Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹32.7 LAccepted-AOC 53 HOUSING BOARD COLONY PHASE II UDHAMPUR 182101 J K | UDHAMPUR | UDHAMPUR | J K | 182101 | L-1 | Accepted-AOC Being L-1 | |
| 2 | L-2₹34.7 L+₹2.0 L (6.02%)Rejected-Finance | L-2 | Rejected-Finance other than L-1 | |
| 3 | L-3₹37.7 L+₹5.0 L (15.3%)Rejected-Finance 6 RAILWAY STATION ROAD ONKAR INDUSTRIES GULAMALI PURA BAHRAICH UTTAR PRADESH 271801 | BAHRAICH | UTTAR PRADESH | 271801 | L-3 | Rejected-Finance other than L-1 | |
| 4 | L-4₹39.2 L+₹6.5 L (19.7%)Rejected-Finance NEAR MES FILTER PLANT SANGOOR UDHAMPUR J K 182101 | UDHAMPUR | UDHAMPUR | J K | 182101 | L-4 | Rejected-Finance other than L-1 |
Tender Value
₹37.6 L
EMD Value
₹75,200
Closing Date
26 Feb 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Sh A K Dubey IDSE SE CWE
Military Engineer Services, Commander Works Engineer, Udhampur, PO - Garhi, Udhampur-182121
SPL REPAIR TO HT FEEDERS I AND II OF CPH FROM MPH UNDER GE (UTILITY) UDHAMPUR
2022_MES_499975_2
CA NO CWE/U(U)-89/2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
UDHAMPUR
AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
GE (UTILITY) UDHAMPUR
₹75,200
Yes
10 Mar 2022
7 Feb 2022
28 Feb 2022
7 Feb 2022
26 Feb 2022
14 Feb 2022
60 days
Amount
Taking down the Corroded / deteriorated HT Poles ( 11 Mtrs) from the existing electrical network system of ( Central Power House to MPH Substation and MPH to CPH Substation ) any location . Supply, erect, test and commissiong of Steel tubular poles swaged type complete with cast iron base plate , finial taper plugs, bolts, nuts and screws as specified type 410-SP-55 (11 Mtr long) complete all as specified and as directed by Engr-in-Charge. Note : a) Test certificate of Steel tubular pole shall be submitted to department before installation at site.
Taking down the unserviceable iron acessories from pole structures. Supply and fix cross arms, bracings, supports , clamps and back plate fabricated from structural steel sections including nuts, bolts , washers , welding, bending cold or hot , drilling holes for bolts in any shape or size as indicated or directed and inclusive of Scraping out wornout old paint and making the surface smooth, Painting the pole and all MS work mounted on pole with two coats of synthetic enameled paint (Aluminium shade) over a coat of red oxide zinc chrome primer as directed by Engr-in-charge and Forming five nos coloured bands at lower portion of pole each 300 mm wide alternatively with white and black colour (or any colour as approved by Engr-in-charge) synthetic enameled paint and marking pole no. with black and white paint complete all as specified & directed by Engineer-in-charge.
Taking down the unserviceable insulators from 2/4 pole structures .Supply and fix Pin/ Disc/ Shackle of Porcelain category, vitreous ( Colour: White/ browm/ green) insulator including one galvanised mild steel spindle, Two galvanised iron washer and one galvanised iron nut 150mm height, 150 mm dia for 11000 volts grade complete all as specified & directed by Engineer-in-charge.
M & L for providing Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6mm thick buried directly in ground, (Earth pit not less than 2.25 mtr deep below ground level) with top edge of plate not less than 1.5 mtr below normal ground level, connected to galvanized iron earth strip 32x6 mm size by means of bolts, nuts, check nuts and washers of galvanized standard iron or steel all as specified or indicated in electrical plate No 3 of MES Part-I, including testing on completion including the material and labour and taking out old unserviceable earthing of the following :- (a) Excavation and earth work for drilling hole for electrode in any type of soil. (b) PCC pit in cement concrete 1:2:4 type B-1. (c) Precast RCC cover with suitable handle 40 mm thick in PCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than 4 Kg/Sqm. (d) Funnel with watering pipe of GI 20 mm nominal bore medium grade and copper lugs etc all as specified. (e) 40 mm nominal bore light grade GI protection pipe 7.5 mtr long for protection of earthing strip from mechanical injury or tempering. (f) Requisite quantity of common salt and charcoal. (g) Testing of earthing. Note : On testing after completion of earthing, if the desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk and cost to the entire satisfaction of the Engineer-in-Charge.
Taking down the deteriorated aluminium conductor from the existing electrical network system of ( Central Power House to MPH Substation and MPH to CPH Substation ) any location .Supply , lay and stringing of Aluminium conductor reinforced( Rabbit/ Mink/ Skunk ) with steel including various acessories like line connectors , line taps and compression joints wherever required in streaching of conductor complete all as specified & directed by Engineer-in-charge
Taking down/Dismantling of old unserviceable/corroded ACSR Conductor of any size from existing over head lines completed and supply, lay and fix aerial bunched cable 11KV grade stranded and compact aluminium phase conductor of size 3x120 sqmm + 1x70 sqmm (bare messenger) with Aluminium alloy. The phase conductor shall be insulated with XLPE (Sioplas) compound Aluminium as per IS-14225-1995 including all fittings such as anchor clamp, suspension clamp, line connector, service clamp, insulator piercing connectors, for taps from bare line etc. complete all as specified and as directed by Engr-in-Charge.
Taking down the unseviceable Jointing kits from the HT System . Supply and fix cable jointing kit for 11KV (Earthed) grade cable for End joint cold shrinkable type joint outdoor termination complete with jointing material and acessories suitable for 3 core XLPE armoured aluminium conductor cable 120 sq.mm complete all as specified & directed by Engineer-in-charge
Taking down the u/s SF-6 switchgear from the 11 KV system. Supply , install, testing and commissioning of 11KV SF-6 switchgear,630 Amps, 21KA/3 sec, indoor duty internal are IAC AFL 21 KA for 1 sec for Gas tank, SF6 gas insulated , one side extensible 4 way, manual operated ring ment unit. Operated in combination of 1 no load break switchg as incommer and 3 nos load break switch as out goings consisting of copper busbar in SF6 insulated 304(Non-ferrite Non Magnetic grade) complete all as specified & directed by Engineer-in-charge . Stainless steel enclosure of thickness 2.5 mm with manometer fixed. Switchgear shall confirming to IEC-62271-100, IEC-62271-200-2003& IEC 60694-1996. The RMU shall be along the cable chamber to put to an outdoor enclosure to have ingress protection of minimum IP 54. Should have voltage presence indicator and each LBS feeder should have fault passage indicator. Switchgear shall accomodated with syntheic rubber mats 2m x 1 m x 0.5mtrs -01 no each. Note: Old u/s SF6 shall be deposited in AGE E/M E/S store yard with proper ledger charge with JE.
Taking down the unseviceable Jointing kits from the HT System. Supply and fix cable jointing kit for 11KV (Earthed) grade cable for straight through cold shrinkable type joint complete with jointing material and acessories suitable for 3 core XLPE armoured aluminium conductor cable 120 sq.mm complete all as specified & directed by Engineer-in-charge
Taking down the unserviceable HT Cable in the existing electrical network system of ( Central Power House to MPH Substation and MPH to CPH Substation ) any of location . Supply & fix for XLPE insulated, armoured, aluminium conductor cable,PVC bedded, 11000 volts grade, heavy duty, cross sectional area120 sq mm ,3 core, laid in trenches/ducts/through pipe complete all as specified & directed by Engineer-in-charge
Excavation in trenches n exc 1.5 mtr wide and n exc 1.5 mtr in depth for laying of under ground cable and getting out in soft/ loose soil complete all as specified & directed by Engineer-in-charge
Returning filling in excavated soil in trenches including spreading , levelling, watering and well ramming in layers n exc 25 cm thick complete all as specified & directed by Engineer-in-charge
Removing of excavated soil to a distance n exc 50mtr and deposited where directed at a level not exceeding 1.5 mtr above starting point complete all as specified & directed by Engineer-in-charge
Supply and lay DWC (Double wall corruguated) pipe 90/76 mm conforming to IS: 14930/ IS 16205 for protection of HT Cable 120sq.mm, ISI Marked, including necessary snap-fit coupler required for fixing complete all as specified & directed by Engineer-in-charge
Material and labour for road cutting for laying of HT/LT Cables / Pipes and making good the disturbed surfaces as equal to existing road finishes including refilling the excavated material, compacting , WBM and black top carpeting with bitumen & aggregates complete all as specified & directed by Engineer-in-charge
Taking down the u/s AB switches from the 2 pole /4 pole structure from the existing electrical network system of ( Central Power House to MPH Substation and MPH to CPH Substation ) any location . Supply & fix Air breaker switch gang operated triple pole, mechanically operated mounted on insulator and steel frame with operating mechanism worked from ground level, for current rating upto 400 Amps , 11000 volts including drop out fuse set insulators complete all as specified & directed by Engineer-in-charge.
Plain cement concrete (1:3:6 ) type C-2 (using 40mm graded crushed stone aggregate) as in foundation/ mass concrete complete all as specified & directed by Engineer-in-charge.
Providing, cement concrete type B-1, 1:2:4 (using 20mm graded crushed stone aggregate) as in coping of poles including use of form work and finishing all exposed faces of concrete as per clause 4.11.16.2 (a) & (d) of SSR Part-I complete all as specified & directed by Engineer-in-charge.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .