| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.6 LAccepted-AOC | L1 | Accepted-AOC being L1 | |
| 2 | L2₹10.0 L+₹59,790 (6.33%)Rejected-Finance | L2 | Rejected-Finance being L2 | |
| 3 | L3₹11.3 L+₹1.8 L (19.5%)Rejected-Finance | L3 | Rejected-Finance being L3 | |
| 4 | L4₹11.7 L+₹2.3 L (24.1%)Rejected-Finance | L4 | Rejected-Finance being L4 | |
| 5 | L5₹14.4 L+₹5.0 L (52.6%)Rejected-Finance | L5 | Rejected-Finance being L5 |
Tender Value
Refer Docs
EMD Value
₹45,300
Closing Date
14 Apr 2021, 6:00 pmClosed
GE WEST HISAR
GE WEST HISAR, HISAR MIL STN, HISAR 125006
REWIRING OF CERTAIN BLDGS AND DAY TO DAY MAINT AT ZONE B AT HISAR MIL STN UNDER GE(WEST) HISAR
2021_MES_431109_1
GE(W)HSR-77/20-21
Open Tender
Civil Works
Item Rate
330 days
HISAR MILITARY STATION
please refer tender documents
8 documents required · 8 mandatory
₹500
Yes
GE WEST HISAR
₹45,300
Yes
3 May 2021
16 Mar 2021
16 Apr 2021
16 Mar 2021
14 Apr 2021
31 Mar 2021
Amount
Taking down carefully copper/aluminum point wiring (light/fan/socket or power) complete including taking out existing unserviceable terminal boxes & conduit with switches/sockets/fan regulators and fittings such as ceiling rose, pendants, tube light fittings, lamp holders, brackets light fittings, rectangular blocks etc. and making good disturbed surface of walls, floors etc. to match with the existing surface etc complete all as specified and directed.
Taking down carefully copper/aluminium submain wiring from battan /conduit from DBs, MCBs etc and making good to distrubed surfaces of walls, floor etc complete all as specified and directed
M&L for point wiring for one light / bell point controlled by one switch with 1.5 sq mm, single core ,PVC insulated but unsheathed, FRLS cable, 1100 volts grade IS -694 marked, with multistandard copper conductors and earth continuity wire with similar 1.5 Sq mm cable (incl connecting to earth dolly) drawn through in existing concealed conduit concealed type in walls/ceilings and also incl chnage of new sunk type pressed steel terminal box and 3 mm thick plastic laminated sheet top covers complete all as specified and directed. (Note :- Switches, sockets etc shall be measured and paid for separately under appropriate items of BoQ' ).
All as per item No. 3.00 above but for one 3 pin 5 Amp socket outlet on independent board controlled by one number one way switch on independent board.
All as per item No. 3.00 above but for one 3 Pin 5 Amp socket outlet on the same board controlled by one number one way switch on same board.
All as per item No 3.00 above but point wiring with 2.5 sq mm single core FRLS cables and earth continuity wire with 2.5 Sq mm single core cable for one 3 pin 15 Amps socket out let point controlled by one nos, one way switch on indep bd.
M&L for point wiring for one light / bell /fan/ext fan point controlled by one way switch with 1.5 sq mm, single core ,PVC insulated but unsheathed, FRLS cable, 1100 volts grade IS -694 marked, with multistandard copper conductors and earth continuity wire with similar 1.5 Sq mm cable (incl connecting to earth dolly) drawn through rigid PVC casing caping accessories in walls/ceilings and also incl change of new sunk type pressed steel terminal box and 3 mm thick plastic laminated sheet top covers complete all as specified and directed.
All as per item No. 7.00 above but for one 3 pin 5 Amp socket outlet on independent board controlled by one number one way switch on independent board.
All as per item No. 7.00 above but for one 3 Pin 5 Amp socket outlet on the same board controlled by one number one way switch on same board.
All as per item No 7.00 above but point wiring with 2.5 sq mm single core FRLS cables and earth continuity wire with 2.5 Sq mm single core cable for one 3 pin 15 Amps socket out let point controlled by one nos, one way switch on indep bd.
M&L for point wiring for one light / bell /fan/ext fan point controlled by one switch with 1.5 sq mm, single core ,PVC insulated but unsheathed, FRLS cable, 1100 volts grade IS -694 marked, with multistandard copper conductors and earth continuity wire with similar 1.5 Sq mm cable (incl connecting to earth dolly) drawn through and including rigid PVC conduit and conduit accessories / fittings, fixed / laid in concealed in walls and surface on ceilings(including cutting chases in wall) and also including sunk in type pressed steel terminal box and 3 mm thick plastic laminated sheet top covers complete all as specified and directed.
All as per item No. 11.00 above but for one 3 Pin 5 Amp socket outlet on the same board controlled by one number one way switch on same board.
All as per item No 11.00 above but point wiring with 2.5 sq mm single core FRLS cables and earth continuity wire with 1.5 Sq mm single core cable for one 3 pin 15 Amps socket out let point controlled by one nos, one way switch on indep bd.
S&F switch piano flush type, single pole, one way, 5/6 Amp, 230/240 Volts grade complete all as specified and directed.
S&F switch piano flush type, single pole, one way, 15/16 Amp, 230/240 Volts grade complete all as specified and directed.
S&F bell push flush type, 5/6 Amp 230/240 Volts complete all as specified and directed.
S&F flush type socket outlet multipurpose piano type 3 Pin 5/6 Amp (with 2/3 pin outlet also) 230 volts AC complete all as specified and directed.
S&F flush type socket outlet multipurpose 6 Pin 15/16 Amp (with 6 pin 5/6 Amp outlet also) 230 volts AC complete all as specified and directed.
S&F in repair bell electrical, AC, 230/250 Volts, single pole complete all as specified and directed.
S&F in repair ceiling rose surface bakelite, 3 terminals with back plate etc complete all as specified and directed.
S&F in repair sheet metal enclosure distribution board TPN, 4 way, double door, powder coated, protection class IP-42, suitable for mounting MCB, DBs with min 200 Amp rating copper bus bar, complete all as specified & directed.
S&F in repair sheet metal enclosure distribution board SPN, 8 way, double door, powder coated, protection class IP-42, suitable for mounting MCB, DBs with min 200 Amp rating copper bus bar, complete all as specified & directed.
S&F in repair sheet metal enclosure distribution board SPN, 4 way, double door, powder coated, protection class IP-42, suitable for mounting MCB, DBs with min 200 Amp rating copper bus bar, complete all as specified & directed.
S&F MCB TPN, 63 Amps 240 Volts , type 'B' series, 10 KA, fixing in DB complete all as specified and directed.
S&F MCB SPN, 32 Amps 240 Volts , type 'B' series, 10 KA, fixing in DB complete all as specified and directed.
S&F MCB SP, 6 to 32 Amps 240 Volts , type 'B' series, 10 KA, fixing in DB complete all as specified and directed.
S&F sub main wiring with two single core cable PVC insulated unsheathed of copper multi stranded conductor FRLS cable of size 6 sqmm, 1100 votls grade drawing through and including suitable size rigid PVC conduit and fittings/accessories all fixed to concealed in walls/ceiling 6 sqmm unsheathed multistranded FRLS copper conductor cable for earth continuity and connected to common earth dolly including cutting chasing of wall, if required and making good disturbed surface in CM (1:3) and finishig the surface to match with existing surface, etc complete all as specified and directed. (Note:- Two lengths of 6 Sqmm cable, one length of 6 Sqmm cable will be measured as one length).
S&F Sub main wiring with two single core cable PVC insulated unsheathed of copper multi stranded conductor FRLS cable of size 6 sqmm, 1100 votls grade drawing through and including PVC casing caping medium duty and PVC insulated 6 sqmm unsheathed multistranded FRLS copper conductor cable for earth continuity and connected to common earth dolly complete all as specified and directed. (Note:- Two lengths of 6 Sqmm cable, one length of 6 Sqmm cable and one length of PVC casing caping will be measured as one length)
S&F Sub main wiring with two single core cable PVC insulated unsheathed of copper multi stranded conductor FRLS cable of size 4 sqmm, 1100 votls grade drawing through and including PVC casing caping medium duty and PVC insulated 4 sqmm unsheathed multistranded FRLS copper conductor cable for earth continuity and connected to common earth dolly complete all as specified and directed. (Note:- Two lengths of 4 Sqmm cable, one length of 4 Sqmm cable and one length of PVC casing caping will be measured as one length)
S&F in replacement LED Batten CRCA sheet box type fixture 4 feet,long Single Side Connection suitable for 18/20w Led tube light Rod with G13 lamp holders. Complete with Mounting Brackets & accessories as required with connections.
S&F in replacement LED tube rod only having aluminium extrusion 18W, 4ft for existing tubelight fitting all as specified and directed.
S&F in replacement of wall mounted decorative luminaire suitable for 1 x 8/9W LED B22 cap incl 1x8/9W LED bulb complete all as specified and directed.
S&F lamp holder insulated body with back plate suitable for batten fittings complete all as specified and directed.
S&F Ceiling fan regulator electronic step type of suitable wattage, 230V suitable for 1200/1400 mm ceiling fan etc complete all as specified and directed.
S&F in repair sheet metal enclosures with socket plug top and MCBs single pole and neutral enclosure with a 2 pin and earth plug and socket complete with one single pole MCB of 20 Amp rating 240 volts complete all as specified and directed.
S&F in replacement LED street light luminaries of cap 20 watt, SPD internal with lense, 240 volt, ,pressure dia cast aluminium housing frame, heat resistant toughtened clear glass with frame complete with accessories , IP 66 protection, pre wired up to a terminal block and mounting attachment,including pvc connector for connection complete all as specified
S&F in replacement LED light fittings 36 watt recess Mounting, 2"x2" Sheet aluminium housing with high quality LGP and PMMA diffuser. Separate HPF driver 240 volt along with fixing arrangements complete all as specified and directed.
Attending of complaints pertaining to faulty/Non-functional/working state of all accessories pertain to internal Electrification / through telephone or in person round the clock on detailment by MES Service centre for Offrs/JCOs/ORs Md/OTM Accn of Hisar Mil Stn by deploying electrician and locating and rectifying the fault from Elect Meter/DB onwards in respect of Sub Main /Point wiring including fixtures for power and light, socket, fan, bell point including security light fitted in bldgs etc complete and carrying out repairs to the extent of disconnection and dismantling of faulty wires, battens, conduits, boxes, Main switches, MCB, DBs, and other E/M faults pertaining to particulars equipment including providing wire upto 2.00 mtr and insulatiion tape required for the rectification of defect and refixing of existing dismantling serviceable articles complete all as specified and directed
Note :- (i) Scope of work shall include replacement of bulbs /tubes/ switches/socket/regulator/bell /MCB/ sheet metal enclouser/holder etc shall be measured and paid separately as " Supply only ". Old fitting fixtures held by users which will be handed over the repairer if so required. (ii) Complaint pertaining to location and rectification of fault in more than one wiring point/sub main wiring/DB etc shall be considered as one complaint. Similarly complaint pertaining to replacement of minimum three fixtures in one BK/qtr/office/bldg involving movement of electricians will also be measured and paid as one complaint. Replacement of more than three fixtures but multiple of four fixtures or part thereof in one Bk/qtr/office/bldg etc will be measured as additional complaint. (iii) The complaint slip/job card shall be prepared round the clock by the MES Staff/ Supervisor and shall be handed over to contractor’s tradesmen. Complaint slip shall be got singed by user with name, number and rank and return the same to MES staff by same day. Complaints of emergent nature e.g no light, short circuiting and earth fault etc. shall be attended, round the clock. Other complaints can be attended during normal working hours.In case complaint has not been attended with in stipulated time frame as per its priority class, suitable recovery on this account shall be made on the rates as specified here-in-after.
(iv) Bldgs requiring major nature of work e.g rewiring of complete bldg or major portion shall be intimated to JE E/M and separate team shall be deployed for the work. (v) Bldgs requiring rewiring of small qty of point wiring if ordered will be measured and paid separately. (vi) Cost of work requiring replacement of other stores will be measured as supply only and paid separately. (vii) Contractor shall provide the complain slip and containing 100 pages in triplicate properly binded and complaint book as per sample on requirement basis complete all as specified and directed. (viii) All stores will be deposited to MES stores and the same will be issued by MES staff to contract labours for day by day maint. (ix) Contractor shall provide the complain slip containing 100 pages in triplicate of size 5 inch x 8 inch property binded and printed with their farm name and tele phone numbers as per sample and directed by Engineer-inc-Charge.
Supply only type socket outlet multipurpose 6 Pin 15/16 Amp (with 6 pin outlet also) 230 volts AC complete all as specified and directed.
Supply only MCB TPN, 63 Amps , 415 Volts , type 'B' series, 10 KA, fixing in DB complete all as specified and directed.
Supply only MCB SPN, 20-32 Amps 415 Volts , type 'B' series, 10 KA, fixing in DB complete all as specified and directed.
Supply only MCB SP, 6 to 32 Amps 415 Volts , type 'B' series, 10 KA, fixing in DB complete all as specified and directed.
Supply only sheet laminated 3 mm thick including cutting required size drilling holes for incorporating switch, socket, regulators etc. complete all as specified and directed..
Supply only of capacitor 2.5 to 3.15 mfd as per existing capacity of 240V A.C complete all as specified and directed.
Supply only switch piano flush type, single pole, one way, 5/6 Amp, 230 Volts grade complete all as specified and directed.
Supply only bell push flush type 5 amps complete all as specified and directed.
Supply only piano type switch 15 Amps, single pole one way flush typecomplete all as specified and directed.
Supply only socket outlet 2/3 Pin 5 Amps Multi purpose Piano type, flush type complete all as specified and directed. .
S&F plug top 15 Amps, single pole, AC, 230 Volts, flush type complete all as specified and directed.
Supply only ceiling rose surface bakelite, 3 terminals with back plate etc complete all as specified and directed.
Supply only lamp holder insulated body with back plate suitable for batten fittings complete all as specified and directed.
Supply only fan regulator electronic dimmers,450w,250v flush type suitable for 1200/1400mm sweep ceiling fans complete all as specified and directed.
Supply only fan regulator Electronic step type suitable for 48/56” ceiling fan complete all as specified and directed.
Supply only in replacement LED tube rod only 18W, 4ft suitable for existing tube light fitting all as specified and directed.
Supply only in replacement LED tube rod only 20W, 4ft suitable for existing tube light fitting all as specified and directed.
Supply only PVC casing and caping, 15mm width complete all as specified and directed.
Supply only PVC casing and caping, 20mm width complete all as specified and directed.
Supply only P.V.C cable flexible 3 core 23/.0076, copper conductor complete all as specified and directed.
Material and labour for earthing complete with galvanized steel earth plate electrode 60cmx60cmx6mm thick burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of plate not less than 1.5 m deep below normal ground level and connected to and including galvanized iron earth wire 4 mm dia by means of GI nuts, bolts, check nuts, washers thimbles, etc as shown in electrical plate No 3 of SSR Part-I and connection to main switch board/Test point/panel/ equipment and testing on completion including excavation and earth work in any type of soil, returning filling in, and removal of surplus spoil to a distance not exc 50 metre, charcoal and salt in alternate layer 15 cm thick all around the earth plate electrode, MS funnel with wire mesh, GI pipe medium grade 20 mm bore for watering and 15 mm bore upto 7.50 metre long GI pipe light grade for earth wire protection fixed with poles/wall with two clamps, made from MS flat 25 mmx3mm, bolts, nuts and washers, PCC chamber (1:3:6) type C1, 40mm thick precast RCC cover 1:2:4 type B1 shall be provided on CI frame etc complete all as specified & as directed including dismantling & taking out old existing unserviceable earthing.
S&F in replacement LED light fitting complete 1x9W , (2Ft long) poly carbonate batten including LED Tube, complete all as specified and directed.
Supply only 1100 volts grade heavy duty cable PVC insulated aluminium stranded/Solid conductor, served with inner sheathing of PVC sheathed wire, one twin core cable flat or circular of 6sqmm complete all as specified and directed.
Supply only 1100 volts grade heavy duty cable PVC insulated aluminium stranded/Solid conductor, served with inner sheathing of PVC sheathed wire, one twin core cable flat or circular of 10sqmm complete all as specified and directed.
Taking down carefully unserviceable medium way light from the roof of capacity 250 watt at (1 CZWs) and making necessary reapir and prefixing again original position with all necessary minar connected item complete all as specified and directed.
Supply only in repair / replacement 250 watt ballast suitable for medium way light complete all as specified and directed.
Supply only in repair / replacement 250 watt metal halide lamp elliptical type suitable for medium way light complete all as specified and directed.
Supply only in repair / replacement Electronic igniter 250 watt suitable for medium way light complete all as specified and directed.
M/s Rao Constructions, 1173 Urban Estate-II, Hisar
M/S KAVITA CONSTRUCTION
YASHU CONTRACTORS
LACHHMAN SINGH AND BROTHERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .