| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.4 LAccepted-AOC R O NAUSHERA DISTT RAJOURI J K 185151 | NAUSHERA | RAJOURI | JAMMU AND KASHMIR | 185151 | L1 | Accepted-AOC Being L1 bidder | |
| 2 | L2₹30.2 L+₹1.3 L (4.45%)Rejected-Finance | L2 | Rejected-Finance Being other than L1 bidder | |
| 3 | L3₹34.6 L+₹5.6 L (19.4%)Rejected-Finance | L3 | Rejected-Finance Being other than L1 bidder |
| Sl No | Description | Qty | Unit | vijay kumar L1 | MEELU ENTERPRISES L3 | Ankit Sagar L2 |
|---|---|---|---|---|---|---|
| 1.00 | Sch 'A' Part-I (B/R Works)
Taking down cement plaster on brick, stone or concrete surfaces including racking out joints hacking for key, scrubbing down with water etc, complete all as specified and directed.
Note: The cost includes any thickness found during execution increased due overleaping of n no of layers of plaster, tiles, mosiac finish with out any cost to Govt exchequer (Contractor shall have no claim on account of form work reqd at site in r/o height of building). | 1,077 | Sqm | 10 ₹10,770 | 1 ₹1,077 Lowest | 20 ₹21,540 |
| 2.00 | Taking down chowkhats or frames with shutters (without taking off shutters from the frames) of size n. exc 1.5 Sqm each complete all as specified and directed.
Note : The rate inlcudes making good of surfaces w/o any extra cost to Govt. | 25 | Each | 50 ₹1,250 | 1 ₹25 Lowest | 100 ₹2,500 |
| 3.00 | Demolition of cement concrete (unreinforced) in ground floors and pavings n. exc 15 cm thickness (below of above GL) and removing out side MD land on contractors own arrangement, complete all as specified and directed.
Note: Demolition includes any no of layers including overleaped tiles , stone etc during execution and no extra cost shall be borne by Govt exchequer. | 94 | Cum | 350 ₹32,900 | 55 ₹5,170 Lowest | 70 ₹6,580 |
| 4.00 | Demolition of brick work built in cement mortar including all quioins, arches, pillars etc complete all as specified and directed. | 17.5 | Cum | 250 ₹4,375 | 5 ₹87.5 Lowest | 100 ₹1,750 |
| 5.00 | Taking down shutter and re fixing same opening after easing and adjusting of steel shutters of any description exceeding 2 Sqm each, complete all as specified and directed .
Note: Any type of reapair such as welding straightinin or any other work reqd to ease shutter is deemed to be included in unit rate. | 8 | Each Leaf | 2,500 ₹20,000 | 1 ₹8 Lowest | 50 ₹400 |
| 6.00 | Dismantling wrought iron or mild steel works of any description and in any position, complete all as specified and directed. | 10.4 | Qtl | 350 ₹3,640 | 55 ₹572 Lowest | 200 ₹2,080 |
| 7.00 | Taking down Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings, complete all as specified and directed. | 322 | Sqm | 20 ₹6,440 | 5 ₹1,610 Lowest | 10 ₹3,220 |
| 8.00 | M&L for Brick work with sub class "B" bricks straight or curved on plan exc. 6m mean radius built in cement mortar 1:6 complete all as specified and directed. | 4 | Cum | 6,000 ₹24,000 Lowest | 8,000 ₹32,000 | 7,500 ₹30,000 |
| 9.00 | All as per Item No 8.00 here-in-before but except Bricks.
Note: Old brick retrieved from demolition shall be used. | 1 | Cum | 6,000 ₹6,000 | 4,000 ₹4,000 | 3,000 ₹3,000 Lowest |
| 10.00 | S&F Factory made MS tubular box type ventilators with of MS rolled steel section conforming to IS-1038 and shall be ISI marked manufacture by ISI approved manufacture,openable frames shall be febricated of section as approved by Engr-in Charge,Glazed, gauged window , mild steel casement stays 300 mm with hinged joint and two plates with studs complete all as specified with all fittings and fixtures without glazing bars, including 3mm sheet glass, stainless steel wire mesh of 0.56 nominal dia and average width of aperature 1.18 mm, etc, complete all as specified and directed. | 17 | Sqm | 6,000 ₹1,02,000 | 4,500 ₹76,500 | 3,000 ₹51,000 Lowest |
Tender Value
₹34.8 L
EMD Value
₹70,000
Closing Date
28 Feb 2026, 6:00 pmClosed
GE 862 EWS
GE 862 EWS PIN-914862 c/o 56 APO
SPECIAL REPAIR TO BLDG NO P-02 AT AP-251 NADPUR AND BLDG NO T-05A T-06A T-07A AND T-14 AT 1/9 GR NARIAN UNDER AGE BR DETT A OF GE 862 EWS
2026_MES_751857_1
GER-94/2025-26
Open Tender
Civil Works
Item Rate
180 days
GE 862 EWS
As per NIT
9 documents required · 9 mandatory
₹500
GE 862 EWS
₹70,000
Yes
27 Mar 2026
7 Feb 2026
3 Mar 2026
7 Feb 2026
28 Feb 2026
22 Feb 2026
Sch 'A' Part-I (B/R Works) Taking down cement plaster on brick, stone or concrete surfaces including racking out joints hacking for key, scrubbing down with water etc, complete all as specified and directed. Note: The cost includes any thickness found during execution increased due overleaping of n no of layers of plaster, tiles, mosiac finish with out any cost to Govt exchequer (Contractor shall have no claim on account of form work reqd at site in r/o height of building).
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) of size n. exc 1.5 Sqm each complete all as specified and directed. Note : The rate inlcudes making good of surfaces w/o any extra cost to Govt.
Demolition of cement concrete (unreinforced) in ground floors and pavings n. exc 15 cm thickness (below of above GL) and removing out side MD land on contractors own arrangement, complete all as specified and directed. Note: Demolition includes any no of layers including overleaped tiles , stone etc during execution and no extra cost shall be borne by Govt exchequer.
Demolition of brick work built in cement mortar including all quioins, arches, pillars etc complete all as specified and directed.
Taking down shutter and re fixing same opening after easing and adjusting of steel shutters of any description exceeding 2 Sqm each, complete all as specified and directed . Note: Any type of reapair such as welding straightinin or any other work reqd to ease shutter is deemed to be included in unit rate.
Dismantling wrought iron or mild steel works of any description and in any position, complete all as specified and directed.
Taking down Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings, complete all as specified and directed.
M&L for Brick work with sub class "B" bricks straight or curved on plan exc. 6m mean radius built in cement mortar 1:6 complete all as specified and directed.
All as per Item No 8.00 here-in-before but except Bricks. Note: Old brick retrieved from demolition shall be used.
S&F Factory made MS tubular box type ventilators with of MS rolled steel section conforming to IS-1038 and shall be ISI marked manufacture by ISI approved manufacture,openable frames shall be febricated of section as approved by Engr-in Charge,Glazed, gauged window , mild steel casement stays 300 mm with hinged joint and two plates with studs complete all as specified with all fittings and fixtures without glazing bars, including 3mm sheet glass, stainless steel wire mesh of 0.56 nominal dia and average width of aperature 1.18 mm, etc, complete all as specified and directed.
S&F guard bars/grills as specified in between glazed and fly proof window shutter(sand witching guard bars/grill) as per drg No CEPZ/TD-325/07 dt 04.12.07, complete all as specified and directed.
S&F 3 mm thick sheet glass ordinary quality and glazing with oil putty in squares n . exc 0.50 sqm in each pane including hacking out old glasses of any description, complete all as specified and directed.
M&L for 75 mm thick Cement concrete type B-2, 1:2:4 (using 40mm graded stone aggregate) in alternate pannel as in floor finished even and smooth w/o using extra cement using surface vibrator, complete all as specified directed. Note: Contractor shall have no claim on account of what so ever incurred in r/o of form work for laying.
M&L for rendering 15 mm thick in cement mortar 1:6 on brick masonry surface or concrete work, finished even and smooth without using extra cement, complete all as specified and directed.
M&L for rendering 15 mm thick in cement mortar 1:4 on brick masonry surface or concrete work, finished even and smooth without using extra cement and WPC, complete all as specified and directed. Note: WPC shall be measured and paid separately.
M&L for rendering 5 mm thick in cement mortar 1:3 on concrete surface of ceiling/facia, finished surface even and smooth without using extra cement, complete all as specified and directed. Note:- No extra cost cost shall be claimed by contractor in respect of formwork/scafolding and at any height and site where plaster is to be executed.
M&L for rendering 10 mm thick in cement mortar 1:4 on concrete surface of fin facia, chajja, roof projection etc, finished surface even and smoothe without using extra cement over and including dubbing out average 10mm thick on irregular face, complete all as specified and directed. Note:- No extra cost cost shall be claimed by contractor in respect of formwork/scafolding and at any height and site where plaster is to be executed for Ser item No 14 to 17 above).
M&L for providing 75mm cement concrete, type C-2, 1:3:6, (using 40mm graded crushed stone aggregate) as in plinth protection, laid in slope 1:12 from outer edge of the wall, finished even and fair, laid in alternate bays including providing 6mm wide joints throughtout thickness of plinth protection in concrete bays and in between walling and plinth protection, joints filled mastic filling comprising of one part of heated bituminous 85/25 and 3 parts of sand (all by weight), complete all as specified and directed.
M&L for cement concrete (1:2:4) type B-0 using 12.5mm stone aggregate as in levelling course, benching kerbs of mud stops, rounded or chamfered on edges, fillings of hollow portion of door frames including form work, complete all as specified and directed.
M&L for cement concrete type B1 1:2:4 (using 20 mm graded crushed stone aggregate) in PCC blocks for holdfasts, benching, coping and the like including weathering, slightly rounded or chamfered angles, complete all as specified and directed.
M&L for cement concrete type B-1, 1:2:4 (using 20 mm graded stone aggregate) 25 mm thick as in levelling course sloped for recieving roof treatment, complete all as specified and directed.
Erection and Refixing of Roof trusses (framed), trussed, purlins, Rafter .crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc, complete all as specified and directed.
S & F Stairs (framed) including stringers, treades, landing, balusters, hand rails etc. including cleats, brackets, etc, complete all as specified and directed.
S&F Pre-painted coloured, galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm in colour pattern (multi colour pattern as approved by GE) having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and directed.
S&F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm in colour pattern (multi colour pattern as approved by GE) having tensile strength of 550Mpa as in ridge, cladding to wall, fixed with self tapping screws, complete all as specified and directed.
S&F in repair 1.25 mm thick Mild steel, plain, black sheet in wall cladding, eaves gutters, and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles and making provision for funnel shape at site, etc. as required, complete all as specified and directed.
Supply only Integral water proofing compound conforming to IS, complete all as specified and directed.
S&F 100 mm bore Cast iron rainwater socketed pipes with cement joints, with ears, complete all as specified and directed.
S&F 100 mm bore Cast iron Bends or elbows, square, or obtuse for rainwater socketed pipes, complete all as specified and directed.
S&F 100 mm bore Stack clamps out of 50 mm by 5 mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof, complete all as specified and directed.
M&L for heavy vuty reinforced acrylic coating for terrace water proofing (Make Dr Fix It / Sikka / Texa Ind Ltd ) over a coat of Primmer for Sealer coat (Dr fix it) with roller, complete all as specified and directed.
M&L for water proofing treatment on non approachable / non accessible roof surface horizontal and vertical surfaces in following sequence through manufacturer / authorized applicator of the manufacturer, complete all as specified and directed.:- (i) Taking down/removing existing treatment and cleaning properly with wire brushing etc, rabish off from the premishes. (ii) 10mm thick plastering on roof surfaces in cement mortar 1:4 mixed with water proofing compound as per manufacturers instructions. (iii) After drying concrete surfaces and apply a coat of bituminous primer @ 0.40 Kg/Sqm on the prepared surface of roof. (iv) After the primed surface has dried, apply a coat of hoat blown bitumen 85/25 or equivalent viscosity grade @ 1.2 Kg /Sqm of the surfaces etc complete. (v) Laying unrolled over the bitumen coated surfaces polymeric water proofing membrane, of approved make standard weight not less than 3 Kg / sqm with 100 mm over laps shall be sealed by flame as per manufacturer instruction. (vi) Applying a coat of hot air blown grade bitumen of grade 85 / 25 @ 0.5 Kg / sqm duly sanded over polymeric membrane complete. (vii) provide final layer of two coats of aluminium paint over a coat of primer as per manufactue instructions.
M&L for applying one coat of “ Rust Remover” (Dr Fix it Rust removing chemical) or “Defroster” or equivalent chemical as approved to old rusted reinforcement after necessary preparation of surfaces by brush application, complete all as specified and directed.
M&L for bonding the entire exposed surface with one coat of “Fosroc Ntobond SBR” as per manufacture instruction, complete all as specified and directed.
M&L for applying one layer of Fosroc spray shotcrete concrete 20 mm to 25 mm thick (comprises composition 1:2:1 plain cement concrete i.e. one part of cement two parts of fine aggregate and one part of 10 mm and down size trap stone aggregate) mixed with spray set SL 2 to 2.5% weight of cement and 12.5 to 16.5 liters of water mixed as per manufacture instructions and gunniting pressure nozzle with a delivery capacity of 2.5 kg per sq m over column, beam, roof slab and other similar work, complete all as specified and directed. Note:- Contractor shall provide the even surface (with out any extra cost to govt ) duly floated and clearence from wall floor or site damaged due to splashing of cement grouts.
M & L for Dubbing out average 20mm thick CM 1:4 on irregular face of old walls/ ceiling, fin facia chajjas etc, complete all as specified and directed.
M&L for post anti-termite treatment to Treatment of soil under existing floors using emulsion @ one litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement: 2 coarse sand) to match the existing floors, complete all as specified and directed.
M&L for post anti - termite treatment to Treatment of soil Along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc. in apron, complete all as specified and directed.
M & L for preparation of newly plastered surfaces of walls and applying three coats of white wash complete all as specified and directed.
M & L for preparation of newly plastered surfaces of ceiling and applying two coats of white wash complete all as specified and directed.
M & L for preparation of old plastered surfaces of wall and applying one coat of white wash complete all as specified and directed.
M&L for preparation of new plastered wall surface and applying two coats of exterior weather proof paint (multi colour pattern as approved by GE) over a coat of alkali reistant primer, complete all as specified and directed.
M&L for one coat of Black paint for writing letters on surfaces of any description wood, steel, iron, concrete, brick, stone etc exc 10 cm width or girth, complete all as specified and directed.
M&L for re-writing and repainting of letter or figures (Block, Roman, Italic or Indian) n exc 30 cm high with synthetic enamel paint of any colour, complete all as specified and directed.
M&L preparation of new or previously untreated steel or iron surfaces of any description over 10 cm width or girth not otherwise described and applying two coats of Synthetic enamel paint over a coat of red oxide primer, complete all as specified and directed.
M&L for preparation of old steel surface and applying one coat of synthetic enamel paint, complete all as specified and directed
M&L for 100 mm thick Cement concrete type E- 2, 1:5:10 (using 40mm graded stone aggregate) as in sub base of floors,Pavings complete all as specified and directed .
M&L for 25 mm thick Sand filling under floors or in foundation including watering and consolidation for laying interlocking tiles, complete all as specified and directed.
M&L for Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 80mm thickness, M-40 Grade, set and joint filled with sand, complete all as specified and directed.
Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required, complete all as specified and directed.
Demolition of cement concrete of any description and in any position not otherwise specifically provided for, complete all as specified and directed.
Dismantling wall and ceiling boards (fibre, pulp, insulation etc) or insulaton boards/slabs/blankets, any thickness, including cover fillets, complete all as specified and directed.
Dismantling of timber scantling, in fillets, rails, posts, rafters, purlin, etc under 40 sq.cm in section, complete all as specified and directed.
Dismantling of timber scantling 40 sqcm and over in section fixed to any position as in unframed work. complete all as specified and as directed.
Taking down chowkhats with shutter (without taking of from shutter) exc 1.5 sqm and n exc 4 sqm each and removing to store and making good to surface disturbed due taking down, complete all as specified and directed.
M & L for mild steel TMT bars 10mm dia and over, cut to length, bend to shape required, including cranking ,bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips, complete all as specified and directed.
All as per Item No 56.00 here-in-beofre, but 5 mm dia and over upto and including 10 mm dia in stirrups, spacers and binders.
M&L for formwork to sides and soffits of floor or roof beam, beam hunching, girders, lintel, cantilevers, shelves including suports, overhangs etc, complete all as specified and directed.
M&L for RCC (1: 2 :4) type B-1 (using 20mm gradded stone aggregate) as in beams, deck slabs, chajjas and in shelves and like, complete all as specified and directed.
M&L for stone walling of random rubble masonry, uncoursed, well bonded, bedded and soilidly hearted, built in cement mortar (1:6), complete all as specified and directed.
All as per item No 60.00 here-in-before but except stone.
M&L for extra over stone walling of any type of stone for hammer dressing to face stones and dressing of face beds with maximum depression on face from straight edge held against the dressed surface n exc 40 mm and joints, as specified, of random rubble walling, uncoursed or brought upto courses, complete all as specified and directed.
S&F rolled section as in main and cross beams, hip and jack rafters, purlins, vertical post where connected to common rafters and running rails and guides for sliding gates, doors fixed with angle cleats or other connecting plates, complete all as specified and directed.
S&F Mild steel screw bolts exc 5 cm length not exc.10 cm length(machine made) with hexagonal or square heads at one end and screwed the other , or screwed both ends , each screwed end to be fitted with washers and one hexagonal or square dia of shank 11 to 15mm, complete all as specified and directed.
S&F Mild steel holding nut bolts exc 22.5 cm length not exc.30cm length(machine made) with hexagonal or square heads at one end and screwed the other , or screwed both ends , each screwed end to be fitted with washers and one hexagonal or square dia of shank 11 to 15mm, complete all as specified and directed.
S&F (plain or chequered) channels, square cut or notched (oridinary and counter sunk) forming holes, w/o any attatchment, complete all as specified and directed.
M&L for rendering 20mm thick in cement mortar (1:4) on stone masonry surface, finished even and smooth without using extra cement, complete all as specifed and directed. Note:- No extra cost shall be borne by Govt exchequer for any scaffolding and for any height.
M&L for rendering 20mm thick in cement mortar (1:6) on stone masonry surface, finished even and smooth without using extra cement, complete all as specifed and directed. Note:- No extra cost shall be borne by Govt exchequer for any scaffolding and for any height.
S&F 1.25 mm thick pressed steel frame 125x60mm for doors with one or more rebates incl supplying and fixing necessary fixing lugs, hinges lock strike plate etc, complete all as specifed and directed.
S&F Plain framed, panelled shutters (any number of panels) with pannel of timber flat on both sides (feather edged) or of veneered particle board with commercial face veneers 35 mm thick 2nd class hard wood supplied and fitted to chowkats, complete all as specifed and directed.
M&L for 35 mm thick second class hardwood glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc, (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitered beads for securing glass, etc, size of members of shutter as specified in SSR Part-I, Section 8, clause 8.20 (a), fitted to chowkats, complete all as specifed and directed.
S&F in repair 300mm MS ordinary rat tail rod pattern door springs (ISI marked) of approved make including roller and roller plate, complete all as specified and directed.
S&F Stainless Steel wire cloth 0.36 mm any position nominal dia of wire and 1.2 mm average width of aperture fixed with tinned tacks or galvanised wire staple, complete all as specifed and directed.
S&F for aluminium alloy handles size 150 mm fabricated type anodised (ISI marked), complete all as specified and directed.
S&F for aluminium anodized barrel tower bolts 150 mm long of extruded section (ISI marked) ,complete all as specified and directed.
S & F 250 mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy, complete all as specified and directed.
S&F 16-18mm thick machine cut kota stone slab (area of each slab nexc 0.27 Sqm except space constraint) in flooring laid and jointed with gry cement slurry Mixed with pigment to match the shade of the slab incl rubbing and mirror polishing as in repairs over and including 15mm thick screed bed in CM 1:3 complete incl roughening the surface and dismantling of old kota stone slabs, complete all as specifed and directed.
All as per Item No 77.00 here-in-before but as in riser to steps, skirting, dado,window cills fixed over and including 15mm thick rendering in CM 1:4.
S&F vetrified ceramic tiles in light shade of size 600x600x10 mm thick as in floor set and jointed in neat cement slurry and pointing in white or coloured cement to match the colour of tiles over and including 15mm thick screed bed in CM 1:4, complete all as specifed and directed.
All as per item No 79.00 here-in-before but in skirting/dado over and including 10mm thick render in CM (1:4).
S&F in repair for Curtain Rod of stainless steel 25 mm dia fancy type complete and hanging hooks/brackets / end caps of length 1.5 mtr to 1.8 mtr, complete all as specifed and directed.
M&L Providing & fixing of 4mm thick designer ceiling board (Make : Everest/Ramco/) in ceiling fixed with screw as per manufactures instructions, laid on hot dipped galvanized iron imposed grid with 24mm wide T-section exposed flanges which shall be powder coated white. The frame work shall comprise of main runner made from 0.33mm thick galvanized steel sheet & of size 24x32x300mm and spaced at 12mm centres securely fixed to the structural soffits by approved hangers at 1200mm maximum centres. Hangers of GI wire 4mm dia to be fixed by approved rowl plug, level adjusters and screws etc. The last hanger at the end of each main runner shall not be greater than 450mm from adjacent wall flush fitting of 1200 long cross tee with (double stitching) to be inter locked between main runners at 600mm centre to from 1200x600mm modules cross tee longer than 600mm modules to be formed by fitting 600mm long cross tee, tee perimeter wall angle shall be of 0.45mm thick galvanized steel of size 19x19mm and 300mm long of white colour all as per instruction, complete all as specifed and directed.
M&L for preparation of new plastered surface of walls and applying two coats of oil bound distemper, complete all as specifed and directed.
M&L for preparation of old surface of walls and applying one coat of oil bound distemper, complete all as specifed and directed.
M&L for preparation of newly plastered surfaces of wall and applying two coats of cement base paint over a coat of primer, complete all as specifed and directed.
M&L for preparation of old surfaces of wall and applying one coat of cement base paint, complete all as specifed and directed.
M&L for preparation of old painted steel or iron surfaces of any description over 10 cm width or girth not otherwise described and applying one coat of Synthetic enamel paint, complete all as specifed and directed.
M&L for applying two coats of synthetic enamel paint over a coat of pink primer on new or previously untreated wood and wood based surface including preparation, complete all as specifed and directed.
M&L for applying one coat of synthetic enamel paint over on old wood and wood based surface including preparation, complete all as specifed and directed.
M&L for chequered cement concrete tiles of size 30cmx30cmx25mm thick set and jointed and pointed in neat cement slurry as inpath, pavings with gray cement and no pigment over and including screed bed or bedding layer of mortar 20 mm thick for laying floor tiles in CM 1:4, complete all as specified and directed.
M&L for PCC 1:3:6 type C1 (using 20mm graded stone aggr) as in surface channels and drains incl all necessary form work, complete all as specified and directed.
Extra forming fair finished drain or channels 30cm inner girth in cement concrete using extra cement including forms, mould, mitred/stopped ends etc, complete all as specified and directed.
Sch 'A' Part-II (E/M works) S&F in repair single pointed Air Termination, single pointed, copper rod 12mm dia and 300mm long, complete all as specified and directed.
M&L for steel tubular swaged poles errected to truly vertical position with 6mm thick mild steel base plate of size 300mm x 300mm, welded to Pole, B-118 finial taper plug, bolts, nuts and screws, poles made out of REW MS tubing confirming to IS-2713, Part-II, type 410-SP-31 (9m long) including drilling of holes of required size for fixing of cross arms/ lightning conductor and painting the exposed surfaces of pole with two coats of aluminium paint over a coat of red oxide zinc chrome primer and two coats of black bituminous paint internally and portion embedded in concrete, making five black and white bands at lower portion of pole each 300mm wide at 300mm spacing alternately and marking pole number with black paint at suitable height including taking down old unserviceable broken PCC pole of 9mtr long, complete all as specified and directed.
M&L for PCC 1:4:8 (nominal mix) type D-2 (using 40mm graded crushed stone aggregate) as in foundation filling and mass concrete of poles and stay/ installation paths, complete all as specified and directed.
M&L for PCC type C-1, 1:3:6 (using 20mm graded stone aggregate) as in poles, foundation including necessary form work, complete all as specified and directed.
Excavation in trenches not exceeding 1.5 mtr wide and not exc 1.5 mtr depth for laying of cables, pipe lines, protection pipes and foundations etc and getting out in soft/ loose soil, complete all as specified and directed.
All as per Item No 97.00 here-in-before but exc 1.5 mtr and n. exc 3m in depth.
Removing excavated soil not exc 50 mtr ant depositing where directed at a level not exc 1.5 mtr above the starting point, complete all as specified and directed.
S&F in repair of test point, terminal block made out of gun metal or phosphorous bornze of size 75mm x 75mm 25mm, drilled and screwed with 3 Nos, 8mm dia 25mm long hexagonal head screw housed in FRP box duly locking arrangement including connecting down conductor and earth strip including removal of old unserviceable all, complete all as specified and directed.
S&F in repair of aluminium strip 25x3mm for roof and down conductor on any type wall surface with necessary fixing arragement by providing porcelain base at 60cm interval and using cadmium plated fixing screws and insulators per running meter including removal of old unserviceable all, complete all as specified and directed.
S&F in repair tubes light grade, galvanised with all fitting of dia 40mm, jointing errecting the pipe for lightening protection at any height with flat angle support to base, complete all as specified and directed.
Taking down unserviceable aluminium point wiring (light, fan, socket or power) complete, including all fitting and fixtures such as switches, ceiling roses, pendants, regulators sockets, light fittings etc.) removing material for taking credit (credit for above items should be made as per conditions separately) and making good the disturbed, complete all as specified and directed.
M&L for point wiring for following types of electrical points with two runs of FRLS PVC insulated unsheathed 1100 Volts, grade multi stranded copper conductor of size 1.5 sqmm drawn through medium grade PVC conduit pipe not less than 20mm dia concealed in wall/ surface in ceiling incluidng provn of pressed steel terminal boxes suitable size of 2.8mm thickplastic laminated sheet cover for mounting switches, sockets, fan regualrors etc with necessary screws and 1.5 Sqmm. (nominal area) single core FRLS, PVC insulated 1100 Volts, grade multi stranded unsheathed copper conductor cable as earth wire upto common earth and connected to earth dolly including making good the diturbed surfaces to match with the existing, complete all as specified and directed as per following:- Note: Cost of cutting chasing and making good to disturbed surface to match with existing surface are deemed to be included in quoted rate.
One light point/ fan point controlled by one switch, one way
One socket outlet 5 Amp, point controlled by one switch one way on same switch board.
One switch socket outlet 5 Amps point controlled by one switch one way on independent switch board.
All as per item No 104.00 here-in-before, but point wiring 2.5 sqmm for socket outlet 15Amps point controlled by one switch.
S&F for switch piano flush type 6 Amps, one module, one way 230 volts, complete all as specified and directed.
S&F for switch piano flush type Single Pole, 15 Amps, one way 230 volts, complete all as specified and directed.
S&F for socket outlet 5 Amps, 3 Pin, 2 in 1, flush type, suitable for 230 volts, complete all as specified and directed.
S&F for socket outlet 5/15 Amps, 3 Pin, 2 in 1, flush type, suitable for 230 volts, complete all as specified and directed.
M&L for ceiling rose surface bakelite 3 terminals, PVC/ Polycarbonate, isolated body, complete all as specified and directed.
S&F in replacement of stepped type elctronic fan regulator 120W, 2 module, heavy duty flush type, complete all as specified and directed.
M&L in replacement for LED Tube light fitting, complete with 1x 20 watts, 220V, AC decorative box type with driver, holder in and including LED tube light connection complete prewired and connecting electrically to ceiling rose to fitting using PVC insulated and overall sheathed flexible copper conductor cable of size 0.75 sqmm 3 core and connector block etc and necessary fixing arrangement at any height, complete all as specified and directed.
S&F in replacement lamp holder insulated body PVC/ Polycarbonate type with back plate suitable for batten/ angular/ pendent fittings, complete all as specified and directed.
S&F LED lamp 7/9 watt suitable for lamp holder, complete all as specified and directed.
S&F in replacement sheet metal enclosure MCB DB, SPN 240 volts 4 way with IP-43 IK-09 protection double door 200A complete with appropirate size bus bar and neutral link, fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specificaiton, complete all as specified and directed. Note: MCBs will be measured separately.
S&F in replacement of MCB SP 240 volt any rating from 6 to 40 Amps conforming to IS 8828 of 1996, with rupting capacity 10KA including providing thimble for out goint cable complete all as specified and directed.
S&F in replacement of MCB SPN 240 volt any rating from 6 to 40 Amps conforming to IS 8828 of 1996, with rupting capacity 10KA including providing thimble for out goint cable complete all as specified and directed.
Supply and Fixing in replacement 1100 volts grade heavy duty cable PVC insulated aluminium conductor served with inner sheathing of PVC tape and overall PVC sheathed in service connection suspended by insulating hangers not more than 1 mtr apart including 4sqmm suspension wire, one twin core cable, flat or circular of size 6sqmm, complete all as specified and directed.
S&F in replacement bulk head luminaries with 1 x 9/10 watt bulk head luminaries LED light driver holder etc complete with all accessories and including connecting up with three core flexible copper conductor cable of suitable size, complete all as specified and directed.
M & L in replacement for earthing with galvanised steel earth plate electrode 600mm x 600mm x 6 mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate vertically to a depth not less than 1.5 mtr below normal ground level, connecting to 25 x 4mm thick GI strip as earth lead by means of bolts, nuts, check nuts and washers of galvanised iron strip protected by provision of GI light grade pipe 40mm dia including provision of concrete pit made from PCC (1:2:4) type B-1 (using 20mm graded stone aggregate) with 40mm thick cover of RCC (1:2:4) reinforced with XPM (weight not less than 4Kg/Sqm) and frame of angle iron 25 x 25 x 6mm with lugs 02 Nos and with 6mm dia MS bar handle made to shape, GI medium grade 20mm bore pipe for watering perforated at bottom, 1.75mtr long placed on top edge of earth plate, common salt & charcoal filling, test point made out of 17mm x 8mm FI with fixing arrangement, funnel, wire mesh and earth work in hard/ dense soil, returning filling in and removal of surplus soil to a distance not exceeding 50mtr, all as per electrical plate No 5 of SSR Part-I, connected to earth test point all as specified or indicated including testing on completion, complete all as specified and directed.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.37 MB
TD.pdf
Tender Documents • 1.02 MB
BOQ_842092.xls
BOQ • 0.45 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .