Loading…
Loading…
| # | Company | Amount |
|---|---|---|
| 1 | ₹89.9 Cr H NO 716 A 3 STREET BEHARI GANJ AJMER RAJASTHAN 305 001 | ₹89.9 Cr |
Tender Value
₹84.9 Cr
EMD Value
₹84.9 L
Closing Date
31 Jan 2023, 11:00 amClosed
Construction of Residential Accommodation for Faculty & Staff at Institute of Liver and Biliary Sciences (ILBS) at D-1, Vasant Kunj, New Delhi at the risk and cost of previous agency
NBCC/CPG/ILBS/RC/Delhi/2022/348
NBCC/CPG/ILBS/RC/Delhi/2022/348
Open Tender-Domestic
Civil Works General
New Delhi, Delhi
₹1.2 L
₹84.9 L
10 Jan 2023
10 Jan 2023
31 Jan 2023
31 Jan 2023
16 Feb 2023
BILL OF QUANTITY
Construction of Residential Accommodation for Faculty & Staff at Institute of Liver and Biliary Sciences (ILBS) at the risk and cost of previous agency
Code No. DESCRIPTION
SL.NO. UNIT QUANTITY DSR NDSR DSR NDSR
1 EARTH WORK IN EXCAVATION
a NS Credit for sale of earth Cum 45312.44 -116.65 0.00 -5285696.13
Carriage of materials by mechanical transport including loading, unloading and
a 1.1.1 Lime, moorum, building rubbish (for 30 km) Cum 1500.00 354.36 531540.00
Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in
width as well as 10 sqm on plan including getting out and disposal of excavated earth
upto 50 m and lift upto 1.5 m, as directed by Engineer-in-Charge:
Earth work in excavation by mechanical means (Hydraulic excavator) /manual means
over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10
4 2.6 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m,
surface to be levelled and neatly dressed.
Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated
or stacked materials.
Filling available excavated earth (excluding rock) in trenches, plinth, sides of
foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited
layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
(Net consolidated area fill volume will be computed from the initial and final levels.
Volume in slopes, embankments etc. will be computed applying appropriate formula,
as per CPWD specification).
Supplying and filling in plinth with sand under floors, including watering, ramming,
consolidating and dressing complete.
Clearing grass and removal of the rubbish up to a distance of 50 m outside the
periphery of the area cleared.
Felling trees of the girth (measured at a height of 1 m above ground level), including
9 2.33 cutting of trunks and branches, removing the roots and stacking of serviceable
material and disposal of unserviceable material.
a 2.33.1 Beyond 30 cm girth upto and including 60 cm girth each 0.00 295.97 0.00 0.00
b 2.33.2 Beyond 60 cm girth upto and including 120 cm girth each 0.00 1317.64 0.00 0.00
Transplantation of trees
Transplantation of Treess of the girth from 30cm to 150cm including trimming,
10 NS transposting to the prescribed location and replantation at the location including the each 0.00 15677.24 0.00
maintenance of trees up six months.
ANTI TERMITE TREATMENT
Total carried over to summary 24090976.59 -5285696.13
(Rates for all plain cement concrete items described below shall include work from
Basement Level to top of last roof including roof of machine room, Mumty, over head
water tanks and parapets above at all floors and for all heights.
PLAIN CEMENT CONCTRETE
Providing and laying in position cement concrete of specified grade excluding the cost
of centering and shuttering
a 4.1.3 1:2:4 (1 Cement :2 coarse sand : 4 stone aggregate 20 mm ) cum 1543.97 5279.11 8150787.47 0.00
b 4.1.8 1:4:8 (1 Cement :4 coarse sand : 8 stone aggregate 40 mm ) cum 1148.52 4502.23 5170901.20 0.00
Total carried over to summary 13321688.67 0.00
REINFORCED CEMENT CONCRETE WORKS
(Rates for all reinforced cement concrete items described below shall include work
from Basement Level to top of last roof including roof of machine room, Mumty, over
head water tanks and parapets above at all floors and for all heights, required hacking
of the surfaces for smooth plaster. This section covers cast in situ structural and
architectural concrete work).
CEMENT CONCRETE (CAST-IN-SITU)
Providing and laying in position machine batched and machine mixed design mix M-
25 grade cement concrete for reinforced cement concrete work, using cement content
as per approved design mix, including pumping of concrete to site of laying but
excluding the cost of centering, shuttering, finishing and reinforcement, including
admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting
of concrete, improve workability without impairing strength and durability as per
direction of Engineer-in-charge. (Note :- Cement content considered in this item is
@ 330 kg/cum. Excess/ less
cement used as per design mix is payable/recoverable separately).
a 5.33.1 All works upto plinth level Cum 8691.21 6219.03 54050895.73 0.00
ANUJ NAVNEET Digitally signed by ANUJ
CHACHA Date: 2023.01.10
BILL OF QUANTITY
Construction of Residential Accommodation for Faculty & Staff at Institute of Liver and Biliary Sciences (ILBS) at the risk and cost of previous agency
Code No. DESCRIPTION
SL.NO. UNIT QUANTITY DSR NDSR DSR NDSR
b 5.33.2 All works above plinth level upto floor V level Cum 8077.02 7310.49 59046973.94 0.00
Extra for R.C.C./ B.M.C/ R.M.C. work above floor V level for each four floors or part
Extra for providing richer mixes at all floor levels. Note:- Excess/less cement over the
specified cement content used is payable / recoverable separately.
Providing M-30 grade concrete instead of M-25 grade BMC/ RMC. (Note:- Cement
content considered in M-30 is @ 340 kg/cum)
Providing M-35 grade concrete instead of M-25 grade BMC/ RMC. (Note : Cement
content considered in M-35 is @ 350 kg/ cum)
Centering and shuttering including strutting, propping etc. and removal of form for all
a 5.9.1 Foundations, footings, bases of columns, etc. for mass concrete sqm 4747.41 221.51 1051598.79 0.00
Walls (any thickness) including attached pilasters, butteresses, plinth and string
c 5.9.3 Suspended floors, roofs, landings, balconies and access platform sqm 34503.05 538.94 18595073.77 0.00
d 5.9.4 Shelves (Cast in situ) sqm 538.94 0.00 0.00
e 5.9.5 Lintels, beams, plinth beams, girders, bressumers and cantilevers sqm 24838.54 429.30 10663185.22 0.00
f 5.9.6 Columns, Pillars, Piers, Abutments, Posts and Struts sqm 23138.30 570.56 13201788.45 0.00
g 5.9.7 Stairs, (excluding landings) except spiral-staircases sqm 2979.88 483.96 1442142.72 0.00
Extra for additional height in centering, shuttering where ever required with adequate
bracing, propping etc., including cost of de-shuttering and decentering at all levels,
over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan area
to be measured)
Suspended floors, roofs, landing, beams and balconies (Plan area to be measured)
Reinforcement steel
Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing
in position and binding all complete upto plinth level.
a 5.22.6 Thermo-Mechanically Treated bars of grade Fe-500D or more. Kg 954112.18 64.93 61950503.85 0.00
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing
in position and binding all complete above plinth level.
a 5.22A.6 Thermo-Mechanically Treated bars of grade Fe-500D or more. Kg 1166550.27 64.93 75744109.03 0.00
Total carried over to summary 304771877.77 0.00
(Quoted Rates are for all heights, all depths, all levels, including basement to roof
(mumty) & all leads and lifts, including racking curved or circular masonry work,
racking of brick work should be 10mm)
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation
7.5 in foundation and plinth in:
a 6.1.2 Cement mortar 1:6 (1 cement : 6 coarse sand) cum 486.90 4788.29 2331418.40
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation
20 6.4 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :
a 6.4.2 Cement mortar 1:6 (1 cement : 6 coarse sand) cum 524.46 5902.65 3095703.82 0.00
HALF BRICK MASONRY
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class
designation 7.5 in foundations and plinth in :
a 6.12.2 cement mortar 1:4 (1 cement : 4 coarse sand) sqm 95.24 601.70 57305.91 0.00
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class
designation 7.5 in superstructure above plinth level up to floor V level.
a 6.13.2 Cement mortar 1:4 (1 cement :4 coarse sand) sqm 74.78 724.84 54203.54 0.00
Extra for half brick masonry in superstructure, above floor V level for every four floors
or part thereof by mechanical means.
Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third
course of half brick masonry.
Brick work with non modular fly ash bricks conforming to IS:12894, class designation
25 6.34 10 average compressive strength in super structure above plinth level up to floor V
a 6.34.1 Cement mortar 1:4 (1 cement : 4 coarse sand) cum 4512.39 5811.51 26223799.61
Half brick masonry with non modular fly ash bricks of class designation 10,
conformingio IS :12894, in super structure above plinth and upto floor V level.
a 6.45.2 Cement mortar 1 : 4 (1 cement : 4 coarse sand) sqm 15286.29 713.10 10900653.40
Extra for brick work / AAC block masonry / Tile brick masonry in superstructure above
27 6.5 floor V level, for each four floors or part thereof by mechanical means. cum 5279.44 184.04 971628.14 0.00
Total carried over to summary 44939084.43 0.00
FINISHING WORKS
ANUJ NAVNEET Digitally signed by ANUJ
CHACHA Date: 2023.01.10
BILL OF QUANTITY
Construction of Residential Accommodation for Faculty & Staff at Institute of Liver and Biliary Sciences (ILBS) at the risk and cost of previous agency
Code No. DESCRIPTION
SL.NO. UNIT QUANTITY DSR NDSR DSR NDSR
(Quoted Rate shall be for all heights, depths, levels, leads and lifts and to include
providing Recron polyester fibers in cement mortar at junction RCC and brick / AAC
Block walls and all chasing for electrical & plumbing conduits, pipes etc. for internal
and external plaster works).
CEMENT PLASTER (IN FINE SAND)
28 13.1 12 mm cement plaster of mix :
29 13.2 15 mm cement plaster on the rough side of single or half brick wall of mix :
Providing and fixing 24 gauge and 18 mm mesh size chicken wire mesh at junction of
concrete and brickwork and other locations at all heights including cutting to required
size and side laps of minimum 75 mm and fixing in position with cement and nails as
EXTERNAL CEMENT PLASTER
18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1
31 13.12 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster 1:3 (1 cement : 3 sqm 46979.36 323.93 15218024.08 0.00
coarse sand) finished rough with sponge.
CEILING CEMENT PLASTER
32 13.16 6 mm cement plaster of mix :
EXTRA FOR WATER PROOFING COMPOUND
Extra for providing and mixing water proofing material in cement plaster work in
proportion recommended by the manufacturers
Extra for plastering exterior walls of height more than 10 m from ground level for
every additional height of 3 m or part thereof.
Extra for plastering done on moulding, cornices or architraves including neat
finish to line and level:
INTERIOR FINISHING
36 13.37 White washing with lime to give an even shade :
a 13.37.1 New work (three or more coats) sqm 26135.91 22.20 580217.20 0.00
Distempering with low VOC washable distemper of approved brand and manufacture
to give an even shade :
New work (two or more coats) over and including water thinnable priming coat with
Providing and applying white cement based putty of average thickness 1 mm, of
approved brand and manufacturer, over the plastered wall surface to prepare the
surface even and smooth complete.
Applying priming coats with primer of approved brand and
manufacture, having low VOC (Volatile Organic Compound ) content.
With water thinnable cement primer on wall surface
having VOC content less than 50 grams/litre
Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound )
content less than 50 grams/ litre, of approved brand and manufacture, including
applying additional coats wherever required, to achieve even shade and colour.
EXTERIOR FINISHING
41 13.45 Finishing walls with textured exterior paint of required shade :
New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming
coat of exterior primer applied @ 2.20kg/10 sqm
Finishing walls with Premium Acrylic Smooth exterior paint with Silicone
additives of required shade:
Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of
Special primer applied @ 0.75 ltr /10 sqm
Finishing with Deluxe Multi surface paint system for interiors and exteriors using
Primer as per manufacturers specifications :
Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more
a 13.48.2 coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/10 sqm sqm 152.63 101.29 15459.89 0.00
of approved brand and manufacture
44 13.50 Applying priming coat:
With ready mixed aluminium primer of approved brand and manufacture on resinous
wood and plywood
Painting with synthetic enamel paint of approved brand and manufacture to give
an even shade :
a 13.61.1 Two or more coats on new work sqm 1321.80 94.52 124936.54 0.00
46 13.114 Melamine polishing on wood work (one or more coat). sqm 8764.98 86.12 754840.08 0.00
ANUJ NAVNEET Digitally signed by ANUJ
CHACHA Date: 2023.01.10
BILL OF QUANTITY
Construction of Residential Accommodation for Faculty & Staff at Institute of Liver and Biliary Sciences (ILBS) at the risk and cost of previous agency
Code No. DESCRIPTION
SL.NO. UNIT QUANTITY DSR NDSR DSR NDSR
Total to be carried over the summary 72651335.98 500513.79
DOOR & WINDOW WORKS
(Quoted Rates are for all heights, depths, levels, leads and lifts)
ALUMINIUM DOOR & WINDOW
Providing and fixing aluminium work for doors, windows, ventilators and partitions
with extruded built up standard tubular sections/ appropriate Z sections and other
sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash
fasteners of required dia and size, including necessary filling up the gaps at junctions,
i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc.
47 21.1 Aluminium sections shall be smooth, rust free, straight, mitred and jointed
mechanically wherever required including cleat angle, Aluminium snap beading for
glazing / paneling, C.P. brass / stainless steel screws, all complete as per
architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling
and dash fasteners to be paid for separately) :
21.1.1 For fixed portion
Anodised aluminium (anodised transparent or dyed to required shade according to IS:
1868, Minimum anodic coating of grade AC 15)
For shutters of doors, windows & ventilators including providing and fixing hinges/
pivots and making provision for fixing of fittings wherever required including the cost
of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately)
Anodised aluminium (anodised transparent or dyed to required shade according to IS:
1868, Minimum anodic coating of grade AC 15)
uPVC DOOR & WINDOW
Providing and fixing factory made uPVC white colour sliding glazed window above
1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built
roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick
galvanized mild steel section made from roll forming process of required length
(shape & size according to uPVC profile), appropriate dimension of uPVC extruded
glazing beads, uPVC extruded interlocks and uPVC extruded Inline sash adaptor (if
required), EPDM gasket, wool pile, zinc alloy (white powder coated) handle on one
side of extreme panel along with zinc plated mild steel multi point locking having
transmission gear with keeps, zinc alloy (white powder coated) touch lock with hook
(if required for wire mesh panel), stainless steel (SS 304 grade) body with adjustable
double nylon rollers (weight bearing capacity to be 120 kg), G.I fasteners 100 x 8 mm
size for fixing frame to finished wall and necessary stainless steel screws etc. Profile
of frame & sash shall be mitred cut and fusion welded at all corners, including drilling
of holes for fixing hardware's and drainage of water etc. After fixing frame the gap
between frame and adjacent finished wall shall be filled with weather proof silicon
sealent over backer rod of required size and of approved quality, all complete as per
approved drawing & direction of Engineer-in-Charge. (Single / double glass panes,
wire mesh and silicon sealant shall be paid separately).
Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension
i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in
higher side shall be accepted but no extra payment on this account shall be made.
Two track two panels sliding window made of (big series) frame 67 x 50 mm & sash
46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead /
double glazing bead of appropriate dimension. (Area of window above 2.50 sqm upto
Providing and fixing factory made uPVC white colour sliding glazed window upto
1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built
roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick
galvanized mild steel section made from roll forming process of required length
(shape & size according to uPVC profile), appropriate dimension of uPVC extruded
glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy
(white powder coated) touch locks with hook, zinc alloy body with single nylon rollers
(weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame
to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall
be mitred cut and fusion welded at all corners, including drilling of holes for fixing
hardware's and drainage of water etc. After fixing frame the gap between frame and
50 9.147D adjacent finished wall shall be filled with weather proof silicon sealent over backer rod
of required size and of approved quality, all complete as per approved drawing &
direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon
sealant shall be paid separately)
Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension
i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in
higher side shall be accepted but no extra payment on this account shall be made.
Two track two panels sliding window made of (small series) frame 52 x 44 mm & sash
32 x 60 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of
appropriate dimension. (Area of window upto 1.75 sqm)
ANUJ NAVNEET Digitally signed by ANUJ
CHACHA Date: 2023.01.10
BILL OF QUANTITY
Construction of Residential Accommodation for Faculty & Staff at Institute of Liver and Biliary Sciences (ILBS) at the risk and cost of previous agency
Code No. DESCRIPTION
SL.NO. UNIT QUANTITY DSR NDSR DSR NDSR
Providing and fixing factory made uPVC white colour sliding glazed door
comprising of uPVC multi-chambered frame with in-built roller track and sash
extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel
section made from roll forming process of required length (shape & size according to
uPVC profile), appropriate dimension uPVC extruded glazing beads, uPVC extruded
interlock and uPVC extruded Inline sash adaptor (if required), EPDM gasket, wool
pile, zinc alloy (white powder coated) handle with key on one side of extreme panels
along with zinc plated mild steel multi point locking having transmission gear with
keeps, zinc alloy (white powder coated) cresent lock (if required), stainless steel (SS
304 grade) body with adjustable double nylon rollers (weight bearing capacity to be
120 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary
stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion
51 9.147F welded at all corners, including drilling of holes for fixing hardware's and drainage of
water etc. After fixing frame the gap between frame and adjacent finished wall shall
be filled with weather proof silicon sealent over backer rod of required size and of
approved quality, all complete as per approved drawing & direction of Engineer-in-
Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid
Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension
i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in
higher side shall be accepted but no extra payment on this account shall be made.
Two track two panels sliding door made of (big series) frame 67 x 50 mm & sash 46 x
82 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double
glazing bead of appropriate dimension. (Area of door above 2.00 sqm upto 5.00 sqm)
9.147C Providing and fixing factory made uPVC white colour casement/ Casement
cum fixed glazed door comprising of uPVC multichamberedframe, sash and mullion
(where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick
galvanized mild steel section made from roll forming process of required length
(shape & size according to uPVC profile), uPVC extruded glazing beads of
appropriate dimension, EPDM gasket, zinc alloy (white powder coated) 3D hinges and
one handle on each side of panels along with zinc plated mild steel multi point locking
having transmission gear, cylinder with keeps and one side key, G.I fasteners 100 x 8
mm size for fixing frame to finished wall and necessary stainless steel screws, etc.
Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if
required) shall be also fusion welded including drilling of holes for fixing hardware's
and drainage of water etc. After fixing frame the gap between frame and adjacent
finished wall shall be filled with weather proof silicon sealent over backer rod of
required size and of approved quality, all complete as per approved drawing &
direction of Engineer-in-Charge. (Single / double glass panes and silicon sealent shall
be paid separately).
Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension
i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in
higher side shall be accepted but no extra payment on this account shall be made.
Casement door with top hung ventilator with 3D and S.S. friction hinges (400 x 19 x
1.9 mm) made of (big series) frame 67 x 64 mm, sash 67 x 110 mm & mullion 67 x 80
a 9.147C.2 mm all having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing sqm 260.40 7254.07 1888959.83 0.00
bead of appropriate dimension.(Area of door upto 2.50 sqm)
Providing and fixing factory made uPVC white colour fixed glazed
windows/ventilators comprising of uPVC multi-chambered frame and mullion
(where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick
galvanized mild steel section made from roll forming process of required length
(shape & size according to uPVC profile), , uPVC extruded glazing beads of
appropriate dimension, EPDM gasket, G.I fasteners 100 x 8 mm size for fixing frame
to finished wall, plastic packers, plastic caps and necessary stainless steel screws
etc. Profile of frame shall be mitred cut and fusion welded at all corners, mullion (if
required) shall be also fusion welded including drilling of holes for fixing hardware's
and drainage of water etc. After fixing frame the gap between frame and adjacent
53 9.147B finished wall shall be filled with weather proof silicon sealant over backer rod of
required size and of approved quality, all complete as per approved drawing &
direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall
be paid separately).
Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension
i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in
higher side shall be accepted but no extra payment on this account shall be made.
Fixed window / ventilator made of (small series) frame 47 x 50 mm & mullion 47 x 68
a 9.147B.1 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of sqm 456.30 5038.14 2298903.28 0.00
appropriate dimension. (Area upto 0.75 sqm.)
WOODEN DOOR & WINDOW
Providing wood work in frames of doors, windows, clerestory windows and other
frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners
of required dia & length ( hold fast lugs or dash fastener shall be paid for separately).
a 9.1.1 Second class teak wood cum 71.17 101235.69 7204944.06
ANUJ NAVNEET Digitally signed by ANUJ
CHACHA Date: 2023.01.10
BILL OF QUANTITY
Construction of Residential Accommodation for Faculty & Staff at Institute of Liver and Biliary Sciences (ILBS) at the risk and cost of previous agency
Code No. DESCRIPTION
SL.NO. UNIT QUANTITY DSR NDSR DSR NDSR
Providing and fixing 35 mm thick factory made laminated veneer lumber door shutter
conforming to IS : 14616 and TADS 15:2001 (Part B) fixing with butt hinges of
55 9.6 required size with necessary screws, all complete as per directions of Engineer- in-
charge and panelling with panels of : (Note:- Butt hinges and necessary screws shall
be paid separately)
12 mm thick plain grade -1, medium density flat pressed three layer particle board
a 9.6.1 FPT - I or graded wood particle board FPT- I, IS : 3087 marked, bonded with BWP sqm 2545.18 2050.33 5218458.91 0.00
type synthetic resin adhesive as per IS : 848 :
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I)
decorative type, core of block board construction with frame of 1st class hard wood
and well matched teak 3 ply veneering with vertical grains or cross bands and face
veneers on both faces of shutters.
35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth
57 9.23 on all edges of flush door shutters (over all area of door shutter to be measured). sqm 2545.18 312.15 794477.94 0.00
Providing and fixing wooden moulded beading to door and window frames with iron
58 9.40 screws, plugs and priming coat on unexposed surface etc. complete :
9.40.1 2nd class teak wood
Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm
diameter bolts, nuts and wooden plugs and embedding in cement concrete block
30x10x15cm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm
Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel
screws etc. complete :
Providing and fixing bright finished brass tower bolts (barrel type) with necessary
screws etc. complete :
Providing and fixing bright finished brass 100 mm mortice latch and lock with 6 levers
62 9.76 and a pair of lever handles of approved quality with necessary screws etc. complete. each 1409.00 554.26 780952.34 0.00
Providing and fixing bright finished brass hanging type floor door stopper with
necessary screws, etc. complete.
Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised
(anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to
required colour and shade, with necessary screws etc. complete.
a 9.101.1 Single rubber stopper each 1409.00 26.40 37197.60 0.00
Providing & Fixing Chromium plated brass door eye of approved brand &
manufacture of size 35 mm dia suitable for doors upto 40mm thick having clear wide
Providing & Fixing decorative high pressure laminated sheet of plain /
wood grain in gloss / matt/ suede finish with high density protective
surface layer and reverse side of adhesive bonding quality conforming
to IS : 2046 Type S, including cost of adhesive of approved quality.
FD120 Fire rated doors - Painted
Providing and fixing of Hollow metal Insulated fire rated doors as per IS 3614 part-1,
for stability, integrity & insulation. Pressed galvanized steel confirming to IS 277 with
the following specification. Recommended fire door shall be tested to IS 3614 part 2 /
ISO 834-1 Part 1 / BS476 Part 20 & 22, CBRI / Cerifire or third party certified or
equivavelent lab, for maximum rating of 120mins with 30minutes of insulation, in
latched /unlatched condition (if used with deadbolts and pull handles). Labled doors
67 NS with certification shall be with vision glass as a part of complete assembly.
Manufacturer test certificate shall cover doors both single and double leaf and all
doors supplied shall be within the tested specimen, deviation in specification and
sheet thickness other than what is mentioned in the test certificates are not allowed.
Proper label confirming the type of door and the hourly rating is mandatory. Approved
manufacturer Shakti Hormann or approved equivalent.
Door frame shall be single rebate grooved profile of size 125 x 55mm made out of
1.60mm (16gauge) minimum thick galvanized steel sheet. Frames shall be mitered
and field assembled with self tabs. Frames to have inbuild grooved sealing system
and shall be site fitted with fire rated EPDM gasket as standard. All provision should
be mortised, drilled and tapped for receiving appropriate hardware. Frames should
be provided with back plate bracket and anchor fasteners for installation on a finished
plastered masonry wall opening. Frames shall be filled with fire rated puff.
ANUJ NAVNEET Digitally signed by ANUJ
CHACHA Date: 2023.01.10
BILL OF QUANTITY
Construction of Residential Accommodation for Faculty & Staff at Institute of Liver and Biliary Sciences (ILBS) at the risk and cost of previous agency
Code No. DESCRIPTION
SL.NO. UNIT QUANTITY DSR NDSR DSR NDSR
Door leaf shall be 46mm thick fully flush double skin door, insulated with or without
vision lite. Door leaf shall be manufactured from 1.2mm (18guage) minimum thick
galvanised steel sheet. The internal construction of the door should be rigid
reinforcement pads for receiving appropriate hardware. The infill material shall be
high density insulation material. Intumescent seals 15x2mm to be provided all around
the door in addition to the grooved smoke seal. All doors shall be factory prepped for
receiving appropriate hardware and provided with necessary reinforcement for
hinges, locks, and door closers. The edges should be interlocked with a bending
radius of 1.4mm. For pair of doors integrated astragals has to be provided on the
meeting stile for both active and inactive leaf. Vision lite wherever applicable should
be provided as per manufacturers recommendation with a clipon arrangement. The
glass should be 6mm clear borosilicate fire rated glass of relavant rating of the door.
All doors and frames shall be finished Pure Polyster Powder coated and shall have
passed minimum 500 hours of salt sprey test.
Rate shall include supply and installation of door and hardware as a complete
assembly as mentioned in the door and hardware schedule. Once frame installed
should be filled with PUF as recomended by the manufacturer or engineer.
a 120Mins Fire Rated Door insulated 30minutes Single leaf of size Sqm 232.05 6705.94 1556113.38
Providing & fixing of SS Ball Bearing Hinges of size 100 x 75 x 3mm complet with SS
c NS 3 Point panic bar 0.00
d For Double Leaf Door Nos. 65.00 7869.73 511532.45
e NS External lever Handle with locking arrangement Nos. 65.00 2187.50 142187.50
f NS Providing & fixing of door closers of of approved make Nos. 130.00 3686.02 479182.60
Vision Panels 120 mm rating 200mm x 300mm size 6mm thick glass with fixing tapes
h NS Groove seal for frames RM 383.50 194.41 74556.24
Total to be carried over the summary 45149058.83 3122004.26
(Quoted Rates are for all heights, depths, levels, leads and lifts)
Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone
68 11.3 aggregate) finished with a floating coat of neat cement, including cement slurry, but
excluding the cost of nosing of steps etc. complete.
a 11.3.1 40 mm thick with 20 mm nominal size stone aggregate sqm 243.34 387.54 94303.98 0.00
69 11.13 Providing and fixing glass strips in joints of terrazo/ cement concrete floors.
a 11.13.1 40 mm wide and 4 mm thick metre 52.50 metre 29.17 58.44 1704.69 0.00
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by
the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622,
of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1
cement : 4 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including
grouting the joints with white cement and matching pigments etc., complete.
Marble stone flooring with 18 mm thick marble stone, as per sample of marble
approved by Engineer-in-charge, over 20 mm (average) thick base of cementmortar
1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry,including
rubbing and polishing complete with :
a 11.23.1 Makrana white second quality sqm 21012.17 2517.85 52905492.23
Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be
specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved
make, in all colours, hades, except White, Ivory, Grey, Fume Red Brown, laid on 20
72 11.38 mm thick bed of cement mortar 1:4 (1 ement : 4 Coarse sand), jointing with grey sqm 687.40 775.07 532783.12
cement slurry @ 3.3 kg/ sq.m including pointing the joints with white cement and
matching pigments etc., complete.
Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more
(thickness to be specified by the manufacturer), of 1st quality conforming to IS :
15622, of approved make, in colours White, Ivory, Grey, Fume Red Brown, laid on 20
mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), jointing with grey cement
slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching
pigments etc., complete.
Providing and laying Polished Granite stone flooring in required design and
patterns, in linear as well as curvilinear portions of the building, all complete as per
the architectural drawings, with 18 mm thick stone slab over 20 mm (average) thick
74 11.56 base of cement mortar 1:4 (1 cement : 4 coarse sand), laid and jointed with cement
slurry and pointing with white cement slurry admixed with pigment of matching shade,
including rubbing, curing and polishing etc. all complete as specified and as directed
by the Engineer-in-Charge.
Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with
grey cement slurry mixed with pigment to match the shade of the slab, including
rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse
ANUJ NAVNEET Digitally signed by ANUJ
CHACHA Date: 2023.01.10
BILL OF QUANTITY
Construction of Residential Accommodation for Faculty & Staff at Institute of Liver and Biliary Sciences (ILBS) at the risk and cost of previous agency
Code No. DESCRIPTION
SL.NO. UNIT QUANTITY DSR NDSR DSR NDSR
Granite stone slabs 18 mm thick in risers of steps, skirting, dado and pillars laid on
12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with
grey cement slurry mixed with pigment to match the shade of the slabs, including
rubbing and polishing complete.
Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on
12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with
grey cement slurry mixed with pigment to match the shade of the slabs, including
rubbing and polishing complete.
Extra for pre finished nosing in treads of steps of Kota stone/ sand stone slab.
Extra for Kota stone/ sand stone in treads of steps and risers using single length up to
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and
prepolished, machine cut for kitchen platforms, vanity counters, window sills,
facias and similar locations of required size, approved shade, colour and texture laid
80 8.2 over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated
with white cement, mixed with matching pigment, epoxy touch ups, including rubbing,
curing, moulding and polishing to edges to give high gloss finish etc. complete at all
8.2.2 Granite of any colour and shade
Extra for providing opening of required size & shape for wash basin/ kitchen sink in
kitchen platform, vanity counter and similar location in marble/ Granite/ stone work,
including necessary holes for pillar taps etc. including moulding, rubbing and polishing
of cut edges etc. complete.
Total carried over to summary 65922297.48 742815.57
FALSE CEILING WORKS
(Quoted Rates are for all heights, depths, levels, leads and lifts)
Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in
true horizontal level, suspended on inter locking metal grid of hot dipped galvanized
steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main
"T" runner with suitably spaced joints to get required length and of size 24x38 mm
made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and
cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long
spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm
and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm
thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form
grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling
82 12.52 tiles of approved texture in the grid including, required cutting/making, opening for
services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T"
runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6
mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI
adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced
at 1200 mm center to center along main T, bottom exposed width of 24 mm of all
Tsections shall be pre-painted with polyester paint, all complete for all heights as per
specifications, drawings and as directed by Engineer-in-charge.
GI Metal Ceiling Lay in plain Tegular edge Global white color tiles of size 595x595
mm, and 0.5 mm thick with 8 mm drop; made of G I sheet having galvanizing of 100
a 12.52.1 gms/sqm (both sides inclusive) and electro statically polyester powder coated of sqm 20.58 1169.92 24076.95 0.00
thickness 60 microns (minimum), including factory painted after bending.
Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in
true horizontal level, suspended on interlocking metal grid of hot dipped galvanized
steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main
"T" runner with suitably spaced joints to get required length and of size 24x38 mm
made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and
cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long
spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm
and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm
thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form
grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling
tiles of approved texture in the grid including, required cutting/making, opening for
services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T"
runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6
mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI
adjustable rods with galvanized butterfly level clips of size 85 x 30 x 0.8 mm spaced
at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-
sections shall be pre-painted with polyester paint, all complete for all heights as per
specifications, drawings and as directed by Engineer-in-charge.
8 mm thick fully perforated calcium silicate board made with Calcareous &
Siliceousmaterials reinforced with cellulose fiber manufactured through autoclaving
processto give stable crystalline structure with minimum compressive strength 225
kg/ sq.cm, bending strength 100 kg/sq. cm , of size 595x595 mm, having perforation
of dia.10 mm with minimum perforated area 18 % with non woven tissue on the back
side,having an NRC ( Noise Reduction Coefficient) of 0.85, with 50 mm thick rockwool
of48 kg /cum backing.
ANUJ NAVNEET Digitally signed by ANUJ
CHACHA Date: 2023.01.10
BILL OF QUANTITY
Construction of Residential Accommodation for Faculty & Staff at Institute of Liver and Biliary Sciences (ILBS) at the risk and cost of previous agency
Code No. DESCRIPTION
SL.NO. UNIT QUANTITY DSR NDSR DSR NDSR
Providing and fixing false ceiling at all height including providing and fixing of frame
work made of special sections, power pressed from M.S. sheets and galvanized with
zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of
angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at
1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm
dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers
of 25x10x0.50 mm of required length with nuts & bolts of required size and other end
of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the
spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom
wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450
mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate
channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at
every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having
84 12.45 flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with
the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm
interval, including fixing of gypsum board to ceiling section and perimeter channel with
the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and
finishing to a flush finish of tapered and square edges of the board with recommended
jointing compound , jointing tapes , finishing with jointing compound in 3 layers
covering upto 150 mm on both sides of joint and two coats of primer suitable for
board, all as per manufacturer's specification and also including the cost of making
openings for light fittings, grills, diffusers, cutouts made with frame of perimeter
channels suitably fixed, all complete as per drawings, specification and direction of
the Engineer in Charge but excluding the cost of painting with :
12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- (Part I) :
2011 (Board with BIS Certification marks)
Providing & fixing false ceiling at all height including providing & fixing
offramework made of special section, power pressed from M.S. sheets
andgalvanised with zinc coating of 120 gms/ sqm (both side inclusive) as per IS :277
and consisting of angle cleat of size 25mm wide x 1.6mm thick with flangesof 27mm
and 37mm, at 1200mm c/c, one flange fixed to the ceiling with dashfastener 12.5mm
dia x 50mm long with 6mm dia bolts, other flange of cleatfixed to the angle hangers of
25 x10 x0.50mm of required length with nuts &bolts of required size and other end of
angle hanger fixed with intermediateG.I chanels 45 x15 x 0.90mm running at the
spacing of 1200 mm c/c, to whichthe ceiling section 0.5mm thick bottom wedge of
80mm with tapered flangesof 26 mm each having lips of 10.5mm, at 450mm c/c, shall
be fixed in a directionperpendicular to G.I intermediate channel with connecting clip
made out of2.64mm dia x 230mm long G.I wire at every junction, including fixing
perimeterchannels 0.50mm thick 27mm high having flanges of 20mm and 30mm
85 12.59 long,the perimeter of ceiling fixed to wall/ partitions with the help of Rawl plugs
at450mm centre, with 25mm long dry wall screws @ 230mm interval, includingfixing
of Calcium Silicate Board to ceiling section and perimeter channels withthe help of dry
wall screws of size 3.5 x25mm at 230mm c/c, including jointing& finishing to a flush
finish of tapered and square edges of the board withrecommended jointing
compounds, jointing tapes,finishing with jointingcompounds in three layers covering
up to 150mm on both sides of joints andtwo coats of primer suitable for boards, all as
per manufacture's specificationand also including the cost of making opening for light
fittings, grills, diffusers,cut outs made with frame of perimeter channels suitably fixed,
all complete asper drawings, specificaton and direction of the Engineer in
charge butexcluding the cost of painting with:
8 mm thick Calcium Silicate Board made with Calcareous & Siliceous
a 12.59.1 materialsreinforced with cellulose fiber manufactured through autoclaving process. sqm 1886.86 989.98 1867953.66 0.00
Total carried over to summary 5680835.23 0.00
(Quoted Rates are for all heights, depths, levels, leads and lifts)
Granite stone slabs 18 mm thick in risers of steps, skirting, dado and pillars laid on
12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with
grey cement slurry mixed with pigment to match the shade of the slabs, including
rubbing and polishing complete.
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622
(thickness to be specified by the manufacturer), of approved make, in all colours,
shades except burgundy, bottle green, black of any size as approved by Engineer-in-
87 8.31 Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar sqm 10729.49 801.20 8596467.39 0.00
1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm,
including pointing in white cement mixed with pigment of matching shade complete.
Total carried over to summary 8596467.39 7836716.29
(Quoted Rates are for all heights, depths, levels, leads and lifts)
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing
88 10.25 in position and applying a priming coat of approved steel primer using structural steel
etc. as required.
In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
Providing and fixing hand rail of approved size by welding etc. to steel ladder railing,
89 10.26 balcony railing, staircase railing and similar works, including applying priming coat
of approved steel primer.
ANUJ NAVNEET Digitally signed by ANUJ
CHACHA Date: 2023.01.10
BILL OF QUANTITY
Construction of Residential Accommodation for Faculty & Staff at Institute of Liver and Biliary Sciences (ILBS) at the risk and cost of previous agency
Code No. DESCRIPTION
SL.NO. UNIT QUANTITY DSR NDSR DSR NDSR
Providing and fixing stainless steel ( Grade 304) railing made of Hollow
tubes,channels, plates etc., including welding, grinding, buffing, polishing and making
curvature (wherever required) and fitting the same with necessary stainless steel nuts
and bolts complete, i/c fixing the railing with necessary accessories & stainless steel
90 10.28 dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the Kg 30942.48 447.49 13846450.38 0.00
side of waist slab with suitable arrangement as per approval of Engineer-in-charge,
(for payment purpose only weight of stainless steel members shall be considered
excluding fixing accessories such as nuts,bolts, fasteners etc.).
Supplying and fixing rolling shutters of approved make, made of required
size M.S. laths, interlocked together through their entire length and jointed together at
the end by end locks, mounted on specially designed pipe shaft with brackets, side
guides and arrangements for inside and outside locking with push and pull operation
complete, including the cost of providing and fixing necessary 27.5 cm long wire
springs manufactured from high tensile steel wire of adequate strength conforming to
IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.
a 10.6.1 80x1.25 mm M.S. laths with 1.25 mm thick top cover Sqm 70.00 2289.45 160261.50 0.00
92 10.7 Providing and fixing ball bearing for rolling shutters. each 10.00 326.49 3264.90 0.00
Extra for providing mechanical device chain and crank operation for
operating rolling shutters.
a 10.8.1 Exceeding 10.00 sqm and upto 16.80 sqm in the area Sqm 30.00 860.50 25815.00 0.00
Extra for providing grilled rolling shutters manufactured out of 8 mm dia
94 10.9 M.S. bar instead of laths as per design approved by Engineer-in- charge, Sqm 5.00 520.20 2601.00 0.00
(area of grill to be measured).
Total carried over to summary 19920078.49 0.00
WATER PROOFING WORKS
(Quoted Rates are for all heights, depths, levels, leads and lifts)
Providing and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with
SRI (solar refractive index) > 78, solar reflection > 0.70 and initial emittance > 0.75 on
waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in
the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white
cement & marble powder in ratio of 1:1, including rubbing and polishing of the surface
upto 3 cuts complete, including providing skirting upto 150 mm height along the
parapet walls in the same manner.
Providing and laying roof insulation with 40 mm thick impervious sprayed, closed
cell free Rigid Polyurethane foam over deck insulation conforming to IS - 12432 Pt. III
(density of foam being 40-45 kg/ cum), over a coat of polyurethane primer applied @
6-8 sqm per litre, laying 400 G polythene sheet over PUF spray and providing a
wearing course of 40 mm thick cement screed 1:2:4 (1 cement : 2 coarse sand : 4
96 12.56 stone aggregate 20 mm nominal size) in chequered rough finish, in panels of 2.5 m x sqm 2679.04 1098.18 2942068.15 0.00
and embedding with 24 G wire netting and sealing the joints with polymerized mastic,
all complete as per direction of Engineer-in-Charge
Providing and fixing of external thermal insulation and composite system with
First layer of self-extinguishing type Expanded Polystyrene (EPS) insulation
boards of 120 mm thick ( max 1mX0.5m section), confirming to IS 4671:1984,
having thermal conductivity of 0.034 W/mK, (measured as per IS 3346-1980),density
of 20-24 kg/m³ measured as per IS 5688-1982, Fire retardant property
self-extinguishing type as per EN 13501-1, bonded with special polymer modified
cementitious adhesive confirming to EOTA ETAG 004 (European Technical
Approval) formulated to bond polystyrene insulation boards to typical mineral
substrate (according to ETAG 004) and Polypropylene mechanical fasteners
with plastic pin confirming to EOTA ETAG 014 (European Technical Approval)
having dia 10mm & L=200mm on finished level wall and the junction between
two adjacent EPS boards to be sealed with low expansion moisture cure
Polyurethane Foam. Second layer consists of Fiberglass mesh covered with
97 26.67 alkali-resistant coating, mass per unit area > 145 gm/m², mesh size: 3.9x4.0 mm sqm 2679.04 2618.01 7013753.51 0.00
±10% embedded in special polymer modified cementitious Base Coat with
hydrophobes and the corners will be protected with Corner-beads with alkaliresistant
mesh wings at least 10 cm wide, mesh mass per unit area min 145 gm/
m². The surface will be levelled, finished, made smooth complete in all respect
as per manufactures specification and as per directions of Engineer-in-Charge.
98 22.14 Grading roof for water proofing treatment with
Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm
ANUJ NAVNEET Digitally signed by ANUJ
CHACHA Date: 2023.01.10
BILL OF QUANTITY
Construction of Residential Accommodation for Faculty & Staff at Institute of Liver and Biliary Sciences (ILBS) at the risk and cost of previous agency
Code No. DESCRIPTION
SL.NO. UNIT QUANTITY DSR NDSR DSR NDSR
Providing and laying water proofing treatment to vertical and horizontal surfaces of
depressed portions of W.C., kitchen and the like consisting of:
(i) 1st course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing
compound conforming to IS 2645 in recommended proportions including rounding off
junction of vertical and horizontal surface.
(ii) 2nd course of 20 mm cement plaster 1:3 (1 cement: 3 coarse sand) mixed with
water proofing compound in recommended proportion including rounding off junction
of vertical and horizontal surface.
(iii) 3rd course of applying blown or residual bitumen applied hot at 1.7kg. per sqm of
(iv) 4th course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should
be 100 mm wide and pasted to each other with bitumen @ 1.7kg/sqm)
Providing and applying integral crystalline slurry of hydrophilic in nature for
waterproofing treatment to the RCC structures like retaining walls of the basement,
water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels /
subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral
crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral
crystalline slurry : 1 part water) for horizontal surfaces and applying the same from
negative (internal) side with the help of synthetic fiber brush. The material shall meet
the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of
concrete by more than 90% compared with control concrete as per DIN 1048 and
resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall
be capable of self-healing of cracks up to a width of 0.50mm. The work shall be
carried out all complete as per specification and the direction of the engineer-
incharge.The product performance shall carry guarantee for 10 years against any
For vertical surface two coats @ 0.70 kg per sqm-Retaining Wall/Water Tank Wall
For horizontal surface one coat @1.10 kg per sqm.-Below Raft/ Water Tank Floor
Providing and laying water proofing treatment on roofs of slabs by applying cement
slurry mixed with water proofing cement compound consisting of applying:
(a) after surface preparation, first layer of slurry of cement @ 0.488 kg/sqm mixed
with water proofing cement compound @ 0.253 kg/sqm.
(b) laying second layer of Fibre glass cloth when the first layer is still green. Overlaps
of joints of fibre cloth should not be less than 10 cm.
(c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/sqm
mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @
101 22.6 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for sqm 7378.32 406.75 3001131.66 0.00
48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked
into groove in parapet all around.
(d) fourth and final layer of brick tiling with cement mortar (which will be paid for
separately.For the purpose of measurement the entire treated surface will be
Extra for covering top of membrane with Geotextile, 120 gsm non woven, 100%
polyester of thickness 1 to 1.25 mm bonded to the membrane with intermittent
102 14.92 touch by heating the membrane by Butane Torch as per manufactures sqm 7378.32 77.57 572336.28 0.00
recommendation.
Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4
103 12.21 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 0.00
(1 cement : 3 fine sand) as per standard design :
Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete
1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size)
over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1
cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making
and finishing the outlet complete.
Total carried over to summary 26972933.97 0.00
MISCELLANEOUS WORKS
Providing & fixing of 50mm thick GRC Jali with necessary supports, as per approved
sample, including all necessary arrangements & hardware- fittings,
105 NS Item fixtures,scaffolding and edge finish etc., complete as per design, details &
specification, or as per directions of Engineer-in-charge.
Total carried over to summary 0.00 4529147.63
ANUJ NAVNEET Digitally signed by ANUJ
CHACHA Date: 2023.01.10
BILL OF QUANTITY
Construction of Residential Accommodation for Faculty & Staff at Institute of Liver and Biliary Sciences (ILBS) at the risk and cost of previous agency
Code No. DESCRIPTION
SL.NO. UNIT QUANTITY DSR NDSR DSR NDSR
Providing and laying C.C. pavement of mix M-25 with ready mixed concrete from
batching plant. The ready mixed concrete shall be laid and finished with screed board
vibrator , vacuum dewatering process and finally finished by floating, brooming with
wire brush etc. complete as per specifications and directions of Engineer-in-charge.
106 16.75 (The panel shuttering work shall be paid for separately). cum 1657.28 6736.74 11164664.47 0.00
(Note:- Cement content considered in this item is @ 330 kg/cum. Excess/less cement
used as per design mix is payable/ recoverable separately).
Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne
capacity after excavating earth to an average of 22.5 cm depth, dressing to camber
107 16.1 and consolidating with road roller including making good the undulations etc. and re- sqm. 4736.00 121.90 577318.40
rolling the sub grade and disposal of surplus earthwith lead upto 50 metres.
16.3 Supplying and stacking at site.
a) 16.3.2 63 mm to 45 mm size stone aggregate Cum 355.20 1194.18 424172.74
b) 16.3.3 53 mm to 22.4 mm size stone aggregate Cum 355.20 1360.68 483313.54
c) 16.3.7 Stone screening 11.2 mm nominal size (Type B) Cum 236.80 1538.56 364331.01
Laying, spreading and compacting stone aggregate of specified sizes to WBM
specifications in uniform thickness, hand picking, rolling with 3 wheeled road/
vibratory roller 8-10 tonne capacity in stages to proper grade and camber, applying
and brooming requisite type of screening / binding material to fill up interstices of
coarse aggregate, watering and compacting to the required density .
Providing, laying and making kerb channel 30 cm wide and 50 mm thick with cement
concrete 1:3:6 (1 cement: 3 coarse sand:6 graded stone aggregate 20 mm nominal
size) over 75mm bed of dry brick ballast 40 mm nominal size, well rammed and
consolidated and grouted with fine sand, including finishing the top smooth etc.
complete and as per direction of Engineer-in-charge.
Providing and laying at or near ground level factory made kerb stone of M-25 grade
cement concrete in position to the required line, level and curvature, jointed with
cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without
grooves (thickness of joints except at sharp curve shall not to more than 5mm),
110 16.69 including making drainage opening wherever required complete etc. as per direction Cum 60.11 6513.64 391534.90
of Engineer-in-charge (length of finished kerb edging shall be measured for payment).
(Precast C.C. kerb stone shall be approved by Engineerin- charge).
Providing and laying in position bitumen hot sealing compound for
expansion joints etc.
Using grade ‘A’ sealing compound. per
Providing and applying 2.5 mm thick road marking strips (retroreflective)
of specified shade/ colour using hot thermoplastic material by fully/ semi automatic
thermoplastic paint applicator machine fitted with profile shoe, glass beads dispenser,
propane tank heater and profile shoe heater, driven by experienced operator on road
112 16.62 surface including cost of material, labour, T&P, cleaning the road surface of all dirt, Sqm 700.00 472.26 330582.00
seals, oil, grease and foreign material etc. complete as per direction of Engineer-in-
charge and accordance with applicable specifications.
Total carried over to summary 14697853.67 0.00
ELECTRICAL WORK
Sub Head 1: point wiring
Wiring for light point/fanpoint/exhaust fan point/call bell point with 1.5 sq.mm.FRLS
PVC insulated, copper conductor single core cable in surface/recessed medium class
113 1.1 PVC conduit, with modular switch, modular plate, suitable GI box and earthing the
point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as
Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell
point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper
114 1.55 conductor single core cable in surface/ recessed PVC conduit, and earthing the point
with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as
Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated, copper
conductor, single core cable in surface/recessed medium class PVC conduit, with 2
115 1.11 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 Point 73.00 821.97 60003.81 0.00
sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.
ANUJ NAVNEET Digitally signed by ANUJ
CHACHA Date: 2023.01.10
BILL OF QUANTITY
Construction of Residential Accommodation for Faculty & Staff at Institute of Liver and Biliary Sciences (ILBS) at the risk and cost of previous agency
Code No. DESCRIPTION
SL.NO. UNIT QUANTITY DSR NDSR DSR NDSR
Wiring for light / power plug with 2x4 sq.mm. FRLS PVC insulated, copper conductor,
single core cable in surface/recessed medium class PVC conduit along with 1 No. 4
sq.mm FRLS PVC insulated copper conductor single core cable for loop earthing as
Wiring for circuit/ submain wiring along with earth wire with the following sizes of
117 1.14 FRLS PVC insulated copper conductor, single core cable in surface/recessed medium
class PVC conduit as required
Supplying and drawing following pair 0.5 sq mm FRLS PVC insulated annealed
118 1.18 copper conductor, unarmored telephone cable in the existing surface/recessed steel/
PVC conduit as required.
Supplying and drawing following pair 0.5 sq mm FRLS PVC insulated annealed
119 copper conductor, armored telephone cable in the existing cable tray/surface as
Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor
PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in
the existing surface/recessed steel/PVC conduit as required.
Supplying and fixing of following sizes of medium class PVC conduit alonwith the
121 1.21 accessories in surface/recess including cutting the wall and making good the same in
case of recessed conduit as required :
Supplying and fixing metal box of following sizes (nominal size) on surface or in
122 1.22 recess with suitable size of phenolilc laminated sheet cover in front including painting
etc. as required
Supplying and fixing following modular switch /socket on the existing modular plate &
123 1.24 switch box including connections but excluding modular plate etc. as reuired.
a 1.24.6 Telephone socket outlet Each 520.00 92.54 48120.80 0.00
b 1.24.7 TV antenna socket outlet Each 518.00 92.54 47935.72 0.00
Supplying and fixing two module stepped type elctronic fan regulator on the existing
124 1.25 modular plate switch box including connection but excluding modular plate etc. as Each 777.00 265.95 206643.15 0.00
Supplying and fixing following size/modules, GI box alongwith modular base & cover
125 1.27 plate for modular switches in recess etc as required. ( for telephone, TV outlets, Bell
Supplying and fixing GI box with modular plate and cover in front on surface or in
recess, including providing and fixing 3 pin 5/6 amps. modular socket outlet and 5/6
amps. Modular switch, connections etc. as required. (For light plugs).
Supplying and fixing GI box with modular plate and cover in front on surface or in
127 1.32 recess, including providing and fixing 6 pin 5/6 & 15/16 amps. modular socket outlet No. 1337.00 384.93 514651.41 0.00
and 15/16 amps. Modular switch, connections etc. as required.
Installation ,Testing, Commissioning of wall bracket /ceiling fittings of all sizes and
128 1.35 shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all Each 4822.00 76.21 367484.62 0.00
accessories including connections etc. as required.
Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden
block including connection etc. as required.
Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as
Installation, testing and commossioning of ceiling fan, including wiring the down rods
of standard length (upto 30cm) with 1.5 sq.mm. FRLS PVC insulated, copper
conductor, single core cable, incuding providing and fixing phenolic laminated sheet
cover on the fan box etc. as required.
Installation of exhaust fan in the existing opening, including making good the damage,
connection, testing, commissioning etc. as required.
Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan
clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with
its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/
M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the
corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard
ANUJ NAVNEET Digitally signed by ANUJ
CHACHA Date: 2023.01.10
BILL OF QUANTITY
Construction of Residential Accommodation for Faculty & Staff at Institute of Liver and Biliary Sciences (ILBS) at the risk and cost of previous agency
Code No. DESCRIPTION
SL.NO. UNIT QUANTITY DSR NDSR DSR NDSR
Supply, installation, testing and commissioning of Main Distribution Frame Krone type
with lockable box as required
Total:Subhead 1 13916473.12 207193.15
135 Subhead 2 : Distribution Boards and LT Panels
Supplying and fixing following way, single pole and neutral,sheet steel, MCB
distribution board, 240 V, on surface/ recess,complete with tinned copper bus bar,
neutral bus bar, earth bar, din bar, interconnections, powder painted including
earthing etc. as required. (But without MCB/RCCB/Isolator)
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel,
MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus
137 2.4 bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including
earthing etc. as required. (But without MCB/RCCB/Isolator)
Supplying and fixing 5 amps. to 32 amps. rating, 240/415 volts, 'C' curve,miniature
circuit breaker suitable for inductive load of following poles in the existing MCB DB
complete with connections, testing and commissioning etc. as required
b 2.10.3 Double pole (incomer ) Each 7.00 432.37 3026.59 0.00
Supplying and fixing single pole, blanking plate in the existing MCB DB complete etc.
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB
140 2.13 DB complete with connections, testing and commissioning etc. as required :
Supplying and fixing following rating, double pole, (single phase and neutral), 240 V,
residual current circuit breaker (RCCB), having a sensitivity current 30mA in the
existing MCB DB complete with connections, testing and commissioning etc. as
Supplying and fixing of following rating, 415 volts, 'C' curve,miniature circuit breaker
142 A/R on MR suitable for inductive load of following poles in the existing MCB DB complete with
connections, testing and commissioning etc. as required
143 A/R on MR MAIN LT PANEL
Supply, installation, testing and commissioning of M.V. cubicle type totally enclosed
floor mounted free standing type, dust, damp and vermin proof Panel complete with
incoming and outgoing switchgears and meters, M.V. danger notice plate,
interconnections with suitable capacity aluminium leads/solid aluminium strips, rods,
connection of incoming and outgoing cables with thimbles, powder coated painted
complete as per drawing and technical specifications as required.
Note: Panel shall be suitable for tube sensing based CO2 gas flooding system
INCOMERS B & D: FROM 2 Nos. 1250 kVA TRANSFORMER
Each Incomer have following
1 No. 2000A, 415V, 50kA rupturing capacity, EDO FP Air Circuit Breaker with
microprocessor release and opration counter.
1 set of indicating lamps to indicate ON, OFF and TRIP for breaker
1 Set of phase indicating lights LED type with control of 2A SP MCB
1 Set 0-2000A ammeter with Class-1 2000/5A CTs
1 No. Multifunction meter (MFM) with Class-1 2000/5A CTs and RS 485 port
1 No. CL-1 15VA 2000/5A CTs for APFCR
1 Set of over/under voltage realy with CL-5P10 15VA 2000/5A CTs contacts for trip
1 no.surge protection device Type-1/Class-B suitable for 50kA fault current
1 No.25 kVAR Fix type Capacitor bank each 63A, 415V, Ics=Icu=35kA rupturing
capacity, TPN, MCCB with ON-OFF push buttons and set of indicating lights.
INCOMERS A & E : FROM 2 Nos. 320 kVA DG SETS
Each incomer have following
1 No. 630A, 415V, 50kA rupturing capacity, EDO FP Air Circuit Breaker with
microprocessor release and opration counter.
1 set of indicating lamps to indicate ON, OFF and TRIP for breaker
1 Set of phase indicating lights LED type with control of 2A SP MCB
1 Set 0-630A ammeter with Class-1 630/5A CTs
1 No. Multifunction meter (MFM) with Class-1 630/5A CTs and RS 485 port
1 Set of over/under voltage realy with CL-5P10 15VA 630/5A CTs contacts for trip and
1 no. surge protection device Type-1/Class-B suitable for 50kA fault current
1 Set Reverse power relay with CL-5P10 15VA 630/5A CTs contacts for trip and
ANUJ NAVNEET Digitally signed by ANUJ
CHACHA Date: 2023.01.10
BILL OF QUANTITY
Construction of Residential Accommodation for Faculty & Staff at Institute of Liver and Biliary Sciences (ILBS) at the risk and cost of previous agency
Code No. DESCRIPTION
SL.NO. UNIT QUANTITY DSR NDSR DSR NDSR
2500A Phase and1250A Neutral TPN busbars of aluminium with colour coded heat
shrinkable sleeves and with SMC/DMC supports at every 600mm intervals and at
800A TPN busbars of aluminium with colour coded heat shrinkable sleeves and with
SMC/DMC supports at every 600mm intervals and at both ends
BUS COUPLERS : C
1 No. 2000A, 415V, 50kA rupturing capacity, EDO FP Air Circuit Breaker as B/C
without protective releases but with Under voltage release and ON-OFF indication
Interlocking system with electrical Interlocking between Three Incomers and one
buscoupler for operation, so that at any time no two different power supply shall be
ON & Conected together as per interlocking scheme as shown on SLD drwing No.
Programmable Logic Controller (PLC Based AMF cum load Mangement Control
Panel) to control of 2 Nos. D.G. Sets. incomers and 1 No. Tranformer incomer and 1
No. Bus Coupler with each provided the following:
1. 3-way On/Off Master/ self selector switch for Auto Load Mangement by auto
start/stop of required Gensets.
2. Complete AMF Operation
3. Protection for Low level lub oil (LLOP), High Water Temperature (HWT), Three
Times start on failure lock the D.G., U/V, O/V, U/F & O/F.
4.Suitable Nos. of Indication Lights, Push Buttons, Selector Switches, Battery Charger
CVCC type with auxiliary relays and Auxliary contactors etc. complete as required.
Note : All outgoing feeders shall have ammeter, inbuilt selector switch and set of
Class-1 CTs, ON indicating lamps & Phase spreaders.
1 No. 800A, 415V, Ics=Icu=35kA rupturing capacity, TPN MCCB with microprocessor
releases, OC/SC protection and operation counter for 400 kVAR capacitor panel
2 Nos. 630A, 415V, Ics=Icu=35kA rupturing capacity, TPN, MCCB with
microprocessor releases,extended rotary handle
2 Nos. 315A, 415V, Ics=Icu=35kA rupturing capacity, TPN, MCCB with
microprocessor releases,extended rotary handle
2 Nos. 250A, 415V, Ics=Icu=35kA rupturing capacity, TPN, MCCB with extended
4 Nos. 100A, 415V, Ics=Icu=35kA rupturing capacity, TPN, MCCB with extended
2 Nos. 63A, 415V, Ics=Icu=35kA rupturing capacity, TPN, MCCB with extended rotary
1 No. 315A, 415V, Ics=Icu=35kA rupturing capacity, TPN, MCCB with microprocessor
releases,extended rotary handle
2 Nos. 400A, 415V, Ics=Icu=35kA rupturing capacity, TPN, MCCB with
microprocessor releases,extended rotary handle
2 Nos. 160A, 415V, Ics=Icu=35kA rupturing capacity, TPN, MCCB with extended
4 Nos. 100A, 415V, Ics=Icu=35kA rupturing capacity, TPN, MCCB with extended
3 Nos. 63A, 415V, Ics=Icu=35kA rupturing capacity, TPN, MCCB with extended rotary
MAIN LT PANEL AS DESCRIBED ABOVE Each 1.00 1944102.68 0.00 1944102.68
144 A/R on MR CAPACITOR PANELS
Supply, installation, testing and commissioning of factory made Automatic Power
Factor Control Panel of following KVAR capacity having single phase MPP type, self
healing, long life low loss capacitor (loss shall not exceed 0.2W/KVAR) filled with
suitable capacitor grade oil & housed in Aluminium cane mounted on modular racks of
maximum 100 kVAR capacity and minimum 10kVAR and having current limiting
contactor circuit to supress switching inrush current to improve capacitor life. The
system shall have multistep microprocessor based power factor controller provided in
the command module having two set points for target P.F setting, automatic
adjustment of C/K, Digital PF display. The system shall be provided with each
capacitor bank Incoming isolating TP MCCB/MCB, capacitor Duty TP Contactor, &
set of ON/OFF indication Lamps and set of Push Buttons (PBs) for manual operation
& 1 no. Auto/Manual (A/M) selector switch and (10 steps) APFC relay of required
capacity for powerfactor correction panel, checking its main operating parameters
such as overloads and short circuits.
Provisions should be there to enhance the capacity of the panel by adding additional
racks of as mentioned above and to be added vertically upwards so as to avoid
occupying extra space horizontally. The other general specifications shall be as under
Note : The capacitors shall be of type LL-10 Mono long life capacitors
General Specifications :
Rated voltage : 400 to 440V A.C, 3 Phase
Rated frequency : 50 Hz
ANUJ NAVNEET Digitally signed by ANUJ
CHACHA Date: 2023.01.10
BILL OF QUANTITY
Construction of Residential Accommodation for Faculty & Staff at Institute of Liver and Biliary Sciences (ILBS) at the risk and cost of previous agency
Code No. DESCRIPTION
SL.NO. UNIT QUANTITY DSR NDSR DSR NDSR
Permissible over voltage : 1.1 Vn
Permissible over current : 1.3 ln
Temperature range : 50oC
Dielectric loss : Below 0.2 W/KVAR
Capacitors : IS 2834/1986, IEC : 831/1&2
PF Correction panel : IEC 439/ 1-2
APFCR of 10 steps
CAPACITOR PANEL
INCOMERS : 400kVAR CAPACITOR PANELS
1 No. 800A TP Isolator
1 Set of phase indicating lights LED type with control of 2A SP MCB
1 No. Auto manual selecter switch
1 No. Digital VIF meter with class-1 800/5A, CT's
Capacitor banks
10kVARx2= 20kVAR
Each 10kVAR bank to have 25A TP capacitor duty contactor , OLR and 25A TP 25kA
MCCB, on-off indicator, on-off push buttons for manual operation
15kVARx2= 30kVAR
Each 15kVAR bank to have 40A TP capacitor duty contactor , OLR and 32A TP 25kA
MCCB, on-off indicator, on-off push buttons for manual operation
25kVARx2= 50kVAR
Each 20kVAR bank to have 63A TP capacitor duty contactor , OLR and 63A TP 25kA
MCCB, on-off indicator, on-off push buttons for manual operation
50kVARx2=100kVAR
Each 50kVAR bank to have 125A TP capacitor duty contactor, OLR and 125A TP
25kA MCCB, on-off indicator, on-off push buttons for manual operation
100kVARx2=200kVAR
Each 50kVAR bank to have 250A TP capacitor duty contactor, OLR and 250A TP
25kA MCCB, on-off indicator, on-off push buttons for manual operation
Total kVAR capacity : 400kVAR
CAPACITOR PANELS AS DESCRIBED ABOVE Each 1.00 388820.54 0.00 388820.54
145 A/R on MR COMMON AREA SERVICES (C.A.S. PANEL-I)
1 No. 160A, 415V, Ics=Icu=35kA rupturing capacity, FP, MCCB with phase spreader
& extended rotary handle
1 Set of phase indicating lights LED type with control of 2A SP MCB
1 No. VIF meter (VIF) with CT's 160/5A & control of 2A SP MCB
1 No. kilo watt hour meter (kWHr) with control of 2A SP MCB
200A TPN busbars of aluminium with colour coded heat shrinkable sleeves and with
SMC/DMC supports at every 600mm intervals and at both ends
6 Nos. 100A, 415V, Ics=Icu=25kA rupturing capacity, TPN, MCCB with phase
spreader & extended rotary handle
COMMON AREA SERVICES (C.A.S PANEL-I) AS DESCRIBED ABOVE Each 1.00 73875.90 0.00 73875.90
146 A/R on MR MDB CA TYPICAL FOR HIGH RISE TOWER (Type-IV, V VI)
1 No. 100A, 415V, Ics=Icu=25kA rupturing capacity, FP, MCCB with phase spreader
& extended rotary handle
1 Set of phase indicating lights LED type with control of 2A SP MCB
1 No. VIF meter (VIF) with CT's 100/5A & control of 2A SP MCB
1 No. kilo watt hour meter (kWHr) with control of 2A SP MCB
200A phase and neutral TPN busbars of aluminium with colour coded heat shrinkable
sleeves and with SMC/DMC supports at every 600mm intervals and at both ends
2Nos. 100A, 415V, Ics=Icu=25kA rupturing capacity, TPN, MCCB with phase
spreader & extended rotary handle
3 Nos. 20A 10kA DP MCB
2 Nos. 63A 10kA FP MCB
MDB CA FOR HIGH RISE TOWER AS DESCRIBED ABOVE Each 4.00 32660.93 0.00 130643.72
COMMON AREA LIGHTING PANEL-TOWER 1 AND TYPICAL FOR TOWER 2, 3 &
1 No. 63A, 415V, 10kA FP MCB
1 Set of phase indicating lights LED type with control of 2A SP MCB
I No. Digital Multifunction Astronomical time switch
1 No. 63A FP power contactor with ON-OFF push buttons including indicating LED
Lamps (R & G) for manual over riding of the timer and a set of contacts for remote ON-
200A phase and neutral TPN busbars of aluminium with colour coded heat shrinkable
sleeves and with SMC/DMC supports at every 600mm intervals and at both ends
3 Nos. 40 A 10kA FP MCB
TOWER COMMON AREA LIGHTING PANEL AS DESCRIBED ABOVE Each 4.00 11664.62 0.00 46658.48
148 A/R on MR LIFT PANEL -TOWER 1 AND TYPICAL FOR TOWER 2, 3 & 4
1 No. 160 A FP manual change-over switch for two supplies- one from rising main
and other from MDB-CA Panel for lift Panels of high rise tower
1 No. 100A, 415V, Ics=Icu=25kA rupturing capacity, FP, MCCB with phase spreader
& extended rotary handle
ANUJ NAVNEET Digitally signed by ANUJ
CHACHA Date: 2023.01.10
BILL OF QUANTITY
Construction of Residential Accommodation for Faculty & Staff at Institute of Liver and Biliary Sciences (ILBS) at the risk and cost of previous agency
Code No. DESCRIPTION
SL.NO. UNIT QUANTITY DSR NDSR DSR NDSR
1 Set of phase indicating lights LED type with control of 2A SP MCB
1 No. VIF meter (VIF) with CT's 100/5A & control of 2A SP MCB
200A phase and neutral TPN busbars of aluminium with colour coded heat shrinkable
sleeves and with SMC/DMC supports at every 600mm intervals and at both ends
3 Nos. 63A, 415V, Ics=Icu=25kA rupturing capacity, TPN, MCCB with phase spreader
& extended rotary handle
2 Nos. 32A 10kA DP MCB
LIFT PANEL FOR TOWERS A,B AS DESCRIBED ABOVE Each 4.00 42770.26 0.00 171081.04
149 A/R on MR BASEMENT LIGHTING PANEL
1 No. 100A, 415V, Ics=Icu=25kA rupturing capacity, FP, MCCB with phase spreader
& extended rotary handle
1 Set of phase indicating lights LED type with control of 2A SP MCB
1 No. VIF meter (VIF) with CT's 100/5A & control of 2A SP MCB
1 No. kilo watt hour meter (kWHr) with control of 2A SP MCB
200A phase and neutral TPN busbars of aluminium with colour coded heat shrinkable
sleeves and with SMC/DMC supports at every 600mm intervals and at both ends
4 Nos. 32 A 10kA DP MCB
3 Nos. 32 A 10kA FP MCB
6 Nos. 40 A 10kA FP MCB
BASEMENT LIGHTING PANEL AS DESCRIBED ABOVE Each 1.00 37326.77 0.00 37326.77
150 A/R on MR METER BOARDS
i) The energy meters shall be dual register type, 3 phase, 4 wire 415V, 50Hz with built
in CTs suitable for prepaid metering & with current limiting facility
ii) The meters shall be compatible with centrally controlled billing system with RS-485
iii) Meter boards shall be suitable for mounting directly on the rising main.
151 A/R on MR METER BOARDS TYPE -A
1 No. 100A, 415V, Ics=Icu=25kA rupturing capacity, FP, MCCB with phase spreader
& extended rotary handle
1 Set of phase indicating lights LED type with control of 2A SP MCB
200A Phase and Neutral TPN busbars of aluminium with colour coded heat shrinkable
sleeves and with SMC/DMC supports at every 600mm intervals and at both ends
Meter compartments
3 Nos. Meter Compartments of suitable size with three phase 4 wire dual direct type
The vendor shall submit details before fabrication
152 A/R on MR METER BOARDS TYPE B
1 No. 63A, 415V, Ics=Icu=25kA rupturing capacity, FP, MCCB with phase spreader &
extended rotary handle
1 Set of phase indicating lights LED type with control of 2A SP MCB
200A Phase and Neutral TPN busbars of aluminium with colour coded heat shrinkable
sleeves and with SMC/DMC supports at every 600mm intervals and at both ends
Meter compartments
2 Nos. Meter Compartments of suitable size with three phase 4 wire dual direct type
The vendor shall submit details before fabrication
153 A/R on MR METER BOARDS TYPE C
1 No. 100A, 415V, Ics=Icu=25kA rupturing capacity, FP, MCCB with phase spreader
& extended rotary handle
1 Set of phase indicating lights LED type with control of 2A SP MCB
200A Phase and Neutral TPN busbars of aluminium with colour coded heat shrinkable
sleeves and with SMC/DMC supports at every 600mm intervals and at both ends
Meter compartments
2 Nos. Meter Compartments of suitable size with three phase 4 wire dual direct type
The vendor shall submit details before fabrication
154 A/R on MR Feeder Pillars
Supply, installation, testing and commissioning of following type of feeder pillars
suitable for 415V, 3 Phase, 4 wire, 50Hz supply system having degree of protection
IP-55 as per IS-2147 made out of 2mm thick CRCA sheet steel, powder coated, dust,
damp and vermin proof, partially compartmentalized , rear opening for cable
terminations & front opening for switchgears, heavy duty moulded terminal blocks for
incoming/outgoing and wiring with copper conductor 1100V grade flexible cable,
locking arrangements, earth bus, PCC foundation etc. complete as required with
following mountings : -
ANUJ NAVNEET Digitally signed by ANUJ
CHACHA Date: 2023.01.10
BILL OF QUANTITY
Construction of Residential Accommodation for Faculty & Staff at Institute of Liver and Biliary Sciences (ILBS) at the risk and cost of previous agency
Code No. DESCRIPTION
SL.NO. UNIT QUANTITY DSR NDSR DSR NDSR
155 A/R on MR INCOMER (For External Lighting)
1 No. 63A, 415V, Ics=Icu=25KA rupturing capacity,FP, MCCB
A set of phase indicating lights with control of 2A SP MCB.
I No. Digital Multifunction Astronomical time switch
1 No. 63A FP power contactor with ON-OFF push buttons including indicating LED
Lamps (R & G) for manual over riding of the timer and a set of contacts for remote ON-
One set of 200A TPN Aluminium busbars with colored PVC sleeves and SMC/DMC
busbar supports at both ends and maximum 600mm apart
Programmable electronic timer for auto switching of the external lighting switching ON
- OFF of the contractor as per the preset astranomical time settings depending upon
the seasonal requirements
40A 10KA DP MCB -3 Nos.
156 A/R on MR CLUB PANEL
1 No. 100A, 415V, Ics=Icu=35kA rupturing capacity, FP, MCCB with phase spreader
& extended rotary handle
1 Set of phase indicating lights LED type with control of 2A SP MCB
1 No. VIF meter (VIF) with CT's 100/5A & control of 2A SP MCB
1 No. kilo watt hour meter (kWHr) with control of 2A SP MCB
200A phase and neutral TPN busbars of aluminium with colour coded heat shrinkable
sleeves and with SMC/DMC supports at every 600mm intervals and at both ends
2 Nos. 63A, 415V, Ics=Icu=25kA rupturing capacity, TPN, MCCB with phase spreader
& extended rotary handle
2 Nos. 32A 10kA DP MCB
5 Nos. 40A 10kA FP MCB
CLUB PANEL AS DESCRIBED ABOVE Each 2.00 38882.05 0.00 77764.10
157 A/R on MR MULTI PURPOSE HALL PANEL
1 No. 63A, 415V, Ics=Icu=35kA rupturing capacity, FP, MCCB with phase spreader &
extended rotary handle
1 Set of phase indicating lights LED type with control of 2A SP MCB
1 No. VIF meter (VIF) with CT's 63/5A & control of 2A SP MCB
1 No. kilo watt hour meter (kWHr) with control of 2A SP MCB
200A phase and neutral TPN busbars of aluminium with colour coded heat shrinkable
sleeves and with SMC/DMC supports at every 600mm intervals and at both ends
1 No. 63A, 415V, Ics=Icu=25kA rupturing capacity, TPN, MCCB with phase spreader
& extended rotary handle
2 Nos. 32A 10kA DP MCB
3 Nos. 40A 10kA FP MCB
MULTI PURPOSE HALL PANEL AS DESCRIBED ABOVE Each 1.00 20996.31 0.00 20996.31
Total: Subhead 2 1191681.20 3876571.51
Subhead 3: Earthing
Earthing with G.I. earth pipe 4.5 meter long, 40mm dia including accessories, and
158 5.2 providing masonry enclosure with cover plate having locking arrangement and Each 18.00 4127.72 74298.96 0.00
watering pipe etc. with charcoal/coke and salt as required.
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories,
and providing masonry enclosure with cover plate having locking arrangement and
watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including
accessories, and providing masonry enclosure with cover plate having locking
arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as
required. (for lift)
Providing and fixing 50 mm x 6 mm GI strip on surface or in recess for connections
161 A/R on MR etc. as required. HT panel, LT Panels, transformers and DG Sets body earthing. M 910.00 272.17 0.00 247674.70
Providing and fixing 40 mm x 6 mm Cu strip on surface or in recess for connections
etc. as required. For Trafo and DG set neutrals earthing.
Providing and fixing 32 mm x 6 mm GI strip with heat shrinking sleeves & SMC/DMC
163 A/R on MR insulators on surface for cable tray and connections for rising mains etc. as required. M 400.00 221.63 0.00 88652.00
Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip
earth electrode, including connection/terminating with nut, bolt, spring, washer etc. as
required.(Jointing shall be done by overlapping and with 2 sets of brass nut bolt &
spring washer spaced at 50mm)
Supplying and laying 25 mm X 5 mm G.I. strip at 0.50 meter below ground as strip
earth electrode including connection/ terminating with G.I. with nut, bolt, spring,
washer etc as required. ( Jointing shall be done by overlapping and with 2 sets of nut
bolt & spring washer spaced at 50mm )
ANUJ NAVNEET Digitally signed by ANUJ
CHACHA Date: 2023.01.10
BILL OF QUANTITY
Construction of Residential Accommodation for Faculty & Staff at Institute of Liver and Biliary Sciences (ILBS) at the risk and cost of previous agency
Code No. DESCRIPTION
SL.NO. UNIT QUANTITY DSR NDSR DSR NDSR
Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth
166 5.1 electrode including connection with brass nut, bolt, spring, washer excavation and re- Each 80.00 951.83 76146.40 0.00
filling etc. as required.
Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth
167 5.11 electrode including connection with brass nut, bolt, spring, washer excavation and re- M 50.00 375.60 18780.00 0.00
filling etc. as required.
Providing and fixing 25 mm x 5 mm Copper strip on surface or in recess for
connection etc. as required.
Providing and fixing 25 mm x 5 mm G.I. strip on surface or in recess for connection
etc. as required.
Total: Subhead 3 1799824.42 926557.30
Subhead 4: Cable, Cable Tray and Miscellaneous Items
Supplying and installing Following size of perforated pre-painted M.S. cable trays
with perforation not more than 17.5% in convenient sections, joined with connectors,
suspended from the ceiling with M.S. suspenders including bolts & nuts, painting
suspenders etc as required.
a 4.1.2 150mm widthx50mm depthx1.6mm thickness M 300.00 412.93 123879.00 0.00
b 4.1.4 300mm widthx50mm depthx1.6mm thickness M 350.00 482.92 169022.00 0.00
c 4.1.6 450 mm width X 50 mm depth X 2.0 mm thickness M 100.00 544.35 54435.00 0.00
d 4.1.14 600 mm width X 75 mm depth X 2.0 mm thickness M 50.00 777.64 38882.00 0.00
e 4.1.16 900 mm width X 75 mm depth X 2.0 mm thickness M 150.00 920.73 138109.50 0.00
Supplying and installing Following size of perforated pre-painted M.S. cable trays
bends with perforation not more than 17.5% joined with connectors, suspended from
171 4.2 the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as
required. Note: As per Site Requirement
a 4.2.2 150mm widthx50mm depthx1.6mm thickness Each 5.00 736.43 3682.15 0.00
b 4.2.4 300mm widthx50mm depthx1.6mm thickness Each 5.00 1042.04 5210.20 0.00
c 4.2.6 450 mm width X 50 mm depth X 2.0 mm thickness Each 2.00 1624.49 3248.98 0.00
d 4.2.14 600 mm width X 75 mm depth X 2.0 mm thickness Each 2.00 2200.72 4401.44 0.00
e 4.2.16 900 mm width X 75 mm depth X 2.0 mm thickness Each 2.00 3053.80 6107.60 0.00
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power
172 7.5 cable of 1.1 KV grade of following size in the existing RCC/HUME/Metal pipe as
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power
173 7.6 cable of 1.1 KV grade of following size in the existing masonry open duct as required.
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power
cable of 1.1 KV grade of following size on cable tray as required.
a 7.8.1 Upto 35 sq. mm (clamped with 1 mm thick saddle) M 1375.00 25.66 35282.50 0.00
Above 35 sq.mm. and upto 95 sq.mm (clamped with 25x3 mm MS flat clamp)
Above 95 sq. mm and upto 185 sq. mm (clamped with
25/40x3mm MS flat clamp)
Above 185 sq. mm and upto 400 sq. mm (clamped with
40x3mm MS flat clamp)
Supplying and making indoor end termination with brass compression gland and
175 9.1 aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE
aluminium conductor cable of 1.1 KV grade as required.
Supplying following size of PVC insulated and PVC sheathed / XLPE
aluminium/Copper armoured conductor cable of 1.1 KV grade as required.
ANUJ NAVNEET Digitally signed by ANUJ
CHACHA Date: 2023.01.10
BILL OF QUANTITY
Construction of Residential Accommodation for Faculty & Staff at Institute of Liver and Biliary Sciences (ILBS) at the risk and cost of previous agency
Code No. DESCRIPTION
SL.NO. UNIT QUANTITY DSR NDSR DSR NDSR
Supplying and laying of following size DWC HDPE pipe ISI marked along with all
accessories like socket, bend, couplers etc.conforming to IS 14930, Part II complete
with fitting and cutting, jointing etc.direct in ground (75 cm below ground level)
including excavation and refilling the trench but excluding sand cushioning
and protective covering etc., complete as required.
Constructing masonry Chamber 45x45x45 cm inside, in brick work in cement mortar
1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm top
diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and
RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm
178 A/R on MR nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5
fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with
cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating
coat of neat cement complete as per standard design :
Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar
1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm top
diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and
RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm
179 18.33 nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5
fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with
cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating
coat of neat cement complete as per standard design :
18.33.1 With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 No. 6.00 7223.04 43338.24 0.00
Constructing masonry Chamber 90x90x100 cm inside, in brick work in cement mortar
1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm top
diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and
RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm
180 18.34 nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5
fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with
cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating
coat of neat cement complete as per standard design :
18.34.1 With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 No. 3.00 12546.58 37639.74 0.00
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV
181 8.1 grade of following size direct in ground including excavation, sand cushioning,
protective covering and refilling the trench etc as required.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV
182 8.3 grade of following size in the existing RCC/ HUME/ METAL pipe as required.
supplying and making indoor cable end termination with heat shrinkable jointing kit
183 10.4 complete with all accessories including lugs suitable for following size of 3 core, XLPE
aluminium conductor cable of 11 KV grade as required.
Supplying of following sizes of 11 kV grade aluminium conductor XLPE armoured
cable conforming to IS : 7098 (part-2)
Total: Subhead 4 1237231.84 1908288.05
Subhead 5: Internal Light fixtures and Fans
Supply of prewired LED light fixtures complete with lamp, ballast, driver, transformer
185 A/R on MR and all other accessories etc. complete factory wired with copper conductor but as
a)1x20 W LED tubelight Polycarbonate co-extrusion tube for LED light housing with
engg.plastic end caps Surface Mounted
Make/Cat Ref. : Bajaj / BCLSB 20W Each 1742.00 583.23 0.00 1015986.66
b)Decorative Wall light -Embrace White LED
c)Mirror Light (Bathroom Wall light) 7.5W Jojoba Silver, LED
d)1x5 W LED tubelight Polycarbonate co-extrusion tube for LED light housing with
engg.plastic end caps Surface Mounted
Make/Cat Ref. : Bajaj / BCLSB 5W Each 366.00 466.58 0.00 170768.28
e)10W Bulk Head
Make/ Type : Bajaj/BIBWP 10W LED Each 12.00 933.17 0.00 11198.04
f)1x6 W LED Surface Mounted Downlighter die-cast aluminum frame
Make/ Type : Bajaj/BGSLO Sleek Surface 6W WH RD Each 1434.00 1088.70 0.00 1561195.80
g)1x6 W LED Recessed Downlighter die-cast aluminum frame
Make/ Type : Bajaj/BPSLR Radiance 6W WW RD Each 250.00 777.64 0.00 194410.00
Supply of following duty and sizes of Exhaust Fans complete with motor, capacitor,
terminal block, shuttered louvers etc. complete as required.
230mm sweep 1350 r.p.m with Guard Each 553.00 933.17 0.00 516043.01
ANUJ NAVNEET Digitally signed by ANUJ
CHACHA Date: 2023.01.10
BILL OF QUANTITY
Construction of Residential Accommodation for Faculty & Staff at Institute of Liver and Biliary Sciences (ILBS) at the risk and cost of previous agency
Code No. DESCRIPTION
SL.NO. UNIT QUANTITY DSR NDSR DSR NDSR
Supply of following sizes of ceiling fans complete with fan motor, capacitor of required
rating, terminal block, standard down rod, wiring of down rod, fixing hooks with nuts &
bolts, rubber bush, shrouding caps etc. complete as required.
a)1200 mm dia sweep
Make/Type: Luminous Pulse 50 5 Star
Supplying, installing, testing and commissioning of LED based Aviation Obstruction
188 A/R on MR Light of an approved make with photo cell. (Cost of wiring to be paid seperately). Each 8.00 4665.85 0.00 37326.80
Total: Subhead 5 0.00 6196716.32
Subhead 6: Rising Mains
Supplying, installing on wall, testing and commissioning of following capacity Air
Insulated Compact Type Rising Mains for use on 3 phase 4 wire 415 volts, 50Hz A.C.
supply with enclosure having IP-54 rating after fixing the tap off boxes and all
accessories, made of 1.6mm thick steel sheet duly powder coated in convenient
sections complete with 4 Nos aluminium bus bars having current density of 130 A/ sq
cm at nominal current rating, necessary joints & expansion joints, fire barrier at each
floor, provision of tapping at every metre, continuous earthing with 2 Nos aluminium
strip of suitable size (one on each side) including, G.I. clamping brackets, angle iron
bracket, steel fasteners, connecting to earthing system etc. as required.
Supplying, installation, testing & commisioning of following capacity Plug In/ tap off
box on the existing Air Insulated Compact Type bus trunking/ rising mains for use on 3
190 3.12 phase 4wire 415 volts, 50Hz A.C. supply made with 1.6mm thick sheet steel
enclosure (IP54) duly powder coated with provision of MCCB/ACB (but without
MCCB/ACB) complete etc. as required
Supplying, installation, testing & commisioning of following capacity End Feed Unit for
the existing Air Insulated Compact Type bus trunking/ rising mains for use on 3 phase
4 wire 415volts, 50Hz A.C. supply made with 1.6mm thick steel sheet enclosure
191 3.11 (IP54) duly powder coated with provision of MCCB/ACB (but without MCCB/ACB)
complete with necessary joints including clamping brackets, angle iron bracket, steel
fasteners, connecting to earthing system etc. as required
Providing and fixing following rating and breaking capacity and pole MCCB with
thermomagnetic release and terminal spreaders in existing cubicle panel board
including drilling holes in cubicle panel, making connections, etc. as required.
Total: Subhead 24 1531418.16 0.00
Subhead 7: Fire Alarm System
Supplying & laying of 2x1.5 sqmm fire survival armoured cable, 600/1000V rated with
annealed copper conductor having glass mica fire barrier tape covered by an
193 17.5.1 extruded layer of Cross Linkable Ethylene Propylene Rubber (EPR) insulation and M 1045.00 255.07 266548.15 0.00
LSZH inner bedding, steel wire armouring & LSZH outer sheath complete as required.
Supplying, installation, testing & commissioning of manual call boxes of MS
194 17.1.3 construction in surface/recess with stainless steel chain & hammer assembly Each 54.00 359.27 19400.58 0.00
complete with glass and push button etc. as required.
Supplying, installation, testing & commissioning fire alarm sounder with facility to
make announcement, mounted in M.S. box (16 SWG) with hinged cover plate &
suitable for operation with amplifier i/c line matching transformer etc. complete as
Supplying, installation, testing & commissioning of smoke detector with builtin LED
196 17.1.2 and mounting base complete with all connections etc. as required. Each 57.00 887.29 50575.53 0.00
Supplying, installation, testing & commissioning response indicator on surface/recess
197 17.1.5 MS box having two LEDs metallic cover complete with all connections etc. as Each 53.00 143.09 7583.77 0.00
Supplying, installation, testing & commissioning talk back slave station in
surface/recess suitable for operation on simplex mode complete with P.T.T. knob &
speaker/microphone enclosed in a M.S.(16 SWG)/ ABS box with break glass in front
etc. complete as required.
ANUJ NAVNEET Digitally signed by ANUJ
CHACHA Date: 2023.01.10
BILL OF QUANTITY
Construction of Residential Accommodation for Faculty & Staff at Institute of Liver and Biliary Sciences (ILBS) at the risk and cost of previous agency
Code No. DESCRIPTION
SL.NO. UNIT QUANTITY DSR NDSR DSR NDSR
Supplying, installation, testing & commissioning of main
control and indicating panel made out of 16 SWG MS sheet to accommodate the
following items duly powder coated in approved colour with louvers for ventilation,
locking arrangement, audio and visual indication for fire alarm and public address
system, monitoring system including connections, interconnections etc complete as
10 Zone panel for fire alarm system
250 Watt amplifier racks suitable for operation on 230V
AC/24V DC supply conforming to IEC-268-3 complete with all accessories as required
- 2 Nos.(one to act as standby) Talk back master station with LED PTT (press to talk)
push button for operation on 230V AC/24 V DC supply conforming to IEC-268 for
simplex mode of operation/communication suitable for 20 Nos.talk back unit -1 set.
Annoucement control desk suitable for selection of differentzones selectively and ON
ALL CALL switch with visual indication etc. complete as required -1 set.
Amplifier change over switch for inter changing amplifier -1 No.
Monitor panel for loudspeaker complete with output selector, ON/OFF switch, fuse,
visual indications etc.
complete as required- 1 No.
Gooseneck microphone with stand and ON/OFF switch- 1 No.
Main ON/OFF switch, fuse indication lamps, DC and AC
voltmeters & ammeters, terminal blocks etc. complete as
required -1 set.
Battery charger trickle cum boost to take complete load of fire alarm & PA system
complete with all accessories
including providing & fixing of 2 nos.12 volt, 60 AH each
sealed maintenance free batteries -1 set.
Supplying, installation, testing & commissioning of central graphical fire alarm
200 17.2.2 management system to centrally monitor and operate the fire alarm system complete Each 1.00 155643.31 155643.31 0.00
Supplying, installation, testing & commissioning of addressable fire control module
complete as required.
Supply, installation, testing and commissioning of Addressable Zoning Monitor
Supply, installation, testing and commissioning of Addressable Monitor Modules for
203 A/R interfacing conventional Tower Fire alarm panel, Sprinkler flow switches with central Each 9.00 2488.45 0.00 22396.05
addressable Fire Alarm panel.
Supplying, installation, testing & commissioning of repeater panel wih 320 character/
204 17.2.3 Touch screen LCD display with inbuilt reset, acknowledge and silence switches Each 1.00 84430.05 84430.05 0.00
complete as required.
Supplying and fixing of following sizes of steel conduit along with accessories in
205 1.2 surface/recess including painting in case of surface conduit, or cutting the wall and
making good the same in case of recessed conduit as required.
Supplying, laying and connecting of following size 1.1 kV grade copper conductor
control cable (conforming to IS:1554 Part I) on wall or on existing cable tray/ in
existing pipe/trench with clamping, dressing or drawn in existing ducts all as
2X 1.5 sq.mm.unarmoured cable M 2612.50 69.99 0.00 182848.88
Total: Subhead 7 1225439.88 217687.17
Subhead 8: Lightning Protection System
Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long,
207 6.2 G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate Each 24.00 348.38 8361.12 0.00
including holes etc. complete as required.
Jointing copper / G.I. tape (with another copper/ G I tape, base of the finial or any
208 6.4 other metallic object) by riveting / nut bolting/ sweating and soldering etc as required. Each 120.00 72.32 8678.40 0.00
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for
lightning conductor complete as required. (For horizontal run)
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for
lightning conductor complete as required. (For vertical run)
Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm
211 6.12 long, with 4 nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as Each 24.00 79.32 1903.68 0.00
Providing and laying G.I. tape 32 mm X 6 mm from earth electrode directly in ground
Total: Subhead 8 280728.10 0.00
Subhead 9: HT Panel
213 A/R on MR H.T. PANEL NEAR METER ROOM
Supply, installation, testing and commissioning of 1 No. Panel 11 KV switchboard
fitted with VACCUM CIRCUIT BREAKERS with accessories as below and as per
detailed specifications.
INCOMER CUM OUTGOING END TERMINATION
ANUJ NAVNEET Digitally signed by ANUJ
CHACHA Date: 2023.01.10
BILL OF QUANTITY
Construction of Residential Accommodation for Faculty & Staff at Institute of Liver and Biliary Sciences (ILBS) at the risk and cost of previous agency
Code No. DESCRIPTION
SL.NO. UNIT QUANTITY DSR NDSR DSR NDSR
1 No. fully drawout VCB CB TP 630A and 18.4 KA breaking capacity OF 350 MVA
with closing and tripping circuit suitable for 24V DC and motorised spring charged
complete with auxiliary contacts ON/OFF indicator, spring charged/dischage indicator,
operation counter, operating handle, fully interlocked, for service, test and isolated
1 Set of dual core current transformers of ratios 300/150/5A with metering core of
class 1-0 and burden of 15 VA and protection core 5 P 1 0, burden 15 VA.
1 Set of PTs 11KV /1.734/110V/1.734 100VA burden with set of HRC fuses on H.T.
1 Set of IDMT relay for over current and earth fault with high set element
1 Set of Ammeter with Selector switch
1 Set of Voltmeter with Selector switch
1 Set indicating lamps for ON-OFF and FAULT
1 Set of indicating lamps for Trip healthy, Trip failure circuit with audible alarm.
Circuit breaker control switch.
1 Sets of panel space heaters with control switch, thermostat and fuses.
Earth bar for all panels and sliding earth contact for movable truck portions of
Testing terminal block for panels.
Panel interior illuminating lamp with door switch for all panels.
Designation labels on front and rear.
A builtin power pack unit containing AC to DC convertor with battery charger and
battery of capacity 7AH suitable for the DC load of the single breaker VCB panel
board with DC Voltmeter, Ammeter, charge selector switch, indicating lamps and
control fuses etc. ae required.
214 A/R on MR H.T. PANEL NEAR ESS
Supply of 3 Panel 11 KV switchboard with 1 incoming panel and 2 outgoing Panels
fitted with VACCUM CIRCUIT BREAKERS with accessories as below and as per
detailed specifications.
INCOMER VCB PANEL
1 No. fully drawout VCB Panel TP 630A and 18.4 kA breaking capacity of 350 MVA
with closing and tripping circuit suitable for 24V DC power and motorised spring
charged complete with auxiliary contacts ON/OFF indicator, spring charged /dischage
indicator, three position isolaotr/ earthing switch, busbar, earthbar operation counter,
operating handle, integral spring charging handle, fully interlocked, for service, test
and isolated positions with making capacity.
1 Set of dual core cast resin current transformers of ratios 11 kV, 300/150/5A with
metering core of class 1-0 and burden of 15 VA and protection core 5 P 1 0, burden
1 Set of withdrawable cast resin PTs 11KV /1.734/110V/1.734, 100VA burden of class-
1 with set of HRC fuses on H.T. and L.T. side.
METERING COMPARTMENT
Numerical relay with LCD display- IDMT relay for 2 Nos.Over Current and 1 No.Earth
Fault with high set element
Inbuilt master trip relay (86) and trip circuit supervision function
1 No. Multifunction meter with RS-485 port
1 set of Phase indicating lamps LED type with control MCB
1 Set indicating lamps for breaker ON-OFF and Trip (RGA)
Spring Charged lamp (Blue)
DC Supply healthy indicating lamp
DC failure relay with buzzer and indication with accept push button
1 Set of indicating lamps for Trip circuit healthy, Trip circuit failure with audible alarm.
Anti pumping Realy
Local remote selector switch
Circuit breaker control switch. (T-N-C)
Emergency stop push button (Red)
ANUJ NAVNEET Digitally signed by ANUJ
CHACHA Date: 2023.01.10
BILL OF QUANTITY
Construction of Residential Accommodation for Faculty & Staff at Institute of Liver and Biliary Sciences (ILBS) at the risk and cost of previous agency
Code No. DESCRIPTION
SL.NO. UNIT QUANTITY DSR NDSR DSR NDSR
1 Set of panel space heaters with control switch, thermostat and fuses.
Earth bar for all panels and sliding earth contact for movable truck portions of
Panel interior illuminating lamp with door switch for all panels.
Racking in/out, Manual closing/tripping of the circuit breaker with compartment door
Continuous rated closing/tripping coils
Testing terminal block for panels.
Auxiliary Switch with 6 NO + 6NC contacts mounted on the drawout portion of
Position/cell switch with 3 NO + 1 NC contacts, one each for TEST and SERVICE
Auxiliary switch, with 4 NO+4NC contacts, mounted on the stationary portion of the
operated mechanically by a sliding lever from the breaker in service position.
2 NOS. OUTGOING VCB PANEL
Each Breakers consisting as below
1 No. fully drawout VCB Panel TP 630A and 18.4 kA breaking capacity of 350 MVA
with closing and tripping circuit suitable for 24V DC power and motorised spring
charged complete with auxiliary contacts ON/OFF indicator, spring charged /dischage
indicator, three position isolaotr/ earthing switch, busbar, earthbar operation counter,
operating handle, integral spring charging handle, fully interlocked, for service, test
and isolated positions with making capacity.
1 Set of dual core cast resin current transformers of ratios 11 kV, 150/75/5A with
metering core of class 1-0 and burden of 15 VA and protection core 5 P 1 0, burden
METERING COMPARTMENT
Numerical relay with LCD display- IDMT relay for 2 Nos.Over Current and 1 No.Earth
Fault with high set element
Inbuilt master trip relay (86) and trip circuit supervision function
1 No. Multifunction meter with RS-485 port
1 set of Phase indicating lamps LED type with control MCB
1 Set indicating lamps for breaker ON-OFF and Trip (RGA)
Spring Charged lamp (Blue)
DC Supply healthy indicating lamp
DC failure relay with buzzer and indication with accept push button
1 Set of indicating lamps for Trip circuit healthy, Trip circuit failure with audible alarm.
Anti pumping Realy
Local remote selector switch
Circuit breaker control switch. (T-N-C)
Emergency stop push button (Red)
1 Set of panel space heaters with control switch, thermostat and fuses.
Earth bar for all panels and sliding earth contact for movable truck portions of
Panel interior illuminating lamp with door switch for all panels.
Racking in/out, Manual closing/tripping of the circuit breaker with compartment door
Continuous rated closing/tripping coils
Testing terminal block for panels.
6 Nos. auxiliary relay for Oil teperature indicator(OTI), Winding temperature indicator
(WTI), Bucholz alarm & trip.
Annunciator with electronic hooter
Auxiliary Switch with 6 NO + 6NC contacts mounted on the drawout portion of
ANUJ NAVNEET Digitally signed by ANUJ
CHACHA Date: 2023.01.10
BILL OF QUANTITY
Construction of Residential Accommodation for Faculty & Staff at Institute of Liver and Biliary Sciences (ILBS) at the risk and cost of previous agency
Code No. DESCRIPTION
SL.NO. UNIT QUANTITY DSR NDSR DSR NDSR
Position/cell switch with 3 NO + 1 NC contacts, one each for TEST and SERVICE
Auxiliary switch, with 4 NO+4NC contacts, mounted on the stationary portion of the
operated mechanically by a sliding lever from the breaker in service position.
Designation labels on front and rear.
Supplying and fixing of tripping battery 24V supply with a Self Contained floor
mounting cabinet complete with required number of lead acid maintenance free
storage batteries of capacity of 125 AH each suitable for the DC load of the 3 panel Each 1.00 738759.02 0.00 738759.02
board and with a float cum boost charger with DC Voltmeter, Ammeter, charge
selector switch, indicating lamps and control fuses.
Total: Subhead 9 0.00 1010933.40
Subhead 10: Distribution Transformers
215 A/R on MR 1250kVA DRY TYPE INDOOR TRANSFORMER
Supply, installation, testing and commissioning of 11KV/.433KV, 1250 KVA dry type
transformer conforming to IS: 11171, suitable for indoor installation, including
mounting channels, making cable connections on H.T. and cable box L.T. side
suitable for 6 nos. 3.5C 400sq. mm aluminium conductor armoured cables, complete
with all accessories as per detailed specification.
a) 1250KVA dry type transformer
b) Off circuit tap changer with +5% to -5% in steps of 2.5% on HT side. Each 1.00 1166461.61 0.00 1166461.61
Total: Subhead 10 0.00 1166461.61
Subhead 11: D.G. Sets
Supply of Sound Attenuated Weather Proof type of D.G. Set of required rating
complete with diesel engine and alternator of suitable rating, micro processor based
216 A/R on MR control panel for metering, monitoring, protection and electronic governing of the
engine and all other accessories as per detailed specifications and as specically
mentioned below :
Sound Attenuated Weather Proof Canopy : Shall be engineered to meet all the CPCB-
Engine : Radiator Cooled, Fuel Efficient and meeting emission norms
Alternator : Efficient, Brushless, self-excited, with electronic AVR, rated for 0.8 pf 415
Volt, 3 Phase 4 Wire, 50 Hz supply; coupled to engine
Control Panel : Microprocessor based compatible having DG Set performance
parameetrs display panel, diagnostics and engine and alternator protection features,
remote monitoring & data logging, compatibility panels,etc.
Providing the HSD and other comsumables for the successful comissioning of the DG
Accessories : Base frame with maintenance free vibration control system, fuel storage
tank in the base, required nos. of batteries with battery charger and stand, and other
accessories as per detailed specifications and as requred for the successful operation
Installation, testing and commisioning of DG Sets of following capacities including
217 A/R on MR hoisting, placing on plinths, supply of HSD and other consumables required for
successful commissioning, all complete.
Note : All civil and structural steel work for plinth construction will be done by a third
party as per the detailed design and drawings provided by the DG Set Vendor.
a) 320 kVA DG Set to be installed as required Each 2.00 46658.46 0.00 93316.92
Supply, jointing by welding, installation and commissioning of DG Exhaust Pipe
System fabricated out of heavy quality (Class C) M.S. pipes conforming to IS:1239
(Part I) - 1990 for pipes upto 150 mm dia. and IS:3589-1991 for pipes above 150mm
dia. including fittings i.e. tees, bends, elbows, unions, reducers, draining arrangement,
flange joints, rubber insertion, nuts & bolts etc. as required including fixing of exhaust
system on existing walls, slabs, steel structure etc. with flat iron strap work, including
painting with two coats of anti-corrosive paint. The exhaust system shall be insulated
with 75 mm thick ROCK wool insulation of 150 Kg per cubic meter density on around
of Exhaust pipe and silencer, firmly kept in place with chicken wire mesh wrapping
and followed by cladding with aluminium sheet of 24 SWG, complete as required and
as per specification.
The Sizes of the exhaust piping are indicative only and the DG set supplier should
furnish the Calculations for exhaust piping sizes for approval by the
architect/consultant/Client
The System should meet the performance of the engine without exceeding the back
pressure limit prescribed by the engine manufacturer.
In case the selected size as per calculation of back pressure is not the same as
specified below than the size and the rate of the size so selected shall also be
ANUJ NAVNEET Digitally signed by ANUJ
CHACHA Date: 2023.01.10
BILL OF QUANTITY
Construction of Residential Accommodation for Faculty & Staff at Institute of Liver and Biliary Sciences (ILBS) at the risk and cost of previous agency
Code No. DESCRIPTION
SL.NO. UNIT QUANTITY DSR NDSR DSR NDSR
a) Supply and fixing of 125 mm dia MS Black Pipe 4.85mm thick complete with Bends
a A/R on MR & Flanges. With Rockwool 75mm Thick wire mesh and 24 gauge aluminium cladding M 10.00 777.64 0.00 7776.40
b) Supply and fixing of 150 mm dia MS Black Pipe 4.85mm thick complete with Bends
b A/R on MR & Flanges. With Rockwool 75mm Thick wire mesh and 24 gauge aluminium cladding M 150.00 1010.93 0.00 151639.50
c A/R on MR c) Supply of MS Support for exhaust piping kg 500.00 77.76 0.00 38880.00
d A/R on MR d) Supply of Flexible SS Belows (as per site condition) Each 4.00 9331.69 0.00 37326.76
Total: Subhead 11 0.00 4994786.00
Subhead 12: Lifts
Supply, Installation, Testing and Commissioning of MRL Lifts including 1 year's
Guarantee & Free Maintenance
Design, manufacturing, testing at works, supply and delivery, receiving, unloading,
storing, inspection, handling, assembling, installing in correct assigned position,
effecting proper connections, testing and commissioning of following capacity MRL
passenger-lifts, having speed of 1.5 MPS 12 stops and 12 openings and total travel of
37.0 Meters approx. with VVVF drive, full collective Simplex/duplex control on 415V,
50 cycles, 3 phase power complete in accordance with specifications and drawings as
required with Car, Car Door & Hoistway Door in stainless steel hairline finish, inclusive
of builtin ARD and as per specification. Note :- Refer Sections 1.1 & 1.2 of Technical
Specification for genral requirements of MRL Lifts.
(i) 13 Passenger (1020Kg) For Highrise Towers (Refer Sections 1.1) No. 4.00 1710810.36 0.00 6843241.44
(ii) 8 Passenger (544Kg) For Highrise Towers (Refer Sections 1.2) No. 4.00 1555282.14 0.00 6221128.56
Total: Subhead 12 0.00 13064370.00
Subhead 13: Street Light Poles & Light Fixtures
Supply and errection of flange mounted hot dip galvanized conical pole of specified
length made from 3mm thick MS sheet, complete with window with sliding flush cover
at a height of 0.5 M from the base for cable termination block etc and galvanized
base plate of size 25mm x 225mm x 16mm / as required. The pole top shall be
complete with 1000 mm long arm bracket at specified height with a tilt of 0 degree
with tightening bolts as required. The following may be housed in the window
provided for cable termination including their supply and fixing:: 6mm thick laminated
mounting sheet of suitable size inside the window by providing and welding three No
GI strips; 4 mm thick of suitable length and having suitable size tapped holes - 10 nos.
220 A/R on MR as required. : 1 No. : A set of 20 Amp brass neutral link, 2 way copper bus bar on
existing laminated sheet : 1 Set.: 4 way, 32 Amp heavy duty terminal block suitable
for 10 sq. mm conductor- 2nos. and shorting links (4nos.) on DIN channel of suitable
length - on the existing laminated sheet. : Earth stud welded at suitable height with
two nos. washer, spring washer & nuts. : 2 Nos.: 4 Nos. (20mm dia x 470mm long)
G.I foundation bolts with nuts washer, 2 nos. templates (4 mm thick, 220mm x 22
0mm size), making of 4 Nos. x 24 mm dia holes with PCD of 205mm for 6 M Poles .
The tem-plate (Top) shall have a 120 mm dia hole at center for cable entry
b) 6M long Conical pole- BCP-6030- ( Top Dia: 75mm, Bottom dia: 140 mm, pole
thickness:3mm) with 0.5M single arm bracket along
c)3) 6M long Conical pole- BCP-6030- ( Top Dia: 75mm, Bottom dia: 140 mm, pole
thickness:3mm) with 0.5M double arm bracket
d) 4M long Conical pole- BCP-4030- ( Top Dia: 75mm, Bottom dia: 118 mm, pole
thickness:3mm) with 0.2M single arm bracket
Supply of following type of prewired street light luminaires complete with lamps,
221 A/R on MR ballast, transformers, drivers as required of following makes and models (or approved
a) Make : Bajaj
Model No. : ARAIN-BCGT W4 LED WW
Housing: Die-cast aluminum graphite grey powder coated
Mounting Height: 4M
Color Temp: Warm White : 3000k - White Each 25.00 23329.23 0.00 583230.75
b) Make : Bajaj
Model No. : EDGE-BRTFG 45W LED WW
Housing: Pressure Die-cast aluminum with toughend glass
Mounting Height: 6M
Color Temp: Warm White : 3000k - White Each 35.00 11664.62 0.00 408261.70
Supply, installation, wiring, testing and commissioing of prewired Ground burial light
fixtures with housing and lamp, ballast, transformers, drivers complete with all
accessories etc. including making PCC foundation embedding in ground, providing
nuts and bolts, 3C1.5 sq.mm. copper flexible cord from the loop-in-loop-out box up to
the light fixture etc. complete in all respect.
Model No. : SPYK2-BGSBL 9W LED WW
Housing: Graphite grey powder coated integral aluminium
Color Temp: Warm White : 3000k - White Each 20.00 11664.62 0.00 233292.40
ANUJ NAVNEET Digitally signed by ANUJ
CHACHA Date: 2023.01.10
BILL OF QUANTITY
Construction of Residential Accommodation for Faculty & Staff at Institute of Liver and Biliary Sciences (ILBS) at the risk and cost of previous agency
Code No. DESCRIPTION
SL.NO. UNIT QUANTITY DSR NDSR DSR NDSR
Supply, installation, wiring, testing and commissioing of prewired Bollard light fixtures
with lamp,ballast, transformers, drivers complete with all accessories etc. including
223 A/R on MR making PCC foundation, providing nuts and bolts, 3C 1.5 sq.mm. copper flexible cord
from the loop-in-loop-out box up to the light fixture etc. complete in all respect.
Model No. : TETRIS-BGOS605 9W LED
Housing: Graphite grey powder coated square extruded aluminium
Color Temp: Warm White : 3000k - White Each 10.00 11664.62 0.00 116646.20
Supply, installation, wiring, testing and commissioing of wall recessed LED light
224 A/R on MR fixture with lamp, ballast, transformers, drivers including cutting the required size
opening in wall and making good the same
Model No. : VERTICO-BLWUP 9W LED WW
Housing: Graphite grey powder coated integral aluminium
Color Temp: Warm White : 3000k - White Each 20.00 7776.41 0.00 155528.20
Supply and installation of loop-in loop-out box made of polycarbonate having IP-68
rating, approximate size 100X100X65MM with screwless three pole three way
terminal with grommets for outgoing cord etc. complete as required.
Total: Subhead 13 0.00 2311538.25
Sub Head 1 : SANITARY FIXTURES AND TOILET REQUISITES
17.7A Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole
226 basin mixer of approved quality and make, including painting of fittings and brackets,
cutting and making good the walls wherever required:-
(a) White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass
single hole basin mixer
17.10 Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS 13983 with
227 C.I. brackets and stainless steel plug 40 mm including painting of fittings and
brackets, cutting and making good the walls wherever required :
17.10.1 Kitchen sink with drain board
17.78 Providing and fixing white vitreous china extended wall mounting water closet of size
780x370x690 mm of approved shape including providing & fixing white vitreous china
228 cistern with dual flush fitting, of flushing capacity 3 litre/6 litre (adjustable to 4 litre/8 Each 452.00 10772.23 4869047.96 0.00
litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete.
17.80 Providing and fixing white vitreous china battery based infrared sensor operated urinal
of approx. size 610 x 390 x 370 mm having pre & post flushing with water (250 ml &
229 500 ml consumption), having water inlet from back side, including fixing to wall with Each 10.00 5376.53 53765.30 0.00
suitable brackets all as per manufacturers specification and direction of Engineer-in-
AR on MR Providing and fixing of brass single flow shower with revolving ball joint and 190 mm
long branch light body shower arm with wall flange. (or equal approved).
a) Model : Jaquar Continental
Colour/Finish : Chrome Each 447.00 2955.04 0.00 1320902.88
AR on MR Providing and fixing of wall mounted bath cum shower mixer fitting with diverter lever
and bend for overhead shower connection including making connections with water
231 supply, cutting and making good the walls wherever required. (or equal approved).
17.22A Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and
as per the direction of Engineer-in-charge.
AR on MR Providing and fixing of 15 mm dia brass angle valve (inlet fitting ball valve type)
233 having strainer screen complete with wall flange of following make and model:(or
equal approved)
Make : ARCO, Spain
Colour/Finish : Chrome Each 3090.00 427.70 0.00 1321593.00
AR on MR Providing and fixing of 15 mm dia, 450 mm long flexible connection pipe having
234 EPDM rubber internal core and stainless steel braided outer sheath complete with C.P Each 2638.00 233.29 0.00 615419.02
brass end nuts, of approved make.
AR on MR Providing and fixing C.P brass ablution faucet (health faucet) comprising hand held
shower with operating lever, 1 m long flexible tube and wall hook all complete.
Model : Continental
ANUJ NAVNEET Digitally signed by ANUJ
CHACHA Date: 2023.01.10
BILL OF QUANTITY
Construction of Residential Accommodation for Faculty & Staff at Institute of Liver and Biliary Sciences (ILBS) at the risk and cost of previous agency
Code No. DESCRIPTION
SL.NO. UNIT QUANTITY DSR NDSR DSR NDSR
Cat. No. : 573
Colour/Finish : Chrome Each 452.00 1671.93 0.00 755712.36
236 AR on DSR Providing and fixing CP Brass 32mm size waste fitting for wash basin complete. Each 451.00 87.10 0.00 39282.10
AR on MR Providing and fixing of 15 mm dia. C.P. brass wall-mounted Kitchen sink mixer with
swivel spout and wall flange of following make.(or equal approved).
Model : Continental
Cat. No. : 319KN
Colour/Finish : Chrome Each 116.00 2760.63 0.00 320233.08
AR on MR Providing and fixing electric water storage heater (geyser) of following capacities
including making inlet / outlet connections, of approved makes.
17.28 Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste
fittings complete.
17.28.2 Flexible pipe
18.51 Providing and fixing C.P. brass long body bib cock of approved quality conforming to
IS standards and weighing not less than 690 gms.
Total : Sub Head No. 1 Rs. 8925734.76 9346312.62
Sub Head 2 : SOIL, WASTE & VENT AND RAIN WATER PIPEWORK
241 17.35 Providing and fixing soil, waste and vent pipes :
17.35.1.2 Centrifugally cast (spun) iron socket & spigot (S&S) pipe as per IS: 3989. Metre 7282.00 849.34 6184893.88 0.00
17.35.2.2 Centrifugally cast (spun) iron socket & spigot (S&S) pipe as per IS: 3989. Metre 2134.00 771.46 1646295.64 0.00
17.37 Providing and fixing M.S. holder-bat clamps of approved design to Sand Cast
iron/cast iron (spun) pipe embedded in and including cement concrete blocks
242 10x10x10cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20
mm nominal size) including cost of cutting holes and making good the walls etc. :
17.38 Providing and fixing bend of required degree with access door, insertion rubber
washer 3 mm thick, bolts and nuts complete
17.38.1.2 Sand cast iron S&S as per IS - 3989 Each 4.00 359.00 1436.00 0.00
244 17.39 Providing and fixing plain bend of required degree.
17.39.2.2 Sand cast iron S&S as per IS : 3989 Each 72.00 225.32 16223.04 0.00
17.43 Providing and fixing single equal plain junction of required degree with access door,
insertion rubber washer 3 mm thick, bolts and nuts complete.
246 17.44 Providing and fixing single equal plain junction of required degree :
17.44.1.2 Sand cast iron S&S as per IS - 3989 Each 2.00 519.23 1038.46 0.00
247 17.49 Providing and fixing double equal plain invert branch of required degree:
17.49.1.2 Sand cast iron S&S as per IS - 3989 Each 1.00 579.58 579.58 0.00
248 17.50 Providing and fixing single equal plain invert branch of required degree:
17.50.1.2 Sand cast iron S&S as per IS - 3989 Each 30.00 470.32 14109.60 0.00
249 17.56 Providing and fixing terminal guard
17.56.1.2 Sand cast iron S&S as per IS - 3989 Each 98.00 302.81 29675.38 0.00
17.56.2.2 Sand cast iron S&S as per IS - 3989 Each 44.00 240.95 10601.80 0.00
17.58 Providing lead caulked joints to sand cast iron / centrifugally cast (spun) iron pipes
and fittings of diameter.
ANUJ NAVNEET Digitally signed by ANUJ
CHACHA Date: 2023.01.10
BILL OF QUANTITY
Construction of Residential Accommodation for Faculty & Staff at Institute of Liver and Biliary Sciences (ILBS) at the risk and cost of previous agency
Code No. DESCRIPTION
SL.NO. UNIT QUANTITY DSR NDSR DSR NDSR
17.59 Providing and fixing M.S. stays and clamps for sand cast iron / centrifugally cast
(spun) iron pipes of diameter.
17.65 Painting sand cast iron/ centrifugally cast (spun) iron soil, waste vent pipes and fittings
with two coats of synthetic enamel paint of any colour such as chocolate grey, or buff
etc. over a coat of primer (of approved quality) for new work :
18.12 Providing and fixing G.I. pipes complete with G.I. fittings including trenching and
For Waste line in toilets and Kitchen
18.38 Painting G.I. pipes and fittings with synthetic enamel white paint with two coats over a
254 ready mixed priming coat, both of approved quality for new work :.
For Waste line in toilets and Kitchen
a 18.38.4 32 mm dia. nominal bore Metre 649.00 22.09 14336.41 0.00
17.61 Cutting chases in brick masonry walls for following diameter sand cast iron/
centrifugally cast (spun) iron pipes and making good the same with cement concrete
255 1:3:6 ( 1 cement : 3 coarse sand :6 graded stone aggregate 12.5 mm nominal size),
including necessary plaster and pointing in cement mortar 1:4 (1 cement : 4 coarse
For Waste line in toilets and Kitchen
12.41 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming
to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving
10 mm gap for thermal expansion.(i) Single socketed pipes.
12.42 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming
to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving
10 mm gap for thermal expansion.(i) Single socketed pipes.
12.42.2 Single pushfit Coupler :
c 12.42.3 Single tee with door
d 12.42.4 Single tee without door
12.43 Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised
- PVC rain water pipes by means of 50x50x50mm hard wood plugs, screwed with
258 M.S. screws of required length including cutting brick work and fixing in cement
mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.
259 12.44 diameter and weighing not less than 440 grams. Each 677.00 36.74 24872.98 0.00
AR on DSR Providing and fixing of floor traps formed of Cast Iron 'P' traps complete, including
260 cost of cutting and making good the walls and floors wherever required.
a) 100 mm inlet and 100 mm outlet Each 565.00 933.17 0.00 527241.05
ANUJ NAVNEET Digitally signed by ANUJ
CHACHA Date: 2023.01.10
BILL OF QUANTITY
Construction of Residential Accommodation for Faculty & Staff at Institute of Liver and Biliary Sciences (ILBS) at the risk and cost of previous agency
Code No. DESCRIPTION
SL.NO. UNIT QUANTITY DSR NDSR DSR NDSR
AR on MR Providing and fixing floor trap Extension Piece made out of 100 mm dia M.S. pipe
(heavy grade C-Class) of required length (upto 450 mm) with 32 mm to 50 mm dia
threaded maleable iron sockets ( maximum 4 nos.) welded as side inlets, neatly
finished, inside and outside painted with 2 coats of redoxide primer & 2 coats of
synthetic enamel paint, including the cost of jointing with floor trap with dripseal joint.
AR on MR Providing and fixing floor drain points formed out of 100 X 50 mm dia reducing elbow
262 with suitable extension piece including cost of cutting and making good the walls and Each 467.00 1244.23 0.00 581055.41
floors wherever required.
AR on MR Providing and fixing 125 mm dia round chrome plated bronze grating with frame,
screw down type embedded in floor, all complete.
AR on MR Providing and fixing screwed down type nickel bronze alloy cast floor cleanout with
2 opening arrangements for soil / waste pipe and other necessary fittings inlcuding
jointing, all complete as per standard detail.
AR on MR Providing and fixing cleanout with opening arrangements by providing 300 mm long
G.I. nipple welded to 6 mm thick flange sealed with 6 mm thick blank flange including
nuts and bolts, rubber insertions etc. all complete as per standard detail.
265 17.48 Providing and fixing single unequal plain junction of required degree :
17.48.1.2 Sand cast iron S&S as per IS - 3989 Each 55.00 621.18 34164.90 0.00
266 17.52 Providing and fixing single unequal plain invert branch of required degree :
267 AR on MR Providing and fixing soil, waste and vent pipes :
Centrifugally cast (spun) iron socket & spigot (S&S) pipe as per IS: 3989. Metre 902.00 1088.70 0.00 982007.40
268 AR on MR Providing and fixing single unequal plain invert branch of required degree :
Sand cast iron S&S as per IS - 3989 Each 200.00 933.17 0.00 186634.00
AR on MR Providing lead caulked joints to sand cast iron / centrifugally cast (spun) iron pipes
and fittings of diameter.
AR on MR Painting sand cast iron/ centrifugally cast (spun) iron soil, waste vent pipes and fittings
with two coats of synthetic enamel paint of any colour such as chocolate grey, or buff
etc. over a coat of primer (of approved quality) for new work :
150 mm diameter pipe Metre 902.00 77.76 0.00 70139.52
Total : Sub Head No. 2 Rs. 18379288.59 4319800.88
Sub Head 3 : WATER SUPPLY
18.7 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal
stability for hot & cold water supply, including all CPVC plain & brass threaded fittings,
271 including fixing the pipe with lamps at 1.00 m spacing. This includes jointing of pipes
& fittings with one step CPVC solvent cement and testing of joints complete as per
direction of Engineer in Charge.
Internal work – Exposed on wall
a 18.7.1 15 mm nominal outer dia .Pipes. Metre 352.00 187.84 66119.68 0.00
b 18.7.2 20 mm nominal outer dia .Pipes. Metre 985.00 238.70 235119.50 0.00
c 18.7.3 25 mm nominal outer dia .Pipes. Metre 1606.00 287.11 461098.66 0.00
d 18.7.4 32 mm nominal outer dia .Pipes. Metre 1744.00 373.70 651732.80 0.00
e 18.7.5 40 mm nominal outer dia .Pipes. Metre 1711.00 504.38 862994.18 0.00
f 18.7.6 50 mm nominal outer dia .Pipes. Metre 1535.00 702.60 1078491.00 0.00
18.8 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal
stability for hot & cold water supply including all CPVC plain & brass threaded fittings
i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes &
fittings with one step CPVC solvent cement and the cost of cutting chases and making
good the same including testing of joints complete as per direction of Engineer in
Concealed work including cutting chases and making good the walls etc.
a 18.8.1 15 mm nominal outer dia .Pipes. Metre 15499.00 318.56 4937361.44 0.00
b 18.8.2 20 mm nominal outer dia .Pipes. Metre 6028.00 371.83 2241391.24 0.00
c 18.8.3 25 mm nominal outer dia .Pipes. Metre 28.00 437.00 12236.00 0.00
d 18.8.4 32 mm nominal outer dia .Pipes. Metre 11.00 528.13 5809.43 0.00
18.9 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal
stability for hot & cold water supply including all CPVC plain & brass threaded fittings
This includes jointing of pipes & fittings with one step CPVC solvent cement ,trenching
,refilling & testing of joints complete as per direction of Engineer in Charge.
a 18.9.1 15 mm nominal outer dia .Pipes. Metre 22.00 157.74 3470.28 0.00
b 18.9.2 20 mm nominal outer dia .Pipes. Metre 39.00 197.29 7694.31 0.00
c 18.9.3 25 mm nominal outer dia .Pipes. Metre 39.00 254.02 9906.78 0.00
d 18.9.4 32 mm nominal outer dia .Pipes. Metre 11.00 321.71 3538.81 0.00
ANUJ NAVNEET Digitally signed by ANUJ
CHACHA Date: 2023.01.10
BILL OF QUANTITY
Construction of Residential Accommodation for Faculty & Staff at Institute of Liver and Biliary Sciences (ILBS) at the risk and cost of previous agency
Code No. DESCRIPTION
SL.NO. UNIT QUANTITY DSR NDSR DSR NDSR
e 18.9.5 40 mm nominal outer dia .Pipes. Metre 11.00 417.40 4591.40 0.00
f 18.9.6 50 mm nominal outer dia .Pipes. Metre 407.00 615.62 250557.34 0.00
18.13 Making connection of G.I. distribution branch with G.I. main of following sizes by
274 providing and fixing tee,including cutting and threading the pipe etc. complete
18.48 Providing and placing on terrace (at all floor levels) polyethylene water storage tank
ISI : 12701 marked with cover and suitable locking arrangement and making
necessary holes for inlet, outlet and overflow pipes but without fittings and the base
support for tank
AR on MR Providing and fixing of nickel plated brass/ nonferrous alloy fullyway ball valve (
276 minimum working pressure of 20 bar ) with operating handle of approved make.
AR on MR Providing and fixing Cast Iron butterfly valve as per IS: 13095 of Class PN 10, having
epoxy coated disc, carbon steel shaft, EPDM / nitrile rubber field replacible body lining
and of approved make. including a set of MS flanges, required nos. of nut & bolts all
AR on MR Providing and fixing insulation to hot water piping with closed cell polyolefine foam
preformed pipe sleeves of specified wall thickness using propriety adhesive and self
adhesive tapes, all as per the manufacturer's specifications.
a) 15 mm dia - 9 mm thickness Metre 5203.00 89.43 0.00 465304.29
b) 20 mm dia - 9 mm thickness Metre 2992.00 94.87 0.00 283851.04
c) 25 mm dia - 13 mm thickness Metre 259.00 136.09 0.00 35247.31
d) 32 mm dia - 13 mm thickness Metre 237.00 157.86 0.00 37412.82
e) 40 mm dia - 13 mm thickness Metre 259.00 181.19 0.00 46928.21
f) 50 mm dia - 20 mm thickness Metre 33.00 332.05 0.00 10957.65
AR on MR Extra for providing and wrapping with 5 mile glass cloth on hot water lines insulation
279 and applying of coat of hardner paint of approved shade, all complete in a
workmanship like manner ( on exposed pipework)
a) 15 mm dia pipe plus insulation Metre 66.00 63.77 0.00 4208.82
b) 20 mm dia pipe plus insulation Metre 105.00 76.99 0.00 8083.95
c) 25 mm dia pipe plus insulation Metre 259.00 90.21 0.00 23364.39
d) 32 mm dia pipe plus insulation Metre 226.00 109.65 0.00 24780.90
e) 40 mm dia pipe plus insulation Metre 242.00 131.42 0.00 31803.64
f) 50 mm dia pipe plus insulation Metre 33.00 160.19 0.00 5286.27
AR on MR Supplying, Installing, Testing and Commissioning of Solar Water Heating System as
per following details
i) Method of Circulation - Closed Circuit Thermo-siphon
ii) Method of Water Heating - Indirect - either through jacketed hot water storage tank
or through coil type heat exchanger fixed within hot water storage tank.
iii) Solar Collector Panel:
Absorptivity Factor - 0.95
Emittance Factor - 0.1
Type - Flat bed Collector Panel
Size - 2M X 1M (Nominal Size)
MOC - Copper Water grid, black polyester coated full sheet absorber, toughened
glass, weather proof aluminium casing, mineral wool insulation
Other specification
Standard - Shall be inline with IS: 12933 part-1.
iv) Hot Water Storage Tank:
Working pressure - 2.5 kg/cm2 (Minimum)
MOC - Stainless Steel - SS 316 grade OR SS316 lined OR ceramic lined complete
with 50 mm thick PUF insulation, duly protected; and inlet-outlet nozzles. The tank
shall be fitted with a sacrificial anode.
v) Interconnecting Pipework : All interconnecting pipework in Medium Class (Class-
B) G.I. Pipe with Heavy Class malleable cast iron fitings suitable for threaded joints
and valves. G.I. Pipe work conforming to IS:1239 (Part I)-1990 and G.I. fittings
conforming to IS: 1879
Battery Limits: Between Solar panels and hot water collection tank.
vi) Accessories: Pressure gauges, Safety valve etc.
vii) Mounting structure: Mounted on Galvanized Steel frame
(i) 400 litres per day with 4 no. collector plates No. 9.00 171081.04 0.00 1539729.36
AR on MR Supplying pressure reducing valve, suitable for water application and having following
Body — Forged Brass / Bronze
Seat — Stainless Steel
ANUJ NAVNEET Digitally signed by ANUJ
CHACHA Date: 2023.01.10
BILL OF QUANTITY
Construction of Residential Accommodation for Faculty & Staff at Institute of Liver and Biliary Sciences (ILBS) at the risk and cost of previous agency
Code No. DESCRIPTION
SL.NO. UNIT QUANTITY DSR NDSR DSR NDSR
Ends — Female Screwed Ends
Maximum Working Pressure — Upto 16 bar
Adjustable Pressure Range — 1.0 bar (Minimum) - 6.0 bar
Provision for installing Pressure Gauge : 1/4 inch port
AR on MR Providing and fixing in position the medium class (Class B) G.I. pipes (IS:1239) with
all fittings, specials & clamps effecting proper connections, cutting and making good
the walls and floors etc. (Internal Work). Note: Pipe work in shafts, ceiling voids and
282 terrace shall be supported/ fixed on MS structural supports with U-clamps complete
with nuts and washers.Cost for MS structural work for supports shall be included in
the rates all complete. ( At terrace level and riser mains)
AR on DSR Painting G.I. pipes and fittings with synthetic enamel white paint with two coats over a
283 ready mixed priming coat, both of approved quality for new
2.10 Excavating trenches of required width for pipes, cables, etc including excavation for
sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including
getting out the excavated soil, and then returning the soil as required, in layers not
exceeding 20 cm in depth, including consolidating each deposited layer by ramming,
watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50
2.10.1 All kinds of soil
2.10.1.1 Pipes, cables etc, not exceeding 80 mm dia. Metre 446.00 173.41 77340.86 0.00
Total : Sub Head No. 3 Rs. 11069894.47 4785041.13
Sub Head 4 : SEWERAGE AND STORM WATER DRAINAGE
19.1 Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of
285 cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of
joints etc. complete :
19.2 Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded
286 stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as
per standard design :
4.1 Providing and laying in position cement concrete of specified grade excluding the cost
of centering and shuttering - All work up to plinth level :
Bed concrete for RCC NP2 Pipe
4.1.5 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) Cum. 171.00 4867.33 832313.43 0.00
19.6 Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars
288 jointed with stiff mixture of cement mortar in the proportion of 1 : 2 (1 cement : 2 fine
sand) including testing of joints etc. complete.
19.7 Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand
) with R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone
aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse
sand : 8 graded stone aggregate 40mm nominal size), inside plastering 12mm thick
289 with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat
cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4
graded stone aggregate 20mm nominal size) finished with a floating coat of neat
cement complete as per standard design :
19.7.1 Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty)
455x610 mm internal dimensions, total weight of cover and frame to be not less than
38 kg (weight of cover 23 kg and weight of frame 15 kg) :
19.7.1.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 Each 42.00 8480.21 356168.82 0.00
290 19.8 Extra for depth for manholes.
19.8.1 Size 90x80 cm
19.8.1.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 Metre 6.00 5834.64 35007.84 0.00
ANUJ NAVNEET Digitally signed by ANUJ
CHACHA Date: 2023.01.10
BILL OF QUANTITY
Construction of Residential Accommodation for Faculty & Staff at Institute of Liver and Biliary Sciences (ILBS) at the risk and cost of previous agency
Code No. DESCRIPTION
SL.NO. UNIT QUANTITY DSR NDSR DSR NDSR
19.9 Constructing brick masonry circular type manhole 0.91 m internal dia at bottom and
0.56m dia at top in cement mortar 1:4 (1 cement :4 coarse sand), in side cement
plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a
floating coat of neat cement, foundation concrete 1:3:6 mix (1 cement : 3 coarse sand
291 : 6 graded stone aggregate 40 mm nominal size), and making necessary channel in
cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm
nominal size) finished with a floating coat of neat cement, all complete as per
standard design :
19.9.1 0.91 m deep with S.F.R.C. cover and frame (heavy duty, HD-20 grade designation)
560 mm internal diameter conforming to I.S. 12592, total weight of cover and frame to
be not less than 182 kg., fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4
graded stone aggregate 20 mm nominal size) including centering, shuttering all
complete. (Excavation, foot rests and 12mm thick cement plaster at the external
surface shall be paid for separately) :
19.9.1.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 Each 32.00 8583.68 274677.76 0.00
19.10 Extra depth for circular type manhole 0.91m internal dia (at bottom) beyond 0.91 m to
19.10.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 Metre 14.00 5014.54 70203.56 0.00
19.11 Constructing brick masonry circular manhole 1.22 m internal dia at bottom and 0.56 m
dia at top in cement mortar 1:4 (1 cement :4 coarse sand) inside cement plaster 12
mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating
coat of neat cement foundation concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded
stone aggregate 40 mm nominal size) and making necessary channel in cement
concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal
size) finished with a floating coat of neat cement, all complete as per standard design
19.11.1 1.68 m deep with SFRC Cover and frame (heavy duty HD-20 grade designation) 560
mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be
not less than 182 kg. fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4
graded stone aggregate 20 mm nominal size) including centering, shuttering all
complete. (Excavation, foot rests and 12 mm thick cement plaster at the external
surface shall be paid for separately) :
19.11.1.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 Each 2.00 16513.71 33027.42 0.00
19.12 Extra depth for circular type manhole 1.22 m internal dia (at bottom) beyond 1.68 m to
19.12.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
19.16 Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated
as per IS : 10910, on 12 mm dia steel bar conforming to IS: 1786, having minimum
cross section as 23 mmx25 mm and over all minimum length 263 mm and width as
165 mm with minimum 112 mm space between protruded legs having 2 mm tread on
top surface by ribbing or chequering besides necessary and adequate anchoring
projections on tail length on 138 mm as per standard drawing and suitable to with
stand the bend test and chemical resistance test as per specifications and having
manufacture’s permanent identification mark to be visible even after fixing, including
fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3
coarse sand : 6 graded stone aggregate 20 mm nominal
size) complete as per design.
296 13.4 12 mm cement plaster of mix :
For external surface plaster of 0.91 m dia, 1.22 m dia & 1.52 m dia manhole
297 19.27 mortar 1:4 (1 cement : 4 coarse sand) including 500x450 mm pre-cast R.C.C.
19.27.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 Each 140.00 4050.81 567113.40 0.00
2.10 Excavating trenches of required width for pipes, cables, etc including excavation for
sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including
getting out the excavated soil, and then returning the soil as required, in layers not
exceeding 20 cm in depth, including consolidating each deposited layer by ramming,
watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50
2.10.1 All kinds of soil
a 2.10.1.1 Pipes, cables etc, not exceeding 80 mm dia. Metre 0.00 173.41 0.00 0.00
b 2.10.1.2 Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia Metre 2431.00 283.22 688507.82 0.00
c 2.10.1.3 Pipes, cables etc. exceeding 300 mm dia but not exceeding 600 mm Metre 11.00 442.17 4863.87 0.00
2.11 Extra for excavating trenches for pipes, cables etc. in all kinds of soil for depth
299 exceeding 1.5 m, but not exceeding 3 m. (Rate is over corresponding basic item for
depth upto 1.5 metre).
a Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia Metre 187.00 359.68 67260.16 0.00
b Pipes, cables etc. exceeding 300 mm dia but not exceeding 600 mm Metre 11.00 561.55 6177.05 0.00
19.3 Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded
300 stone aggregate 40 mm nominal size) up to haunches of S.W. pipes including bed
concrete as per standard design :
For R.C.C. NP2 PIPE
ANUJ NAVNEET Digitally signed by ANUJ
CHACHA Date: 2023.01.10
BILL OF QUANTITY
Construction of Residential Accommodation for Faculty & Staff at Institute of Liver and Biliary Sciences (ILBS) at the risk and cost of previous agency
Code No. DESCRIPTION
SL.NO. UNIT QUANTITY DSR NDSR DSR NDSR
AR on MR Providing, Laying, Jointing and Testing of HDPE Pipes and Fittings.(For surplus
effluent discharge from STP bye-pass line)
The work shall be done as per specifications and in general shall include:
a) Providing HDPE pipes (of PE 80 grade as per IS 4984-1995). The pipes shall have
a working pressure of PN 10.
b) Providing factory fabricated and moulded fittings (including flanged tail pieces, slip
on flanges, flanges with welding neck etc.) suitable for butt jointing and flange jointing
as the case may be. The fitting shall be rated PN16 upto 63 mm OD and PN10 for 75
mm OD and above.
c) Laying in position in excavated trenches. (Excavation of trenches to be paid
seperately as per relevant item)
d) Jointing by heat fusion technique.
e) Providing and laying LDPE/PVC warning tape ( in florescent colour) of size 25 mm
wide and 50 micron thick. The warning tape shall be laid 150 mm above the pipe
AR on MR Providing and fixing moulded HDPE compression type (as specified) adaptor fittings,
saddles, etc. for connecting HDPE pipework to pipework of other materials and
appurtenances including jointing, testing etc. all complete.
a) Compression Flange Adaptor
4.1 Providing and laying in position cement concrete of specified grade excluding the cost
of centering and shuttering - All work up to plinth level :
For thrust blocks
4.1.3 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cum. 0.10 5279.09 527.91 0.00
18.41 Providing and filling sand of grading zone V or coarser grade, allround the G.I. pipes
in external work :
18.31 Providing and fixing C.I. sluice valves (with cap) complete with bolts, nuts, rubber
insertions etc. (the tail pieces if required will be paid separately) :
18.31.1 100 mm diameter
19.21 Making connection of drain or sewer line with existing manhole including breaking into
and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2
coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on
both sides with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating
coat of neat cement and making necessary channels for the drain etc. complete :
a 19.21.1 For pipes 100 to 250 mm diameter each 1.00 484.86 484.86 0.00
b 19.21.3 For pipes 350 to 450 mm diameter each 2.00 805.21 1610.42 0.00
AR on MR BOREWELL CUM DUGWELL : Constructing a borewell cum dugwell ground
307 water recharge structure generally as per enclosed standard detail and having Job 6.00 388820.54 0.00 2332923.24
following construction specifications :
Volume of Dugwell : 38 Cum.
Peripherical brick masonry in cement mortar 1:4 ( 1 cement:4 coarse sand) with
necessary 15 mm thick cement plaster 1:3 neat finish.
Foundation concrete for walls 1:5:10 (300mm thick)
Providing and laying in position 300 mm thick 5-10 mm size gravel
Providing and laying in position 300 mm thick 5-15 cm size gravel
Providing and laying in position 300 mm thick dry stone aggregate bed (40 to 65 mm
200 mm thick R.C.C ( 1:2:4) slab to cover the well at top including necessary centring,
shuttring and reinforcement with required opening/cutouts etc. supplying & fixing 600
mm X 600 mm S.F.R.C Manhole cover / frame( total weight 208 Kg.) heavy duty type,
all complete as per drawings.
1 No. 160 mm dia PVC blind/ perforated pipe lowered vertically upto first granular
saturated sandy formation including necessary drilling / boring in ground in all kinds of
Providing and packing suitable size pea gravel all around casing pipe in the bore
Supplying & fixing P.V.C foot rests.
Making all inlets & outlets in brick masonry walls including cutting holes & making
10-12 mm thick cement plaster 1:3 mixed with water profing compound on top of
R.C.C slabs & in ceiling of slab, finished smooth.
Note: Dimensions may vary as per the site conditions.
Total : Sub Head No. 4 Rs. 4526167.74 2387250.00
Sub Head 5 : EXTERNAL WATER SUPPLY AND LANDSCAPE IRRIGATION
308 AR on MR Providing, Laying, Jointing and Testing of HDPE Pipes and Fittings.
The work shall be done as per specifications and in general shall include:
ANUJ NAVNEET Digitally signed by ANUJ
CHACHA Date: 2023.01.10
BILL OF QUANTITY
Construction of Residential Accommodation for Faculty & Staff at Institute of Liver and Biliary Sciences (ILBS) at the risk and cost of previous agency
Code No. DESCRIPTION
SL.NO. UNIT QUANTITY DSR NDSR DSR NDSR
a) Providing HDPE pipes (of PE 80 grade as per IS 4984-1995). The pipes shall have
a working pressure of PN 10.
b) Providing factory fabricated and moulded fittings (including flanged tail pieces, slip
on flanges, flanges with welding neck etc.) suitable for butt jointing and flange jointing
as the case may be. The fitting shall be rated PN16 upto 63 mm OD and PN10 for 75
mm OD and above.
c) Laying in position in excavated trenches. (Excavation of trenches to be paid
seperately as per relevant item)
d) Jointing by heat fusion technique.
e) Providing and laying LDPE/PVC warning tape ( in florescent colour) of size 25 mm
wide and 50 micron thick. The warning tape shall be laid 150 mm above the pipe
AR on MR Providing and fixing moulded HDPE compression type (as specified) adaptor fittings,
saddles, etc. for connecting HDPE pipework to pipework of other materials and
appurtenances including jointing, testing etc. all complete.
a) Compression Flange Adaptor
b) 90 degree Elbow with threaded female offtake
4.1 Providing and laying in position cement concrete of specified grade excluding the cost
of centering and shuttering - All work up to plinth level :
For thrust blocks
4.1.3 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cum. 5.00 5279.09 26395.45 0.00
18.41 Providing and filling sand of grading zone V or coarser grade, allround the G.I. pipes
in external work :
18.31 Providing and fixing C.I. sluice valves (with cap) complete with bolts, nuts, rubber
insertions etc. (the tail pieces if required will be paid separately) :
18.31.1 100 mm diameter
AR on MR Providing and fixing C.I. sluice valves with hand wheel complete with bolts, nuts,
rubber insertions etc. (as per IS:14846)
AR on MR Providing, fixing, testing and commissioning of Full Bore Ball Valves of approved
Body : Nickel plated brass
Ball : Chrome plated brass
Operating Handle : Aluminium/ Steel with protective colour coded sleeve
Pressure Rating : Minimum 20 Bar
Temerature Withstanding : 900 C Min.
AR on MR Providing, installing and commissioning 20 mm dia brass quick release coupling
valves, complete with lid, preassembled triple swing joint in PVC, GI support rod with
SS hose clamps all complete as per standard detail including making connections
with main supply line.
316 AR on MR Supply of Quick Coupling Keys complete with Swivel elbow complete Nos. 5.00 777.64 0.00 3888.20
AR on MR Providing and installing HDPE Valve Boxes with screw down type covers, of following
sizes and shape, including excavation and filling of pea gravel in 100 mm deep layer
at bottoms, all as per standared detail ( for QRCV, Ball Valves, Butterfly Valves, Flush
ANUJ NAVNEET Digitally signed by ANUJ
CHACHA Date: 2023.01.10
BILL OF QUANTITY
Construction of Residential Accommodation for Faculty & Staff at Institute of Liver and Biliary Sciences (ILBS) at the risk and cost of previous agency
Code No. DESCRIPTION
SL.NO. UNIT QUANTITY DSR NDSR DSR NDSR
18.33 Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar
1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm top
diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and
RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm
318 nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5
fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with
cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating
coat of neat cement complete as per standard design :
18.33.1 With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 each 9.00 7223.04 65007.36 0.00
2.10 Excavating trenches of required width for pipes, cables, etc including excavation for
sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including
getting out the excavated soil, and then returning the soil as required, in layers not
exceeding 20 cm in depth, including consolidating each deposited layer by ramming,
watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50
2.10.1 All kinds of soil
2.10.1.1 Pipes, cables etc, not exceeding 80 mm dia. M 1200.00 173.41 208092.00 0.00
2.10.1.2 Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia M 280.00 283.22 79301.60 0.00
19.35 Providing and laying Non Pressure NP-3 class (Medium duty) R.C.C. pipes including
collars/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1
cement : 2 fine sand) including testing of joints etc. complete
18.80 Disinfecting C.I. water mains by flushing with water containing bleaching powder @
0.5 gms per litre of water and cleaning the same with fresh water, operation to be
repeated three times including getting the sample of water from the disinfected main
tested in the municipal laboratory.
18.59 Providing and fixing C.I. double acting air valve of approved quality with bolts, nuts,
rubber insertions etc. complete (The tail pieces, tapers etc if required will be paid
Total : Sub Head No. 5 Rs. 885566.43 896667.98
MISCELLANEOUS ITEMS
10.15 Providing and fixing M.S. Tubular frames for doors, windows, ventilators and
cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints
323 mitred, welded and grinded finish, with profiles of required size, including fixing of
necessary butt hinges and screws and applying a priming coat of approved steel
10.15.1 Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10
cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm Kg 450.00 106.77 48046.50 0.00
AR on MR Providing and fixing G.I. vent pipe with antimosquito grating of the following sizes (for
under ground/over head water tanks only) :
AR on MR Providing and fixing in position following sizes pipe inserts with puddle flanges,
fabricated with heavy duty MS pipe pieces conforming to IS: 1239 and puddle flange
made of 6 mm thick MS plate welded to the pipe piece, entire piece hot dipped
galvanised, all complete as per Standard Detail, including fixing at desired position in
the form work for RCC walls / slabs before pouring of concrete.
326 AR on MR Providing, fixing, testing and commissioning of Water level controller in Overhead
The water level controller shall comprise of the following:
a) Magnetic float type level sensing unit of stainless steel or any other non corrosive
b) Motorized valve/ Solenoid valve
c) Level controller unit including power supply in a weather proof enclosure (minimum
d) Interconnecting wiring duly protected and properly clamped
e) Mounting arrangement for the components described at (a), (b) and (c)
Note: Power supply at 220 volts, 50 Hz. Would be provided by others on the nearest
Total : Sub Head No. 6 Rs. 48046.50 560290.18
Sub Head 7 : PUMPING MACHINERY AND ALLIED EQUIPMENTS
ANUJ NAVNEET Digitally signed by ANUJ
CHACHA Date: 2023.01.10
BILL OF QUANTITY
Construction of Residential Accommodation for Faculty & Staff at Institute of Liver and Biliary Sciences (ILBS) at the risk and cost of previous agency
Code No. DESCRIPTION
SL.NO. UNIT QUANTITY DSR NDSR DSR NDSR
NOTE: The Vendor has to get the technical data sheets of all the equipment and
7 HYDROPNEUMATIC SYSTEM FOR RESIDENTIAL AND CLUB BLOCK FOR
AR on MR Supply, installing, testing and commissioning of clear water Factory Fitted packaged
327 hydropneumatic pumping system for general water supply as per following details:
Type of Drive - Variable frequency drive for each pump
Discharge (each pump):10 M3/hr.
System Pressure : 7.0 kg/cm2
Pumps- 2 Nos. (1 working + 1 standby)
The packaged unit shall be complete with :
a) Pumps: Vertical inline booster pumpset with mechanical seal
Material of Construction (M.O.C):
: Impeller — Stainless Steel -AISI 304
: Shaft — Stainless Steel - AISI 304
: Pump Head — Cast Iron/ Stainless
: Base — Cast Iron
: Motor Stool — Cast Iron
Motor: 2900 RPM; 3Ph 415V 50Hz
Insulation Class - F
Efficiency - IE2 Min.
Protection - IP54 Min.
b) Pressure Tank: FRP vessel with replacable polyetheruethane (PEU) bladder
certified for drinking water. Minimum 10 Bar pressure rating — 1 No. of 200 to
250 Lts. Capacity.
c) Interconnecting Pipe work and Valves: Common suction & delivery headers
in hot dipped galvanized iron, Isolating valves on suction & delivery side, non
return valves on delivery side of pumps.
d) Common fabricated base frame, duly painted.
e) Power and control cabling between panel and pumps.
f) Accessories like presure guages, pressure transducers etc.
g) System Control Panel : The system control panel shall be factory built and
tested and shall have the following minimum features:
i) Fully protected, powder coated metallic housing.
ii) Complete switchgear, under/over voltage protection, single phase preventors
iii) VFDs for all the pumps
iv) Site programmable application optimised software
v) Integrated Modbus interface for BMS compatibility
vi) Large graphic display with as easy to use menu.
Programmable Control System shall be PLC based, duly authentiated by the
Pump Manufacturer.
The pump Panel shall be also to convese with Building Management System
Notes: 1) Switchgear and starter ratings are indicative. The Tenderer shall quote
for the actual rating required as per the pump model proposed by him.
2) Provision for BMS connectivity. The panel should have sufficient no. of
potential free contacts for connectivity with Building Management System for
monitoring purposes
HYDROPNEUMATIC SYSTEM FOR RESIDENTIAL AND CLUB BLOCK FOR
AR on MR Supply, installing, testing and commissioning of clear water Factory Fitted packaged
328 hydropneumatic pumping system for treated effluent supply for flushing as per
following details:
Type of Drive - Variable frequency drive for each pump
Discharge (each pump): 6 M3/hr.
System Pressure : 7.0 kg/cm2
Pumps- 2 Nos. (1 working + 1 standby)
The packaged unit shall be complete with :
a) Pumps: Vertical inline booster pumpset with mechanical seal
Material of Construction (M.O.C):
: Impeller — Stainless Steel -AISI 304
: Shaft — Stainless Steel - AISI 304
: Pump Head — Cast Iron/ Stainless
: Base — Cast Iron
: Motor Stool — Cast Iron
Motor: 2900 RPM; 3Ph 415V 50Hz
Insulation Class - F
Efficiency - IE2 Min.
Protection - IP54 Min.
ANUJ NAVNEET Digitally signed by ANUJ
CHACHA Date: 2023.01.10
BILL OF QUANTITY
Construction of Residential Accommodation for Faculty & Staff at Institute of Liver and Biliary Sciences (ILBS) at the risk and cost of previous agency
Code No. DESCRIPTION
SL.NO. UNIT QUANTITY DSR NDSR DSR NDSR
b) Pressure Tank: FRP vessel with replacable polyetheruethane (PEU) bladder
certified for drinking water. Minimum 10 Bar pressure rating — 1 No. of 200 to
250 Lts. Capacity.
c) Interconnecting Pipe work and Valves: Common suction & delivery headers
in hot dipped galvanized iron, Isolating valves on suction & delivery side, non
return valves on delivery side of pumps.
d) Common fabricated base frame, duly painted.
e) Power and control cabling between panel and pumps.
f) Accessories like presure guages, pressure transducers etc.
g) System Control Panel : The system control panel shall be factory built and
tested and shall have the following minimum features:
i) Fully protected, powder coated metallic housing.
ii) Complete switchgear, under/over voltage protection, single phase preventors
iii) VFDs for all the pumps
iv) Site programmable application optimised software
v) Integrated Modbus interface for BMS compatibility
vi) Large graphic display with as easy to use menu.
Programmable Control System shall be PLC based, duly authentiated by the
Pump Manufacturer.
The pump Panel shall be also to convese with Building Management System
Notes: 1) Switchgear and starter ratings are indicative. The Tenderer shall quote
for the actual rating required as per the pump model proposed by him.
2) Provision for BMS connectivity. The panel should have sufficient no. of
potential free contacts for connectivity with Building Management System for
monitoring purposes
HYDRO-PNEUMATIC SYSTEMS - FOR TWO UPPER FLOORS OF TOWERS-
AR on MR Supply, installing, testing and commissioning of clear water packaged
hydropneumatic pumping system for general water supply for two upper floors of
each tower (with a single VFD common for both pumps) as per following details:
The packaged unit shall be complete with :
a) Pumps: Horizontal monoblock / Vertical inline booster pumpset with
mechanical seal
2 nos. (1 working+1 standby)
Material of Construction (M.O.C):
: Impeller — Stainless Steel -AISI 304
: Shaft — Stainless Steel - AISI 304
: Pump Head — Cast Iron
: Base — Cast Iron
: Motor Stool — Cast Iron
Motor: 2900 RPM; 3Ph 415V 50Hz
Insulation Class - F
Efficiency - IE2 Min.
Protection - IP54 Min.
Discharge ( each pump) : 6.0 M3/hr.
Working Pressure : 2.5 kg/sq.cm.
b) Pressure Tank: FRP vessel with replacable polyetheruethane (PEU) bladder
certified for drinking water. Minimum 8 Bar pressure rating — 1 No. 200 Lts.
c) Interconnecting Pipe work and Valves : Common suction & delivery headers
in hot dipped galvanised iron, Isolating valves and non return valves on suction
& delivery side of pumps.
d) Common fabricated base frame, duly painted.
e) Power and control cabling between panel and pumps.
f) Accessories like presure guages, pressure switches etc.
g) Electric control panel mounted on the skid for automatic operation of pumps
comprising incoming switch fuse unit/MCBB, digital voltmeter & ammeter with
selector switches, over load and under voltage protection devices, single phase
preventors, MCB and DOL starter for each pump, indicating lights etc. all
Programmable Control System shall be PLC based, duly authentiated by the
Pump Manufacturer.
Notes: 1) Switchgear and starter ratings are indicative. The Tenderer shall quote
for the actual rating required as per the pump model proposed by him.
2) Provision for BMS connectivity. The panel should have sufficient no. of
potential free contacts for connectivity with Building Management System for
monitoring purposes
HYDRO-PNEUMATIC SYSTEMS - FOR TWO UPPER FLOORS OF TOWERS-
TYPE- V (To be installed at terrace level)
AR on MR Supply, installing, testing and commissioning of clear water packaged
hydropneumatic pumping system for general water supply for two upper floors of
each tower (with a single VFD common for both pumps) as per following details:
The packaged unit shall be complete with :
ANUJ NAVNEET Digitally signed by ANUJ
CHACHA Date: 2023.01.10
BILL OF QUANTITY
Construction of Residential Accommodation for Faculty & Staff at Institute of Liver and Biliary Sciences (ILBS) at the risk and cost of previous agency
Code No. DESCRIPTION
SL.NO. UNIT QUANTITY DSR NDSR DSR NDSR
a) Pumps: Horizontal monoblock / Vertical inline booster pumpset with
mechanical seal
2 nos. (1 working+1 standby)
Material of Construction (M.O.C):
: Impeller — Stainless Steel -AISI 304
: Shaft — Stainless Steel - AISI 304
: Pump Head — Cast Iron
: Base — Cast Iron
: Motor Stool — Cast Iron
Motor: 2900 RPM; 3Ph 415V 50Hz
Insulation Class - F
Efficiency - IE2 Min.
Protection - IP54 Min.
Discharge ( each pump) : 4.0 M3/hr.
Working Pressure : 2.5 kg/sq.cm.
b) Pressure Tank: FRP vessel with replacable polyetheruethane (PEU) bladder
certified for drinking water. Minimum 8 Bar pressure rating — 1 No. 200 Lts.
c) Interconnecting Pipe work and Valves : Common suction & delivery headers
in hot dipped galvanised iron, Isolating valves and non return valves on suction
& delivery side of pumps.
d) Common fabricated base frame, duly painted.
e) Power and control cabling between panel and pumps.
f) Accessories like presure guages, pressure switches etc.
g) Electric control panel mounted on the skid for automatic operation of pumps
comprising incoming switch fuse unit/MCBB, digital voltmeter & ammeter with
selector switches, over load and under voltage protection devices, single phase
preventors, MCB and DOL starter for each pump, indicating lights etc. all
Programmable Control System shall be PLC based, duly authentiated by the
Pump Manufacturer.
Notes: 1) Switchgear and starter ratings are indicative. The Tenderer shall quote
for the actual rating required as per the pump model proposed by him.
2) Provision for BMS connectivity. The panel should have sufficient no. of
potential free contacts for connectivity with Building Management System for
monitoring purposes
HYDRO-PNEUMATIC SYSTEMS - FOR TWO UPPER FLOORS OF TOWERS-
TYPE-VI (To be installed at terrace level)
AR on MR Supply, installing, testing and commissioning of clear water packaged
hydropneumatic pumping system for general water supply for two upper floors of
each tower (with a single VFD common for both pumps) as per following details:
The packaged unit shall be complete with :
a) Pumps: Horizontal monoblock / Vertical inline booster pumpset with
mechanical seal
2 nos. (1 working+1 standby)
Material of Construction (M.O.C):
: Impeller — Stainless Steel -AISI 304
: Shaft — Stainless Steel - AISI 304
: Pump Head — Cast Iron
: Base — Cast Iron
: Motor Stool — Cast Iron
Motor: 2900 RPM; 3Ph 415V 50Hz
Insulation Class - F
Efficiency - IE2 Min.
Protection - IP54 Min.
Discharge ( each pump) : 5.0 M3/hr.
Working Pressure : 2.5 kg/sq.cm.
b) Pressure Tank: FRP vessel with replacable polyetheruethane (PEU) bladder
certified for drinking water. Minimum 8 Bar pressure rating — 1 No. 200 Lts.
c) Interconnecting Pipe work and Valves : Common suction & delivery headers
in hot dipped galvanised iron, Isolating valves and non return valves on suction
& delivery side of pumps.
d) Common fabricated base frame, duly painted.
e) Power and control cabling between panel and pumps.
f) Accessories like presure guages, pressure switches etc.
g) Electric control panel mounted on the skid for automatic operation of pumps
comprising incoming switch fuse unit/MCBB, digital voltmeter & ammeter with
selector switches, over load and under voltage protection devices, single phase
preventors, MCB and DOL starter for each pump, indicating lights etc. all
Programmable Control System shall be PLC based, duly authentiated by the
Pump Manufacturer.
Notes: 1) Switchgear and starter ratings are indicative. The Tenderer shall quote
for the actual rating required as per the pump model proposed by him.
2) Provision for BMS connectivity. The panel should have sufficient no. of
potential free contacts for connectivity with Building Management System for
monitoring purposes
ANUJ NAVNEET Digitally signed by ANUJ
CHACHA Date: 2023.01.10
BILL OF QUANTITY
Construction of Residential Accommodation for Faculty & Staff at Institute of Liver and Biliary Sciences (ILBS) at the risk and cost of previous agency
Code No. DESCRIPTION
SL.NO. UNIT QUANTITY DSR NDSR DSR NDSR
SUMP DRAINAGE PUMPS
AR on MR Supply, installing, testing and commissioning drainage pumping system in the ramp
332 base sump of plant room & STP plant room S-1 & S-2 comprising of the following:
a) 2 Nos.Vertical fully floodable type submersible drainage pumps in close
coupled design single stage, suitable for handling minimum 12 mm dia solids.
Discharge of each pump : 150 LPM
Working Head : 14 M
Material of Construction (M.O.C):
Corrosion Resistant in general
: Bearings — Anti friction,
prelubricated ball bearings,
packed with grease for life.
Motor: — Dry Motor with built in over
load protection
Protection - IP68.
Efficiency - IE2 Min.
Insulation Class - F
b) Electric control panel for automatic operation of pumps as per the water level
in the sump.The pump operation shall be controlled with magnetic float type
level controller.The Panel shall comprise of incoming MCB, digital voltmeter &
ammeter, On-Off lamps, starters with circuit breakers for each pump, rotating
start sequence, both pumps to work simultaneously to meet peak flow
There shall be an audio-visual alarm, if any pump fails to start.
c) Power cabling and control cabling between magnetic float type controller
panel and pump panels including cable tray as required.
d) Each pump should be skid base mounted of 9" height to avoid mud choking.
e) Pump suspension systemwith Stainless Steel Sling wire with `U` clamp.
f) HDPE Flexible Reinforced Hose with both side matching jubilee clamp for
ease of connection and disconnection from discharge pipe. Hose shall 3000 mm
in length (Approximate). Hose size shall not be less than 50 mm dia.
AR on MR Supply, installing, testing and commissioning drainage pumping system in the ramp
base sump of Basement Parking S-4 comprising of the following:
a) 2 Nos.Vertical fully floodable type submersible drainage pumps in close
coupled design single stage, suitable for handling minimum 12 mm dia solids.
Discharge of each pump : 300 LPM
Working Head : 14 M
Material of Construction (M.O.C):
: Bearings — Anti friction,
Motor: — Dry Motor with built in over
Protection - IP68.
Efficiency - IE2 Min.
Insulation Class - F
b) Electric control panel for automatic operation of pumps as per the water level
in the sump.The pump operation shall be controlled with magnetic float type
level controller.The Panel shall comprise of incoming MCB, digital voltmeter &
ammeter, On-Off lamps, starters with circuit breakers for each pump, rotating
start sequence, both pumps to work simultaneously to meet peak flow
There shall be an audio-visual alarm, if any pump fails to start.
c) Power cabling and control cabling between magnetic float type controller
panel and pump panels including cable tray as required.
d) Each pump should be skid base mounted of 9" height to avoid mud choking.
e) Pump suspension systemwith Stainless Steel Sling wire with `U` clamp.
f) HDPE Flexible Reinforced Hose with both side matching jubilee clamp for
ease of connection and disconnection from discharge pipe. Hose shall 3000 mm
in length (Approximate). Hose size shall not be less than 50 mm dia.
AR on MR Supply, installing, testing and commissioning drainage pumping system in the sump
of basement drainage S-3 & S-5 comprising of the following:
a) 2 Nos.Vertical fully floodable type submersible drainage pumps in close
coupled design single stage, suitable for handling minimum 12 mm dia solids.
Discharge of each pump : 100 LPM
Working Head : 14 M
Material of Construction (M.O.C):
: Bearings — Anti friction,
Motor: — Dry Motor with built in over
Protection - IP68.
Efficiency - IE2 Min.
Insulation Class - F
b) Electric control panel for automatic operation of pumps as per the water level
ANUJ NAVNEET Digitally signed by ANUJ
CHACHA Date: 2023.01.10
BILL OF QUANTITY
Construction of Residential Accommodation for Faculty & Staff at Institute of Liver and Biliary Sciences (ILBS) at the risk and cost of previous agency
Code No. DESCRIPTION
SL.NO. UNIT QUANTITY DSR NDSR DSR NDSR
c) Power cabling and control cabling between magnetic float type controller
d) Each pump should be skid base mounted of 9" height to avoid mud choking.
e) Pump suspension systemwith Stainless Steel Sling wire with `U` clamp.
f) HDPE Flexible Reinforced Hose with both side matching jubilee clamp for Set 2.00 139975.39 0.00 279950.78
LANDSCAPE IRRIGATION PUMPS
AR on MR Supply, installing, testing and commissioning of packaged pumping system for
treated effluent supply (For Landscape Irrigation) as per following details:
The packaged unit shall be complete with :
a) Pump & Motor:
RPM : 2900 RPM;
Power Supply: 3Ph 415V 50Hz
Insulation: Class - F
Motor Efficiency: Min. IE2
Protection:- IP54 Min.
Material of Construction (M.O.C):
: Impeller — Stainless Steel
: Shaft — Stainless Steel
Nos.: 2 nos. (1 working + 1 standby)
Discharge (each pump) : 7 M3/Hour
b) Pressure Tank: FRP vessel with replacable polyetheruethane (PEU) bladder
certified for drinking water. Minimum 10 Bar pressure rating — 2 No. 150 Lts.
c) Electric control panel mounted on the skid for automatic operation of pumps
comprising incoming switch fuse unit/ MCBB, digital voltmeter & ammeter with
selector switches, over load and under voltage protection devices, single phase
preventors, MCB and DOL starter for each pump, indicating lights etc, dry suction
cutoff, all complete.
d) Sequential Control System for the following logic:
i) System to start manually/automatically
ii) System stops automatically if the cut out pressure is achieved
iii) At every start, the other pump shall cut in
the idea is to keep both the pumps operational but with one remaining standby at any
particular moment.
There shall be audio visual alarm in case any pump fails to starts.
e) Interconnecting Pipe work and Valves : Common suction & delivery headers
in PVC Schedule 80 pipes conforming to ASTM-D 1785 and fittings conforming
to ASTM-D 2467, Isolating valves, non return valves on suction & delivery side
of pumps, Accessories like presure guages, pressure switches etc.
f) Common fabricated base frame, duly painted.
g) Power and control cabling between panel and pumps. Set 1.00 369379.51 0.00 369379.51
Notes: 1) Switchgear and starter ratings are indicative. The Tenderer shall quote
for the actual rating required as per the pump model proposed by him.
WATER TREATMENT PLANT
AR on MR Collecting water sample(s) in a manner as perscribed by the laboratory, making
arrangement for the delivery of the sample(s) to the laboratory and getting the
336 sample(s) tested as per IS:10500 - Drinking Water Standard (complete physical, Job 3.00 7776.41 0.00 23329.23
chemical and micro-biological test) and submitting the report(s) to the Engineer-in-
AR on MR Providing, installing, testing and commissioning vertical down flow type multi grade
sand bed pressure filter capable of filtering 8 cum/hour of water at prescribed
filteration rate of 15 cum/sq.m/hr. The filter shall comprise of Composite FRP PP
lined shell, suitable for a minimum operating pressure of 5 kg/sq.cm. , complete with
pedestal, access cover, PVC underbed, 50 mm dia frontal piping, butterfly valve,
pressure guage, first charge of filter media. etc.
Details of Filter
Filter Shell MOC : Fibre glass and
polyester resin
Height : 1800 MM
AR on MR Providing, installing, testing and commissioning chlorine doser comprising 100 litres
capacity chemical grade polypropylene storage tank, electronic metering pump of 0 -
5 litres/hr. capacity against the minimum line pressure of 3 kg/cm2 , injection fitting,
solution delivery tube etc. including making electrical connection including
synchronisation for auto operation with raw water feed pump, all complete.
AR on MR Supplying, installing, testing and commissioning of Horizontal monoblock booster
pumpsets as per following details:
The pump unit shall be complete with :
a) Pumps: Horizontal monoblock booster pumpset with mechanical seal
a) Raw Water Feed Pumps
Discharge : 8 M3/Hr
ANUJ NAVNEET Digitally signed by ANUJ
CHACHA Date: 2023.01.10
BILL OF QUANTITY
Construction of Residential Accommodation for Faculty & Staff at Institute of Liver and Biliary Sciences (ILBS) at the risk and cost of previous agency
Code No. DESCRIPTION
SL.NO. UNIT QUANTITY DSR NDSR DSR NDSR
Material of Construction (M.O.C):
: Impeller — Stainless Steel
: Shaft — Stainless Steel
Motor: 2900 RPM; 3Ph 415V 50Hz
Insulation Class - B Min
Efficiency - IE2 Min.
Protection - IP44 Min.
AR on MR Supply, installation, testing and commissioning of electric pump control panel metal
clad cubicle type suitable for 230V AC single phase 50Hz supply system. The panel
shall be completely compartmentalised and complete with relays, contactors,
starters, sequential pump controller, Bus Bars, designation labels as per requirement,
continuous earth bar, panel separators, protective screens, cable clamping support
system, top/bottom cable gland plates for incoming and out going cable entries as
per details given below:
Sequential pump controller is to keep both pumps operational but with one remaining
standby at any particular moment.
Note: The start stops operation of the pumps shall be controled with magnetic
float type level sensors in the treated water tank. The control cabling between
sensors and the panel will be paid separately as per the actual measurement
under a separate item.
There shall be an audio visual alarm in case any pump fails to start.
32A FP 10 KA MCB - 1 No.
A set of 63 A 415V 50Hz 3 Phase four wire copper busbars.
INSTRUMENTS FOR INCOMER
— Ammeter 0-32A with Selector Switch
( including a set of CTs 32/5A)
— Voltmeter 0-500V with selector switch.
— A set of phase indicating light with
INSTRUMENTS ON OUTGOINGS
— Ammeter with selector switch for each
— Indication lights for ON-OFF-TRIP indication for each pump
Selector switch for auto/manual mode selection for the pumping system
OUTGOING FEEDERS
20A 10KA TP MCB 2.0HP DOL starter, overload relay, single phase preventer, timer Set 1.00 46658.46 0.00 46658.46
etc. - 2 Nos. Dry run protection with sensor complete as required.
16A 10KA DP MCB - 2 Nos.
Note: Switchgear and starter ratings are indicative. The Tenderer shall quote for
the actual rating required as per the pump model proposed by him.
CABLING AND MAIN PANEL
AR on MR Supplying and fixing of following types and sizes of 1.1 KV grade PVC insulated
conductor armoured cable conforming to IS : 1554.
a) 3C 2.5 sq.mm. Copper conductor M 50.00 186.63 0.00 9331.50
b) 4C 4 sq.mm. Copper conductor M 30.00 311.06 0.00 9331.80
AR on MR Supplying, laying & terminating of following types and size of 1.1 KV grade PVC
isulated armoured control cables conforming to IS : 1554 Part-II
AR on MR Supplying and making end termination with brass double compression glands and
copper/aluminium lugs for following size of PVC insulated and PVC sheathed/XLPE
copper/aluminium conductor cable of 1.1 KV grade as required :
a) 3C 2.5 sq.mm. Copper conductor Set 4.00 97.21 0.00 388.84
b) 4C 4 sq.mm. Copper conductor Set 2.00 194.41 0.00 388.82
c) 4C 16 sq.mm. `Al' conductor Set 12.00 256.62 0.00 3079.44
AR on MR Providing and fixing following size G.I. strip / wire on surface or in recess for body
earthing of motors as required.
AR on MR Supply, fabricating and installing following size of perforated M.S. powder coated (of
approved shade) (0.65 micron) cable trays including horizontal and vertical bends,
345 reducers, tees, cross members and other accessories as required and duly
suspended from the ceiling with M.S. suspenders and including painting etc. as
a) 100 mm. width x 40 mm. depth x 1.6 mm. thickness M 30.00 388.82 0.00 11664.60
ANUJ NAVNEET Digitally signed by ANUJ
CHACHA Date: 2023.01.10
BILL OF QUANTITY
Construction of Residential Accommodation for Faculty & Staff at Institute of Liver and Biliary Sciences (ILBS) at the risk and cost of previous agency
Code No. DESCRIPTION
SL.NO. UNIT QUANTITY DSR NDSR DSR NDSR
b) 150 mm. width x 50 mm. depth x 1.6 mm. thickness M 20.00 544.35 0.00 10887.00
c) 300 mm. width x 50 mm. depth x 1.6 mm. thickness M 10.00 699.88 0.00 6998.80
AR on MR Supply, installation, testing and commissioning of electric pump control panel metal
clad cubicle type suitable for 440V AC three phase 50Hz supply system. The panel
shall be completely compartmentalised and complete with Aluminium Bus Bars,
346 designation labels as per requirement, continuous Aluminium earth bar 40mm x 6
mm, panel separators, protective screens, cable clamping support system,
top/bottom cable gland plates for incoming and out going cable entries as per details
MAIN PANEL WATER PUMPING SYSTEM
100 A 36KA FP MCCB with phase spreader and extended rotary handles - 1 No.
A set of 160 A 415V 50Hz TPN 3 Ph 4 wire aluminium busbars. C./D. 1 Amp/ mm2.
INSTRUMENTS FOR INCOMER
A set of instrumentation with a set of Current transformer 100/5A with Ammeter 0-
100A, Selector Switch, Voltmeter 0-500V with selector switch, a set of phase
indicating lights with mcb fuses and energy meter (KWH).
OUTGOING FEEDERS
25A DP 10KA MCB - 2 No.
32A DP 10KA MCB - 2 No.
32A FP 10KA MCB - 10 No.
PIPE WORK AND VALVES
AR on MR Providing, fixing, jointing, testing and commissioning Medium Duty Class (Class B)
G.I. Pipe work conforming to IS:1239 (Part I)-1990 for pipes upto 150 mm dia. with all
fittings, flanges, specials & clamps effecting proper connections, including painting
347 with two coats of epoxy paint of approved quality and shade over a coat of primer on
exposed pipework, complete in all respects: (Pipe work restricted within the plant
room for suction and delivery headers and delivery pipe of submersible pumps)
AR on MR Providing and fixing butterfly valve of approved make including a set of MS flanges,
348 required nos. of nut & bolts all complete and as per following specification:
Body - Cast Iron
Shaft - Carbon Steel / Stainless Steel
Body Liner - EPDM/ nitrile rubber
Disc - Epoxy coated C.I./ D.I.
AR on MR Providing and fixing Dual plate (Wafer type) check valve (non return valve) of Class
PN 16, having cast iron body, stainless steel disc ( AISI 316), trim and spring of
approved make. including a set of MS flanges, required nos. of nut & bolts all
AR on MR Providing and fixing of flanged C.I (Pot) strainer on suction ends submerged in water
tanks, all complete.
AR on MR Providing and fixing of flanged end Pot strainer in cast iron body with stainless steel
perforated sheet screen basket, complete with drain plug.
AR on MR Providing and fixing screwed end Wafer type check valve (non return valve) of Class
352 PN 10, having stainless steel body and disc, trim and spring of approved make. all
AR on MR Providing, fixing, testing and commissioningof Full Bore Ball Valves of approved
Body : Nickel plated brass
Ball : Chrome plated brass
Operating Handle : Aluminium Painted
Pressure Rating : Minimum 20 Bar
Temerature Withstanding : 900 C Min.
ANUJ NAVNEET Digitally signed by ANUJ
CHACHA Date: 2023.01.10
BILL OF QUANTITY
Construction of Residential Accommodation for Faculty & Staff at Institute of Liver and Biliary Sciences (ILBS) at the risk and cost of previous agency
Code No. DESCRIPTION
SL.NO. UNIT QUANTITY DSR NDSR DSR NDSR
AR on MR Providing and fixing pressure reducing valve, suitable for water application and
having following features:
Body — Forged Brass / Bronze
Seat — Stainless Steel
Ends — Female Screwed Ends
Maximum Working Pressure — Upto 16 bar
Adjustable Pressure Range — 1.0 bar (Minimum) - 6.0 bar
Provision for installing Pressure Gauge : 1/4 inch port
AR on MR Providing and fixing heavy duty resilient rubber neoprene lined single arch vibration
355 eliminators suitable for raw water up to 70 deg.C temperature, pressure upto 15 Bar
and vacuum rating upto 700 mm Hg.
AR on MR Supplying, installation, setting, testing and commissioning of differential type pressure
356 switches with pressure dampening device of size 100 mm dia for operation of pumps. No. 4.00 1788.57 0.00 7154.28
AR on MR Supplying, installation, setting, testing and commissioning of glycerin filled pressure
357 gauge with pressure dampening device and isolation cock, all complete No. 6.00 1399.75 0.00 8398.50
AR on MR Providing and fixing level indicator assembly for water tanks comprising 2 nos. 15
mm dia gunmetal level guage isolation cocks with screwed ends, heavy guage
3358 transparent polythelyne tube of upto 6.0 m length, 100 mm wide x 20 mm thick teak Set 4.00 2410.69 0.00 9642.76
wood indicating board painted with level indications in cms and litres, as required.
AR on MR Providing, fixing, testing and commissioning of Electro Magnetic Flow Transmeter
with Communication Port, of approved makes.
Suitability: Fresh Water
Body : Non-corrosive
Flanges : Stainless Steel
Electrode : Stainless Steel
Coil Housing : Stainless Steel
Pressure Rating : Minimum 10 Bar
Temerature Withstanding : upto 850 C
Display: LCD showing both flow rate and totalised flow
Communication Port: RS 485
a) 40 mm dia nominal bore No. 1.00 42770.26 0.00 42770.26
b) 50 mm dia nominal bore No. 1.00 50546.67 0.00 50546.67
c) 65 mm dia nominal bore No. 1.00 58323.08 0.00 58323.08
d) 80 mm dia nominal bore No. 1.00 66099.49 0.00 66099.49
Total : Sub Head No. 7 Rs. 0.00 4680123.36
Sub Head 8 : SEWAGE TREATMENT AND RECYCLING PLANT
NOTE: The Vendor has to get the technical data sheets of all the equipment and
the machinery approved from the Consultant before commencing the the work
AR on MR "Designing, Supplying, installing, testing and commissioning of the 120 KLD Sewage
Treatment And Recycling Plant based on (i) Membrane Bio Reactor (MBR)
360 Technology for sewage treatment, (ii) Biological nutrient removal process", as per the Job 1.00 3499384.82 0.00 3499384.82
requirements given below and as described in the attached 'Scope of Work'
Expected raw sewage and Desired treated effluent characteristics: as described in
Reuse of treated effluent: as described in scope of work
The STP plant shall comprise of :
(i) Stainless Steel Perforated Screen/ Fine Screen (Grade SS-304) suitable for
handling peak flow of Raw Domestic Sewage into the equalization tank
(ii) Raw Sewage Lift Pumps - 2 nos. (1 working + 1 standby) as described in scope of
(iii) All media whether synthetic or live bio-mass including enzymes etc.
(iv) Pumps, motors, blowers, dosing pumps etc. (all pumps and blowers shall be 02
nos. i.e. 1 working + 1 standby).
(v) All Aeration, MBR Module, Anoxic treatment units
(vi) All Sludge handling units (common with primary treatment of STP)
(vii) Water quality Monitoring and Testing Equipment: pH meter and electromagnetic
(viii) Complete Interconnecting pipe work as described in the scope of work
(ix) Complete Power and control cabling as described in the scope of work
(x) Electric Control Panel: as described in the scope of work
(xi) Automation: The major operations of the plant shall be automatic controlled by
level switches, timers and other sensors
(xii) Pumps and Equipment skid, access platforms, ladders, safety railing etc.
(xiii) General: The packaged plant shall have all weather engineering, neatly finished
and painted, operation and maintenance friendly. All vessels and equipment shall be
properly labelled.
ANUJ NAVNEET Digitally signed by ANUJ
CHACHA Date: 2023.01.10
BILL OF QUANTITY
Construction of Residential Accommodation for Faculty & Staff at Institute of Liver and Biliary Sciences (ILBS) at the risk and cost of previous agency
Code No. DESCRIPTION
SL.NO. UNIT QUANTITY DSR NDSR DSR NDSR
(xiv) Obtaining statutory approvals from Local Pollution Control Board. However, the
statutory fee, if any, shall be born by the Client.
Total : Sub Head No. 8 Rs. 0.00 3499384.82
FIRE FIGHTING SYSTEM
Sub Head 1 : FIRE FIGHTING INSTALLATION
AR on MR Providing, laying, jointing, testing and commissioning of fire mains buried in ground
including coating and wrapping, earthwork in excavation in all kinds of soil and
refilling, providing thrust blocks in cement concrete 1:2:4 on all bends, tees and
junctions etc. as required, complete in all respects.
Material: M.S pipe Class 'C' conforming to IS:1239
Fittings: Heavy Class MS fittings suitable for butt welding and flanged joints.
Protection: Protection of buried pipe work shall be with polymeric corrosion
protection tape (minimum 4 mm thick) conforming to IS: 10221, coating and
wrapping as per manufacturer`s recommendations
AR on MR Providing, laying, jointing, testing and commissioning of fire mains above ground
mounted on concrete pedestals, walls, over head pipe racks etc. including clamping
system as described below. Quoted price shall include the following: Cost for
pipework support system shall be included in the rates.
Pipe Material: M.S pipe Class 'C' conforming to IS:1239
Fittings: Heavy Class MS fittings suitable for butt welding and flanged joints.
Supporting and Clamping System: Supporting and Clamping System is limited
to suitable size brackets, saddles etc.; fasteners for fixing the brackets and
saddles to the main structure; pipe clamps, bolts, nuts etc. Supporting and
Clamping system shall be modular and adjustable using preformed, pre-
galvanized steel elements and suitable fasteners requiring no welding at site
and complete in all respects.
Note: The required pedestals, steel frames, steel racks etc. shall be constructed/
fabricated and fixed by either a third party appointed by the Owner or paid
separately if mentioned under relevent items described elsewhere in this
Painting: Pipe work shall be painting with two coats of enamel paint / PU paint
of fire red shade over a coat of suitable primer.
363 16.10 CONDENSER WATER PIPE
16.10.1 Supplying, fixing, testing and commissioning of condenser water pipes of following
sizes of MS 'C' class along with necessary clamps, vibration isolators and fittings such
as bends,tees etc.but excluding valves, strainers, gauges etc. adequately supported
on rigid supports duly painted/buried in ground excavation and refilling etc. as per
specification and as required complete in all respect.
Note:-The Pipes size 150mm & below shall be M.S. 'C' class as per IS : 1239 and
pipes size above 150mm shall be welded black steel pipe heavy class as per IS:
3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. And from
minimum 7mm thick MS sheet for pipes of 400 mm dia and above.
Pipe work for Internal / Exposed Hydrant System
AR on MR Providing, laying, jointing, testing and commissioning pipe work for Internal / Exposed
Hydrant System including fixing of pipe work on walls, beams, slabs, columns etc.
with M. S. supports (duly painted), adjustable hangers, complete in all respects.
Material: M.S pipe Class 'C' conforming to IS:1239 for pipes upto 150 mm dia
and IS:3589-1991 for pipes above 150 mm dia.
Fittings: Heavy Class MS fittings for pipes above 50 mm dia suitable for butt
welding and flanged joints.
Painting: Pipe work shall be painting with two coats of enamel paint of fire red
shade over a coat of primer.
18.10 Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and
making good the walls etc.
Internal work - Exposed on wall
AR on DSR Painting M.S./ G.I. pipes and fittings with two coats of enamel paint of fire red shade
over a coat of primer, both of approved quality for new work :
c) 25 mm dia nominal bore M 100.00 15.55 0.00 1555.00
ANUJ NAVNEET Digitally signed by ANUJ
CHACHA Date: 2023.01.10
BILL OF QUANTITY
Construction of Residential Accommodation for Faculty & Staff at Institute of Liver and Biliary Sciences (ILBS) at the risk and cost of previous agency
Code No. DESCRIPTION
SL.NO. UNIT QUANTITY DSR NDSR DSR NDSR
16.11 Supplying, fixing, testing and commissioning of following valves, gauges and strainers
for condenser water circulation as per specifications.
16.11.1 BUTTERFLY VALVE (MANUAL) with C I body SS disc nitrile sheet & O - ring & PN 16
pressure rating as specified.
16.11.2 NON - RETURN VALVE with dual plate of C I body SS plates vulcanized NBR seal
flanged end & PN 16 pressure rating as specified.
AR on MR Providing and fixing of nickel plated brass/ nonferrous alloy fullyway ball valve (
369 minimum working pressure of 20 bar ) with operating handle as per specification and
of approved make.
AR on MR Providing and fixing stainless steel (grade AISI 304) single headed landing valve
(hydrant) conforming to IS : 5290 - 1993 with 63 mm female instantaneous outlet
connection with blank caps and chains conforming to IS: 903 all complete
AR on MR Providing and fixing impact, abrasion and weathering resistant rubberised fabric lined
(RRL) hose pipe conforming to IS : 636-1979 (Type -2) of 63 mm dia and 15 m length
with stainless steel (grade AISI 304) instantaneous male and female couplings
conforming to IS: 903-1975 (for internal hydrants)
AR on MR Providing and fixing Controlled Percolating (CP) Hose ISI marked (IS:8423) 63 mm
dia x 15 m long complete with instantaneous type stainless steel (grade AISI 304) 63
372 mm dia, ISI marked Male & Female couplings (IS:903) bound and riveted to hose pipe No. 34.00 3032.80 0.00 103115.20
with copper rivets and 1.5 mm copper wire. (For external hydrants)
16.8 Providing and fixing in position the industrial type pressure gauges with gun metal /
brass valves complete as required
AR on MR Providing and fixing swinging type first aid fire hose reel comprising 20 mm dia 36 m
long thermoplastic reinforced hose reel tubing conforming to IS :12585 Type-2, MS
374 drum with fixing bracket conforming to IS:884 and with 5 mm dia stainless steel No. 63.00 7465.35 0.00 470317.05
(grade AISI 304) shut off nozzle conforming to IS:8090, all complete
AR on MR Providing and fixing stainless steel (grade AISI 304) branch pipe nozzle conforming to
375 IS : 903, suitable for instantaneous connections to hose coupling etc. as required: No. 80.00 2566.22 0.00 205297.60
AR on MR Providing and fixing standard Fireman's Axe with heavy insulated rubber handle.
AR on MR Providing, fabricating and fixing single/ double leaf door with frame only for all internal
fire hydrants fabricated from MS sections, welded construction, having glazed panels
with reinforced glass, integral three point locking arrangement, stove enamelled fire
377 red finish with "FIRE HOSE" written on front, suitable to house two nos.15m lengths of
canvas hose with couplings, 1 no. branch pipe and 1 no. first aid fire hose reel along
with the landing valve all complete.
a) Size 1300x1800 mm ( approximate) No. 1.00 5832.31 0.00 5832.31
AR on MR Providing and fixing weather proof outdoor type hose cabinet made of not less than
1.5 mm CRCA MS sheet having glazed door, locking arrangement, painted with two
378 coats of enamel paint over a coat of primer and of size suitable to accomodate two
nos. 15 m lengths of 63 mm dia RRL hose pipe and branch pipe.
AR on MR Providing, fixing and testing forged brass 25 mm dia screwed inlet single acting air
379 release valve with 25 mm dia ball valve on inlet side and pressure gauge with No. 5.00 1866.34 0.00 9331.70
isolating cock.
AR on MR Providing and fixing Cast Iron flanged and swing type foot valve with rubber seats,
380 complete with bolts, nuts, rubber insertions etc. all complete (as per IS:4038) for two
way collecting head
AR on MR Providing and fixing gun metal delivering/ dividing/ collecting 63 mm dia breachings of
381 instantaneous patern complete with blank cap and chain, 150 mm dia flanged inlet
conforming to IS:904/IS:905, as the case may be.
a) Four way breaching inlet with built in check valve. No. 1.00 10109.33 0.00 10109.33
b) Four way breaching inlet No. 1.00 10109.33 0.00 10109.33
c) Two way collecting head. No. 2.00 7776.41 0.00 15552.82
19.35 Providing and laying Non Pressure NP-3 class (Medium duty) R.C.C. pipes including
collars/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1
cement : 2 fine sand) including testing of joints etc. complete
ANUJ NAVNEET Digitally signed by ANUJ
CHACHA Date: 2023.01.10
BILL OF QUANTITY
Construction of Residential Accommodation for Faculty & Staff at Institute of Liver and Biliary Sciences (ILBS) at the risk and cost of previous agency
Code No. DESCRIPTION
SL.NO. UNIT QUANTITY DSR NDSR DSR NDSR
AUTOMATIC SPRINKLER SYSTEM
AR on MR Providing and fixing of brass body quartzoide bulb type automatic sprinkler heads set
to operate at specified temperature and having k-factor as per design requirements of
following types. Sprinkler heads shall be complete with deflector.( UL Listed and FM
a) Type : Pendent type
Size : 15 mm dia
Operating Temp. : 68 deg.C.
Response : Standard response
d) Type : Pendent type
Size : 15 mm dia
Operating Temp. : 79 deg.C.
Response : Standard response
e) Type : Pendent type
Size : 15 mm dia
Operating Temp. : 93 deg.C.
Response : Standard response
b) Type : Upright type
Size : 15 mm dia
Operating Temp. : 68 deg.C.
Response : Standard response
h) Type : Upright type
Size : 15 mm dia
Operating Temp. : 79 deg.C.
Response : Standard response
i) Type : Side wall type
Size : 15 mm dia
Operating Temp. : 68 deg.C.
Response : Standard response
j) Type : Side wall type Extended
Operating Temp. : 68 deg.C.
Response : Standard response
AR on MR Providing and fixing following type of rosette for sprinklers, of approved make. (UL
Listed and FM Approved)
a) Two piece adjustable rosettes
385 16.10 CONDENSER WATER PIPE
16.10.1 Supplying, fixing, testing and commissioning of condenser water pipes of following
sizes of MS 'C' class along with necessary clamps, vibration isolators and fittings such
as bends,tees etc.but excluding valves, strainers, gauges etc. adequately supported
on rigid supports duly painted/buried in ground excavation and refilling etc. as per
specification and as required complete in all respect.
Note:-The Pipes size 150mm & below shall be M.S. 'C' class as per IS : 1239 and
pipes size above 150mm shall be welded black steel pipe heavy class as per IS:
3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. And from
minimum 7mm thick MS sheet for pipes of 400 mm dia and above.
Pipe work for Sprinkler System
AR on MR Providing, laying, jointing, testing and commissioning pipe work for Sprinkler System
including fixing of pipe work on walls, beams, slabs, columns etc. with M. S. supports
(duly painted), adjustable hangers, complete in all respects.
Material: M.S pipe Class 'C' conforming to IS:1239 for pipes upto 150 mm dia
and IS:3589-1991 for pipes above 150 mm dia.
Fittings: Heavy Class MS fittings for pipes above 50 mm dia suitable for butt
welding and flanged joints.
Painting: Pipe work shall be painted with two coats of enamel paint of fire red
shade over a coat of primer.
18.10 Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and
making good the walls etc.
Internal work - Exposed on wall
AR on DSR Painting M.S./ G.I. pipes and fittings with two coats of enamel paint of fire red shade
over a coat of primer, both of approved quality for new work :
c) 50 mm dia nominal bore M 480.00 31.11 0.00 14932.80
d) 40 mm dia nominal bore M 220.00 23.33 0.00 5132.60
e) 32 mm dia nominal bore M 310.00 19.44 0.00 6026.40
f) 25 mm dia nominal bore M 3310.00 15.55 0.00 51470.50
ANUJ NAVNEET Digitally signed by ANUJ
CHACHA Date: 2023.01.10
BILL OF QUANTITY
Construction of Residential Accommodation for Faculty & Staff at Institute of Liver and Biliary Sciences (ILBS) at the risk and cost of previous agency
Code No. DESCRIPTION
SL.NO. UNIT QUANTITY DSR NDSR DSR NDSR
AR on MR Providing and fixing 1.0 metre long braided stainless steel (grade AISI 304) flexible
tubing suitable for fire sprinkler installation having 1" NPT mail thread inlet and 1/2"
389 NPT female thread outlet. The unit shall be complete with bracket assembly for No. 25.00 933.17 0.00 23329.25
securly fixing on false ceiling. The product shall be UL Listed and FM Approved.
AR on MR Providing and fixing butterfly valve with supervisory switch (weather proof and temper
resistant), factory assembled of approved make including a set of MS flanges,
required nos. of nut & bolts all complete and as per following specification:
Body - Cast Steel/ Ductile Iron
Shaft - Carbon Steel / Stainless Steel
Body Liner - EPDM/ nitrile rubber
Disc - Epoxy coated Ductile Iron
AR on MR Providing, fixing, testing and commissioning of Full Bore Ball Valves of approved
Body : Nickel plated brass
Ball : Chrome plated brass
Operating Handle : Aluminium/ Steel with protective colour coded sleeve
Pressure Rating : Minimum 20 Bar
Temerature Withstanding : 900 C Min.
AR on MR Providing and fixing of installation valve assembly of approved make complete with
turbine type automatic alarm valve, control valve, test and drain valve and hydraulic
392 alarm with motor and gong including interconnectig piping all complete as per
specification and of approved make. (UL Listed and FM Approved)
AR on MR Providing and fixing 25 mm dia Brass/ Bronze body test and drain valve assembly
393 including isolation valve, sight glass and making threaded connection with drain line Set 4.00 5832.31 0.00 23329.24
(UL Listed and FM Approved).
16.8 Providing and fixing in position the industrial type pressure gauges with gun metal /
brass valves complete as required
AR on MR Providing, fixing and testing forged brass 25 mm dia screwed inlet single acting air
395 release valve with 25 mm dia ball valve on inlet side and pressure gauge with Nos. 4.00 2021.87 0.00 8087.48
isolating cock.
AR on MR Providing and fixing electric flow switch with mechanical time delay feature, capable
396 of sensing a minimum of flow of one sprinkler, including making electrical cable
termination. (UL Listed and FM Approved)
a) For 150 mm dia branch sprinkler pipe Nos. 4.00 5443.49 0.00 21773.96
b) For 100 mm dia branch sprinkler pipe No. 1.00 5054.67 0.00 5054.67
AR on MR Supplying and fixing following lockable cabinets for storing spare sprinklers,
fabricated from 1.5 mm thick CRCA MS sheet, stove enamelled in fire red shade with
full front glass door, complete with required no. of 68 degree centigrade operating
temperature sprinklers and 1 no. sprinkler spanner.
a) with 24 Nos. Pendent Type Sprinklers Set 1.00 7776.41 0.00 7776.41
b) with 24 Nos. Upright Type Sprinklers Set 1.00 7776.41 0.00 7776.41
AR on MR Providing, laying, jointing, testing and commissioning of pipe work for Water Curtain
including clamping system as described below. Quoted price shall include the
398 following: Cost for pipework support system shall be included in the rates.
Pipe Material: M.S pipe Class 'C' conforming to IS:1239
Fittings: Heavy Class MS fittings suitable for butt welding and flanged joints for
pipes 50 mm and above in diameters, For pipework upto 40 mm dia, UL and FM
approved ductile iron fittings suitable for threaded joints
Supporting and Clamping System: Supporting and Clamping System is limited
to suitable size brackets, saddles etc.; fasteners for fixing the brackets and
saddles to the main structure (wall, beam, slab, column etc.); pipe clamps,
bolts, nuts etc. Supporting and Clamping system shall be modular and
adjustable using preformed, pre-galvanized steel elements and suitable
fasteners requiring no welding at site and complete in all respects.
Painting: Pipe work shall be painting with two coats of enamel paint of fire red
shade over a coat of primer.
Firestops: For all horizontal and vertical crossings of building structure (slabs,
walls, beams, column etc) pvc pipe sleeves of dia atleast 30 mm more than the
dia of the pipe to be passed through shall be fixed in the building structure, the
space between the the sleeve and the structure shall be made good. The
annular space between the pipe and the sleeves shall be sealed (upto a
minimum depth 25 mm) with fire resistant acrylic based sealent of approved
make and quality.
ANUJ NAVNEET Digitally signed by ANUJ
CHACHA Date: 2023.01.10
BILL OF QUANTITY
Construction of Residential Accommodation for Faculty & Staff at Institute of Liver and Biliary Sciences (ILBS) at the risk and cost of previous agency
Code No. DESCRIPTION
SL.NO. UNIT QUANTITY DSR NDSR DSR NDSR
AR on MR Providing, laying, jointing, testing and commissioning of pipe work for Water Curtain
including clamping system as described below. Quoted price shall include the
399 following: Cost for pipework support system shall be included in the rates.
Material: G. I. pipe medium Class conforming to IS:1239 for pipes upto 150 mm
Fittings: Galvanized malleable iron fittings conforming to IS: 1879 suitable for
threaded joints
Supporting and Clamping System: Supporting and Clamping System is limited
to suitable size brackets, saddles etc.; fasteners for fixing the brackets and
saddles to the main structure (wall, beam, slab, column etc.); pipe clamps,
bolts, nuts etc. Supporting and Clamping system shall be modular and
adjustable using preformed, pre-galvanized steel elements and suitable
fasteners requiring no welding at site and complete in all respects.
Painting: Exposed Pipe work shall be painted with two coats of enamel paint of
fire red shade over a coat of primer.
Firestops: For all horizontal and vertical crossings of building structure (slabs,
walls, beams, column etc) pvc pipe sleeves of dia atleast 30 mm more than the
dia of the pipe to be passed through shall be fixed in the building structure, the
space between the the sleeve and the structure shall be made good. The
annular space between the pipe and the sleeves shall be sealed (upto a
minimum depth 25 mm) with fire resistant acrylic based sealent of approved
make and quality.
AR on MR Providing and fixing butterfly valve with supervisory switch (weather proof and temper
resistant), factory assembled of approved make including a set of MS flanges,
required nos. of nut & bolts all complete and as per following specification:
Body - Cast Steel/ Ductile Iron
Shaft - Carbon Steel / Stainless Steel
Body Liner - EPDM/ nitrile rubber
Disc - Epoxy coated Ductile Iron
AR on MR Providing, fixing, testing and commissining factory assembled packaged `Deluge
System comprising Deluge Valve with Electric Actuator System (Solenoid Valve,
Pressure Switches etc), Drain Valve Priming Connection, Drip Check Valve,
Emergency Release Valve, Sprinkler Alarm Bell with test valve, Pressure Gauges etc.
The system shall be complete in all respect including System Control Panel
compatible with detection system being provided at site, interconnecting pipework,
valves, cabling, powder coated cabinet etc.
AR on MR Supply, installation, testing and commissioning of Digital technology based power
402 supply units highly regulated and spikes free terminal voltage and heavy sourcing
current for regulated terminal voltage.
Input : 220V 50Hz AC
AR on MR Providing and fixing of brass body open nozzle for water curtain system (UL Listed
and FM Approved)
a) Size : 15 mm dia
AR on MR Supplying and fixing of ISI marked MS conduits (IS:9537 Part-II) alongwith the
404 accessories in surface/recess including cutting the wall and making good the same in
case of recessed conduit as required :
AR on MR Supplying, laying and connecting of following size 1.1 kV grade copper conductor
control cable (conforming to IS:1554 Part I) on wall or on existing cable tray/ in
existing pipe/trench with clamping, dressing or drawn in existing ducts all as
a) 2C 1.5 sq.mm.armoured cable M 180.00 69.99 0.00 12598.20
FIRE EXTINGUISHERS
Note : All fire extinguishers shall be ISI marked
AR on MR Providing and fixing fully charged ABC powder type portable fire extinguishers
406 conforming to IS:15683, fixed to wall with brackets complete with initial charge.
ANUJ NAVNEET Digitally signed by ANUJ
CHACHA Date: 2023.01.10
BILL OF QUANTITY
Construction of Residential Accommodation for Faculty & Staff at Institute of Liver and Biliary Sciences (ILBS) at the risk and cost of previous agency
Code No. DESCRIPTION
SL.NO. UNIT QUANTITY DSR NDSR DSR NDSR
AR on MR Providing and fixing fully charged foam type portable fire extinguishers conforming to
407 IS:15683, fixed to wall with brackets complete with initial charge.
AR on MR Providing and fixing fully charged CO2 type portable fire extinguishers with gas
408 cartridge all complete conforming to IS:15683, fixed to wall with brackets complete
with initial charge.
AR on MR Providing and fixing fully charged DCP type portable fire extinguishers with cartridge
409 all complete conforming to IS:15683, trolly mounted fire extinguisher complete with
initial charge.
AR on MR Providing & fixing 50 litre capacity, ISI marked, foam type trolly mounted fire
extinguisher complete with initial charge.
AR on MR Providing and fixing fully charged modular FE-36 clean agent type portable fire
extinguishers fixed to ceiling with brackets complete with initial charge.
AR on MR Providing and fixing clean agent based tube panel protection system to be mounted
on electrical panel with brackets complete
a) Main LT Panel - Approximate Size (L x W X H) - 12.0M X 1.2M X 2.3M No. 1.00 349938.48 0.00 349938.48
FIRE PUMPS & CONTROL PANELS
NOTES : 1) Pumps shall be capable of furnishing not less than 150% of rated
capacity at a head of not less than 65% of the rated head. The shut off head
shall not exceed 120% of rated head.
2) Valves on suction and delivery sides shall be paid seperately as per relevant items
in other subheads.
AR on MR Supplying, installing, testing and commissioning of following electric motor driven
pumping sets for fire fighting purposes including, making piping and electrical
connections and suitable for automatic operation. The pump set shall consist of /
complete with :
i) Horizontally mounted single / multistage end suction type pump of cast iron body
and having bronze impellors
ii) Squirrel cage TEFC induction motor suitable for 415V 3 phase 50 Hz AC supply of
HP rating suitable for the specified duty of pump with synchronous speed of 2900
iii) Common robust bed plate fabricated out of mild steel channel of appropriate size
with vibration damping arrangement fixed over suitably designed cement concrete
foundation block.
iv) Spacer type suitable coupling between pump and prime mover including sheet
metal coupling guard.
v) Mechanical seal for the pump
vi) One no. pressure gauge on delivery side with isolation cock.
vii) One no pressure switch and power cabling between panel and pressure switch.
viii) Drain outlet with valve.
ix) Drip tray with pipe connected to drain
a) Hydrant System Pump
Details of Equipment offered
(To be filled in by the tenderer)
b) Water Curtain Pump
Details of Equipment offered
(To be filled in by the tenderer)
c) Jockey Pump (Vertical inline)
Details of Equipment offered
(To be filled in by the tenderer)
M.O.C : Casing
ANUJ NAVNEET Digitally signed by ANUJ
CHACHA Date: 2023.01.10
BILL OF QUANTITY
Construction of Residential Accommodation for Faculty & Staff at Institute of Liver and Biliary Sciences (ILBS) at the risk and cost of previous agency
Code No. DESCRIPTION
SL.NO. UNIT QUANTITY DSR NDSR DSR NDSR
AR on MR Supplying, installing, testing and commissioning of following diesel engine driven
pumping sets for fire fighting purposes including, making piping and electrical
connections and suitable for automatic operation. The pump set shall consist of /
complete with :
i) Horizontally mounted single / multistage split casing suction type pump of cast iron
body and having bronze impellors
ii) Water cooled diesel engine capable of developing BHP suitable for the specified
duty of pump synchronous speed of 1800 RPM
iii) Common robust bed plate fabricated out of mild steel channel of appropriate size
with vibration damping arrangement fixed over suitably designed cement concrete
foundation block.
iv) Suitable coupling between pump and engine including sheet metal coupling guard.
v) Mechanical seal for the pump
vi) One no. pressure gauge on delivery side with isolation cock.
vii) Drain outlet with valve.
viii) Drip tray with pipe connected fo drain
ix) Automatic engine starting system including 24 volts, minimum 160 AH battery,
boost / trickle charger including battery mounting arrangement, battery leads and
other control cabling.
a) Standby diesel engine operated
Engine BHP at 1800 RPM - 133 BHP
Details of Equipment offered
(To be filled in by the tenderer)
M.O.C : Casing
BHP at 1800 RPM
415 CONDENSER WATER PIPE
16.10 Supplying, fixing, testing and commissioning of condenser water pipes of following
sizes of MS 'C' class along with necessary clamps, vibration isolators and fittings such
as bends,tees etc.but excluding valves, strainers, gauges etc. adequately supported
on rigid supports duly painted/buried in ground excavation and refilling etc. as per
specification and as required complete in all respect.
Note:-The Pipes size 150mm & below shall be M.S. 'C' class as per IS : 1239 and
pipes size above 150mm shall be welded black steel pipe heavy class as per IS:
3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. And from
minimum 7mm thick MS sheet for pipes of 400 mm dia and above.
Pipe work Pump Room
AR on MR Providing, laying, jointing, testing and commissioning of pipe work for pump room
including clamping system as described below. Quoted price shall include the
416 following: Cost for pipework support system shall be included in the rates.
Pipe Material: M.S pipe Class 'C' conforming to IS:1239 for pipes upto 150 mm
dia and IS:3589-1991 for pipes above 150 mm dia.
Fittings: Heavy Class MS fittings suitable for butt welding and flanged joints for
pipes 50 mm and above in diameters, For pipework upto 40 mm dia, UL and FM
approved ductile iron fittings suitable for threaded joints
Supporting and Clamping System: Supporting and Clamping System is limited
to suitable size brackets, saddles etc.; fasteners for fixing the brackets and
saddles to the main structure (wall, beam, slab, column etc.); pipe clamps,
bolts, nuts etc. Supporting and Clamping system shall be modular and
adjustable using preformed, pre-galvanized steel elements and suitable
fasteners requiring no welding at site and complete in all respects.
Painting: Pipe work shall be painting with two coats of enamel paint of fire red
shade over a coat of primer.
Firestops: For all horizontal and vertical crossings of building structure (slabs,
walls, beams, column etc) pvc pipe sleeves of dia atleast 30 mm more than the
dia of the pipe to be passed through shall be fixed in the building structure, the
space between the the sleeve and the structure shall be made good. The
annular space between the pipe and the sleeves shall be sealed (upto a
minimum depth 25 mm) with fire resistant acrylic based sealent of approved
make and quality.
ANUJ NAVNEET Digitally signed by ANUJ
CHACHA Date: 2023.01.10
BILL OF QUANTITY
Construction of Residential Accommodation for Faculty & Staff at Institute of Liver and Biliary Sciences (ILBS) at the risk and cost of previous agency
Code No. DESCRIPTION
SL.NO. UNIT QUANTITY DSR NDSR DSR NDSR
18.31 Providing and fixing C.I. sluice valves (with cap) complete with bolts, nuts, rubber
insertions etc. (the tail pieces if required will be paid separately) :
18.31.1 100 mm diameter
18.31.3 150 mm diameter
18.31.4 200 mm diameter
18.31.5 250 mm diameter
AR on MR Providing and fixing mechanical locking of sluice valve with leather strap and pad lock
AR on MR Providing and fixing temper and alarm switch complete with required mounting for
sluice valve complete as per specification and of approved make.
16.11.2 NON - RETURN VALVE with dual plate of C I body SS plates vulcanized NBR seal
flanged end & PN 16 pressure rating as specified.
AR on MR Providing, fixing, testing and commissioning of Full Bore Ball Valves of approved
Body : Nickel plated brass
Ball : Chrome plated brass
Operating Handle : Aluminium Painted
Pressure Rating : Minimum 20 Bar
Temerature Withstanding : 900 C Min.
AR on MR Providing and fixing of flanged end Pot/ Bucket type strainer in cast iron body with
422 stainless steel perforated sheet screen basket, complete with drain plug.
AR on MR Providing and fixing resilient rubber neoprene lined single arch vibration eliminators
423 suitable for raw water up to 70 deg.C temperature working pressure 16 Kg per square
16.8 Providing and fixing in position the industrial type pressure gauges with gun metal /
brass valves complete as required
AR on MR Supply, installation, testing and commissioning of suitably designed exhaust piping
system with residential type silencer to discharge engine gases to outside open air as
per site conditions. The exhaust piping shall be shall duly painted with two coats of
heat resistant aluminium paint and insulated with 50mm thick loose mineral wool,
covered with 3/4" chicken wire mesh and cladded with 24G aluminium sheet.
AR on MR Supply, installation, testing and commissioning of welded steel (minimum 2 mm thick
sheet) constructed fuel tank conforming to relevant I.S. standard having storage
capacity sufficient to allow the engine to run on full load for 6 hrs. but not less than 200
litres. including interconnecting fuel pipework valves and indicator system showing the
level of the fuel in the tank. The tank shall be mounted above the engine to provide a
gravity feed. A hand operated pump connected to the fuel tank shall also be provided
for transfering the fuel from the drum at floor level to the elevated storage tank.
AR on MR Supply, installation, testing and commissioning of fire control panel metal clad type
suitable for 415 V AC three phase 4 wire 50Hz supply system. The panel shall be
suitable for automatic operation of the fire pumps as per the specified parameters.
The panel shall be completely compartmentalised and complete with relays,
427 contactors, starters, Aluminium Bus Bars, designation labels as per requirement,
continuous earth bar, panel separators, protective screens, cable clamping support
system, top/bottom cable gland plates for incoming and out going cable entries as
per details given below:
400A 35KA TPN MCCB with rotary handles - 1 No.
A set of 500A 415V 50Hz 3 Ph 4 wire aluminium busbars.
INSTRUMENTS FOR INCOMER
A set of instrumentation with a set of Current transformer 400/5A with Ammeter 0-
400A, Selector Switch, Voltmeter 0-500V with selector switch and a set of phase-RYB
indicating lights with MCB and energy meter
ANUJ NAVNEET Digitally signed by ANUJ
CHACHA Date: 2023.01.10
BILL OF QUANTITY
Construction of Residential Accommodation for Faculty & Staff at Institute of Liver and Biliary Sciences (ILBS) at the risk and cost of previous agency
Code No. DESCRIPTION
SL.NO. UNIT QUANTITY DSR NDSR DSR NDSR
Provision for BMS connectivity. The panel should have sufficient no. of potential free
contacts for connectivity with Building Management System for monitoring purposes
INSTRUMENTS ON OUTGOINGS
A set of instrumentation with ammeter with selector switch and current transformer
Indication lights for ON-OFF indication for each fire pump
OUTGOING FEEDERS
For Hydrant Pump
315A TP 36KA MCCB with phase spreader with rotary handle, 120HP DOL starter,
overload relay, single phase preventer, timer etc. - 1No.
For Water Curtain Pump
100A TP 36KA MCCB with phase spreader with rotary handle, 25HP DOL starter,
overload relay, single phase preventer, timer etc. - 1No.
For Jockey Pump
63A TP 25KA MCCB with rotary handle, 10 HP DOL starter, overload relay, single
phase preventer, timer etc. - 1 No.
For Diesel Engine Operated Pump
AMF logic control for auto starting of the diesel engine operated pump when the
electric driven pumps fail to start. The control cubicle shall consist of MCBs, 12/24V
battery charger, DC ammeter and voltmeters , indicating lights , push buttons, hooter,
lockout timers, interlocking relay, fuel level indicators etc. as required.
Control wiring, auxiliary switches and timer for automatic starting and stopping of
Jockey and electric driven pump with externally mounted pressure switches. The
control wiring shall be done in such a way that the Jockey pump shall start when the
pressure falls to 9.5 Kg/sq.cm and stops at 10.5 Kg/sq.cm pressure and Main fire
pump shall start when the pressure drops below 8.5 Kg/sq.cm. and stops when the
pressure builds above 10.5 Kg/sq.cm. Jockey pump shall stop when the main pump is
working. Suitable timers shall be used for starting and stoping of the pumps
Note: Externally mounted pressure switches and interconnecting control cabling to be
paid seperatly.
AR on MR Providing, installing, testing and commissioning hydro-pneumatic vessel. The vessel
shall comprise of MS shell, suitable for a working pressure of minimum 12.0
kg/sq.cm., complete with mounting pedestals, 100 mm dia flanged inlet connection 25
mm dia drain connection, flanged openable cover, all complete. The vessel shall be
suitably treated with anticorrosive pain inside and epoxy paint of approved shade
The vessel as described above having following parameters
Height on Straight - 2000MM
Shell Thickness - 10 MM
Dishend Thickness - 12 MM
AR on MR Supplying of following types and sizes of 1.1 KV grade PVC insulated aluminium
conductor FRLS armoured cable conforming to IS : 1554.
7.8 Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power
cable of 1.1 KV grade of following size on cable tray as required.
a 7.8.1 Upto 35 sq. mm (clamped with 1mm thick saddle M 20.00 25.66 513.20 0.00
7.8.2 Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)
7.8.3 Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)
9.1 Supplying and making end termination with brass compression gland and aluminium
431 lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium
conductor cable of 1.1 KV grade as required.
AR on MR Supplying of following types and size of 1.1 KV grade PVC isulated armoured control
cables conforming to IS : 1554 Part-II
7.8 Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power
cable of 1.1 KV grade of following size on cable tray as required.
7.8.1 Upto 35 sq. mm (clamped with 1mm thick saddle M 50.00 25.66 1283.00 0.00
7.7 Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power
cable of 1.1 KV grade of following size on wall surface as required.
7.7.1 Upto 35 sq. mm (clamped with 1mm thick saddle M 50.00 30.33 1516.50 0.00
ANUJ NAVNEET Digitally signed by ANUJ
CHACHA Date: 2023.01.10
BILL OF QUANTITY
Construction of Residential Accommodation for Faculty & Staff at Institute of Liver and Biliary Sciences (ILBS) at the risk and cost of previous agency
Code No. DESCRIPTION
SL.NO. UNIT QUANTITY DSR NDSR DSR NDSR
5.9 Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip
earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer
etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt
& spring washer spaced at 50mm)
5.11 Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth
436 electrode including connection with G.I. nut, bolt, spring, washer excavation and re- M 20.00 375.60 7512.00 0.00
filling etc. as required.
5.15 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections
etc. as required.
5.16 Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as
4.1 Supplying and installing following size of perforated painted with powder coating M.S.
cable trays with perforation not more than 17.5%, in convenient sections, joined with
connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts,
painting suspenders etc as required
a 4.1.1 100 mm width X 50 mm depth X 1.6 mm thickness M 20.00 370.16 7403.20 0.00
b 4.1.2 150 mm width X 50 mm depth X 1.6 mm thickness M 20.00 412.93 8258.60 0.00
c 4.1.4 300 mm width X 50 mm depth X 1.6 mm thickness M 10.00 482.92 4829.20 0.00
4.2 Supplying and installing following size of perforated painted with powder coating M.S.
cable trays bends with perforation not more than 17.5%,, joined with connectors,
suspended from the ceiling with M.S. suspenders including bolts & nuts, painting
suspenders etc as required.
a 4.2.1 100 mm width X 50 mm depth X 1.6 mm thickness Each 5.00 628.33 3141.65 0.00
b 4.2.2 150 mm width X 50 mm depth X 1.6 mm thickness Each 5.00 736.43 3682.15 0.00
c 4.2.4 300 mm width X 50 mm depth X 1.6 mm thickness Each 3.00 1042.04 3126.12 0.00
4.3 Supplying and installing following size of perforated painted with powder coating M.S.
cable trays Tee with perforation not more than 17.5%, joined with connectors,
suspended from the ceiling with M.S. suspenders including bolts & nuts, painting
suspenders etc as required.
a 4.3.1 100 mm width X 50 mm depth X 1.6 mm thickness Each 2.00 706.88 1413.76 0.00
b 4.3.2 150 mm width X 50 mm depth X 1.6 mm thickness Each 2.00 833.63 1667.26 0.00
c 4.3.4 300 mm width X 50 mm depth X 1.6 mm thickness Each 1.00 1204.57 1204.57 0.00
AR on MR Supplying, installation, setting, testing and commissioning of M.S. pipe manifold
(fabricated with materials as specified in Item no. 9.5.3 above) required nos. of
442 pressure switches of suitable pressure rating, NO + NC contacts suitable for 220 volts
5 amp, isolating valves, drain valves assembly as per standard detail
a) Manifold for 3 pumps Set 1.00 11664.62 0.00 11664.62
Maximum pressure of the system 10.5 Kg/sq.cm.
Total : Sub Head No. 9 Rs. 5409734.74 8255869.88
MECHANICAL VENTILATION FOR BASEMENT & PRESSURIZATION SYSTEM
1.1 VANE AXIAL FANS
Supply, Installation, Testing and Commissioning of axial flow fans (Vane axial type)
complete with MS casing, impeller and flame proof motor with class 'F" insulation for
make - up air system and class "H" insulation for smoke evacuation system as shown
in the drawings and as per the specifications. Fans with class "H" motors should be
suitable for operating for mimimum 2 Hrs at 250-300 degC temp. Fan Casing should
be provided with Special Designed Integral Straightening Vanes to reduce
turbulence, provide high performance & low noise level. Axial fans shall be suitable
for operation on 415±10% volts, 50Hz, 3 phase AC power supply. Axial flow fans
shall be provided with inlet and outlet cones fabricated at site using GS sheet having
thickness not less than 20G and necessary vibration isolation arrangement including
spring type vibration isolators and rubber groumet etc. as required. Fans shall be IP-
55 rated. All fans should be AMCA certified. Motor shall be IE-2 type.
Fan Capacity S.P Motor Area being Fan
No. (Cfm) (mmWG) Rating/Class fed Dia/RPM
Class'H' Normal/Smoke Exhaust
Class'H' Normal/Smoke Exhaust
Class'H' Normal/Smoke Exhaust
Maximum Noise Level for above fans shall not exceed 75dBA@3M
1.2 TUBE AXIAL FANS
ANUJ NAVNEET Digitally signed by ANUJ
CHACHA Date: 2023.01.10
BILL OF QUANTITY
Construction of Residential Accommodation for Faculty & Staff at Institute of Liver and Biliary Sciences (ILBS) at the risk and cost of previous agency
Code No. DESCRIPTION
SL.NO. UNIT QUANTITY DSR NDSR DSR NDSR
Supply, Installation, Testing and Commissioning of axial flow fans (tube axial type)
complete with MS casing, impeller, flame proof motor with class 'F" insulation for
make - up air system and class "H" insulation for normal and smoke evacuation of
basement as shown in the drawings and as per the specifications. Fans with class
"H" motors should be suitable for operating for mimimum 2 Hrs at 250-300 degC
temp. Axial fans shall be suitable for operation on 415±10% volts, 50Hz, 3 phase AC
power supply. Axial flow fans shall be provided with inlet and outlet cones fabricated
at site using GS sheet having thickness not less than 20G and necessary vibration
isolation arrangement including spring type vibration isolators and rubber groumet etc.
as required. Fans shall be IP-55 rated. All fans should be AMCA certified. Motor shall
Fan Capacity S.P Motor Area being Fan
No. (Cfm) (mmWG) Rating/Class fed Dia/RPM
Class'H' Smoke Exhaust
Class'H' Smoke Exhaust
Class'H' Smoke Exhaust
(Basement to Terrace)
1.3 EXTRACT FAN SECTION- FLOOR MOUNTED
Supply, Installation, Testing & Commissioning of Extract Fan Sections (EFS)
comprising of following as per the specifications :
a. Casing of EFS shall be in double skin
construction. Inner skin shall be constructed out of 24 gauge plain GS sheet & outer
skin in 24 gauge pre-plasticized GS sheet sandwitched between 25mm thick
injected PU foam insulation of density not less than 40 Kg /CuM and complete with
inspection doors and marine light, limit switch including control wiring as required.
Fan section complete with backward curved DIDW type centrifugal fan/s, IE-2 type
TEFC squirrel cage induction motor suitable to operate on 415+10%V, 50Hz, 3
phase AC power supply and belt drive package. Fan outlet velocity shall not be
more than 2000 FPM (10.16 MPS)
In addition to the above, Extract Fan Section shall be provided with adequate vibration
isolation pads and fire retardent flexible canvass connections made out of canvass
sleeve. Sizes of Extract Fan Sections shall not exceed as mentioned in the design
drawings and EFS shall conform to the design parameters mentioned in
specifications. Fan should be suitable for outdoor application.
Floor Mounted type Extract Fan Section(EFS) as described above with following duty
M/c No Capacity S.P Motor Area to
(Cfm) (mmWG) Rating be fed
1.4 EXTRACT FAN SECTIONS - CEILING SUSPENDED
Supply, Installation, Testing & Commissioning of Extract Fan Sections (EFS)
comprising of following as per the specifications :
Casing of EFS shall be in double skin construction. Inner skin shall be
constructed out of 24 gauge plain GS sheet & outer skin in 24 gauge pre-plasticized
GS sheet sandwitched between 25mm thick injected PU foam insulation of density
not less than 40 Kg /CuM and complete with inspection doors and marine light, limit
switch including control wiring as required.
Fan section complete with forward curved DIDW type centrifugal fan/s, IE-2 type
TEFC squirrel cage induction motor suitable to operate on 415+10%V, 50Hz, 3
phase AC power supply and belt drive package. Fan outlet velocity shall not be
more than 1800 FPM (9.16 MPS)
In addition to the above, Extract Fan Section shall be complete with suspension
arrangement, it shall also include spring type vibration isolators and rubber groomets
etc. to make the installation totally vibration free and fire retardent flexible canvass
connections made out of canvass sleeve. Sizes of Extract Fan Sections shall not
exceed as mentioned in the design drawings and air handling units shall conform
to the design parameters mentioned in specifications.
Extract Fan Section(EFS) as described above with following duty parameters :
M/c No Capacity S.P Motor Area to
(Cfm) (mmWG) Rating be exhausted
c Fan-3 4000 22-25 2.0 Plumbing/ Fire Plant Room No 1.00 59100.72 0.00 59100.72
1.5 FRESH AIR FAN WITH MIXING CHAMBER (CEILING SUSPENDED)
Supply, Installation, Testing & Commissioning of Fan Filter Unit (FFU) comprising
of following as per the specifications :
ANUJ NAVNEET Digitally signed by ANUJ
CHACHA Date: 2023.01.10
BILL OF QUANTITY
Construction of Residential Accommodation for Faculty & Staff at Institute of Liver and Biliary Sciences (ILBS) at the risk and cost of previous agency
Code No. DESCRIPTION
SL.NO. UNIT QUANTITY DSR NDSR DSR NDSR
Casing of EFS shall be in double skin construction. Inner skin shall be
constructed out of 24 gauge plain GS sheet & outer skin in 24 gauge pre-plasticized
GS sheet sandwitched between 25mm thick injected PU foam insulation of density
not less than 40 Kg /CuM and complete with inspection doors and marine light, limit
switch including control wiring as required.
Fan section complete with forward curved DIDW type centrifugal fan/s, IE-2 type
TEFC squirrel cage induction motor suitable to operate on 415+10%V, 50Hz, 3
phase AC power supply and belt drive package. Fan outlet velocity shall not be
more than 1800 FPM (9.16 MPS), All fans should be AMCA certified.
FFUs shall be complete with Pre- Filter section complete with 50 mm thick washable
synthetic fiber filters. Velocity across the filters shall not exceed 500 FPM.
In addition to the above, Extract Fan Section shall be complete with suspension
arrangement, it shall also include spring type vibration isolators and rubber groomets
etc. to make the installation totally vibration free and fire retardent flexible canvass
connections made out of canvass sleeve. Sizes of Extract Fan Sections shall not
exceed as mentioned in the design drawings and air handling units shall conform
to the design parameters mentioned in specifications.
Fan Filter Unit Section(FFU) as described above with following
duty parameters :
M/c No Capacity S.P Motor Area to
(Cfm) (mmWG) Rating be exhausted
d Fan-4 4000 26-28 2.0 Plumbing/ Fire Plant Room No 1.00 74653.54 0.00 74653.54
1.6 PROPELLER FANS
Supply, Installation, Testing and Commissioning of propeller fans for exhaust air as
shown on drawings. Each fan shall be complete with class "F" insulated motor,
permanent split capacitor, mounting plate and accessories like wire guard, bird
screen and gravity louvers for weather protection as required. Fan selection,
arrangement and electrical characteristics shall be as follows :
All Fans shall be provided with speed regulators
Quoted price shall be inclusive of copper power cabling from fan to single phase
power point along with 3 pin plug.
a. 450 mm dia 900 RPM fan,single phase. No 1.00 6609.95 0.00 6609.95
b. 380 mm dia 900 RPM fan, single phase. No 1.00 6065.60 0.00 6065.60
TOTAL ITEM NO. 1 (EQUIPMENT) Rs. 0.00 2661321.00
2 DUCTWORK/AIR TERMINALS
2.1 FACTORY FABRICATED DUCTING
Supply , Installation and Testing of factory fabricated GSS ducting complete
with vanes, splitter dampers, fire retardant gaskets hanging arrangement including
fully threaded GI rods and GI "C" channels/MS angle/rolled steel wires or Gripple
449 MR Wire Rope Hangers & Supports complete with end fixing, GI "C" channels etc. as
approved by clients/consultants in accordance with the approved shop drawings and
specifications. channel in accordance with the approved shop drawings and
specifications.
Spacing between duct supports should not exceed 2m in both cases i.e GI rods with
GI "C" channels & Gripple Wire Rope Hanger support . In case of Gripple Wire Rope
Hanger support for duct sizes above 1800mm, MS angles duly painted with black
enamel paint should be used along with neoprene pad in between the duct & MS
While selecting the duct supports vendor shall ensure vibration free installation.
Quoted price shall be inclusive of smoke test using smoke bombs.
a. 1mm to 899mm -- 24G GSS with TDC Joints SqM 680.00 902.06 0.00 613400.80
b. 900mm to 1500mm -- 22G GSS with TDC Joints SqM 1280.00 1014.82 0.00 1298969.60
c. 1501mm to 2100mm - 20G GSS with TDC Joints SqM 350.00 1158.69 0.00 405541.50
d. 2101mm to 2700mm - 18G GSS with TDC Joints SqM 100.00 1259.78 0.00 125978.00
2.2 SITE FABRICATED DUCTING
Supply, Fabrication, Installation and Testing of sheet metal ducts complete with
450 MR vanes, splitter dampers, hanging arrangement including check nuts in
accordance with the approved shop drawings and specifications
Supply, Installation , Testing of 125mm deep antivibration flexible joints at the outlet
of centrifugal/ inline fans. Flexible connections shall be constructed from imported
fire retardant fabric with extruded aluminium frame/flange on both sides of approved
Supply, Installation ,Testing and Balancing of double louvered supply air grilles as
452 2.4 per approved shop drawings and specifications complete with key operated
aluminium volume control dampers.
a. Powder coated extruded aluminium grilles. SqM 0.50 9020.64 0.00 4510.32
ANUJ NAVNEET Digitally signed by ANUJ
CHACHA Date: 2023.01.10
BILL OF QUANTITY
Construction of Residential Accommodation for Faculty & Staff at Institute of Liver and Biliary Sciences (ILBS) at the risk and cost of previous agency
Code No. DESCRIPTION
SL.NO. UNIT QUANTITY DSR NDSR DSR NDSR
Supply, Installation ,Testing and Balancing of one way blow linear exhaust air grilles
453 2.5 as per approved shop drawings and specifications.The grilles shall be of approved
colour & shade.
a. Powder coated aluminium grille of extruded sections with integral flanges on both
sides & ends as required .
Supply, Installation and Testing of Aluminium multi blade type louver dampers as per
the specifications and shop drawings of approved colour & shade.
Supply, Installation and Testing of extruded aluminium powder coated air transfer
grilles to be provided at the door of service & storage areas.
Supply, Installation and Testing of GI box type volume control dampers as per
the specifications and shop drawings.
Supply, Installation and Testing of fresh air grilles of powder coated / anodised
457 2.9 extruded aluminium with GI wire mesh, inlet louvers, dampers & bird screen, as SqM 0.50 5754.54 0.00 2877.27
per the approved shop drawings and specifications.
Supply, Installation and Testing of extruded aluminium powder coated louver with
GI wire mesh to be installed outside for discharge of exhaust air from exhaust fans
458 2.1 as per the specifications and shop drawings. Sample of louvers to be got approved SqM 2.00 6532.19 0.00 13064.38
from consultants and Clients prior to procurement.
Supply, Installation and Testing of Bird Screens with GI wire mesh to be installed at
the suction/dischagre of axial fans or discharge of exhaust air from exhaust fans as
459 2.11 per the specifications and shop drawings. Sample of bird screen to be got approved SqM 12.00 4199.26 0.00 50391.12
from consultants and Clients prior to procurement.
Supply, Installation and Testing of non return dampers. NRDs to be installed in the
ducts as per the specifications and shop drawings. Sample of NRDs to be got
approved from consultants and Clients prior to procurement.
Supply, Installation and Testing of multiblade box type zero leakage extruded
aluminium dampers for ducts to be provided with suitable links, levers and
461 2.14 quadrants for manual control of volume of air flow and for proper balancing of the SqM 0.50 8865.11 0.00 4432.56
air distribution system as per the approved shop drawing and specifications.
Supply and fixing of actuators of suitable rating of torque complete with copper wiring
462 2.15 from the junction box and actuator associated with the above VCDs.
Actuator shall be suitable for duct size as shown in the drawing. No 1.00 10031.57 0.00 10031.57
2.16 ACOUSTIC LINING OF WALLS - Fan Rooms
Supply and Application of acoustic/ thermal lining of walls of Fan rooms using resin
bonded fibre glass insulation of density not less than 32Kg/CuM as per the approved
463 shop drawings and specifications. Quoted price shall be inclusive of GSS channel,
metal screws, washers, fibre glass tissue, perforated sheet etc. as required for
complete installation.
a. 50mm thick lining SqM 5.00 789.31 0.00 3946.55
TOTAL ITEM NO. 2 Rs. 0.00 3364966.65
3.0 ELECTRICAL WORKS
Supply,Installation,Testing and Commissioning of the following cubical type panels
made out of 14 guage CRCA structure, base channel, complete with, moulded case
circuit breakers, meters, indicating lamps, current transformer etc. Complete in all
respects, insulated bus bars with heat shrinkable PVC sleeve in suitable bus
chambers, interconnection, small wiring, name plate, danger plate, earth bus etc. &
464 MR comprising of compartments with hinged door for each feeder & its accessories,
cable alley with hinged doors, bus chamber with bolted door etc. The panel being of
dust & vermin proof construction with rubber gasket attractively powder coating
etc. The panel shall be free standing type / wall mounted type as per relavant
drawing and comprising with the following:
1. All MCCBs shall be with operating handle.
2. CTs burden shall be 15VA & accuracy class 1.0
3. CTs shall be cast resin type .
4. All MCCBs shall be with thermal magnetic release.
5. All indication lights shall be LED type.
6. All meter shall be digital type.
7. The outgoing starter feeders for pumps, AHUS & ventilation fans shall be
provided with push buttons & indicating lamps for status indication.
8. Proper isolation switches to be provided near air handling units and
ventilation fans in weather proof enclosure. phasing prevention feature.
9. Bimetal overload relay for all the starters shall have built-in single
10. Electrical interlocking wiring shall be provided as per system requirement.
11. Power cabling/wiring with necessary earthing from source to each panel
and each exhaust fan shall be provided by other agencies.
ANUJ NAVNEET Digitally signed by ANUJ
CHACHA Date: 2023.01.10
BILL OF QUANTITY
Construction of Residential Accommodation for Faculty & Staff at Institute of Liver and Biliary Sciences (ILBS) at the risk and cost of previous agency
Code No. DESCRIPTION
SL.NO. UNIT QUANTITY DSR NDSR DSR NDSR
12. All Panels to be provided with Potential free contacts and integration arrangement
required to integrate with Fire Alarm System.
13. All Panels shall be BMS compatible.
For Car Parking Ventilation System
a 3.1.1 MVS PANEL -For Normal/Smoke For Vane/Tube Axial Fans-11KW No 6.00 41992.62 0.00 251955.72
63 Amps ,TP MCCB -- 1set
(0-500) V digital Voltmeter with built in Selector
Digital Ammeter with built in selector
Current Transformers - 1set
LED type RYB phase indication lights- 1set
LED type ON & OFF indication lights- 1set
START-STOP Push Buttons -- 1 set
A/M selector switch -- 1 set
15.0HP Star Delta starter with built-in single phasing preventor & overload relay &
adjustable timer-- 1 set
Contactors, Potential Free Contacts, Control wiring and safety circuit as required with
start-stop push buttons stay put or lockable type -1 set.
b 3.1.2 MVS PANEL -For Normal/Smoke No 2.00 35382.67 0.00 70765.34
For Vane/Tube Axial Fans-7.5KW
40 Amps ,TP MCCB -- 1set
(0-500) V digital Voltmeter with built in Selector switch -- 1set
Digital Ammeter with built in selector switch- 1set
Current Transformers - 1set
LED type RYB phase indication lights- 1set
LED type ON & OFF indication lights- 1set
START-STOP Push Buttons -- 1 set
A/M selector switch -- 1 set
10.0HP Star Delta starter with built-in single phasing preventor & overload relay &
adjustable timer-- 1 set
Contactors, Potential Free Contacts, Control wiring and safety circuit as required with
start-stop push buttons stay put or lockable type -1 set.
For Pressurization System
c 3.1.3 PRESSURIZATION PANEL No 8.00 30328.00 0.00 242624.00
(Location : Terrace )
For 13500Cfm Capacity Axial Fans for Liftwells - 5.5KW each
32 Amps ,TP MCCB -- 1set
(0-500) V digital Voltmeter with built in Selector switch -- 1set
Digital Ammeter with built in selector switch- 1set
Current Transformers - 1set
LED type RYB phase indication lights- 1set
LED type ON & OFF indication lights- 1set
START-STOP Push Buttons -- 1 set
A/M selector switch -- 1 set
7.5HP DOL starter with built-in single phasing preventor & overload relay &
adjustable timer-- 1 set
Contactors, Potential Free Contacts, Control wiring and safety circuit as required with
start-stop push buttons stay put or lockable type -1 set.
(Location : Terrace )
For 5500Cfm Capacity Extract Fan Section - 3.7KW
32 Amps ,TP MCCB -- 1set
(0-500) V digital Voltmeter with built in Selector switch -- 1set
Digital Ammeter with built in selector switch- 1set
Current Transformers - 1set
LED type RYB phase indication lights- 1set
LED type ON & OFF indication lights- 1set
START-STOP Push Buttons -- 1 set
A/M selector switch -- 1 set
5.0HP DOL starter with built-in single phasing preventor & overload relay &
adjustable timer-- 1 set
Contactors, Potential Free Contacts, Control wiring and safety circuit as required with
start-stop push buttons stay put or lockable type -1 set.
e 3.1.5 EFP/FFP-1 (Location: Near EFS)
For Various capacity EFS/FFU - 1.1KW/0.75KW No 4.00 22551.59 0.00 90206.36
20 Amps ,TP MCCB -- 1set
(0-500) V digital Voltmeter with built in Selector switch -- 1set
Digital Ammeter with built in selector switch- 1set
Current Transformers - 1set
LED type RYB phase indication lights- 1set
LED type ON & OFF indication lights- 1set
START-STOP Push Buttons -- 1 set
1/1.5HP DOL starter with built-in single phasing
preventor & overload relay -- 1set
Auto-Manual type selector switch to facilitate auto start of AHUs -- 1set
Contactors, Potential Free Contacts, Control wiring and safety circuit as required with
start-stop push buttons stay put or lockable type -1 set.
For 4000Cfm capacity FFU - 2.2KW/1.5KW
25 Amps ,TP MCCB -- 1set
(0-500) V digital Voltmeter with built in Selector switch -- 1set
Digital Ammeter with built in selector switch- 1set
Current Transformers - 1set
LED type RYB phase indication lights- 1set
LED type ON & OFF indication lights- 1set
ANUJ NAVNEET Digitally signed by ANUJ
CHACHA Date: 2023.01.10
BILL OF QUANTITY
Construction of Residential Accommodation for Faculty & Staff at Institute of Liver and Biliary Sciences (ILBS) at the risk and cost of previous agency
Code No. DESCRIPTION
SL.NO. UNIT QUANTITY DSR NDSR DSR NDSR
START-STOP Push Buttons -- 1 set
3/2HP DOL starter with built-in single phasing
preventor & overload relay -- 1set
Auto-Manual type selector switch to facilitate auto start of AHUs -- 1set
Contactors, Potential Free Contacts, Control wiring and safety circuit as required with
start-stop push buttons stay put or lockable type -1 set.
Supply, laying, affecting connections and Testing of the following sizes of
1.1 KV armoured PVC insulated aluminium/ copper conductor cables. Cables
shall be inclusive of all clamps, saddles, screws, cable identification tags, cable
terminal joints including terminal lugs, insulating tapes, affecting terminal
465 3.2.1 connections to the equipment as per the specifications and as required. Quoted
price shall be inclusive of perforated duly painted 2mm thick MS trays to be installed
inside and GI trays to be installed outside exposed and 8SWG copper earth wire for
all equipment. All power cables shall be FRLS type.
d. d. 3 C x 4 Sqmm cable (Copper) RM 90.00 349.94 0.00 31494.60
f. f. 3 C x 2.5 Sqmm cable( Copper Control cabling) RM 110.00 295.50 0.00 32505.00
g. g. 3 C x 1.5 Sqmm cable(Copper Control cabling) RM 250.00 163.30 0.00 40825.00
h. h. 4 C x 1.5 Sqmm cable( Copper Control cabling) RM 20.00 194.41 0.00 3888.20
Supply and fixing of 1.1 KV grade rubber mat 914.4 mm wide 6mm thick to
withstand 1.1 KV dielectric strength in front of each panel.
Supply, Installation & Testing of TPN isolator in weather proof enclosure near
TOTAL ITEM NO. 3 (ELECTRICAL) Rs. 0.00 1430470.68
PIPING FOR PROVISIONAL SPLIT AC IN FLATS
1.1 REFRIGERANT PIPING
Make - Rajco/Mandev /Jindal
Supply, Installation,Testing & Commissioning of copper refrigerant piping complete
with copper fittings & charge of regrigerant gas for the above split units. Piping
associated with split units to be insulated with 16mm thick closed cell elastomeric
insulation with Class 'O' in tubing form as required. Piping shall be laid over duly
painted slotted angle trays fixed with GI clamps. Quoted Price shall be inclusive of
UV protection paint for all exposed pipes of approved make. Referigerant piping shall
be epoxy coated to prevent erosion.
Price shall be inclusive of copper power & control cabling from indoor to
outdoor unit as required
Piping should be suitable for R-32/R410A/R407C Refrigerant.
Pair of Soft refrigerant piping for non ductable split units with rotary compressor.
1.2 CONDENSATE DRAIN PIPING-GI
Make - Tata Steel/ Jindal (Hissar)
Supply, Installation , Testing and Commissioning of GI medium class (Class 'B')
pipes cut to requird lengths and installed with all screwed joints for condensate
drain. Quoted price shall be inclusive of supply and fixing in position the necessary
fittings like elbows, tees reducers etc. and supporting arrangement in accordance
with the approved shop drawings and specifications. Pipes shall be insulated with
9mm thick closed cell elastomeric insulation with class 'O' fire retardant properties in
tubing form . Pipes shall be of following sizes :
1.3 CONDENSATE DRAIN PIPING -cPVC
Make - Poly Pack/Astral/Supreme
Supply, Installation, Testing and Commissioning of cPVC pipes cut to required
lengths and installed for condensate drain. Quoted price shall be inclusive of supply
and fixing in position the necessary fittings like elbows, tees reducers etc. and
470 supporting arrangement in accordance with the approved shop drawings and
specifications. Pipes shall be insulated with 9mm thick closed cell elastomeric
insulation with class 'O' fire retardant properties in tubing form . Pipes shall be of
following sizes :
TOTAL ITEM NO. 1 (PIPING) Rs. 10552308.82
1.00 SUB HEAD I - HORTICULTURE
1.1 LAND PREPARATION
ANUJ NAVNEET Digitally signed by ANUJ
CHACHA Date: 2023.01.10
BILL OF QUANTITY
Construction of Residential Accommodation for Faculty & Staff at Institute of Liver and Biliary Sciences (ILBS) at the risk and cost of previous agency
Code No. DESCRIPTION
SL.NO. UNIT QUANTITY DSR NDSR DSR NDSR
Providing and laying grass pavers of size 300mm x 300mm and thickness of 60 mm
should be prefab factory made cement concrete interlocking grass pavers of M-30
mix, suitably reinforced and manufactured in joint less moulds on vibrator table
finished smooth as per required shape size and pattern and colour. To be laid over
50mm thk. sandbed on top of consolidated earth after proper levelling and dressing of
ground surface to the requisite slopes complete in all respects as per directions and
instructions of Engineer in charge.
Preparation of beds for hedging and shrubbery by excavating 60 cm deep and
trenching the excavated base to a further depth of 30 cm, refilling the excavated earth
after breaking clods and mixing with sludge or manure in the ratio of 8:1 (8 parts of
stacked volume of earth after reduction by 20% : one part of stacked volume of sludge
472 or manure after reduction by 8%), flooding with water, filling with earth if necessary, Cum 500.00 101.09 50545.00
watering and finally fine dressing, leveling etc. including stacking and disposal of
materials declared unserviceable and surplus earth by spreading and leveling as
directed, within a lead of 50 m, lift up to 1.5 m complete (cost of sludge, manure or
extra earth to be paid for separately)
Digging holes in ordinary soil and refilling the same with the excavated earth mixed
with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth
after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%)
flooding with water, dressing including removal of rubbish and surplus earth, if any,
with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid
for separately) :
a Holes .90 cm dia, and .90 cm deep Each 630.00 85.54 53890.20
b Holes 0.60 m dia and .60 m deep Each 123.00 27.22 3348.06
Supplying and stacking of good earth at site including royalty and carriage upto 5 km
complete (earth measured in stacks will be reduced by 20% for payment)
Supplying and stacking at site dump manure from approved source, including
475 carriage upto 5 km complete (manure measured in stacks will be reduced by 8% for Cum. 250.00 699.88 174970.00
Mixing earth and sludge or manure in the required proportion specified or directed by
the Officer-in-charge
Filling mixture of earth and sludge or manure in the desired proportion in trenches,
477 flooding with water and leveling (cost of supplying earth and sludge or manure and Cum. 500.00 42.77 21385.00
mixing excluded).
478 1.2 TREES & PALMS
Providing and planting of sita Saraca Asoca(Ashoka) of ht. 8-9 ft well developed in big
size HDPE bags as per direction of the officer-in-charge.
Providing and planting of Plumeria Alba (Champa) of ht. 6 - 8ft well developed in big
size HDPE bags as per direction of the officer-in-charge.
Providing and planting of Plumeria Alba (Champa) of ht. 6 - 8ft well developed in big
size HDPE bags as per direction of the officer-in-charge.
Providing and planting of Neolamarckia Cadamba (Kadamba) tree of ht. 9ft well
developed in big size HDPE bags as per direction of the officer-in-charge.
Providing and planting Nycanthes Arbor (Harsingar) of ht. 8 - 9 ft. well developed in
big size HDPE bags as per direction of the officer-in-charge.
Providing and planting Bahunia Blakeana (Kachnar)of ht. 8 - 9 ft. well developed in big
size HDPE bags as per direction of the officer-in-charge.
Providing and planting Cassia Fitsula (Amaltas) of ht. 8 - 9 ft. well developed in big
size HDPE bags as per direction of the officer-in-charge.
Providing and planting Cassia Fitsula (Amaltas) of ht. 8 - 9 ft. well developed in big
size HDPE bags as per direction of the officer-in-charge.
Providing and planting Jacaranda Mimosofolia (Jacaranda) of ht. 8 - 9 ft. well
developed in big size HDPE bags as per direction of the officer-in-charge.
Providing and planting Dalbergia Sisso (Sheesham)of ht. 8 - 9 ft. well developed in
big size HDPE bags as per direction of the officer-in-charge.
Providing and planting Callistemon (Bottle Brush) of ht. 8 - 9 ft. well developed in big
size HDPE bags as per direction of the officer-in-charge.
Providing and planting Azadirachta Indica (Neem) of ht. 8 - 9 ft. well developed in big
size HDPE bags as per direction of the officer-in-charge.
Providing and planting Ceiba Speciosa (Floss Silk Tree)of ht. 8 - 9 ft. well developed
in big size HDPE bags as per direction of the officer-in-charge.
Providing and planting Bambusa Vulgaris (Bamboo) of ht. 6-7 ft. ft. well developed in
big size HDPE bags as per direction of the officer-in-charge.
Providing and planting Date palm of ht. 4 ft. ft. well developed in big size HDPE bags
as per direction of the officer-in-charge.
Providing and planting TerminaliaArjuna (Arjun tree) of ht. 5 ft. ft. well developed in
big size HDPE bags as per direction of the officer-in-charge.
Providing and planting Bombaxciba(Simul) of ht. 6 ft. ft. well developed in big size
HDPE bags as per direction of the officer-in-charge.
Providing and planting Butea Monosperma(Palash) of ht. 7 ft. ft. well developed in big
size HDPE bags as per direction of the officer-in-charge.
Providing and planting Erythrina Variegata(Indian Coral Plant) of ht. 8 ft. ft. well
developed in big size HDPE bags as per direction of the officer-in-charge.
Providing and planting Dypsis Lutescens(Areca Palam) of ht. 9 ft. ft. well developed in
big size HDPE bags as per direction of the officer-in-charge.
Providing and planting Roystonea Regia(Royal Palm) of ht. 10 ft. ft. well developed in
big size HDPE bags as per direction of the officer-in-charge.
Providing and planting Cycus Revoluta(Cycus Palm) of ht. 3ft. well developed in big
size HDPE bags as per direction of the officer-in-charge.
Providing and planting Washingtonia Robusta(Washingtonia Palm) of ht. 8ft. well
developed in big size HDPE bags as per direction of the officer-in-charge.
Providing and planting Raphies Excelsa (Raphies Palm) of ht. 3ft. well developed in
big size HDPE bags as per direction of the officer-in-charge.
479 1.3 SPECIAL TREES
ANUJ NAVNEET Digitally signed by ANUJ
CHACHA Date: 2023.01.10
BILL OF QUANTITY
Construction of Residential Accommodation for Faculty & Staff at Institute of Liver and Biliary Sciences (ILBS) at the risk and cost of previous agency
Code No. DESCRIPTION
SL.NO. UNIT QUANTITY DSR NDSR DSR NDSR
Providing and planting Manilkara Zapota (chikoo) of ht. 6-9 ft. well developed in big
size HDPE bags as per direction of the officer-in-charge.
Providing and planting Morus Alba(Shahtoot Tree) of ht. 6 ft. well developed in big
size HDPE bags as per direction of the officer-in-charge.
Providing and planting Mangifera Indica (Amrapali Tree) of ht. 5 ft. well developed in
big size HDPE bags as per direction of the officer-in-charge.
Providing and planting Syzygium Cumini L (JamunTree) of ht. 6 ft. well developed in
big size HDPE bags as per direction of the officer-in-charge.
Providing and planting of Psidium Guava of ht. 6 - 8ft well developed in big size
HDPE bags as per direction of the officer-in-charge.
480 1.3 HERBAL PLANTS
Providing and planting of Euphobia Nerifolia (Sehund) of ht. 2-4ft well developed in
big size HDPE bags as per direction of the officer-in-charge.
Providing and planting of Aloe Barbadensis Miller (Aloe Vera) of ht. 1ft well
developed in 40 cm challi, as per direction of the officer-in-charge.
Providing and planting of Ocimum Tenuifloum (Tulsi) of ht. 1ft well developed in 40
cm challi, as per direction of the officer-in-charge.
Providing and planting of Withana Somnifera(Ashwagandha) of ht. 1ft. well
developed in big size HDPE bags as per direction of the officer-in-charge.
Providing and planting of Stevia Rebaudiana(Stevia) of ht. 1-2 ft. well developed in
big size HDPE bags as per direction of the officer-in-charge.
Providing and planting of Tinospora Cordifolia(Giloy) of ht. 1-2 ft. well developed in 40
cm challi, as per direction of the officer-in-charge.
Providing and planting of Asparagus Racemosus(Shatavri) of ht. 1-2 ft. well
developed in big size HDPE bags as per direction of the officer-in-charge.
Providing and planting of Murraya Koenigii(Sweet Neem) of ht. 2-3 ft. well developed
in big size HDPE bags as per direction of the officer-in-charge.
Providing and planting of Lemon grass of ht. 1 ft. well developed in big size HDPE
bags as per direction of the officer-in-charge.
Providing and planting of Moringa of ht. 4 ft. well developed in big size HDPE bags
as per direction of the officer-in-charge.
481 1.4 SHRUBS,HEDGES CLIMBERS/SPECIMEN PLANTS
a Hymenocallis (Spider Lillies) Each 17 69.99 1189.83
b Cleodendurm (Enermi Hedge) Each 800 19.44 15552.00
c Hibiscus (China Rose) Each 100 46.66 4666.00
d Red Acalphya (Chenile Plant) Each 100 57.55 5755.00
e Ficus Starlight Each 50 174.97 8748.50
f Dracaena Reflexa (Song Of India) Each 100 174.97 17497.00
g Sygonium Podophyllum Each 200 97.21 19442.00
h Nerium Oleander Each 50 58.32 2916.00
i Cestrum Nocturnum Each 50 46.66 2333.00
j Hamelia (Firebush) Each 200 46.66 9332.00
k Canna Indica (Canna) Each 50 58.32 2916.00
l Ixora Coccinea Each 100 97.21 9721.00
m Euphobia (White Kaner) Each 50 85.54 4277.00
n Tabarnaemona Coronaria Each 100 58.32 5832.00
o fIcus Benjamina (Black Fecus) Each 50 427.70 21385.00
p Ficus Panda Each 50 174.97 8748.50
r Iresine Herbstii 1000 34.99 34990.00
t Fountain Grass 1000 34.99 34990.00
482 1.5 GROUND COVER
Supplying & planting of Selection No.1 Grass at site fresh & free from weeds having
b proper roots in green including loading, unloading, carriage and all taxes paid etc.and Sqm 500.00 85.54 42770.00
as per direction of officer in charge (CARPET FORM)
Total TOTAL 0.00 2127447.05
Earth work in excavation by mechanical means (Hydraulic excavator)/manual
means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10
sqm on plan) including getting out and disposal of excavated earth lead
upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.
2.6.1 In all type of soil cum 4569 141.41 646102.29 0
Providing and laying in position cement concrete of specified grade excluding the cost
of centering and shuttering
4.1.8 1:4:8 (1 Cement :4 coarse sand : 8 stone aggregate 40 mm ) cum 370 4502.23 1665825.1 0
Providing and laying flamed finish Granite stone flooring in required design and
patterns, in linear as well as curvilinear portions of the building, all complete as per
the architectural drawings, with 18 mm thick stone slab over 20 mm (average) thick
base of cement mortar 1:4 (1 cement : 4 coarse sand), laid and jointed with cement
slurry and pointing with white cement slurry admixed with pigment of matching shade,
including rubbing, curing and polishing etc. all complete as specified and as directed
by the Engineer-in-Charge.
Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or
Providing & fixing 100mmx100mm, 60mm thk natural finish Grey coloured cobbles
ANUJ NAVNEET Digitally signed by ANUJ
CHACHA Date: 2023.01.10
BILL OF QUANTITY
Construction of Residential Accommodation for Faculty & Staff at Institute of Liver and Biliary Sciences (ILBS) at the risk and cost of previous agency
Code No. DESCRIPTION
SL.NO. UNIT QUANTITY DSR NDSR DSR NDSR
Providing and laying faciory made chamfered edge cement concrete paver block in
footpath, parks, lawns, drive ways or light traffic parking etc. of required strength,
thickness & size/ shape, made by table vibratory method using PU Mould, laid in
required colour and pattern over 50mm thick compacted bed of sand, compacting and
c 16.91 proper embedding/ laying of interlocking paver blocks into the sand bedding layer
through vibradory compaction using by using plate vibrator, filling the joints with sand
and cutting of paver blocks as per reqired size and pattern, finishing and sweeping
extra sand complete all as per direction of Engineer-in-charge.
60mm thick cement concrete paver block of M-35 grade with approved colour, design
Providing, laying and making kerb channel 30 cm wide and 50 mm
thick with cement concrete 1:3:6 (1 cement: 3 coarse sand:6 graded
stone aggregate 20 mm nominal size) over 75mm bed of dry brick
ballast 40 mm nominal size, well rammed and consolidated
and grouted with fine sand, including finishing the top smooth etc.
complete and as per direction of Engineer-in-charge.
Mint Sand Stone work, plain in copings, cornices, string courses and plinth courses,
upto 75 mm thick in Cement mortar 1:6 (1 cement : 6 coarse sand), including pointing
with white cement mortar 1:2 (1 white cement : 3 stone dust) with an admixture of
pigment matching the stone shade.
TERRAZO FLOORING 40 mm thick marble chips flooring rubbed and polished to
finish, under layer 34 mm thick cement concrete 1:2:4 (1 cement : 2
coarse sand : 4 graded stone aggregate 12.5 mm nominal size) and top
f 11.9 layer 6mm thick with white, black, chocolate, grey, yellow or green marble chips of
sizes from 1 mm to 4 mm nominal size, laid in cement
marble powder mix 3:1 (3 cement : 1 marble powder) by weight in
proportion of 4:7 (4 cement marble powder mix : 7 marble chips) by
volume, including cement slurry etc. complete
11.9.5 Light shade pigment with ordinary cement sqm 130.00 655.71 85242.3 0
Providing and laying 5mm thk EPDM flooring, colour as/selection to be laid over the
hard concrete surface
3.0 LANDSCAPE LIGHTING
spike / surface mounted tree up lighter made of pressure die cast aluminium
Light Source : 3w Led
Dimension : Dia - 90mm Length - 100mm
487 MR POST TOP LIGHT
Decorative Post top light complete with 20W LED DECORATIVE MS Pole
TopDia:75mm, with 60 mm nipple
Top height : 2000mm
Thickness:3mm . Height:2000mm
Bottom dia;114mm thikness;4.2 mm
Botom Height:1000mm. with alluminium amblishment. with inside junction box
Mounting base plate 250 mm dia10mm
Approx 40 kg pole
PU Painted in any colour( p.uMRF) painted as per client req.)
488 MR CONCEALED WALL LIGHTS
Light Source : 5w NOS 40 116.65 0 4666
489 MR UPDOWN LIGHT
490 MR DOWN LIGHTERS
Light Source : 3w NOS 25 342.16 0 8554
4.0 PLAY EQUIPMENTS
491 MR Supply and installation of Wave Slide -PH : 5 FT / LENGTH : 10 FT NOS 1 33049.75 0 33049.75
492 MR Supply and installation of Double Swing -10 X 5 X 10 FEET NOS 1 31105.64 0 31105.64
493 MR Supply and installation of Platform Merry Go Round - DAI : 5 FEET NOS 1 38493.23 0 38493.23
494 MR Supply and installation of Two Seater See Saw NOS 1 15552.82 0 15552.82
Single play station - complete with all ropes swings and slides.Design to be approved
5.0 BADMINTON FACILITY
Supply & fixing of one pair of Badminton poles along with net. All poles as per
international standard. Structure made of MS ISI mark tubing outer pole outer dia
88mm.Painting of lines by polyurethan paint or equivalant to demarkat the court.
6.0 BASKETBALL FACILITY
Construction of the base and Providing and Laying of Synthetic Basketball Layer
European Acrylic System on Asphalt Surface which consists of One Layer of
Resurfacer, two layer of Coarse cushion, two layer of fine cushion two layer of pre
color coat and followed by UV Protected top coat and line marking as per track
requirements. Consumption ratios of all components of the proposed system to be as
per manufacturer instructions.
8.0 WATER FOUNTAIN
499 Water Fountain
a MR Jet Nozzle Nos 3 4424.78 0 13274.34
ANUJ NAVNEET Digitally signed by ANUJ
CHACHA Date: 2023.01.10
BILL OF QUANTITY
Construction of Residential Accommodation for Faculty & Staff at Institute of Liver and Biliary Sciences (ILBS) at the risk and cost of previous agency
Code No. DESCRIPTION
SL.NO. UNIT QUANTITY DSR NDSR DSR NDSR
b MR Mushroom Nozzle Nos 3 3981.52 0 11944.56
c MR Angular Valve Nos 6 1629.16 0 9774.96
d MR Necessary Plumbing work Job 1 33570.77 0 33570.77
e MR Electrical Panel 5HP Nos 1 12543.35 0 12543.35
f MR Submersible Mono block Pump 5 HP Nos 1 28772.72 0 28772.72
g MR Installation, Testing & Commissioning Job 1 17582.46 0 17582.46
h MR LED Based Colour Changing Light Nos 6 7224.29 0 43345.74
i MR Necessary Electric Work Job 1 9059.52 0 9059.52
j MR Micro processing Controller Nos 1 21322.92 0 21322.92
k MR Power Supply Nos 1 7387.59 0 7387.59
Sub total of water body 1
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means
over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan)
including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5
m, as directed by Engineer-in-charge.
2.6.1 In all type of soil cum 3.71 141.41 524.6311 0
Providing and laying in position cement concrete of specified grade excluding the cost
501 of centring and shuttering - All work upto plinth
1:4:8 (1 Cement : 4 fine/ coarse sand : 8 graded stone aggregate 40 mm nominal
size). cum 0.92
Dry stone pitching 22.5 cm thick including supply of stones and preparing surface
complete cum 1.39
Brick work with common burnt clay selected F.P.S. (non modular) bricks
of class designation 7.5 in exposed brick work including making
horizontal and vertical grooves 10 mm wide 12 mm deep complete in
cement mortar 1:6 (1 cement : 6 coarse sand) cum 1.43
Providing and laying flamed finish Granite stone flooring in required design and
patterns, in linear as well as curvilinear portions of the building, all complete as per
the architectural drawings, with 18 mm thick stone slab over 20 mm (average) thick
base of cement mortar 1:4 (1 cement : 4 coarse sand), laid and jointed with cement
slurry and pointing with white cement slurry admixed with pigment of matching shade,
including rubbing, curing and polishing etc. all complete as specified and as directed
by the Engineer-in-Charge.
Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or
equivalent. sqm 8.58
ANUJ NAVNEET Digitally signed by ANUJ
CHACHA Date: 2023.01.10
Construction of Residential Accommodation for Faculty & Staff at Institute of Liver and Biliary Sciences (ILBS) at the risk and
cost of previous agency
SL.NO. DESCRIPTION UNIT QUANTIT RATE AMOUNT
Annual Maintenance Contract after expiry of 24 Months
Free Maintenance
Quote for Comprehensive Annual Maintenance Contract
(AMC) for each lift for 5 years beyond 2 year of guarantee
(i) 13 Passenger (1020Kg) For Highrise Towers (Refer
(ii) 8 Passenger (544Kg) For Highrise Towers (Refer
(i) 13 Passenger (1020Kg) For Highrise Towers (Refer
(ii) 8 Passenger (544Kg) For Highrise Towers (Refer
(i) 13 Passenger (1020Kg) For Highrise Towers (Refer
(ii) 8 Passenger (544Kg) For Highrise Towers (Refer
(i) 13 Passenger (1020Kg) For Highrise Towers (Refer
(ii) 8 Passenger (544Kg) For Highrise Towers (Refer
(i) 13 Passenger (1020Kg) For Highrise Towers (Refer
(ii) 8 Passenger (544Kg) For Highrise Towers (Refer
Operation and Maintenance of the Sewage Treatment
Plant (after three months of operation and maintenance
as mandated in the Scope of Work) for (2+5) years as
per the scope given below:
First 2 years after three months of operation and
maintenance as mandated in the Scope of Work
a) Operation of the plant to produce the required quantity
of treated effluent of quality as mentioned in the Scope of
Work of the Supply, Installation, Testing and
Commissioning of Sewage Treatment Plant mentioned
elsewhere in this document.
b) Operation includes 24 hours/day manned supervision
ANUJ NAVNEET Digitally signed by ANUJ
CHACHA Date: 2023.01.10
Construction of Residential Accommodation for Faculty & Staff at Institute of Liver and Biliary Sciences (ILBS) at the risk and
cost of previous agency
SL.NO. DESCRIPTION UNIT QUANTIT RATE AMOUNT
c) Supply of all consumables like enzymes, bio-mass and
d) General house keeping of the STP area
e) Removal and Carrage of sludge, dead plants, debris
etc. from the site.
f) Supply of skilled, semiskilled and unskilled labour for
the above. (one operator each shift x 3 shifts with
g) Monitoring the treated effluent quality and getting the
treated effluent sample tested atleast once in three
months from a lab acceptable to the Employer.
Employer`s Scope
a) Electricity would be provided free of cost
i) First Year (starting after three months of operation and
maintenance as mandated in the Scope of Work) Annum 1 777641.07 777641.07
ii) Second Year Annum 1 816523.13 816523.13
a) Operation of the plant to produce the required quantity
of treated effluent of quality as mentioned in the Scope of
Work of the Supply, Installation, Testing and
Commissioning of Sewage Treatment Plant mentioned
elsewhere in this document.
b) Operation includes 24 hours/day manned supervision
c) Supply of all consumables like enzymes, bio-mass and
d) Maintenance of all electrical and mechanical
equipment including supply of spares, consumables etc.
e) General house keeping of the STP area
f) Removal and Carrage of sludge, dead plants, debris
etc. from the site.
g) Supply of skilled, semiskilled and unskilled labour for
the above. (one operator each shift x 3 shifts with
h) Monitoring the treated effluent quality and getting the
treated effluent sample tested atleast once in three
months from a lab acceptable to the Employer.
Employer`s Scope
a) Electricity would be provided free of cost
i) First Year (starting after completion of operation and
maintenance as mentioned above under item No. 2 A) Annum 1 1166461.6 1166461.61
ii) Second Year Annum 1 1224784.7 1224784.69
iii) Third Year Annum 1 1286023.9 1286023.92
iv) Fourth Year Annum 1 1350373.7 1350373.72
v) Fifth Year Annum 1 1418028.5 1418028.49
ANUJ NAVNEET Digitally signed by ANUJ
CHACHA Date: 2023.01.10
Construction of Residential Accommodation for Faculty & Staff at Institute of Liver and Biliary Sciences (ILBS) at the risk and
cost of previous agency
SL.NO. DESCRIPTION UNIT QUANTIT RATE AMOUNT