Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance RZ M 21 NAND BLOCK MAHAVIR ENCLAVE PALAM NEW DELHI 110045 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110045 | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
| 5 | Admitted-Finance | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹40,767
Closing Date
25 Jul 2023, 12:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EXECUTIVE ENGINEER (ELECTRICAL)
BSNL ELECTRICAL DIVISION-I, EASTERN COURT, JANPATH, NEW DELHI-110001
Operation and all inclusive comprehensive maintenance of various Electromechanical Services at BSNL Holiday Home Kashmere Gate, New Delhi
2023_BSNL_158795_1
11/NIT/E-Tender/2023-24/ED-I
Open Tender
Electrical Works
Item Rate
730 days
NEW DELHI
Please refer Tender documents.
4 documents required · 4 mandatory
₹590
AO (CASH), O/O CGM, BSNL, NTR, NEW DELHI
₹40,767
31 Jul 2023
24 Jun 2023
28 Jul 2023
24 Jun 2023
25 Jul 2023
24 Jun 2023
Operation and all inclusive Comprehensive maintenance of various Electro-mechanical services as per details & inventory given in relevant sections by deploying the required staff to keep all the services operational up to the required standards etc. complete as per specification. The services are: 1. Diesel Engine Alternator sets 2. Split AC Units 3. Electrical Installation & fans 4. Water Cooler 5. R.O. System 6. Compound Lights 7. Automatic Fire Detection & Alarm system 8. LAN system 9. Fire Extinguishers & Fire Buckets Etc. Staff Required (Must be less than 55 Years age) Round the Clock General /Shift duty Semi-Skilled Un- skilled Semi-Skilled Un-Skilled 1 No. 0 No. 0 No. 0 No. NOTE: - This is tentative list, however it is the responsibility of the agency to operate and maintain various services such as availability of water etc. as & when required even during odd / night hours as per requirements of BSNL & if any additional labour is required the same is to be provided at no extra cost.
Servicing of 100 KVA capacity Diesel Engine Alternator Set through OEM/ Authorized dealers as per manufacturer recommendations including replacement of engine oil and filter cartridges, top up of coolant, Cleaning of air filter, Checking of V-belt, drive and tightness of nuts & bolts, Checking of air and water hose piping, Checking of engine safety fuel pump, Engine protection devices and battery, properly tightening of all mounting fasteners including Recording engine parameters before and after servicing etc. complete as required.
Replacement of existing faulty 12 Volts maintenance free Battery of Diesel Engine Alternator Set and Fire Detection system with new battery of same capacity including making connections, replacement of new battery terminals, testing etc. complete as required. (Note: The faulty battery shall be the property of firm and rate should be quoted accordingly).
Overhauling and servicing of ceiling fan/exhaust fan including disconnection & dismantling, cleaning, replacing worn out parts like bearing, quarter pin, lock nuts, rubber bush, refixing, etc. complete as required.
Servicing of Geyser of 15/20/25 ltrs. Capacity, 2000 watts, vertical mounting, 230V single phase, 50 Hz AC supply metal body i/c dismantling, checking of faulty parts, cleaning of rust/foreign particles etc., reinstallation, connections, testing etc. complete as required.
Replacement of all the filters suitable for the existing Water Filtration RO treatment system as per requirement & specification i/c dismantling of existing outlived/ faulty filters, supply of new filters etc. complete as required in all respect to the entire satisfaction of Engineer-in-charge.
Servicing of 1.5/2 TR capacity Split AC / water cooler Units including washing & cleaning of filters, evaporator unit, condenser unit including oiling, greasing of motors, testing, commissioning etc. complete as reqd.
Making arrangement for the Measurement & Testing of earth resistance of the existing earthing system etc. complete as required.
Painting one or more coats on old work with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade i/c removing dust, grease, rust, cleaning the surface with abrasive material etc. complete as required.
Refilling/Recharging of existing following different type & capacity fire extinguishers, reinstallation at its proper place etc. complete as required
CO2 Type – 4.5 Kgs.
ABC Powder Type – 5 Kgs.
Replacement/SITC of Energy Efficient Ultra modern 595mm x 595mm size LED luminaire having following specifications i/c dismantling of existing outlived/ faulty conventional luminaire with high brightness SMD LEDs, making suitable arrangement for installation etc. complete as reqd in all respect to the entire satisfaction of Engineer-in-charge:- a) Wattage : 36 Watt + 10% b) System lumens efficacy : Not less than 100 lumen per watt c) Driver efficiency : Not less than 85% d) THD : Not more than 10% e) CRI : Not less than 80 f) UGR : Less than 19% g) LED Life : Not less than 50000 hours @ LM 70% h) Colour temperature : 5500 - 6500 K i) Operating voltage range : 140 Volt to 270 Volt j) Installation type : Recess Ceiling installation K) Material of construction for housing : CRCA powder coated white after phosphochromate treatment l) Material of construction for cover : Scratch resistant and polycarbonate diffuser / cover m) Electronic Driver : independent Isolated type (Constant current supply) n) Internal surge protection : Not less than 2.5 kV o) Ingress protection (IP) : Not less than 20 (Make: M/S Havells/Philips/Wipro)
Replacement/SITC of Energy Efficient Ultra modern bright 20W, 1200 mm Long LED Polycarbonate tube light (Single Side Connection) having following specifications i/c dismantling of existing outlived/ faulty conventional tube lights from existing fitting etc. complete as required: a) Wattage : 20 Watt + 10% b) System lumens efficacy : Not less than 110 lumen per watt c) Driver efficiency : Not less than 85% d) THD : Not more than 10% e) CRI : Not less than 80 f) LED Life : Not less than 50000 hours @ LM 70% g) Colour temperature : 5500 - 6500 K h) Operating voltage range : 160 Volt to 270 Volt i) Installation type : Wall / Ceiling surface installation j) Material of construction for housing : Polyuminum die cast k) Internal surge protection : Not less than 2.5 kV l) Ingress protection (IP): Not less than 20. (Make: M/S Havells/Philips/Wipro)
Replacement/SITC of Energy Efficient Ultra modern bright 20 W, LED batten directly on surface having following specifications i/c dismantling of existing outlived/ faulty fitting etc. complete as required : a) Wattage : 20 Watt + 10% b) System lumens efficacy : Not less than 110 lumen per watt c) Driver efficiency : Not less than 85% d) THD : Not more than 10% e) CRI : Not less than 80 f) LED Life : Not less than 50000 hours @ LM 70% g) Colour temperature : 5500 - 6500 K h) Operating voltage range : 160 Volt to 270 Volt i) Installation type : Wall / Ceiling surface installation j) Material of construction for housing : Polyuminum die cast k) Internal surge protection : Not less than 2.5 kV l) Ingress protection (IP): Not less than 20. (Make: M/S Havells/Philips/Wipro)
Replacement of existing faulty/unseriviceable 1.5 TR Indoor Units of Split AC Units by supplying new 1.5 TR Indoor Unit, suitable for operation on 230 V AC supply, complete with blower, cooling coil, filters, controls & all accessories and remote control, etc. complete as reqd. (Make : M/S Hitachi/ Blue Star/Carrier/Voltas or Similar Superior make)
Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for AC Units system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc. as required :
6.4 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation
15.86 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation
Replacement/ fixing of 6 Amp 4 outlet power strip controlled by common switch with surge protection suitable for 230 Volts, 50 Hz Single phase AC supply having connecting lead, safety fuse etc. complete as reqd. (Make: M/S Havells/ Anchor/ Philips)
Note: 1. The Agency has to submit police verification record & ID proof of each operator. 2. The firm shall provide each operator with working cell phone. 3. The operators may be deputed for duty as per instruction of concerned SDE (E)/JTO (E). 4. Prior approval of Sr. CE (E) is required for deviation. 5. Penalty shall be imposed in case of absence of any operator as per T & C of contract. 6. The GST / other Input Tax Credit (ITC) taxes shall be quoted by the firm as applicable as per latest amendments of GST Rules. 7. The contractor shall provide correct tariff heads & other details to enable BSNL claim Input Tax Credit. 8. Servicing Scrap items will be credited to the firm. The rate may be quoted accordingly. 9. Bidder must mandatorily quote for all GST components (CGST, SGST, and IGST) as required. 10. If annual maintenance contract charges are required to be quoted as per SOW, basic charges should be shown in column 4 & the Goods and Service Tax (GST) in column 7 to 12. 11. The bidder who submits the offer with concessional Goods and Service Tax (GST) shall submit the proof of applicable concessional GST. In case the Concessional GST is not creditable to BSNL it should be included in the price of the goods/services. 12. In case, dealer is registered under compounding scheme or any rule/notification where the BSNL is not eligible for input tax credit then the bidder should not disclose any amount in column 7 to12 & 14. 13. % age Rate of FF & Packing should be shown of basic unit price excluding all taxes & charges (i.e. as %age of col.4). 14. The FF & packing amount quoted shall not be subject to change after bid evaluation /ordering on account of change of copper, lead base price, change in duties & taxes of item etc. 15. Bidder must mandatorily mention HSN & SAC numbers. 16. Evaluation of bids: - The evaluation and comparison of responsive bids shall be done on the basis of Net cost to BSNL on the prices of the goods & Services (i.e. complete work) offered along with all applicable Taxes, packing Forwarding Freight & Insurance charges etc. exclusive of GST. Declaration by Bidder 1. We hereby declare that in quoting the above prices, we have taken into account the entire credit on inputs available under the GST Act introduced w.e.f. 1 July 2017 and further extended on more items till date. 2. We hereby certify that HSN/SAC shown in column 17 are correct & credit of GST for the amount shown in column 14 above are admissible as per GST Laws. Name of bidder: Seal of Company: GST No./(s)
STAR ELECTRIC WORKS
Mahajan Sales Corporation
SS ASSOCIATES
PRATEEK ELECTRICALS & EQUIPMENTS
JAI SAI ENGINEERING
M/s ROHIT ENTERPRISES
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .