| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.1 LAccepted-AOC G 86 DATA RAM SECTOR 18 ROHINI NEW DELHI DELHI 110085 | NORTH WEST DELHI | DELHI | 110085 | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹23.0 L+₹1.2 L (5.61%)Rejected-Finance A 3 257 JANAKPURI NEW DELHI 110058 | WEST DELHI | DELHI | 110058 | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹25.7 L+₹3.9 L (17.9%)Rejected-Finance | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹27.0 L+₹5.2 L (24.0%)Rejected-Finance BARIYAWAN BARIYAWAN BARIYAWAN BARIYAWAN AMBEDKAR NAGAR UTTAR PRADESH 224210 | AMBEDKAR NAGAR | UTTAR PRADESH | 224210 | L4 | Rejected-Finance Other than lowest | |
| 5 | L5₹30.1 L+₹8.4 L (38.5%)Rejected-Finance 67 AASANI BAS PALANA PALANA BIKANER BIKANER RAJASTHAN 334402 UDYAM RJ 08 0063520 | BIKANER | RAJASTHAN | 334402 | L5 | Rejected-Finance Other than lowest |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
2 Jul 2021, 6:00 pmClosed
GE (N) DELHI CANTT-10
GE (N) DELHI CANTT-10
REPAIR MAINT OF INTERNAL ELECTRIFICATION WORK INCL REPLACEMENT OF UNSV INTERNAL FITTINGS FIXTURES WIRING MCBs MCB DBs WITH CONNECTED WOKRS AT OFFRS MD ACCNS AT KIRBY PLACE MAP KIRBY PLACE STATION ROAD AND MOUD ROAD AND REPAIR MAINT OF CEILING A
2021_MES_451044_1
GE/NORTH-11/2021-22
Open Tender
Civil Works
Item Wise
270 days
GE (N) DELHI CANTT-10
as per NIT
8 documents required · 8 mandatory
₹500
Yes
GE (N) DELHI CANTT-10
₹80,000
Yes
19 Aug 2021
12 Jun 2021
5 Jul 2021
12 Jun 2021
2 Jul 2021
26 Jun 2021
Amount
Taking down ceiling fan of any sweep by unscrewing nut/bolts from its position and fixing the same to its original place after necessary cleaning, oiling, greasing, replacement of defective parts bush, bearing, condenser, flexible wire, down rod, canopies. (Note : Rubber bush, bearing, capacitor, copper flexible wire, down rods, canopies as supply only rates and fixing charges for spare parts shall deemed to be included)
Rewinding of burnt winding of stater of the ceiling fan 1200 mm sweep with matching gauge and turns of super enamelled copper wire leathenic paper, glass sleeves etc including varnishing,heating the windings as per manufacturer design and reassembling the same complete testing all as specified and as directed.
All as per above but for 1400 mm Sweep
Painting of ceiling fan of any sweep complete with one coat of 1st grade quality synthetic enamel paint by spraying including preparation of old painted surfaces to remove any type of sticky dust, oil marks etc and filling cavities with fillers and writing letters and numbers complete all as specified and as directed.
Taking down Exhaust/Ventilation fan of any sweep by unscrewing nut/bolts from its position (high rise bldgs up to 8 storey height) and fixing the same to its original place after necessary cleaning, oiling, greasing, replacement of defective parts bush, bearing, condenser,flexible connection wire,louvers,shutters, specified and directed. (Note : Rubber Bush, Gun Metal Bush, bearing, capacitor, twin core twisted copper flexible wire, Louvers,shutters, winding and paintng are measured and paid separately as supply only rates and fixing charges for spare parts shall deemed to be included)
Rewinding of burnt winding of the Exhaust fan up to 300 mm to 450mm dia with matching gauge and turns of superenamelled copper wire leathenic paper, glass sleeves etc including varnishing,heating the windings as per manufacturer design and reassembling the same complete testing all as specified and as directed.
All as per above but 380/450mm Sweep
All as per above but 600 mm Sweep
All as per above item but ventilation fan up to 200mm Sweep.
Painting of exhaust fan of any sweep complete with one coat of 1st grade quality synthetic enamel paint by spraying including preparation of old painted surfaces to remove any type of sticky dust, oil marks etc and filling cavities with fillers and writing letters and numbers complete
Taking down pedestal/wall mounted fan of any sweep by unscrewing nut/bolts from its position and fixing the same to its original place after necessary cleaning, oiling, greasing, replacement of defective parts bush, bearing, condenser,flexible connection wire and re-winding all as specified and directed. (Note : Bush, bearing,capacitor, twin core twisted copper flexible wire and winding are measured and paid separately as supply only rates and fixing charges for spare parts shall deemed to be included)
Rewinding of burnt winding from the stater of the pedestal/wall mounted fan any sweep with matching gauge and turns of superenamelled copper wire leathenic paper, glass sleeves etc including varnishing,heating the windings as per manufacturer design and reassembling the same complete testing all as specified and as directed.
Supply only for ball bearing number of 6201 to 6204 as required for fan complete (Make : SKF/NBC)
Supply only rubber bush for shackle with bolt, nut and lock pin suitable for ceiling fan
Supply only twin twisted copper flexible wire of size 1.0 sqmm
Supply only capacitor 0.8/1 Mfd, 240 Volts.(Make/Model- as per sample)
Supply only capacitor 2.5 Mfd, 240 Volts.
All as per above but 3.15 Mfd.
All as per above but 4.0 Mfd.
Supply only PVC canopy for ceiling fan
Supply only down rod for ceiling fan of 1' long, colour match with existing fan complete all as directed
All as per above but 2' long
All as per above but 5' long
S&F in replacement Fan Hook made out of MS Flat Iron of size 50x6mm of required shape at site incl nut, bolt and washer for fixing of C/fan complete all as directed
M&L in repair for GI tubing 40 mm bore (medium grade) for fixing of ceiling fans and make good the disturbed wall surface and all as specified and directed.
M&L for ceiling fan blade suitable for 1200mm sweep complete
All as per above but for 1400mm sweep
S&F in replacement louvers with shutter metallic body suitable for exhaust fan upto 450mm sweep with necessary fixing accessories after taking down existing all as specified and directed. (Note : Louver Shutter are to be replaced up to high rise bldg/8 storey including all necessary T&P and fixing arrangement by the contractor)
S&F in replacement louver with shutter plastic body suitable for ventilation fan upto 250 mm sweep with necessary fixing accessories after taking down existing all as specified and directed. (Note : Louver Shutter are to be replaced up to high rise bldg/8 storey including all necessary T&P and fixing arrangement by the contractor)
M&L for exhaust fan blade (metal body) suitable for 300/380/450/600 mm sweep for exhaust fan complete all as directed (Make as per sample)
M&L in replacement ventilation fan blade (PVC type) suitable for 200/250mm sweep complete (Make as per sample)
All as per above but for 300mm sweep
M&L in repair for electronic fan regulator flush type, 5 stepped type complete all as directed
Supply and fixing in repair of High speed ceiling fan in white colour 1400mm sweep 220-240 volt with one set of 3 blades, down rod, hanger clamp PVC conopy complete and UNSV ceiling fan depositing in E/M store yard.
Supply and fixing in repair of 300mm dia, 900 RPM, exhaust fan, heavy duty with louver shutter, frame, blades complete and unsv Ex fan depositing in E/M store yard all as directed
All as per above item but 380mm sweep
All as per above item but 450mm sweep
Supply and fixing in repair of 400mm sweep, wall mounting fan, oscalating type complete and UNSV fan deposit in E/M store yard complete all as directed
Supply and fixing in repair of 200/225/250mm dia, 900 RPM, fresh air fan woth plastic louvers incl frame complete and UNSV fan depositing in E/M store yard all as directed
Taking down carefully electric geyser of any type and capacity by disconnecting electric and water supply connection, opening nut, bolt, washer and replacing the defective parts and reassembling after cleaning and replacing defective parts and re-installing the same in original position and making necessary electric and water supply connection and testing complete all as specified and directed. (Note: Spare items shall be measured and paid seperately as supply only under relevant items)
Supply only geyser inner water tank 35/50Ltrs capacity steel body as per sample ,duly tested complete all as specified and directed.
All as per above item but 25 Ltrs capacity
Supply only of Heating element capacity 1.5 KW (Round/Triangular) ISI marked suitable for geyser (as per sample) complete all as specified and directed.Make : as per sample
All as per above item but capacity 2 KW.
Supply only thermostat suitable for 50/35/25 ltrs capacity geysers (Make :- as per sample)
Supply only Heavy duty hot water connection, SS rope threaded type with brass unions at both ends, 45cm long 15mm bore complete.
Supply only cold water connection, PVC connection with brass unions at both ends, 45cm long 15mm bore complete.
Supply only replacement of safety valve/Pressure release valve for geysers of any capacity/ type
Supply only indicator lamp Red/Green suitable for geyser of any type/capacity (Make as per sample)
Supply only geyser base plate assembly of any capacity any model all as specified and directed complete (Make as per sample)
Supply only geyser top and bottom cover any capacity any model all as specified and directed complete (Make as per sample)
S&F in replacement of glass wool heat resistance type of exist type (8 kgs) for 25 to 50 ltrs capacity geysers complete
S&F in replacement of outer cover MS sheet/ABS body of geysers 25 to 50 Ltrs capacity complete
M&L soldering/brazing inner geyser tanks 50/25 liters with brass solder and refixing after testing the leakage complete incl replacement of rubber packaging ring heat resistance type all as specified directed complete.
Material & Labour for spray painting 25 to 50 Ltrs capacity with two coats of white synthetic enamel paint (1st quality approved brand ) after preparation of surface all as specified and directed complete.
M&L in replacement of Plug top, 3 pin, 05 amps, 230 volt
M&L in replacement of Plug top, 3 pin, 15 amps, 230 volt
S&F in repair PVC insulated and sheathed flexible cable 3 core Multi-stranded copper conductor size 2.5 Sqmm 1100 volt grade after taking out old unserviceable one including electric connection complete all as specified and directed.
Supply and fixing in repair of desert/Air cooler of body size 25"x25"x32", made out of corrosion resistant, 18 SWG GI sheet duly powder coated paint with 500mm sweep copper wound fan motor kit 180 watt with metallic blade, ISI marked, 1400 RPM, 230 volt AC, tank capacity not less than 100 ltr, incl plastic submersible pumps, electronis fan regulator with P/switch, desert cooler to be fitted with 6mm thick plywood to cover the gap as required size at existing window and old unsv desert cooler depositing in E/M Store yard complete all as directed
S&F in replacement fan motor kit incl blade, steel body for desert cooler of flow capacity upto 4000 Cum/Hr complete all as directed (Make :- Khaitan/CG/Bajaj)
M&L fan blade (PVC type) suitable for desert cooler up to 450mm sweep fan complete all as directed (Make as per sample)
S&F in repair plastic submersible pump suitable for desert cooler any size complete all as directed (Make as per sample)
Supply and fixing 6mm thick plywood sheet (ISI marked) waterproof fixed in window including cutting as desired size for passing air of desert cooler.
S&F desert cooler pad (set of three) made out of wood wool etc suitable for desert cooler of any size.
S&F in replacement desert coolers body of required size made out of 18 SWG MS sheet complete including inside panel made out of 22 SWG MS sheet complete and grill duly painted with two coat synthetic enameled paint over one coat of red oxide inside complete all as directed.
S&F in repair PVC flexible pipe of high density for 15 mm bore for desert cooler of any size complete
M&L for servicing of any type and any make of split type AC/Window AC of 2 ton/1.5 ton capacity complete by dismantaling of AC and re-fixing after cleaning and replacement defective parts, dismantling the cover of condensing unit carefully and carry out servicing cleaning of the external surface (both side) throughly with the help of descaling chemical, brush, plain water and dry properly by using air blower for cleaning air dust deposited on epqt and charging of gas in adequate quantity as required re-fixing after repair complete
Supply and charging of refrigerant gas R-134a/R-22 for any type and capacity of Window/Split AC and checking for leakage (if any) after charging of gas complete
S&F in replacement Motor double shaft 1/5 HP capacity for window type AC 1.5 ton/2 ton capacity complete (Make : As per sample)
S&F in replacement Motor single shaft 1/5 HP capacity for split type AC 1.5/2.0 ton capacity complete (Make : As per sample)
S&F in repair thermostat for split AC/Window AC of capacity 1.5/2 Ton complete (Make : As per sample)
S&F of filter for split AC of 1.5/2 TR cap including taking out the old u/s filter complete
S&F of Reverse valve (heating and cooling type) suitable for split AC of capacity 1.5 TR by taking out of old u/s valve from the outdoor unit of AC and fixing of new valve by breazing/soldering and charging of adequate quantity of gas and testing on completion complete all as directed
All as per above but for split AC of 2.0 TR capacity
S&F in replacement hermetically sealed rotary type compressor unit of capacity 1.5 TR and charging of adequate quantity of refrigerant gas and testing on completion complete
S&F in repair Power Circuit Board (PCB) suitable for split type AC of capacity 1.5TR / 2.0 TR complete
S&F in repair switch piano flush type, 6 amps, 230V AC,single pole, one way
S&F in repair switch piano flush type 16 amps, 230V AC single pole one way
S&F in repair socket out let multipurpose suitable for 2 pin and 3 pin 6 amp flush type
S&F in repair socket out let multipurpose type, for 3 pin 6 and 16 amp flush type.
S&F in repair MCB SP, 10-32 amps, 240 volts, 'C' series, 10 KA breaking capacity complete
S&F in repair MCB SPN 63 amp, 240 volts, 'C' series, 10 KA breaking capacity & connection complete
S&F in replacement pressed sheet metal enclosure (MCB DB) 2 way, single phase and neutral , single door type, 240 volts, DB to be grouted on wall including disturbed surface to match existing surface complete all as specified & directed
M&L in replacement for two single core (submain) PVC insulated cable with 4 sqmm nominal cross sectional area stranded copper conductor and one single core green PVC insulated 2.5 sqmm stranded copper conductor earth continuity cable drawn through non metallic rigid PVC conduit 20 mm dia concealed in wall including all conduit and fixing accessories complete
S & F in repair sheet metal enclosure with Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB with 20 Amps complete
S & F in repair industrial type two pin and earth plug top complete
M&L in repair PVC casing caping of size 20 x 12mm, ISI marked, incl accessories, screw etc complete all as directed
Taking down carefully copper / aluminium point wiring (light / fan socket or power) complete including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc for taking credit including making good the disturbed surfaces to match with the existing all as specified and directed.
Material and labour for point wiring with 1.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable with and including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC conduit of 20mm dia or higher, medium grade complete with and including all PVC conduit accessories concealed into wall by cutting of chases in wall and replacement of modular metal flush box, modular white cover plate with frame, blanking plate etc suitable for Mylinc / Coral / Sleek model accessories etc and making good to the disturbed surfaces to match the existing complete all as specified and directed for one light / bell point controlled by one, one way switch 06 Amps.
All as per srl item No 89 here-in-before but one fan point controlled by one, one way switch 06 Amps.
All as per srl item No 89 here-in-before but one 3 pin, 06 Amps socket outlet point on independent board controlled by one, one way 06 Amps switch.
All as per srl item No 89 here-in-before but one 3 pin, 06 Amps socket outlet point on same board controlled by one, one way 06 Amps switch.
All as per Serial Item No 89 above but point wiring with 2.5 Sqmm single core FRLS cables and earth continuity wire of 1.5 Sq mm single core FRLS cable for one 3 pin 15 Amps socket out let point controlled by one, one way switch on independent board complete all as specified and directed.
Supply and fixing modular switch, 06 Amps, single pole, one way, 230 volts, one module and IP 20 protection complete all as specified & directed.
Supply and fixing modular bell push with indicator, 06 Amps, single pole, one way, 230 volts, complete all as specified & directed.
Supply and fixing modular switch, with indicator, 16 Amps, single pole, one way, 230 volts, one module complete all as specified & directed.
Supply and fixing modular socket outlet 05 Pin, 06 Amps, 02 module with shutter complete all as specified & directed.
Supply and fixing modular socket outlet 02 in 01, 03 pin, 06 Amps and 16 Amps, 02 module with shutter complete all as specified & directed.
Supply and fixing ding dong bell, AC, 230 volts, single pole complete all as specified & directed.
Supply and fixing ceiling fan regulator, stepped type of 0 to 04 rotary steps, electronic, 02 module, humfree, AC, 230 volts, 100 watts, duly ISI marked complete all as specified & directed.
M&L for point wiring with 1.5 Sq.mm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable with and including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC conduit of 20mm dia or higher, medium grade complete with and including all PVC conduit accessories concealed into wall by cutting of chases in wall and replacement of sunk zinc coated pressed steel terminal box of 1.60mm thick with 3mm thick plastic laminated sheet top cover, brass screws, cup washers etc and making good to the disturbed surfaces to match the existing complete all as specified and directed for One light / bell / buzzer point controlled by one, one way switch 06 Amps.
All as per srl item No 101 here-in-before but one fan point controlled by one, one way switch 06 Amps.
All as per srl item No 101 here-in-before but one 3 pin, 06 Amps socket outlet point on independent board controlled by one, one way 06 Amps switch.
All as per srl item No 101 here-in-before but one 3 pin, 06 Amps socket outlet point on same board controlled by one, one way 06 Amps switch.
All as per Serial Item No 101 above but point wiring with 2.5 Sqmm single core FRLS cables and earth continuity wire of 1.5 Sq mm single core FRLS cable for one 3 pin 15 Amps socket out let point controlled by one, one way switch on independent board complete all as specified and directed.
S&F switch piano flush type, 06 Amps, single pole, one way, 230 volts complete
S&F bell push, flush type, 06 Amps, 230 volts with switch frame complete
S&F switch piano flush type, 16 Amps, single pole, one way, 230 volts with switch frame complete
S&F socket outlet 2 in 1, 5 pin, 06 Amps, flush type, 230 volts with socket frame complete
S&F socket outlet 2 in 1, 3 pin, 06 Amps and 3 pin, 16 Amps, flush type, 230 volts with socket frame complete
S&F ceiling fan regulator , stepped type of 0 to 04 rotary steps, electronic, 2 Module socket type, humfree, AC, 230 volts, 100 watts complete
Supply and fixing ceiling rose, 6 Amps, 230 volts, AC, ISI marked with three equal size terminals and PVC / Polycarbonate insulated body of 50 x 25mm size complete all as specified & directed.
Supply and fixing lamp holder, PVC / Polycarbonate type with back plate suitable for batten fitting including 7W LED bulb complete all as specified & directed.
Supply and fixing in repair decorative wall mounting, fixture with opal PC diffuser suitable for 10/12 watt LED Lamp, lamp holder, including 12 Watts LED bulb of 6500 K of B22 base cap, and all accessories pre-wired including connecting up complete all as specified and directed.
Supply and Fixing in repair surface and wall mounted LED batten 10 watt 2 feet long extruded aluminium housing provided for efficient heat dessipation with polycarbonate diffusser and integrated electronic drive suitable for mirror fittings, all accessories pre-wired including connecting up with twin core flat flexible copper conductor cable of suitable size complete all as specified and directed.
Taking down of exsting u/s tube light fitting and supply and fixing in repair on surface and wall mounted LED batten with polycarbonate housing and initigarated electronic drive 20 Watt fixture 4 feet provided for efficient heat dissipation with policorbonate diffuser and integrated electronic driver and all accessories pre-wired including connecting up with twin core flat flexible copper conductor cable of suitable size with connector block complete all as specified and directed.
S&F in repair ultra modern recess/surface mounting 36 Watts, 2x2 LED flat panel complete with integrated electronic driver, soft-light and glare free symmetrical illumination, suitable for POP ceilings high brightness SMD LEDs, etc including connecting up with twin core flat flexible copper conductor cable of suitable size with connector block complete
Taking down of exiting u/s security light fitting and supply and fixing energy saving LED security light fitting with lens of 45 watts Versatile pressure die-cast aluminium IP 66 roadway luminaire with high power LED as light source comprising with electronic driver and all accessories pre-wired incl connecting up with PVC insulated copper conductor cable 1.5 Sqmm, 3 core as required for connections and suitable GI tube bracket for mounting of light fitting, bend to shape at 140 degree in ‘L’ shape and fixed to wall by means of suitable flat iron clamps, nuts, bolts and washers etc complete all as specified and directed.
Supply and fixing Ventilating fan wall mounted type of 250 mm sweep, 230 volts, AC, 50 Hz capacity, cutting of hole in wall, making of wooden frome, all arrangements for mounting of fan including making good of disturbed surface etc complete and UNSV ventilation fan deposited in E/M Store yard.
Supply and fixing Ventilating fan wall mounted type of 200 mm sweep, 230 volts, AC, 50 Hz capacity, cutting of hole in wall, making of wooden frome, all arrangements for mounting of fan including making good of disturbed surface etc complete and UNSV ventilation fan deposited in E/M Store yard.
Material and labour for sub main wiring with 04 Sqmm nominal cross sectional area, two single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLSH copper conductor cable with and including continuous earth wire of size 2.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLSH copper conductor cable drawing into and including rigid non-metallic PVC concealed conduit of 25 mm dia, medium grade with all conduit accessories and connected to common earth dolly with suitable copper lugs including all cutting / chases etc in walls and making good to the disturbed surfaces to match the existing complete all as specified & directed, including taking down old sub main wiring.
All as above but 06 Sqmm nominal cross sectional area.
All as above but 10 Sqmm nominal cross sectional area, four single core, with and including continuous earth wire of size 06 Sqmm nominal cross sectional area.
Supply & fixing in repair Modular type sheet metal enclosure SPN type with a two pin and earth plug and socket complete with and including MCB, SP, AC, 230 volts of 32 Amps, 'C' curve 10 KA breaking capacity and flush to wall including all cuttings & chases etc in wall and making good to the disturbed surfaces to match the existing complete all as specified & directed.
Supply and fixing in repair sheet metal enclosure distribution board, single pole and neutral, AC, 230 volts, 08 way, with 200 Amps rated copper bus bar and metal door with IP - 43 & IK 09 protection along with cable end box for above DB and flush to wall including all cutting etc in wall and making good to the disturbed surfaces to match the existing complete all as specified directed.
Supply and fixing in repair sheet metal enclosure distribution board triple pole and neutral (VTPN), AC, 440 volts, 04 ways with 200 Amps rated copper bus bar and metal door with IP 43 & IK 09 protection along with cable end box for above DB and flush to wall including all cutting etc in wall and making good to the disturbed surfaces to match the existing complete all as specified and directed and comprising of the following:- Make :-Legrand/Havells/Indoasian/Schneider (a) MCCB, 125 Amps, 04 pole, AC, 415 Volts of 16 KA breaking capacity complete - 01 No. (b) MCB, SP, AC, 230 volts of 06 to 32 Amps, "C" curve, 10 KA breaking capacity - 12 Nos.
Supply and fixing in repair MCB, SP, AC, 230 volts of 06 to 32 Amps capacity "C" curve, 10 KA breaking capacity and making connections by using suitable copper lugs complete all as specified & directed.
Supply and fixing in repair MCB, DP, AC, 230 volts of 63 Amps capacity "C" curve, 10 KA breaking capacity and making connections by using suitable copper lugs complete all as specified & directed.
Supply and fixing in repair MCB, TPN , AC, 415 volts of 40 Amps capacity "C" curve, 10 KA breaking capacity and making connections by using suitable copper lugs complete all as specified & directed.
Supply and fixing in repair 40 Amps 4 Pole 30 mA RCD add on block 10 KA rated conditional short circuit current (Icc) 35 sqmm terminals, dual position DIN Clip, confirming to IEC 60947-2 and 40 Amps 4 pole 'C' type MCB Confirming to IS/CE Marked as per IS/IEC60898-1, rated short circuit breaking capacity Icn 10 KA, enerergy limitation class 3, line load reversiblity, 35 sqmm terminals, biconnect terminals all as specified and directed by Engr-in-charge.
Supply & fixing in repair MCCB, 125 Amps, 04 pole, AC, 415 Volts of 16 KA breaking capacity complete all as specified & directed.
Material & labour for earthing complete with galvanised mild steel earth plate electrode 60cmx60cmx6mm thick buried vertically in ground (earth pit not less than 2.25meter deep below ground level) with top edge of the plate not less than 1.5meter below normal ground level steel earth plate connected with GI wire 04mm dia by means of lug, bolts, nuts, check nuts, washers of galvanised iron or steel GI protection pipe 15mm bore light grade all as shown in elect plate No 3 on serial page No 497 of SSR part I - 2009 and connecting to main switch board / Main DB’s including excavation, earth work, salt and charcoal dust mixed and packed 150mm thick around GI earth plate, GI pipe medium grade 20mm nominal bore watering pipe GI sheet funnel wire mesh, concrete pit, RCC cover 40mm thick in PCC 1:2:4 type B1 duly reinforced with MS Bars 6mm dia at the rate of 75mm center to center both way with 12mm dia lifting handle and pit / chamber in PCC 1:3:6 type C1, Angle iron 40mmx40mmx3mm frame for pit cover including testing on completion complete all as specified and directed.
Sch of Credit- Total contract sum shall be calculated after deduction of Sch of Credit amount Credit amount - Rs. 65588.00
M/s Adhikari construction co.
M/s S.G. BUILDERS
m/s VK construction company
S. S. CONSTRUCTION CO.
Shiv Enterprises
V M CONSTRUCTION
Surjit and Sons
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .