Loading…
Loading…
| # | Company | Amount | Status |
|---|---|---|---|
| 1 | ₹64.7 LAdmitted-Finance LG 44 PLOT NO GH 01 NOIDA GREATER NOIDA LINK ROAD SECTOR 4 GREATER NOIDA GAUTAM BUDDHA NAGAR UTTAR PRADESH 201310 | GAUTAM BUDDHA NAGAR | UTTAR PRADESH | 201310 | ₹64.7 L | Admitted-Finance |
| 2 | ₹64.9 LAdmitted-Finance | ₹64.9 L | Admitted-Finance |
| 3 | ₹85.0 LAdmitted-Finance 2 ZUBER COMPLEX 4 AERODROME CIRCLE KOTA 324007 | KOTA | KOTA | RAJASTHAN | 324007 | ₹85.0 L | Admitted-Finance |
| 4 | Rejected-Technical | - | Rejected-Technical firm does not fulfill QR |
| 5 | Rejected-Technical C 83 SECTOR 88 NOIDA GAUTAM BUDDHA NAGAR UTTAR PRADESH 201305 UDYAM DL 03 0001671 | GAUTAM BUDDHA NAGAR | UTTAR PRADESH | 201305 | - | Rejected-Technical firm does not fulfill QR |
| Sl No | Description | Qty | Unit | ABHISHEK ENTERPRISES | RIR POWER ELECCTRONICS LIMITED | ARVP POWER SOLUTIONS |
|---|---|---|---|---|---|---|
| 1.00Rectifier | ||||||
| 1.01 | Supply of Thyrister Control Rectifier Type - TCR (CC/CP)14.4Volt/4050 Amp for Hydrogen Generation Plant under Buy back Scheme with ETC.
Technical specifications
1. Input AC Voltage:-415Volts, variation+-5%
2. Frequency:-50Hz.
3. No. of Phase:-3(4Wire)
4. Ambient Condition:-Operating Temperature Range 45 to 48 degree & Humidity <90-95%
5. DC output Voltage:-14.4VDC
6. Max. DC output Current:-4050A DC Max.
7. Rated output:-Range 58 to 60KW
8. Mode of operation:-Constant Current or Constant Voltage
9. DC operating Voltage Control:-10-100%
10. Current Stability:-
+-1%of rated Value for load variation from1 0% to 100% | 2 | Nos | 64,00,000 ₹75.5 L | 46,43,000 ₹54.8 L | 53,00,000 ₹62.5 L |
| 1.02 | ETC Work of Thyrister Control Rectifier Type - TCR (CC/CP)14.4Volt/4050 Amp | 2 | Job | 4,00,000 ₹4.7 L | 5,20,000 ₹6.1 L | 1,00,000 ₹1.2 L |
| 1.03 | Buyback cost of existing Old Rectifiers. | 2 | Nos | 4,00,000 ₹4.7 L | 4,00,000 ₹4 L | 80,000 ₹94,400 |
Updated dates
Tender Value
₹70.8 L
EMD Value
₹1.4 L
Closing Date
21 Feb 2026, 11:30 amClosed
OFFICE OF THE SUPERINTENDING ENGINEER (MM)
O/o The SE (MM), KaTPP,Village Undal,Jhalawar
Supply and Erection, Testing and Commissioning of Rectifiers (02Nos.) Supply and Erection Testing and Commissioning of Rectifiers 02Nos 14.4V 4050A at hydrogen generation plant of KaTPP RVUN Jhalawar Rajasthan under buyback scheme
2025_RRVUN_523396_1
RRVUNL/KaTPP/ TN-1239(MM)
Open Tender
Electrical Goods/Equipments
KaTPP Near Undal Village Dist Jhalawar Rajasthan
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,180
Sr AO KaTPP
₹1.4 L
24 Apr 2026
1 Jan 2026
21 Feb 2026
1 Jan 2026
21 Feb 2026
1 Jan 2026
Supply of Thyrister Control Rectifier Type - TCR (CC/CP)14.4Volt/4050 Amp for Hydrogen Generation Plant under Buy back Scheme with ETC. Technical specifications 1. Input AC Voltage:-415Volts, variation+-5% 2. Frequency:-50Hz. 3. No. of Phase:-3(4Wire) 4. Ambient Condition:-Operating Temperature Range 45 to 48 degree & Humidity <90-95% 5. DC output Voltage:-14.4VDC 6. Max. DC output Current:-4050A DC Max. 7. Rated output:-Range 58 to 60KW 8. Mode of operation:-Constant Current or Constant Voltage 9. DC operating Voltage Control:-10-100% 10. Current Stability:- +-1%of rated Value for load variation from1 0% to 100%
ETC Work of Thyrister Control Rectifier Type - TCR (CC/CP)14.4Volt/4050 Amp
Buyback cost of existing Old Rectifiers.
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.24 MB
TN1239.pdf
Tender Documents • 3.54 MB
BOQ_933687.xls
BOQ • 0.34 MB
Download all tender documents and submit your bid