Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.7 LAdmitted-Finance 1 225 5 6 SADAR BAZAR DELHI CANTT 110010 | NEW DELHI | DELHI | 110010 | L1 | Admitted-Finance | |
| 2 | L2₹39.8 L+₹2,984.20 (0.08%)Admitted-Finance WZ 1000 NANGAL RAYA PANKHA ROAD SOUTH WEST DELHI DELHI 110046 | DELHI | SOUTH WEST DELHI | DELHI | 110046 | L2 | Admitted-Finance | |
| 3 | L3₹42.9 L+₹3.2 L (7.97%)Admitted-Finance | L3 | Admitted-Finance | |
| 4 | L4₹43.3 L+₹3.6 L (8.95%)Admitted-Finance RZ 212F D BLOCK RAJ NAGAR PART II PALAM COLONY NEW DELHI 110077 | SOUTH WEST | DELHI | 110077 | L4 | Admitted-Finance | |
| 5 | L5₹43.9 L+₹4.1 L (10.3%)Admitted-Finance 3788 SHAH GANJ GB ROAD NEW DELHI 110006 | NEW DELHI | DELHI | DELHI | 110006 | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | MV Engineers And Contractors L4 | Commercial Traders L5 | mayur enterprises L2 | M/s JAIMAA ASSOCIATES L3 | Vijay Electricals L6 | M P TYAGI ENGINEERS AND CONTRACTORS L1 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Supply, installation, testing and commissioning of transformer step down, outdoor type copper wound Level-III ,IS 1180, 11KV/433 Volts (at no load) AC 3 phase 50 Hz 400 KVA capacity, core type, oil immersed naturally cooled, oil natural air natural (ON/AN), with external cooling tubes, delta connected on primary side (HT) and star connected on secondary side (LT) in accordance with vector group DYn-11 with neutral brought out on secondry side (LT) and having taping at ±10% in steps of 2.5% on HT side to be changed by means of hand operated off load tap changer. The maximum temperature rise should not exceed 40 degree celsius in oil and 45 degree celsius in HT/LT winding when measured by resistance method after continuous full load run on an ambient temp of 40 degree celsius transformer shall be of BOLTLESS core design. Transformer shall be double wound, core type with low loss, non ageing, high permeability prime grade crgo with M4 grade or better, perfectly insulated and clamped to minimize noise and vibrations. The transformer shall be IS/IEC 60076and as per IS-1180 part - I of 2014 marked, Including the cost of PCC/RCC foundation including necessary framework & fencing in perimeter location for placing of TRANSFORMER complete all as per IE/IS specification and shall comprise of the following :- | 1 | Each | 14,99,000 ₹14,99,000 | 14,58,370 ₹14,58,370 | 14,00,000 ₹14,00,000 Lowest | 14,59,000 ₹14,59,000 | 18,90,000 ₹18,90,000 | 16,99,999 ₹16,99,999 |
| 1.10(a) One cable box on HT side (Primary side) consisting of three nos porcelain bushing with copper rods, complete with nuts and washer with cable glands suitable for reception / taking out 3 core 185 Sqmm, HT 11000 volts grade, XLPE insulated and PVC sheathed, heavy duty , armoured cables including jointing materials complete. (b) One cable box on LT side(secondary side) consisting of four nos porcelain bushing with copper rods,for connected bus ducts complete with nuts and washers, with cable glands suitable for reception / taking out single core 400 sqmm, LT 1100 volts grade, XLPE insulated and PVC sheathed, heavy duty, armoured cables including jointing materials complete. (c ) Conservator with filter type drain valve and oil level guage. (d) De-hydrating breather with first fill of dehydrating agent (Silica Gel). (e) Explosive vent, Thermometer pocket on tank cover, oil level guage, Oil drain filter valve, Lifting lugs,oil filling hole with cap/plug with connection plate complete, Air release valve plug and four nos plain solid cast steel detachable rollers. (f) One no 100 mm dia, dial type thermometer, vapour pressure type, having range 0-120 degree celsius with metal guard having maximum perimeter temperature reading indicator with re-setting device. (g) Two earthing terminals on tank cover to facilitate fixing of 50x6mm galvanised iron earth strip for earthing of body. (h) Rating plate and terminal marking plate. (j) Extra bushing for neutral in the LT cable box for providing independent set of earthing for neutral. (k) First fill of new and unused transformer oil, IS-335 marked, filtered and tested upto 40 KV dielectric strength at 2.5 mm air gap between testing electrodes. (l) Providing adequate size and nos of channels, embeded in floor, for movement of transformer. (m) Tranformer losses shall not exceed the loses mentioned in IS: 1180(2014) Part - I with energy Efficiency level - III. (n) Oil temperator indicator , winding temperature indicator, marshalling box single window, double flit buchholz relay with alarm and trip contact including connection to existing RMU relay with PVC insulated PVC sheathed cable galvanized steel strip or wire armoured electric control cables (Heavy duty) with stranded copper conductor of size 1.5 sq mm 10 core 1100 volts grade. Note:- (i) Foundation drawings need to be provided by OEM/contractor for transformer and need to be approved from accepting officer and Engr-in-charge. (ii) Factory testing costing deemed to be included in quoted rate. Factory testing should be carried out in presence of representative of accepting officer along with Engr-in-charge. | |||||||||
| 2.00 | Supplying, laying, testing and commissioning of HT XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) 185 sqmm 3 core with multi stranded aluminium conductors, IS 7098 marked, suitable for HT 11 KV(E) system, laid in trenches / ducts / encased in DWC pipe including jointing & testing complete all as specified and directed by Engr-in-charge.
Note :- (i) Excavation, earth work ,cable protection, DWC pipe, cable joint shall be measured and paid separately under respective items of schedule.
(ii) The contractor will be responsible for taking permission from appropriate authority i.e. NHAI / IGL or other Units, if needed, for above said work.
(iii) The cost quoted is deemed to be included for repairs / rectification for damages done to the existing electrical / communication / water supply system / Sewage System during execution of work. | 1,000 | RM | 1,721 ₹17,21,000 | 1,780 ₹17,80,000 | 1,505 ₹15,05,000 | 1,589 ₹15,89,000 | 1,706 ₹17,06,000 | 1,299 ₹12,99,000 Lowest |
| 3.00 | Supplying, laying, testing and commissioning of LT XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) 400 sqmm single core with multi stranded aluminium conductors, IS 7098 marked, suitable for LT 1.1 KV system, laid in trenches / ducts / encased in DWC pipe including jointing & testing complete all as specified and directed by Engr-in-charge.
Note :- (i) Excavation, earth work ,cable protection, DWC pipe, cable joint shall be measured and paid separately under respective items of schedule. (ii) The contractor will be responsible for taking permission from appropriate authority i.e. NHAI / IGL or other Units , if needed, for above said work.
(iii) The cost quoted is deemed to be included for repairs / rectification for damages done to the existing electrical / communication / water supply system / Sewage System during execution of work | 100 | RM | 949 ₹94,900 | 1,170 ₹1,17,000 | 650 ₹65,000 | 650 ₹65,000 | 600 ₹60,000 | 499 ₹49,900 Lowest |
| 4.00 | Supply and fixing of cable end jointing kit in 11 KV grade cable for outdoor terminal heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Aluminium conductor cable of size 185 sqmm complete all as specified & directed by Engr-in-charge. | 4 | Each | 2,990 ₹11,960 | 4,000 ₹16,000 | 1,500 ₹6,000 Lowest | 5,000 ₹20,000 | 2,500 ₹10,000 | 4,999 ₹19,996 |
| 5.00 | Supply and fixing of cable jointing kit in 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 185 sqmm complete all as specified & directed by Engr-in-charge. | 1 | Each | 5,500 ₹5,500 | 7,000 ₹7,000 | 4,500 ₹4,500 Lowest | 9,000 ₹9,000 | 8,000 ₹8,000 | 4,999 ₹4,999 |
| 6.00 | Supply, installation, testing and commissioning of LT panel board outdoor type stainless steel (SS 316) Design verified as per IS/IEC-61439-1&2 by CPRI approved manufacturers along with FAT floor mounted 500V AC 3 Phase , 50 Hz factory made outdoor type, floor mounted double front execution, made out of 3.15 mm thick SS 316 and inner compartment should be 2 mm with arrangement for bus trunking entry from top of the panel with lifting angle 50x50x6mm base of 450mm height. Cable of size upto 400 sqmm single core seven run entry/out from bottom confirming to degree of protection IP-65 ,gasketing of PU foam gasket ensuring IP protection for temperature with stand by capacity 40 to 80 degree celsius with power coating and locking arrangements. LT panel mounted on 02 Nos, PCC/RCC pillars including excavation and earth work (PCC 1:2:4) type B1
The LT Panel should be pre-wired proper spacing to accommodate all accessories, cable connection with suitable size of lugs /thimbles and cable glands comprising of the following
(a) Aluminium bus bar 3 phase and neutral 800 Amps ,415 volts, fixed horizontally, duly insulated with heat shrinkable sleeves in colour code - 01 Set.
(Incoming) (i) ACB with manual drawout with microprocessor release type 4 pole 630Amps, 50 Hz with ultimate breaking capacity Icu 50 KA at 415 volt - 01 No.. (Outgoing) (i) MCCB adjustable type 4 pole 250Amps, 50 Hz with ultimate breaking capacity Icu 36 KA at 415 volt - 02 Nos (ii) MCCB 4 pole,415V adjustable type,200 Amps with breakhing capacity 36KA -02 Nos (b) Multifunction meter with communication ports RS 485/232, 5 display, class-1. - 01 set (c) Indication lamps R,Y,B LED type
Note:-
(a) Cost of PCC/RCC works for placing LT panel on plinth is deemed to be included in the quoted Rate. Height of plinth should not be less than 0.45 mtrs from ground level. Suitable openings for cable entry and provisions for earthing shall be incorporated, and the top surface shall be finished smooth and level to accomodate the panel. | 1 | Each Job | 3,19,000 ₹3,19,000 Lowest | 5,05,000 ₹5,05,000 | 4,35,000 ₹4,35,000 | 4,89,000 ₹4,89,000 | 5,25,662 ₹5,25,662 | 4,99,999 ₹4,99,999 |
| 7.00 | M&L for earthing for transformer complete with galvanized steel earth plate electrode of size 60cmx60cmx6 mm thick, buried directly in ground (earth pit not less than 2.5 m below normal ground level) with top edge of earth plate not less than 2.5m below normal ground level, connected to galvanized iron strip 25X4 mm by means of electric arc welding of galvanised iron or steel as shown in electrical plate No 3 of SSR Part I, connected to earth test point and the equipment on the other side complete including testing and commissioning complete all as specified and directed by Engr-in-charge.
Note : (a) The unit rates quoted against this item shall be deemed to include the cost of excavation and earth work in any type of soil, common salt & charcoal dust in alternate layers, PCC 1:3:6 as in pit, precast RCC 1:2:4 type B-1 with necessary reinforcement as in cover & frame for pit, funnel, watering pipe 20 mm bore GI pipe light grade, protection pipe 40 mm bore GI pipe light grade etc.
(b) The quoted rates shall also deemed to include earth strip/GI earthing and protection pipe upto 7.5 meter beyond the earth plates electrode or upto the test terminal block. | 4 | Each | 4,900 ₹19,600 | 3,000 ₹12,000 | 2,500 ₹10,000 Lowest | 4,500 ₹18,000 | 3,500 ₹14,000 | 9,999 ₹39,996 |
| 8.00 | M&L for earthing complete with copper earth plate electrode of size 60cmx60cmx3.15 mm thick, buried directly in ground (earth pit not less than 2.5 m below normal ground level) with top edge of earth plate not less than 1.5m below normal ground level, connected to copper strip 20 X 3 mm by means of electric arc welding / brazing as shown in electrical plate No 3 of SSR Part I, connected to earth test point and the equipment on the other side complete, including testing and commissioning complete all as specified and directed by the Engr-in-Charge.
Note : (a) The unit rates quoted against this item shall be deemed to include the cost of excavation and earth work in any type of soil, common salt & charcoal dust in alternate layers, PCC 1:3:6 as in pit, precast PCC 1:2:4 type B-1 with necessary reinforcement as in cover & frame for pit, funnel, watering pipe 20 mm bore GI pipe light grade, protection pipe 40 mm bore GI pipe light grade etc.
(b) The quoted rates shall also deemed to include the earth strip and protection pipe upto 7.5 meter beyond the earth plates electrode or up to the test terminal block. | 2 | Each | 19,900 ₹39,800 | 14,000 ₹28,000 Lowest | 33,000 ₹66,000 | 16,000 ₹32,000 | 30,000 ₹60,000 | 14,999 ₹29,998 |
| 9.00 | Supply and fixing of Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw complete all as specified and directed by the Engr-in-Charge. | 6 | Each | 699 ₹4,194 | 700 ₹4,200 | 500 ₹3,000 | 600 ₹3,600 | 1,500 ₹9,000 | 499 ₹2,994 Lowest |
Tender Value
₹44.5 L
EMD Value
₹89,000
Closing Date
12 Aug 2026, 6:00 pmClosed
GE Utility Electric Supply
GE Utility Electric Supply DELHI CANTT-10
PROVN OF EXTERNAL ELECTRIC SUPPLY FOR OFFICE SPACE DNI6 AT NAU SENA BHAWAN UNDER GE U E S DELHI CANTT
2026_MES_778685_1
GE ELECT/TOKEN-16/2026-2027
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE Utility Electric Supply
AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
GE Utility Electric Supply
₹89,000
18 Aug 2026
15 Jul 2026
14 Aug 2026
15 Jul 2026
12 Aug 2026
29 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply, installation, testing and commissioning of transformer step down, outdoor type copper wound Level-III ,IS 1180, 11KV/433 Volts (at no load) AC 3 phase 50 Hz 400 KVA capacity, core type, oil immersed naturally cooled, oil natural air natural (ON/AN), with external cooling tubes, delta connected on primary side (HT) and star connected on secondary side (LT) in accordance with vector group DYn-11 with neutral brought out on secondry side (LT) and having taping at ±10% in steps of 2.5% on HT side to be changed by means of hand operated off load tap changer. The maximum temperature rise should not exceed 40 degree celsius in oil and 45 degree celsius in HT/LT winding when measured by resistance method after continuous full load run on an ambient temp of 40 degree celsius transformer shall be of BOLTLESS core design. Transformer shall be double wound, core type with low loss, non ageing, high permeability prime grade crgo with M4 grade or better, perfectly insulated and clamped to minimize noise and vibrations. The transformer shall be IS/IEC 60076and as per IS-1180 part - I of 2014 marked, Including the cost of PCC/RCC foundation including necessary framework & fencing in perimeter location for placing of TRANSFORMER complete all as per IE/IS specification and shall comprise of the following :- | 1 | Each | - | - |
| 1.1 | (a) One cable box on HT side (Primary side) consisting of three nos porcelain bushing with copper rods, complete with nuts and washer with cable glands suitable for reception / taking out 3 core 185 Sqmm, HT 11000 volts grade, XLPE insulated and PVC sheathed, heavy duty , armoured cables including jointing materials complete.
(b) One cable box on LT side(secondary side) consisting of four nos porcelain bushing with copper rods,for connected bus ducts complete with nuts and washers, with cable glands suitable for reception / taking out single core 400 sqmm, LT 1100 volts grade, XLPE insulated and PVC sheathed, heavy duty, armoured cables including jointing materials complete.
(c ) Conservator with filter type drain valve and oil level guage.
(d) De-hydrating breather with first fill of dehydrating agent (Silica Gel).
(e) Explosive vent, Thermometer pocket on tank cover, oil level guage, Oil drain filter valve, Lifting lugs,oil filling hole with cap/plug with connection plate complete, Air release valve plug and four nos plain solid cast steel detachable rollers.
(f) One no 100 mm dia, dial type thermometer, vapour pressure type, having range 0-120 degree celsius with metal guard having maximum perimeter temperature reading indicator with re-setting device.
(g) Two earthing terminals on tank cover to facilitate fixing of 50x6mm galvanised iron earth strip for earthing of body.
(h) Rating plate and terminal marking plate.
(j) Extra bushing for neutral in the LT cable box for providing independent set of earthing for neutral.
(k) First fill of new and unused transformer oil, IS-335 marked, filtered and tested upto 40 KV dielectric strength at 2.5 mm air gap between testing electrodes.
(l) Providing adequate size and nos of channels, embeded in floor, for movement of transformer.
(m) Tranformer losses shall not exceed the loses mentioned in IS: 1180(2014) Part - I with energy Efficiency level - III.
(n) Oil temperator indicator , winding temperature indicator, marshalling box single window, double flit buchholz relay with alarm and trip contact including connection to existing RMU relay with PVC insulated PVC sheathed cable galvanized steel strip or wire armoured electric control cables (Heavy duty) with stranded copper conductor of size 1.5 sq mm 10 core 1100 volts grade.
Note:-
(i) Foundation drawings need to be provided by OEM/contractor for transformer and need to be approved from accepting officer and Engr-in-charge.
(ii) Factory testing costing deemed to be included in quoted rate. Factory testing should be carried out in presence of representative of accepting officer along with Engr-in-charge. | - | - | - | - |
| - | Supplying, laying, testing and commissioning of HT XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) 185 sqmm 3 core with multi stranded aluminium conductors, IS 7098 marked, suitable for HT 11 KV(E) system, laid in trenches / ducts / encased in DWC pipe including jointing & testing complete all as specified and directed by Engr-in-charge.
Note :- (i) Excavation, earth work ,cable protection, DWC pipe, cable joint shall be measured and paid separately under respective items of schedule.
(ii) The contractor will be responsible for taking permission from appropriate authority i.e. NHAI / IGL or other Units, if needed, for above said work.
(iii) The cost quoted is deemed to be included for repairs / rectification for damages done to the existing electrical / communication / water supply system / Sewage System during execution of work. | 1,000 | RM | - | - |
| - | Supplying, laying, testing and commissioning of LT XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) 400 sqmm single core with multi stranded aluminium conductors, IS 7098 marked, suitable for LT 1.1 KV system, laid in trenches / ducts / encased in DWC pipe including jointing & testing complete all as specified and directed by Engr-in-charge.
Note :- (i) Excavation, earth work ,cable protection, DWC pipe, cable joint shall be measured and paid separately under respective items of schedule. (ii) The contractor will be responsible for taking permission from appropriate authority i.e. NHAI / IGL or other Units , if needed, for above said work.
(iii) The cost quoted is deemed to be included for repairs / rectification for damages done to the existing electrical / communication / water supply system / Sewage System during execution of work | 100 | RM | - | - |
| - | Supply and fixing of cable end jointing kit in 11 KV grade cable for outdoor terminal heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Aluminium conductor cable of size 185 sqmm complete all as specified & directed by Engr-in-charge. | 4 | Each | - | - |
| - | Supply and fixing of cable jointing kit in 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 185 sqmm complete all as specified & directed by Engr-in-charge. | 1 | Each | - | - |
| - | Supply, installation, testing and commissioning of LT panel board outdoor type stainless steel (SS 316) Design verified as per IS/IEC-61439-1&2 by CPRI approved manufacturers along with FAT floor mounted 500V AC 3 Phase , 50 Hz factory made outdoor type, floor mounted double front execution, made out of 3.15 mm thick SS 316 and inner compartment should be 2 mm with arrangement for bus trunking entry from top of the panel with lifting angle 50x50x6mm base of 450mm height. Cable of size upto 400 sqmm single core seven run entry/out from bottom confirming to degree of protection IP-65 ,gasketing of PU foam gasket ensuring IP protection for temperature with stand by capacity 40 to 80 degree celsius with power coating and locking arrangements. LT panel mounted on 02 Nos, PCC/RCC pillars including excavation and earth work (PCC 1:2:4) type B1
The LT Panel should be pre-wired proper spacing to accommodate all accessories, cable connection with suitable size of lugs /thimbles and cable glands comprising of the following
(a) Aluminium bus bar 3 phase and neutral 800 Amps ,415 volts, fixed horizontally, duly insulated with heat shrinkable sleeves in colour code - 01 Set.
(Incoming) (i) ACB with manual drawout with microprocessor release type 4 pole 630Amps, 50 Hz with ultimate breaking capacity Icu 50 KA at 415 volt - 01 No.. (Outgoing) (i) MCCB adjustable type 4 pole 250Amps, 50 Hz with ultimate breaking capacity Icu 36 KA at 415 volt - 02 Nos (ii) MCCB 4 pole,415V adjustable type,200 Amps with breakhing capacity 36KA -02 Nos (b) Multifunction meter with communication ports RS 485/232, 5 display, class-1. - 01 set (c) Indication lamps R,Y,B LED type
Note:-
(a) Cost of PCC/RCC works for placing LT panel on plinth is deemed to be included in the quoted Rate. Height of plinth should not be less than 0.45 mtrs from ground level. Suitable openings for cable entry and provisions for earthing shall be incorporated, and the top surface shall be finished smooth and level to accomodate the panel. | 1 | Each Job | - | - |
| - | M&L for earthing for transformer complete with galvanized steel earth plate electrode of size 60cmx60cmx6 mm thick, buried directly in ground (earth pit not less than 2.5 m below normal ground level) with top edge of earth plate not less than 2.5m below normal ground level, connected to galvanized iron strip 25X4 mm by means of electric arc welding of galvanised iron or steel as shown in electrical plate No 3 of SSR Part I, connected to earth test point and the equipment on the other side complete including testing and commissioning complete all as specified and directed by Engr-in-charge.
Note : (a) The unit rates quoted against this item shall be deemed to include the cost of excavation and earth work in any type of soil, common salt & charcoal dust in alternate layers, PCC 1:3:6 as in pit, precast RCC 1:2:4 type B-1 with necessary reinforcement as in cover & frame for pit, funnel, watering pipe 20 mm bore GI pipe light grade, protection pipe 40 mm bore GI pipe light grade etc.
(b) The quoted rates shall also deemed to include earth strip/GI earthing and protection pipe upto 7.5 meter beyond the earth plates electrode or upto the test terminal block. | 4 | Each | - | - |
| - | M&L for earthing complete with copper earth plate electrode of size 60cmx60cmx3.15 mm thick, buried directly in ground (earth pit not less than 2.5 m below normal ground level) with top edge of earth plate not less than 1.5m below normal ground level, connected to copper strip 20 X 3 mm by means of electric arc welding / brazing as shown in electrical plate No 3 of SSR Part I, connected to earth test point and the equipment on the other side complete, including testing and commissioning complete all as specified and directed by the Engr-in-Charge.
Note : (a) The unit rates quoted against this item shall be deemed to include the cost of excavation and earth work in any type of soil, common salt & charcoal dust in alternate layers, PCC 1:3:6 as in pit, precast PCC 1:2:4 type B-1 with necessary reinforcement as in cover & frame for pit, funnel, watering pipe 20 mm bore GI pipe light grade, protection pipe 40 mm bore GI pipe light grade etc.
(b) The quoted rates shall also deemed to include the earth strip and protection pipe upto 7.5 meter beyond the earth plates electrode or up to the test terminal block. | 2 | Each | - | - |
| - | Supply and fixing of Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw complete all as specified and directed by the Engr-in-Charge. | 6 | Each | - | - |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.42 MB
TD16.pdf
Tender Documents • 1.25 MB
BOQ_872153.xls
BOQ • 0.26 MB
AmendNO1t16.pdf
PDF • 0.59 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .