Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.9 LAccepted-AOC BEHIND HYUNDAI SHOWROOM GROUND FLOOR PLOT NO 44 BLOCK C DSIDC MANGOLPURI INDUSTRIAL AREA PHASE 1 NEW DELHI 110 083 | NEW DELHI | NORTH WEST DELHI | DELHI | 110083 | L1 | Accepted-AOC Quoted Lowest | |
| 2 | L2₹16.2 L+₹1.6 L (10.8%)Rejected-Finance 24 GROUND FLOOR PUJIT PLAZA SECTOR 11 CBD BELAPUR NAVI MUMBAI 400614 | THANE | MAHARASHTRA | 400614 | L2 | Rejected-Finance Not Quoted Lowest | |
| 3 | L3₹17.8 L+₹3.2 L (22.1%)Rejected-Finance P 27 1 RASHTRAGURU AVENUE DUM DUM KOLKATA 700028 | 24 PARAGANAS NORTH | WEST BENGAL | 700028 | L3 | Rejected-Finance Not Quoted Lowest | |
| 4 | Rejected-Technical | - | Rejected-Technical Not Eligible as per NIT | |
| 5 | Rejected-Technical 79 MAHENDRA BANARJEE ROAD BEHALA KOLKATA 700060 | KOLKATA | WEST BENGAL | 700060 | - | Rejected-Technical Not Eligible due to not Submission of Short Fall Documents |
Tender Value
₹19.1 L
EMD Value
₹38,203
Closing Date
27 Dec 2023, 11:00 amClosed
Samar Kumar Biswas AGME E
AAi RHQ ER NSCBI Airport Kolkata 700052
SITC of Signages at Dumka Airport
2023_AAI_176613_1
AAI/ER/RCS/DUMKA/2023-24
Open Tender
Electrical Works
Works
60 days
Dumka Airport
Please refer Tender documents.
8 documents required · 8 mandatory
₹1,180
Yes
₹38,203
10 May 2024
6 Dec 2023
28 Dec 2023
6 Dec 2023
27 Dec 2023
6 Dec 2023
6 Dec 2023 - 11 Dec 2023
Amount
SITC of Signage (Type 1.2 Periphery Airport Name Sign) way finding Signage Design, AAI Signage Guideline. (Size:- 4200*1125 mm ) as per approved by EIC.
SITC of Signage (Type 1.3a1 Vehicular Directional sign- Pole Mounted) Refer design drawing way finding Signage Design, AAI Signage Guideline.(Size:- 1300*2100 mm ) as per approved by EIC.
SITC of Signage (Type 1.4a Traffic Statutory Sign) way finding Signage Design, AAI Signage Guideline. (Size:- 600*600 mm ) as per approved by EIC.
SITC of Signage (Type 2.1a Ceiling Hung Directional Sign) way finding Signage Design, AAI Signage Guideline. (Size:- 2100*255 mm ) as per approved by EIC.
SITC of Sign (Type 2.2a Wall Mounted Facility Announcer) way finding Signage Design, AAI Signage Guideline. (Size:- 900*450 mm ) as per approved by EIC.
SITC of Sign (Type 2.4a Washroom/Drinking water/Baby Care) way finding Signage Design, AAI Signage Guideline.
2.4a1(Double Sided Wall Projected), (Size:- 450*450 mm ) as per approved by EIC.
2.4a2(Single Sided Wall Mounted), (Size:- 450*450 mm ) as per approved by EIC.
SITC of Signage (Type 2.6a Emergency Direction Signs illuminated) way finding Signage Design, AAI Signage Guideline.
"EXIT" With Arrow sign (2.6a-1), (Size:- 675*255 mm ) as per approved by EIC.
"Emergency Exit" With Arrow Sign (2.6a-2), (Size:- 900*225 mm ) as per approved by EIC.
SITC of Fire Extinguisher, Size- 200mm x 200mm
Mcp, Size- 200mm x 200mm
Switch Room, Size- 150mm x 300mm
CCTV Room, Size- 150mm x 300mm
Supply of following sizes of XLPE insulated PVC sheathed, Aluminium conductor armoured power cable of 1.1KV grade confirming to IS 7098, Part-I 1988 with up to date amendments.
3.5c x 25 Sq. mm
DSR item ( Rate will be considered % above / below of or equal to 100% of DSR 2018 E&M rate). NOTE:-The execution of Delhi Schedule of Rates (E&M) 2018 Items as when required basis. Example for quoting the rate:- (i)Agency Quoting Rs.1,80,000.00 in the Rate stands for 10% below the Estimate amounting of Rs.2,00,000.00 net amount will be 1,80,000.00 and payment will be made 10% below on DSR 2018 rate against items. (ii)Agency Quoting Rs. 2,20,000.00 in the Rate stands for 10% above the Estimate amounting of Rs.2,00,000 net amount will be 2,20,000.00 and payment will be made 10% above on DSR 2018 rate against items. (For Payment calculation please refer relevant Technical specification of Tender Document)
SITC of below mentioned length Automatic electrmechanical type boom barrier suitable to work on 230±10% volt, 50 Hz AC supply having following features. 1. Boom should be made of white painted aluminum alloy finished with powder coating with bright red reflective tape strips in order to be visible even at night having section of 100 mm. x 40 mm and supported on rest post. 2. Height of boom from ground should be 700-1000 mm 3. Opening & closing time should be 3 to 8 second 4. The control unit should be housed in weather proof housing made with 2mm cold roll steel sheet with IP 54/IP 55 Protection. 5. Control Unit should be Microcontroller/PLC based. 6. Its Operation should Stand along with push button switch & wireless remote control and can also shall be integrated with access control, RFID readers, tyre killers, road blockers, bollards etc. 7. Operating temperature must be in the range of -20 to +55 degree C 8. Optical beam sensor/photo cell should be provided to prevent barrier from closing on the vehicles. 9. Smooth operation of boom barrier while open and close without bounce/ jerks at end positions. It shall permit short opening & closing without barrier boom bouncing in the end positions. The lever docks the barrier boom at both end positions. 10. On power failure, barrier can be raised or lowered by releasing the boom dock with key type mechanism. 11. It should have a durable motor for long lasting purpose and generate approx 200 Nm torque. 12. Blinker should be integrated at the frame. (Civil works like flooring, Finishing etc. as per OEM standards included)
5.5 Mtr Length
SITC of Electronic Weighing Scale with bearing capacity 150 kg of Size : 500mmX500mm.
Vinayak Infra Signs and Projects Pvt Ltd
Youngmen Traders
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .