Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹90.1 LAccepted-AOC 1 NO DULIAJAN C O JAI PRAKASH YADAV PO ANANDAPARA DULIAJAN DIBRUGARH ASSAM 786692 | DIBRUGARH | ASSAM | 786692 | L1 | Accepted-AOC L1 | |
| 2 | L2₹92.4 L+₹2.3 L (2.56%)Rejected-AOC | L2 | Rejected-AOC L2 |
Tender Value
Refer Docs
EMD Value
₹1.8 L
Closing Date
15 Dec 2020, 2:00 pmClosed
Commissioner,ASHB
Office of the Commissioner, ASHB
Establishment of Cultural Research Centre-Construction of Guest House and Boundary Wall of Mayamara Ajoli Aai (Ba-Bhaga Than) Sanskritik Kendra at Majuli.
2020_UDD_19544_1
ASHB/Tech/950/2015/199/9487
Open Tender
Civil Works
Works
365 days
Majuli
Class I and II
3 documents required · 3 mandatory
₹5,000
Yes
Commissioner, ASHB
₹1.8 L
Yes
24 Feb 2022
4 Dec 2020
16 Dec 2020
4 Dec 2020
15 Dec 2020
4 Dec 2020
Amount
GROUND FLOOR AREA = 518.69 SQ.MT.
Earth work in excavation for foundation trenches of walls, retain -ing walls, footings of columns, steps, septic tanks etc. including refilling (return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all leads and lifts as directed and specified in following classification of soils including bailing out water where necessary as directed and specified.
I) Upto a depth of 2m below the existing ground level .
a) In ordinary soil
Earth/Sand filling in plinth in layers not more than 150 mm thk. including necessary carriage, watering, ramming etc. complete as directed and specified including payment of land compensati -on, Forest Roalty, Sales Tax and other duties and taxes as may be necessary
I) With silt (Predominantly non plastic ) by truck carriage including loading and unloading .
Plain Cement Concrete works.
Plain cement concrete work with coarse aggregate of sizes 13mm to 32mm in foundation bed for footings, steps, walls, brick work etc. as directed and specifoed including dewatering if necessary and curing complete (shuttering where necessary shall be be measured and paid separately)
a) In Prop. 1 cement : 3 Sand : 6 Coarse agg. by volume
Providing and laying plain/reinforced cement concrete work with coarse sand & 20 mm down graded stone aggregate including dewatering if necessary and curing complete supply of materials but excluding cost of form work and reinfircement for reinforced cement concrete work ( form work and reinforcement will be measured and paid separately )
(I) Using mixture machine
(A ) In sub-structure upto plinth level.
I) Foundations, footings, columns with base tie and plinth beam, grade beam ,pile cap ,base slab, retaining wall, walls of septic tank, inspection pit and the like and other works not less than 100mm thick upto plinth level.
N) Without using admixture, plasticiser
b) M 20 grade concrete or Prop 1:1.5:3
B ) In super structure from plinth level up to 1st floor level..
ii ) Columns, pillars, posts, struts, suspanded floor, roof, landing, shelf and support, balcony, lintel,sill band , beam, girder, cantilever,staircase (except spiral staircase and landing) including preparing of top surface and finishing of nosing.
N) Without using admixture, plasticiser
b) M 20 grade concrete or Prop 1:1.5:3
iii) Vertical and horizontal fins (thickness not more than 100mm) individually or forming box louvre and projected band.
N) Without using admixture, plasticiser
b) M 15 grade concrete or Prop 1:2:4 (Qty LS)
Providing and laying 25 mm thick damp proof course with cement concrete in prop. 1:1.5:4 with graded stone aggregate of 10mm down nominal size including providing approved damp proff mixture in prop. as recomended by the manufacturer including curing etc. complete as directed.
BRICK WORK
Providing brick soling in foundation and under floor with stone/ best quality picked jhama bricks, sand packed and laid to level and in panels after preparing the surface as directed including all labour and materials and if necessary dewatering complete .
a) Brick on flat soling
Brick work in cement mortar with 1st class brick including racking out joints and dewatering if necessary and curing complete as directed in sub structure upto plinth level.
(I) In Sub-structure upto plinth level including dewatering if necessary
b) In proportion 1:4
1st class brick nogged wall in cement mortar including racking out joints and curing complete as directed in super structure above plinth up to 1st floor level (protruding M.S rod/Tor steel of column to be embeded in cement mortar and will be measured and paid separately)
(A) 112 mm thick brick wall
a) In cement morter in proportion 1:4( 1 cement :4 sand)
SHUTTERING AND FORM WORK
Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc. hight of propping and centering below supporting floor to ceiling not exceeding 4 m and removal of the same for insitu reinforced cement concrete and plain concrete work in
Foundation, footing, base of columns, pile cap, raft and mass concrtete works etc.
a) Using 38 mm thick plank
Sides of tie beams, plinth beams, grade beams etc.at or below ground level
(a)) Using 38 mm thick plank
Columns, pillars ,posts & strut
(b) Circular or curved in plan (Using 38mm thick plank)
I) Using 38 mm thick plank
Sides and soffits of beams, beam haunching, cantilever girders, bressumers, lintels and horizontal ties
a) For depth not exceeding 1.0M
I) Using 38 mm thick plank
iii) Flat surface such as soffits of suspended floors, roofs, landings, cantilever slabs, chajjas balconies and the like.
a) Floors etc. upto 200 mm in thickness
I) Using 38 mm thick plank
Vertical ties, fins, sun breaker, louvers, band, dropwalls etc.
I) Using 38 mm thick plank
Providing form work of 12 mm thick plywood board and removal of the same in edges of slabs and breaks in floors and walls etc. of in -situ reinforced concrete works upto 1st floor level.
a) Thickness not exceeding 200mm
PLASETRING AND POINTING
15 mm thick Cement plaster in single coat on single or half brick wall for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80mm girth and finished even and smooth including curing complete as directed.
A) On rough side
b) In cement mortar 1:4
B) On fair side
b) In cement mortar 1:4
10 mm thick Cement plaster in single coat on fair side of brick/concrete walls for interior plastering up to 1st floor level including arises or rounded angles not exceeding 80mm girth and finished even and smooth including curing complete as directed.
b) In cement mortar 1:4
Extra for plastering on ceiling and soffits of stair up to 1st floor level including curing complete as directed.
I) Ground floor
15 mm thick plain cement mortar bands in cement morter 1:4 in width including curing complete as directed.
A) Up to 300 mm width
a) Flush Band
b) Sunk Band
FLOORING :
65 mm thick cement concrete floor consisting of 50 mm under layer of cement concrete in prop. 1:3:6 (1cement : 3 coarse sand : 6 coarse aggregate of 25mm and down) and 15 mm thick wearing layer in cement concrete in prop. 1:1:2 (1cement :1 coarse sand : 2 coarse aggregate of size 10mm down) laid in panels and finished with a floating coat of neat cement finish (using cement slurry for bond @ 2.75 kg. per square metre of floor area) including curing etc. complete as directed.
Cement plaster skirting with cement mortar ( 1 cement : 3 coarse sand ) finished with a floating coat of neat cement including rounding of juctions with floor.
b) 20 mm thick .
Providing Ceramic Tiles of approved quality, size, shape and thickness not less than 8 mm on floors, skirtings, treads and risers of steps over cement mortar bed 15 mm thick in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with fix-A Tile Choksey/ Sika/ Pedelite/ Rouf/ White cement slurry mixed with approved pigment to match the shade of granite slab, complete at all levels as specified and directed (coloured pigment should be in conformity with colour of slab and as approved and directed by the Department).
Executive range Somany/ Orient/Nitco/Asian Make
Of size 600mmx600mm and above
Providing polished granite slab of approved quality, size, shape and thickness not less than 18 mm on floors, skirtings, treads and risers of steps over cement mortar bed 15 mm thick in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile Choksey/Sika/Pedelite/Rouf) /white cement slurry mixed with approved pigment to match the shade of granite slab, complete at all levels as specified and directed. (Cement plastering to be measured and paid separately). (Coloured pigment should be in conformity with colour of slab and as approved and directed by the Department).
Providing 18 mm thick Granite slab on vertical face of pedestal laid over 10 mm (1 cement :3 coarse sand ) jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete as directed with approved quality of shade.
Supplying, fitting, fixing and painting where necessary (one coat primer and two coats of paint) M/F Suspended Ceiling which includes G.I. perimeter channels of size 0.55mm thick (having one flange of 20mm and another flange of 30mm and a web of 27mm) along with perimeter of ceiling, screw fixed to brick wall/ partition with the help of nylon sleeves and screws, at 610mm c/c. Then suspending G.I. intermediate channels of size 45mm (0.9mm thick with two equal flanges of 15mm each) from the soffit at 1220mm c/c with ceiling angle of width 25mmx10mmx0.55mm thick fixed to soffit with G.I.cleat and steel expansion fasteners.
Ceiling section of 0.55mm thickness having knurled web of 51.5mm and two equal flanges of 26mm each with lips of 10.5mm are then fixed to the intermediate channel with the help of connecting clip and in direction perpendicular to the intermediate channel at 457mm c/c, 9.5mm/ 12.5mm tapered edge Gypboard (conforming to IS:2095-1982) is then screw fixed to ceiling section with 25mm long drywall screws at 230mm c/c. Screw fixing is done mechanically either with screw driver or drilling machine with suitable attachment. Finally, the boards are to be jointed and finished so as to have a flush look which includes filling and finishing the tapered and square edges of the boards with jointing compound, joint paper tape and two coats of drywall topcoat suitable for Gypboard complete at all levels as specified and directed. (For light fittings, providing opening for doors, window, ventilators etc, cut out made with frame of perimeter channel supported suitably to be measured and paid separately where necessary).
9.5mm thick
Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete. (No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate) (Upto 1st floor level)
a) From Primary Producer: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel/RINL
(ii)Super Ductile (SD) TMT reinforcement bars
Providing, fitting and fixing M.S. Grill of required pattern for winddows / clearstory windows / openings with M.S. flats at required spacing and farmed alround square or round M.S. bars with round headed bolts and nuts or screws.
a) Ornamental Grill
c) Fixed to brickwork/ P.C.C/R.C.C.
Providing, fitting, hoisting and fixing of roof trusses fabricated out of combination of any two or all of the following sections (i) Square section (ii) Rectangular Hollow section of specification RSH/SHS and (iii) M.S. circular hlollow section of Grade 210 including purlins, bottom runners and providing M.S. cleat, M.S. angle base plank, bolts and nuts with red oxide primer including fitting bottom runner and cleat etc. for fixing ceiling joist as per design complete as directed as per specifications.
a) Using TATA make RHS/SHS of Grade 310 conforming to relevant I.S. code 4923 : 1997
Providing Pre Painted Galvalume Sheet Roofing (PPGL) at all levels including fitting and fixing self drilling, self tapping screws complete (Roof trusses, purlins etc. to be measured and paid separately.)
TATA Blue scope/ Dyna roof / Durakolor /Wonder Roof or equivalent as directed by the Departement
(iv) 0.60 mm thick
Providing Pre Painted Galvalume Sheet (PPGL) accessories ( Ridges / Valley / Gutter / Flashing) at all levels including fitting and fixing self drilling, self tapping screws complete. TATA Blue scope/ Dyna roof / Durakolor /Wonder Roof or equivalent as directed by the Departement
(iv) 0.60 mm thick
Painting
Applying primary coat over new steel and other metal surface over 100m in width or girth after preparing the surface by throughly cleaning oil,grease, dirt and other foreign matter and scoured with wire brushes, fine steels, wood scrapers and sand paper.
a) With ready mixed red lead red oxide primer
Painting two coats ( excluding priming coat ) on new steel and other metal surfaces with enamel paint of approved brand and manufacture( Asian paint/Berger paint/ICI paint/ J &Npaint/Nerolac to give an even shade including cleaning the surface of all dirt, dust and other foreign matter .
(I) Surfaces over 100 mm in width or girth
b) High gloss ( Asian paint/ Berger paint/ ICI paint / J& N paint / Nerolac)
Providing two coats of acrylic water based wall putty/ wall filter of Asian Paints/ Berger/Dulux (ICI)/ Nerolac over concrete/cement plaster/ brick walls ( internal )and after removing all the loosely adhering material from the wall/ceiling surface with the help of emerey stone ,putty blade or wire brush, moistening the wall with the help of sufficient quantity of clear water as specified and directed by the department.
c) Applying one coat of distemper primer of approved brand and manufacture on wall surfaces after thoroughly brushing the surface free from mortar drops and other foreign matter and including preparing the surface even and sand papered smooth.
(a).Plastic Emulsion Paint of approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac)
a) Providing one coat of cement primer( on ext. wall) of approved brand and manufacture on new surfaces after thoroughly brooming the surface preparing the surface even and sand papered smooth.
Finishing old /new wall with water proofing weather coat smooth anti-fungal premium textured exterior finish , finish of Sandex Matt brand of Snowcem India Ltd. Of required shade after cleaning and clearing the surface etc. including scaffolding complete as directed at all levels ( two coats)
MISCELLANEOUS
Pre construction antitermite treatment at the bottom of foundation of foundation pits and walls on either side up to a height of 300m.m. from bottom of the excavation made for column ,plinth beam, wall trenches etc. by applying the emulsion @ 5 litres per sq.mt. Of the surface area before starting construction work( supplying of necesary tools and accessories by the contractor) as per the direction of the Department complete.
a)with aquous emulsion having concentration 1:19 with chloropirophose solution (tricel or equivalent) and water ,I,e, 1% solution.
Providing plinth protection with bricks flat laid in cement mortar 1: 4 and finished with 15mm thick cement plaster in prop. 1:2 with a floating coat of neat cement finish.
Providing drain with brick work in cement mortar in proportion 1:5 with half brick thick side walls and 100mm thick C.C (1:3:6) base over one brick flat soling including 15mm thick cement plastering in prop. 1:3 finished with a floating coat of cement slurry as directed with necessary shttering for sides and earth work in excavation of foundation trenches and refilling the sides after completion of work etc. as specified.
ii). 300mm wide and average 250mm deep with bed slope 1 in 150 with initial depth of 100mm.
HARDWARE FITTINGS
Supplying, fitting and fixing alluminum fittings of approved make reasonably smooth, free from sharp edges, flows and other defacts with counter sunk holes for screws including necessary aluminium screws etc. complete ( annodised to a bright natural mat or stain finish).
a) Sliding door bolts
b) Tower bolt
ii) 250 X 12 mm
c) Door handle
e) Butt hinge v ) 100 mm x75mmx 4mm
INTERNAL ELECTRIFICATION WORKS
Wiring for light/fan/call bell point with 2x1.5 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed conduit wiring system with 20mm dia 2mm thick / heavy rigid PVC IS: 9537 Part - III conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) including 6 Amp flush type switch/ bell push (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.) GI/ MS switch board (ISI marked) with phenolic laminated sheet cover ,ceiling rose (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.) etc. complete
b)Medium point upto 6.00mtr length
c)Long point upto 10.00mtr length
Wiring to 5 a pin 6 Amps plug point with 1.5 sq. mm P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed 2 mm thick/ heavy rigid ISI marked IS: 9537 PART - III rigid PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) wiring system including 5 pin 6 Amps flush type plug socket and 6 Amps F/T switch (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.), GI/ MS switch board (I.S.I. mark with phenolic laminated sheet cover including earth continuity with 1.5 sq. mm. cable to third pin of the plug socket etc. as required complete, when placed elsewhere.
b)Medium point upto 6.00mtr length
Wiring for 5/6 pin 16 Amps power plug point with 4 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed conduit wiring system including and fixing 5/6 pin 16 Amps flush type socket outlets and 16 Amps flush type switch (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt./ Havells make), GI/ MS switch board (I.S.I. mark with phenolic laminated sheet cover earth continuity with 2.5 sq. mm cable to the 3rd pin of the socket as required complete with 20 mm. dia. 2mm thick/ heavy rigid ISI marked IS: 9537 PART - III rigid PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.)
Extra long point up to 25.00 metre. Length.
Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) including earth continuity in surface/ recessed 20 mm. dia. 2mm thick/ heavy ISI marked IS: 9537 PART - III rigid PVC conduit wiring system.
With 2 x 2.5 sq. mm. + earth continuity with 1x1.5 sq. mm. in 20 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.
With 2 x 4 sq. mm. + earth continuity with 1x2.5 sq. mm. cable in 20 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.
With 2 x 16 sq. mm. + earth continuity with 1x10 sq. mm. cable in 32 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.
Supplying with fitting and fixing sheet steel, phosphatised, powder painted dust & vermin proof Double door IP-43 surface mounting SPN MCB DB incorporated with bas-bar, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt.
12 way SPN double door
Supplying with fitting and fixing sheet steel, phosphatised, powder painted dust & vermin proof Double door IP-43 double door surface mounting TPN MCB DB incorporated with bas-bar, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt.
6 way TPN (4+18) double door
Supplying with fitting and fixing single Pole 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt.
B Series (Schneider MG, legrand, Hager make)
Supplying with fitting and fixing SPN 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt.
B Series (Schneider MG, legrand, Hager make)
Supplying with fitting and fixing 4P 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt.
C Series (ABB, Schneider MG, legrand, Hager make)
MCCB with Thermal & Magnetic Release
Supplying with fitting and fixing panel mounting open execution 25 KA 415V 50Hz 3P MCCB (Ics=Icu, adjustable Ir setting 0.7) without enclosure of the following capacity complete with making necessary connection as approved by the Deptt. as specified and directed by the deptt.
25 KA 415V 50 Hz 3P MCCB (Schneider, legrand, Siemens make)
Supplying including fitting and fixing of high speed AC Ceiling fan complete with all accessories like , down rod, canopy etc.of following sweeps with making necessary connection etc.as reqd complete and directed by the deptt.(Without regulator)
a) 1400mm sweep
Installation ,testing and commissioning of ceiling fan including the regulator, down rod of standard size(up to 300mm length) and connection etc complete as specified and directed by the department.
Supplying fitting and fixing of single wall brackets model 37712 (or equivalent as approved by the Deptt.) on the wall in GI/ MS switch board (ISI marked) half conceal on wall with phenolic laminated sheet cover with all accessories including connection as required complete. Without lamp.
Supplying with fitting fixing of CFL/Fluorescent luminaries complete with all accessories such as ballast, starter etc. directly on wall / ceiling including connection as approved by the Deptt.)with 1.5 sq mm P.V.C. insulated S.C. copper conductor as required and as directed by the department.
Supply and laying of following size PVC/XLPE insulated and PVC sheathed 1.1 KV G Solid Aluminium conductor up to 10 sq mm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armour (Aluminium for single core up to 70 sq mm balance Aluminium strip, Galvanised for cables up to 2x10 sq mm.3x10 sq mm,4x6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 sheathed, 650/1100V grade as per IS 7908(Part 1) 1988 armoured U.G. cable U.G. cable laid in ground/partially in air (as required for termination over ground including excavation of cable trench up to depth of 75cm, refilling, protective brick covering, Sand cushioning etc complete handling of surplus spoil, debris et to proper place as specified and directed by the deptt. (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make) .
185.00 Sq.mm 4 Core U.G. cable in 80 mm dia medium duty hot dip galvanised pipe (AKG or equivalent as approved by the Deptt.)
Supply, installation & testing of G.I. earth station with perforated 40 mm dia and 4.50 Metre long heady duty G.I. pipe with necessary 40 mm dia. G.I. Fittings such as Socket, Tee, elbow, nipple and 50 mmx40 mm G.I. reducing socket for funnel including locking arrangement 300 mmx300 mmx6 mm hinged cover C.I. earth plate complete with digging of earth pit, construction of brick chamber and plastering of both inner & outer surface of wall as specified and directed by the deptt .
Extra for using salt (5 K and Charcoal (64 K in pipe Earth Station pit to provide low impedance ground in location of high soil resistivity as and when required and specified by the Deptt.
Supplying & laying of 8 SWG Copper. earth from Earth Electrode (below G.L.) to electrical switch gears or electrical machineries including making necessary connection as approved, specified and directed by the deptt.
Supplying & laying of 6 SWG G.I. earth from Earth Electrode (below G.L.) to electrical switch gears or electrical machineries including making necessary connection as approved, specified and directed by the deptt.
Supplying & laying of 25x4 mm size Copper strips drawn on surface from earth electrode to Electrical switch gears, machineries etc complete with supply of Brass nuts & bolts, screws etc including riveting, soldering & making necessary connection as approved, specified and directed by the deptt.
Supply, fitting & fixing of Lighting Finial Arrestor made of 25 mm dia 300 mm long solid Copper tube having 85 mm dia. single prong at top and 3 mm thick base plate at bottom complete with fitting & fixing with Brass nuts & bolts on roof, RCC slab, top of column etc. as specified and directed by the deptt.
Supply, fitting & fixing 20 mmx5 mm G.I. strips drawn on vertically or horizontally on building wall/parapet wall in surface system complete with supply of G.I. Nuts & Bolts, Screws etc including riveting, soldering and making connection as approved by the Deptt.)with earth electrode G.I. strips and Lightning Arrestor etc. as specified and directed by the deptt.
Supplying and installation and commissioning of vermin and dust proof totally enclosed double door cubical type compartmental floor mounting panel board of size 1.20 m ×1.00 m ×0.50 m made of 16 SWG1.66mm) thick CR sheet and 35 mm × 35 mm × 6 mm size angle and 35 mm ×6 mm flat iron having 4 nos legs at the bottom and G.I. Sheet reefing on the top complete painting with 2 coats of red oxide metal primer and 2 coats of enameled paint. The panel board is to be erected in 1:3:6 RCC pole foundation including excavation of trench and brick soling etc. complete neatly internal wiring done as specified and directed by the department comprising of the following electrical items.
1. 40 Amp 4 pole 415 Volt 50 Hz MCCB as incomer - 1 no
2. 32 Amp 2 pole open execution with HBC fuse SDFU unit as outgoing - 3 nos.
3. 25 mm × 5 mm size 4 strip copper Bus-Bar- 1 set
4. 40 Amp 4 pole ON-OFF poser contactor - 1 No.
5. Surface mounting timer switch - 1 No.
6. 63 Amp bakelite HBC fuse kit-kat - 3 Nos
7. 0-40 Amp electro-mechanical counter display 3 Phase 4 wire electronic hybrid energy meter
Supplying including installation, connection as approved by the Deptt., testing and commissioning of JET PUMP SET (HORIZONTAL) complete as directed and specified by the deptt.
1 HP single Phase jet pump set (Horizontal(Crompton Greaves/ Aquatic/ CRI/ V-Guard make) 2900 rpm with DOL Starter ( Crompton Greaves/ Control & Switch Gear/ BCH/ L& T / Siemens make) .
SANITARY WORKS
Providing fitting & fixing stainless steel kitchen sink of Parryware make with CI/MS brackets, C.P. brass chain with rubber plug, PVC waste pipe etc. complete including painting the fittings ,cutting &making good the walls wherever required. (Sink cock, stop cocks, waste coupling are to be paid separately
(vi) Single Bowl (160 x 180) Flat Edge - Glossy (Cat.No.C8538)
Providing, fitting and fixing recessed soap tray / soap dish complete as directed and specified.
(A) Parryware Make
(ii) Wall Soap tray (Cat. No.C9951)
Providing, fitting and fixing CP towel ring complete as directed and specified.
(a) Sona make
(i) Towel ring round( Cat No. TR 06051)
Supplying, fitting and fixing PVC pipes of 6 Kg/cm2 (Supreme/Prince) or other ISI approved including joining ,fitting and fixing wiyh clamps etc.as necessary complete at all levels including below G.L as directed and specified.
a) In exposed surfaces or in trenches.
(ii) 110mm dia
Supplying, fitting and fixing 87.5 degree PVC bend of (Supreme/Prince) or other ISI approved including joining ,fitting and fixing etc.as necessary complete at all levels including below G.L as directed and specified.
a) In exposed surfaces or in trenches
ii) 110 mm dia.
Supplying fiting and fixing 87.5 degree PVC bend with door of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified.
a) In exposed surfaces or in trenches
ii) 110 mm dia.
Providing fitting and fixing 100 mm dia PVC Cowel with ISI make complete as directed and specified.
Providing fiting & fixing C.I. Grating to the floors complete as directed and specified.
b) 110 mm dia
WATER SUPPLY WORKS
Supplying fitting and fixing approved uPVC Pipes of different sizes, with all necessary 'R' brand or similar approved P.V.C. Fittings such as bend, tee, elbow, reducer, nipple, plug, long screw fitting, clamps etc. complete at all levels including below G.L. as directed and specified.
(A) Exposed or in trenches
SUPREME/ PRINCE/ SFMC BRAND or other equvalent approved brand (High presure pipe Sch-40)
Exposed or in trenches
b) 40 mm dia
(B) Concealed by chieselling or breaking brick wall/ C.C. wall/ R.C.C. wall and making good to the damaged structure.
SUPREME/ PRINCE / SFMC / FUSION BAND or other equvalent approved brand (High presure pipe Sch-40)
d) 25 mm dia
f)15 mm dia
Supplying fitting and fixing C.P. bib cock 15mm dia of approved brand directed and specified. (G.I. & C.P pipes will be measured separately)
II) Jaquar make
a) Continental/ Clarion
I) Standard
Supplying fitting and fixing Chrome plated (C.P.) stop -cock of approved brand and size as mentioned below as directed and specified ( G.I. & C.P. pipes will be measured and paid separately)
I) Jaquar
(a) Continental /Clarion
(ii) 15 mm dia Male /Female ( Long thred)
Supplying and fitting fixing C.P. pillar cock of 15 mm dia of approved brand as specified and directed.
ii) Jaquar make
(b)Long neck with areator
Supplying and fitting gun metal country pit valve ( full way valve) I.S.I Make as specified and directed
b) 40 mm dia
Labour for sinking tube well with 40 mm ( internal) dia G.I. Pipes up to strata, having potable water including fitting and fixing strainer , hand pump and other accessories as directed complete as in any soil
Supplying, fitting and fixing suction pipes ( plain/ bevel ended) , conforming to relevant IS codes of practice including supplying and fitting of accessories, lowering of assembly pipes concentrically in the casting pipes complete as directed
( I) G.I. Pipe
(a) TATA/SAIL (medium)( sockets should be welded to the pipes)
iii) 40 mm diameter
Supplying fitting and fixing brass Tez filter 2.00 meter long.
Supplying fitting and fixing check valve ( non return valve ) including threads to pipes
c) 40 mm dia
Supplying, fitting and fixing Maya Hand pump No 6 for 40 mm dia tube well with all accessories complete as directed
Flushing , clearing, washing and watering of the tube well
Supplying fitting and placing plastic cylindrical vertical closed top ( PCVC) tank of Sintex/ Polycon/ Patton make over the stagging with manhole cover with locking arrangement and cleaning arrangement including providing pads of sizes as required for inlet and outlet piped complete as directed with labour charge
( I) 1000 litre capacity
(a) Sintex make
Add 20% for works in Majuli Sub Division of Total Civil Works(Civil+Electrical+Water Supply)
SRI HEMANTA DAS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .