CWE Bikaner
HQ CWE Bikaner at Mil Stn Bikaner
Comprehensive and preventive maintenance of AC Plants at Anant Vijay Auditorium and certain Workshop under GE (N) Bikaner at Mil Stn Bikaner
2021_MES_432679_1
CWE BKN TOKEN NO 57 OF 2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
365 days
BIKANER
All contractors enlisted with MES in Class E and above and category c(i) subject to the remarks with respect to performance in respect of works in hand reflected in Work Load Return
7 documents required · 7 mandatory
₹500
GE North Bikaner
₹49,060
Yes
20 May 2021
24 Mar 2021
21 Apr 2021
24 Mar 2021
19 Apr 2021
7 Apr 2021
24 Mar 2021 - 1 Apr 2021
Amount
M&L for dismantling & re-assembling condenser and evaporator of chiller unit of capacity 2x125 TR AC Plant (Make – Hitachi) and pumping down the Plant to preserve the existing refrigerant (R-134a) and leak testing of Plant by charging of Nitrogen gas in the entire plant and monitoring for 08 hours including leakages, rectification of leakage by brazing and replacement of necessary gaskets packing where required including copper tubes of suitable size, vacuumising the plant by vacuum pump etc complete all as specified and as directed. Note : Nitrogen gas shall deemed to be included in quoted rate of this item.
M&L for dismantling & re-assembling condenser and evaporator of chiller unit of capacity 4x10.2 TR AC Plant (Make – Blue Star) and pumping down the Plant to preserve the existing refrigerant (R-407) and leak testing of Plant by charging of Nitrogen gas in the entire plant and monitoring for 08 hours including leakages, rectification of leakage by brazing and replacement of necessary gaskets packing where required including copper tubes of suitable size, vacuumising the plant by vacuum pump etc complete all as specified and as directed. Note : Nitrogen gas shall deemed to be included in quoted rate of this item.
M&L for dismantling & re-assembling condenser and evaporator of chiller unit of capacity 2x26 TR AC Plant (Make – Blue Star) and pumping down the Plant to preserve the existing refrigerant (R-407) and leak testing of Plant by charging of Nitrogen gas in the entire plant and monitoring for 08 hours including leakages, rectification of leakage by brazing and replacement of necessary gaskets packing where required including copper tubes of suitable size, vacuumising the plant by vacuum pump etc complete all as specified and as directed. Note : Nitrogen gas shall deemed to be included in quoted rate of this item.
Comprehensive preventive & periodical maintenance of Air Conditioning Plant, comprising of screw type water chiller unit, AHU/humidifiers etc of capacity 2 X 125 TR of make - Hitachi & Model - CW125VRF3E installed at AV Auditorium including servicing of AC Plant by authorized company representative (Hitachi) to check and inspect all air release valves, Gas pipe line, cleaning and setting of sensors, checking of control panels, checking of cooling and heating system, inspection of all type of filters for smooth & trouble free functioning of AC Plant complete all as specified and as directed. Note :- Servicing & maintenance of AC plant shall be carried out through authorized service agency of manufacturer (i.e Hitachi). The contractor shall submit documentary proof/evidence in this regard before taking plants under servicing etc.
Comprehensive preventive & periodical maintenance of Air Conditioning Plant, comprising of scroll type chiller unit and AHU/humidifires etc capacity 4 X 10.2 TR of make - Blue Star & Model - WC25-011R2 installed at 288 Fd Wksp including servicing of AC Plant by authorized company representative (Blue Star) to check and inspect all air release valves, Gas pipe line, cleaning and setting of sensors, checking of control panels, checking of cooling and heating system, inspection of all type of filters for smooth & trouble free functioning of AC Plant complete all as specified and as directed. Note :- Servicing & maintenance of AC plant shall be carried out through authorized service agency of manufacturer (i.e Blue Star). The contractor shall submit documentary proof/evidence in this regard before taking plants under servicing etc.
Comprehensive preventive & periodical maintenance of Air Conditioning Plant, comprising of scroll type chiller unit and AHU/humidifires etc capacity 2 X 26 TR of make - Blue Star & Model - WC7.5-011R2 installed at 21 Mahar including servicing of AC Plant by authorized company representative (Blue Star) to check and inspect all air release valves, Gas pipe line, cleaning and setting of sensors, checking of control panels, checking of cooling and heating system, inspection of all type of filters for smooth & trouble free functioning of AC Plant complete all as specified and as directed. Note :- Servicing & maintenance of AC plant shall be carried out through authorized service agency of manufacturer (i.e Blue Star). The contractor shall submit documentary proof/evidence in this regard before taking plants under servicing etc.
Notes aplicable to serial item No. 4.00, 5.00 & 6.00 here-in-before :- (i) Job includes maintenance of AC plant of capacity 2X125 TR, 4X10.2 TR and 2x26 TR in summer, winter and monsoon season as per the period of contract including periodical checks i.e four months maintenance requirement as per manufacturer's instructions. The job covers daily upkeep of AC plant comprising of chiller unit i.e condenser, chiller, etc. complete and cleaning of AHUs with electric motor including pan type humidifiers of different KW ratings, complete ducting, fan coil units, cooling tower, hot water generator and its piping network, chilled water piping, condense piping, pump and motors of chilled water and condenser and cooling towers, water supply piping, instruement starter, connected control cabling/wiring including electrical panels with switchgear (except compressor unit) for smooth & efficient performance of AC plant to achieve desired inside conditions throughout the season all as specified & as directed. (ii) Cleaning of installation inside and out side of the Bldg and the cost thereof shall deemed to be included in the unit rate quoted against this item. (iii) Contractor shall provide Techanically qualified person for fault attending within 24 hrs. If the AC plant is off load/break down more than 24 hrs, a penalty at the rate of Rs. 5000/- per day shall be levied and deducted from the contractor's payment. (iv) Contractor shall maintain temperature of AC plants at 23 ± 2 degree Celcius and RH 50 ± 5%. (v) During entire contract period any defective components/or any other materials which is not specified in Sch 'A' but required repair/replacement to make plant/ machinery fully functional, the cost of same shall be deemed included in quoted rates and nothing extra shall be paid to the contractor on this account. The transportation and other necessary equipments shall be arranged/brought by the contractor, hence the bidder is advised to visit the site and assess the quantum of the work to be carried out in the contract and quote their rate accordingly. (vi) Make and model of part to be replaced shall be same as existing at site or as per OEM. (vii) Comprehensive /Periodic maintenance means ensuring optimal functioning of AC plant by synchronising all levels at no extra cost. (viii) All above points mentioned in notes for the period of four months shall be considered as one Job. (ix) Periodic maintenance shall take place at every four month or as directed by GE/CWE. (x) Each Job shall be measured and paid in four calendar months. (xi) All installations & surrounding area shall be kept neat and clean all the time by the contractor’s workmen and quoted rate shall deemed to include this provision.
Descaling condenser, chiller and hot water circuit of the following unit by company representative using appropriate chemical as per manufacturer's instructions, cleaning the copper tubes with brush, including circulation cleaning chemical by submersible pump and removing all foreign material which are settled inside condenser and chiller unit, with & including replacing the gasket, washers and all materials which are required for descaling, complete all as specified and as directed :-
AC Plant 2X125 TR
AC Plant 4X10.2 TR
AC Plant 2X26 TR
Supply only Refrigerant 'R-134a' for compressor of AC plant of Cap 125 TR for replacement under respective item complete all as specified and as directed.
Supply only Refrigerant 'R-407' for compressor of AC plant of Cap 10.2 and 26 TR for replacement under respective item complete all as specified and as directed.
Supply only compressor oil suitable for screw compressor of AC plant of Cap 125 TR of make as recommended by OEM (i.e Hitachi) for top up / replacement under respective item complete all as directed.
Supply only compressor oil suitable for scroll compressor of AC plant of Cap 10.2 and 26 TR of make as recommended by OEM (i.e Blue Star) for top up / replacement under respective item complete all as directed.
Dismantling, taking out and Material & Labour for rewinding and refixing of electric induction motor with suitable gauge of super enameled copper conductor including winding with fibre cloth/PVC insulated winding paper, superior quality varnishig, servicing of ball bearing, suitable main connections from coil to terminal box, opening of motor, cutting/removing old burnt winding coils, cleaning/filling the starter slots, necessary mechanical works for shaft/bearing housing, preparing and inserting coils running/starting winding, interconnecting, fixing, soldering, jointing, heating, drying up coils, connection and testing at site, satisfactorily running of electric induction motor of capacity 5.5 HP, 3 Phase, 440 Volts, 50 Hz complete all as specified and as directed.
All as per serial item No. 12.00 here-in-before but motor of capacity 7.5 HP, 3 Phase, 440 volts, 50 Hz.
All as per serial item No. 12.00 here-in-before but motor of capacity 12.5/15 HP, 3 Phase, 440 volts, 50 Hz.
M&L for dismantling of centrifugal pump set from its foundation / base frame by disconnecting suction/delivery lines & coupling, opening, including required grinding, welding, machining, lathing, alignment, etc and re-assembling of centrifugal pump set 12.5/15 HP capacity with discharge 15 LPS at 15 Mtr head including replacing worn out spare parts, re-commissioning & testing complete all as specified and as directed. Make - Kirloskar Note : Unserviceable parts required for replacement shall be measured & paid separately as "Supply only" under serial item No. 16.01 to 16.08 here-in-after.
Supply only following spare parts for centrifugal pump of cap 12.5/15 HP with discharge 15 LPS at 15 Mtr head, make - Kirloskar
Pump shaft stainless steel
Impeller brass/bronze complete with impeller key
Shaft sleeve bronze with locking screw & lock nut
Bearing suitable for pump set make – SKF/NBC
Bearing Ring (DE & NDE) CI
Set of ‘O’ ring
CI gland cap with eye bolt complete
GM Gland sleeve bush
M&L for dismantling of centrifugal pump set from its foundation / base frame by disconnecting suction/delivery lines & coupling, opening, including required grinding, welding, machining, lathing, alignment, etc and re-assembling of centrifugal pump set 5.5 HP capacity including replacing worn out spare parts, re-commissioning & testing complete all as specified and as directed. Make - Kirloskar Note : Unserviceable parts required for replacement shall be paid separately as "Supply only" under serial item No. 18.01 to 18.08 here-in-after.
Supply only following spare parts for centrifugal pump of cap 5.5 HP, make - Kirloskar
Pump shaft stainless steel
Impeller brass/bronze complete with impeller key
Shaft sleeve bronze with locking screw & lock nut
Bearing suitable for pump set make – SKF/NBC
Bearing Ring (DE & NDE) CI
Set of ‘O’ ring
CI gland cap with eye bolt complete
GM Gland sleeve bush
S&F in replacement Fan Belt for AHU induction motor suitable for 3/5 HP motor, belt No A-43 13 X 1090 Li all as specified and as directed.
S&F in replacement Fan belt for AHU induction motor siutable for 3/5 HP motor, belt No. A-51 13 X 1300 Li complete all as specified and as directed.
S&F in replacement Fan belt for AHU induction motor siutable for 7.5 HP motor, belt No. A-30 13 X 760 Li complete all as specified and as directed.
S&F in replacement Fan Belt for AHU induction motor suitable for 7.5 HP motor, belt No. A-52 13 X 1320 Li all as specified and as directed.
S&F in replacement On Load Manual Changeover Switch, 630 Amps, 415 Volts, AC, 4 Pole, in sheet steel enclosure, complete all as specified and as directed.
S&F in replacement Voltmeter digital type 0-500 Volts complete all as directed.
S&F in replacement Ammeter digital type (0-200A) complete all as specified and as directed.
Supply & fixing in replacement PVC grill of size 600mm x 300mm x 150mm for cooling tower of capacity 125 TR / 140 TR AC Plant.
Supply & fixing in replacement eliminator for cooling tower of capacity 125 TR AC Plant.
Supply & fixing in replacement eliminator for cooling tower of capacity 4x10.2 TR AC Plant.
Supply & fixing in replacement eliminator for cooling tower of capacity 2x26 TR AC Plant.
Supply & fixing in replacement rotating sprinkler for cooling tower of capacity 125 TR AC Plant.
Supply & fixing in replacement rotating sprinkler for cooling tower of capacity 4x10.2 TR AC Plant.
Supply & fixing in replacement rotating sprinkler for cooling tower of capacity 2x26 TR AC Plant.
Servicing of double skin AHU comprising of cleaning inside cooling coil with appropriate cleaning chemical (ISI marked) as recommended by OEM and outside by vacuum cleaner and washing / cleaning of filters with chemical, oiling/greasing of moving parts of capacity as under :-
7250 CFM at AVA
25500 CFM at AVA
9100 CFM at AVA
17000 CFM at AVA
12000 CFM at 288 Fd Wksp
20000 CFM at 21 Mahar Regt
S&F in replacement chilled water sensor for 125 TR AC Plant of screw type compressor unit.
M&L for repair and programming of PLC card for 125 TR AC Plant.
M&L in replacement chiller water Temperature Meter.
S&F in replacement phase indicating lamp (LED type) RYB (Set of three) complete all as specified and as directed.
S&F in replacement Single Phasing Preventer, Auto reset, 50 Volts unbalance. Make : Type VSP-3 of Minilac or equivalent in makes mentioned in Appendix 'B' here-in-after.
S&F in replacement Heating element (ISI marked) of capacity 50 KW, 3 Phase, 415 Volt for strip type heater for heating system of Hot water generator of Make-Rapid Cool all as directed.
S&F in replacement Pressure meter 0-10 Kg/sqcm.
Supply & fixing in replacement air filter in GI frame of size 600mmx600mm & 50mm thick, washable type having filtration level upto 10-20 micron and efficiency 90% initial pressure drop 2.5mm WG of media synthetic non woven washable plus both side HDPE mesh type as per BS 2831 or 6540 (1985) complete all as specified and as directed ( Make : Athlete/Johnson)
S&F in replacement Low Pressure / High Pressure Switch for chiller unit of capacity 125 TR AC Plant (Make - Hitachi).
S&F in replacement External Oil Filter for chiller unit of capacity 125 TR AC Plant (Make - Hitachi).
S&F in replacement External Oil Filter for chiller unit of capacity 10.2 TR AC Plant (Make - Blue Star).
S&F in replacement External Oil Filter for chiller unit of capacity 26 TR AC Plant (Make - Blue Star).
S&F in replacement Internal Oil Filter for chiller unit of capacity 125 TR AC Plant (Make - Hitachi).
S&F in replacement Internal Oil Filter for chiller unit of capacity 10.2 TR AC Plant (Make - Blue Star).
S&F in replacement Internal Oil Filter for chiller unit of capacity 26 TR AC Plant (Make - Blue Star).
Supply & fixing in replacement Solenoid valve for 125 TR capacity chiller unit of make - Hitachi.
Supply & fixing in replacement Temperature Sensor for 125 TR capacity chiller unit of make - Hitachi.
Supply & fixing in replacement Syphon Valve for 125 TR capacity chiller unit of make specified by OEM (Hitachi).
Supply & fixing in replacement Drier Core for 125 TR capacity chiller unit of make - Hitachi.
Supply & fixing in replacement Display card for 125 TR capacity chiller unit of make - Hitachi.
Supply & fixing in replacement Safety release valve for 125 TR capacity AC Plant.
Supply & fixing in replacement Water Flow Switch for AC Plant of capacity 125/10.2/26 TR.
Supply & fixing in replacement Display card for 10.2 TR capacity AC Plant of make - Blue Star.
Supply, fixing, commissioning and testing programmable heavy duty Variable Frequency Drive (VFD) with digital display for 5.5 KW, 3 Phase, 440 Volt, 50 Hz and 1450 RPM induction motor complete all as specified and as directed, fixed in repairs. Make : Siemens/Schneider/Honeywell
S&F in replacement Direct-on-Line (DOL) starter suitable for Three Phase, 415 Volts, 3 HP centrifugal pump set and connection by using lugs/thimbles complete all as specified and as directed.
S&F in replacement sheet metal enclosure fully automatic star delta starter 3 Phase 415 Volt suitable for 7.5 HP centrifugal pump set and connection by using lugs/thimbles complete all as specified and as directed.
S&F in replacement sheet metal enclosure fully automatic star delta starter 3 Phase 415 Volt suitable for 15 HP centrifugal pump set and connection by using lugs/thimbles complete all as specified and as directed.
S&F in replacement sheet metal enclosure fully automatic star delta starter 3 Phase 415 Volt suitable for 20 HP centrifugal pump set and connection by using lugs/thimbles complete all as specified and as directed.
S&F in replacement sheet metal enclosure fully automatic star delta starter 3 Phase 415 Volt suitable for 25 HP centrifugal pump set and connection by using lugs/thimbles complete all as specified and as directed.
Supply and fixing in replacement MCB, SPN, 32 Amps, 240 Volts, AC supply, with overlaod and short circuit protection, 'C' curve and rupturing capacity 10 kA complete all as specified and as directed.
Supply and fixing in replacement MCB, SPN, 40 Amps, 240 Volts, AC supply, with overlaod and short circuit protection, 'C' curve and rupturing capacity 10 kA complete all as specified and as directed.
Supply and fixing in replacement MCB, Three Pole, 40 Amps, 415 Volts, AC supply, with overlaod and short circuit protection, 'C' curve and rupturing capacity 10 kA complete all as specified and as directed.
Supply and fixing in replacement MCB, 4 Pole, 63 Amps, 415 Volts, AC supply, with overlaod and short circuit protection, 'C' curve and rupturing capacity 10 kA complete all as specified and as directed.
S&F in replacement Power Contactor, 3 Pole, 25 Amp, AC3 rating, 415 Volt, 2NO + 2NC, complete all as specified and as directed. Make : Type ML-1.5 of L&T or equivalent in makes mentioned in Appendix 'B' here-in-after.
S&F in replacement Power Contactor, 3 Pole, 32 Amp, AC3 rating, 415 Volt, 2NO + 2NC, complete all as specified and as directed. Make : Type ML-2 of L&T or equivalent in makes mentioned in Appendix 'B' here-in-after.
S&F in replacement Power Contactor, 3 Pole, 40 Amp, AC3 rating, 415 Volt, 2NO + 2NC, complete all as specified and as directed. Make : Type ML-3 of L&T or equivalent in makes mentioned in Appendix 'B' here-in-after.
S&F in replacement Thermal overload relay, direct mounting on ML 2/3 Contactors, Relay Range 13-21 Amps, complete all as specified and as directed. Make : Type ML of L&T or equivalent in makes mentioned in Appendix 'B' here-in-after.
S&F in replacement Thermal overload relay, direct mounting on ML 1.5 Contactors, Relay Range 10-16 Amps, complete all as specified and as directed. Make : Type ML of L&T or equivalent in makes mentioned in Appendix 'B' here-in-after.
S&F MCCB, 3 Pole, 63 Amps rating, rupturing capacity 16 kA, 415 Volt grade, AC, 50 Hz, with adjustable Thermal - Magnetic release and making connections using suitable size copper lugs/thimbles and crimping tool, including disconnecting & taking down old unserviceable MCCB, complete all as specified & as directed.
S&F MCCB, 4 Pole, 100 Amps rating, rupturing capacity 25 kA, 415 Volt grade, AC, 50 Hz, with adjustable Thermal - Magnetic release and making connections using suitable size copper lugs/thimbles and crimping tool, including disconnecting & taking down old unserviceable MCCB, complete all as specified & as directed.
S&F MCCB, 4 Pole, 160 Amps rating, rupturing capacity 36 kA, 415 Volt grade, AC, 50 Hz, with adjustable Thermal - Magnetic release and making connections using suitable size copper lugs/thimbles and crimping tool, including disconnecting & taking down old unserviceable MCCB, complete all as specified & as directed.
S&F MCCB, 4 Pole, 200 Amps rating, rupturing capacity 36 kA, 415 Volt grade, AC, 50 Hz, with adjustable Thermal - Magnetic release and making connections using suitable size copper lugs/thimbles and crimping tool, including disconnecting & taking down old unserviceable MCCB, complete all as specified & as directed.
S&F MCCB, 4 Pole, 630 Amps rating, rupturing capacity 36 kA, 415 Volt grade, AC, 50 Hz, with adjustable Thermal - Magnetic release and making connections using suitable size copper lugs/thimbles and crimping tool, including disconnecting & taking down old unserviceable MCCB, complete all as specified & as directed.
rajesh builders
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .