Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.2 LAccepted-AOC | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹5.7 L+₹49,229.50 (9.53%)Rejected-AOC | L2 | Rejected-AOC Other than lowest bidder | |
| 3 | L3₹5.9 L+₹69,756.50 (13.5%)Rejected-AOC NO 3 JANI JAN KHAN ROAD 1ST LANE ROYAPETTAH CHENNAI 600 014 | CHENNAI | CHENNAI | TAMIL NADU | 600014 | L3 | Rejected-AOC Other than lowest bidder |
Tender Value
₹5.9 L
EMD Value
₹11,800
Closing Date
12 Mar 2021, 6:00 pmClosed
AGE(I) NAVY CHENNAI
AGE(I) Navy Chennai Military Engineer Services Fort St George Rajaji Salai Chennai 600 009
PROVISION OF EXHAUST SYSTEM AT SHIPS GALLERY, CEILING FANS AGAINST BER CEILING FANS, WATER COOLER WITH PURIFICATION SYSTEM (RO UV) AT VARIOUS NAVAL UNITS IN CHENNAI UNDER AGE(I) NAVY CHENNAI
2021_MES_421820_1
AGE(I)/NAVY/CHN/8186 of 2020 - 21
Open Tender
Electrical and Maintenance Works
Item Rate
120 days
CHENNAI
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
AGE(I) Navy Chennai
₹11,800
Yes
3 May 2021
12 Feb 2021
13 Mar 2021
12 Feb 2021
12 Mar 2021
26 Feb 2021
13 Feb 2021 - 19 Feb 2021
Amount
Taking down old unserviceable copper/aluminium point wiring (light,fan, socket or power) including old unserviceable fixture and fittings complete etc removing the materials for taking credit and making good the disturbed surface of wall/floor etc. complete all as specified and directed by Engineer in Charge.
Point wiring with 1.5 sqmm (Nominal area) unsheathed multi-stranded copper conductor PVC insulated cable 1100 volts grade single core drawn into and including non-metallic rigid PVC conduit of 20 mm dia/ PVC Casing capping along with 1.5 sqmm unsheathed multi stranded copper conductor cable PVC insulated 1100 volts grade as earth continuity conductor connected to common earth dolly fixed to wall/ ceiling roof with and including 2 mm thick MS sheet fabricated terminal boxes flush mounted for mounting the switches, sockets, fan regulator etc as required with 3mm thick laminated hylum sheet top cover all as specified and directed for one 3 pin socket outlet 5 amps socket on independent board
All as per item No. 2 here-in-before but with 2.5 sqmm cable for one 3 pin socket outlet 15 Amps on independent board with 2.5 sqmm cable as earthing conductor complete all as specified and directed by Engineer in Charge.
S&F in repair Modular switch 1 way 5A, 1 Module including taking down old unserviceable switch and removing the material for taking credit complete all as specified and directed by Engineer in Charge.
S&F in repair Modular switch 1 way 16A, 1 Module including taking down old unserviceable switch and removing the material for taking credit complete all as specified and directed by Engineer in Charge.
S&F in repair Modular Socket 5A-2/3 pin combined 2 Module including taking down old unserviceable socket and removing the material for taking credit complete all as specified and directed by Engineer in Charge.
S&F in repair Modular Socket 5A / 15A - 2 / 3 pin combined 2 Module including taking down old unserviceable socket and removing the material for taking credit complete all as specified and directed by Engineer in Charge.
S&F Modular White cover plate with frame, 3 Module including taking down old unserviceable modular cover plate and removing the material for taking credit complete all as specified and directed by Engineer in Charge.
S&F Modular metal flush box 3 module including taking down old unserviceable metal box removing the material for taking credit and making good the disturbed surface of wall complete all as specified and directed by Engineer in Charge.
Taking down carefully old unserviceable submain wiring with aluminum conductor cable 4/6/10/16 Sqmm in PVC conduit complete removing the materials and taken as credit and making good the disturbed surface of wall / floor etc. complete all as specified and directed by Engineer in Charge.
M&L for sub main wiring/ with four runs single core 16 sqmm multi stranded copper conductor PVC insulated unsheathed cable 1100 volts grade and one run of 16 sqmm multi stranded copper conductor cable as earth continuity conductor drawn into and including non-metallic rigid PVC conduit 40 mm dia/PVC casing capping 32 mm including conduit accessories complete all as specified and directed by Engineer in Charge. Note: Five runs of 16 Sqmm cable and one run of 40 mm conduit / casing capping will be measured as one unit length.
M&L for wiring for circuit of size 2 x 4.0 sq.mm along with earth wire of size 1 x 4 sq.mm, Single Core, PVC insulated copper coductor (FRLS) Cable in surface / recessed PVC Conduit complete all as specified and directed by Engineer in Charge.
S&F sheet metal enclosure powder coated double door for distribution board, VTPN 4 way DB including, disconnecting electric connections, dismantling from position unserviceable DBs for taking into credit complete all as specified and directed by Engineer in Charge.
S&F MCB SP 5 A to 32 A , B curve including , Disconnecting electric connections, dismantling from position unserviceable MCB for taking into credit complete all as specified and directed by Engineer in Charge.
S&F MCB TP 50A / 63 A , C curve including , Disconnecting electric connections, dismantling from position unserviceable MCB for taking into credit complete all as specified and directed by Engineer in Charge.
Supply & Replace for Isolatar Four Pole, 50 A/ 63A including , disconnecting electric connections, dismantling from position unserviceable Isolator for taking into credit complete all as specified and directed by Engineer in Charge.
Fabrication Supply and installation of 3 HP kitchen centrifugal blower unit with following specification complete all as specified and directed by Engineer in Charge. (a) Motor 3HP/1440 RPM/ 3 Phase(body made up of MS) (b) Provison of ducts of size 525 x 345 mm and length 2000mm to meet the requirements (c) GI Oil filter of required size -6 Nos (d) DOL starter 3HP with proper wiring for connection on required basis
S&F Ceiling fan 1200 mm or 48” sweep BLDC motor complete all as specified and directed by Engineer in Charge. Make Orient Model: Atomiser or equivalent in Usha/Bajaj/Crompton
S&F Stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc complete all as specified and directed by Engineer in Charge.
S&F and testing of water cooler with inbuilt RO purifier of storage capacity 80 ltrs and capacity of 40 ltrs/hr single phase power supply ensuring IS 10500:2012 standard for drinking water complete all as specified and directed by Engineer in Charge. Makes: Voltas/ Bluestar
S&F voltage stabilizer for automatic operation,single phase naturally air cooled indoor type and desigend for input variation between 135 V to 280 V with output voltage stabilized at 230 V and of capacity 1.0 KVA complete all as specified and directed by Engineer in Charge. Make : V-guard Model VG 100 or equivalent as approved
M&L for Point wiring with 4 sqmm (Nominal area) unsheathed multi-stranded copper conductor PVC insulated cable 1100 volts grade single core for one 3 pin socket outlet 15 Amps on independent board drawn into and including non-metallic rigid PVC conduit of 20 mm dia/ PVC Casing capping along with 4 sqmm unsheathed multi stranded copper conductor cable PVC insulated 1100 volts grade as earth continuity conductor connected to common earth dolly fixed to wall/ ceiling roof with and including 2 mm thick MS sheet fabricated terminal boxes flush mounted for mounting the switches, sockets, fan regulator etc as required with 3mm thick laminated hylum sheet top cover all as specified and directed
S&F Switch socket outlet multipurpose 3 pin, 15 amp and one pin, 5 amp modular type controlled by one switch complete all as specified and directed by Engineer in Charge.
S&F MCB SP 25 A, B curve complete all as specified and directed by Engineer in Charge.
S&F 20 mm bore Tubes, 'Medium grade' galvanised,with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and directed by Engineer in Charge.
S&F 15 mm bore Tubes, 'Medium grade' galvanised,with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and directed by Engineer in Charge.
S&F ISI mark 15mm bore Stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed by Engineer in Charge.
S&F ISI mark 20mm bore Stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed by Engineer in Charge.
M&L for providing, cement concrete 1:2:4 type B1 using 20 mm graded agregate as in roof kerbs or mud stops, rounded or chamfered on edges complete all as specified and directed by Engineer in Charge.
M&L for for 100 mm thick screed bed or bedding layer in CM 1:3 for laying floor finishes complete all as specified and directed by Engineer in Charge.
M&L for non skid coloured ceramic tiles 7 to 8mm thick (Square/ rectangular) area of each tiles exceeding .11 sqm but not exceeding .18 sqm in floors etc set and jointed in neat cement and pointed in white or coloured cement to match complete all as specified and directed by Engineer in Charge.
Green Ray Technologies
SRI LAKSHMI ASSOCIATES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .