| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.5 LAccepted-AOC RZ H 5 NANDA BLOCK MAHAVIR ENCLAVE PART 1 PAL AM SOUTH WEST DELHI DELHI 110045 | SOUTH WEST DELHI | DELHI | 110045 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹13.1 L+₹77,462 (6.30%)Rejected-AOC RZ 1 7 167 GALI NO 6 DURGA PARK NASIRPUR SOUTH WEST DELHI DELHI 110045 | SOUTH WEST | DELHI | 110045 | L2 | Rejected-AOC Rejected | |
| 3 | L3₹15.2 L+₹2.8 L (23.2%)Rejected-AOC 3788 SHAH GANJ GB ROAD NEW DELHI 110006 | NORTH | DELHI | 110006 | L3 | Rejected-AOC Rejected | |
| 4 | L4₹15.7 L+₹3.4 L (27.4%)Rejected-AOC | L4 | Rejected-AOC Rejected | |
| 5 | L5₹20.0 L+₹7.7 L (62.3%)Rejected-AOC | L5 | Rejected-AOC Rejected |
Tender Value
₹24 L
EMD Value
₹48,000
Closing Date
1 Mar 2022, 6:00 pmClosed
GE (P) AF GUrgaon
GE (P) AF Gurgaon Near Atul Kataria Chowk Gurgaon
GE (P) AF/GUR-78/2021-22 REPAIR/REPLACEMENT OF INTERNAL ELECTRIFICATION, CEILING FANS, EXHAUST FANS AND OTHER CONNECTED ITEMS IN MD ACCN IN SEKHON VIHAR AT AF STN PALAM UNDER GE (P) AF GURGAON
2022_MES_505101_1
GE (P) AF/Gur-78/2021-22
Open Tender
Miscellaneous Works
Item Rate
180 days
GE (P) AF Gurgaon
All as per NIT
10 documents required · 10 mandatory
₹500
GE (P) AF Gurgaon
₹48,000
Yes
12 Mar 2022
1 Feb 2022
3 Mar 2022
1 Feb 2022
1 Mar 2022
15 Feb 2022
Amount
Taking down carefully point wiring of any type, size and description (light, fan, socket outlet etc.) including removal of battens, pipes, sockets, switches, ceiling roses, light fittings etc, complete and making good the disturbed surfaces to match with existing, all as specified and as directed.
Taking down main switches, distribution boards etc of any type and capacity along with the existing boards, and removing the same from site and making good the disturbed surfaces/portion of walls etc. all as directed.
Taking down old and unserviceable sub main wiring of any size and description and removable the same from site and making good the disturbed surfaces/portion of walls etc. all as directed.
M&L for concealed sub main wiring of two run with 04 Sqmm single core PVC insulated, FRLS, flexible multi stranded copper conductor cable 1100 volts grade, drawn through and including PVC conduit pipe 25 mm dia medium grade and accessories of suitable size and fixed on concealed surface of wall/ceiling with cutting chases for conduit including one run of 4.0 Sqmm single core PVC insulated, FRLS , flexible multi stranded copper cable as earth continuity conductor in green color all as specified and as directed.Note- (a) Two runs of single core cable with one run of earth continuity cable including PVC conduit and its accessories will be measured and paid as one unit.(b) Make disturbed surface good to wall/floors .
M&L for concealed sub main wiring of two run with 06 Sqmm single core PVC insulated, FRLS, flexible multi stranded copper conductor cable 1100 volts grade, drawn through and including PVC conduit pipe 25 mm dia medium grade and accessories of suitable size and fixed on concealed surface of wall/ceiling with cutting chases for conduit including one run of 6.0 Sqmm single core PVC insulated, FRLS , flexible multi stranded copper cable as earth continuity conductor in green color all as specified and as directed. Note- (a) Two runs of single core cable with one run of earth continuity cable including PVC conduit and its accessories will be measured and paid as one unit.(b) Make disturbed surface good to wall/floors .
M&L for sub main wiring complete using 2 run of 10 sqmm and one run of 10 sqmm, PVC insulated unsheathed FRLS multistranded copper conductor ISI marked 1100 Volt grade including concealed PVC conduit of medium grade ISI marked with accessories, through wall/ceiling including taking down and making good existing surfaces, complete all as specified and as directed by Engr-in-charge.
M&L for sub main wiring complete using Four run of 16 sqmm and one run of 16 sqmm, PVC insulated unsheathed FRLS multistranded copper conductor ISI marked 1100 Volt grade including concealed PVC conduit of medium grade ISI marked with accessories, through wall/ceiling including taking down and making good existing surfaces, complete all as specified and as directed by Engr-in-charge.
M&L for sub main wiring complete using Four run of 25 sqmm and Two run of 25 sqmm, PVC insulated unsheathed FRLS multistranded copper conductor ISI marked 1100 Volt grade including concealed PVC conduit of medium grade ISI marked with accessories, through wall/ceiling including taking down and making good existing surfaces, complete all as specified and as directed by Engr-in-charge.
M&L for sub main wiring of two run with 04 Sqmm single core PVC insulated, FRLS, flexible multi stranded copper conductor cable 1100 volts grade, drawn through and including PVC casing-n-coping of size 25 x 16 mm medium grade and accessories of suitable size and fixed on wall/ceiling including one run of 4.0 Sqmm single core PVC insulated, FRLS , flexible copper cable as earth continuity conductor in green color all as specified and as directed.
M&L for sub main wiring of two run with 06 Sqmm single core PVC insulated, FRLS, flexible multi stranded copper conductor cable 1100 volts grade, drawn through and including PVC casing-n-coping of size 25 x 16 mm medium grade and accessories of suitable size and fixed on wall/ceiling including one run of 6.0 Sqmm single core PVC insulated, FRLS , flexible copper cable as earth continuity conductor in green color all as specified and as directed.
M & L for concealed point wiring complete with FRLS PVC insulated /unsheathed stranded copper conductor of wire 1.5 Sqmm , 1100 volt grade , alongwith one single core of same size stranded copper as continuous earth wire to common earth dolly in and including PVC conduit pipe fitting medium grade of 20 mm dia fixed in concealed surface of wall/ceilling/false ceilling including cutting /chasing in wall as required with powder coated sheet metal terminal boxes of required sizes and thickness (factory made) sunk in wall only with 3.0mm thick laminated sheet where as required and accessories complete suitable for the following :-
One light/fan point controlled by one on way switch
One socket outlet 05 Amps on the same board
One socket outlet 05 Amps on independent board
One bell/buzzer point controlled by on bell push
One light point controlled by two 2- way switches with cables 1.5 sqmm size.
-Ditto- as per item No. 11 above but point wiring with 2.5 Sqmm cable and 2.5 Sqmm earth continuity conductor for 3 pin 15 Amp socket and all as specified and directed.
M&L for point wiring complete with 1.5 Sqmm single core PVC insulated and unsheathed multi stranded copper conductor cable 1100 volt grade, (FRLS) through and including 20X12 mm PVC casing-n- copping and its accessories, cadmium screws and including 1.5 Sqmm single core PVC insulated and unsheathed multi stranded copper conductor cable(FRLS) as earth continuity conductor and MS boxes made of 16 gauge MS sheet concealed type on walls cover 3mm thick for housing the specified and directed for the following :-
One light/fan point controlled by one on way switch
One socket outlet 05 Amps on the same board
One socket outlet 05 Amps on independent board
One bell/buzzer point controlled by on bell push
-Ditto- as per item No. 13 above but point wiring with 2.5 Sqmm cable and 2.5 Sqmm earth continuity conductor for 3 pin 15 Amp socket and all as specified and directed.
Attending complaints related to internal electrification including replacement & minor repairs like reconnections, replacement of screw/washers any type & size, insulation tape replacement etc and obtaining completion of user on complaint slip, complete all as specified and as directed by engineer-in-charge. Contractor shall attend the complaints on requirement bases from 0900 to 1730 hours on working days including on non-working day also if required for that contractor shall deploy at least 02 semi skilled Electrician and one helper at Sekhon vihar residential complex (10 Blocks 10 storey bldg total 400 Officer+ 400 Servant Qtrs) for Day to day on all working day.The cost of said electricians and helpers shall be included in cost of attending complaints under this item and No extra payment on this account shall be given to the contractor.
S&F in replacement SPN 2 way sheet metal enclosures for flush/surface mounting distribution board Single door, 240 volts without bus bar complete all as specified and directed.
S&F in replacement SPN 4 way sheet metal enclosures for flush/surface mounting distribution board single door, 240 volts factory made and tested complete, suitable for mounting MCBs with 200 Amps rated bus bar, cable lugs complete all as specified and directed
S&F in replacement TPN 8 way sheet metal enclosures for flush/surface mounting distribution board single door, 415 volts factory made and tested complete, suitable for mounting MCBs with cable lugs complete all as specified and directed
Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to 25x4 mm galvanised earth strip by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 5 connected to earthing test point including testing on completion and all excavation and earth work including taking out existing complete all as specified & as directed .
Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 5 connected to earthing test point all as specified or indicated including testing on completion and all excavation and earth work including taking out old complete all as specified & as directed .
Taking down ceiling fan / exhaust fan / wall mountd fan any sweep from sealing cable end, dismantling blades and removing fan and blades to store and reassembling and refixing the fan after repairing/servicing complete all as specified and directed.
M&L for opening ceiling fan any type & any sweep, cutting the burnt winding, rewinding with super enamelled copper wire as per existing size and gauge with and including provision of insulating material varnishing with good quality varnish including replacement of all unserviceable parts such as safety pin, fan clamp with rubber bush,bearings and twin core flexible copper wire etc complete all as specified and as directed by Engr-in-charge.
M&L for opening Wall fan any type, any make and of any sweep, cutting the burnt winding, rewinding with super enamelled copper wire as per existing size and gauge after providing all required insulating material varnishing with good quality varnish including replacement of all unserviceable minor parts such as safety pin, bearings, rotary switch with thread complete all as specified and as directed by Engineer-in-Charge.
M&L for opening of 400/450 mm sweep exhaust fan any type and any make cutting the burnt winding, rewinding with super enamelled copper wire as per existing size and gauge after providing all required insulating material varnishing with good quality varnish including replacement of all unserviceable minor parts such as safety pin, bearing, bush and capacitors complete all as specified and as directed by Engineer-in-Charge.
Note for Ser item Nos. 22.00 to 24.00 :- Replacement of any parts like capacitor, condensor, ball bearing, bushing and alike will be measured and paid seperately and rate also includes for cleaning, greasing, providing machine made screw, split pin etc alike complete.
M&L for painting to ceiling fan/Exhaust fan any sweep complete, in-situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc.complete.
Supply & Fix ventilating fan of PVC body type 200mm sweep complete all as specified and as directed by Engineer- in Charge. Make:- BAJAJ/ ORPAT/Philips
Supply Fix Wall fan PVC body type 300mm sweep complete all as specified and as directed by Engineer- in Charge. Make:- BAJAJ/ ORPAT/Philips
Supply Fix Ceiling Fan 1200mm sweep 3 blade single phase 5 star energy rating 230V 50 Hz complete with all accessories complete all as specified and as directed by Engineer- in Charge. Make:- BAJAJ/ ORIENT/ Philips
Supply & Fix Kitchen exhaust fan 300mm sweep metal body with front grill complete all as specified and as directed by Engineer- in Charge. Make:- Bajaj/ORPAT/ Philips
Supply & Fix in replacement of louvers for metal body 300 mm sweep exhaust fan for kitchen as per matching to existing complete all as specified and as directed by Engineer- in Charge.
Supply & Fix in replacement of copper wound Fan motor for exhaust Fan metal body 300mm sweep complete as per matching to existing type and gauge complete all as specified and as directed by Engineer- in Charge.
Supply & Fix in replacement of copper wound Fan motor for Ventilating Fan PVC body 200mm sweep with front lock & capacitor complete as per matching to existing type and gauge complete all as specified and as directed by Engineer- in Charge.
Supply and fix down rod 12mm dia made out of high density mild steel 300mm long as per approved sample.
M&L in replacement of nut and bolt (not less than 2.5 inches) and 0.25 inches dia with suitable size rubber reel for hanging of ceiling fan complete all as specified and directed.
M&L in replacement of PVC canopy of any size and shape suitable for existing ceiling fan make complete all as specified and directed.
M&L in replacement of blades of 1200mm sweep made of aluminium sutiable for ceiling fans complete all as specified and directed.
M&L in replacement of louvers suitable for 400/450 mm sweep exhaust fan complete all as directed.
Supply and fixing in replacement of fan stator with copper winding as per sample and make the ceiling fan serviceable all as specified and directed
Supply and fixing in replacement of fan stator housing with bearing as per sample and make the ceiling fan serviceable all as specified and directed
Supply and fixing in replacement of ceiling fan hanging clampwith rubber bush complete as per sample all specified and directed
M&L in replacement of metal flush box for fixing of switches for 1/2/3 module as per sample including all finishes all as specified. Make : Simon or equivalent as approved.
M&L in replacement of metal flush box for fixing of switches for 4 module as per sample including all finishes all as specified. Make : Simon or equivalent as approved.
M&L in replacement of metal flush box for fixing of switches for 6 module as per sample including all finishes all as specified. Make : Simon or equivalent as approved.
M&L in replacement of metal flush box for fixing of switches for 8 module as per sample including all finishes all as specified. Make : Simon or equivalent as approved.
Supply and fixing hylam sheet round corner of size as required at site, complete all as specified and as directed by Engr-in-Charge. Note:- cost of cuttung of hylam sheet is deemed to be fit in the quoted amount
M&L for opening and cleaning of existing kitchen exhaust fan including blades of any type any make with oil and dirt removing solution and refixing back to existing location complete all as specified and as directed by Engineer- in Charge.
Supply and Fixing in replacement of ceiling fan shaft and make the ceiling fan serviceable complete all as specified and directed.
S&F ISI marked electric energy meter single phase two wire LCD dispaly 5-30 Amps complete all as specified and as directed by Engineer- in Charge. Make:- HPL/BENTEC/ Secure.
S&F ISI marked electric energy meter three phase four wire LCD dispaly 10-60 Amps complete all as specified and as directed by Engineer- in Charge. Make:- HPL/BENTEC/ Secure
Supply and fixing on wall , Plug and socket in sheet steel enclosure with Single pole & earth , suitable for 20 Amp with providing MCB SP 20 Amp suitable for single phase AC supply complete all as specified and directed.
Supply and fixing in replacement of switch Modular one module one way 10 Amp complete all as specified and as directed by Engineer-in-charge.Make:- Simon cat part no.:- 381101-030 or equivalent from the make mentioned in list of make.
Supply and fixing in replacement of bell switch Modular one module 10 Amp complete all as specified and as directed by Engineer-in-charge.Make:- Simon cat part no.:- 381150-030 or equivalent from the make mentioned in list of make.
Supply and fixing in replacement of switch Modular one module two way 10 Amp complete all as specified and as directed by Engineer-in-charge.Make:- Simon cat part no.:- 381201-030 or equivalent from the make mentioned in list of make.
Supply and fixing in replacement of switch Modular one module one way 16 Amp complete all as specified and as directed by Engineer-in-charge.Make:- Simon cat part no.:- 381111-030 or equivalent from the make mentioned in list of make.
Supply and fixing in replacement of Modular type socket outlet shuttered two module combined 6/16 amps multipurpose complete all as specified and directed by Engineer-in-charge.Make:- Simon cat part no.:- 382426-030 or equivalent from the make mentioned in list of make.
Supply and fixing in replacement of Modular type socket outlet shuttered two module 5 pin 6 amps multipurpose complete all as specified and directed by Engineer-in-charge.Make:- Simon cat part no.:- 382427-030 or equivalent from the make mentioned in list of make.
Supply and fixing in replacement of Modular Electronic Fan regulator 5 stepped type 02 module complete all as specified and as directed by Engineer-in-charge. Make:- Simon cat part no.:- 382315-030 or equivalent from the make mentioned in list of make.
Supply and fixing in replacement of Modular Electronic Fan regulator 4 stepped type 01 module complete all as specified and as directed by Engineer-in-charge. Make:- Simon cat part no.:- 382314-031 or equivalent from the make mentioned in list of make.
Supply and fixing in replacement of Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings. Make : Anchor/Cona/Havells.
Supply and fixing in replacement of 3 pin 05 Amps switch socket combination, box type multipurpose 2 in 1 type (3 pin 5 Amps ) all as specified and directed. Make : Anchor/Cona/Havells.
Supply and fixing in replacement of 3 pin 15 Amps switch socket combination, box type multipurpose 2 in 1 type (3 pin 5 Amps and 15 Amps) all as specified and directed.Make : Anchor/Cona/Havells.
S&F in replacement of MCB, including making connections to DB with providing appropriate size of copper thimbles as per site reqmt for the following all as specified and directed.
S & F MCB SP of rating, 06 to 32 Amp,240 volt, 10 KA 'B' Series. Make : Indoasian/Havells/L&T
S & F MCB SP of rating, 40 Amp,240 volt, 10 KA 'B' Series .Make : Indoasian/Havells/L&T
S & F MCB SNP of rating 06 to 32 Amp, 240 Volt, 10 KA, 'C' series. Make : Indoasian/Havells/L&T
S & F MCB SPN of rating 40 Amp, 240 Volt, 10 KA, 'C' series.Make : Indoasian/Havells/L&T
S & F MCB SPN of rating 63 Amp, 240 Volt, 10 KA, 'C' series.Make : Indoasian/Havells/L&T
S & F MCB TPN of rating 63 Amp, 240 Volt, 10 KA, 'C' series.Make : Indoasian/Havells/L&T
S & F MCB TP of rating 63 Amp, 240 Volt, 10 KA, 'C' series. Make : Indoasian/Havells/L&T
S & F 40 Amps RCCB A-type (TPN-4M) 240/415 Volt, 50 Hz , 10 KA short circuit capacity and breaking capacity 100 mA.Make : Indoasian/Havells/L&T
S & F 63 Amps RCCB A-type (TPN-4M) 240/415 Volt, 50 Hz , 10 KA short circuit capacity and breaking capacity 100 mA. Make : Indoasian/Havells/L&T
S&F in replacement of metal clad plug 20A 2P+E, 230V AC , complete all as specified and as directed by Engr-in-Charge. Make:- Indoasian cat part no:- 810386
S&F in replacement of metal clad socket 20A 2P+E, 230V AC , complete all as specified and as directed by Engr-in-Charge. Make:- Indoasian cat part no:- 810390 or equivalent as approved
Supply only 12 watt ball type LED lamp, 230 volt suitable for recess mounting light fittings. Make:- Havells/Orient/ Bajaj/Philips/CG/Syska
S&F 4 ft 18/20 watt Decorative ultra slim aluminium LED lighting fixture with high lumen output, environmental friendly, energy complete all as specified and by Engr-in-charge. Make:- Havells/Orient/ Bajaj/Philips/CG
S&F in replacement of 2 feet 09 W slim LED battern (cool day light) Basic all purpose surface and wall mounted with polycarbonate housing & integrated with electronic driver.Make:- Havells/Orient/ Bajaj/Philips/CG
S&F in replacement of Decorative wall light fixture made up of Polycarbonate, suitable for 9W LED Lamp B22 base complete with all accessories as per sample , complete all as specified and as directed by Engr-in-Charge.Make: Havells /Orient/Syska
S&F in replacement 36 W LED recess mounting fitting(2' x 2') CRCA powder coated having polycarbonate diffuser powedered by independent electronic LED driver haing IP 20 protection,CCT 6000 K,230/240 VAC,lumen efficacy > 140 lm/w including connecting up with twin core twisted flexible copper conductor cable with suitable size all as specified and as directed.Make:- Havells/ Philips/ GE/Bajaj
M&L in replacement of fan capacitor/condensor 1.5 MFD, 240 volt of ceiling fan/exhaust fan/wall mounted fan.Make : Tibcon/Havells
M&L in replacement of fan capacitor/condensor 2.5 MFD, 240 volt of ceiling fan/exhaust fan/wall mounted fan.Make : Tibcon/Havells
M&L in replacement of fan capacitor/condensor 3.15 MFD, 240 volt of ceiling fan/exhaust fan/wall mounted fan. Make : Tibcon/Havells
M&L in replacement of fan capacitor/condensor 4.0 MFD, 240 volt of exhaust fan. Make : Tibcon/Havells
Supply only in replacement of Ding dong call bell , complete all as specified and as directed by Engr-in-Charge.
Notes:- (a) The amount of Rs 84905.00/- against Schedule of Credit on Page No. 117 & 118 shall be deducted from the total amount quoted against Sch 'A' while deriving the Contract Sum for Acceptance. (b) Any material required to be replaced for complaint rectification other than screws, PVC rawl plug, nuts & bolts, insulation tape, thimbles and as specified in complaint item shall be measured and paid seperately under respective supply only item. (c) The cost of attending complaints shall also include the cost of stationery required for recording complaint, complaint slips and its reports as directed by Engineer-in-charge. (d) All the complaint registered (except point wiring / sub-main wiring and connected S&F items) before 1000 Hrs of every day shall be rectified on same day upto 1700 Hrs. Any delay in complaint rectification a penalty shall be recovered @ Rs.100/ per complaint per day. (e) The items supplied by contractor as supply only shall be taken on charge by deptt. and shall be issued to contractor's trademen for incorporation against the complaints slips under item No 15 hereinbefore and proper records of same shall be maintained. (f) All T&P required by electrician for complaint rectification shall be provided by the contractor at his own cost. (g) Any desturbed surface during execution of work shall be made good as existing. Nothing extra shall be paid in this respect. The quoted rate are deemed to be included the same cost.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .