| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.3 CrAccepted-AOC SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON WEST MUMBAI 400 104 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | ₹1.3 Cr | L1 | Accepted-AOC Being Lowest |
| 2 | L2₹1.4 Cr+₹8.4 L (6.36%)Rejected-Finance | ₹1.4 Cr+₹8.4 L (6.36%) | L2 | Rejected-Finance Being other than lowest |
| 3 | L3₹1.5 Cr+₹15.2 L (11.5%)Rejected-Finance PLOT NO 1134 1196 MORIVALI VILLAGE TAL AMBARNATH DIST THANE AMBERNATH 421505 | AMBERNATH | THANE | MAHARASHTRA | 421505 | ₹1.5 Cr+₹15.2 L (11.5%) | L3 | Rejected-Finance Being other than lowest |
| 4 | Rejected-Technical SWAGAT CO OP HSG SOCIETY LTD 22 303 CHAITANYA SHIVAJI RAJE COMPLEX MHADA COMPLEX OPP EKA NAGAR KANDIVALI W MUMBAI 400 067 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400067 | - | - | Rejected-Technical Not eligible as per note 1 on page 5 of tender |
| 5 | Rejected-Technical 1446 ELITE ENTERPRISES NORTH SOLAPUR NEAR SUSHIL MARATHI SCHOOL SOLAPUR MAHARASHTRA 413004 | SOLAPUR | MAHARASHTRA | 413004 | - | - | Rejected-Technical Three class below |
Tender Value
Refer Docs
EMD Value
₹2.1 L
Closing Date
1 Jul 2021, 6:00 pmClosed
CWE (NW) Mumbai
Commander Works Engineer NW Dr Homi Bhabha Road Navy Nagar Colaba Mumbai 05
M and O AND REP REPLACEMENT OF CENTRAL AC PLANTS AND COLD STORAGE PLANTS INSTALLED AT VARIOUS BLDGS UNDER GE (NW) KUNJALI AND REPAIR MAINTENACE OF SPLIT WINDOW AC ETC AT LHS OF NAVAL DOCKYARD UNDER GE (NW) KUNJALI COLABA MUMBAI
2021_MES_447553_1
8406/CWE(NW)/MUMBAI
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
GE (NW) KUNJALI
Class B
7 documents required · 7 mandatory
₹1,000
Yes
GE (NW) KUNJALI
₹2.1 L
Yes
12 Aug 2021
1 Jun 2021
3 Jul 2021
1 Jun 2021
1 Jul 2021
25 Jun 2021
1 Jun 2021 - 21 Jun 2021
Amount
PART-I (Manning and operation) Manning & operation of Central chilled water type AC plant 02 Nos x 15 TR run in three shifts per day (each shift 08 hrs) (one running & one standby) operated by one Refg Mech in each shift including maintaining record periodical minor maint/ repairs (ie daily check, monthly, quarterly and half yearly) with all consumable parts except for major repair and spare parts of central AC plant Make :- Voltas Model No ACC WC03000 MNT at COMCEN REAR AC PLANT complete with cooling tower AHU & other accessories including maintain cleaness of AC plant for 24 hours run daily in three shifts (06.00 hrs to 14.00 hrs, 14.00 hrs to 22.00 hrs and 22.00 hrs to 06.00 hrs) including Sundays and Holidays consisting of followings:- ( 3 shift x 11 month = Total 33 shifts)
(a) Compressor Make :- Voltas Model No ACC WC03000 MNT -02 Nos. (b) Compressor motor 15 HP-02 Nos. (c) Condenser/ chiller water pump set mono block 3HP-04Nos. (d) Air Handling Unit with blower motor -01No. (e) FRP Cooling tower with CT Fan- 01No. (f) Electrical control panel cubical type floor mounted with main switch, MCCB's,Voltmeter, Ammeter, Motor Starters etc. complete-01 Set. (g) Control devices such as expansion valve thermostat solenoid valves HP/ LP/ CP cut outs with panel board installed gauges-01Set (h) Digital type thermometer-01Set (j) Air supply duct with grill diffusers dampers and heater etc. complete-01Set (k) Condensers and Condenser piping, Chilled water piping lines 100/80/50mm with valves, water pressure gauge and water temperature gauge complete-01Set
Manning & operation of following 02 Nos (two in numbers) Central AC Plants TPW and NAD run in one shift per day (shift 08 hrs) each installation operated by one Refg Mech including maintaining record periodical minor maint/ repairs (ie daily check, monthly, quarterly and half yearly) with all consumable parts except for major repair and spare parts of central AC plants at TPW, NAD A-63 Building Naval Dockyard including daily cleaning of AC plants complete with cooling tower AHU & other accessories for 08 hours run daily in one shift of both plants including Sunday and Holidays from 0900 hrs to 1700 hrs. Plants detail as following:-( 1 shift x 11 month = Total 11 shifts)
NAD AC PLANT :- 02 Nos x 40 TR, Make :- Voltas Model No ACC WC04000 MNT (a) Compressor Make Voltas Model No ACC WC04000 MNT -02 Nos. (b) Compressor motor 60HP-02Nos. (c) Condenser/ chiller water pump set mono block -04Nos. (d) Air handling unit with blower motor -01No. (e) FRP Cooling tower with CT Fan- 01No. (f) Electrical control panel cubical type floor mounted with main switch MCB's voltmeter, Ammeter, Starter condenser etc. complete-01 Set. (g) Control devices such as expansion valve thermostat solenoid valves HP/ LP/ CP cut outs with panel, panel board installed gauges-01Set (h) Digital type thermometer-01Set (j) Air supply duct with grill diffusers dampers and re-heater, pre-heaters etc. complete-01Set (k) Condensers and Condenser piping, Chilled water piping lines 100/80/50mm with valves, water pressure gauge and water temperature gauge complete-01Set
TPW AC PLANT:- 2 Nos. x 50 Ton, Make: Voltas, model No. AC WC05000MNT (a) Compressor model No. ACCWC05000MNT-02Nos. (b)Compressor motor 60HP-02Nos. (c) Condenser / chiller water pump set mono block 7.5HP-04Nos. (d) Air handling unit with blower motor 15HP-01No. (e) FRP Cooling tower 60TR with CT Fan-01No. (f) Electrical control panel cubical type floor mounted with main switch MCB's voltmeter, Ammeter, Starter condenser etc. complete-01Set. (g) Control devices such as expansion valve thermostat solenoid valves HP/LP/CP cut outs with panel board installed gauges -01Set (h) Digit type thermometer-01 Set. (j) Air supply duet with grill diffusers dampers and heater etc. complete-01Set. (k) Condensers and Condenser piping, Chilled water piping lines 100/80/50mm with valves, water pressure gauge and water temperature gauge complete-01Set
Manning and Operation of package type AC plant of capacity 06 Nos x 7.5 TR, Make :- Blue star, Model PAW-710 at VAJARABAHU ND running daily round the clock (24 hrs) in 3 shifts ie (06.00 hrs to 14.00 hrs, 14.00 hrs to 22.00 hrs and 22.00 hrs to 06.00 hrs) for smooth functioning of entire system and to maintain specific temperature including daily cleaning area of AC plant complete including Sunday & Holidays. AC Plant consists of the following accessories of AC Plant :- ( 3 shifts x 11 month = Total 33 shifts)
(a) Package type Air Conditioning Plant sealed compressor and water cooled condenser -06Nos. (b) Mono block pump set 5HP-02Nos. (c) FRP type cooling tower with CT fan motor-01Nos. (d) Electric control panel cubical type with Main Switches, Starters, Voltmeter, Ammeter & contractors-01Set. (e) Control devices such as thermostatic expansion valves, thermostarts, solenoid valves HP/ LP cut out switches oil failure pressure cut out switches etc. & installed gauges of each unit (f) Sealed AHU with cooling coil and Blower and Blower motor of each unit -01Set. (g) Ducting for supply air with grills, diffusers, dampers and heaters bank etc.-01 Set
Manning & operation of Central AC Plants in one shift per day (shift 08 hrs) operated by one Refg Mech including maintaining record periodical minor maint/ repairs (ie daily check, monthly, quarterly and half yearly) with all consumable parts except major repair and spare parts of central AC plant CCDT (B) Naval Dockyard complete of 02 Nos x 7.5 TR capacity (Make : Kirloskar Model AK- 3) with cooling tower AHU and other accessories (one running and one standby) for single shift of 08 hrs daily from 0900hrs to 1700hrs including Sundays & Holidays including maintain cleaness of AC plant all as specified and directed by Engineer- in-charge. ( 1 shift x 11 month = Total 11 shifts)
(a) Compressor make Kirloskar model FK-4 - 02Nos. (b) Compressor motor 10HP-02Nos. (c) Condensor water pump set mono block 3.0HP-02Nos. (d) Air Handling Unit with blower motor-01No. (e) FRP Cooling tower 10TR capacity with CT fan-01No. (f) Electrical control panel cubical type floor mounted with main switch MCCB's, Voltmeter, Ammeter, Starters etc. complete-01Set. (g) Control devices such as thermostatic expansion valve, solenoid valves HP/ LP/ CP cut outs with panel board installed gauges-01 Set. (h) Digital type thermometer-01 Set. (j) Air supply duct with grill diffusers dampers and heaters etc.complete-01Set. (k) Condensers and Condenser piping, Chilled water piping lines 80/50mm with valves, water pressure gauge and water temperature gauge complete-01Set
Manning & operation of Central AC Plant in one shift per day (each shift 08 hrs) operated by one Refg Mech in each shift including maintaining record periodical minor maint/ repairs (ie daily check, monthly, quarterly and half yearly) with all consumable parts except major repair and spare parts of central AC plants condensing unit complete of 3 Nos. x 40 Ton (two running & one standby ) (Make :- Voltas, Model No. ACWCURO0400MNT at MWC building No.173 (ND) including maintain cleaness of AC plant complete with cooling tower AHU & other accessories run for one shift daily from (09.00 hrs to 17.00 hrs) including Sundays & Holidays ( 1shift x 11 month = Total 11 shifts)
(a) Compressor model ACWCURO0400MNT- 03Nos. (b) Compressor motor 50HP-02Nos. (c) Condensor water pump set mono block 7.5HP-02Nos. (d) Air Handling Unit with blower motor-01No. (e) FRP Cooling tower 80TR capacity with CT fan-01No. (f) Electrical control panel cubical type floor mounted with main switch MCCB's, Voltmeter, Ammeter, Starters etc. complete-01Set. (g) Control devices such as thermostatic expansion valve, solenoid valves HP/ LP/ CP cut outs with panel board installed gauges-01 Set. (h) Digital type thermometer-01 Set. (j) Air supply duct with grill diffusers dampers and heaters etc.complete-01Set. (k) Condensers and Condenser piping, Chilled water piping lines 100/80/50mm with valves, water pressure gauge and water temperature gauge complete-01Set
Manning and Operation of Walk in Cooler ( Mutton Point CG Complex ) running round the clock in ( three shifts) each shift of 08 hour ( 06.00 hrs to 14.00 hrs, 14.00 hrs to 22.00 hrs and 22.00 hrs to 06.00 hrs) daily including Sundays and Holidays including maintaining cleaness of AC plant of the following plants :- ( 3 shift x 11 month = Total 33 shift)
(a) 03 Nos cabinet/ rooms of Walk in cooler consisting total 09 Nos refrigeraion units having capacity of each unit 2TR driven single phase, Emerson hermetically sealed compressor units model CR-1010 BCU10 ( 02 running & one standby in each walk in cooler room) for maintain the temperature range 08° C to 12°C RH 60% for eggs room. Make: Blue Star (b) 02 Nos Walk in cooler having refrigerant unit 06 Nos x 10TR each three phase hermetically sealed compressor Model LC-2120 (02 Nos running and one stand by in each walk- in- cooler) for maintaining the temperature range (-) 18°C to (-) 20°C RH 50% for fish/ mutton/ chicken room Make :- Blue star
Manning and Operation of central AC chilled water plant 02Nos x 50 TR (one running & one standby) Total 50 TR make: Voltas, model No. AC WC06000MNT at MOC INS ANGRE complete including maintaining cleaness of AC plant with cooling tower AHU & other accessories for 24 hours run daily in three shift, each shift 08 hour ( 06.00 hrs to 14.00 hrs, 14.00 hrs to 22.00 hrs and 22.00 hrs to 06.00 hrs) including Sundays and Holidays consisting of followings:- ( 3 shift x 11 month = Total 33 shift) (a) Compressor model No. ACCWC06000MNT-02Nos. (b) Compressor motor 75 HP-02Nos. (c) Condenser / chiller water pump set mono block 7.5HP-04Nos. (d) Air Handling unit with blower motor -01No. (e) FRP Cooling tower 60TR with CT Fan-01No. (f) Electrical control panel cubical type floor mounted with main switch, MCCB's, Voltmeter, Ammeter, Starters, condenser etc. comple-01Set. (g) Control devices such as thermostatic expansion valve, thermostats, solenoid valves HP/LP/CP cut outs with panel board installed gauges -01Set. (h) Digital type thermometer-01 Set. (j) Air supply duct with grills, diffusers, dampers and heaters etc. complete-01Set. (k) Condensers and Condenser piping, Chilled water piping lines 100/80/50mm with valves, water pressure gauge and water temperature gauge complete-01Set Note :- (i) Passes will be processed alongwith (after verification on signed certificate, verified ITI certificate only. Pass shall not be granted without submission of ITI qualification proof & experience certificate. In case of OEM, the qualification mentioned in note is not applicable which shall be verified by Engineer-in-Charge before issue of pass
Note :- For item No 1 to 7 (a) Surprise check will be carried out by department representative and if any employes is not available at his working place, he will be treated as absent. (b) Contractor has to submit the list of employees including reserve alongwith police verification, Aadhar card, Aadhar card linked Bank Account No and relevant documents as mentioned in PS to the Engineer-in-Charge alongwith performance security before issue work order. (c) The payment shall be made to employees on or before 10th of every calender month. Payment to employees shall be done by crossed cheque / RTGS / NEFT / IMPS through Aadhar card linked Bank Account only and it shall not be less than minumum fair wages as per Act in vogue (d) Contractor has to submit proof of payment of EPF subscription made by his alongwith RAR failing which RAR will not be progressed for payment (e) Contractor has to employ the number of labours per day as intimated by the Engineer-in-Charge for which he has to make alternative arrangement. (f) The rates quoted by the contractor shall be deemed to be included provision of all latest labour laws / regulations including all relevant taxes as applicable. (g) Contractor shall quote the rates considering their monthly leaves, releiver etc as per labour laws and nothing extra shall be paid on account of the above. In case of absence of staff/tradesman from duty, payment of that day will not be paid. In addition to that a penalty of Rs 1500/- per day per person will be recovered from contractors dues. Also in case of long absence (more than one week) of staff/tradesman, the penalty shall be recovered including Sundays & Holidays if any. The contractor shall have no claim on this account.
(h) Contractor has to supply three sets of Tools and Plants (as applicable) to the labours employed by him and should be placed with the safe custody of department. Rates quoted shall be deemed to be included the above provision. (j) In case any variation in manpower as indicated in Column No 4 of BOQ due to any reasons / or any manpower held in Department or any policy change contractor should have no claim on that account. (xiii) The bidders are advised not to quote rate less than minimum fair wages as circulated by competent authority. If the quoted amount is less than the estimated cost Item No 1 to 7 i.e Rs 60,57,216.00 , the lowest bidder will have to deposit FDR/BGB as elaborated herein after in favour of Accepting Officer within 07 days of opening of financial bid (Cover No 2) . (xiv). The deposited amount shall be the difference between estimated cost i.e Rs 60,57,216.00 and amount quoted by lowest bidder for respective item. FDR/BGB shall be released only after satisfactory completion of work. If the contractor fails to pay minimum wages to employees, the department shall have right to withhold the said amount which will be verified by GE. The decision of Accepting Officer regarding amount to be withhold shall be final and binding. The withhold amount will be utilised by GE for payment to employees if contractor fails to pay minimum wages and balance amount if any shall only be released. If the lowest bidder fails to deposit the amount as stated above within 07 days, the contractor shall be banned for 06 months & his bid shall be rejected. The contractor shall sumbit 03 Nos of BGBs/FDRs of equal amount as mentioned above. The BGBs/FDRs validity shall be 04 months, 08 month & 12 months respectively for the purpose of encashment/ release as the case may be. (xv) The rates quoted shall be inclusive of suitable reliver wherever sundays & holidays are mentioned for working (m) Quotes rates should include Stationary,Uniform,Shoes,log book.etc
Part- II (Repair & Replacement ) Pumping down the compressor and transfer existing refrigerent gas complete for overhauling of compressor reciprocating open type model FK - 4 Kirloskar Make 2 x 7.5 TR Capacity, dismantling complete assembly & replacing of minor unserviceable parts including machining of crank shaft boring polishing etc replacing of gaskets packing reassembly and recharging of pumped down refrigerant & topping up if required to maintain the required standing pressure charging of compressor oil complete testing for smooth functioning etc.at CCDT ND (Note : Major spare parts, compressor oil and refrigerant gas for topping up will be paid separately )
All as per item No 8.00 above but for 2 x 60TR AC Plant at MOC INS ANGRE of compressor model no:5H60 Voltas
All as per item No 8.00 but for 2 x 50TR AC Plant at NAD A-63 Naval Dockyard of compressor model no:5H60 Voltas
All as per item No 8.00 but for 3 x 30TR AC Plant at COMCEN INS ANGRE of compressor model no:5F20 Voltas
All as per item No 8.00 but for 3x 40TR AC Plant at MWC Bldg No 173 (ND) of compressor model no:5H60 Voltas
All as per item No 8.00 but for 2 x 15 TR AC Plant at COMCEN REAR INS ANGRE of compressor model No 5H40 Voltas
Material and labour for cleaning of cooling coil section of AHU for descaling and providing 02 Nos.15mm Tee outlet for local circulation of MAIC solution in the cooling coil (separate container and pump set of appropriate capacity to be used for circulation) pH value of solution to be kept at 4 & checked at an interval of 01 hr. duration process the scalgum / WS / Cleansol or equivalent solution to be used for descaling if ph value remains less than '7' flush with fresh water added to sodium carbonate till pH value attains '7' refix the coil section in position minor repairs to be carried out in AHU Coil bins to be cleaned by scalgum solution by spraying the solution with washing pump up to required level, AHU and complete all as specified and directed for the followings :-
AHU of 2 x 50TR Capacity AC Plant at NAD A-63 Naval Dockyard
AHU of 2 x 60TR Capacity AC Plant at MOC INS ANGRE
AHU of 3 x 30TR Capacity AC Plant at COMCEN INS ANGRE
AHU of 2 x 15 TR Capacity AC Plant at COMCEN REAR INS ANGRE
Dismantling AHU of 2 x 60TR TR capacity AC plant carefully by removing side and top panel removing unserviceable blower shaft bearings,removing motor & blower assembly, replacement of new AHU blower shaft bearings reassembling blower assembly and refixing electric motor & top side panel in original position with new nut bolts washers & shafts keys & checking the shafts balancing & testing for smooth running all as specified and directed at MOC INS ANGRE.
All as per item No 15 but for 2 x 50TR AC Plant at NAD A-63 Naval Dockyard.
All as per item No 15 but for 3 x 30TR AC Plant at COMCEN INS ANGRE
All as per item No 15 but for 2 x 7.5 TR AC Plant at CCDT(ND)
All as per item No 15 but for 3x 40TR AC Plant at MWC Bldg No 173(ND)
All as per item No 15 but for 6x 7.5 TR AC Plant at A - 14 Bldg (ND)
All as per item No 15 but for 2 x 15 TR AC Plant at COMCEN REAR INS ANGRE .
Material and labour for dismantling cooling tower by removing CT Fans, sprinklers, PVC filler and clean cooling tower body by removing scale , dust, dirt and refix PVC filler by cleaning with diluted HCL solution reassembling, connecting , cleaning external surface and applying two coats of approved synthetic enamel paint including writing SM number/ marking and testing etc. complete all as specified and directed for the following capacity cooling towers for the following :-
Cooling tower of 3 x 30 TR Capacity at COMCEN INS ANGRE
Cooling tower of 2 x 50 TR Capacity at NAD A-63 Naval Dockyard
Cooling tower of 6 x 7.5 TR Capacity at A - 14 (Naval Dockyard)
Cooling tower of 3 x 40 TR Capacity at MWC Bldg. No. 173.(Naval Dockyard)
Cooling tower of 2 x 15 TR Capacity at COMCEN REAR INS ANGRE .
Supply and fix in replacement of unserviceable / worn-out 'V' Belt of AHU's of Make Fenner/Dunlop/ Nerlon
Supply and fix in replacement of unserviceable / worn-out rubber coupling suitable for compressor shaft and motor shaft complete all as specified Make Fenner /Dunlop/ Nerlon
Taking out old unserviceable 2 x 15 TR Delta make cooling tower fills sheets from the site and supply and fix new fibre fills sheet of same size for cooling tower as per the existing at site and all as specified and directed by Engineer-in-Charge at COMCEN REAR INS ANGRE.
Taking out old unserviceable 3x30 TR Delta make cooling tower fills sheets from the site and supply and fix new fibre fills sheet of same size for cooling tower as per the existing at site and all as specified and directed by Engineer-in-Charge at COMCEN INS ANGRE.
Taking out old unserviceable cooling tower fills sheets of 2X50 TR from the site and supply and fix new fibre fills sheet of same size for cooling tower as per the existing at site and all as specified and directed at NAD A-63 Naval Dockyard
Taking out old unserviceable cooling tower fills sheets of 6x7.5 TR from the site and supply and fix new fibre fills sheet of same size for cooling tower as per the existing at site and all as specified and directed at Vajrabahu Naval Dockyard
Taking out old unserviceable cooling tower nozzles and supply and fix new cooling tower nozzles suitable for 3x30 TR Mihir make cooling tower as per existing at at COMCEN INS ANGRE.
Taking out old unserviceable cooling tower nozzles and supply and fix new cooling tower nozzles suitable for 2x 60 TR Mihir make cooling tower as per existing at NAD A-63 Naval Dockyard
Material and labour for disconnecting condenser for descaling & plugging them & providing of 15 mm tee out let for local circulation of mild acid solution in the condenser (separate container and small pump set to circulate diluted acid solution to be used) pH value of solution to be circulated & to be kept 4 and checking frequently i.e. every one hour during the operation Scalgun WS solution to be used for descaling purpose after 2 to 3 hours of cleaning if ph value remains less than 7 flush with fresh water mixed with sodium carbonate tubes and cleaning with nylon brush after closing the end covers, circulating diluted acid solution as specified above & pH value to be maintained as above & flushing the same with fresh water including recharging of stored refrigerant up to required pressure complete all as specified & directed by Engineer-in-Charge of for the following :-
Condenser of 2 x 50TR Capacity AC Plant at NAD A-63 Naval Dockyard
Condenser of 2 x 60TR Capacity AC Plant at MOC INS ANGRE
Condenser of 3 x 30TR Capacity AC Plant at COMCEN INS ANGRE
Condenser of 2 x 7.5 TR Capacity AC Plant at CCDT (ND)
Condenser of 3 x 40TR Capacity AC Plant at MWC Bldg. No. 173(ND)
Condenser of 2 x 15TR Capacity AC Plant at COMCEN REAR INS ANGRE
Material and labour for disconnecting for Chiller descaling & Plugging them & providing of 15 mm tee outlet for local circulation of mild acid solution in the Chiller (separate container and small pump set to circulate diluted acid solution to be used) pH value of solution to be circulated & to be kept 4 and checking frequently i.e. every one hour during the operation Scalgun WS solution to be used for descaling purpose after 2 to 3 hours of cleaning if ph value remains less than 7, flush with fresh water mixed with sodium carbonate tubes and cleaning with nylon brush after closing the end covers, circulating diluted acid solution as specified above & pH value to be maintained as above & flushing the same with fresh water including recharging of stored refrigerant up to required pressure complete all as specified & directed by Engineer-in-Charge of for the following :-
Chiller of 2 x 50TR Capacity AC Plant at NAD A-63 Naval Dockyard
Chiller of 2 x 60TR Capacity AC Plant at MOC INS ANGRE
Chiller of 3 x 30TR Capacity AC Plant at COMCEN INS ANGRE
Chiller of 2 x 15 TR Capacity AC Plant at COMCEN REAR INS ANGRE
Pumping down the existing refrigerant from the condensor and carrying out the leak test of plant with the pressure of Nitrogen gas and monoitoring for 24hrs asses leakages by brazing & replacement of necessary gasket wherever required including copper tubes of suitable size vacumizing of the plant by vaccum pump finally reharging of existing refrigerant gas to the plant and topping up of refrigerant if required to maintain the standard pressure etc complete including testing of the plant for smooth functioning complete all as specified & directed. (Note: Refrigerant required for topping up will be measured and paid separately under relevant items)
Rewinding of unserviceable electric motor 3 phase 50 Hz 415volt of following capacity pump set complete comprises as under :- (a) Disconnecting & removing the electric motor from installed position including, loading, unloading and transporting to approved workshop. (b) Taking out the existing burnt winding from the motor including rewinding complete with super enameled copper winding wire of existing gauge including all insulating material such as insulation paper, sleeves, tape, varnish etc. complete for class 'F' insulation. (c) Transporting the motor back to the location, reinstalling in original position including alignment, electrical & water connection, commissioning and testing for 8hours continuously to check the RPM etc. to the satisfactory performance etc. complete. NOTE: Any damage caused during handling will be made good by contractor without any extra cost to department
7.5 HP Chiller / Condenser Water Pump Motor .
15 HP Chiller/Condenser Water Pump Motor.
5.0 HP Chiller/Condenser Water Pump Motor.
3.0 HP Chiller/Condenser Water Pump Motor.
10 HP Condenser/Chiller Water Pump Motor.
15 HP Compressor Motor .
60 HP Compressor Motor .
40 HP Motor.
50 HP Motor.
25 HP Motor.
Over hauling of Monoblock pump set after removing from the base plate, disconnecting from pipe line, dismantling the pump set, replacing unserviceable gland packing, gun metal bush bearing water seal applying grease etc. complete and reassembling the pump set connecting with pipe line reconnection of electric supply, including buts bolts, gaskets etc. complete testing of pumps for smooth functioning with following capacity of pumps and motors:-
7.5 HP Chiller / Condenser Water Pump
15 HP Chiller/Condenser Water Pump
5.0 HP Chiller/Condenser Water Pump
3.0 HP Chiller/Condenser Water Pump
10 HP Condenser/Chiller Water Pump
Over hauling sevicing of electric motor after removing from the base foundation including disconnecting of electric connection and replacment of unserviceable ball bearing complete and reassembling, realignment and reconnection of electric supply complete and testing on load for smooth functioning of following capacity motors:-
15 HP Motor .
60 HP Motor .
40 HP Motor.
50 HP Motor.
25 HP Motor.
10 HP Motor
Supply and charge refrigerant R-22 gas in AC plant system as per requirement.
Replacement of compressor oil with new compressor oil as specified and directed by EIC
Material and labour for repairs to Microprocessor of 50/60 TR Capacity chiller unit including replacing diods , transistors and wiring etc for AC Plant at NAD A-63 Naval Dockyardall as specified and directed
Material and labour for Expansion valve of 50TR/60TR chiller unit including taking down old unserviceable valve complete all as specified and directed by Engineer-in-Charge .Make: Sporlon or equivalent
Material and labour for Expansion valve of 30/40TR chiller unit including taking down old unserviceable valve complete all as specified and directed by Engineer-in-Charge.Make: Sporlon or equivalent
Material and labour Expansion valve of AC plant capacity 7.5/15 TR including taking down old unserviceable valve complete all as specified and directed by Engineer-in-Charge. Make: Sporlon or equivalent
Taking down old unserviceable shaft seal assembly complete and Supply and fix new shaft seal assembly suitable for 60/50 TR Capacity chiller unit all as specified and directed by Engineer-in-Charge .
Taking down old unserviceable shaft seal assembly complete and Supply and fix new shaft seal assembly suitable for 30/40 TR Capacity chiller unit all as specified and directed by Engineer-in-Charge .
Taking down old unserviceable shaft seal assembly complete and Supply and fix new shaft seal assembly suitable for 15/7.5 TR Capacity chiller unit all as specified and directed by Engineer-in-Charge .
Taking down old unserviceable CI butter fly valve and supply and fix new CI Butter fly valve slim seal design with nitrile rubber lined seat with clutch lever (p10)as per IS 13095 of the following size. Make: AUDCO/SANT as approved.
Taking down old unserviceable Non Return valve and supply and fix new CI Non Return valve of the following size. Make: -Kirloskar /Kartar/Zoloto/Leader as approved
Taking down old unserviceable Strainer of any make and size and supply and fix new Strainer of the following size.
Supply and fix Condensor safety valve suitable for chiller unit all as specified and directed by Engineer-in-Charge.
Material and labour for HP cut out including taking down old one Make : Indofoss .
Material and Labour for LP cut out including taking down old one Make : Indofoss.
Material and labour for oil pressure cut out controls for compressor including taking down old one Make : MP 55 Indofoss .
Removing old unserviceable power contactor and supply & fix new power contactor MNX -32 all as specified & directed by Engineer-in-Charge Make : L & T or equivalent
Removing old unserviceable power contactor and supply & fix new power contactor MNX -40 all as specified & directed by Engineer-in-Charge Make : L & T or equivalent
Removing old unserviceable power contactor and supply & fix new power contactor MNX-18 all as specified & directed by Engineer-in-Charge Make : L & T or equivalent
Removing old unserviceable contactor and supply & fix new power contactor ML-2 all as specified & directed by Engineer-in-Charge
Removing old unserviceable contactor and supply & fix new power contactor ML-3 all as specified & directed by Engineer-in-Charge
Removing old unserviceable contactor and supply & fix new power contactor ML-4 all as specified & directed by Engineer-in-Charge
Removing old unserviceable contactor and supply & fix new Auxiliary contactor all as specified & directed by Engineer-in-Charge
Removing old unserviceable timer from compressor panel and supply & fix Timer 800 SD of Simens make for Compressor motor all as specified & directed.
Removing old unserviceable timer and supply & fix GT Timer of L&T make for Condenser motor all as specified & directed.
Replacement of bimetal over load relay of range 14-23 Amps direcectly operated suitable for 10 HP motor Make :- L&T /SIEMENS
Replacement of bimetal over load relay of range 9-15 Amps direcectly operated suitable for 5 HP motor Make :- L&T /SIEMENS
Taking down old unserviceable AHU Blower and Supply and fix new AHU Blower all as specified & directed
Taking down old unserviceable AHU Blower Drum and Supply and fix new AHU Blower Drum all as specified & directed
Taking down old unserviceable AHU Blower shaft and Supply and fix new AHU Blower shaft all as specified & directed
Taking down old existing MS pipes supply, lay and welding MS pipes heavy grade with all fittings laid in floors or fixed to walls and ceilings etc of following sizes:
Taking down old existing GI pipes supply, lay and welding GI pipes heavy grade with all fittings laid in floors or fixed to walls and ceilings etc of following sizes:
Removing the unserviceable liquid line valve of size 15 mm from the liquid line after pumping down the compressor & supply and fixing new liquid line valve 15 mm including connected works as required for smooth functioning of AC plants complete all as specified & directed by Engineer-in-Charge
Removing the unserviceable liquid line valve of size 25 mm from the liquid line after pumping down the compressor & supply and fixing new liquid line valve 25 mm including connected works as required for smooth functioning of AC plants complete all as specified & directed by Engineer-in-Charge
Removing unserviceable thermostat of central AC plant & supplying and fixing new thermostat of range 5 degrees centigrade to 25 degrees centigrade complete with all accessories all as specified & as directed by Engineer-in-Charge
Removing the unserviceable solenoid valve assembly 5/8" flare size and Supply and fix new solenoid valve assembly 5/8" suitable for AC plant of various capacities complete with all as specified and as directed
Removing the unserviceable solenoid coil and Supply and fix new solenoid coil suitable for AC plant of various capacities complete with all as specified and as directed
Removing the unserviceable chiller water sensor and supplying and fixing new chiller water Sensor of suitable capacity complet all as specified & directed by Engineer-in-Charge
Removing the unserviceable pressure Sensor HP / LP / OP from and supplying and fixing new pressure Sensor of suitable capacity complete all as specified & directed by Engineer-in-Charge
Removing the unserviceable pressure gauges HP / LP / OP from existing position and supplying and fixing new pressure gauge of capacity 0 to 30 Kg / square centimeter complete with necessary accessories all as specified & directed by Engineer-in-Charge
Removing the unserviceable water pressure gauges from water line & supplying and fixing new water meter up to pressure 0 to 7 Kg / square centimeter complete with all accessories all as specified and directed by Engineer-in-Charge
Material and labour for scraping cleaning and preparation of external surface and painting complete installation at 2 X 7.5 TR (15 TR capacity) including compressor motor piping cooling tower condenser AHU and panel Board etc with two coats of synthetic enamel paint over a coat of red oxide zinc chromate primer as per ENCs colour code as given including writing to SM & MES numbers complete all as per specified & as directed by Engineer-in-Charge. Location : CCDT ND
All as per item No 78 above but of 3 x 40 TR (120 TR Capacity) Location : MWC Bldg. No.173
All as per item No 78 above but for 2 x 60TR (120 TR Capacity )AC Plant at MOC INS ANGRE.
All as per item No 78 above but for 2 x 50TR (100 TR Capaciry)AC Plant at NAD A-63 Naval Dockyard.
All as per item No 78 above but for 3 x 30TR (90 TR Capacity) AC Plant at COMCEN INS ANGRE .
Taking down old unserviceable AHU pre filter and Supply and fix new pre filters efficiency 90% down to particular size of 10 micron double knitted twisted polymer fabric (washable) rated with press drop of 6 mm WC, including aluminium anodized frame work of 16 SWG to be mounted in AHU filter assembly size as per existing. Make: ASPAWYMAN/DYNA/MHP as approved
Taking down old unserviceable aluminium rectangular duct grill of any size and make and supply and fix new fresh air /return air of aluminium rectangular grills complete with wooden frame work made out of II nd class hard wood, volume control damper including gasket and connected accessories complete all as directed by Engineer-in-Charge.
Supply, errect and fabricated rectangular square duct made out of 24/22 gauge GI sheet in L shaped hollow profile including all accessories such as corner, carriage bolt hangers, gasket and seal the longitudinal joints with and including approved sealant complete all as specified and directed by Engineer-in-Charge.
Taking down old unserviceable insulation from any surface and supply and fix nitrile rubber insulation (Armaflex) of one layer of 19mm thickness sticking on surface by using approved adhesive and sealing the joints by weather proof tape all as directed by Engineer-in-Charge.
M & L for Detecting the gas leakage, rectifying the defects by vacumizing and charging fresh referigerant gas and commissioning and testing the window type air conditioner unit 1.5Ton capacity complete all as specified and directed.
All as per item No. 87 above but of 2.0 Ton capacity
All as per item No. 87 above but of Split type AC 1.5 Ton Capacity.
All as per item No. 87 above but of Split type AC 2.0 Ton Capacity.
All as per item No. 87 above but of Refrigerator 100/165/180/230 Ltrs. Capacity.
All as per item No. 87 above but of Refrigerator 260/280/310/350 Ltrs. Capacity.
All as per item No. 87 above but of Water cooler 40/60/80 Ltrs. Capacity.
All as per item No. 87 above but of Water cooler 120/150/180 Ltrs. Capacity.
M & L for Taking out window type Air conditioner 1.0/1.5/2.0Ton capacity of any make from its original location, removing the dust from body with blower, cleaning the condenser and cooling coil by using water and caustic soda, painting the base tray with one coat of black enamel paint checking all the connections including functioning of metal clad socket/ DP switch function of relay capacitors overload protector thermostat fan motor blade fan blower drum etc. oiling/ greasing of fan motor checking serviceability and refixing it in its original place including testing commissioning for 1.0/1.5/2.0 Ton of AC of any make all as specified & directed by Engineer-in-charge.
All as per item No. 95 above but of split type AC 1.5/2.0 /2.5 Ton capacity complete out door and indoor.(Note for item nos.95 & 96:Refrigerant gas will be measured & paid separately as supply only under respective items.)
Cutting out existing wall / window grills / existing window frame for making suitable space to accommodate window type AC making frame with 2nd class hard wood piece of min of 50 x 50 mm size & up to 60 cm height for fixing of outer cover of AC & supporting structure made out 40 mm x 40 mm x 5 mm thick MS angle iron duly grouted in wall & closing the open space around ACs with the help of 6 mm thick ply wood exterior grade to close air leakage tightening with woolen felt (green felt) and painting to wooden structure matching to interiors as directed & steel structure with one coat of primer and two coats of synthetic black enameled paint and fixing only window type AC all as directed by EIC including complete connecting and testing all as specified and directed by EIC.
All as per item No.97 above but shifting of AC from existing location to new location including making good of old location all as specified and directed by EIC.
M & L for taking down Corroded body base tray etc of window type air conditioners and replacement of body base tray etc out of 18 SWG and other portion with MS sheet 20 SWG including motor mounting frame nuts and bolts suitable size painting and necessary insulation complete for 1.0 / 1.5 / 2.0 Ton capacity Air conditioner.(Note : For dismantling compressor for body work and reassembling shall be inclusive in quoted rate)
M & L for preparation of old painted surfaces of Refrigerator any capacity by complete scraping old painting an applying two coat of synthetic enamel painting on outer surface (spray painting) as per existing colour and black colour on bottom portion such as compressor etc. over a coat of red oxide primer complete all as specified and directed.
M & L for preparation of old painted surfaces of Water cooler any capacity by complete scraping old painting an applying two coat of synthetic enamel painting on outer surface (spray painting) as per existing colour and black colour on bottom portion such as compressor etc. over a coat of red oxide primer complete all as specified and directed.
Supply, install, test & commissioning new compressor sealed reciprocating type suitable for window/split type AC 1.5 Ton capacity duly charged with fresh Refrigerant gas etc. complete all as specified & directed by Engineer-in-charge including taking out old . Make : Voltas/usha Shriram/Bluestar /samsung/Hitachi/videocon/LG/Carrier/Daikin etc. as per existing make at site.
All as per item No.102 above but of 2.0 Ton capacity
All as per item No.102 above but of Split type AC 1.5 ton capacity
All as per item No.102 above but of Split type AC 2.0 ton capacity
All as per item No.102 above but of Refrigerator 100/165/180/210 Liters Capacity.
All as per item No.102 above but of Refrigerator 260/280/310/350 Liters Capacity.
All as per item No.102 bove but of Water coolers 40 / 60 /80 Liters capacity
All as per item No.102 above but of Water coolers 120/150/180 Liters capacity
Taking down carefully split type AC of capacity 1.5 / 2.0 ton & refixing on new location complete with pre fabricated brackets/ frame work as required complete & making the good existing surface with out any damage out & indoor unit complete.
supply in fix unserviceable burnt fan motor from window/Split type AC of capacity 1.0 / 1.5 / 2.0 Ton and replacing the same with brand new fan motor of same capacity including connecting up and testing complete.
Supply and fix fan motor suitable for water cooler of any capacity including removing old fan motor and testing complete all as specified and as directed by Engineer-in-Charge .
Supply,fixing and testing fan blade suitable for window AC and split AC of 1.0 / 1.5 / 2.0 Ton capacity including removing old unserviceable fan blade.
Supply and fix in repair of unserviceable contactor for split type AC of any capacity complete all as specified & directed by Engineer-in-Charge.
Supply, fixing and testing fan blade suitable for water cooler of any capacity including removing old unserviceable fan blade.
Replacing old defective blower drum and supply & fix blower drum suitable for window type Air conditioner of 1.0 Ton / 1.5 Ton / 2.0 Ton capacity.
Replacement of front cover grill suitable for window type AC 1.0 Ton / 1.5 Ton / 2.0 /2.5 Ton capacity AC of various makes.
Replacement of starting capacitor 60 - 80 mfd.Make:(ANAND/UNIQUE/ KELTRON)
Replacement of starting capacitor 80-100 mfd.Make:(ANAND/UNIQUE/ KELTRON)
Replacement of starting capacitor 100 -120 mfd.Make: ANAND/UNIQUE/ KELTRON)
Replacement of running capacitor 25 MFD (Make : Asian / Epcos)
Replacement of running capacitor 36 MFD (Make : Asian / Epcos)
Replacement of running capacitor 45 MFD (Make : Asian / Epcos)
Ditto all as per item No.124 above but rotary type
Supply & fix of thermostat switch for window type AC of capacity 1.0 Ton / 1.5 Ton / 2.0 Ton capacity (Make :- Indofoss / Ranutral)
Supply & fix of thermostat switch for split type AC of capacity 1.5 Ton / 2.0/2.5 Ton capacity (Make :- Indofoss / Ranutral)
Supply & fix of thermostat switch for Refrigerator of any capacity (Make :- Indofoss / Ranutral)
Replacement of thermostat switch for Water Cooler of any capacity (Make :- Indofoss / Ranutral)
Taking out old unserviceable and Supply & Fix new over load relay suitable for Window/Split type AC of 1.0 Ton / 1.5 Ton / 2 Ton capacity all as directed.(Make : Arvind / Usha / Ranutrol)
Taking out old unserviceable and Supply & Fix new over load relay suitable for water cooler of any capacity all as directed(Make : Arvind / Usha / Ranutrol)
Taking out old unserviceable and Supply & Fix new over load relay suitable for Refrigerator of any capacity all as directed(Make : Arvind / Usha / Ranutrol)
Supply fixing and clamping jointing copper tubing for suction line and for liquid discharge line duly insulated with suitable insulation material including making hole in wall for passing through and making good to the disturbed surface complete.
Supply and lay cable PVC insulated 3 core 4 Sq mm with copper conductor cable suitable for indoor unit to outdoor unit complete all as directed by EIC
Supply and lay PVC pipe 20 mm dia heavy duty for drain out condensing water of split AC including cutting of floor / opening of hole in wall and making good after laying of pipe etc match the existing surface complete.
S & F push cock / lifting cock of 15 mm bore in repair for water cooler of any capacity
S & F PVC connecting pipe with brass nuts and washers at both ends of length not exc 60 cms for connection of water coolers
S & F GI water tray 2 mm thick for window type AC any capacity with out let system connection provided with PVC pipe of 20 mm dia up to 3 meter length connecting to drain pipe.
Supply & Fix PVC drain pipe with necessary saddles of 25 mm size to be used as out let drain to be fixed all as per direction of EIC
Supply and fix sheet metal enclosure with 2 pin and earth plug and socket complete with single pole MCB of 20 Amps all as specified & directed by EIC.
Taking out old unserviceable and Supply & Fix new magnetic gasket for refrigerator of 165 / 286 / 310 liters complete all as directed by EIC.
Taking out old unserviceable condenser coil of 1.5 Ton window type AC any make with sins cutting in let outlet connecting copper pipe and providing new condensor coil with sins and connecting in let out let copper pipe by brazing, gas charging complete and replacement of nut bolts etc complete all as specified and directed by EIC.
All as per item No. 142 above but for 2.0 ton window type AC complete all as specified and directed by EIC.
All as per item No. 142 above but for 1.5 ton Split type AC complete all as specified and directed by EIC.
All as per item No. 142 above but for 2.0 ton Split type AC complete all as specified and directed by EIC.
Removing electronic unserviceable circuit boards from window type AC 1.5 ton / 2.0 Ton capacity and replacing with new circuit boards and connecting with system with replacing remote control hand set and testing complete all as specified and directed
Ditto all as per item No. 146 above but for 1.5 / 2.0/2.5Ton Split type AC complete all as specified and directed
Supply & Fix blower fan motor capacitor 4 MFD (Make : Asian / Keil)
Supply & Fix blower fan motor capacitor 6 MFD (Make : Asian / Keil)
Supply & fix of electric bulb suitable for refrigerator of any capacity screw type / pin type (Make :- Philips / Equivalent)
Supply & fix of Air filter for window type AC of any capacity and type by EIC.
Supply & fix of Air filter for split type AC of any capacity and type by EIC.
M & L for replacement of damaged outer cover for window type Air conditioner of any capacity and size made out of GI sheet of 20SWG all as specified by EIC.
Taking out existing unserviceable over load protector and Supply & Fix new over load protector for 1.0 /1.5 /2.0 Ton capacity window type Air Conditioner (Make : Usha/ Ranutral).
Supply and fix in repair sensor remote plate(PCB) suitable for 1.5/2.0 Ton capacity split type AC etc. complete all as specified and directed by EIC.
Supply of sensor remote handset suitable for 1.5/2.0 Ton capacity split type AC etc. complete all as specified and directed by EIC.
Supply and fix in replacement suction & liquid line valve of size (5/8"&1/4")/(5/8"&3/8") suitable for split type AC complete all as directed by EIC.
Supply only Refrigerant Gas as per site recruitment
Repair/Replacement of indoor unit of Split type AC 1.5 TR Capacity having 3 star rating complete with all accessories such as installation plate with screws, blower motor, swing motor, filter and PCB etc duly prewired including reconnecting of existing refrigerant piping including gas charging, electrical connections, drain pipe etc and testing after taking out old one complete all as specified and directed. Make- Voltas/Bluestar/LG.
supply and fix in repair outer casing for window type ac of any capacity and any make, of GI/ Aluminum sheet od 20 SWG incl removing of old old existing rusted casing from site
Repair/Replacement of outdoor unit of Split type AC 1.5 TR Cap having 3 star rating complete with all accessories such as hermetically sealed compressor, condenser unit, capacitor, relays, fan motor etc duly prewired including reconnecting of existing refrigerant piping, electrical connections, drain pipe etc and testing after taking out old one complete all as specified and directed. Make- Voltas/Bluestar/LG.
Repair/Replacement of outdoor unit of Split type AC2/2.5 TR Cap having 3 star rating complete with all accessories such as hermetically sealed compressor, condenser unit, capacitor, relays, fan motor etc duly prewired including reconnecting of existing refrigerant piping, electrical connections, drain pipe etc and testing after taking out old one complete all as specified and directed. Make- Voltas/Bluestar/LG.
Supply and fix in replacement multipurpose door lock with duplicate key of refrigerator of any make &capacity etc complete all as specified and directed by EIC.
Taking out old unserviceable cooling coil of window/split type AC any capacity and any make with sins cutting in let outlet connecting copper pipe and providing new cooling coil with sins and connecting in let out let copper pipe by bracing and replacement of nut bolts etc complete all as specified and directed by EIC.
Supply & fix Condensing unit Bracket of any size and type suitable for supporting to out door unit of split type AC including nut, bolts & washers etc complete all as specified and directed by EIC.
BRITE INDUSTRIES
shakti engineering and electrical works
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .