| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.7 LAccepted-AOC | ₹17.7 L | L1 | Accepted-AOC L1 bidder |
| 2 | L2₹19.0 LRejected-Finance | ₹19.0 L | L2 | Rejected-Finance Other than L1 |
| 3 | L3₹20.0 LRejected-Finance | ₹20.0 L | L3 | Rejected-Finance Other than L1 |
| Sl No | Description | Qty | Unit | CHINAR CONSTRUCTION TRADERS L2 | M/s Nasir Rasool Dar L1 | M/S Noor Mohammad Shalla L3 |
|---|---|---|---|---|---|---|
| 1.00 | Excavating in trenches not exceeding 1.5 meter wide and not exceeding 1.5 meter in depth for foundation for erection of poles, stays, laying cables, stays etc and getting out in any type of soil all as specified and as directed. | 44.5 | Cum | 150 ₹6,675 | 20 ₹890 | 80 ₹3,560 |
| 2.00 | Returning filling in excavated earth work including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and directed. | 38 | Cum | 60 ₹2,280 | 10 ₹380 | 40 ₹1,520 |
| 3.00 | Removing surplus excavated soil to a distance not exceeding 50m, depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed. | 10.6 | Cum | 60 ₹636 | 5 ₹53 | 30 ₹318 |
| 4.00 | Supply and laying dry sand laid in trenches as cable cushioning and covering complete all as specified and directed.
Note : Punned thickness only will be measured and Paid | 4.1 | Cum | 700 ₹2,870 | 200 ₹820 | 500 ₹2,050 |
| 5.00 | Supplying and laying un-reinforced precast concrete cable cover, class HV, type 1 with peak, size 300mm x 180mm x 40mm, complete all as specified and directed. | 650 | Each | 10 ₹6,500 | 10 ₹6,500 | 40 ₹26,000 |
| 6.00S&F in trenches /on wall in repairs GI tubing medium grade for road crossing and cable protection of the following sizes :- | ||||||
| 6.01 | 80mm dia | 6 | RM | 400 ₹2,400 | 200 ₹1,200 | 300 ₹1,800 |
| 6.02 | 100mm dia | 6 | RM | 500 ₹3,000 | 200 ₹1,200 | 400 ₹2,400 |
| 7.00 | Material and labour for providing new ACSR conductor including stringing through existing RCC poles, fixing in insulators, jumpers with polythene pipe, aluminium binding wire etc complete of different sizes including dismantling of existing old unserviceable ACSR of any size from any descritpion complete all as specified and directed.
Note : Rates for new Aluminium cable terminal lugs are included in rate quoted. | 0.2 | Qtl | 25,000 ₹5,000 | 2,000 ₹400 | 1,500 ₹300 |
| 8.00 | S&F in replacement of Galvanaised Iron / Mild Steel cross arms channel, bracing, support, clamps etc fabricated structured steel, sections, including nuts, bolts, washers etc and cutting to required length beat to any shape drilling holes, fixed on poles or jointed by means of elect welding complete including painting with 2 coats of aluminum paint over a coat of red oxide primer after preparation of surfaces complete all as specified and directed. | 2 | Qtl | 10,000 ₹20,000 | 2,000 ₹4,000 | 5,000 ₹10,000 |
Updated dates
Tender Value
₹32.5 L
EMD Value
₹65,000
Closing Date
10 Dec 2025, 6:00 pmClosed
Col P Canon Anal CWE
HQ 134 WE C/o 56 APO PIN-914134
REPAIR AND MAINT OF 11 KV AND 33 KV HT ELECT INSTALLATIONS INCLUDING CONNECTED ITEMS SUCH AS TRANSFORMERS VCBs CT PT GOD DO FUSES AVR CABLES ETC AT MANASBAL UNDER AGE E M OF GE 970 EWS
2025_MES_739498_1
134WE-81(T)/2025-26
Open Tender
Civil Works - Others
180 days
GE 970 EWS
As per tender documents
8 documents required · 8 mandatory
₹500
GE 970 EWS
₹65,000
31 Dec 2025
12 Nov 2025
12 Dec 2025
12 Nov 2025
10 Dec 2025
26 Nov 2025
12 Nov 2025 - 19 Nov 2025
Amount
Excavating in trenches not exceeding 1.5 meter wide and not exceeding 1.5 meter in depth for foundation for erection of poles, stays, laying cables, stays etc and getting out in any type of soil all as specified and as directed.
Returning filling in excavated earth work including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and directed.
Removing surplus excavated soil to a distance not exceeding 50m, depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
Supply and laying dry sand laid in trenches as cable cushioning and covering complete all as specified and directed. Note : Punned thickness only will be measured and Paid
Supplying and laying un-reinforced precast concrete cable cover, class HV, type 1 with peak, size 300mm x 180mm x 40mm, complete all as specified and directed.
S&F in trenches /on wall in repairs GI tubing medium grade for road crossing and cable protection of the following sizes :-
80mm dia
100mm dia
Material and labour for providing new ACSR conductor including stringing through existing RCC poles, fixing in insulators, jumpers with polythene pipe, aluminium binding wire etc complete of different sizes including dismantling of existing old unserviceable ACSR of any size from any descritpion complete all as specified and directed. Note : Rates for new Aluminium cable terminal lugs are included in rate quoted.
S&F in replacement of Galvanaised Iron / Mild Steel cross arms channel, bracing, support, clamps etc fabricated structured steel, sections, including nuts, bolts, washers etc and cutting to required length beat to any shape drilling holes, fixed on poles or jointed by means of elect welding complete including painting with 2 coats of aluminum paint over a coat of red oxide primer after preparation of surfaces complete all as specified and directed.
S&F in replacement of Pin type porcelain vitreous, brown of white insulator suitable for 33 KV HT of working pressure of size 150 mm height, 150mm dia, including one galvanised mild steel spindle, two GI washer and one GI nut complete with mounting spindle complete all as specified and directed.
S&F in replacement of cable jointing kit for 11KV grade cable for Outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Aluminium conductor cable of size 120 to 185 sqmm complete all as specified and directed.
S&F in replacement of cable jointing kit for 11KV grade cable for Indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Aluminium conductor cable of size 120 to 185 sqmm complete all as specified and directed.
S&F in replacement of cable jointing kit for 11KV grade cable for Straight through joint heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Aluminium conductor cable of size 120 to 185sqmm complete all as specified and directed.
Supply, Laying, testing and commissioning in replacement of XLPE cable, PVC insulated, screened PVC bedded galvanised steel strip or wire armoured electric power cable, heavy duty with aluminium conductor 11000 Volts grade (earthed), 3 core 120 sqmm laid in trenches/ floor/ duct/ fixed on poles/ through GI tubing in different locations / areas complete all as specified and directed.
All as per item No 13 here in above but of cable size 3 core, 95 sqmm complete all as specified and directed.
S&F in replacement of Disc type porcelain vitreous, brown or white insulator suitable for 33 KV HT working Pressure of size 145mm height, 255 mm dia , including. one galvanised mild steel spindle, two GI washer and one GI nut complete with hardware fittings complete all as specified and directed.
S&F in replacement including testing and commissioning of (GOD) gang operated type air break isolating switch horizontal / vertical type type mounting complete, double break and operation rod of suitable length 400 amps capacity and suitable for 11 KV HT supply, complete all as specified and directed.
S&F in repairs single post insulator, 33 KV with mounting spindle etc. complete all as specified and directed.
Repairing/ Servicing the Air break isolating switch HT 33 KV 200/400 Amps by replacing the defective major spares including provn of minor bolts nuts etc complete all as specified and directed. Note :- Major spares will be measured & paid seperately under relevant items
Supply only 33 KV Airbreak switch spares complete all as specified and directed as under :-
Male contact / moving Contact Blade
Female contact / Fix Contact Jaw
Rotating contactor pipe 200A / 400 A
MS jumper carrier
Back Connector plate
S&F in replacement of drop out (DO) fuse unit expulsion type outdoor three pole 200 Amp suitable for HT 33 KV, comprising of insulators, steel base mounting frame, GI nut bolts etc with 30A, HT barrel type fuse complete all as specified and directed.
S&F in replacement including testing and commissioning of (GOD) gang operated type air break isolating switch horizontal/ vertical type type mounting complete, double break and operation rod of suitable length 400 amps with 09 Nos post insulators and suitable for 33 KV HT supply, complete all as specified and directed.
S&F in replacement of lightening arrestor Zinc oxide gap less type , station class suitable for 33 KV/ 10 KA complete with all fittings complete all as specified and directed.
S&F in replacement of lightening arrestors expulsion type complete with all fittings transmission class, discharge capacity 65 kilo amps, suitable for 11 KV complete all as specified and directed.
M&L preparation of old painted surfaces of HT 33 MRS at Manasbal consisting of Steel poles /chain link fencing, ISMBs, cross arms, GOD pipe,clamps etc., having of any description and applying one coat of aluminium paint manually complete all as specified and directed. Note : (a) This rate is inclusive of painting all minor items such as clamps, brackets, nuts, bolts and washers which is not particularly mentioned in this item. (b) This painting work will be carried out during Holidays only to avoid electric shut down.
M&L removing vegetation, grass, scrubs and bushes growing in Sub station yard along with fencing by manually / mechanically and keeping the sub station yard neat and clean complete all as specified and directed. Note :- Unit rate quoted shall be deemed to include to keep the installation neat and clean through out the period of contract and each cleaning will be measured and paid separately. Cutting of grass is month wise measured and paid separately.
M&L servicing of 33 KV VCB at MRS Manasbal, dismantling cleaning greasing the complete VCB with attached relays bus bar etc insulation testing, setting the contact gap by measuring as required, reassembling the VCB and reinstalling back to its original position checking and repairsing the current circuit panel wiring, relay testing and provision of minor spares as required complete including operational testing and commissoning complete all as specified and directed. Note : New major spare parts will be measured and paid under respective items.
M&L carrying out primary injection test of 33 KV Indoor / Outdoor type current transformer (Set of three)of VCB's by using standard injection test method& checking the electrical circuits for fault condition & proper functioning incl submitting test report complete all as specified and directed.
M&L primary injection test for 33 KV Potential transformer by applying low voltage on HV Side including testing of secondary wiring for its healthiness and submitting the test report complete all as specified and directed.
S&F in replacement including testing of metering and protection current transformer Oil filled out door type of 33 KV capacity ratio 100-50/5 or 200-100/5 class=5P, 10/1 15 VA complete all as specified and directed. Note : Calibration & testing records should be properly maintained complete all as specified and directed.
Disconnecting of all incoming and outgoing elect connections/earthing strips from defective/ repairable/ in service 33/11 KV step down outdoor type transformer of capacity 01 MVA oil cooled type from 33 KV Power Main Recieving Station at Manasbal, dehydration of oil, removing the radiator fins for the purpose of transportation, assembling it at new place, filling the transformer oil after filteration, shifting to workshop for repairs / rewinding purpose in a load carrier vehicle by using required capacity crane and bring back the same after repairs works and re-installation in the original position including testing, commissioning of 01 MVA transformers on site / area every month, connecting the all removed incoming and outgoing elect cable connections (include Buchloz relay, Oil Templerature Connection, Winding Temperature Connection and all tripping connections) complete all as specified and directed.
Dismantling of 33/11 KV, 01 MVA outdoor type step-down power transformer involves isolating and draining the transformer oil, followed by opening the top cover and carefully lifting the active core and copper winding assembly using a crane. The core and copper windings are dismantled by removing the clamping structures and carefully uncoiling the HT copper windings (primary side winding) of all three phases. The core tank, internal surfaces, and tap changer contacts are thoroughly cleaned using appropriate electrical cleaning agents. New HT and LT copper windings (primary and secondary both sides) are fabricated as per original design specifications using standard insulation materials, ensuring proper turns ratio and clearances. The copper windings are baked in a temperature-controlled oven to remove moisture and restore insulation resistance. After drying, the winding assembly is reassembled onto the core and placed back into the tank, followed by reinstallation of the top cover and associated components. Electrical tests such as balance test, voltage ratio test, insulation resistance (IR) test, and other functional checks are conducted to confirm operational reliability. Finally, the transformer is reassembled completely, refilled with filtered transformer oil under vacuum, and the work shall be carried out under the supervision of a qualified Engineer as under :-
Labour Charges (loading /unloading, fitting of HV / LV coils & assembling) complete all as specified and directed.
Detanking of whole transformer complete job including refitting back after repairs complete all as specified and directed.
Supply and fabrication of New HV copper conductor (DP Double paper insulator type) complete all as specified and directed.
Supply and fabrication of New LV copper conductor (DP Double paper Strip type) complete all as specified and directed.
Supply and Fabrication of 20 Paper Cover Copper wire for Tap Changer complete all as specified and directed.
New insulating press board complete all as specified and directed.
Complete Core Assembly complete all as specified and directed.
New EHV Grade transformer oil in litre complete all as specified and directed.
New gaskets RC 70 grade complete all as specified and directed.
Providing and installation of Phase separator with insulation between coil complete all as specified and directed.
Providing and installation of new transparent type silica gel breather complete all as specified and directed.
LV Bushing complete all as specified and directed.
HV bushing complete all as specified and directed.
LV metal Parts complete all as specified and directed.
HV metal parts complete all as specified and directed.
Miscellaneous items like insulating paper, cotton tap, weaving taps, SRBP tube, Sleeving, Gas, etc complete all as specified and directed.
Heat treatment (to be applied till desired values are achieved) complete all as specified and directed.
Hot oil bath of power transformer including flushing out of sludge, carbon deposits fron whole power transformer incl core conductor radiator transformer tank valves etc complete all as specified and directed.
Supply and fixing in replacement of winding temperature indicator (WTI) in 01 MVA Power Transformer with complete connections, testing and commissioning complete all as specified and directed.
Supply and fixing in replacement of oil temperature indicator (OTI) in 01 MVA Power Transformer with complete connections, testing and commissioning complete all as specified and directed.
Cleaning of Transformer surface of capacity 01 MVA for rusted area, preparing the surface and painting with same colour as earlier complete all as specified and directed.
Supply and filling of fresh transformer power oil of BDV not less than 50 KV for topping up of reduced level of transformer due to evaporation/ leakage/losses due to dehydration in HT 33 KV transformer/HT 11 KV AVR /Distribution transformer 100 to 500 KVA or for replacement complete including removing of old unservicable transformer oil complete all as specified and directed. Note : Necessary documents should be submitted by the contractor to GE.
Filteration of insulating oil with high pressure vaccum filteration plant, after filtration attains BDV upto 60 KV for Transformer, OCB and MOCB complete all as specified and directed. Note: Contractor shall change the filter assy before starting the filtration of Power / distribution transformer of any capacity in presence of Engineer-in-Charge.
Dismantling old and burnt out PT unit 33000/110/220 volts oil filled out door type taking out contact with lead and bushing from the bus bar and replacing by new one of same model suitable for 33 KV PT unit including testing on completion complete all as specified and directed.
Taking down carefully the existing 11KV/0.433 kV distribution transformer of capacity 100 KVA to 500 KVA by disconnecting HT overhead connection/underground cables and earth strips etc. from any substation / locations using suitable capacity of crane or by any other method irrespective of type of approach available, loading in vehicle, transportation to workshop for repairs and unloading carefully. Reloading the tranformer after repairs and testing of transformer; transportation to site and unloading including placing at given position and re-commissioning complete all as specified and directed. Note : All the T&P required for disonnection, connection, loading and loading including necessary petty items like bolts, nuts etc will be arranged by the contractor and rates for the same shall be deemed to be included in the rates quoted.
M&L repairs of Transformer step down 11 kV/0.433 KV any type of capacity 100 KVA to 500 KVA, after dismantling the transformer body carefully, opening the top cover of Transformer for inspection /repair, drain out the transformer oil from the tank complete, taking out the core and winding assy by disconnecting the internal connections, removing the carbon/sludge deposit in transformer housing core, renewal/replacement of unserviceable rubber bushes and washers, thimbles, replacement of silica gel, replacement of top cover gasket set including pasting with pasting material, replacement of worn out nut and bolts, replacement of unserviceable LT & HT bushes, cutting the burnt out winding and re-winding the same with suitable size of super enamelled copper wire as per existing guage, insulating the winding connection by using fire proof sleeve and fire proof tape, warnishing the coil, keeping the coils in electric oven chamber for 24 hrs to remove the moisture, Painting of complete transformer body from outside and inside by weather proof type using spray gun, Marking of MES/SM Number etc, replacement of conservator tank glass, re-intalling the core and winding inside properly, making the all connection with suitable copper lugs, refilling of dehydrated transformer oil including dehydration, reinstalling the top cover after cleaning and painting of housing, conservator tank, expulsion vent etc, Meggering the LT and HT side of the Transformer and testing complete all as specified and directed. Note :- Winding wire including labour for making of coils and LT/HT bushes will be measured & paid seperately.
Supply and replacement of silica gel breather clear view type including first fill of good quality silica gel of capacity suitable for 100 KVA to 500 KVA transformer complete all as specified and directed.
Supply and fixing in replacement of the following spares for VCB 33 KV 800 A 750 MVA fault level 36V-26/2000 & VCB 11 KV 400 A 25 KA 250MVA, complete all as specified and directed.
Closing coil 24/30V DC
Tripping coil 24/30V DC
Antipumping device 24/30V DC
33 KV porcelain bushing for VCB Top
33 KV porcelain bushing for VCB bottom
Earth Fault and over current relay of L&T Model No MC31A 24-110V
Digital type power factor indicator meter
Digital type Voltmeter / Ammeter 96 x 96 mm size
LED type indicator lamp assembly
Spout incoming side
Spout outgoing side
Epoxy insulators bushings for incoming / out going cables / bus bar supports as per existng size of VCBs
Gear system assy complete with handle for charging / discharging of VCBs
Spring charging motor for VCBs
M&L servicing of 33 KV VCB / 11KV VCB / bus coupler by dismantling cleaning greasing the complete VCB with attached relays bus bar etc insulation testing, setting the contact gap by measuring as required reassembling the VCB and reinstalling back to its original position checking and repairing the current circuit panel wiring, replacement of new spares as required complete including operational testing and commissioning complete all as specified and directed. Note : New spares will be measured and paid separately under relavent item of this schedule
M&L carrying out primary & secondary injection test of 33 KV or 11 KV indoor /outdoor type current transformer (Set of three) of VCB's by using standard injection test method and checking the electrical circuits for fault condition, all relay testing and proper functioning incl submitting the test report all as specified and directed. Notes : (i) PIT/SIT for VCB will be carried out in 6 months intervals and each primary and secondary injection test will be measured and paid) complete all as specified and directed. (ii) Proper documents should be maintained by the contractor.
Taking out the existing HT AVR unit 11000 volts grade (Make : Andrew Yule brentford) carefully by dismantling all incoming & outgoing elect / mechanical connections lifting and transport to reputed work shop by means of using suitable tools & plants, opening the body of buck booster/AVR units find out the defects and Servicing, repair/removing incl replacing the defective spare parts and re-assembling complete all as specified and as directed. (De-hydration of oil / new winding will be measured and paid under relavent item of this schedule) The job involves the following :- (a) Dismantling & taking down carefully from plant room by disconnecting all electrical / mechanical connection from HT and LT side including transporting to work shop complete all as specified and directed. (b) Opening the body of the AVR/buck booster units complete, drain out the oil, lift the cover and coil assembly, checking the serveability state of spares such as moving carbon roller, windings, insulating oil, LT/HT elect connections, HT/LT bushings, HT/LT brass terminals, Tig & Tag connectors, chain rack, limit switch, bearings, couplings, motor, Micro processor based PCB card, CT/PT assy, Aux / Reverible contactors, Winding/Oil temp/Buchloz relays assy, earthing connections, copper strip, etc. and repair / replace the same of existing model/make and making fully serviceable state of AVR/Buck booster assy at site incl testing as per OEM specifications complete all as specified and directed. (c) Cleaning the core laminations assembly by oil complete, removing the carbon sediments / dust in the coil and core gently without making any damage to coil and core complete all as specified and directed. (d) Re-assembling all dismantled parts including provision of new gasket, nut, bolts, refilling with transformer oil and transporting back to original location including electric/mechanical connection testing and commissioning complete all as specified and directed.
S&F in replacement of moving carbon rollers of existing size and make suitable for 1000 KVA AVR Unit complete all as specified and directed.
S&F in replacement of Tie & Tac brass connector suitable for 1000 KVA AVR Unit complete all as specified and directed.
S&F in replacement of Chain rack (double) incl bearing complete all as specified and directed.
S&F in replacement of Limit switch suitable for 1000 KVA AVR Unit complete all as specified and directed.
S&F in replacement of SS coupling suitable for 1000 KVA AVR Unit complete all as specified and directed.
S&F in replacement of Chain assy suitable for 1000 KVA AVR Unit complete all as specified and directed.
S&F in replacement of Synchronous motor suitable for 1000 KVA AVR Unit complete all as specified and directed.
S&F in replacement of PCB card suitable for 1000 KVA AVR Unit complete all as specified and directed.
S&F in replacement of PT unit 11000/110 volts suitable for 1000 KVA buck booster Unit complete all as specified and directed.
S&F in replacement of Reversible Contactor 3 pole 800 Amps suitable for 1000 KVA AVR Unit complete all as specified and directed.
S&F in replacement of Winding temperature relay complete suitable for 1000 KVA AVR Unit complete all as specified and directed.
S&F in replacement of Oil temperature relay complete suitable for 1000 KVA AVR Unit complete all as specified and directed.
S&F in replacement of Buchloz relay assy complete suitable for 1000 KVA AVR Unit/Transformer complete all as specified and directed.
S&F in replacement of Copper strip of any size suitable for 1000 KVA AVR Unit complete all as specified and directed.
S&F in replacement of Connector Strip 16 way / 24 way suitable for 1000 KVA AVR Unit complete all as specified and directed.
S&F in replacement of Aux contactor suitable for 1000 KVA AVR Unit complete all as specified and directed.
Supply and fixing Roller and contactors of HT AVR 1000 KVA of any make and model complete all as specified and directed.
Supply and fixing carbon bush assemby with fiber glass carrier and contactors of HT AVR 1000 KVA of any make and model complete all as specified and directed.
Supply only insulating rescue hook 6 feet long, operatig voltage 33 KV min, to pull worker incase of shock to a safe area complete all as specified and directed.
M&L in repairs for rewinding of transformer 33 KV / 440 Volts of capacity step down out door / indoor type of 100 KVA, including dismantling, transport to workshop, opening the body assy, drain out the oil, removing the core coil assembly from transformer remove the weak / burnt out unserviceable HT / LT winding assembly rewinding with correct gauge super enamelled copper wire of suitable class including drying, baking etc complete re-assembling the primary and secondary coil in core, re-assembling the transformer complete refill with transformer oil, installation and commissioning in the existing position complete all as specified and directed. Note : Each winding of HV / LV limb side will be measured separately and paid individually
Supply and filling new silica gel, superior quality in the breather unit of transformer including taking out the old unserviceable one complete all as specified and directed.
M&L replacement of brass terminal rod with nuts,bolts washers & bushings suitable for HT side of the transformer of any make and capacity from 100 KVA to 300 KVA complete all as specified and directed.
All as per item No 67 above but LT side complete all as specified and directed.
M&L replacement of brass terminal rod with nuts,bolts washers & bushings suitable for HT side of the transformer of any make and capacity from 315 KVA to 500 KVA complete all as specified and directed.
All as per item 69 above but LT side complete all as specified and directed.
M&L Earthing complete with copper earth plate 60x60cmx3.15 mm thick electrode and 20x3mm copper strip as earthing lead burried directly in ground (Earth pit not less then 2.25 metres deep below ground level) with top edge of the plate not less then 1.5 metre below normal ground level, conneceted to GI strip 32x6mm as earth lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No.5 and incl earth work, PCC pit and CI cover, watering pipe 20mm dia light grade, funnel, wire mesh, charcoal dust, 40mm dia light grade protection pipe and salt etc and connected to earthing test point all as specified or directed and testing complete all as specified and directed.
Supply and fixing of battery charger 12Volts to 72Volts complete all as specified and directed.
Supply and fix of inverter battery 180 AH complete all as specified and directed.
Excavation for removing/checking of HT cable joint with draining out water in trenches including returning filling of existing soil, sand , PCC cable cover and making good disturbed surfaced complete all as specified and directed.
Demolition of cement concrete/road in ground floor and paving not exceeding 15cm thickness below or above ground level including removal of rubbish to a distance exceeding 1.50Km and not exceeding 5.00 Km etc complete all as specified and directed.
Plain Cement concrete C-1 (1:3:6) (using 20mm graded crushed stone aggregate) as in foundations and mass including necessary filling complete all as specified and direcetd.
Supply the hard core broken stone/ boulders of gauge not exceeding 63mm, deposited, spread and levelled in layers not exceeding 15cm thick, to a true surface at the places complete all as specified and directed.
Notes :- An amount of Rs. 282015.00 on account of Credit Schedule for Schedule 'A' Part-II shall be deducted from total quoted amount of BOQ to arrive at the contract sum.
CHINAR CONSTRUCTION TRADERS (BID ID -3488299)
M/S Noor Mohammad Shalla (BID ID -3487218)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.35 MB
PS81T.pdf
Tender Documents • 1.09 MB
BOQ_828038.xls
BOQ • 11.81 MB