| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.5 CrAccepted-AOC KESHAV NAGAR MANORA ROAD DIGRAS TQ DIGRAS DISST YAVATMAL 445203 | DIGRAS | YAVATMAL | MAHARASHTRA | 445203 | ₹1.5 Cr | L1 | Accepted-AOC Biddar is L1 hance Awarded Tender |
| 2 | L2₹1.6 CrRejected-Finance B K PLOT OPP MRF SHOW ROOM NEAR SHIVAJI SCHOOL WASHIM ROAD PUSAD TQ PUSAD DIST YAVATMAL | ₹1.6 Cr | L2 | Rejected-Finance Biddar is L2 hance Reject |
| 3 | L3₹1.6 CrRejected-Finance | ₹1.6 Cr | L3 | Rejected-Finance Biddar is L3 hance Reject |
| 4 | L4₹1.6 CrRejected-Finance DARWHA | DARWHA | YAVATMAL | MAHARASHTRA | ₹1.6 Cr | L4 | Rejected-Finance Biddar is L4 hance Reject |
| 5 | L5₹1.7 CrRejected-Finance NOT AVAILABLE | ₹1.7 Cr | L5 | Rejected-Finance Biddar is L5 hance Reject |
| Sl No | Description | Qty | Unit | R F Agrawal Construction Private Limited L12 | Audarya Construction Private Limited L9 | Dhananjay Rajaram Mahajan L7 | P K JADHAV CONSTRUCTION COMPANY L10 | M/s B. K. Construction L2 | KANHOBA CONSTRUCTION PVT.LTD L1 | M/S. R T RATHI L8 | Stratum Consultancy Services Private Limited L5 | Raju N Nakshane L3 | GIRISH JAMANADAS CHANDAK L13 | M/s NAWAB CONSTRUCTION COMPANY, PUSAD L6 | AGM CONSTRUCTION COMPANY L4 | JAGANNATH CONSTRUCTION COMPANY L11 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 1000 m as per Technical Specification Clause 202. | 166.66 | Cum | 890 ₹1.5 L | 800 ₹1.3 L | 937 ₹1.6 L | 843 ₹1.4 L | 750 ₹1.2 L | 703.92 ₹1.2 L | 297 ₹49,499.51 | 297 ₹49,499.51 | 500 ₹83,332.50 | 1,100 ₹1.8 L | 750 ₹1.2 L | 795.21 ₹1.3 L | 874.88 ₹1.5 L |
| 2.00 | Removing all types of Hume pipes and stacking within a lead of 1000 m including Earthwork and Dismantalling of Masnory Works as per Technical Specification Clause 202. | 90 | Rmt | 529 ₹47,610 | 500 ₹45,000 | 588 ₹52,920 | 529.29 ₹47,636.10 | 500 ₹45,000 | 441.67 ₹39,750.30 | 184 ₹16,560 | 184 ₹16,560 | 300 ₹27,000 | 1,000 ₹90,000 | 750 ₹67,500 | 498.94 ₹44,904.60 | 548.93 ₹49,403.70 |
| 3.00 | Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material.. I. ORDINARY SOIL | 918.6 | Cum | 603 ₹5.5 L | 500 ₹4.6 L | 670 ₹6.2 L | 603.22 ₹5.5 L | 550 ₹5.1 L | 503.36 ₹4.6 L | 223 ₹2.0 L | 223 ₹2.0 L | 350 ₹3.2 L | 550 ₹5.1 L | 600 ₹5.5 L | 568.64 ₹5.2 L | 625.61 ₹5.7 L |
| 4.00 | Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material.. II. ORDINARY ROCK (NOT REQUIRED BLASTING) | 137.54 | Cum | 712 ₹97,928.48 | 700 ₹96,278 | 838 ₹1.2 L | 754.05 ₹1.0 L | 680 ₹93,527.20 | 629.18 ₹86,537.42 | 434 ₹59,692.36 | 434 ₹59,692.36 | 550 ₹75,647 | 1,200 ₹1.7 L | 580 ₹79,773.20 | 709.85 ₹97,632.77 | 782.05 ₹1.1 L |
| 5.00 | Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material.. III. HARD ROCK (REQUIRED BLASTING) | 107.5 | Cum | 1,188 ₹1.3 L | 1,000 ₹1.1 L | 1,291 ₹1.4 L | 1,161.7 ₹1.2 L | 1,032 ₹1.1 L | 969.4 ₹1.0 L | 1,506 ₹1.6 L | 1,506 ₹1.6 L | 700 ₹75,250 | 1,000 ₹1.1 L | 740 ₹79,550 | 1,095.11 ₹1.2 L | 1,204.83 ₹1.3 L |
| 6.00 | Dewatering on BHP basis by using water pump including diversion of stream, providing cofferdams, earthern bunds etc. as may be necessary for foundation and other parts of the the works and pumping out water during and after excavation as may be required by using 5.0 to 9.0 BHP pump etc. complete. (prior approval of Superintending Engineer will be necessary) | 240 | Hour | 185 ₹44,400 | 225 ₹54,000 | 201 ₹48,240 | 180.9 ₹43,416 | 150 ₹36,000 | 150.96 ₹36,230.40 | 156 ₹37,440 | 156 ₹37,440 | 100 ₹24,000 | 170 ₹40,800 | 160 ₹38,400 | 170.53 ₹40,927.20 | 187.61 ₹45,026.40 |
| 7.00 | Dewatering on BHP basis by using water pump including diversion of stream, providing cofferdams, earthern bunds etc. as may be necessary for foundation and other parts of the the works and pumping out water during and after excavation as may be required by using 10.0 to 19.0 BHP pump etc. complete. (prior approval of Superintending Engineer will be necessary) | 160 | Hour | 205 ₹32,800 | 250 ₹40,000 | 223 ₹35,680 | 200.7 ₹32,112 | 180 ₹28,800 | 167.48 ₹26,796.80 | 156 ₹24,960 | 156 ₹24,960 | 100 ₹16,000 | 170 ₹27,200 | 160 ₹25,600 | 189.2 ₹30,272 | 208.15 ₹33,304 |
| 8.00 | Providing concrete for plain concrete M-15 in open foundations complete as per drawings and Technical Specification Clauses 802, 803, 1202 and 1203. | 20.29 | Cum | 6,065 ₹1.2 L | 6,000 ₹1.2 L | 6,253 ₹1.3 L | 5,627.5 ₹1.1 L | 3,500 ₹71,015 | 4,695.86 ₹95,279 | 6,252.8 ₹1.3 L | 6,252.8 ₹1.3 L | 6,000 ₹1.2 L | 6,200 ₹1.3 L | 6,200 ₹1.3 L | 5,304.88 ₹1.1 L | 5,836.36 ₹1.2 L |
| 9.00 | Filling annular space around footing in rock as per technical specification Clause 1203.4.3. | 55.07 | Cum | 5,680 ₹3.1 L | 6,000 ₹3.3 L | 4,733 ₹2.6 L | 5,680.08 ₹3.1 L | 4,000 ₹2.2 L | 4,739.72 ₹2.6 L | 5,200 ₹2.9 L | 5,200 ₹2.9 L | 6,500 ₹3.6 L | 5,800 ₹3.2 L | 3,500 ₹1.9 L | 5,354.42 ₹2.9 L | 5,890.87 ₹3.2 L |
| 10.00 | Providing concrete for plain concrete M-25 in open foundations complete as per drawings and Technical Specification Clauses 802, 803, 1202 and 1203. | 44.17 | Cum | 6,581 ₹2.9 L | 7,000 ₹3.1 L | 7,154 ₹3.2 L | 6,438.15 ₹2.8 L | 6,000 ₹2.7 L | 5,372.28 ₹2.4 L | 7,000 ₹3.1 L | 6,450 ₹2.8 L | 7,500 ₹3.3 L | 7,500 ₹3.3 L | 6,750 ₹3.0 L | 6,069.02 ₹2.7 L | 6,677.08 ₹2.9 L |
Tender Value
Refer Docs
EMD Value
₹2.0 L
Closing Date
24 Oct 2025, 6:00 pmClosed
Superintending Engineer PMGSY MRRDA Amravati Regio
office of Superintending Engineer PMGSY MRRDA Commissioner office Amravati Region Amravati
Construction of Bridge on MSH-06 (Taroda) to Gangaon Tq. Border Ch. 1/480 Tq. Arni
2025_MMGSY_1225382_1
EE/PMGSY/YTL/NIT/161/2025-26
Open Tender
Civil Works - Bridges
547 days
Arni
Please refer Tender documents.
3 documents required · 3 mandatory
₹11,800
₹2.0 L
16 Dec 2025
6 Oct 2025
27 Oct 2025
6 Oct 2025
24 Oct 2025
6 Oct 2025
6 Oct 2025 - 8 Oct 2025
Amount
Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 1000 m as per Technical Specification Clause 202.
Removing all types of Hume pipes and stacking within a lead of 1000 m including Earthwork and Dismantalling of Masnory Works as per Technical Specification Clause 202.
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material.. I. ORDINARY SOIL
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material.. II. ORDINARY ROCK (NOT REQUIRED BLASTING)
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material.. III. HARD ROCK (REQUIRED BLASTING)
Dewatering on BHP basis by using water pump including diversion of stream, providing cofferdams, earthern bunds etc. as may be necessary for foundation and other parts of the the works and pumping out water during and after excavation as may be required by using 5.0 to 9.0 BHP pump etc. complete. (prior approval of Superintending Engineer will be necessary)
Dewatering on BHP basis by using water pump including diversion of stream, providing cofferdams, earthern bunds etc. as may be necessary for foundation and other parts of the the works and pumping out water during and after excavation as may be required by using 10.0 to 19.0 BHP pump etc. complete. (prior approval of Superintending Engineer will be necessary)
Providing concrete for plain concrete M-15 in open foundations complete as per drawings and Technical Specification Clauses 802, 803, 1202 and 1203.
Filling annular space around footing in rock as per technical specification Clause 1203.4.3.
Providing concrete for plain concrete M-25 in open foundations complete as per drawings and Technical Specification Clauses 802, 803, 1202 and 1203.
Providing concrete for plain concrete M-30 in open foundations complete as per drawings and Technical Specification Clauses 802, 803, 1202 and 1203.
Supplying, fitting and placing TMT (Fe-500) bar reinforcement in foundation complete as per drawing and technical specification clauses 1000 and 1202
Plain cement concrete M-25 in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204
Reinforced cement concrete M-30 in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204
Supplying, fitting and placing TMT (Fe-500) bar reinforcement in substructure complete as per drawing and technical specification clauses 1000 and 1202
Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia PVC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7
Providing and laying 0.90 meter thick metal mat consisting of rubble, oversize metal and normal size metal in specified thickness as per detailed drawing including supplying all materials, hand packing of rubble, spreading metal in layers and hard murum including watering and compaction with power roller etc. complete.
Backfilling behind abutment, wing wall and return wall complete as per drawings & technical specification Clause 1204.3.8
Providing and laying filter media with granular crushed aggregates as per specification to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and providing over the entire surface behind abutment, wing wall, return wall to the full height, compacted to firm condition complete as per drawing and technical specification Clause 1204.3.8
Providing and laying reinforced cement concrete M-30 in superstructure as per drawing and technical specifications Clauses 800, 1205.4 and 1205.5
Providing and laying cement concrete wearing course M 30 grade including reinforcement complete as per drawing and technical specifications Clauses 800 and 1206.3
Providing and laying reinforced cement concrete M-20 in superstructure as per drawing and technical specifications Clauses 800, 1205.4 and 1205.5
Supplying, fitting and placing TMT bar reinforcement (Fe 500) in superstructrue complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202
Providing Tar paper bearing of approved quality in proper size etc. complete.
Expansion joint with 25 mm thich bituminous pad.
Painting two coat including prime coat after filling the surface with synthetic enamel paint in all shades on new, plastered / concrete surface as per drawing and technical specification clause 1701
Providing and fixing in position pipe railing consisting of IS Rolled steel joist posts designation IS MB 100 (100x50) at 2.5 m interval and three rows of 50 mm dia steel pipes (light) including fixing in position on bridge deck complete as per drawing and technical specifications Clause 1208.2
Providing and fixing Granite / Marble tablet of 15mm to 18mm thickness ,including making groove in wall / concrete surface filling joints with slurry, curing, polishing, rounding edges, as required cleaning etc. complete. of size and description as per detailed drawings including embossing & fitting in 1:2 C.M. border.
Clearing grass and removal of rubbish up to a distance of 30 m outside the periphery of the area as per Technical Specification Clause 201.
Excavation for roadway in soil by mechanical means including cutting and pushing the earth to site of embankment upto a distance of 100 m, including trimming bottom and side slopes in accordance with requirements of lines, grades and cross-sections.
Construction of embankment with approved materials deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacted to meet requirement of Tables 300.1 and 300.2 as per Technical Specification Clause 301.5
Construction of embankment with approved material obtained from borrow pits with a lift upto 1.5 m, transporting to site, spreading , grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2 as per technical Specification Clause 301.5
Loosening, Levelling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in Tables 300.1 and 300.2 for embankment construction as per Technical Specification Clause 301.4.1.
Construction of Subgrade Layer with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 with lead upto 1000 m as per Technical Specification Clause 303.1.
Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401.
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with three wheel 80-100 kN static roller in stages to proper grade and camber, applying and brooming, crushable screening to fill-up the interstices of coarse aggregate, watering and compacting to the required density Grading 2 as per Technical Specification Clause 405.
Construction of Earthen Shoulders as per Technical Specification Clause 407.
Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.20 to 0.25 kg per sqm on the prepared bituminous surface cleaned with Hydraulic broom as per Technical Specification Clause 503.
Construction of modified penetration macadam 50mm thick over prepared base by providing a layer of compacted crushed coarse aggregate using chips spreader with alternate applications of bituminous binder of VG-30 Grade @1.75kg/sq.meter and key aggregates and rolling with a three wheel 80-100 kN static roller to achieve the desired degree of compaction as per Technical Specification Clause 506.
Providing, laying and rolling of open-graded premix carpet of 20 mm thickness composed of 13.2 mm to 5.6 mm aggregates either using penetration grade bitumen or emulsion to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 80-100 kN static roller capacity, finished to required level and grades to be followed by seal coat of either Type A or Type B or Type C as per Technical Specification Clause 508.
Providing and laying Premix seal coat sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using Type A, Type B and Type C as per Technical Specification Clause 510
Metal Beam Crash Barrier-Type-A, W: Metal Beam Crash Barrier (Providing and erecting a W "metal beam crash barrier comprising of 3 mm thick corrugated Metal Beam Crash Barrier-Type-A, W: Metal Beam Crash Barrier (Providing and erecting a W "metal beam crash barrier comprising of 3 mm thick corrugated sheet metal beam rail, 70 cm above road/ground level, fixed on ISMC series channel vertical post, 150 x 75 x 5 mm spaced 2 m centre to centre, 1.8 m high, 1.1m below ground/road level, all steel parts and fitments to be galvanised by hot dip process, all fittings to conform to 1367 and 15:1364, metal beam rail to be fixed on the vertical post with a spacer of channel section 150 x 75 x 5 mm, 330 mm long complete as per clause 810)"
Providing and Laying hot applied thermoplastic road marking strip on Bituminous Surface of specified shade/ colour of 2.5 mm thick including 1.5 Refractive index reflectorizing glass beads @ 250gm/sqm .Thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC 35:2015. Initial Dry reflectivity RL shall be > 250 mcd/sqm/lux measured in the initial 7 days and sustained reflectivity RL of 100 mcd/sqm/ lux and Qd of 100 mcd/sqm/ lux measured at the end of 2 years by means of a Standard Reflectometer of Zehntner, Easylux, Delta make capable of measuring RL & QD both according to IRC 35:2015 clause 15.5.The finished surface to be level, uniform, and free from streaks and holes complete as per direction of Engineer-in-charge and in accordance with applicable specifications.(Refer MORTH Clause 803 for technical Specification and Performance for IRC 35:2015).
Providing and laying 600 mm dia reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106.
Supplying and Fixing of Molded Shank Raised Pavement Markers / Cat's Eye made of polycarbonate and ABS moulded body and reflective panels with micro prismatic lens capable of providing total internal reflection of the light entering the lens face and shall support a load of 16000 kg tested in accordance to ASTM D 4280 Type H and complying to Specifications of Category A of MORTH Circular No RW/NH/33023/10-97 DO III Dt 11.06. 1997. The height, width and length shall not exceed 50 mm, 100 mm and 102 +/- 2 mm and with minimum reflective area of 13 Sqcm on each side and the slope to the base shall be 35 +/- 5 degree. The strength of detachment of the integrated cylindrical shanks, (of diameter not less than 19 +/- 2 mm and height not less than 30+/- 2 mm) from the body is to be a minimum value of 500 Kg. Fixing will be by drilling holes on the road for the shanks to go inside, without nails and using epoxy resin based adhesive as per manufacturer's recommendation and complete as directed by the engineer.The contractor shall submit a two year warranty for satisfactory field performance including stipulated retro-reflectance of the reflecting panel, to the Engineer.
Providing Vertical Delineator having wide angle cube corner micro prismatic non metallic reflective sheeting confirming to Type XI of ASTM D4956 -09 with White Color and Red Color combination and having minimum of retro reflective exposed area of 125 Sq CM on top slots and 35 Sq CM on bottom slots and no edges shall be exposed for tampering. This tubular delineator shall have a core and shell construction, shell shall be made of tough, high impact resistant, injection-molded, thermoplastic outer body and the inner core shall consist of powder coated or painted Mild steel of minimum thickness 1.0mm.and core-shell structure shall be of height not less than 800 mm above the ground and width not less than 80 mm. The metallic core of the delineator shall extend 300mm beyond the shell length from bottom for installing in the ground. The extended portion shall have slots to insert anchoring rods for enhancing the concrete grip. The logo of the manufacturer shall be embossed on either side of the body in the injection molding process. The engineering thermoplastic used for making the delineator body shall have minimum initial mechanical properties of 600J/m tested in accordance with ASTM D256 and shall retain at least 70% of these minimum initial values when subjected to accelerated weathering for 1000hrs as per ASTM G155 or UL 746C and as per IRC 79 specifications and including fixing the unit in M20 Grade Cement Concrete of Size 30x30x40 cm including excavation for pit.
Providing and erecting direction and place identification retro-\reflectorised sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3, fixed over aluminium sheeting, 2 mm thick with area exceeding 0.9 sqm supported on mild steel angle iron posts 75 mm x 75 mm x 6 mm, 2 Nos. firmly fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per approved drawing and Technical Specification Clause 1701
Providing and fixing of semi reflective cautionary, mandatory and informatory sign board as per IRC:67 made of 1.5 mm thick MS Sheet duly stove white colour in front and gray colour on back with red reflective border of 65 mm width and required letters and figures with reflective tape engineering grade as per Clause 1701.3.9 of MORD for Rural Roads of required shade and colour supported and welded on 47mm x 47 mm x 12 SWG sheet tube firmly fixed to the ground by mean of properly designed foundations with M-15 grade cement concrete 450x450x600 mm, 600 mm below ground level as per approved drawing Clause 1701.2.2
Providing and fixing Cautionary/Warning sign boards in Equilateral Triangle size of 600 mm made out of 3 mm aluminum sheet bonded with white retro reflective sheeting of Class B ( Type IV High intensity micro-prismatic grade sheeting-HIP) having pressure sensitive/heat activated adhesive retoreflective specified back ground, border and back side retoreflctive symbols, letters, numerals, arrow as per IRC:67-2012 Table No 8.3 Supported with back support frame 25mm x 25mm x 3mm, duly painted on back side with grey stove enamel paint and supported on one no. of M. S. angle iron post of size 65 mm X 65 mm X 6 mm, 3.45 m long, duly painted with with flat oil paint having alternate black and white bands of 25 cm width including G.I. fixtures etc; fixing the boards in M25 grade concrete block of size 60cm X 60cm X 75cm including transportation etc; complete. Class B ( Type IV High intensity micro-prismatic grade sheeting-HIP) shall have 7 years written warranty from the manufacturer and authorised distributor/convertor issued for field performance including the screen printed areas and cut-out sheeting and cut-out durable transparent overlay film and this warranty certificate in original should be submitted to the Engineer in charge by the contractor/supplier.
Providing and fixing Cautionary/Warning sign boards in Equilateral Triangle size of 900 mm made out of 2 mm aluminum sheet bonded with white retro reflective sheeting of Class B ( Type IV High intensity micro-prismatic grade sheeting-HIP) having pressure sensitive/heat activated adhesive retoreflective specified back ground, border and back side retoreflctive symbols, letters, numerals, arrow as per IRC:67-2012 Table No 8.3 Supported with back support frame 25mm x 25mm x 3mm, duly painted on back side with grey stove enamel paint and supported on one no. of M. S. angle iron post of size 65 mm X 65 mm X 6 mm, 3.45 m long, duly painted with with flat oil paint having alternate black and white bands of 25 cm width including G.I. fixtures etc; fixing the boards in M25 grade concrete block of size 60cm X 60cm X 75cm including transportation etc; complete. Class B ( Type IV High intensity micro-prismatic grade sheeting-HIP) shall have 7 years written warranty from the manufacturer and authorised distributor/convertor issued for field performance including the screen printed areas and cut-out sheeting and cut-out durable transparent overlay film and this warranty certificate in original should be submitted to the Engineer in charge by the contractor/supplier.
Providing and Fixing 'Logo' of MMGSY Project: Providing and fixing Retro Reflective MMGSY / PMGSY LOGO informatory sign board with Logo as per section1700 of MORD specifications and latest PMGSY Signage Manual / Circular and drawing. The board will be a composite unit consisting of Two Plates of ACP (Aluminum Composite Panel), material specifications as per clause 17001.3. The top most plate will be of 3 mm ACP in diamond shape of 600x600mm size, riveted with MS angle iron frame of 25mmx25mmx5mm size on back on edges. The Lower plate will be of 4mm ACP of 1100x300mm size riveted with MS angle iron frame of 25mmx25mmx5mm size on back on edges. Riveting of all the sheets over angle and flat iron frame will be done neatly to have plain surface on one side. The angle iron frame of Both the plates will be welded to a 75mm x75mmx 12swg Mild steel post at / Tube Centre and this post will be embeded in cement concrete M15 grade block of x450x600mm below ground level. The height of the bottom of the lower plate will be 1200mm from normal ground level. The spacing between the diamond shaped plate and Lower Plate is kept 150mm. MMGSY / PMGSY logo, letters and numerals on the ACP should be made up of Retro Reflective sheeting of Class-B grade as per the latest MORD section 1700 specifications (Refer Circuler no. NRRDA-P013(11)/3/2019-Dir (Tech) dated 02.12.2019). Printing PMGSY logo/MMGSYLogo/Project description on Class B type retro reflective sheeting using modern technology printing platform. The printer shall be approved by the retro reflective sheeting manufacturer and printed sign shall conform to retro reflective values as laid down in IRC 67-2022. The inks used for printing shall be eco friendly with VOC emissions complying to UL 2801 standards and specifications for the different kinds of platforms. The printed sign shall be laminated by UV protected laminate and shall carry a warranty of 7 years for Class B sheeting respectively for traffic colors.”All the section of the frame and posts shall be painted with primer and two coats of epoxy paint. The design, painting and lettering shall be done as per the PMGSY signage manual Fig.1 (A) and Fig.1 (B) and as directed by Engineer in-charge. A warranty for 7 years for the Retro reflective sheeting for Class-B respectively, from original manufacturer shall be submitted by contractor.
MMGSY Citizen' s information Board: Providing and fixing of typical PMGSY Retro Reflective information board as per as per section1700 of MORD specifications and latest PMGSY Signage Manual / Circuler and drawing.Two ACP (Aluminum Composite Panel) sheets of 4 mm thick, of 900 mm x 750mm size fixed at top & bottom duly rivetted with MS angles of 35 x 35 x 5 mm thick M.S angle shall be welded by two vertical M.S angle of 5 mm thick to 75 mm x 75 mm of 12 SWG square tubes / 75mm Dia Pipe posts duly embedded in cement concrete M-15 grade blocks of 600mm x 600mm x 75mm, below ground level. MMGSY / PMGSY logo, letters and numerals on the ACP should be made up of Retro Reflective sheeting of Class-B grade as per the latest MORD section 1700 specifications (Refer Circuler no. NRRDA-P013(11)/3/2019-Dir (Tech) dated 02.12.2019). Printing PMGSY Logo/MMGSY Logo/Project description on Class B type retro flective sheeting using modern technology printing platform. The printer shall be approved by the retro reflective sheeting manufacturer and printed sign shall conform to retro reflective values as laid down in IRC 67-2022. The inks used for printing shall be eco friendly with VOC emissions complying to UL 2801 standards and specifications for the different kinds of platforms. The printed sign shall be laminated by UV protected laminate and shall carry a warranty of 7 years for Class B sheeting respectively for traffic colors. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paints as per drawing Clause 1701 and Annexure 1700.1 (10.16). The design, painting and lettering shall be done as per the PMGSY Signage Guidelines Fig.3 and Fig.4 and as directed by Engineer-In-charge. . A warranty for 7 years for the Retro reflective sheeting for Class-B respectively, from original manufacturer shall be submitted by contractor.
Sign Board of MMGSY Project Information: Providing and fixing of typical retro reflective MMGSY / PMGSY Project informatory sign board with Logo as per section1700 of MORD specifications and latest PMGSY Signage Manual / Circuler and drawing. The board will be a composite unit consisting of Three Plates ACP (Aluminum Composite Panel), material specificaitons as per clause 17001.3. The top most plate will be of 3mm ACP in diamond shape of 600x600mm size, riveted with MSangle iron frame of 25mmx25mmx5mm size on back on edges. The middle 4mm ACP plate of will be 1200x150mm size riveted with MS angle iron frame of 25mmx25mmx5mm size on back on edges. The main 4mm ACP lower most plate will be 1500mmx600mm size, riveted with MS angle iron frame of 25mmx25mmx5mm size. Riveting of all the sheets over angle and flat iron frame will be done neatly to have plain surface on one side. The angle iron frame of lower most plate and flat iron frame of the middle plate will be welded to two nos. 75mm x75mm x 12 swg sheet tubes posts placed at 1125mm apart centre to centre. the top of the middle plate will be flushed with the top of 75mm dia medium steel tube posts and these posts will be embeded in cement concrete M15 grade block of 450x450x600mm below ground level. The height of the bottom of the lower plate will be 1200mm from normal ground level and the bottom of the middle plate will be 100mm above the top level of the lower most plate. the diamond shaped plate mounted over flat angle iron frame will be connected tomiddle plate by square steel section of 47mmx47mm, thickness 12SWG having a spacing of 100mm between the diamond shaped plate and middle plate and this square section will be riveted to the bottom point of the diamond shaped plate. MMGSY / PMGSY logo, letters and numerals on the ACP should be made up of Retro Reflective sheeting of Class-A / Class-B grade as per the latest MORD section 1700 specifications (Refer Circuler no. NRRDA-P013(11)/3/2019-Dir (Tech) dated 02.12.2019). Printing PMGSY Logo/MMGSY Logo/Project description on Class B type retro reflective sheeting using modern technology printing platform. The printer shall be approved by the retro reflective sheeting manufacturer and printed sign shall conform to retro reflective values as laid down in IRC 67-2022. The inks used for printing shall be eco friendly with VOC emissions complying to UL 2801 standards and specifications for the different kinds of platforms. The printed sign shall be laminated by UV protected laminate and shall carry a warranty of 7 years for Class B sheeting respectively for traffic colors. All the section of the frame and posts shall be painted with primer and two coats of epoxy paint. The design, painting and lettering shall be done as per the PMGSY Signage Guidelines Fig.2 and as directed by Engineer-In-charge. . A warranty for 7 years for the Retro reflective sheeting for Class-B respectively, from original manufacturer shall be submitted by contractor.
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material.
Providing concrete for plain concrete M-10 in open foundations complete as per drawings and Technical Specification Clauses 802, 803, 1202 and 1203.
Reinforced cement concrete M-25 in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204
Supplying, fitting and placing TMT (Fe-500) bar reinforcement in foundation complete as per drawing and technical specification clauses 1000 and 1202
Supplying, fitting and placing TMT (Fe-500) bar reinforcement in substructure complete as per drawing and technical specification clauses 1000 and 1202
Providing and laying filter media with granular crushed aggregates as per specification to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and providing over the entire surface behind abutment, wing wall, return wall to the full height, compacted to firm condition complete as per drawing and technical specification Clause 1204.3.8
Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia PVC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7
Providing and laying pitching on slopes laid over prepared filter media as per drawing and technical specifications Clause 1302
Providing and laying filter material underneath pitching in slopes complete as per drawing and technical specifications Clause 1302
Construction of toe walls for protection of slopes as per drawing and technical specifications Clause 1302.5
M/s B. K. Construction (BID ID -6947723)
Raju N Nakshane (BID ID -6953256)
AGM CONSTRUCTION COMPANY (BID ID -6951425)
Stratum Consultancy Services Private Limited (BID ID -6948312)
M/s NAWAB CONSTRUCTION COMPANY, PUSAD (BID ID -6948623)
Dhananjay Rajaram Mahajan (BID ID -6937289)
M/S. R T RATHI (BID ID -6947981)
Audarya Construction Private Limited (BID ID -6936671)
P K JADHAV CONSTRUCTION COMPANY (BID ID -6941968)
JAGANNATH CONSTRUCTION COMPANY (BID ID -6953438)
R F Agrawal Construction Private Limited (BID ID -6932720)
GIRISH JAMANADAS CHANDAK (BID ID -6953419)
stage.html
html • 0.07 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.31 MB
ADBYAV_BR_03.pdf
Tender Documents • 2.40 MB
BOQ_2114858.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid