3 Pole, 415 V, fixed type, 100 Amps with breaking capacity 16 KA, complete all as specified and as directed by Engineer-in-Charge. Make : L&T/HPL/Legrand
Supply and fixing in replacement of MCCB 3 Pole, 415 V, fixed type, 125 Amps with breaking capacity 16 KA, complete all as specified and as directed by Engineer-in-Charge. Make : L&T/HPL/Legrand
Supply and fixing in replacement of MCCB 3 Pole, 415 V, fixed type, 160 Amps with breaking capacity 36 KA, complete all as specified and as directed by Engineer-in-Charge. Make : L&T/HPL/Legrand
Supply and fixing in replacement of MCCB 3 Pole, 415 V, fixed type, 200 Amps with breaking capacity 36 KA, complete all as specified and as directed by Engineer-in-Charge. Make : L&T/HPL/Legrand
Supply and fixing in replacement of MCCB 3 Pole, 415 V, fixed type, 250 Amps with breaking capacity 36 KA, complete all as specified and as directed by Engineer-in-Charge. Make : L&T/HPL/Legrand
Supply and fixing in replacement of MCCB 3 Pole, 415 V, fixed type, 400 Amps with breaking capacity 36 KA, complete all as specified and as directed by Engineer-in-Charge. Make : L&T/HPL/Legrand
Supply and fixing in replacement of MCCB 3 Pole, 415 V, fixed type, 630 Amps with breaking capacity 50 KA, complete all as specified and as directed by Engineer-in-Charge. Make : L&T/HPL/Legrand
Supply and installation of 11 KV, single phase, out door oil cooled CT of ratio 400/200/100/5-5 Amp, class 1.0 / 5P10, burden 15 VA, complete all as specified and as directed by Engineer-in-Charge.
Supply and installation of 11 KV single phase out door oil cooled PT of ratio 11 KV/rt3/110 V/rt3/110V/rt3,Class 0.5-3, Burden 50 VA – 50 VA, complete all as specified and as directed by Engineer-in-Charge.
Supply and installation of 415 V, single phase, CT of ratio 500/5-5 Amp, class 1.0 / 5P10, burden 15 VA, complete all as specified and as directed by Engineer-in-Charge.
M&L for servcing of air Handling Unit of capacity upto 6500CFM by opening of both side cover taking out the Fresh air filter cleaning the External & Internal surface of AHU, Primary air filter, wire mesh filter, Tumble Blower fan and re-fixing the side covers head covers after cleaning of evapration coil with chemical including replacing the suitable gasket for the following :(Necessary Nut, Bolts, washers, pickings are included in quoted rate), complete all as specified and as directed by Engineer-in-Charge. :-
All as per Ser item No 38.00 here-in-before but for 24000 CFM
All as per Ser item No 38.00 here-in-before but for 20000 CFM
All as per Ser item No 38.00 here-in-before but for 18000 CFM
All as per Ser item No 38.00 here-in-before but for 15000/16000 CFM
All as per Ser item No 38.00 here-in-before but for 13000 CFM
All as per Ser item No 38.00 here-in-before but for 10000 CFM
All as per Ser item No 38.00 here-in-before but for 7000 CFM to 9000 CFM
Repairing /Servicing and rewinding of motor 3 phase 400-440 volt complete disconnecting the electric supply removing of pully and fan and opening of both end covers taking out Bearings and rotor checking of air gap, checking of rotor field winding, replacement of bearings, greasing fo bearings including rewiring with superior quality copper winding wire insulating material, vanishing binding of winding etc complete all as directed by Engr -in-Charge reassembling, replacing rusted nut, bolts, washers, checking and adjusting the alignment, connecting electric connection for the following, complete all as specified and as directed by Engineer-in-Charge. :-
Electric motor 3 phase 120 /100 HP of AC Plant.
Electric motor 3 phase 50 HP of AC Plant.
Electric motor 3 phase 24 HP to 30 HP of AC Plant.
Electric motor 3 phase 13 HP to 20 HP of AC Plant.
Electric motor 3 phase 7.5 HP to 10 HP of AC Plant.
Electric motor 3 phase upto 5 HP of AC Plant.
Decoupling, disconnecting suction line and discharge line taking down from foundation bolts, dismounting from base channels strip opening all parts, derusting, cleaning, overhualing comprising of repairs/replacement of unserviceable parts of pump sets. Reassembling of pump set mounting and fixing on base channel, recoupling of suction & discharge line re-alignment commissioning and testing in respect of centrifugal/multistage pump of capacity 100/120 HP, complete all as specified and as directed by Engineer-in-Charge. Note :(i) Loading/unloading & transportation charges shall be deemed included in the quoted rates. (ii) S&F of parts shall be measured and paid separately under respective item of sch A.
Supply & Fix parts for single/double/multistage pump of capacity 100/120 HP as per manufacturer's composition of existing make of pump as below, complete all as specified and as directed by Engineer-in-Charge.
Pump impeller made out of existing material Make : Kirloskar/Wilo Mather Platt or equivalent make as approved be GE.
Pump shaft stainless steel shaft complete with check nut and keys
Shaft sleeves
Bearing housing
Tyre coupling/star coupling
Gland cup with nut and bolts
Star coupling
Supply and fixing in replacement of pump/motor bearing No. 7311 series as per existing specification including taking down the old existing bearing, complete all as specified and as directed by Engineer-in-Charge. Make:-SKF/NBC or equivalent make
Supply and fixing in replacement of pump/motor bearing No. 6310 series as per existing specification including taking down the old existing bearing, complete all as specified and as directed by Engineer-in-Charge. Make:-SKF/NBC or equivalent make
Supply and fix in replacement of MS stud bolts of existing size with nuts suitable for pumps and motors of various capacity installed at installations, complete all as specified and as directed by Engineer-in-Charge.
M&L in replacement of Aluminium lugs suitable for 500 Sqmm Copper cable including taking down the existing unserviceable one, complete all as specified and as directed by Engineer-in-Charge.
All as per Ser item No. 52.00 here-in-before but for 300 SQMM
All as per Ser item No. 52.00 here-in-before for 240 SQMM
All as per Ser item No. 52.00 here-in-before for 185 SQMM
All as per Ser item No. 52.00 here-in-before for 120 SQMM
All as per Ser item No. 52.00 here-in-before for 95 SQMM
All as per Ser item No. 52.00 here-in-before for 70 SQMM
All as per Ser item No. 52.00 here-in-before for 50 SQMM
Supply and fix Gland packing type 3 of size 12 mm made of asbustus grip with silicon, complete all as specified and as directed by Engineer-in-Charge.
All as per Ser item No 60 here-in-before but 16 mm thick
All as per Ser item No 60 here-in-before but 18 mm thick
M&L for heat shrinkable type end termination joint kit outdoor type suitable for XLPE insulated HT cable 33000 Volts grade of size 150 Sqmm 3 core complete with jointing material and accessories along with testing after jointing including taking out the old unserviceable joint kit, complete all as specified and as directed by Engineer-in-Charge.
All as per Ser item No. 63.00 here-in-before but for 33KV of size 400 Sqmm 3 core
All as per Ser item No. 63.00 here-in-before but for 11KV of size 120 Sqmm 3 core
All as per Ser item No. 63.00 here-in-before but for 11KV of size 150 Sqmm 3 core
Supply , laying and testing and commissioning of HT Cable XLPE insulated , screened, PVC bedded galvanised steel strip or wire armoured electric power cable ( heavy duty) with aluminium conductor , 33000 volts earthed grade cross sectional area 150 Sqmm 3 core, laid in trenches, through pipe in road crossing, ducts, fixed along poles, complete all as specified and as directed by Engineer-in-Charge. Make : Grandlay/Havells/KEI
M&L for Dehydration including filtration and cleaning of Transformer oil by dehydrating machine incl testing of sample before and after dehydration and filtration and replacement of silica gel, complete all as specified and as directed by Engineer-in-Charge. NOTE:- dehydration machine and testing kit will be provided by the Dept. but transportation of machine is the responsibility of Contractor without any extra cost to the dept. Sample testing will be carried out in the presence of Engr-in-Charge on site.
Supply & Filling /pouring of up to the appropriate level Transformer oil of low viscosity having dielectric strength not less than 60 KV, complete all as specified and as directed by Engineer-in-Charge. NOTE:- Dielectric strength test shall be carried out at site before poring/filling in transformers in the presence of Engr-in-Charge on the site
M&L for 36KV porcelain Post insulator having highest system voltage 36KA. 50Hz short ckt current 25KA, phase to phase distance 1.5M height of insulator 508.00mm used for support ACSR conductor use for interconnection, complete all as specified and as directed by Engineer-in-Charge.
Material and labour for calibration of overcurrent earth fault relay of make Siemens ( model No 7SJ66) as per existing load for earth fault , over current and short circuit ,including setting the relay on required electric load and testing on earth fault and short circuit and over load with the help of relay testing kit for 132KV & 33 KV system, complete all as specified and as directed by Engineer-in-Charge.
M&L PCC 1:3:6 type C-2 (using 40 mm graded crushed stone aggregate) cement concrete in as in foundation filling of pole & stay, complete all as specified and as directed by Engineer-in-Charge.
Supply & Fixing in replacement Lightning arresters expulsion type complete with all fittings, transmission class, discharge capacity 65 kilo amp suitable for 33 KV line, complete all as specified and as directed by Engineer-in-Charge.
Supply , fixing, commissining and testing in replacement of soft starter suitable for 120/100 HP pump set enclosed in panel of existing size and capacity including replacement of UNSV VFD starter with panel, complete all as specified and as directed by Engineer-in-Charge. Make : Schneider (Product Reference - ATS22C25Q)/ ABB/ L&T or equivalent approved make
Supply , fixing, commissining and testing in replacement of Fully automatic star delta motor starter in sheet steel enclosure type HGS series with single phase protection feature motor rating AC 3 phase 415 volts, 50 Hz for motor of capacity 50 HP, complete all as specified and as directed by Engineer-in-Charge. Make-Havells or equivalent in L&T/ABB/ Schneider.
All as per Ser item No 75.00 here-in- before but of size 30 HP, complete all as specified and as directed by Engineer-in-Charge.
All as per Ser item No 75.00 here-in- before but of size 20 HP, complete all as specified and as directed by Engineer-in-Charge.
All as per Ser item No 75.00 here-in- before but of size 10 HP, complete all as specified and as directed by Engineer-in-Charge.
All as per Ser item No 75.00 here-in- before but of size 5.0 HP, complete all as specified and as directed by Engineer-in-Charge.
Carry out servicing from authorised rep or service engineer from the manufacturer of DG set of 1250 KVA,capacity Make : Sterling all as per OEM instructions and directed by Engineer in Charge . Note : All the spare , parts , lubrication oil etc. has been measured and paid saperatly under respective item of schedule
Fuel filter primary and secondary suitable for DG Set capacity 1250 kva, complete all as specified and as directed by Engineer-in-Charge. Cat Part No. P552006 of make Donaldson or equivalent in Feelgaurd, Kirloskar
Supply only lub oil filter body suitable for DG Set capacity 1250 KVA, complete all as specified and as directed by Engineer-in-Charge. Cat Part No. P551604 of make Donaldson or equivalent in Feelgaurd, Kirloskar
Supply only air filter body suitable for DG Set capacity 1250 KVA, complete all as specified and as directed by Engineer-in-Charge. Cat Part No. P551604 of make Donaldson or equivalent in Feelgaurd, Kirloskar
Only Supply of engine oil 15 W 40 in sealed Packing, complete all as specified and as directed by Engineer-in-Charge. Make: Castrol Super /valvolinre or equivalent .
Supply and filling coolent for radiators. K Cool super Plus -50-50 premix.Cat part No.82.020.35.1.25. 25ltrs Packing, complete all as specified and as directed by Engineer-in-Charge. Make : Super Plus or equivalent .
Supply and fixing in replecement of Electronic Microprocessor based controller unit suitable to DG set controlls & commands of 1250 KVA capacity with all listed parameters as per recomendation including testing, complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in replecement Over load relays RTO-3 Type, relays range 90 to 150 Amps, complete all as specified and as directed by Engineer-in-Charge. Make: L & T/Autoix/MDS/SIMEMS
Supply and fixing in replecement Over load relays RTO-3 Type, relays range 75 to 110 Amps, complete all as specified and as directed by Engineer-in-Charge. Make: L & T/Autoix/MDS/SIMEMS OR Equivalent
Supply and fixing in replecement Over load relays MN5 Type, relays range 36 to 60 Amps, complete all as specified and as directed by Engineer-in-Charge. Make: L & T/Autoix/MDS/SIMEMS
Supply and fixing in replecement of 12 Amp,4pole, 415 Volts, 50 Hz Power contactor (MO12) auxilary contact 2 NO + 2 NC, of coil voltage 240 Volts, complete all as specified and as directed by Engineer-in-Charge. Make:Model No MO 12 of L&T/Schineider/Havells
Supply and fixing in replecement of 110 Amp,4pole, 415 Volts, 50 Hz Power contactor (MO110) auxilary contact 2 NO + 2 NC, of coil voltage 415 Volts, complete all as specified and as directed by Engineer-in-Charge. Make:Model No MO110 of L&T/Schineider/Havells
Supply and fixing in replecement of 70 Amp Actuator relay for 1250 KVA DG set, complete all as specified and as directed by Engineer-in-Charge. Make:Model as per existing OR Equivalent
Supply and fixing in replecement of space heating coil of 5 KV, suitable for 415 Volt, 50Hz, complete all as specified and as directed by Engineer-in-Charge.
Taking out old existing unserviceable thermostate and supply and fix new thermostate for AHU temperature range 30°C- 50°C (as per sample approved by GE), complete all as specified and as directed by Engineer-in-Charge.
Supply, laying, jointing and testing XLPE insulated, PVC outer sheathed, galvanised steel strips armoured, heavy duty power cable with aluminium conductor suitable for rated voltage of 1100 Volts grade earthed system and conforming to IS : 7098 of 1995 and of size 3.5 core X 35 Sqmm and laid in trenches/ducts/pipe or on poles, complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing Electronic Actuator relay for rapid control ,size-22 MN, 48V AC/DC, suitable for 1250 KVA DG set, complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing single phase preventor for 3 phase supply, complete all as specified and as directed by Engineer-in-Charge.
M & L for wiring with FRLS grade PVC insulated unsheathed multistranded copper conductor cables in PVC casing caping of 1.5 sqmm size alongwith one earth continuity conductor with PVC insulated unsheathed multistranded copper conductor cable of 1.5 sqmm for fixing of switches, sockets, light, fan regulators etc for the following, complete all as specified and as directed by Engineer-in-Charge. :-
One light/fan/ /bell point or one fan point controlled by one switch, complete all as specified and as directed by Engineer-in-Charge.
One socket outlet 5 Pin, 5 Amps, SP on same board, complete all as specified and as directed by Engineer-in-Charge.
S&F Piano type switch one way 6 Amps, 240 Volt, ISI marked, complete all as specified and as directed by Engineer-in-Charge.
S&F Switch Piano type single pole 15Amps one way 240 Volt, ISI marked, complete all as specified and as directed by Engineer-in-Charge.
S&F MCB single pole and neutral, 240 Volts, 50 Hz 10 Ka, 40 Amps, complete all as specified and as directed by Engineer-in-Charge.
S&F MCB single pole 240 Volts, 6 to 20 Amps, complete all as specified and as directed by Engineer-in-Charge.
S&F MCB TPN/ FP 415 Volt 16 to 32 Amp 'B' curve, complete all as specified and as directed by Engineer-in-Charge.
Condenser/capacitor suitable for 230 volts singls phase ceiling fan 1200mm/1400 sweep of approved make and quality of capacity 2.5 MFD, complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement LED lights fitting 1x 20W, 220V,AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete making all connection using 1.5 sqmm copper conductor multistrandard PVC insulated 2 core flexible cable with flexible PVC pipe from ceiling rose to fittings, complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in replacement LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size, complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing round shape 15 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size, complete all as specified and as directed by Engineer-in-Charge.
PROACH ASSOCIATES BUILDERS & ENGINEERS (BID ID -3181256)
FANGALIA TRADERS (BID ID -3185852)
slathia construction works (BID ID -3185883)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .