Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1st₹5.2 LAccepted-AOC VILL NIDHANA DISTT FEROZEPUR | FEROZEPUR | 1st | Accepted-AOC Responsive bidder |
Tender Value
₹5.2 L
EMD Value
₹10,500
Closing Date
30 Sept 2020, 4:00 pmClosed
Executive Engineer DWSS Moga
Room No. 313 3rd Floor Jhelum Chenab Complex DAC Moga
Prov. and laying of pipelines, installation of House connections and minor repairs in village nahal khotte
2020_WB_53522_1
PRWSSIP/2020/Nahal Khotte
Open Tender
Civil Works - Water Works
Item Rate
60 days
Vill Nahal Khotte
Please refer Tender documents.
8 documents required · 8 mandatory
₹1
TIA
₹10,500
19 Nov 2020
18 Sept 2020
30 Sept 2020
18 Sept 2020
30 Sept 2020
18 Sept 2020
Amount
Providing & fixing G.I. Barbed wire 3 ply (strands of wire) conforming to IS : 278 fencing around the head works site in three rows complete in all respects including cost of winding wire & aluminum painting complete in all respects as per standard Drawing D-6 & 8
Provision for one No. Electronically actuated, Diaphragm Operated, Metering System, Chemical Dosing Chlorinator, suitable for delivering 0.5 to 6 Litres of Bleaching powder solution/ Sodium Hypo Solution per hour under maximum delivery pressure upto 7 ka.cm 2 and suction lift not less than 1.5 m, as per DWSS standard specifications complete in all respects
Providing & fixing angle iron pickets with angle 40mm x40mm x 6mm including cost of concrete block & painting complete in all respects as per standard Drawing D-8
Providing & fixing D.Hook complete with MS Bolts size 300mm x 18mm as per standard Drawing D-7
Providing & fixing C.I/D.I Flanged end, stem of SS (AIS 1410) and Bronze (gunmetal) working parts Sluice Valves ISI marked 14846-2000, including jointing, testing & cost of Nut, Bolt & inserting sheet, all carriage complete (with the approval of Engineer-in-charge) Class PN-1 as per ISI (CSR item 28.27 (A))
100 mm i/d Sluice Valve flanged
Construction of masonary Sluice Valve Chamber excluding Sluice valve cover as per standard design & drawings of public health department. (CSR item 28.66 (b))
Size (0.90 x 0.90 mtr)
Repair of leakages in Existing pvc pipe lines including excavation, Bailing out water, D joint & re-filling, etc. complete in all respects
90 mm o/d pvc pipe
110 mm o/d pvc pipe
Deduct credit of old Sluice valves
Minor repair in existing household connection (by Providing & fixing washer (electric welded) in the 15mm union on existing water connection etc.), Where water connections were installed by consumers, but not as per DWSS specifications.
Providing proposed water connection to house hold up to wall with providing, laying jointing, testing MDPE/GI pipe lines 15mm i/d=4.50 mtr, (2.50+2.00 mtrs)including cost of specials such as tees, bends, sockets, elbow etc. cutting, threading, and testing in trenches in the ground and ISI marked 10mm i/d GM ferrule as per IS: 2692 and 3" i/d uPVCclamp complete.
New Household Connections proposed On Existing / Replaced Pipeline
Providing, Laying, fixing & jointing of PVC Pipes as per ISI-4985 (ISI marked with the prior approval of Engineer-in-charge) along the Tranches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing including excavation & back filling complete as per specifications for more than 3 mtr street width. (CSR item 28.2,28.13 & 28.18))
PVC Pipe Line 90mm o/d 6 kgf/sq.cm
PVC Pipe Line 160mm o/d 6 kg.f/sqcm
Providing & fixing C.I/D.I Flanged end, stem of SS (AIS 1410) and Bronze (gunmetal) working parts Sluice Valves ISI marked 14846-2000, including jointing, testing & cost of Nut, Bolt & inserting sheet, all carriage complete (with the approval of Engineer-in-charge) Class PN-1 as per ISI (CSR item 28.27 (A))
80 mm i/d Sluice Valve flanged
Construction of masonary Sluice Valve Chamber excluding Sluice valve cover as per standard design & drawings of public health department. (CSR item 28.66)
Size (0.60 x 0.60 mtr)
Dismantling brick or flagged stone flooring without concrete base and relaying of dry brick on edge paving with a dismantled bricks including sand grouting.
Dismantling of metallic road with bituminous coruse 50 to 75 mm thick C.C. 1:8:16 and making good the same to its original condition complete in all respacts as per analysis A-26. NOTE:- Contractor shall quote rates only for dismantling mattle road and back filling with excavated earth, fully compacted. The restoration of the mattled road to its original condition will be done by the concerned department i.e. PWD (B&R)/PMB/Pnnchayti Raj.
Connection of new pipe line with existing pipe lines including excavation, Bailing out water, D joint & re-filling, etc. complete in all respects.
Repair of existing MS Sign Board including paint and writing complete in all respect.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .