Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.7 LAccepted-AOC H NO 37 VIKAS VIHAR PHASE II FEROZEPUR CITY PB 152002 | FEROZEPUR CITY | FEROZEPUR | PUNJAB | 152002 | L1 | Accepted-AOC Reasonable lowest tenderer | |
| 2 | L2₹24.4 L+₹54,648.06 (2.29%)Rejected-Finance | L2 | Rejected-Finance Not Lowest tenderer | |
| 3 | L3₹24.9 L+₹1.0 L (4.19%)Rejected-Finance SUMEL BAMANWAS SWAI MADHOPUR | L3 | Rejected-Finance Not Lowest tenderer | |
| 4 | L4₹25.7 L+₹1.8 L (7.59%)Rejected-Finance | L4 | Rejected-Finance Not Lowest tenderer | |
| 5 | L5₹26.0 L+₹2.1 L (9.00%)Rejected-Finance | L5 | Rejected-Finance Not Lowest tenderer |
Tender Value
₹50 L
EMD Value
₹1 L
Closing Date
18 Oct 2023, 6:00 pmClosed
GE (East) Ferozepur Cantt
GE (East) Ferozepur Cantt
Repair/ Replacement of DB MCB, Sub Main fitting, Bldg Security lights and Internal wiring of Md Accn and OTM Accn under GE (East) Ferozepur Cantt
2023_MES_620217_1
8149/GE/E/FZR/23-24/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (East) Ferozepur Cantt
Please refer Tender Documents
8 documents required · 8 mandatory
₹500
Yes
GE (East) Ferozepur Cantt
₹1 L
Yes
13 Dec 2023
22 Sept 2023
20 Oct 2023
22 Sept 2023
18 Oct 2023
6 Oct 2023
Amount
Taking down carefully existig copper/ alumn point wiring for light/ fan/ bell/ socket 5/15 Amp points complete with fitting and fixtures such as Switches, Sockets, Ceiling Rose, Lamp Holder and bracket fittings with Battens/ Conduits/ Wires and making good the disturbed surfaces of walls and roofs etc to match with existing surface complete all as specified and directed.
Taking down carefully unserviceable main switches and distribution boards (single phase or three phase) of any capacity with Isolators/ MCBs/ MCCBs complete all as specified and directed.
Taking down carefully old unserviceable sub main wiring and making good disturbed surfaces and matching with existing complete all as directed and specified
M&L Point wiring complete with 1100 volts grade PVC FRLS insulated unsheathed cable of copper conductor, multi stranded of size 1.5 Sqmm, single core, drawn through & including new PVC rigid concealed conduit, medium grade of suitable size (not less than 20mm dia) duly ISI marked with all accessories such as bends, reducers, spacers, saddles, junction boxes, bakelite sheets and various sizes hylam sheets for mounting switch/ sockets, fan regulators etc complete with and including continuous earth wire of size 1.5 Sqmm, single core, PVC FRLS copper conductor, insulated, unsheathed, stranded (Green colour) connected to common earth dolly complete all as specified for following :- (a) One light/ fan/ bell/ Bldg security light point controlled by one single pole one way switch.
All as per item No. 04 as above but one 3 pin, 5 Amp, socket outlet on the independet board controlled by one single pole one way switch board complete all as specified and directed.
All as per item No. 04 as above but one 3 pin, 5 Amp, socket outlet on the same board controlled by one single pole one way switch board complete all as specified and directed.
All as per item No. 04 as above here-in-before but wiring with 2.5 sqmm copper cable and 2.5 Sqmm copper cable as continuous earth wire for one 6 pin 6/16 Amps socket out let on independent board complete all as specified and directed.
All as per item No. 07 as above here-in-before but wiring with 4 sqmm copper cable and 4 Sqmm copper cable as continuous earth wire for one 6 pin 6/16 Amps socket out let on independent board complete all as specified and directed.
All as per item No 04 above but existing conduit and existing Ms pressed steel/ cast iron box complete all as speicifed and directed.(a) One light point/fan/bell point controlled by one single pole one way switch.
All as per item No - 05 above but existing conduit and existing Ms pressed steel/ cast iron box complete all as specifed and directed.
All as per item No - 07 above but existing conduit and existing Ms pressed steel/ cast iron box complete all as specifed and directed.
S&F switch piano flush type, 5 Amp, single pole, one way, 240 volts complete all as specified and directed.
S&F Bell push switch piano flush type, 5 Amp, single pole, one way, 240 volts complete all as specified and directed.
S&F Switch piano flush type, 15 Amp, single pole, one way, 240 volts complete all as specified and directed.
S&F socket outlet flush type 2-in-1, multipupose, 3 pin 5 Amp and 2 pin 5 Amp complete all as specified and directed.
S&F socket outlet flush type 2-in-1, multipurpose, 3 pin 5 Amp and 3 pin 15 Amp, 240 volts complete all as specified and directed.
S&F ceiling rose surface bakelite 3 terminals 65 x 50mm complete all as specified and directed.
S&F batten holder insulated body suitable LED lamp 10W 220-240 volts, 6500K, B-22 base cap complete all as specified and directed.
S&F electronic ceiling fan regulator stepped type heavy duty 120W, 250 volts flush type complete all as specified and directed.
S & F in repair Modular Switch one way 6 A, 1 module complete all as per specified and directed.
S&F Modular Bell push 6 Amps, one module, 240 volts complete all as specified and directed.
S & F in repair Modular Switch one way 16 A, 1 module complete all as per specified and directed.
S & F in repair Modular Socket, 6A - 2/3 pin combined 2 module complete all as per specified and directed.
S & F in repair Modular Socket, 6A/16A - 2/3 pin combined 2 module complete all asper specified and directed.
S&F Modular ceiling fan regulator electronic stepped type heavy duty 120W, 250 volts flush type complete all as specified and directed.
S & F in repair Modular white cover plate including GI box inner, 3 module complete all as per specified & directed.
S & F in repair Modular white cover plate including GI box inner, 4 modulecomplete all as per specified & directed.
S & F in repair Modular white cover plate including GI box inner, 8 module complete all as per specified &directed.
S&F 20W, 6500K, 4 feet LED tube light fitting, energy efficient, 240 volts, fixed on wall/ ceiling etc including connecting up with twin core twisted flexible copper conductor cable with suitable size all as specified and directed.
S&F LED bulb of 9 watt, B22 base, 6500K all as specified and directed.
Supply & Fix in repair LED tube/mirror light fitting 9 watts, 2 feet batten type fixed on wall/ ceiling etc. including connecting up with twin core twisted flexible copper conductor cable with suitable size all as specified and directed.
S&F Door Bell Ding Dong single phase 240 volts, white in colour, duly ISI marked complete all as specified and directed..
S&F LED sleeky bldg security light (Lens) fitting of 35 watts, 6000K, including GI bracket bend to shape made out of GI pipe light grade of 25 mm, size up to 1.2 mtr long etc complete with two nos of bolts of suitable size, duly painted with two coats of synthetic enameled paint and all fixing arrangements to wall/ pole, including connecting up with 2 core copper flexible wire of size 23/00.0076 all as specified and directed.
S&F Factory made sheet metal enclosures double door type made out of CRCA 1.2 mm thick M.S. sheet, powder coated, partly embedded in wall, IP-43 protection, VTPN DB with 200 Amps rated bus bar, 4 way, 415 volts, vertical type, dust and vermin proof, suitable for incorporation of MCCBs/ MCBs, factory made, including thermal based release adjustable type 4 pole 100 Amps, 50 Hz, 415 Volts with rupturing capacity 16 KA and making good distrubbed surfaces with matching colour, complete all as specified. Note: VTPN is including MCCB and rate of MCCB 100 Amps is included in the rates quoted agaist this item.
S&F Factory made sheet metal enclosures double door type made out of CRCA 1.2 mm thick M.S sheet, powder coated, SPN DB with 200 Amps rated bus bar, 8 way, IP-43 protection surface mounting, 240 volts, dust and vermin proof, suitable for incorporation of MCBs duly partially immersed in wall, factory made, including making good distrubbed surfaces with matching colour, complete all as specified.
S&F MCCB thermal based release adjustable type 4 pole 100 Amps 50 Hz 415 Volts with rupturing capacity 16 KA including testing, complete all as specified and as directed.
S&F MCB SPN, 40A-60A, 240 volts, "C" series, 10KA duly ISI marked, complete all as specified.
S&F MCB SP, 6A-32 Amps, 240 volts, "B" series, 10KA duly ISI marked, complete all as specified.
S&F Sub main wiring with two single core 2x6 sqmm PVC insulated and unsheathed stranded copper conductor alongwith earth wire 6 sqmm drawn in 25 sqmm PVC rigid conduit connected to main board complete all as specified and directed. (Two number cable and one number earth wire shall measured together as unit length).
Supply & fixing in repair 1.5 Sqmm (Nominal area) FRLS PVC insulated and unsheathed single core cable 1100 Volts grade with stranded copper conductor complete all as per specified & directed.
Supply & fixing in repair 2.5 Sqmm (Nominal area) FRLS PVC insulated and unsheathed single core cable 1100 Volts grade with stranded copper conductor complete all as per specified & directed.
Suplying and fixing in repair 1100 volts grade heavy duty 10 Sq mm two core cable PVC insulated aluminium Stranded conductor, served with inner shething of PVC sheathed in service conections suspended by insulating hangers and procelean beat not more than I metre apart including 4Sq mm suspension wire, one twin core cable flat or circular of 10 sqmm complete all as specified and directed
Suplying and fixing in repair 1100 volts grade heavy duty 16 Sq mm two core cable PVC insulated aluminium Stranded conductor, served with inner shething of PVC sheathed in service conections suspended by insulating hangers and procelean beat not more than I metre apart including 4Sq mm suspension wire, one twin core cable flat or circular 10 sqmm complete all as specified and directed
S&F XLPE insulated, armoured,1100 volts grade, heavy duty cable of size 25 Sqmm nominal cross section, 4 core, PVC insulated aluminium conductor, served with inner sheathing of galvanized steel wire or tape and over-all PVC sheathed in service connections, laid in trenches, duct, through pipe, in floor, on pole including jointing with double compression copper stain less steel gland at DBs and testing, complete all as specified.
Excavation in trenches in soft/ loose soil not exceeding 1.5 metre wide and not exceeding 1.5 metre deep and not exc 10 Sqm on plan, for laying of cable and getting out, compete all as specified.
M&L Dry and clean fine sand for cable cushioning to underground cable protection, complete all as specified. (Excavation and earth work measured separately). Note- Punned down thickness shall be measured.
S&F Cover to underground cable with one layer of bricks using sub class ‘B’ bricks (old size) laid flat across the cable complete all as specified. (Excavation and earth work measured separately).
Returning, filling in, earth including spreading, leveling watering and well ramming in layers each not exceeding 25cm thick each layer, complete all as specified.
Removal of surplus soil to a distance not exc. 50 metre and depositing where directed at a level not exc. 1.5 metre above the starting point complete all as specified.
S&F Mild steel galvanised pipe, light grade, 40 mm nominal bore for passing of cable, fixed to poles/ walls, laid under floor/ road crossings, complete with and including clamps socket & elbow etc complete all as specified.
Earthing complete with galvanized steel plate elecrode of size 60 cm x 60cm x 6.3 mm thick burried directly in ground vertically to a depth not less than 2.5 mtr below the ground level with top edge of earth plate at a depth not less than 1.5 mtr below ground level. Earth plate surrounded by 15mm thick packed alternative layers of charcoal dust and comman salt, earth lead GI wire of 4mm dia (8 SWG) by means of bolts , nuts, check nuts and washers of galvanised iron with thimbles. The other end of GI earth wire is connected to main switch board and protected by light grade GI pipe of 15 mm bore. provision of 20mm bore light grade GI pipe for watering including GI funnel and wire mesh. Pipe shallbe provided vertically upto top level of earth pit and then taken horrizontally to the earth pit. Cement concrete chamber of PCC ( 1:3:6 ) type C-2using 40 mm graded stone aggregate.The chamber shall be constructed one metre away from edge of earth pit. 50 mm thick pre cast cover of cement conrete (1:2:4) type B-1 using 20 mm graded stone aggregate and MS angle iron 50 x 50 x 6 mm frame including two coats of painting over a red oxide to exposed steel surfaces. excavation in soft / loose soil, returning filling and removal of surplus soil to a distance of 50 mm as directed and shown in Electrical Plate No- 3 of SSR Part-1 (2009).
Supply & fixing in repair Capacitor (ISI Marked) 2.5 mfd complete all as specified and directed by Engr-in-Charge.
S&F in repair PVC casing/caping with accessories of size 20mm. Note : Nickel cadmium screws should be used for fixing of casing caping complete all as specified and directed.
S&F in repair bakelite sheet hylam 3mm thick with white top fixed with cup washers with machine screws on existing switch board with including removing existing switch/ switch sockets/ bell push etc and refixing the same by making slots on new sheet complete all as specified & directed for MS box fo approx size 8" x 5" etc as in reapirs complete all as specified and directed.
All as per item No 54 but of size 11'' x 9"
S&F in repair PVC Shunken Box rectangular block for mounting normal/modular switches ,sockets,fan regulator etc of following sizes. (a) 175mmx110mmx50mm
All as per item No 56 but of size 200 x 150 x 50 mm
Supply and fixing of Decorative, wall mounting light, brushed nickel finish fixture with acrylic diffuser suitable with 9 W LED lamp B22 base complete all as specified and directed. Cat Part No LHFOAJE1TN1I060 of Havells or equivalent in any other make.
Supply & Fixing in replacement Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole 20 Amp MCB of 'C' series complete all as specified and directed by Engr in Charge.
Supply and fixing in repair LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with highefficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete.
Suplying and fixing in repair 1100 volts grade heavy duty 6 Sq mm two core cable PVC insulated aluminium Stranded conductor, served with inner shething of PVC sheathed in service conections suspended by insulating hangers and procelean beat not more than I metre apart including 4Sq mm suspension wire, one twin core cable flat or circular
Supply & fixing in repair Capacitor (ISI Marked) 2.5 mfd complete all as specified and directed by Engr-in-Charge. Make: Havells
S&F in repair PVC casing/caping with accessories of size 20mm. Note : Nickel cadmium screws should be used for fixing of casing caping complete all as specified and directed.
Supply & fixing in repair BUSBAR CHAMBER TPN-Type (Al.Busbar) in sheet metal enclosure having 200A TPN BBC (Al.) with 4 o/g ways & IP 42 Protection complete all as specified and directed by Engr-in-Charge.
Supply & fixing in repair MCB PROTECTED SOCKET (MODULAR AC BOX) 3 Module IN SHEET STEEL / PLASTIC BOX (WITH SP MINI MCB of 'C' series 25 Amps) complete all as specified and directed by Engr-in-Charge.
S&F XLPE insulated, armoured,1100 volts grade, heavy duty cable of size 10 Sqmm nominal cross section, 2 core, PVC insulated aluminium conductor, served with inner sheathing of galvanized steel wire or tape and over-all PVC sheathed in service connections, laid in trenches, duct, through pipe, in floor, on pole including jointing with double compression copper stain less steel gland at DBs and testing, complete all as specified.
M/s Manoj Construction Co.
GS and Co
HAPPY ELECTRICALS
Dee Kay EnterPrises
M/S N Maini Constrution
M/s G N Const. Co.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .