Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹13.0 LAccepted-AOC | L-1 | Accepted-AOC Being L-1 | |
| 2 | L-1₹22.3 LRejected-Finance 0 GHULAM MOHAMMAD AND CO 0 GURUDAWARA II RAWALPORA SRINAGAR JAMMU AND KASHMIR RAWALPORA SRINAGAR JAMMU KASHMIR 190001 | SRINAGAR | JAMMU AND KASHMIR | 190001 | L-1 | Rejected-Finance Other than L-1 | |
| 3 | L-2₹14.8 LRejected-Finance | L-2 | Rejected-Finance Other than L-1 | |
| 4 | L-3₹16.6 LRejected-Finance | L-3 | Rejected-Finance Other than L-1 | |
| 5 | L-4₹18.1 LRejected-Finance DHARAM SALA SINGHAN CHADOORA DISTT BUDGAM J K | CHADOORA | BUDGAM | JAMMU AND KASHMIR | L-4 | Rejected-Finance Other than L-1 |
Tender Value
₹26.8 L
EMD Value
₹53,600
Closing Date
26 Feb 2024, 6:00 pmClosed
Lt. Col Preetham P GE
GE 970 EWS C/o 56 APO PIN-913970
REPAIR AND MAINT OF INTERNAL WIRING, BLDG SECURITY LIGHT,LIGHTENING CONDUCTOR AT MANASBAL AND BLDG SECURITY LIGHT,LIGHTENING CONDUCTOR, SUMMER, WINTER APPLIANCES, HEATING PLANT AT MANASBAL AND SONAMARG INCL HAWS UNDER GE 970 EWS
2024_MES_639401_1
GE 970 EWS-62/2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
MANASBAL AND SONAMARG INCL HAWS
AS PER TENDER
7 documents required · 7 mandatory
₹500
GE 970 EWS
₹53,600
Yes
24 Apr 2024
27 Jan 2024
2 Mar 2024
27 Jan 2024
26 Feb 2024
12 Feb 2024
Amount
Taking down carefully any type of copper/aluminium point wiring (light, fan, socket or power) complete including conduits/casing caping with fittings such as switches, ceiling roses, pendents, regulators, bells, sockets, fan regulator etc, removing the materials/debris and making good the disturbed surface of walls & floors etc to match with the original existing finish complete all as specified and as directed
M & L for one point wiring with PVC insulated un-sheathed cable with stranded copper conductor FR-LS conforming to IS : 694 of size 1.5 Sq mm single core, including one No. 1.5 Sq mm single core PVC insulated un-sheathed copper cable FR-LS as continuous earth wire drawn in and including PVC concealed conduit (ISI marked) medium grade white colour not less than 20 mm dia as per ground requirement with all accessories of same grade fixed on wall/ceiling including terminated in to Cast iron/pressed steel terminal box of required size made out of 2mm thick MS sheet duly painted both sides or PVC box ISI marked with 3 mm thick plastic laminated sheet top cover fixed with brass screw & cup washers for mounting switches, fan regulators etc for one light/fan/exhaust fan point controlled by one 5 Amp switch one way complete all as specified and as directed
Description All as per item No 2 here in before, but for one 3/5 Pin, 5 Amp socket out let on the independent board complete all as specified and as directed
Description All as per item No 2 here in before, but for one 3/5 Pin, 5 Amp socket out let on the same board complete all as specified and as directed
Description All as per item No 2 here in before, but for one 3/5 Pin, 15 Amp socket out let on the independent board using 2.5 Sq mm single core copper cable, complete all as specified and as directed
Description all as item No 2 above but surface point wiring with PVC Casing & Caping double lock type of as required width (not less than 20 mm in width) , complete all as specified and as directed
Description All as per item No 6 here in before, but for one 3/5 Pin, 5 Amp socket out let on the independent board complete all as specified and as directed
Description All as per item No 6 here in before, but for one 3/5 Pin, 5 Amp socket out let on the same board complete all as specified and as directed
Description All as per item No 6 here in before, but for one 3/5 Pin, 15 Amp socket out let on the independent board using 2.5 Sq mm single core copper cable, complete all as specified and as directed
Taking down unserviceable any type of copper/aluminium sub main wiring of any type/size/core/ type complete including conduits/casing caping etc, removing the materials/debris and making good the disturbed surfaces of walls, floors and ceilings etc to match with the original existing finish complete all as specified and as directed.
M & L for sub main wiring with two runs of single core 4.0 Sqm, FRLS Copper conductor PVC insulated unsheathed cable as per IS 694-1990 (third revision) drawn through & including non- metallic rigid PVC casing caping (double interlock type) of suitable width medium duty with all accessories such as Tees, elbows, junction boxes etc, as required fixed on wall along with one run of 4.0 Sqmm single core PVC FRLS insulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main switch board/ distribution board and testing on completion etc complete all as directed. (Note :- Two runs of main cable, one run of earth continuity conductor and one run of PVC casing caping/conduit shall be measred as one unit)
Description all as per item No 11 here in before, but two run of single core 6 sqmm and one run of 4 sqmm cables as earth continuity conductor all as directed.
Switch Piano flush button single pole one way 5 A , 240 V complete all as specified and as directed
Switch Piano flush button single pole one way 15 A , 240 V complete all as specified and as directed
Switch Socket Combination 5A/16A, 5 in 1, 3 pin, 240 volts complete all as specified and as directed
Switch Socket Combination 5A, 2 in 1, 3 pin, 240 volts complete all as specified and as directed
Socket outlet 2 in 1, 5 Amp flush type, 240 V, complete all as specified and as directed
Socket outlet 2 in 1, 5 & 15 Amp flush type, 240 V, complete all as specified and as directed
Ceiling rose, surface bakelite, 65 x 50 mm two/ three terminals 240 volts complete all as specified and as directed
Stepped type electronic fan regulator flush type as per exisitng model on the existing board all as directed.
S & F in repairs sheet metal enclosure SPN with a two pin and earth plug and socket complete with one SP MCB 20 Amps complete all as specified.
S & F in repairs MCB DB SPN 8 way, 230 Volt with 200 A rated bus bar double door type modular type complete all as specified and as directed.
Ditto all as per item No 15 here in before but MCB DB SPN 12 way DB 230 V with 200 A rated busbar.
S & F in repairs MCB TPN 63 amps 230 volts C curve, 50 HZ AC 10 KA complete all as specified.
S & F in repairs MCB SPN 63 amps 230 volts C curve, 50 HZ AC 10 KA complete all as specified.
S & F in repairs MCB SPN 40 amps 230 volts C curve, 50 HZ AC 10 KA complete all as specified.
S & F in repairs MCB SPN 32 amps 230 volts C curve, 50 HZ AC 10 KA complete all as specified.
S & F in repairs MCB SP 06 to 32 amps 230 volts C curve, 50 HZ AC 10 KA complete all as specified.
LED lamp 1 x 3/5/7 watts suitable for pin type batten/pandent holder complete all as directed.
Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and directed.
S & F in repairs Energy efficient surface Mounted LED Luminire 18/20 watts 4' long, with acrylic cover complete with all accessories incl necessary two core copper wire for connection from ceiling rose to connector of approx length 0.75 mtr all as directed. Make : - Bajaj Cat No BCLSB 18 WH /NW or equivalent in Philips/CG/Havells)
S & F in repairs Energy efficient surface Mounted LED Luminire 10 watts 2' long, with acrylic cover complete with all accessories incl necessary two core copper wire for connection from ceiling rose to connector of approx length 0.5 mtr all as directed. Make : - Bajaj Cat No BCLSB 10 WH / NW or equivalent in Philips/CG/Havella
Supply & fixing in repair square, 600x600mm, surface mounted LED Luminire 35/36 watts integral square shape surface mounting aluminium die cast edge lift panel complete with opal diffuser complete all as specified & directed.
Supply & fixing in repair round shape surface mounted LED Luminire 15 watts integral round shape recessed type with high efficieny PMMA diffuser soft glare free light with drivers complete all as specified & directed.
Supply & fixing in repair wall mounted LED light fitting of capacity 09 wattssuitable for B22 lamp base, including lamp made up of high grade engineering plastic material complete all as specified & directed.
M&L in repairs for Earthing complete with GI earth plate 60x60cmx6mm thick, burried directly in ground (Earth pit not less then 2.25 metres deep below ground level) with top edge of the plate not less then 1.5 metre below normal ground level, connected to galvanised earth lead wire 4.0 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron as earthing lead or steel all as shown in electrical plate No.3 and incl earth work, PCC (1:2:4) pit and 75mm th RCC (1:2:4) cover, watering pipe 20mm dia medium grade, funnel, wiremesh, charcoal dust, 15 mm dia light grade protection pipe and salt etc and connected to earthing test point incl necessary earth work complete all as specified and as directed.
M&L for opening the unserviceable/burnt ceiling fan 1200/1400 mm sweep and cutting of old burnt copper winding and rewinding the same with super enamelled copper winding wire of suitable gauge including insulating material such as paper cotton sleeves, varnish, reassembling, testing and connecting for satisfactory run, complete all as specified and directed (NOTE:- Taking down/dismantling of ceiling fan and refixing after repair shall deemed to be include in this unit rate.)
Supply and fixing in repair of ball bearing of the ceiling fan (any sweep) as per existing size incl greasing/oiling, complete all as specified and directed by engr-In-Charge. Make:- SKF/ NBC or Equivalent
Supply and fixing in repair of gun metal bushes of suitable size for ceiling fan incl necessary mechanical work, complete all as specified and directed by Engr-In-Charge.
Supply and fixing in repair of flexible cable, three core 0.5 Sqmm PVC insulated copper conductor cable for connecting ceiling fan, complete all as specified and directed. Make:- Plaza, Havells .
Supply and fixing in repair capacitor of of 2.5 MFD for ceiling fan, complete all as specified and directed.
Supply and fixing in repair capacitor of 4 Mfd for exhaust fan, complete all as specified and directed.
Supply and fixing in repair of ceiling fan blade set of three, heavy duty suitable for 1200/1400mm sweep of as per existing make as direcetd.
Supply and fixing in repair of PVC canopy for ceiling fan 1200/1400mm sweep complete for existing various makes/model of fan, complete all as specified and directed by Engr-in-Charge.
M&L in repair for opening and cutting of old burnt copper winding of exhaust fan and rewinding of exhaust fan motor of sweep 450mm with super enamelled copper winding wire of suitable gauge including insulating material such as paper cotton sleeves, varnish, re-assembling, testing and connecting for satisfactory run, complete all as specified and directed as specified and directed. (NOTE:- Taking down/dismantling of exhaust fan and refixing after repair shall deemed to be include in this unit rate.)
All as per srl item No. 45 here-in-before, but 300mm sweep.
Supply and fixing in repair ball bearing of exhaust fan of any size/make as per the existing, complete all as specified and directed. Make: SKF/NBC or equivalent .
M&L for painting the exhaust fan including louvers of size 300/450mm sweep with two coats of synthetic enamel paint after cleaning and making the surface of oil/dust free, complete all as specified and directed.
M&L for servicing of geyser by disconnecting the electric and water supply connections, dismantling the geysers of any size, type & capacity and opening the top and bottom cover, thermostat, heating element, safety valve, vent pipe, separating inner & outer tank, removing glass wool insulation complete and keeping aside for re-use after de-scaling of inner tank by liquid chemical and with pressure water jet and assembling back the geyser including re-installation on wall with studs, nuts & bolts complete and testing after reconnecting electric and water connections, complete all as specified and directed.
Supply and fixing in repair heating element for geyser of capacity 1.5KW, AC 230 Volts, 50 Hz (as per sample), complete all as specified and directed. Make:- Micron/ Bajaj/ Havells
Supply and fixing in repair Heating element for geyser of capacity 2.0KW, AC 230 Volts, 50 Hz (as per sample), complete all as specified and directed. Make:- Micron/ Bajaj/ Havells
Supply and fixing in repair thermostat for Geyser of capacity 25/35/50/100 ltr (long size) with temperature setting adjustment range from 40 to 85°C, ISI Marked, complete all as specified and directed. Make:- Philips/ Bajaj/ Venus
Supply and fixing in repair geyser syphon assembly Set suitable for 25 ltr capacity geyser, fixed in replacement, as per existing complete all as specified and directed by engr-in-Charge.
All as per item Srl No. 53 above but for 35 Ltr capacity.
All as per item Srl No. 53 above but for 50 Ltr capacity.
Supply and fixing in repair rubber gasket for water heater storage type of any capacity and suitable as per the existing, complete all as specified and directed
Supply and Fixing in repair plug top 15/16 Amps for Geyser, complete all as specified and directed. Make:- Havells/ Anchor/Leader/Plaza
Supply and fixing in repair PVC sheathed three core copper conductor flexible wire of size 2.5 Sqmm for connecting geyser, complete all as specified and directed. Make:- Finolex/Polycab/L&T
Supply and fixing in repair of safety valve for geyser of 25/35/50 litre capacity, as per existing make complete all as specified and directed
Supply and fixing in repair of non return valve 15mm dia for geyser of 25/50 litre capacity, complete all as specified and directed.
Supply and fixing in repair heavy duty PVC connector 600mm long 15mm dia with PTMT nut for geyser of 25/50 litre capacity, complete all as specified and directed.
Supply and fixing in repair copper inner tank of geyser capacity 15/25 litre and refilling of glass wool, refixing, connecting and testing, complete all as specified and directed.
All as per item Srl No. 62 above but for 35 Ltr capacity.
All as per item Srl No. 62 above but for 50 Ltr capacity.
Supply & fixing in repair stop cock brass 15mm dia, complete all as specified and directed.
Supply and fixing in repair of GI anchor Bolt 100 mm long with nut & washers for geyser, complete all as specified and directed
M&L for painting the geyser with two coats of synthetic enamel paint after cleaning and making the surface of oil/dust free, complete all as specified and directed.
Servicing and overhauling compressor of refrigerator of 165 to 200 ltr capacity as per the existing complete all as specified and directed.
Supply and fixing in repair of thermostat for refrigerator of 165 to 200 ltr capacity.
Supply and fixing in repair of thermal relay for refrigerator of 165 to 200 ltr capacity.
M&L for Charging refrigerant R134A and testing for proper cooling and leakage complete for refrigerator of 165 to 335 ltr capacity all as specified and directed.
M&L for disconnecting the electric supply from the mains, transporting the window/split type air conditioner capacity 1.5/2.0 ton from original location to workshop to carry out the servicing complete and re-fixing at the original position after repairs and making the ACs fully functional and testing for satisfactory working, complete all as specified and directed.
Taking out old burnt/unserviceable compressor from the air conditioner 1.5/2.0 ton capacity and supply and fixing new compressor as per the existing, re-fixing in position incl testing satisfactory working complete all as directed.
Supply and fix in repair blower motor suitable for 1.5/2.0 ton capacity air conditioner all as directed.
Supply and fix in repair thermostat suitable for 1.5/2.0 ton capacity air conditioner all as directed.
Supply and fix in repair of running condenser 36 Mfd, complete all as directed.
Supply and fix in repair of starting condenser 100/120 Mfd, complete all as directed.
Supply and fix in repair of relay suitable for 1.5/2.0 ton capacity air conditioner, complete all as directed.
Taking out unserviceable/burnt stabilizer of 3 KVA to 5 KVA capacity, rewinding the same with super enamelled copper winding wire of suitable gauge including insulating material such as paper cotton sleeves, varnish, reassembling, replacement of knobs, LED's etc. and making fully functional on load as connected to Refrigerator/Deep freezer/AC complete all directed.
All as per item Srl No. 79 above but for capacity 1 to 2 KVA .
Supply and fix repair sensor board suitable for water heater 25/ 35 Ltr capacity complete all as specified and directed. Make :- Venus/bajaj/Usha
Supply and fix LED bldg security light fitting 25/24 watts with high efficiency long life LEDs In-built replaceable electronic driver complete housed in pressure die-cast aluminium alloy covered with polycarbonate cover with IP65 degree of protection and fixing on existing bracket including taking down existing unserviceable street light fitting complete all as specified and directed.
Supply and fix LED street light fitting 36/35 watts with high efficiency long life LEDs In-built replaceable electronic driver complete housed in pressure die-cast aluminium alloy covered with polycarbonate cover with IP65 degree of protection and fixing on existing bracket including taking down existing unserviceable street light fitting complete all as specified and directed.
Description All as per item No. 83 here-in-before but of 60 watt ---ditto---
Description All as per item No. 83 here-in-before but of 45 watt ---ditto---
Supply and fixing in repair electronic driver with Input Voltage 220 to 240 Volt and Output Voltage suitable for LED Light Fitting of capacity 25 to 60 Watt, complete all as specified and as directed. Make: Philips/Havells/ Crompton Greaves/ Wipro/Bajaj/Surya
S & F in repairs Thermoplastic Cable Junction Box/Distribution Board size 295 x 295 x 100 mm, IP 65 with metric knockouts for cable entry of size 10 to 25 sq mm, 2 core including fastening clamp with LT pole, box hinged cover with locking arrangements including with terminals TPN busbar, with 01 No MCB SP 6A 'B' Serials complete all as specified and directed.
Supply and fixing in repair flexible PVC insulated, 3 core cable with stranded copper conductor wire of size 1.5 sqmm for street light complete all as specified and directed. Make: Finolex/ Polycab/ Havells
Excavation in trenches not exc 1.5 M wide and not exc 1.5 M in depth and getting out in soft/loose soil or hard/dense soil for taking up or laying of cable & electrical poles etc. complete all as specified and directed.
Returning, filling in including spreading, levelling, watering and well ramming in layers not exceeding 25 cms complete all as specified and directed.
Removing surplus soil to a distance not exc. 50m and depositing where directed at a level n. exc. 1.5m above the starting point complete all as specified and directed.
Supply and laying dry river sand to be laid in 8 cms before laying of cable and 15 cms above cable in trenche as cable cushioning and covering complete all as specified and directed. Note: for payment purpose punned thickness shall be measured
Supply and laying un-reinforced precast concrete cable cover of size 300mmx150mmx40mm, class LV, type 1, over sand cushioning to cable in trenches complete all as specified and directed.
Supply and laying, of XLPE under ground insulated, armoured,heavy duty LT 1100 volts 25 Sqmm 4 core grade cable with aluminium conductor ISI markedas per IS-70098 (Part-I), laid in trenches/pipes, fixed to poles/walls with suitable saddle & glands complete all as directed incl taking out the old burnt out cables all as specified and directed. NOTE - Excavation, earthwork, sand cushioning and brick protection shall be measured and paid separately under respective items.
Description all as per item No. 94 above but 16 Sqmm 4 core -ditto-
Description all as per item No. 94 above but 35 Sqmm 3.5 core -ditto-
Supply and fixing in repair of steel tubular poles complete with cast iron base plate, finial taper plug, bolts, nuts, screws as specified type 410 SP-31 (9.0 mtr long) and shifting of conductors and insulators etc incl painting the exposed portion of the pole with two coats of aluminium paint over a coat of red oxide primer and internally through out plus embedded portion with two coats of black bituminous paint over a coat of red oxide primer. Marking of pole number with black paint in yellow circle incl dismantling/ taking down of existing ploe complete all as specified and directed.
Material & labour for cement concrete 1:4:8 type D-2 (using 40mm graded stone aggregate) for foundation of pole complete all as specified and directed.
Material & labour for cement concrete 1:3:6 type C-1 (using 20mm graded stone aggregate) as in coping of pole complete all as specified and directed.
Material & labour for cement concrete 1:2:4 type B-1 (using 20mm graded stone aggregate) as in coping of pole complete all as specified and directed.
Supply and Fix in repair for street light fitting bracket made out of 32/40mm bore GI pipe, light grade, bend to shape, 1.2 metre long, fixed to pole/wall with and including two sets of clamps made out of flat iron of size 50 x 6 mm with bolts, nuts and washers, complete all connected accesories for fixing of GI bracket with pole including one coat of anti corrosive primer and two coats of aluminium paint, all as specified and directed.
Supply and fix in repairs galvanised iron tubes 50mm bore, light grade including all fittings fixed to wall, ceilings and or laid in floors/tenches/under road etc complete for cable protection all as specified and directed.
S&F moulded case circuit breaker four pole 100 Amps, 16 KA capacity 415V 50Hz with adjustable thermal and fixed magnetic relay incl taking out the old unserviceable complete all as specified and directed.
S&F residual current circuit breaker double pole 40 Amps, 30 mA capacity 415V, 50Hz with adjustable thermal and fixed magnetic relay incl taking out the old unserviceable complete all as specified and directed.
S&F residual current circuit breaker double pole 63 Amps, 30 mA capacity 415V, 50Hz with adjustable thermal and fixed magnetic relay incl taking out the old unserviceable complete all as specified and directed.
Supply and Fix in repair off load change over switch in sheet metal enclosure of capacity 100 Amps, FP, 415 V complete all as specified and directed.
Supply and fix LED flood light fitting of 150 Watts with driver inside a pressure die cast aluminium housing with toughened front glass cover, IP65 degree of protection includig taking down of existig unserviceable flood light fitting of any description complete all as specified and directed. Make: Bajaj Cat No. BJFL 150W LED I or latest upgraded equivalent model in Havells/ Wipro/Crompton Greaves
All as per Ser Item No. 107 here-in-before but of 240 Watts ---ditto--- Make: Bajaj Cat No. BJFL 200W LED I or latest upgraded equivalent model in Havells/ Wipro/Crompton Greaves
Supply and fix LED post top light fitting made in cast aluminium with decorative opal polycarbonate diffuser with IP 65 protection 20 watts with high efficiency long life LEDs In-built replaceable electronic driver complete fixing on existing bracket including taking down existing unserviceable street light fitting complete all as specified and directed.. Make: Bajaj Cat No. BGCL 40W LED WH or latest upgraded equivalent model in Havells/ Wipro/Crompton Greaves
Supply and fix LED landscape light fitting aesthetically designed with symmetrical light distribution with IP 65 protection 8/9 watts with all accessories including taking down existing unserviceable street light fitting complete all as specified and directed.. Make: Havells Cat No. CONEBLS8WLED830PSYMTOPC or latest upgraded equivalent model in Bajaj/ Wipro/Crompton Greaves
Supply and fix LED landscape light fitting aesthetically designed with symmetrical light distribution with IP 65 protection 16 watts with all accessories including taking down existing unserviceable street light fitting complete all as specified and directed.. Make: Havells Cat No. MUSHROOMBL16WLED730SSYMTOPC or latest upgraded equivalent model in Bajaj/ Wipro/Crompton Greaves
M&L painting of steel tubular pole 9.0 mtr long, by applying one coat of alluminium paint after scraping / brushing and cleaning the rust on pole and cross arms . Alluminium painting will be done on pole above 1.5 Mtr hight from ground level and balance 1.5 mtr from ground level will be painted by alternate layer of black and white enammelled paint ( 30 cms each) Pole Nos will be written on pole by black paint in yellow circle of 150mm dia complete all as specified and directed.
Supply and fixing in repair air termination rod, single pointed, copper rod 12mm dia and 30mm long complete all as specified and directed.
Supply and fixing in repair aluminium strip 25x3mm with saddles and fixing screws for roof conductors and down conductors above ground complete all as specified and directed.
Supply and fixing in repair copper strip 25x3mm with saddles and fixing screws for roof conductors and down conductors above ground complete all as specified and directed.
M&L for mild steel work as in clamp incl suitable nut, bolt, washer complete all as specified and directed.
M/S Noor Mohammad Shalla
M/s Bilal Construction
M/s Jaipal Associates
M/S MIR SAJAD ENTERPRISES
M/S B A Traders
M/S GHULAM MOHAMMAD AND CO.
M/S BHAT ENGINEERING WORKS
M/S A Q ENTERPRISES
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .