RequiredExperience with Government
RequiredAnnual Turnover
RequiredCertificate (Requested in ATC)
RequiredOEM Authorization Certificate Bid to RA enabled No Pabx System-EPABX ( 2 set ) ( Under PAC ) Make nec Model necsv9100 Technical Specifications * As per GeM Category Specification Specification Specification Name Values Bid Requirement (Allowed Values) EXTENSION AND TRUNK/JUNCTION EPABX system Implementation Tech Hybrid ( Microprocessor based also supporting Hybrid ( Microprocessor based also supporting 1/12 nology/Architecture SIP extension ) SIP extension ) Number of Analogue Extensions/FXS Ports 0 24
Required48
Required64
Required96
Required128
Required160
Required192
Required224
Required256
Required320
Required384
Required448
Required576
Required704
Required832
Required960
Required1088
Required1600
Required2112
Required2624
Required3136
Required3648
Required4160
Required4672
Required0 Or higher Expandable Upto (TDM/FSX Ports) 1296 1296 Number of Digital Extensions 32 32 Number of Analogue Junction/FXO ports 16 16 Number of SIP Extensions 4 4 SIP Extensions expandable upto 512 512 Number of SIP Trunks NA NA MAIN DISTRIBUTION FRAME(MDF) MDF(Number of pair) 100 100 Integrated Protection Module(IPM) Yes Yes If YES
Requirednumber of Integrated Protection Module(IPMs) 50 50 CARDS CARDS Type of Cards Supported BRI
RequiredPRI
RequiredE&M BRI
RequiredPRI
RequiredE1
RequiredE&M
RequiredRadio Interface
RequiredGSM
RequiredNA Number of Ports per Card Supported 8 1
Required2
Required4
Required6
Required8
Required12
Required16
Required24
RequiredNA GATEWAYS Type of Gateways Supported Universal Gateway * Number of Ports per Gateway Supported 1 * CONSOLE Type of Operator Console Key phone based Key phone based Number of Operator Console 32 32 SERVER SPECIFICATIONS REQUIREMENTS Total Number of Servers Included in the Supply 1 * "Number of Hot Standby Servers out of Total Servers
Requiredincluded in the Scope of Supply" 0 * 2/12 Server Form Factor Rack * Rack Size (RU)/Space Required for each Server 2 * Processor Make NA * Processor Configuration & Description 32 bit Processor * Total Number of processor 1 1
Required2
Required4
Required6
Required8
Required10
Required12
RequiredNA Number of Redundant Processors Included in the Total Number of Processor NA 1
Required2
Required4
Required6
Required8
Required10
Required12
RequiredNA Number of Cores per Processor NA * Type of RAM DDR3 * RAM Size (in GB) NA 4
Required8
Required16
Required32
Required64
Required128
Required256
RequiredNA T ype of Hard Disk Drive NA * Capacity of Hard Disk Drive (in TB) NA NA Hot Swap Components NA NA Network Interface NA * SOFTWARES Applcation Software Type/Capabilities Call Server Software
RequiredUnified Communication Server Software Call Server Software
RequiredUnified Communication Server Software Type of Licence Perpetual Perpetual Name of Softwares SV 9100 system licenses * Name of the OEM NEC * OEM Model/Part Number SV 9100 * Software Description SV 9100 System Licenses * Software Version R9 * Date of Launch of Version 13.05.2019 * Free supports/updates during validity of license YES * SOFTWARE FEATURES Analog YES YES 3/12 Extention/FXS ( If Yes
RequiredNumber of Software/Licences shall be Commensurate Equal to the Number of Analog Extension/FXS Offered under ""EXTENSION AND TRUNK/JUNCTION"" ) "Digital Extension ( If Yes
RequiredNumber of Software/Licences shall be Commensurate Equal to the Number of Digital Extension Offered under ""EXTENSION AND TRUNK/JUNCTION"" )" YES YES "Analog Junction/FXO ( If Yes
RequiredNumber of Software Licences shall be Commensurate Equal to the Number of Analog Junction/FXO Offered under ""EXTENSION AND TRUNK JUNCTION"" )" YES YES "SIP extension ( If Yes
RequiredNumber of Software/Licences shall be Commensurate Equal to the Number of SIP Extension Offered under ""EXTENSION AND TRUNK/JUNCTION"" )" YES YES "SIP trunk ( If Yes
RequiredNumber of Software Licences shall be Commensurate Equal to the Number of Offered under ""EXTENSION AND TRUNK/JUNCTION"" )" YES YES 4/12 "PRI Trunk ( If Yes
RequiredNumber of Software Licences shall be Commensurate Equal to the Number of PRI Trunk Offered under ""EXTENSION AND TRUNK JUNCTION"" )" YES YES "Radio Interface ( If Yes
RequiredNumber of Software/Licences shall be Commensurate Equal to the Number of Radio Interface Offered under ""EXTENSION AND TRUNK/JUNCTION"" )" NA ( For Convensional PBX ) NA ( For Convensional PBX ) "GSM ( If Yes
RequiredNumber of Software Licences shall be Commensurate Equal to the Number of GSM Offered under ""EXTENSION AND TRUNK JUNCTION"" )" NA ( For Convensional PBX ) NA ( For Convensional PBX ) "E1 Trunk ( If Yes
RequiredNumber of Software Licences shall be Commensurate Equal to the Number of E1 Trunk Offered under ""EXTENSION AND TRUNK JUNCTION"" )" NA ( For Convensional PBX ) YES
RequiredNO
RequiredNA ( For Convensional PBX ) "E&M ( If Yes
RequiredNumber of Software Licences shall be Commensurate Equal to the Number of E&M Offered under ""EXTENSION AND TRUNK JUNCTION"" )" YES YES
RequiredNO GENERAL FEATURES of EPABX SYSTEM Number of Conference Participants Supported 32 32 Number of Direct Station Selection Keys per Console 24 * 5/12 Number of Media Channel/Ports Supported 256 256 Number of IP-TDM Concurrent Calls(2 users per call) Supported 256 256 Call Buffer Memory System Yes Yes If Call Buffer Memory Available
RequiredNumber of Records 2000 2000 Hot Standby Redundant CPU No Yes
RequiredNo If YES
RequiredNumber of Hot Standby CPU Cards NA 1
Required2
RequiredNA Hot Standby Redundant PSU (Power Supply Unit) No Yes
RequiredNo If YES
RequiredNumber of Hot Standby Redundant PSU Cards NA NA Inbuilt Voice Mail for EPABX System Yes Yes
RequiredNo If Voice Mail Available
RequiredNumber of Voice Mail Channels NA 4
Required8
Required16
Required32
Required64
RequiredNA Available for Voice Mail
RequiredNumber of Hours of Recording 4 4
Required8
Required16
Required32
Required64
Required128
Required256
Required512
RequiredNA Auto Attendant Facility Yes * If Available
RequiredNumber of Auto Attendant Channels 4 * ASMDR/CDR Yes Yes
RequiredNo Voice Logger Inbuilt External Connecting facility Inbuilt
RequiredInbuilt External Connecting facility
RequiredNA If YES
RequiredNumber of Simultaneous Calls that can be Recorded in Voice Logger NA * Security Feature(for server based) MD-5 * Supported Functionalities (for server based) NA * 6/12 Supported Codecs G711
RequiredG729
RequiredG723 * Any other features UC Ready
Requiredin-skin UC
Required4 Video MCU
RequiredCall-Center * SYSTEM/EXTENSION/AT TENDANT CONSOLE FEATURES System Features Automatic Route Selection facility
RequiredDID facility(Direct inward dialing)
RequiredDOD facility(Direct outward dialing)
RequiredDISA facility(Direct inward station access)
RequiredDOSA facility(Direct outwards station access)
RequiredMulti Level Voice DISA facility
RequiredPrivacy of Call
RequiredFacility for connecting recorded voice answering
RequiredASMD R/CDR
RequiredProgrammable class of service for (STD/ISD/LOCAL) dialing as per need
RequiredCaller ID information for both internal and external callers (over Analogue
RequiredISDN PRI)
Requiredunique authorization codes for every users
RequiredAutomatic call back
RequiredCall waiting
RequiredMusic-on-hold facility
RequiredCall budgeting
RequiredLeast cost routing
RequiredMix-mode dialing
RequiredProvision for remote logins
RequiredInteractive Voice Response System(IVRS)
RequiredExtensio n to Extension dialing * Extension Features Call forwarding
RequiredConsultatio n Hold
RequiredBrokers Call
RequiredAutomatic call transfer
RequiredConference call
RequiredCall pick up
RequiredCall re routing
RequiredAuto call disconnection
RequiredDynamic STD Lock
RequiredPaging on key phone
RequiredBackground music
RequiredPassword control
RequiredVirtual Telephony
RequiredHowler Tone
RequiredCall parking
RequiredAuto answer/Auto off
RequiredEmergency call facili * 7/12 ty
RequiredMissed/Dialed/Receiv ed Call Lists
RequiredLast Caller Call back
RequiredPassword display suppression
RequiredPersonal Identification Number
RequiredHotline
RequiredPreset Conference Calls
RequiredDirect Call billing in rupees
RequiredCall billing printout
RequiredCalling line ide ntification(CLI)
RequiredRemote Maintenance
RequiredOther Extension features Attendant Console Features Answering an incoming call
RequiredCall queuing
RequiredSerial Call
RequiredCall waiting display
RequiredAutomatic Call Distribution
RequiredCall Hold
RequiredTrunk offering
RequiredNight service
RequiredHead phone connectivity
RequiredOther Attendants console Features Answering an incoming call
RequiredCall queuing
RequiredSerial Call
RequiredCall waiting display
RequiredAutomatic Call Distribution
RequiredCall Hold
RequiredTrunk offering
RequiredNight service
RequiredHead phone connectivity
RequiredOther Attendants console Features Voice Prompts and Announcement Yes * If yes
RequiredNumber of Levels of IVRS 3 1
Required2
Required3
Required4
Required5
Required6
Required7
Required8
RequiredNA POWER SOURCE Supply Voltage 230V AC
Required50HZ 230V AC
Required50HZ Provision for Inbuilt Battery Charging Arrangement for providing Battery Backup YES * FCBC NA NO
RequiredNA If YES
Requiredminimum current Rating of FCBC at chrging voltage of 48V (Ampere) NA NA Protection against over current and accidental reversal of polarity on the input side and against over current
Requiredover voltage on the output side YES * OPERATING CONDITIONS Minimum Operating Temperature (Degree C) 0 0.0 Maximum Operating 45 45.0 8/12 Temperature (Degree C) Operating Humidity (RH) (% ) 95 95 TEST REPORT DETAILS AND TESTS TEC approval as per the latest TEC specifications YES * TEC approval Certificate number TEC/NR/I/PBX-004/03/1 38.JAN 19 * Availability of the test report from Central Government/NABL ILAC acredited lab to prove conformity to the specification including Environmental Test Sequence Yes * Test Report Number and date (not a part of biddable parameter) ENV/G-0166/0476/2018 Date: 31/03/2018 * Name and Address of the Test lab(not a part of biddable parameter) EQDC Lab Gandhinagar * Test reports consist of verification of all the features & functional parameters & environmental tests Yes * conformity to Dry Heat for 16 hours at maximum specified temperature degree C in accordance with IS:9000/part-3/sectio n-5/1977 latest Yes Yes conformity to Cold Test for 4 hours at minimum specified temperature degree C in accordance with IS:9000/part-2/sectio n-4/1977 latest Yes Yes conformity to Damp Heat (Cyclic)Test for 2 Cycles of 24 h each at a temperature of 40 degree C & 95% RH in accordance with IS:9000/part-5/s ection-1/1991 latest Yes Yes INSTALLATION AND MAINTENANCE Installation and Commissioning With With 9/12 Chemical Earthing to achieve resistance < 2ohm No Yes
RequiredNo Recommendation Information regarding Supporting Hardware Required to meet the Performance Capabilities of the System Dedicated Telecom Grade Earthing
RequiredStable Power * OPERATION & MAINTENANCE SUPPORT The scope of supply include one set of operation and maintenance manual for each equipment YES * Operation & Maintenance terminal Provided * Training provided to buyers Yes Yes If YES
RequiredDetails of training On site training for 3 days On site training for 3 days Packing List Main Cabinet
RequiredCPU
RequiredDigital Card
RequiredSLT Card
RequiredTrunk * SERVICES Warranty 1 1
Required2
Required3
Required4
Required5
Required6
Required7
Required8
Required9
Required10 Or higher Recommendation Information regarding Supporting Hardware Required to meet the Performance Capabilities of the System
RequiredDust Free Environment * Compliance to STC of the Product Yes * * Bold specifications are the golden parameters. * Bidders may note that In respect of non-golden Parameters
Requiredthe specifications 'Values' chosen by Buyer will generally be preferred over 'Bid requirement ( allowed Values) by the Buyer.