| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹41.2 LAccepted-AOC | L1 | Accepted-AOC AOC | |
| 2 | L2₹45.0 L+₹2.1 L (4.91%)Rejected-Finance | L2 | Rejected-Finance Other than lowest quoted tenderer | |
| 3 | L3₹46.1 L+₹3.2 L (7.37%)Rejected-Finance | L3 | Rejected-Finance Other than lowest quoted tenderer | |
| 4 | L4₹46.5 L+₹3.6 L (8.43%)Rejected-Finance | L4 | Rejected-Finance Other than lowest quoted tenderer | |
| 5 | L5₹46.5 L+₹3.6 L (8.43%)Rejected-Finance 218 D 1A JYANTIPUR NEAR SHYAM PIPE FACTORY SULEM SARAI PRAYAGRAJ UP | PRAYAGRAJ | PRAYAGRAJ | UP | L5 | Rejected-Finance Other than lowest quoted tenderer |
Tender Value
Refer Docs
EMD Value
₹99,000
Closing Date
25 Jan 2021, 6:00 pmClosed
GE WEST ALLAHABAD
GE WEST NEW CANTT ALLAHABAD
REPAIR / MAINT OF SUMMER / WINTER APPLIANCES AND CEILING FANS AND PETTY REPAIRS OF E/M NATURE INCL INTERNAL ELECTRIFICATION AT COD CHHEOKI
2020_MES_371790_3
8924/E8
Open Tender
Miscellaneous Works
Item Rate
270 days
CHHEOKI
Please refer tender documents
7 documents required · 7 mandatory
₹500
GE WEST ALLAHABAD
₹99,000
Yes
19 Mar 2021
14 Jan 2021
30 Jan 2021
14 Jan 2021
25 Jan 2021
19 Jan 2021
Amount
Taking down carefully point wiring of any type complete for light, fan socket or power point with fittings & fixtures such as ceiling rose, electric fittings, holders, switches, sockets, regulators, wooden batten, surface conduit/casing caping/conceal etc. including accessories including making good disturbed surface to match the existing complete all as specified and directed.
M&L for point wiring with FRLS PVC insulated unsheathed stranded copper conductor cable 1.5 sqmm (nominal area) along with same size and type of wire as continuous earth wire connected to common earth dolly drawn in and including non metallic PVC casing and caping not less than 20mm wide med grade ISI marked complete with all fixing accessories including factory made pressed steel concealed terminal box of required size of 1.2mm thick duly painted with 3mm thick plastic laminated sheet top cover with brass screw and cup washers complete all as specified and directed for the following :- .
(a) One light/fan/bell point controlled by one switch.
(b) One point for socket outlet 5 amps on independent board but not below the switch board in same vertical plane.
(c) One point for socket outlet 5 amps on independent board but below the switch board in same vertical /horizontal plane.
(d) One point for socket outlet 5 amp same board.
(e) One 3 pin 15 Amp socket outlet point controlled by one switch using 2.5 sqmm copper conductor cable with continuous earth wire of 2.5 sqmm copper conductor on independent board.
M&L for point wiring with FRLS PVC insulated unsheathed stranded copper conductor cable 1.5 sqmm (nominal area) 1100 volts grade, along with one single run of same size and type of copper wire as continuous earth wire to common earth dolly drawn in and including non metallic PVC rigid, medium grade surface conduit with all fixing accessories of 20mm dia, using new MS sunk terminal boxes of thickness not less 1.2mm, new 3mm thick laminated sheet cover with brass screw and cup washers with all acessories and making good to disturbed surfaces complete all as specified and directed for the following :-
(a) One light/fan/bell point controlled by one switch.
(b) One point for socket outlet 5 amps on independent board but not below the switch board in same vertical plane.
(c) One point for socket outlet 5 amps on independent board but below the switch board in same vertical /horizontal plane.
(d) One point for socket outlet 5 amp same board.
(e) One 3 pin 15 Amp socket outlet point controlled by one switch using 2.5 sqmm copper conductor cable with continuous earth wire of 2.5 sqmm copper conductor on independent board.
M&L for point wiring with FRLS PVC insulated unsheathed stranded copper conductor cable 1.5 sqmm (nominal area) 1100 volts grade, along with one single run of same size and type of copper wire as continuous earth wire to common earth dolly drawn in and including non metallic PVC rigid, medium grade conceal conduit with all fixing accessories of 20mm dia, using new MS sunk terminal boxes of thickness not less 1.2mm, new 3mm thick laminated sheet cover with brass screw and cup washers with all acessories and making good to disturbed conceal surfaces complete all as specified and directed for the following :-
(a) One light/fan/bell point controlled by one switch.
(b) One point for socket outlet 5 amps on independent board but not below the switch board in same vertical plane.
(c) One point for socket outlet 5 amps on independent board but below the switch board in same vertical /horizontal plane.
(d) One point for socket outlet 5 amp same board.
(e) One 3 pin 15 Amp socket outlet point controlled by one switch using 2.5 sqmm copper conductor cable with continuous earth wire of 2.5 sqmm copper conductor on independent board.
S&F ceiling rose surface type bakelite 65x50mm three terminal complete all as specified and directed.
S&F angle/batten type holder insulated body with back plate suitable for light point complete all as specified and directed.
Supply & fixing lamp holder adopter, two pin, insulated bakelite body for proper connection to light fitting/fixture from light point complete all as specified and directed.
S&F fan regulator, 5 stepped, electronic type, single phase, 80 watt, socket size incl connection complete complete all as specified and directed.
S&F switch piano flush type, 6 amps, 230V AC,single pole, one way complete all as specified and directed.
S&F bell push piano flush type 5 amp, SP , 230V AC complete all as specified and directed.
S&F socket out let multipurpose suitable for 5 pin, 6 amp flush type complete all as specified and directed.
S&F call bell, ding dong type, AC, 230 V, single pole complete all as specified and directed.
S&F in replacement of sheet metal enclosure single pole and neutral enclosure with a two pin and earth plug and socket along with one MCB, single pole of current rating 25 amps, C series 240 volts AC complete all as specified and directed.
S&F in repair switch Semi modular flush type 10 amps, single pole, one way 230 volt complete all as specified and directed.
S&F in repair switch Semi modular flush type 20 amps, single pole, one way ,230 volt complete all as specified and directed.
S&F in repair bell push Semi modular flush type 10 amp 230 volt complete all as specified and directed.
S&F in repair socket Semi modular flush type suitable for 10 amp, 5 pin ,230 volt complete all as specified and directed.
S&F in repair socket Semi modular flush type suitable for 20 amp, 6 pin ,230 volt complete all as specified and directed.
S&F in repair fan regulator, Semi modular type, 5 stepped, electronic type, single phase 230 volt including connection complete all as specified and directed.
S&F in repair pressed steel terminal boxes made out of 1.2mm thick mild steel sheet, 60 mm deep including cutting on sheet and fixing existing switches, sockets, fan regulator, etc. alongwith 3mm thick plastic laminated sheet cover, fitted with cadmium plated screw washer and cutting/chasing as required in brick wall to recess the same including making good to disturbed surface with cement mortar ratio 1:4 and treated the surface with existing white/colour wash/distemper etc to match with existing surface complete all as specified and directed.
(i) 100 mm x 100 mm
(ii) 200 mm x 150 mm
(iii) 200 mm X 250 mm
Taking down carefully sub main wiring of any nos of wire and size with earth wire on wooden batten/surface conduit/casing caping complete with its all accessories complete all as specified and directed.
M&L for two single core (submain) FRLS PVC insulated cable with 2.5 sqmm nominal cross sectional area stranded copper conductor and one single core green PVC insulated 2.5 sqmm stranded copper conductor earth continuity cable drawn in and including non metallic, medium duty, rigid PVC conduit not less than 20 mm dia concealed in wall including all conduit and fixing accessories including cutting chases & making good to disturbed surfaces with cement mortar ratio of 1:4 and colour wash complete all as specified and directed.. Note :- (I) The cost for cutting, chases required shall deemed to be included in the quoted unit rate. (II) Two run of submain wire, one run of earth wire and one run of PVC conduit shall be measured one RM
M&L for two single core (submain) FRLS PVC insulated cable with 4 sqmm nominal cross sectional area stranded copper conductor and one single core green PVC insulated 4.0 sqmm stranded copper conductor earth continuity cable drawn in and including non metallic, medium duty, rigid PVC conduit not less than 20 mm dia concealed in wall including all conduit and fixing accessories including cutting chases & making good to disturbed surfaces with cement mortar ratio of 1:4 and colour wash complete all as specified and directed.. Note :- (I) The cost for cutting, chases required shall deemed to be included in the quoted unit rate. (II) Two run of submain wire, one run of earth wire and one run of PVC conduit shall be measured one RM
M&L for two single core (submain) FRLS PVC insulated cable with 6 sqmm nominal cross sectional area stranded copper conductor and one single core green PVC insulated 6 sqmm stranded copper conductor earth continuity cable drawn in and including non metallic, medium duty, rigid PVC conduit not less than 20 mm dia concealed in wall including all conduit and fixing accessories including cutting chases & making good to disturbed surfaces with cement mortar ratio of 1:4 and colour wash complete all as specified and directed.. Note :- (I) The cost for cutting, chases required shall deemed to be included in the quoted unit rate. (II) Two run of submain wire, one run of earth wire and one run of PVC conduit shall be measured one RM
M&L for two single core (submain) FRLS PVC insulated cable with 10 sqmm nominal cross sectional area stranded copper conductor and one single core green FRLS PVC insulated 10 sqmm stranded copper conductor earth continuity cable drawn in and including non metallic, medium duty, rigid PVC conduit not less than 25 mm dia concealed in wall including all conduit and fixing accessories including cutting chases & making good to disturbed surfaces with cement mortar ratio of 1:4 and colour wash complete all as specified and directed.. Note :- (I) The cost for cutting, chases required shall deemed to be included in the quoted unit rate. (II) Two run of submain wire, one run of earth wire and one run of PVC conduit shall be measured one RM
Taking down main switches fuse unit, MCB/Kit kat distribution board with steel enclosure along with MCB’s /Kit kat fuse of any amps/ways including wooden board or from steel board and making good disturbed surfaces complete all as specified and directed.
S&F sheet metal enclosure for MCB's 240 volt 4 way single pole and neutral with 200 amps rated busbar double door on wall with and including suitable flat iron clamps duly grouted/ fixed flush in the wall complete all as specified and directed.
S&F sheet metal enclosure for MCB's 240 volt 6 way single pole and neutral with 200 amps rated bus bar, double door on wall with and including suitable flat iron clamps duly grouted/ fixed flush in the wall complete all as specified and directed.
S&F sheet metal enclosure for MCB's 240 volt 8 way single pole and neutral with 200 amps rated busbar, double door on wall with and including suitable flat iron clamps duly grouted/ fixed flush in the wall complete all as specified and directed.
S&F MCB single pole, 6 to 32 amps rating, 240 volts, 'C' series, 10 KA breaking capacity & making connection complete all as specified and directed.
S&F MCB single pole & Neutral, 40 amps rating, 240 volts, 'C' series, 10 KA breaking capacity & making connection complete all as specified and directed.
S&F MCB single pole & neutral 63 amp, 240 volts, 'C' series, 10 KA breaking capacity & making connection complete all as specified and directed.
S&F in repair MCB tripple pole & neutral 63 amp, 415 volts, 'C' series, 10 KA breaking capacity & making connection complete all as specified and directed.
Taking down existing old /worn out tube/CFL/bulk head/sketch light fittings of indoor type fixed on wall of any type/size with its all accessories including lamp complete all as specified and directed.
Supply & fixing in repair surface /wall mounted light fitting in CRCA powder coated white housing with pre wired suitable for single T8 LED tube along with supply and fixing one number LED tube in polycarbonate housing of nominal wattage - 18 Watt, Lumen out put - 2100 Lm, Colour Temp - 6500 Kelvin, Size & Length - G13/ T8/ 4 Feet with integral/in built driver, having short circuit and surge protection including making connection with two core PVC insulated,Surge protection 3KVA, CRI >80 life 40000 hrs sheathed copper conductor cable of size 23/0.0076 complete all as specified and directed. Make - Philips/ Wipro/Crompton/Havells or as approved
Supply & fixing in repair energy efficient LED light of 10 Watt of length - 02 Feet long having minimum 1150 Lumen output, wide voltage protection range 140-270 Volt AC housed in extruded aluminum housing (enhances safety) with high quality polycarbonate diffuser including making connection with two core PVC insulated,Surge protection 3KV, CRI >80 life 40000 hrs sheathed copper conductor cable of size 23/0.0076 complete all as specified and directed. Make Philips /Wipro/Havells/CG or as approved
Supply & fixing energy efficient LED Bulkhead in high pressure die cast aluminium housing of system wattage - 6.5 Watt, lumen out put - 700 Lm, colour Temp - 6500 K having Ingress protection - IP 65 fpr dust, water & IK 08 for external impact complete all as specified and directed. Model - Vista of make - Philips or its equivalent in WIPRO/Havells/Crompton or as approved
S&F in replacement of worn out/old linear fluorescent tube of 36 watt with energy efficient/saving retrofit LED tube in polycarbonate housing of nominal wattage - 18 Watt, Lumen out put - 2100 Lm or above, Colour Temp - 6500 Kelvin, Size & Length - G13/T8/4 Feet, Operating Voltage - 230 Volt AC, THD ≤ 20 % with intergral/in built driver, having short circuit and Surge protection 3KV, CRI >80 life 40000 hrs other safety test as per IS 15885 Part 2/Sec 13 including making minor addition/alteration in existing circuit as required complete all as specified and directed. Make - Havells/Philips/Crompton/Wipro
Supply & fixing in replacement of worn out 36 watt FPL with retro fit linear LED PLL lamp with extruded plastic body and PC diffuser complete with inbuilt electronic driver of high efficacy of system wattage 18 Watt, Length - 419 mm, Lumen out put - 1800 Lm or above, Colour Temp - 6500 K suitable for installation in existing 2G11 lamp holders including minor aleration in existing circuit as required complete all as specified and directed. Make - Philips/Wipro/Crompton/Havells or as approved
S&F in replacement of existing worn out ceiling light with recessed mounted LED light luminaries of size 600 mm x 600 mm an independent Isolated, electronic LED driver (SMPS based constant current supply) housed in CRCA powder coated sheet of system wattage - 42 Watt, Lumen out put- 4000-4300 Lm, THD < 10%, PF > 0.9, having short circuit and surge protection with all connected accessories including making connection with three core PVC insulated, sheathed copper conductor cable of size 23/0.0076 complete all as specified and directed. LED Light Model -Venus neo Product Type - VENUS NEO LHEWDRP7PK1W042 of Make - Havells or as approved.
S&F in replacement of existing worn out spot light 7watt of 100mm dia with Recess mounted pressure die-cast aluminium luminaire in powder coated white finish in round profile with optimized heat sink for efficient heat dissipation and separate replaceable electronic driver complete with LEDs, in built electronic LED driver and accessories pre-wired up to terminal block including making connection complete all as specified and directed. Make - Havells Cat pt No: LHEBJNP5PZ1W007 its equivalent model in Philips/Crompton or as approved.
S&F in replacement of existing worn out spot light 10watt of 100mm dia with Recess mounted pressure die-cast aluminium luminaire in powder coated white finish in round profile with optimized heat sink for efficient heat dissipation and separate replaceable electronic driver complete with LEDs, in built electronic LED driver and accessories pre-wired up to terminal block including making connection complete all as specified and directed. Make - Havells Cat pt No: LHEBJNP6PZ1W010 its equivalent model in Philips/Crompton or as approved.
S&F in replacement of existing worn out spot light 15watt of 155mm dia with Recess mounted pressure die-cast aluminium luminaire in powder coated white finish in round profile with optimized heat sink for efficient heat dissipation and separate replaceable electronic driver complete with LEDs, in built electronic LED driver and accessories pre-wired up to terminal block including making connection complete all as specified and directed. Make - Havells Cat pt No: LHEBJNP5IN1W015 its equivalent model in Philips/Crompton or as approved.
M &L for Earthing complete with GI earth plate electrode 600x600x6mm thick buried directly in ground (Earth pit not less than 2.25M deep below normal ground level) with top edge of the plate not less than 1.5m below normal GL. Connected to galvanized earth lead wire 4mm dia by means of nut, bolt, check nut and washers including necessary excavation and earth work in soft/loose soil, GI protection pipe light grade 15mm bore for protecting the GI wire mesh funnel alternate layer of charcoal dust, and salt PCC pit 1:3:6 type C1 using 20mm graded stone aggregate and 50mm thick RCC 1:2:4 type BO using 20mm graded stone aggregate cover re-inforced with 8 mm dia MS TMT bars 80mm C/C both ways complete all as specified and shown in Electrical plate No.3 SSR part-1 and connected to the earth point and testing complete all as specified and directed.
M&L for rewinding of stator complete with super enameled copper winding wire of existing gauge/ weight of copper coil, quick varnishing, oiling, greasing insulating materials including replacement of worn out parts like unserviceable cotter pin, nut, screw, check nuts and bolts as required incl. cleaning of body, and testing of the following size of fans of any make complete all as specified and directed. Note - (A) Fans to be collected by the contractor at their own arrangement from AGE E/M store for repair/rewinding and to be deposited at same place after making serviceable duly tested. (B) Aditional spare parts as required to make the serviceable of same will be measured and paid separately under respective items of schedule here in below:-
Ceiling fan of 1200 mm sweep
Ceiling fan of 1400 mm sweep
Exhaust fan of 230 mm sweep
Exhaust fan of 300 mm sweep
Exhaust fan of 380 mm sweep
Exhaust fan of 450 mm sweep
Wall fan/cabin/Pedestal of 400 mm sweep
S&F in repair Ball bearing of ceiling/exhaust fan of any size of exactly similar as existing in fan complete all as specified and directed. (Make-NBC/SKF)
S&F in repair 'U' shape shackle clamp assembly made out of MS flat iron incl checknut, bolts, screws, washer, split pin, lock nut, rubber reel etc. suitable to the down rod pipe and connecting complete all as specified and directed.
S&F in repair Capacitor 2.5 Mfd, 440 Volt AC complete all as specified and directed. Make - Asian/Usha/Epcos of siemens /Havells or as approved by GE
S&F in repair Capacitor 3.15 Mfd, 440 Volt AC complete all as specified and directed. Make - Asian/Usha/Epcos of siemens /Havells or as approved by GE
S&F in repair PVC insulated, sheathed flexible copper conductor cable in three core of size 23/0.0076 from connector to the ceiling rose complete all as specified and directed.
S&F in repair Capacitor clip as per existing complete all as specified and directed.
S&F in repair Canopy for ceiling fan suitable for any sweep/make as required incl. screw complete all as specified and directed.
M&L for Spray painting of stained/rusted/corroded Ceiling fan/Exhaust fan complete body with one coats of synthetic enamel white/smoke gray paint incl writing of MES No over one coat of primer all as specified and directed.
S&F in replacement of MS louvers shutters on wall suitable for exhaust fan of following sizes incl. suitable size of nut, bolts & washer complete all as specified and directed.:-
300 mm sweep
450 mm sweep
M & L for servicing of ceiling fans at site, oiling, greasing and checking of fan hook for damage spilt pin, nut bolt, rubber reels and down rod including proving new split pin and replacement of damage nut bolt and down rod complete all as specified and directed. Note: (i) replacement of down rod measure and paid seperately in relevant items
S&F in replacement Mild steel 'Medium grade' 15mm dia pipe down rod of required length with making split, holes, cut etc at both end of pipe as required for hanging of C/fan incl. painting of rod with two coats of synthetic enamel white paint over one coat of primer along with U' shape shackle clamp assembly made out of MS flat iron incl checknut, bolts, screws, washer, split pin, lock nut, rubber reel complete all as specified and directed.
S&F in repair fan hook suitable for 40 mm dia pipe, made out of MS flat iron size 50x6 mm incl. suitablesize of nut, bolt & washer complete all as specified and directed.
Repair/maint of window type AC/split AC any capacity of any make by cleaning and servicing of serviceable parts replacement of wiring kit, knobs & unserviceable parts replacement of air filter made of jute and reassembling the serviceable spare parts etc and testing for smooth functioning and re installation at site or deposit in MES store yard after repair. [Notes : (a) spare parts shall be measured and paid separately under respective items. (b) Replacement of nuts, bolts and washers deemed to be included in unit rate. (c) Minor repair of chesis by brazing/welding work deemed to be included in unit rate.]
Removing burnt/defective sealed compressor unit of any make from any type of air conditioner window type 1.5 ton capacity by cutting of suction and discharge lines unscrewing the foundation nuts, bolts etc, supply amd fixing of new sealed compressor unit of suitable make as existing by connecting suction and discharge lines with gas welding/brazing work and tightening foundation nuts & bolts etc all as directed
All as per item No. 68 above but for 1.5 ton Split type Air conditioner [Notes : (a) Capillary, drier, copper tubing etc are inclusive in unit rate. (b) New compressors will be purchased from authorised dealer only. (c) Unserviceable compressor either cut open or sealed unit have to be replaced by new one
All as per Item No 68 above but for air conditioner window / split type 2 ton capacity
Repair to Air conditioner window type/Split type 1/1.5/2 ton capacity by testing the leakage in system by filling of Nitrogen gas upto 300 PSIG and repairing of leaking spot/joints with gas welding work, cleaning and flushing out the complete system with gas, supply and replacing of drier/filter, making the complete system leak proof, vacuuming the system and charging of gas as existing and testing etc complete all as specified and directed. (Note : Drier capillary and copper tubing are inclusive in unit rate)
S&F in replacement of blower Motor 1/5 or 1/6 HP 230V AC, 50 Hz suitable for Air conditioner window type 1.5 ton capacity blower motor complete all as specified and directed.
S&F in replacement of blower Motor 0.2/0.25 HP for Air conditioner split type 1.5 ton/2 ton complete and as directed and specified (Make - GE/Crompton/Polar)
M & L for repair to blower Motor 1/6 HP to 0.25 HP with super enamelled copper wire of existing size suitable for Air conditioner window type / split type complete all as specified and directed.
M& L for repair to PCB circuit in air conditioner split type all as specified and directed.
S&F in replacement of power contactor 240V AC, 50 Hz 16 - 25 Amps range (Make- L&T/Bhartiya cutler hamme)
Supply and fixed in replacement of power contactor 415V AC, 50 Hz 15 Amps (Make - L&T Type MK-I/BCH or as approved)
M&L for painting of chasis/body of AC with one coat of synthetic enamel paint by spray painting of approved make including preparation of surface and one coat of aluminium paint to outer cover complete all as specified and directed.
Supply only following spare parts for window type AC capacity 1.5/2 ton : -
Capacitor 4 mfd
Running capacitor 36 mfd AC
Starter capacitor 80/100 mfd
Relay any make and type as approved
Over load protector
Thermostat
Cooling coil
Filter pad made of Jute
Condensers coil
Wiring kit
Front Panel of window AC any make of 1.5/2TR
Blower
M&L for Stands for Discharge unit of Split type AC/ Desert cooler stand etc. as per requirement complete all as specified and directed.
S&F in replacement indoor unit of AC 1.5 ton capacity split type of approved make complete all as specified and directed. (Note-Old unit to be deposited in MES store yard)
Dismantling of electric connection and water connection of water cooler opening the condensor fan motor blade, electrical accessories and spare parts of system carefully servicing of serviceable parts replacement of unserviceable parts oiling of fan motor etc reassembling all spare parts incl rewiring of internal connection of water cooler, testing and commissioning complete all as specified. (Note : Worn out or unserviceable spare parts to be replaced shall be measured and paid separately as supply only under respective item.)
Removing burnt/defective sealed compressor unit of any make from water cooler cap 40 Ltrs/hr by cutting of suction and discharge lines and unscrewing the foundation nuts & bolts etc, supply and fixing new sealed compressor unit Make as existing or equivalent in kirloskar or tecumseh by tightening the foundatopn nuts and bolts and connecting suction and dischrage line with gas welding work etc complete. [Note:- (i) Cost of transportation shall be deemed to be included in the quoted rates. GI fitting damaged while taking out/fixing back water coolers shall be replaced by the contractor at his own cost. (ii) All new compressor shall be purchased from authorised dealer only. (iii) Capillary, drier, filter strainer are inclusive in unit rate. (iv) Old compressor either cut open or sealed have to replaced with new one.]
All as per item No 74 above but water cooler Cap 60 Ltrs/hr
All as per item No 74 above but water cooler cap 150 Ltrs/hr.
M&L for replacement of Rubber hose pipe of 20mm bore with clips for outlet tray of water cooler of length 1.5 Mtr long approx complete all as specified and directed.
M&L for replacement of PVC sheet rubber bedding and lock of top cover of water cooler by screwing/welding MS sheet of top cover complete all as specified and directed.
M&L for replacement of PVC connection rigid type 18” long 15mm bore, with adopter at both ends complete all as specified and directed.
M&L for making the system leak proof and charging of gas Freon 12/22 as required in water cooler of capacity 40/60 Ltr including replacement of drier and capacity tube and testing on load complete all as specified and directed.
All as per item No. 80 above but of capacity 120/150 ltrs.
M&L for scraping old painted surface of water cooler any capacity and painting with two coats of synthetic enameled paint including writing SM/MES No with black paint with minimum 25 mm size of letters as directed
M&L for replacement of old condenser fins with new, forced air-cooled including necessary brazing work for water cooler of any capacity including testing for leakage complete all as specified and directed.
S&F in replacement of condenser fan motor of cap 1/35 HP with fan blade all as directed
M&L for winding of condenser fan motor of cap upto 1/8 HP with super enamelled copper wire of existing size including replacement of bush and fan blade incl painting complete all as specified and directed.
S&F in replacement of push cock/lift cock brass chromium plated 15 mm bore complete all as specified and directed.
M&L for replacement of flexible PVC pipe of following sizes for the drainage of waste water of water coolers or concealing the copper tubing of split AC and condensed moisture of air conditions complete all as specified and directed.
40mm dia
50mm dia
60mm dia
Detection and rectification of leakage of storage tank of water cooler by brazing soldering/welding as required at site or work shop testing for leak proof complete all as specified and directed.. [Note : (a) Nipple adoptor if required deemed to be included in unit rate. (b) Push cock, float valve etc if required will be measured and paid separately. (c) Changing of rubber/plastic packing is incl in unit rate]
Taking out the drain tray with PVC pipe of water cooler, electroplating (chromium plating) of drain tray after repair by denting/painting and including replacement of new PVC pipe of suitable size and length and refixing back all as directed.
Supply only the following items for water cooler :-
Starting capacitor 60/80 mfd
Running capacitor 10 mfd
Thermostat
Relay over load kit
Relay
Over load protector 1022
Wiring kit
Strainer/filter drum type/pen type
Door gasket
Float valve 1/2" including assembly brass made.
M&L for opening unserviceable automatic voltage stabilizer for repair, detection of fault and its repair cleaning of serviceable parts, replacement/repair of unserviceable or worn out parts soldering of terminal connection and testing after repair, painting with one coat of synthetic enamel paint externally all as specified including sign writing "AGE E/M New Cantt" all as directed any make:-[Note: (a) Replacement of new parts/worn out parts in lieu of unserviceable/worn out parts shall be measured and paid separately.(b) The flexible 3 core cable, 40/.0076, 23/.0076, 70/.0076 to be provided at least 1.5 RM is included in unit rate.]
Capacity 5 KVA/4 KVA
Capacity 3 KVA.
Supply only the following spare parts suitable for automatic voltage stabilizer of any make and capacity :-
Volt meter (0-300 volts)
Control relay
IC controlled circuit for 5KVA/4 KVA
IC controlled circuit for 3 KVA
Control transformer
Low/high voltage cut off and TDR system
Main transformer for 5 KVA/4 KVA
Main transformer 3 KVA
3 pin plug top 16 amp make Anchor
M&L for rewinding of boost/buck transformer of stabilizer with copper wire of existing gauge and same number of turn with best quality insulating material including testing complete and refixing back electrically and mechanically all as directed and specified by Engr-in-Charge of following capacity :-
Capacity 5 KVA/4 KVA
Capacity 3 KVA
S&F in replacement of 5 KVA stabilizer 230 volts Single phase (Note-Old to be deposited in MES store yard). (Make : Blue star/Vinitec/Brentford/Automatic Electric)
Taking down existing geyser any capacity/ type after suitable disconnecting all electrical and water supply connection, removing geyser to E/M store, opening and dismantling the complete geyser, cleaning all serviceable parts completely including descaling the geyser, for replacing the defective/wornout parts, reassembling the geyser, testing for proper functioning, transporting to & refixingin original location i.e in the same in position, reconnecting the geyser with electricsupply and water supply line and testing complete all as specified and directed. Note :- (i) Parts/spares required for replacement shall be measured and paid separately. (ii) Unit rate quoted shall be deemed to include minor items i.e. nut bolts, screws, lugs etc .
S&F in repair Heating element Square, threaded/ screwed type 1500 watt ISI marked complete all as specified and directed. Make Theeta/ Bajaj/ Hot top/Daspass or equivalent as approved.
S&F in repair Heating element cup type 1500 watt (ISI marked) complete all as specified and directed. Make - Bajaj/ Dass Pass/ Threeta or equivalent approved.
S&F in repair Heating element threaded/screwed type 2000 watt (ISI marked) suitable marked complete all as specified and directed. Make - Bajaj/Theeta/Hot top/ Daspass or equivalent as approved.
S&F in repair Heating element cup type 3000 watt (ISI marked) complete all as specified and directed. Make - Bajaj/Theeta/Hot top/ Daspass or equivalent as approved.
S&F in repair Thermostat suitable for geyser range 20 degree to 80 degree (ISI marked) complete all as specified and directed. Make-Thermoking/TTE,Elcon/ Expo/ Antriksh or equivalent approved.
S&F in repair PVC connection cotton braided heavy duty with brass union/coupling of length 450 mm with rubber washer suitable for 15 mm pipe complete all as specified and directed. .
S&F in repair Hot water outlet connection made of chromium plated flexible tubing for 15 mm bore pipe complete all as specified and directed.
S&F in repair Indicator lamp assembly with bulb with long lead suitable for geysers round or square type as sample kept in GE’s office complete all as specified and directed. .
S&F in repair PVC insulated flexible wire three core 2.5 sqmm copper conductor heavy duty complete all as specified and directed. .
S&F in repair Apperture plate assembly suitable for 25 ltrs geyserscomplete all as specified and directed.
S&F in repair Apperture plate assembly uitable for 50 ltrs geysers complete all as specified and directed.
S&F in repair Inner copper tank made out of 0.8mm(min.) for 25 ltrs geyser complete all as specified and directed.
S&F in repair Outer body with red,green indicator and bottom cover as per existing size & shape of capacity 25 ltrs geyser complete all as specified and directed.
S&F in repair 3 pin 15 amp plug top complete all as specified and directed. Make Anchor or equivalent as approved
S&F in repair electronic sensor for thermal setting as per sample kept in GE’s office complete all as specified and directed. .
M&L for painting of geysers after scraping, cleaning and preparing surface for painting and painting with two coats of white enameled paint of approved make and sign writing MES No etc complete all as specified and directed for the following capacity :-.
25 Ltrs capacity
50 Ltrs capacity
Repair of leakage of inner tank 25/50 ltr capacity geyser by brazing/soldering, testing including cutting of nut, bolt as required with gas welding cutter and providing new nut, bolts, washers etc complete all as specified and directed.
S&F in repairs Chromium plated brass stop cock 15 mm bore, screwed down, high pressure with crutch or butterfly handle complete all as specified and directed.
S&F in repairs MCB DP 32 amp, 230 volt, AC , 10 KA with indication & enclosure complete all as specified and directed.
S&F in repairs mild steel foundation nuts, bolts & washers heavy duty for fixing of geyser including grouting in wall complete all as specified and directed. .
S&F in repair two pin and earth plug and socket sheet metal enclosure with one single pole MCB 20 amp rating, 240 volt, C' series, 10 KA breaking capacity complete all as specified and directed.
M&L for Non return valve verticletype screwed for both ends with 15mm bore GI pipe.complete all as specified and as directed.
S&F in repair fusible plug steel nut complete all as specified and directed.
S&F in repair Timmer suitable for Hevalls geyser (ISI marked) complete all as specified and directed.
Supply & fixing in repair pendant type lamp holder, PVC/Polycarbonate type with cord grip cap complete all as specified and directed.
Supply & fixing in repair lamp holder of base Cap G - 13 suitable for 20/36 Watt FTL complete all as specified and directed.
Supply & fixing in repair lamp holder of base cap 2 G-11 suitable for non retrofit 36 CFL complete all as specified and directed.
Supply & fixing in repair socket out let 6 pin, 16 Amps flush type complete all as specified and directed.
Supply & fixing in repair switch, single pole, one way, 16 Amps complete all as specified and directed.
Supply & fixing in repair FRLS PVC insulated, unsheathed flexible copper conductor wire of nominal size 0.75 Sqmm or 24/0.20, 1100 Volt grade, ISI marked complete all as specified and directed.
Supply & fixing in repair FRLS PVC insulated, unsheathed flexible copper conductor wire of nominal size 1.5 Sqmm or 22/0.30 or 48/0.20 or 30/0.25, 1100 Volt grade, ISI marked complete all as specified and directed.
Supply & fixing in repair FRLS PVC insulated, unsheathed flexible copper conductor wire of nominal size 2.5 Sqmm or 36/0.30 or 80/0.20 or 50/0.25 , 1100 Volt grade, ISI marked complete all as specified and directed.
Supply & fixing in repair FRLS PVC insulated, unsheathed flexible copper conductor wire of nominal size 4.0 Sqmm or 56/0.30 or 128/0.20, 1100 Volt grade, ISI marked complete all as specified and directed.
Supply & fixing in repair FRLS PVC insulated, unsheathed flexible copper conductor wire of nominal size 6.0 Sqmm or 84/0.30, 1100 Volt grade, ISI marked complete all as specified and directed.
Supply & fixing in repair FRLS PVC insulated, unsheathed flexible copper conductor wire of nominal size 10.0 Sqmm or 140/0.30, 1100 Volt grade, ISI marked complete all as specified and directed.
Supply & fixing in repair PVC insulated, unsheathed flexible twin twisted copper conductor wire of nominal size 23/0.0076 complete all as specified and directed.
Supply & fixing in repair PVC insulated, unsheathed flexible twin twisted copper conductor wire of nominal size 40/0.0076 complete all as specified and directed.
Supply & fixing PVC insulation tape of width - 18 mm, thickness - 0.125 mm in length of 25 mtr, ISI marked for proper insulation of joints in wire where as required or directed
S&F in replacement of worn out/old linear fluorescent tube of 28 watt with energy efficient/saving retrofit LED tube in transparent glass housing to provide glare free light distribution of nominal system wattage - 16 Watt, Lumen out put - 1800 Lm or above, Colour Temp - 6500 Kelvin, Size & Length - G5/T5/4 Feet, Operating Voltage range - 140 to 270 Volt AC, THD ≤ 15 % with intergral/in built electronic driver (SMPS based constant current supply) having short circuit and surge protection upto 2.5 KV and other safety test as per IS 15885 Part 2/Sec 13 including making minor addition/alteration in existing circuit as required complete all as specified and directed. Make - Havells/Philips/Wipro/Crompton
Supply and fixing in replacement of worn out wooden batten/PVC Conduit with Non Metallic Rigid PVC conduit of following size, ISI Marked, conforming to IS 9537 Part III, medium grade including all fittings like bends, elbow reducer, junction boxes, tee bell mouth all fixing accessories such as coupler lock, nuts, saddles pipe hooks etc complete in all respect as specified and directed.
i) 20 mm nominal dia
ii) 25 mm nominal dia
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .