Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.3 CrAccepted-AOC PLOT NO HIG 7 CHUNVATI LANE GOPALGAN BALASORE 756001 | BALESHWAR | ODISHA | 756001 | ₹8.3 Cr | L1 | Accepted-AOC L1 bidder |
| 2 | L2₹8.5 Cr+₹21.8 L (2.64%)Rejected-Finance | ₹8.5 Cr+₹21.8 L (2.64%) | L2 | Rejected-Finance Not being L1 bidder |
| 3 | L3₹8.6 Cr+₹36.2 L (4.39%)Rejected-Finance | ₹8.6 Cr+₹36.2 L (4.39%) | L3 | Rejected-Finance Not being L1 bidder |
| 4 | L4₹9.0 Cr+₹72.3 L (8.75%)Rejected-Finance | ₹9.0 Cr+₹72.3 L (8.75%) | L4 | Rejected-Finance Not being L1 bidder |
| 5 | L5₹10.0 Cr+₹1.7 Cr (20.5%)Rejected-Finance | ₹10.0 Cr+₹1.7 Cr (20.5%) | L5 | Rejected-Finance Not being L1 bidder |
Tender Value
₹9.2 Cr
EMD Value
₹7.9 L
Closing Date
9 Apr 2024, 6:00 pmClosed
CE RND Delhi
HQ CE RnD Delhi, Probyn Road, Timarpur, Delhi-1100054
PROVN OF CIVIL WORKS FOR CONSTRUCTION OF BLDG AS EXTENSION CONTROL CENTRE FOR AUGUMENTATION OF TECHNICAL FACILITIES AT ITR CHANDIPUR UNDER GE (I) RnD CHANDIPUR
2024_MES_638640_1
CE RND/DLI-43/CHANDI/2023-24
Open Tender
Civil Works
Lump-sum
670 days
Chandipur
Please refer tender documents
7 documents required · 7 mandatory
₹3,000
GE I RND CHANDIPUR
₹7.9 L
Yes
4 Jun 2024
23 Jan 2024
16 Apr 2024
23 Jan 2024
9 Apr 2024
26 Mar 2024
Amount
Schedule 'A' Section-I, Section-II(Part-I) to Section-XIII (Part-I), under Ser No. 1.01 to 1.13 are prepriced by MES based on SSR (Pt-II)-2020
Lump sum price worked out by the Contractor for “Building work” as listed in Schedule ‘A’ Section-I
Lump sum price worked out by the Contractor for “Excavation and Earth Work” as listed in Schedule ‘A’ Section-II (Part-I)
Lump sum price worked out by the Contractor for “INTERNAL WATER SUPPLY” as listed in Schedule ‘A’ Section- III (Part-I)
Lump sum price worked out by the Contractor for “INTERNAL ELECTRIFICATION” as listed in Schedule ‘A’ Section-IV (Part-I)
Lump sum price worked out by the Contractor for "SEWAGE DISPOSAL” as listed in Schedule ‘A’ Section- V (Part-I)
Lump sum price worked out by the Contractor for "ROAD, PATH & HARDSTANDING ” as listed in Schedule ‘A’ Section- VI (Part-I)
Lump sum price worked out by the Contractor for "EXTERNAL WATER SUPPLY” as listed in Schedule ‘A’ Section- VII (Part-I)
Lump sum price worked out by the Contractor for "EXTERNAL ELECTRIFICATION & CHEMICAL EARTHING” as listed in Schedule ‘A’ Section- VIII (Part-I)
Lump sum price worked out by the Contractor for "FIRE FIGHTING SYSTEM” as listed in Schedule ‘A’ Section- IX (Part-I)
Lump sum price worked out by the Contractor for "FIRE ALARM SYSTEM” as listed in Schedule ‘A’ Section- X (Part-I)
Lump sum price worked out by the Contractor for "SHIFTING OF COOLING TOWER" as listed in Schedule ‘A’ Section- XI (Part-I)
Lump sum price worked out by the Contractor for "LIGHTNING PROTECTION” as listed in Schedule ‘A’ Section- XII (Part-I)
Lump sum price worked out by the Contractor for "AIR CONDITIONING WORK” as listed in Schedule ‘A’ Section- XIII (Part-I)
SCHEDULE `A' Section-II (PART - II) (Excavation and Earth work) NOTE: - Excavation/Earth work required for Section-III (Part-I & Part-II) to Section XII(Part-I & Part-II), & Section XV shall be measured and paid for under this Section of Schedule ‘A’ if specifically not mentioned in the item
Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth upto 30 cm measured at a height of 1 m above ground level and removal of rubbish upto distance of 50 mtr outside the periphery of the area cleared.
SCHEDULE `A' Section-III (PART-II) (INTERNAL WATER SUPPLY)
Providing and fixing chlorinated Polyvinyl Chloride (CPVC) pipes of 25 mm nominal size having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings including fixing the pipe with clamp at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement, testing of joints in external work complete all as specified and directed.
Providing and fixing chlorinated Polyvinyl Chloride (CPVC) pipes of 20 mm nominal size having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings including fixing the pipe with clamp at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement, testing of joints in external work complete all as specified and directed.
Providing and fixing chlorinated Polyvinyl Chloride (CPVC) pipes of 15 mm nominal size having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings including fixing the pipe with clamp at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement, testing of joints and making good the wall complete all as specified and directed.
S&F CP brass long body bib tap 15 mm bore, fancy type with wall flange complete all as specified and directed. Make: - CON-107KN of Jaquar/F730011 of Hindware/F2006152 of Cera/G3005A1 of Parryware or equivalent.
S&F CP brass auto closing urinal valve 15 mm bore, fancy type with wall flange and CP connecting pipes complete all as specified and directed. Make: - PRS-077 of Jaquar/F310016 of Hindware/F9020201 of Cera/G2007A1 of Parryware or equivalent.
S&F health faucet (ABS Body) with 8mm dia, 1.00 to 1.50 m long spirochrome flex tube & wall hook complete all as specified and directed. Make: - ALD-587 of Jaquar/F160110 of Hindware/F8030106AB of Cera/T9875A1 of Parryware or equivalent.
SCHEDULE `A' Section-IV (PART-II) (INTERNAL ELECTRIFICATION)
M & L for Sub main wiring with four single core 16 Sqmm (nominal area) PVC insulated copper conductor FRLSH, multi stranded, unsheathed 1100 volts grade IS-694 marked in PVC conduit including two single core 6 Sqmm copper conductor cable FRLSH as earth wire complete all as specified and as directed. NOTE : - Four runs of 16 sqmm and 2 runs of 6 sqmm copper conductor and one run of conduit shall be measured as one run length
M & L for Sub main wiring with four single core 10 Sqmm (nominal area) PVC insulated copper conductor FRLSH, multi stranded, unsheathed 1100 volts grade IS-694 marked in PVC conduit including two single core 6 Sqmm copper conductor cable FRLSH as earth wire complete all as specified and as directed. NOTE : - Four runs of 10 sqmm and 2 runs of 6 sqmm copper conductor and one run of conduit shall be measured as one run length.
M & L for Sub main wiring with four single core 6 Sqmm (nominal area) PVC insulated copper conductor FRLSH, multi stranded, unsheathed 1100 volts grade IS-694 marked in PVC conduit including two single core 6 Sqmm copper conductor cable FRLSH as earth wire complete all as specified and as directed. NOTE : - Six runs of 6 sqmm copper conductor and one run of conduit shall be measured as one run length.
S&F Sheet metal enclosure DB VTPN 415 Volt 4 way double door type with incoming MCCB 63 A, 200 Amps rated bus bar for fixing MCB complete all as specified and as directed.
S & F Sheet metal enclosure DB SPN 240 Volt 6 way double door type with 200 Amps rated bus bar for fixing MCB complete all as specified and as directed.
S & F MCB Triple Pole 415 Volts, 5 Amps to 32 Amps , 10 KA rapturing capacity. 'C' series complete all as specified.
S & F MCB Single Pole Neutral 240 Volts , 5 Amps to 32 Amps , 10 KA rapturing capacity. 'C' series complete all as specified.
Supply and fixing wall mounted swinging type air circulator fan 450 mm (min) sweep fibre body and blade with double bearing, AC single phase 230 volts, including electrical connection with twisted three core PVC insulated flexible cord of size 0.75 Sqmm copper conductor from ceiling rose/plug socket complete all as specified and as directed.
Supply and fixing of LED cadila batten 22W, LED T5 indoor batten tube light with Aluminium Extrusion Housing, with PC diffuser, lumen efficiency not less than 120 Lumen per watt and electronic driver( >80% efficiency level & THD< 10%) , power factor shall be >0.95 complete and including all other standard accessories as per manufacture instructions ,internally pre-wired including connecting up with twin core 0.75 sq. mm copper conductor flexible wire/cable. Life expectancy of LED's minimum 50,000 burning hrs, warranty of complete luminaries fitting shall not less than five years complete all as specified and directed .
Supply and fixing of LED batten surface/ceiling mounting box type light fitting 40Watt, with driver indoor batten tube light with Aluminium Extrusion Housing, with PC diffuser, lumen efficiency not less than 120 Lumen per watt and electronic driver( >80% efficiency level & THD< 10%) , power factor shall be >0.95 complete and including all other standard accessories as per manufacture instructions ,internally pre-wired including connecting up with twin core 0.75 sq. mm copper conductor flexible wire/cable. Life expectancy of LED's minimum 50,000 burning hrs, warranty of complete luminaries fitting shall not less than five years complete all as specified and directed .
Supply and fixing of LED 'Batten integrated LED channel' surface/ceiling mounting(suspended from ceiling) box type light fitting 9/10Watt with LED Lamp , driver and made of integrated sleek extruded polycarbonate channel with white acrylic cover & high power LED’s as light source with LED fitting system lumen efficiency not less than 95% Lumen per watt and electronic driver( >80% efficiency level & THD< 10%) , power factor shall be >0.95 complete and including all other standard accessories as per manufacture instructions ,internally pre-wired including connecting up with twin core 0.50 sq. mm copper conductor flexible wire/cable. Life expectancy of LED's minimum 50,000 burning hrs, warranty of complete luminaries fitting shall not less than five years complete all as specified and directed .
Supply and fixing of LED surface/ceiling mounting 2' x 2' LED luminaire light fitting 30Watt , lumen, lumen efficiency not less than 125 lm/w Lumen per watt and electronic driver( >80% efficiency level & THD< 10%), with driver and made of epoxy powder coated CRCA housing with high quality polycarbonate opal diffuser cover including connecting up with twin core 0.75 sq. mm copper conductor flexible wire/cable. Life expectancy of LED's minimum 50,000 burning hrs, warranty of complete luminaries fitting shall not less than five years. colour temperature need to confirm before placing of order complete all as specified and directed .
Supply and fixing of LED surface/ false ceiling mounting 1' x 1' LED luminaire light fitting 12 Watt, lumen, lumen efficiency not less than 110 lm/w Lumen per watt and electronic driver( >80% efficiency level & THD< 10%), with driver and made of epoxy powder coated CRCA housing with high quality polycarbonate opal diffuser cover including connecting up with twin core 0.75 sq. mm copper conductor flexible wire/cable. Life expectancy of LED's minimum 50,000 burning hrs, warranty of complete luminaries fitting shall not less than five years. colour temperature need to confirm before placing of order, complete all as specified and directed .
Supply , Fixing & testing of Vector LED Building Security Light (IP66 protected) 45 Watt, driver and made of pressure die-cast aluminium housing, lumen efficiency not less than 110 lm/w Lumen per watt with inbuilt protection against lightning, over voltage, short circuit and surge/spike protection upto 5 KV ensuring longer life (THD <10%, PF shall be > 0.95, colour temperature 5700±300 K), Life expectancy of LED's minimum 50,000 burning hrs, warranty of complete luminaries fitting shall not less than five years complete all as specified and directed.
M&L for RJ-11 telephone/LAN socket with transparent shutter 1 module along with flush metal box 1 module and front cover plate 1 module complete all as specified and as directed.
M& L for TV socket with transparent shutter 1 module along with flush metal box 1 module and front cover 1 module complete all as specified and as directed.
Supply and fixing of MS / GI hot dipped / powder coated perforated type Cable Trays 14 SWG of size 100 mm x 50 mm H with Tee, cross, horizontal / vertical bend and reducer complete all as specified and as directed.
Supply and fixing of MS / GI hot dipped / powder coated perforated type Cable Trays 14 SWG of size 150 mm x 50 mm H with Tee, cross, horizontal / vertical bend and reducer complete all as specified and as directed.
Supply and fixing of MS / GI hot dipped / powder coated perforated type Cable Trays 14 SWG of size 225 mm x 50 mm H with Tee, cross, horizontal / vertical bend and reducer complete all as specified and as directed.
SCHEDULE `A' Section-V (PART-II) (SEWAGE DISPOSAL)
M & L for Construction of brick masonry manhole with old sized bricks of class designation 75 in cement mortar 1:4 (1 cement : 4 coarse sand) with R.C.C. top slab of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement complete as directed. Inside manhole size 90 cm x 80 cm and 45 cm deep including C.I cover with frame (light duty) 455 x 610 mm internal dimensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) including necessary excavation complete all as specified & shown in drawings.
Extra for depth for manhole of size 90cm x 80 cm With old sized bricks class designation 75
SCHEDULE `A' Section-VI (PART-II) (ROAD, PATH & HARDSTANDING)
Material and labour for dry lean cement concrete sub base over a prepared sub-grade with coarse and fine aggregate conforming to IS:383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per specifications, cement content not to be less than 150 Kg/cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, for all leads & lifts, laid with a mechanical paver, compacting with 8-10 tonne vibratory roller, finishing and curing etc. complete all as specified & directed.
Material and labour for granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading i n uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. With material conforming to Grade-I (size range 75 mm to 0.075 mm) having CBR Value-30 complete all as specified & directed.
Providing and filling 50 mm deep PU (Polyurethane) based joints sealer of approved make for sealing of joints in roads/pavements etc complete all as specified & directed.
SCHEDULE `A' Section-VII (PART-II) (EXTERNAL WATER SUPPLY)
Material and Labour for Cutting existing CI/DI/GI tubing of size upto 150 mm dia for alterations or additions or for insertion of new tees, branches complete all as specified and directed.
M & L for Supply, laying, connection and testing of 100 mm dia Ductile Iron Class K-9 pipes conforming to IS : 8329 in trench including jointing etc. complete all as specified and directed
M & L for Supply, laying, connection and testing D.I. specials of class K-12 suitable for push-on/Mechanical jointing as per IS : 9523 with all necessary rubber gasket, necessary bolts, nuts, washers etc. all as specified and directed
Making connection of G.I. distribution branch of 50 to 80 mm nominal bore from CI/DI/G.I. main of any size by providing and fixing tee, including cutting and threading welding the pipe etc. complete all as specified and directed.
M&L for construction of masonry Chamber 90x90x100 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ), including necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete with common burnt clay old size bricks of class designation 7.5 complete all as specified and as directed.
SCHEDULE `A' Section-VIII (PART-II) (EXTERNAL ELECTRIFICATION AND CHEMICAL EARTHING)
Supply, installation, commissioning and testing rated voltage 11 KV/System voltage 12KV, 250 MVA rupturing capacity, overload and earth fault protection, 3 phase 50 cycle (50 Hz) totally enclosed metal clad switch gear Vacuum Circuit Breaker floor mounted with common copper tinned bus bar indoor type 400 Amps capacity triple pole HT control panel confirm to IS-3427 totally enclosed extendable pattern horizontally/vertically isolated dust and vermin proof, Horizontal draw out type with grounded neutral system & equipped with the following equipment including internal connections, control fusses/MCB etc. complete all as specified and as directed. :- (i) One set of 3 phase 400 Amps air insulated tinned copper bus bar with insulated colour coding. (ii) One set of side frame for housing for circuit breaker carriage. (iii) One set of mechanical interlock and automatic shutter gear. (iv) One 400 Amps triple pole 250 MVA rupturing capacity Vacuum circuit breaker with automatic dropout and manually operated spring closed mechanism operating by 230 volt 50 htz single phase electric motor of suitable rating complete with contacts, close/neutral/trip switches, closing coil, test/isolation switches with internal connections and fully confirmed to IS-13118, trunk type mechanically ON/OFF indicator, and degree of protection-IP4X. (v) One circuit breaker carriage complete with self contained raising & lowering mechanism for isolation purpose. (vi) cable boxes suitable for HT 11 KV XLPE 3 core cable upto 120 Sqmm either side. (vii)One set of 3 Nos resin cast in capsulated twin secondary current transformer of dual ratio 50-25/5-5 Amps and accuracy class 0.5 for metering and 5P10 for protection of suitable burden for protection as well as metering.
Supplying and installing 375mm width x 50mm depth x 2.0 mm thickness perforated hot dipped galvanised iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5% in convenient sections, joined with connectors, suspended from the ceiling with GI suspenders/fixed to wall including GI bolts & nuts etc., complete all as specified and as directed.
S&F loop in- loop out junction box, Maintenance free, tamper and rot proof, Fire retardant- Class FV-0 as per IS:11731 Part-II, termite resistant, IP55 with approx. internal dimension 200x140x95mm (HxWxD) or next higher size made out of FRP sheet, Cable entry from top-1 No and bottom-2 Nos with weather proof canopy including din rail mounted Single pole MCB, 20 Amps rated, 4 Way connectors for 3 phase and neutral incoming/out going, mounted in the box, fixing on steel tubular poles including necessary aluminium clamps, suitable double compression cable glands, lugs and GI nut and bolts complete all as specified and directed .
Supply, laying, connecting and testing of PVC insulated flexible multicore round copper conductor cable of size 3 core 2.5 Sqmm including necessary end connector fixed along with pole structure etc. with all fixing & connecting accessories complete all as specified and directed.
Supply, install, testing & commissioning of LT control panel board "out-door type" of size 1500 mm (height) x 1200 mm (breadth) x 500 mm (depth) (minimum dimensions) factory fabricated CPRI approved (type-tested) with suitable neoprene rubber gasket to make it completely dust & vermin proof & degree of protection not less than IP-55 & general construction confirming to IS-13947, double door, front & back openable. The panel shall be provided with ventilation facility in the form of louvers for better heat dissipation & tinned copper bus-bar wrapped with coloured PVC tape/sleeves of rating in conformity to the Incoming ACB/MCCB rating. The panel board shall be fabricated out of 3.15 mm thick (for outer portions) & 2.0 mm thick (for inner portions) CRCA sheet duly pre-treated & powder coated, supporting angle iron frame & MC channel base suitable for 3 Ph, 4 wire system 415/440 volts grade incl complete internal wiring with not less than 2.5 sqmm copper wire incl cable glands of suitable sizes incl suitable PCC (1:3:6) type C-2 foundation, necessary earthwork (if any) complete all as specified & as directed with & incl the following accessories : BUS-BAR & INTERNAL CONNECTIONS : The bus-bars shall be made up of 04 Nos high grade tinned copper 400 A rated, duly insulated with 1100 V grade standard colour coded PVC sleeves & rigidly mounted on suitable sized "F" class insulators of non-hygroscopic, non-combustible, all internal connections from main bus-bars to switch gears etc.
Supply, install, testing & commissioning of LT control panel board "out-door type" of size 1500 mm (height) x 1200 mm (breadth) x 500 mm (depth) (minimum dimensions) factory fabricated CPRI approved (type-tested) with suitable neoprene rubber gasket to make it completely dust & vermin proof & degree of protection not less than IP-55 & general construction confirming to IS-13947, double door, front & back openable. The panel shall be provided with ventilation facility in the form of louvers for better heat dissipation & tinned copper bus-bar wrapped with coloured PVC tape/sleeves of rating in conformity to the Incoming ACB/MCCB rating. The panel board shall be fabricated out of 3.15 mm thick (for outer portions) & 2.0 mm thick (for inner portions) CRCA sheet duly pre-treated & powder coated, supporting angle iron frame & MC channel base suitable for 3 Ph, 4 wire system 415/440 volts grade incl complete internal wiring with not less than 2.5 sqmm copper wire incl cable glands of suitable sizes including suitable PCC (1:3:6) type C-2 foundation , necessary earthwork (if any) complete all as specified & as directed with & incl the following accessories : BUS-BAR & INTERNAL CONNECTIONS : The bus-bars shall be made up of 04 Nos high grade tinned copper 400 A rated, duly insulated with 1100 V grade standard colour coded PVC sleeves & rigidly mounted on suitable sized "F" class insulators of non-hygroscopic, non-combustible, all internal connections from main bus-bars to switch gears etc.
M&L for Cement plaster skirting 18 mm thick up to 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement complete all as specified and directed .
Supplying and fixing cable route marker with 10cm X10 cm X5 mm Each 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground with and including PCC 1:2:4 as required complete all as specified and directed.
Supply and fix of 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. Including insulator saddle etc. as required complete all as specified and directed
Supply and fix of 25 mm X 5 mm G.I. strip buried in ground for connections etc. as required complete all as specified and directed .
Material & Labour for fixing of 25 mm X 5 mm copper strip on surface or in recess for connections etc. including suitable insulated clamp at regular interval not more than one meter of distance complete all as specified and as directed.
Lifting of existing HT 11 kV grade cable of size upto 120 Sqmm from the existing masonary duct/trench and re-laying the same in another trench/duct as required at site complete all as specified and as directed by Engr-in-Charge.
Lifting of existing LT 1100V grade cable of size upto 185 to 400 Sqmm from the existing masonary duct/trench and re-laying the same in another trench/duct as required at site complete all as specified and as directed by Engr-in-Charge.
Lifting of existing LT 1100V grade cable of size upto 120 Sqmm from the existing masonary duct/trench and re-laying the same in another trench/duct as required at site complete all as specified and as directed by Engr-in-Charge.
Laying and fixing of LT cable 1100V grade of size upto 35 Sqmm (Clamped with 1mm thick saddle) on cable tray as required complete all as specified and as directed by Engr-in-Charge.
SCHEDULE `A' Section-IX(PART-II) (FIRE FIGHTING SYSTEM)
M&L for cutting bituminous road portion and making good the same including supply of extra quantities of materials i.e. bitumen, aggregate, moorum screening, red bajri complete all as specified and as directed.
M& L for making connection of MS. distribution branch from existing MS main of size 150 mm dia by providing and fixing tee, including cutting and threading/welding the pipe etc. complete all as specified and as directed.
Providing coating & wrapping with two coats of coal tar hot black paint and two wraps of reinforced fibre glass tissue or bituminised hessian or providing 4 mm thick tar based polymeric corrosion protection tape over a coat of red oxide primer as directed including providing 150 mm thick fine sand layer all round the pipe & hydrostatic testing of the complete pipe work , complete all as specified and as directed.
Supplying and fixing Single headed external yard hydrant valve with 1 No. 63 mm dia instantaneous FM Gunmetal coupling and cast iron wheel, ISI marked, conforming to IS 5290 (type A) with blank Gunmetal cap and chain complete all as specified and as directed.
Synthetic fibre circular woven jacketed rubber lined RRL fire hose with male female gunmetal coupling Reddish brown delivery having 38Kg/cm² burst pressure, 28Kg/cm² proof pressure, 14Kg/cm² working pressure as per 1S:636 (ISI Marked) Type A in 15 Meters length, 63mm dia duly copper via bounded two coupling pair of male female parts any duly instantaneous type, 63mm size as per 15:903 (ISI Marked) complete all as specified and as directed.
Supplying and fixing first-aid Hose Reel 30 Mtr in length with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 20 mm nominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket complete all as specified and as directed.
S & F 25mm Air release valve as per IS:14845 ISI Marked complete all as specified and as directed.
Supply, installed, testing and commissioning of electric driven pressurisation pump (Terrace pump) 450 Ipm at 35 m Head including eclectic motor of suitable capacity complete all as specified and as directed.
S&F triple layer Polyethylene water storage tank with cover ISI marked white colour with all necessary connection and suitable locking arrangement of capacity 10000 litres including PCC platform arrangement complete all as specified and as directed.
Supply & fixing of pressure switch in M.S. pipe line including connection etc. complete all as specified and directed.
Supplying & laying of 2x1.5 sqmm fire survival armoured cable, 600/1000V rated with annealed copper conductor having glass mica fire barrier tape covered by an extruded layer of Cross Linkable Ethylene Propylene Rubber (EPR) insulation and LSZH inner bedding, steel wire armouring & LSZH outer sheath complete all as specified and directed.
SCHEDULE `A' Section-X (PART-II) (FIRE ALARM SYSTEM)
Supplying, installation, testing & commissioning of manual call box of ABS type in surface/recess with stainless steel chain & hammer assembly complete with glass and push button etc. complete all as specified and directed.
Supplying, installation, testing & commissioning fire alarm sounder with flash facility to make announcement, mounted in M.S. box (16 SWG) with hinged cover plate & suitable for operation with amplifier i/c line matching transformer etc. complete all as specified and directed.
Supplying, installation, testing & commissioning response indicator on surface/recess MS box having two LEDs metallic cover complete with all connections etc. complete all as specified and directed.
Supplying and drawing of Single pair, 2-core, 1.5 sqmm cable Fire Retardant PVC insulated copper conductor cable in the surface / recessed steel conduit including connections and interconnections etc. complete all as specified and directed.
Supplying and fixing 25 mm dia MS flexible pipe with PVC coating along with all ancillaries and accessories like coupler etc. complete all as specified and directed.
Supplying and fixing of 20 mm sizes of steel conduit along with all type accessories in surface/recess including civil work, painting in case of surface conduit, complete all as specified and directed.
Supplying and fixing Power Supply system compatible with 24V, 160 AH with battery backup for External Power for Hooter complete all as specified and directed.
SCHEDULE `A' Section-XI (PART - II) (SHIFTING OF COOLING TOWER)
Disconnecting of existing cooling tower of any capacity and shifting of the same after repair, and erection, testing commissioning of cooling tower complete with all necessary structure repair work, fasteners and other required items as required for operation of AC plant complete all as specified and directed.
Supply and install perforated painted with powder coating MC cable tray with perforation not more than 17.5% in convenient section, joined with connectors, suspended from the ceiling with MS suspenders including bolts & nuts painting suspenders etc as required of size 100mm widthx50mm depthx1.6mm thick complete all as specified and directed.
SCHEDULE `A' Section-XII, (Pat-II) (LIGHTNING PROTECTION)
Providing and fixing of lightning conductor finial, made of 25mm dia 300mm long, GI tube, having single prong at top, with 85mm dia 6mm thick GI base plate including holes etc. complete all as specified and directed. Note: GI pipe for mounting of air termination rod shall be measured & paid separately.
M & L for Jointing copper/GI tape (with another copper/GI tape, base of the finial or any other metallic object) by riveting/nut bolting/sweating and soldering etc. complete all as specified and directed.
Supply and fixing GI strip 20mm x 3mm thick on parapet or surface of wall for lightning conductor with insulator complete as required (for horizontal run) complete all as specified and directed.
Supply and fixing GI strip 20mm x 3mm thick on parapet or surface of wall for lightning conductor complete as required (for vertical run) complete all as specified and directed.
Providing and fixing testing point terminal block, made of 20mmx3mm thick GI strip 125mm long with 4 nos. of GI bolts, nuts, check nuts and spring washers with box enclosure etc. complete all as specified and directed.
Supplying and laying of 63 mm DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to 1S 14930, Part Il complete with fitting and cutting, jointing etc. in the existing trench/wall, complete all as specified and directed.
SCHEDULE `A' Section-XIII, PART-II (AIR CONDITIONING WORK)
Supply, install, testing and commissioning voltage stabilizer copper wound electronic including connection to air conditioner complete suitable for single phase input voltage working range 150-290 volts 50Hz AC with stable output of 230 volt supply with low voltage high voltage cut off & time delay arrangement of capacity 5.0 KVA output, voltmeter with suitable arrangement for fixing at wall at site complete all as specified and directed .
SCHEDULE `A' Section-XIV, (RO WATER COOLER)
Supply, installation, commissioning of Water cooler fully stainless steel, electric driven single phase having approx. storage 80 litres and nominal cooling capacity 60 litres with inbuilt stabilizer and inbuilt RO+UV complete all as specified and directed.
SCHEDULE `A' Section-XV (DG SET) (To be quoted by the tenderer)
Supply, installation, testing and commissioning of silent type Diesel Engine driven Generating set along with acoustic enclosure duly approved by Nodal agency ARAI Pune or equivalent, fully wired 415 volts ± 5% AC 3 phase, 4 wire 50 Hz having capacity 200 KVA continuous rating, power factor 0.8 (lagging) and connections as per IE Rules, duly certified by agencies/labs designated latest technology as per CPCB -IV norms for noise and sound pollution level. DG Set mounted on common base plate with anti vibration pad mounting, etc. floor mounted including PCC foundation as per manufacturer's instructions complete all as specified & directed consisting the following :- (a) Diesel Engine The engine shall be multi-cylinder four stroke, 1500 RPM, Radiator water/ coolant cooled turbo charged complete with instrument panel electronic governor, starting battery with lead, exhaust pipe and silencer pipe with suitable insulation by glass wool and aluminium cladding, safety devices and other standard fitting etc. complete as per IS-10001/1002 part -II 1980 and BHP suitable to the generator. (b) Fuel Tank The fuel tank shall be mild steel suitable to hold fuel for not less than 12 hour’s running capacity and shall be including fuel level indicator, fuel line from tank to the engine etc. complete all as specified. (c) Alternator The alternator should be designed for an output of 200 KVA continuous rating at 0.80 PF as per IS: 13364 RPM, 1500 including self existing and self regulating control panel with accessories, brushless design, electric supply terminal box with gland earth terminals etc. complete all as specified. (d) Mounting arrangement Engine and alternator shall be mounted on common MS fabricated frame with anti vibration mounting pads.
CHHABINDRA KUMAR PRADHAN
M/S N C BANERJEE AND SON
MS SHRI B.C. DAS
FRIENDS CONSTRUCTION
CMRGS Infrastructure Projects Ltd
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .