Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹49.4 LAccepted-AOC 15 MOULYA NMH LAYOUT 1ST STAGE CHIKKA BANAVARA POST BENGALURU 560 090 | BENGALURU URBAN | KARNATAKA | 560090 | ₹49.4 L Quoted ₹49.8 L | L1 | Accepted-AOC being L1 |
| 2 | L2₹50.0 L+₹12,920 (0.26%)Rejected-Finance | ₹50.0 L+₹12,920 (0.26%) | L2 | Rejected-Finance rejected being L2 |
| 3 | L3₹50.3 L+₹49,105 (0.99%)Rejected-Finance | ₹50.3 L+₹49,105 (0.99%) | L3 | Rejected-Finance rejected being L3 |
| 4 | L4₹52.1 L+₹2.3 L (4.60%)Rejected-Finance | ₹52.1 L+₹2.3 L (4.60%) | L4 | Rejected-Finance rejected being L4 |
| 5 | L5₹52.4 L+₹2.6 L (5.22%)Rejected-Finance | ₹52.4 L+₹2.6 L (5.22%) | L5 | Rejected-Finance rejected being L5 |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
9 Jul 2020, 6:00 pmClosed
GE I R AND D East Bangalore
GE RD East Bangalore 93
REPAIRS REPLACEMENT OF LIGHTENING ARRESTER AVIATION LIGHT EARTHING PIT EARTHING STRIP AND CONNECTED WORKS AT PHASEII UNDER GEI RD EAST BANGALORE
2020_MES_338493_1
8925
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE I R AND D East Bangalore
D b (i)
9 documents required · 9 mandatory
₹500
Yes
GE I R AND D East Bangalore
₹90,000
Yes
27 Aug 2020
11 Apr 2020
14 Jul 2020
11 Apr 2020
9 Jul 2020
5 Jul 2020
13 Apr 2020 - 27 Apr 2020
Amount
S & F single pointed air termination aluminium Rod , 12 mm dia 300 mm long complete all as directed
M&L Aluminium strip 25 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground along outer surface of OHT all as directed
S & F GI Strip 32 x 6 mm Size complete with sadles & screw for fitting the strip along with coloumn and to the top of the building all as directed
Refixing of GI strip of existing size with new porcelain holder and screws complete all as directed
M&L for GI pipe light grade 40 mm dia bore Including all fitings & fixture complete all as directed
M&L Earthing complete with galvanized cast iron earth plate electrode 600x600x6.0mm thick buried directly in ground( earth pit not less than 2.25 mtr deep below ground level) with top edge of earth plate not less than 1.50 mtr below normal ground level ,connected to galvanized iron lead using 4mm dia as earthing lead by means of nuts and bolts check nuts and washers of galvanized iron or steel all as shown on electrical plate No -3 of SSR 2009- Part 1 connected to earthing test point all as specified or indicated including testing on completion .
M & L for repair of earth pit chamber including funnel and earth pit cover complete all as specified and directed
M & L Test point terminal block made of Gun Metal or phosphorous Bronze size 75 x 75 x 25 mm drilled & Screwed incl 3 Nos 8 mm dia 25 mm long hexazonal head screwed and test register with details of result all as per dirction of Engineer -in- charge.
S & F in replacement of aviation obstruction light LED type comprising of aluminium housing with polycarbonate enclosure 302 Nos LED Provided complete all as specified and as directed Make : Bajaj Cat Part No BGAV 302 LED ort equivalent in Havells /CG/Phillips
S & F in replacement of LED driver suitable for LED street light fitings of capacity upto 70Watts of existing make complete
S & F in replacement of LED driver suitable for LED street light fitings of capacity upto 70 to 150Watts of existing make complete
M & L for GI bracket suitable for street light fittings bend to required shape of dia 40mm including clamps nuts bolts washers complete all as specified and directed
Supply and fix astronomical time switches along with timellite DBs without battery backup 3P module , 24 hours programme every 15min, current capacity 16A complete including necessary connectins and made functional all as specified and directed Make : Indo Asian Cat Part No : TL040A50 or equivalent
M & L for SMC enclosure dust, weather and vermin proof rain guarded cable entry and exist arrangement front side hinged door with closing arrangement SMC junction box of size 300 x 200 x 105mm complete all as specified Make : Sintex/Henson
Material and labour for servicing of control panels of Fire Hydrant Systems and checking of fuses , indication lamps, auto/manual function fault, indication switches, OL relays, contactor, SP Preventer and internal wirings etc including replacement of defective parts/spares with new one all as specified and directed by Engineer-in-Charge
Material and labour for servicing of electric motor with pump and overhauling /checking of pump alignment, gland packing and running performance witth replacement of suction pipe and foot valves, servicing of existing main pump 55KW capacity by dismantling the pump set from site, greasing and lubricating of pump spare parts and coupling, checking and correcting the alignment of pump with motor, coupling and shaft, checking of cable terminals, foundation bolts tightening replacement of unserviceable spares including painting , transpotation of pump set to work shop and bringing back site complete all as specified and as directed by Engineer-in-Charge
All as per item No. 16 here in before, but for booster and jockey pump of 7.5HP capacity with replacement section pipe line with foot valves all as directed by Engineer-in-Charge
Material and labour for servicing pump line control valves , gland packing and checking of spindle movement for smooth functioning all as directed by Engineer-in-Charge
Material and labour for servicing of hydrant single headed outlet , checking lug movement and applying grease, oiling as required for free movement, checking of spindle movement and inside coupling washer, gasket etc all as directed by Engineer-in-Charge
Material and labour for scrapping out old existing paint from fire hose box made of MS sheet 30" x 24" x 10" and applying two coats of synthetic enamel paint of existing color over a coat of red oxide primer for housing including fixing of new window pane and glass door beading complete all as directed by Engineer-in-Charge
Material and labour for servicing of sluice valve of 100mm size and checking of close and open operation of the valve , gland packing and replacement of gland packing, nuts bolts if required and arresting water leakages and painting all as directed and by Engineer-in-Charge
Material and labour for servicing of sluice valve of 80mm size and checking of close and open operation of the valve , gland packing and replacement of gland packing, nuts bolts if required and arresting water leakages and painting all as directed and by Engineer-in-Charge
M & L for repair & replacement of unserviceable stainless steel single headed fire hydrant valve supply installation, at location ttesting and commissioning of 63mm stainless steel single headed fire hydrant valve including gaskets nuts and bolts etc
M & L for replacement of unserviceable wall mounted MS ERW pipe of 100mm including taking down the old one complete all as specified and directed
Supply and replace of unserviceable canvas fire hose 63mm dia 15 mtrs long duly ISI marked with SS couplings from various location and testing and commissioning of peculating canvas fire hose 63mm dia reinforced tubular lined 15 mtr long with suitable male and female SS coupling on each and all as directed by Engr-in-Charge
Supply and replace of unserviceable dry riser piping 20mm dia ball valve all as specified and directed
Supply and replace of unserviceable 19mm reinforced rubber hose reel 30m long with MS drum all as directed by Engineer- in- Charge
Supply and replace unserviceable branch pipe with revolving head of size 63mm dia x 19mm dia all as directed by Engineer-in-Charge
Supply and replace unserviceable fire brigade 2 way inlet breeching having 2 stainless steel/Gun metal inlets of 63mm dry riser fitted non return valves at various locations including gaskets, nuts and bolts all as specified by Engineer-in-Charge
Supply and fix in replace of unserviceable fire hose box wall mounted made of MS sheet of 16 gauge 30" x 24" x 10" including painting with two coats of synthetic enamel paint existing colour over a coat of red oxide primerr for housing all as specified
Supply and replace gun metal gate valve with iron wheel head screwed both ends for iron pipe complete all as specified and directed
Supply and replace gun metal Fog Nozzle 63mm male installed inlet having arrangement for straight stream, high pressure fog and shut off chromium plated
Supply and replace Hose reel drum wall mounted swinging type of superior quality conforming to IS : 884 , duly ISI marked complete all as specified and directed
Material and labour for servicing of hose reel drum including greasing , replacement of nuts bolts to make free movement and rotation of drum complete all as specified and directed
Supply and fix CI Sluice valve confirm to PN 1.6 flanged of size 100mm complete all as specified and as directed
All as per item No.36 here in before but of size 80mm complete all as specified and directed
S&F brass spindle suitable for 100mm size sluice valve of PN 1.6 complete all as specified and directed
S&F brass spindle suitable for 80mm size sluice valve of PN 1.6 complete all as specified and directed
S&F in repairs ball cock complete with epoxy coated aluminium rod and HDPE Ball of size 20 mm dia complete. Make: Prayag
S&F in repairs ball cock complete with epoxy coated aluminium rod and HDPE Ball of size 25 mm dia complete. Make: Prayag
Taking down carefully U/S aluminium/ copper point wiring (light, fan,socket or power) complete with fittings such as switches, sockets, ceiling rose, light fittings etc , removing all material for reuse/ issued under sch of credit and making good the distrubed surface as the existing one, complete all as directed.
Point wiring complete with Multi stranded copper conductor size 1.5 sqmm PVC insulated, unsheathed,FRLS cable , 1100 volts grade conforming to IS 694 multistranded , drawn in and including rigid PVC conduit concealed in walls/ floors/ ceiling etc with and including metal flush boxes of suitable size and modular white plate with frame for mounting of fittings, modular type switches, regulator and also including 1.5 sqmm PVC insulated unsheathed copper cable green in colour as continuous earth continuity conductor and connecting to earth dolly,cutting chasis to the walls/ floors/ ceiling and repairing with existing surface after work ,complete all as specified and directed in Lift Room of Phase II Township
One light/fan/exhaust fan point controlled by one way switch
One 3 pin socket point 5 Amps on the independent board.
All as per item No 42 here-in-before but using copper conductor 2.5 sqmm PVC insulated unsheathed FRLS cable with copper conductor size 1.5 sqmmm PVC insulated unsheathed continuous earth continuity for 3 pin 15 amps soket outlet independently all as specified and as directed by Engr-in-charge.
Supply & fix switch modular type single pole 1 way 5 Amp 230 volt complete as directed.
Supply & fix socket 6 Amps modular type, 230 volts grade all as directed.
Supply & fix switch modular type 1 way 16A, 1 module all as specified and directed.
Supply & fix Socket Modular type 6A/16A 2-3pin combined 2 module 230Volts grade all as directed.
Supply & fix ceiling rose surface bakelite two to three terminal complete all as directed.
Fixing only LED 4 feet fitting of any type and wattage including connecting to ceiling rose with twin copper conductor of size 0/0.24 complete all as specified and directed by Engr-in Charge Note :- Fittings will be issued by the Department under Sch 'B'-free for fixing only
Dismantling the ceiling fan/exhaust fan complete of any type and size , cleaning, servicing, greasing to bearings checking of nuts bolts , safety split pin, bushes , capacitor and complete testing all as directed Note :- Expendable stores like cotton waste/cleaning materials, grease, lubricants, machine screws, safety split pin, bots/nuts and transportation to and from site to work place are deemed to be included in rate quoted
Taking down defective Geyser /Storage water heater of any pattern/capacities from existing position/place comprising of the following tasks :- (a) Inspection , taking down (dismantling ), descalling, brushing, cleaning of storage tank & painting internally with one coat of proprietary bituminous composition not liable to impart taste or odour or otherwise contaminate water. (b) Examine water tightness of storage tank after cleaning. (c) Carryout operation of all stopcosk, pressure reducing valves etc to enure free movement of the working parts. (d) Replace washers and glands of all taps & ball valves to ensure water tightness. (e) Inspect oferflow/vent pipes & remove blockages obstructions if any. (f) Check and correct earth continuity of electrical parts.
(g) Check,maintain and refit thermostats & test its functioning. (h) Checking and adjustment of pressure reducing valve (j) Checking of dead weight type high pressure release valve (HPRV) by removing dead weight position cleaning the seat & ensuring that the vent hole is not blocked/chocked.
(k) Visual examination of fusible plug to ensure its intactness. (l) Descalling of the immersion type heating element cleaning with diluted, hydrochloric acid solution & testing before refitting. (m) Replacement of the rubber /PVC gasket to ensure water tightness. (o) Testing of geyser after repairs. (p) Refixing of geyser after testing & replacement of defective parts including new hold -fastened incuding necessary PCC work complete all as specified and directed
S&F in replacement heating element of 2KW rating as required at site including rubber washers of ISI marked.
Supply in replacement of thermostat for the geyser of following capacities with ISI marked :-
S & F in repalcement of PVC connection pipe with two brass adaptors 450mm long & connecting up complete all as specified and directed
M & L for painting external part of the geyser body at site/existing position with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning complete all as specified and directed
SREE BUILDERS
Vinayaka Enterprises
Kaveri Enterprise
Power and Telecom Systems
Meghana and Gowda Enterprises
K. VENKATESH NAIDU
ARATHEERTHA CONCEPTS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .