Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹30.8 LAccepted-AOC WARD NO 20 BIRLA HOUSE JEDERUA KALA DISTT GWALIOR M P 474006 | GWALIOR | GWALIOR | MADHYA PRADESH | 474006 | 1 | Accepted-AOC LOWEST | |
| 2 | 2₹31.8 L+₹44,600 (1.42%)Rejected-Finance | 2 | Rejected-Finance other than lowest | |
| 3 | 3₹41.8 L+₹10.5 L (33.4%)Rejected-Finance | 3 | Rejected-Finance other than lowest | |
| 4 | 4₹45.7 L+₹14.4 L (46.0%)Rejected-Finance | 4 | Rejected-Finance other than lowest | |
| 5 | 5₹45.8 L+₹14.5 L (46.3%)Rejected-Finance | 5 | Rejected-Finance other than lowest |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
25 May 2024, 6:00 pmClosed
GE (AF) TECH AREA GWALIOR
GE (AF) TECH AREA GWALIOR
REPAIR/MAINT TO WALL PANELLING, FALSE CEILING, PLINTH PROTECTION PCATT, HARD STANDING, FLOORING, PLASTERING, ROOF SHEETS AND OTHER CERTAIN E/M WORKS IN TECH AREA AT AF STN GWALIOR
2024_MES_650779_1
8900/1526/GWL/E8
Open Tender
Civil Works
Item Rate
330 days
GWALIOR
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) TECH AREA GWALIOR
₹90,000
Yes
13 Jul 2024
23 Apr 2024
3 Jun 2024
23 Apr 2024
25 May 2024
18 May 2024
Amount
Dismantling of wall and ceiling boards (fibre ,pulp, insulation etc ) or insulation boards /slabs/ blankets any thickness including wall paneling cover fillets or aluminium / GI grid frame work complete all as specified and directed
S&F 5mm thick solid PVC wall Paneling/lining any colour wood grains printed PVC pre laminated sheet, one side including beadings at top, bottom, corners of door and window jambs of matching colour inclusive of solvent cement and fixing at site over PVC frame complete all as specified and directed. Note: Colour, pattern and design as approved by GE.
S&F PVC wall lining/Paneling consisting of 10 mm thick hollow section interlocking type fixed to wall any colour wood grains/ printed decorative PVC sheet, pre laminated inclusive of solvent cement and fixing with hidden screws and all necessary beadings at top, bottom, corner, Jambs, complete all as specified and directed by Engr-in-Charge. Note: Colour, pattern and design as approved by GE.
M & L for 5mm thick PVC sheet fillet of width 35mm for wall panelling inclusive of fixing on to wall to make PVC Frame complete all as specified and directed.
S&F "ACOUSTIC PERFORATED PRELAM PVC WALL PANELLING consisting of PVC perforated panels having wall thickness of 4.5/5mm PVC sheet(of density 600/Kg/Cum and the desired thickness of glasswool/rockwool pasted with perforated sheet with suitable adhesive. The strips should have in there centre a grove of 6mm width and 1mm depth for sinking the head of the screw used to fix the strips to the wall vertically at an equal interval of 10" between two PVC strips. The PVC strips shall be fixed to the wall usin 65mm long MS screws through the groove in the strips by using PVC rawl plugs. The distance of two screws shall not be les than 200mm . A grove of 2mm be left at the joint of two panels for asthetic looks. The wall screws shall be placed at a distance of 15mm and shall be 25mm from the edge of the of the insulated pannel on all four side of the panel. The PVC strips of 5mm thick PVC sheet of width 75mm feathered at the edges shall be stuck using solvent cement adhesive at the places where two panels are joined, so as to cover the screw of both the pannels, using solvent cement heat bent strip of 5mm hick PVC sheet of width 75mmx75mm feathered at edges shall be stuck at wall joints/pillars etc complete all as specified and directed by Engineer-in-Charge.
S&F 30mm thick Acoustic peforated prelam PVC false ceiling panel made of 4.5/5mm thick PVC perforated sheet of size 600mmx600mm on 25mm glasswool/rockwool pasted with perforated sheet with suitable adhesive. The panel is inserted in a frame made of GI 'T' & 'L" section of size (25mx25mm) in square type grid of 600mmx600mm the false ceiling 4mm dia GI suspender of suitable size and dash fastners to be provided @ 1.20 mtr distance complete all as directed.
M&L 16mm thick acoustic mineral fibre micro perforated finish (Reveal type) approved pattern with exposed GI framework grid 600mm x 600mm grid with approved pattern fixed over and including pre powder coated GI frame with suspension system (Grid) comprising of T section 25mmx 32.5mm x1.60mm size as main runners and wall angle to placed along the wall at desired level of the False ceiling 4mm dia GI suspender of suitable size and dash fastners to be provided @ 1.20 mtr distance complete all as directed. Make : Gyproc Saint Gobain, Armstrong (RH 99 Dune) or equivalent etc
S&F 4mm thick HPSC pre-prime non asbestos fibre cement designer building board (E-classic ) decorative finish including E-grid suspended false ceiling grid system 600x600mm with main runner 33x24x0.6mm, cross tee 25x24x0.6mm and wall angle 19x22x0.4mm ceiling suspended with 4mm dia GI wire hanger fixed with steel dash fasteners to RCC Roof or from purlin with butterfly clips hold down clips etc from soffit at approx 1.20mtr centre to centre complete all as specified and directed.
S&F in repairs 12mm thick Armstrong SCALA RH-70 Ceiling board with approved pattern (Make- Armstrong) 600x600mm size fixed to existing grid False ceiling including necessary tightening and levelling all as specified and directed complete all as directed. Note:(item 1 to 9)- Quoted rates inclusive of removing all electric fittings and fixtures and refixing the same at its positions after finishing false ceiling work and replace if any damaged while doing the work complete all as specified and directed by Engineer-in-Charge.
Demolition of cement concrete ( unreinforced) including floor tile ground floors and pavings n. exc 15 cm thick below or above G.L complete all as specified and directed .
M&L for 25 mm thick PCC (1:2:4) type B-0 (12.5 mm graded stone agg) as in sub base of flooring/tiling complete all as specified and directed.
M&L for 75 mm thick plain cement concrete (1:3:6) type C2, using 20 mm graded stone aggregate as in Plinth protection and finishing the surface even & smooth with using extra cement complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises and all as directed.
M&L for glazed ceramic Coloured tiles in vertical surface 450X 300X 7-8 mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match including 10mm thick rendering on fair faces of brick work or concrete surface in cement mortar 1:4 complete all as specified and directed.
M&L for 10 mm thick double charged vitrified coloured ceramic tiles (square/ rectangular) area of each tile not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with tiles over 15mm thick screed bed in CM 1:6 complete all as specified and directed.
All as per above here-in-before but as in skirting/dado but over 10mm thick rendering in CM 1:4 as backing coat complete all as specified and directed.
M&L for 10 mm thick double charged vitrified coloured ceramic tiles (square/ rectangular) area of each tile exc. 0.42 Sqm but not exceeding 1.00 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with tiles over 15mm thick screed bed in CM 1:6 complete all as specified and directed.
All as per above here-in-before but as in skirting/dado but over 10mm thick rendering in CM 1:4 as backing coat complete all as specified and directed.
Dismantling Stone slabs and tiles, pavers of any description or thickness aid dry or pointed in floors, aprons etc complete all as specified and directed.
M&L for 75 mm thick PCC 1:4:8 Type D2 (using 40mm graded Stone aggregate) as in subbase, floor and pavings complete all as specified and directed.
M&L for 15 thick Endura Acid and alkali resistant Industrial tile size (300mmx300mm) any colour with grey cement and pigment set, jointed and pointed on neat cement slurry as in floors including 20mm thick screed bed with bedding layer in CM (1:6) complete all as specified and directed. Make: Johnson, somany, kajaria OR equivalent
M&L for 10 to 12mm thick designer parking tiles of size exc. .09 Sqm but n.exc. 0.16 Sqm any colour and shape with grey cement and pigment set, jointed and pointed on neat cement slurry as in floors including 15mm thick screed bed with bedding layer in CM (1:6) complete all as specified and directed. Make: DUROTA, JOHNSON (Endura), ORIENT.
M&L for 60mm thick machine pressed precast coloured concrete interlocking paver block, Glossy finish any shape and size and colour confirming to IS 15658-2006, M-35 Grade complete all as specified and directed. Make: ISI Marked as Approved by GE.
All as per item No 23 but except paver blocks
M&L for sand/stone dust filling under floor watering and levelling to receive paver blocks. complete all as specified and directed.
M&L for factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete.
M&L for PCC 1:2:4 Type B-1 (using 20mm graded Stone aggregate) as in flooring, kerbs, haunching, copping, etc complete all as specified and directed.
M&L 100mm th PCC 1:2:4 Type B-1 (using 20mm graded Stone aggregate) as in hard standing, finishing cement concrete surface even and smooth without using extra cement complete all as specified and directed.
M&L for Forming Contraction (Dummy) joints 65mm deep x 10mm wide, filled with sealing compound Grade 'A' and all as specified and directed.
M&L for Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws including Dismantling of existing plain or corrugated steel /AC Sheet complete all as specified and directed.
M&L for Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, Ridge, valley/ gutter fixed with self tapping screws including Dismantling of existing Plain or corrugated steel /AC Sheet complete all as specified and directed.
M&L for brick work with sub class 'B' bricks straight or curved on plan exc 6 M mean radius built in CM (1:6) complete including demolition of brick work of any description and in any position built in cement mortar including all quoins, arches pillar etc including disposal of rubbish complete all as specified and directed
All as per item No 32 above but except Bricks.
M&L for 15mm thick rendering fare face of brick/stone masonry walls in CM 1:4 finished even and smooth (without using extra cement) complete all as specified and directed.
M&L for 15mm thick rendering fare face of brick/stone masonry walls in CM 1:4 finished even and smooth without using extra cement complete all as specified and directed including taking down cement plaster on brick surface or stone surfaces including raking out joints hacking for key, scrubbing down with water etc complete all as specified and directed.
M&L for Preparation of newly plaster surface of wall and applying two coat of distemper oil emulsion over a coat of chalk whitening (preparatory to distempering) white or tinted as approved all as specified and directed.
M&L for Preparation of newly plastered surface and applying two coat of weather coat exterior emulsion @ 1.43 litre/ 10 sqm white or tinted over a coat of primer as approved and including priming coat of exterior primer applied @ 0.90 litre/ 10sqm over new surfaces. complete all as specified and directed
M&L for Providing and injecting chemical emulsion for Post Constructional Antitermite Treatment along the internal/ external wall and floor junctions below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes with coloured CM 1:2 to match with the existing floor complete all as specified and directed.
M&L for Providing and injecting chemical emulsion for Post Constructional Antitermite Treatment of soil under existing floors using emulsion @ one litre per hole, 300mm apart including drilling and plugging 12mm dia holes with CM 1:2 to match the existing floors complete all as specified and directed.
M&L for Providing and injecting chemical emulsion for Post Constructional Antitermite Treatment at points of contact of wood work by chemical emulsion (in oil or kerosene based solution) @ 0.5 litre/hole by drilling 6mm dia holes at a downward angle of 45 degree at 150mm centre to centre and plugging holes with CM 1:2 to match the existing surface complete all as specified and directed.
M&L for Complete removal of existing treatment on walls (any number of layers) by scrapping with steel scrappers and applying a coat with putty to make the surface even and smooth matching to the adjacent wall surfaces and applying two coats distemper oil emulsion with roller over a coat of primer all as specified and directed.
M&L for Preparation of old decorated surface of wall include brooming down with steel wire brushing; scrapping down smoke soot, moulds, mass and efflorescent salts and trading oil and greasy spots, including filling the cracks and depressions and applying one coat of distemper oil emulsion with roller white or tinted as approved complete all as specified and directed.
All as per item No 42 here-in-before but on ceiling surface complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description at any place not otherwise complete all as specified and directed.
S & F MS tubular pipes as in vertical post, rafter & purlins as in sheds/canopy cut to reqd shape, welding drilling and including bending as necessary, gusset plates, riveting, etc confirming to Fe-290 Gde-E-165complete all as specified and directed.
M&L for preparation of new steel surfaces exc 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed..
Taking down carefully aluminium /copper point wiring (light, fan, switch & power) complete including fittings such as switches, ceiling rose, pendent, by unscrewing from board ,out let box, fitting and fixture such as bulk head fitting, sketch fittings and making good the disturbed surfaces of walls floors etc all as directed.
M&L for point wiring with stranded copper conductor 1.5. Sqmm 1100 Volts grade FRLS PVC insulated and unsheathed including ISI marked PVC casing capping of required sizes as indicated including all accessories, copper conductor cable 1.5 Sqmm insulated and unsheathed PVC cables as earth wire, trminal boxes closed recossed type. PVC Plastic board all as required as specified and directed for the following :- (a) One light/ Fan point controlled by one way switch.
(b) One 5 Amps switch socket combination on independent board.
(c) One 5 Amps socket on same board with other switches.
All as per item No-48 here in above but 2.5 Sqmm stranded copper conductor and independent board for 15 Amps switch/ socket point as directed.
S&F switch piano flush type single pole one way 5 Amps 230 V ISI marked complete all as specified and directed.
S&F switch socket out let 3 pin 5 Amps flush type 230 Volts multipurpose, ISI marked complete all as specified and directed.
S&F switch socket out let 5 Amps and 15 Amps multipurpose( 3 Pin 15 Amps and one pin 5 Amps controlled by one switch.) ISI marked complete all as specified and directed.
S&F fan regulator Electronic Step type (min 5 steps) 2module, 100W ISI marked by removing old u/s resistance type fan regulator including necessary connection in existing laminated switch board by making necessary holes etc., complete all as specified and directed by Engineer-in-Charge.
S&F lamp holder insulated body with back plate for battern fittings complete all as specified and directed by Engr-in-charge.
M&L for sub main wiring in replacement using two single core PVC insulated, unsheathed stranded copper conductor cable of size 4 Sqmm FRLS of voltage rating 1100 Volts drawn in and including surface in PVC casing caping with standard accessories, along-with one run of PVC (green colour) insulated, unsheathed, stranded copper conductor of size 4 Sqmm as earth continuity conductor complete all as specified and directed. NOTE: Two run of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit.
M&L for sub main wiring in replacement using two single core PVC insulated, unsheathed stranded copper conductor cable of size 6 Sqmm FRLS of voltage rating 1100 Volts drawn in and including surface in PVC casing caping with standard accessories, along-with one run of PVC (green colour) insulated, unsheathed, stranded copper conductor of size 6 Sqmm as earth continuity conductor complete all as specified and directed. NOTE: Two run of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit.
M&L for sub main wiring in replacement using two single core PVC insulated, unsheathed stranded copper conductor cable of size 4 Sqmm, FRLS of voltage rating upto and including 1100 Volts drawn in existing conduit along-with one run of PVC (green colour) insulated, unsheathed, stranded copper conductor of size 4 Sqmm as earth continuity conductor complete all as specified and directed. Note:- Two run of single core PVC cable with one run of earth conductor shall be measured as one unit.
M&L for sub main wiring in replacement using two single core PVC insulated, unsheathed stranded copper conductor cable of size 6 Sqmm FRLS of voltage rating upto and including 1100 Volts drawn in existing conduit along-with one run of PVC (Green colour) insulated , unsheathed, stranded copper conductor of size 6 Sqmm as earth continuity conductor complete all as specified and directed. Note:- Two run of single core PVC cable with one run of earth conductor shall be measured as one unit
Supply, fixing, connecting & testing in repair of sheet metal enclosures single pole and neutral with a two pin earth plug and socket complete with one single pole 20 amp MCB complete all as specified and directed.
Supply, fixing, connecting & testing in repair of sheet metal enclosures (IP-54 Protection) triple pole and earth with three pin earth plug and socket complete with one TPN 32 Amp MCB complete all as specified and directed.
Supply, fixing, connecting & testing in repair of sheet metal enclosures double door (IP-42 Protection), triple pole and neutral, 4 way DBs for using MCBs / MCB isolators with having aluminium bus bars suitable for 200 Amps rating complete all as specified and directed.
All as per item No.61 here-in-before but distribution board single pole and neutral, 12 way complete all as specified and directed.
All as per item No.61 here-in-before but distribution board single pole and neutral, 8 way complete all as specified and directed.
All as per item No.61 here-in-before but distribution board single pole and neutral, 4 way complete all as specified and directed.
Supplying and fixing in replacement of decorative surface mounting 36 watt LED full out put luminaries which provides soft light glare free symmetrical illumination suitable for Armstrong/Grid ceiling, white powder coated sheet steel housing with paralite P5 square parabolic louver block in metallic perforated frame for low glare, aluminium reflector and accessories ,connecting the same to electric source with and including copper conductor 23/0.0076 flexible twisted twin core cable , including all accessories and fixing arrangements for fixing the 2x2 LED light fitting to false ceiling complete all as specified and directed by Engineer-in-Charge.
Supply& Fixing in replacement of LED Batten fittings 1x20 Watt complete with round block etc, incl PVC gutties and flexible wire and connecting to ceiling rose complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of 10 Watt LED bollard light one meter long with Opel acrylic diffuser and IP-65 protection including necessary PCC base work complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of LED flood light 70 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and directed by Engr-in-charge.
All as per item No. 68, but LED flood light 100 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and directed by Engr-in-charge.
All as per item No. 68, but LED flood light 120 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and directed by Engr-in-charge.
Supply and fixing in replacement of post top lantern LED type 40 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete all as specified and directed by Engr-in-charge.
Supply and fixing in replacement of LED building security/street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed by Engineer-in-Charge.
S & F in replacement of LED light fitting 1x9W/1X10W bulk head luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed by Engineer-in-Charge.
M/S NIRMAL SINGH DHANJAL
M/S YOGANSH CONSTRUCTION CO.
lodhi builders
M/S LAKSHYA CONSTRUCTIONS
M/s Anjali Construction
M/s Manish Contractor
m/s vikash Engineers
M/s Gulshan and Brothers
SHRI RAM CONSTRUCTION
stage.html
html • 0.08 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .