| 1.00Supply of following Decentralized materials at the works site as per RESSPO norms | ||||||
| 1.01 | Exctention Bracket with clamp and nut bolt | 40 | No | 2,100 ₹84,000 Lowest | 2,500 ₹1,00,000 | 2,100 ₹84,000 Lowest |
| 1.02 | Stone pad 300x300x75 mm | 64 | No | 250 ₹16,000 Lowest | 250 ₹16,000 Lowest | 400 ₹25,600 |
| 1.03 | X-arms holding clamps with bolts & nuts. | 37 | No | 350 ₹12,950 Lowest | 350 ₹12,950 Lowest | 400 ₹14,800 |
| 1.04 | F-bracket with bolts & nuts | 37 | No | 350 ₹12,950 Lowest | 350 ₹12,950 Lowest | 400 ₹14,800 |
| 1.05 | Al. binding wire | 6.5 | Kg | 195 ₹1,267.5 Lowest | 195 ₹1,267.5 Lowest | 550 ₹3,575 |
| 1.06 | M.S clamp for Top, T-off channel with bolts & nuts | 112 | No | 350 ₹39,200 Lowest | 350 ₹39,200 Lowest | 400 ₹44,800 |
| 1.07 | Guarding Angle Clamps | 44 | No | 350 ₹15,400 Lowest | 350 ₹15,400 Lowest | 400 ₹17,600 |
| 1.08 | P.G clamps for weasel conductor | 70 | No | 350 ₹24,500 Lowest | 350 ₹24,500 Lowest | 400 ₹28,000 |
| 1.09 | Danger board with clamp & bolts | 47 | No | 540 ₹25,380 | 540 ₹25,380 | 400 ₹18,800 Lowest |
Tender Value
₹1.5 Cr
EMD Value
₹1.5 L
Closing Date
18 Aug 2023, 1:00 pmClosed
SUPERINTENDING ENGINEER EDC Mirzapur
SUPERINTENDING ENGINEER EDC Mirzapur
System Strengthening Work under EDD-II, Mirzapur
2023_PVVNV_825554_1
42/EDC(M)/23-24
Open Tender
Electrical Works
Lump-sum
90 days
SUPERINTENDING ENGINEER EDC Mirzapur
Please refer tender
2 documents required · 2 mandatory
₹5,900
Executive Engineer(A)
₹1.5 L
SUPERINTENDING ENGINEER EDC Mirzapur
12 Oct 2023
1 Aug 2023
19 Aug 2023
1 Aug 2023
18 Aug 2023
1 Aug 2023
4 Aug 2023
Amount
Supply of following Decentralized materials at the works site as per RESSPO norms
Exctention Bracket with clamp and nut bolt
Stone pad 300x300x75 mm
X-arms holding clamps with bolts & nuts.
F-bracket with bolts & nuts
Al. binding wire
M.S clamp for Top, T-off channel with bolts & nuts
Guarding Angle Clamps
P.G clamps for weasel conductor
Danger board with clamp & bolts
Barbed wire GI
E-bracket with bolts & nuts
Dead end clamp for pole/bracket with nuts & bolts
I Hook ( for dead end Clamp)
Suspension clam with nuts & bolts
I Hook ( for suspension Clam)
M.S clamp with nuts bolts painted with redoxide
L.T connector A type
L.T connector B type
L.T bare nuetral connector
1x35 sq mm AC cable (XLPE)
Stay Clamp with clamp and nut bolt
All. Binding wire 6 mm
Safe Cartage of following all materials from ESC, Mirzapur to work Pits site including loading & unloading charge
10 MVA Transformer (Provided by Department)
33 KV VCB with single T/F control pannel and CT 200/100/1 A with structure (i) 33 KV VCB (ii) Control pannel I/C for 33 KV single T/F(iii) CT 200/100/1-1A (iv) Steel Structure (Provided by Department)
11 KV VCB O/G, 200/100/5A (Provided by Department)
11 KV VCB I/C, 600/300/5A (Provided by Department)
11 KV XLPE Cable size 3x300 mm2 for Above Sub-Station (Provided by Department)
11 KV XLPE Cable size 185 mm2 (Provided by Department)
11 KV XLPE Cable size 120 mm2 (Provided by Department)
Cable jointing Kit O/G, I/C (Provided by Department)
Control Cable size 4x2.5 mm2 (Provided by Department)
Control Cable size 2x2.5 mm2 (Provided by Department)
33 KV Bus Isolator (Provided by Department)
Structure for above (Provided by Department)
33 KV Post Insulator set (Provided by Department)
Structure for above (Provided by Department)
Transformer bus complete with structure (Provided by Department)
33 KV lightening arrestor (Provided by Department)
Structure for above (Provided by Department)
5 MVA Transformer (Provided by Department)
24 Volt Battery and Battery charger with Cabinet
90 lbs rail pieces (44.64 Kg/M) (Provided by Department)
33 KV Pin Insulator (Provided by Department)
33 KV Pin with nuts (Provided by Department)
ACSR Dog Conductor (Provided by Department)
ST Poles 11 mtr long (Provided by Department)
PCC Poles 8.5 mtr long (Provided by Department)
Line materials with ACSR Weasel Conductor (Provided by Department)
Arial Bunch Cable 3x120+95+1x16 mm2 (Provided by Department)
Arial Bunch Cable 3x195+1x70+1x16 mm2 (Provided by Department)
Distribution boxes/Kiosk for LT pole/bracket with clamp & nut bolt (Provided by Department)
11 KV Cross Arm (Provided by Department)
11 KV Pin Insulator with Pin (Provided by Department)
33 KV Pin Insulator (Provided by Department)
33 KV Pin (Provided by Department)
11 KV Disc Insulator with fitting (Provided by Department)
11 KV Stay Set Complite (Provided by Department)
Earhing Complite (Provided by Department)
T-off Channel (Provided by Department)
Top Channel (Provided by Department)
Base Angle (Provided by Department)
11 KV Dropper Channal (Provided by Department)
Cross Beacing MS Angle (Provided by Department)
Distribution Box LT (Provided by Department)
1x400 mm Sq PVC LT Cable (Provided by Department)
1x150 mm Sq PVC LT Cable (Provided by Department)
1x70 mm Sq PVC LT Cable (Provided by Department)
All Lugs (Provided by Department)
400 KVA T/F (Provided by Department)
250 KVA T/F (Provided by Department)
100 KVA T/F (Provided by Department)
63 KVA T/F(Provided by Department)
25 KVA T/F(Provided by Department)
Erection
Erection of single support ST/PCC pole for construction of 11 KV/LT line including digging of pit, fitting of all accessories, back filling of earth & others required work.
Grouting of pole with 1:4:8 ratio of cement sand & brick ballast as per RESSPO norms. (cement sand & brick ballast wil be supplied by the constractor on his own his own cost)
Grouting of stay sets including digging of pit with 1:4:8 ratio of cement sand & brick ballast as per RESSPO norms, fixing binding and nuzzling of stay wire. (cement sand & brick ballast wil be supplied by the constractor on his own his own cost)
Earthing of Poles
Stringing & sagging of 3 phase 11 KV line upto proper sag including laying of ACSR Weasel Conductor, binding with insulators & jumpering.
Erection of Sectional Double Pole Structure of ST pole including digging of pit, fitting of all accessories, back filling of earth, grouting of each pole & stay sets with materials & other required works.
Erection of Sectional Double PCC Pole Structure with the help of one pole already erected including digging of pit, fitting of all accessories, back filling of earth, grouting of each pole & stay sets with materials & other required works.
Construction of Transformer plinth for 250 KVA Transformer of 2x2x1.5 mtr. Including the work of excavation for foundation of plinth plastering of walls and finishing including cost of all materials.
Well type earthing of 250 KVA Transformer by using B class G.I. pipe of 1.5 " dia and making hand pipe type earth boring IInd strata of water or 60 ft. whichever is deeper about 6" of G.I. pipe shall remain above ground level 2 No. G.I. earth clamp shall also be welded to the portion of pipe which is above the ground level. Through this G.I. Clamp and G.I. Strip 30x5mm duly galvanized shall be connected with nut & bolts. Every DT shall have 2 such earthing, One earthing for T/F neutral and second earthing for T/F body. All requred materials shall by provided by the contractor.
Fencing of T/F with M.S. Square mesh welded/fixed on M.S. Angle of size 65x65x6 mm with gate hinges & shutter assembly, of over all size 3x3x2.5 mtr as per drawing
Mounting of 25 KVA Transformer as per RESSPO norms
Mounting of 63 KVA Transformer as per RESSPO norms
Mounting of 100 KVA Transformer as per RESSPO norms
Mounting of 250 KVA Transformer as per RESSPO norms
Mounting of 400 KVA Transformer as per RESSPO norms
Gaurding of 11 KV line as per RESSPO norms
Laying of 11 KV XLPE cable size 3x300/185 mm2 including cost of sand & bricks( duble ckt)
Laying of 11 KV XLPE cable size 3x120 mm2 Overhead ( duble ckt)
Filling of I/D/O/D 11 KV cable jointing kit size 3x300/185/120 mm2
Making of 11 cable box Mounted with switchgear and T/F
Installation of 5 MVA 33/11 KV Power Transformer as per RESSPO norms
Foundation of Pilth 5 MVA Transformer
Neautral 3 no Pipe 60 feet boring 1 delta Earthing of 5 MVA Transformer including cost of all materials GI Stripe 50X 6" size as per RESSPO norms
Installation of 10 MVA 33/11 KV Power Transformer as per RESSPO norms
Foundation of Pilth repair for 10 MVA Transformer
Neautral 3 no Pipe 60 feet boring 1 delta Earthing of 10 MVA Transformer including cost of all materials GI Stripe 50X 6" size. as per RESSPO norms
Installation of 11 KV VCB pannel (O/G), 200/100/5A
Installation of 11 KV VCB pannel (I/C), 600/300/5A
Installation of 33 KV VCB with single T/F control pannel and CT 200/100/1 A with structure (i) 33 KV VCB (ii) Control pannel I/C for 33 KV single T/F (iii) CT 200/100/1-1A (iv) Steel Structure
laying of Control Cable size 4x2.5 / 2x2.5 mm2 Trunch
Installation of 33 KV Bus Isolator
Installation of Structure for above
Installation of 33 KV Post Insulator
Installation of Structure for above
Installation of 33 KV lightening arrestor
Installation of Structure for above
Installation of Transformer fitting fixxing and Grouting of cable stand with all materials.
Testing & commissioning of I/C/O/G 11 KV swichgear
Testing & commissioning of 33 KV VCB with single T/F control pannel and CT 200/100/1 A
Construction of plinth & foundation of 11 KV VCB as per RESSPO norms
Painting of all equipments
Earthing for Outdoor structure such as Bus Isolator, Post Isolator set, Lighting Arrestor, Brecker & CT etc. through boring till the water level with G.I Pipe 40mm & G.I strip 50X6 '' and connect of all structure as per RESSPO norms
Earthing for Indoor structure including 11 KV VCB IC/OG pannel etc through boring till the water level with G.I Pipe 40mm & G.I strip 50X6 '' and connect of all VCB Pannel as per RESSPO norms
Fencing of Switchyard with gate etc through Barbed wire as per RESSPO norms
safe Cartage of old received back 5 MVA Transformer from work site to ESC, Mirzapur including loading & unloading charge
Dismantalling of 11 KV VCB Pannel
Safe Cartage of Old received back 11 KV VCB Pannel from work site to ESC, Mirzapur including loading & unloading charge
Cartage of received back 25 KVA Transformer from work site to ESC, Mirzapur including loading & unloading charge
Cartage of received back 63 KVA Transformer from work site to ESC, Mirzapur including loading & unloading charge
Cartage of received back 100 KVA Transformer from work site to ESC, Mirzapur including loading & unloading charge
Cartage of received back 250 KVA Transformer from work site to ESC, Mirzapur including loading & unloading charge
ASTHA TRADERS
M.K.S Enterprises
stage.html
html • 0.03 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.01 MB
TDno.pdf
Tender Documents • 0.19 MB
BOQ_1383651.xls
BOQ • 0.31 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .