EXECUTIVE ENGINEERING UPSIC KANPUR
EXECUTIVE ENGINEERING UPSIC KANPUR
External Electrification Work of Industarial Estate Kabrai Mahoba
2026_MSME_1119416_1
458/SE1/2025-26
Open Tender
Electrical Works
90 days
KANPUR
Please refer Tender documents.
2 documents required · 2 mandatory
₹5,025
EXECUTIVE ENGINEERING UPSIC KANPUR
₹2.1 L
KANPUR
18 Mar 2026
23 Feb 2026
6 Mar 2026
23 Feb 2026
5 Mar 2026
23 Feb 2026
26 Feb 2026
Support for 11 KV overheaa line as per technical specification, approvea drawings and scot of workSTP-11M IS 410 SP-55 UPPCL STOCK RATE ITEM NO-H 002975
Pre-fabricated Hot dip Galvanised steel items liLe V cross arm, top clamp, DC cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, back clamp, triuisi"ormer mounting structure etc made of MS Channels (l00x50x6mm), MS angle (65x65x6mm), MS dats (65x8mm) of given sizes for over head structures as per technical specification, approved drawings and scope of work.33 KV Line Pole Top Bracket- 3.625 Kg. Each DSR Civil 10.25.2
Switch yard illumination system33 KV Line V Cross Arm - 15.94 kg. Each UPPC Sl. No. 37
M.S. Channel (X-arm) 100x50x6mm-2200 mm for H-Pole - 17.38 Kg. Each DSR Civil 10.25.2
M.S. Angle 50x50x6mm-2860 mm for Bracing H-Pole - 12.87 Kg. Each DSR Civil 10.25.2
Half Clamp- 1.47 Kg. DSR Civil 10.25.2
Full Clamp - 2.325 Kg.DSR Civil 10.25.2
MS Nuts, Bolts with Washers as per technical specification, approved drawings and scope of work.GI Nuts, Bolts & Washer off all required sizes - 10 Kg
Hot dip Galvanised Eye Screw Bolt 9"x5/8" (19 No.) - 0.483 Kg. MR
Stay Set (Galvanised) with 50x8 mm stay clamp, stay insulator (2 Nos.), anchor plate (200x200x6), nut bolts, 2 Nos turn-buckles, 1.8 m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete as per technical specification, approved drawings and scope of work.MR
Insulator and hardware as per technical specification, approved drawings and scope of work.33 KV polymeric Disc insulator 45 KN along with suitable hardware fittings Sl.No. 24 & 28
33 KV Polymeric Pin Insulators with GI PIN Sl.No. 33 & 35
Earthing arrangement as per technical specificatons, approved drawings and scope of work.40 mm dia., 3000 mm long GI pipe earth electrode with test link, RCC pit, RCC cover plates on GI frame, bentonite powder and other accessories complete MR
Spike Earthing 20mm solid Rod MR
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
PG Clamps for 30/50/80/100 mm2 MR
Barbed Wire MR
Danger Plate (Enamelled with Clamp) MR
Phase Indication Plates for each phase set of 3 (On H•Pole & d Pole) MR
ACSR conauctor, Dog type (100 sq mm) UPPCL Sl.No. 41
5 MVA 33/11 KV Power Transformer Three phase CRGO cooper wound as per UPPCL Stock SCH NO- V 20215
33KV Isolators (630 Amps), with clamps SCH NO-S 303002
33 KV VCB, 36 KV, 630A with 1000 MVA (16 KA for 1 second) rupturing capacity VCB for out door use. Sl.No. 103
33 KV C&R panel 24 V DC Operated suitable for controlling of one T/F (With Differential protection, master relay & 10 window auxre relay) Sl.No. 107
Battery Charger 24Volt Sl.No. 104
Battery Set 24Volt Sl.No. 105
33KV Lightening Arrestor Sub-Stn Type 30KV 10KA with surge counter. H 403406
33KV CTs 400-200/5-5-5-5 A with Junction Box Sl.No. 66
33KV CTs 200-100/5-5-5-5 A with Junction Box V 30141
33KV PTs with junction box Sl.No. 58
33KV Post insulators Sl.No. 79
11KV Disc insulators 45KN T & C Type H201102
Disc Fitting (T&C Type) Sl.No. 28
11KV 8 panel board 24V DC operated with 1 No. I/C panel S403996
11KV 8 panel board 24V DC operated with 6 No. O/G Panel and 1 No. Capcitor Control Panel S401910
11KV Buscoupler Sl.No. 111
LT Distribution board for 33KV Sub-Stn Sl.No. 114
11 kV automatically Switched Capacitorbank 1.8 MVAR, (with isolator, structure and all allied material )
Steel Structures galvanised(as per drawings) MRStructure for 33 KV CT Wt. 87.62 Kg M R
Structure for 33 KV PTs Wt. 87.62 KgMR
Structure for 33 KV LA Wt. 76.38 KgMR
Structure for 33 KV Post Insulators Wt. 76.38 Kg MR
Structure for 33 KV Isolator Wt. 288.36 Kg MR
Structure for L&E Switch Wt. 288.36 Kg MR
Structure for 11 KV NCT Wt. 92.37 Kg MR
Galvanised Gantry Towers - 2xDB-2, 2xDT-2, 2xDT-3 per s/stn MR
ACSR Conductor 0.2 sq in(Panther) MR
11KV Single core XLPE cable 300mm2 for Incoming Feeder C 301702
S/C 300 mm Sq. cable Termination Kit indoor Sl.No. 84
S/C 300 mm Sq. cable Termination Kit outdoor Sl.No. 84
11KV 3 core XLPE cable 185mm2 for O/G Feeders C 301605
11KV 3 core XLPE cable 300 mm2 for capacitor bank C 301702
11KV 3 core XLPE cable 70mm2 for S/Stn T/F. C 301401
3/Cx185MM Sq. outdoor Heat shrinkable Termination Kit for O/G Sl.No. 82
3/Cx300 MM Sq. outdoor Heat shrinkable cable box for capacitor Sl.No. 84
3/Cx300 MM Sq. indoor Heat shrinkable cable box for capacitor Sl.No. 84
LT PVC cable 2C X 10 mm2 for yard light RA-9
un armoured Copper control cable 2C X 4mm2 RA-10
un armoured Copper control cable 2C X 6mm2 RA-11
un armoured Copper control cable 3C X 4mm2 RA-12
un armoured Copper control cable4C X 4mm2 RA-13
un armoured Copper control cable6C X 4mm2 RA-14
un armoured Copper control cable 7C X 2.5mm2 RA-15
un armoured Copper control cable 10C X 2.5mm2 RA-16
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Upto 35 sq. mm
MS Channel galvanised of various size MR
MS Angle Iron galvanised 50 X 50 X 6 mm MR
MS Flat galvanised 50 X 6 mm MR
MS Flat 75x8 MM for Earth mat in switch yard MR
Switch yard illumination systemSupply & fixing of 8mtr GI Octagonal Pole of approved make (top dia 70mm, Bottom dia 130 mm and base plate 12mm thik) having 3mm thikness with single arm bracket (1 Mtr length) on RCC foundation including the cost of foundation, foundation bolts, excavation & back filling and Required T&P completee in all respect. MR
Supply and fixing of LED Street light Fitting having die cast aluminium body and diffuser with driver set suitable for 75 to 90 Watt. Confirming to IP 66 and above Protection complete in all respect. CAT- AAA RA-8
Fire Fighting/Safety eqpt for Control roomSupply and fixing of fire extinguisher, ABC Type 6.00 kg. capacity (ISI Marked IS : 15683 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. MR
Supply and fixing of C02 type fire extinguisher 6.5 kg. capacity (ISI Marked IS : 2878 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. MR
Fire Fighting/Safety eqpt for yardSupply and fixing of fire extinguisher, ABC Type 9.00 kg. capacity (ISI Marked IS : 15683 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. MR
CO2 type Fire extinguisher 22.5 Kgs MR
Fire Buckets (capacity) - 10 Ltrs MR
100mm dia ISI marked GI Pipe with clamps MR
11 KV 400 Amps. GO Switch complete with handle, pipe & Sporting channel Sl.No. 92
11 KV LA type 9 KV Heavy Duty MR
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. PWD 2018 703
Earthing Rod Wt. 6.175 Kg MR
G.I. Pipe 40 mm dia 6 mtr. Long for earthing MR
Premier Insulating Mat - "B Class" as per IS 15652:2006 MR
1 No. Table, 4 No. Chair, Wall clock, Safety Charts, Safety Tool Kit & Medical Kit, earth stick-1 MR
PG Clamps for Panther conductor MR
MS Nuts & Bolts off size MR
GI nuts & bolts off size MR
H. T. SYSTEM STP-11M IS 410 SP-55 Support for 11 KV overheaa line as per technical specification, approvea drawings and scot of work
Pre-fabricated Hot dip Galvanised steel items liLe V cross arm, top clamp, DC cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, back clamp, triuisi"ormer mounting structure etc made of MS Channels (l00x50x6mm), MS angle (65x65x6mm), MS dats (65x8mm) of given sizes for over head structures as per technical specification, approved drawings and scope of work.11 KV Line Pole Top Bracket 3.625 Kg. each
11 KV Line V Cross Arm - 15.94 kg. each
M.S. Channel (X-arm) 100x50x6mm-2200 mm for H-Pole (2 No.) - 17.38 Kg. each
M.S. Angle 50x50x6mm-2860 mm for Bracing H-Pole (2 No.) - 12.87 Kg. each
Half Clamp (24 No.) - 1.47 Kg.
Full Clamp (10 No.) - 2.325 Kg.
GI Nuts, Bolts & Washer off all required sizes
Hot dip Galvanised Eye Screw Bolt 9"x5/8" - 0.483 Kg.
Stay Set (Galvanised) with 50x8 mm stay clamp, stay insulator (2 Nos.), anchor plate (200x200x6), nut bolts, 2 Nos turn-buckles, 1.8 m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete as per technical specification, approved drawings and scope of work.
Insulator and hardware as per technical specification, approved drawings and scope of work11 KV polymeric Disc insulator 45 KN along with suitable hardware fittings
11 KV Polymeric Pin Insulators with GI PIN
Earthing arrangement as per technical specificatons, approved drawings and scope of work.40 mm dia., 3000 mm long GI pipe earth electrode with test link, RCC pit, RCC cover plates on GI frame, bentonite powder and other accessories complete
Spike Earthing 20mm solid Rod
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
PG Clamps for 30/50/80/100 mm2
Barbed Wire
Danger Plate (Enamelled with Clamp)
Phase Indication Plates for each phase set of 3 (On H•Pole & d Pole)
ACSR conauctor, Dog type (100 sq mm)
LT Distribution Work & Street Light Work Supply, Installation, testing and commissioning of 250 KVA. 11/0.433 KV, 3 Phase, 50Hz, Dyn 11, Oil type, ( UPPCL approved make) copper wound transformer with Off load tap changing arrangement on HV side in steps of +/- 2.50%, +/- 5% , having cable end boxes on HV side and 500 Amp. bus trunking arrangement on LV side complete with all accessories i/c first filling of filtered dehydrated oil and confirming to IS 2026 (Part 1 to Part 5) & as per specification attached complete in all respects as required at site.MR Note:Foundation work for transformer is not included in Electrical works it will come on Civil work.
Supply & Stringing of LT AB Cable of 3x120+1x95+1x50sqmm MR
Supply & Laying of 4C X 25sqmm Al. Unarm. Cable MR
Supply & Installation of 3Phase Distribution Box MR
Supply & Installation of C- Type / Holding Clamp MR
Supply & Installtion of Eye hook Clamp MR
Supply & Installation of Nut & Bolts with washer MR
Supply & Installation of Suspension Clamp MR
Supply & Installation of Dead end Clamp MR
Supply & Installation of Piercing Connector 120Sqmm MR
Supply & Installation of Piercing Connector 95Sqmm MR
Supply & Installation of PG Clamp for ACSR Conductor MR
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.DSR 5.2
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.DSR 5.6
Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required.DSR 5.8 (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm)
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)DSR 5.9
Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required.DSR 5.10
Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.DSR 5.11
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.DSR 5.16
Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required.DSR 14.14300 mm dia
Supply and fixing of LED Street light Fitting having die cast aluminium body and diffuser with driver set suitable for 110 to 130 Watt. Confirming to IP 66 Protection complete in all respect. CAT- AAA PWD-2024 1425
Supply & Installation of Single Arm Bracket for fitting of Street Light MR
Installation,Commisioning and Testing Charge of solar high mast and street light
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.48 MB
BOQ_2081551.xls
BOQ • 0.43 MB
NITElectrificationofIndustrialEstateMahoba.pdf
Tender Documents • 1.42 MB
Download all tender documents and submit your bid