Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.9 LAccepted-AOC LOONPURIA GAON AT ROAD PANITOLA PO PANITOLA 786183 DIST TINSUKIA ASSAM | TINSUKIA | ASSAM | 786183 | L1 | Accepted-AOC L1 BIDDER | |
| 2 | L2₹21.0 L+₹28,916.40 (1.40%)Rejected-Finance COLLEGE ROAD CHABUA PO CHABUA DIST DIBRUGARH ASSAM 786184 | DIBRUGARH | ASSAM | 786184 | L2 | Rejected-Finance HIGHER THAN L1 BIDDER | |
| 3 | L3₹25.7 L+₹5.0 L (24.0%)Rejected-Finance AT MAIN ROAD DANDAI PO PS DANDAI DIST GARHWA | LATEHAR | JHARKHAND | 822112 | L3 | Rejected-Finance HIGHER THAN L1 BIDDER |
Tender Value
₹23.6 L
EMD Value
₹47,300
Closing Date
21 Jun 2021, 6:00 pmClosed
MAJ JP SAHOO
GE 872 EWS, C/O 99 APO
SPECIAL REPAIRS TO LT PANELS OH LINES CONCRETE POLES AND REPLACEMENT OF T-5 HPSV STREET LIGHTS WITH ENERGY EFFICIENT LED FITTINGS AT NLP MIL STN AND SPECIAL REPAIRS TO STEEL TUBULAR POLES RELOCATION OF RCC STEEL POLES OH LINES ALLIED WKS AT ZONE
2021_MES_438734_2
8605/T-05/E8
Open Tender
Miscellaneous Works
Item Rate
183 days
LIKABALI
All as per NIT and Tender documents
7 documents required · 7 mandatory
₹500
GE 872 EWS
₹47,300
Yes
23 Jun 2021
31 May 2021
22 Jun 2021
31 May 2021
21 Jun 2021
9 Jun 2021
31 May 2021 - 3 Jun 2021
Amount
Dismantling Unserviceable LT Electric Pole (Pre-stressed RCC/ Steel Tubular) of any description and any size including Demolition Cement Concrete (if required on Ground) and Made Good disturbed Ground, complete all as specified and as directed. NOTE : Unserviceable Pole will be dismantled at Ground Level and disturbed Ground will Made Good as directed for which Earthwork, Demolition Cement Concrete, etc. will not be Measured and Paid separately.
Dismantling Cross Arms, Mild Steel Channel, Angle Section, Flat Iron, Mild Steel Rod, etc., complete all as specified and as directed.
Taking down unserviceable Insulator of any description and from any Situation, complete all as specified and as directed.
Taking down ACSR Conductor of any size including Line Spacers of OH Electric Lines from LT Electric Poles, complete all as specified and as directed.
Taking down Unserviceable/ Rusted GI Earth Wire, Cradles Guards of any size from LT Electric Poles of any size and capacity, complete all as specified and as directed.
Dismantling Stay Assembly complete of any description, complete all as specified and as directed. NOTE : Unserviceable Stay Assembly will be dismantled at Ground Level and disturbed Ground will Made Good as directed for which Earth Works, Demolition of Cement Concrete, etc. will not be Measured & Paid separately.
Taking down Unserviceable Street Light Fitting of any description from any Height and from any Situation, complete all as specified and as directed.
Disconnecting & Taking down/out unserviceable LT Cable of any size and any description from Trenches, Floors, Walls, GI Pipes, etc. incuding Bricks/Cable Protection Cover, Pipes, etc., complete all as specified and as directed. NOTE : Necessary Earth Works will be Measured & Paid under appropriate Items.
Excavating in Trenches, not exc. 1.50 Metre Wide and Depth not exc. 1.50 Metre for Taking out/up and Laying of Cable, Electric Pole, etc., Forming Surfaces to required Foundation, etc. and getting out as in Soft/Loose Soil, complete all as specified and as directed.
Excavating in Trenches, not exc. 1.50 Metre Wide and Depth exc. 1.50 Metre but not exc. 3.00 Metre for Electric Pole, etc., Forming Surfaces to required Foundation, etc. and getting out as in Soft/Loose Soil, complete all as specified and as directed.
Returning, Filling in including Spreading, Levelling, Watering, Well Ramming in Layers not exc. 25 Cm, Providing Heaps along the Route of the Cable Line with Surplus Soil in Soft/Loose Soil, complete all as specified and as directed.
Removing excavated Materials (Soils) not exc. 50.00 Metre and depositing where directed at a level not exc. 1.50 Metre above the Starting Point in Soil, complete all as specified and as directed.
M&L Steel Tubular Swaged Pole Type 410 SP-31 (9.0 Metre long) complete with Mild Steel Base Plate, Finial Taper Plug, Bolts, Nuts & Screws, etc. as specified including One coat Aluminium Paint over One Coat of Red Oxide Zinc Chrome Primer, Providing 5 No. Band/ Strap with Paint Black/ Yellow Colour 300mm apart from Plinth Block and numbering of Pole/ Painting embedded portion of Pole with One coat of Bituminous Paint, complete all as specified and as directed. NOTE : Necessary Earth Work & PCC will be Measured and Paid separately under relevent Items.
M&L Cross Arms, Bracings, Supports, Clamps and Back Plates, fabricated from Structural Steel Sections including Nuts, Bolts, Washers, etc., welding, bending cold or hot, drilling holes for Bolts, in any shape or size as indicated or directed and applying Two coats of Aluminium Paint over a coat of Red Oxide Zinc Chromium Primer after preparation of Surfaces, complete all as specified and as directed.
S&F Insulator Pin type, 100mm height, 65mm dia for 1100 Volt grade, Porcelain, Vitreous, white, brown or green including One Galvanised Mild Steel Spindle Two Galvanised Iron Washer and One Galvanised Iron Nut, complete all as specified and as directed.
S&F Insulator Shackle type, Porcelain, Vitreious, white brown or green of size 100mm High & 115mm dia including Galvanised Mild Steel Straps of Section 31x5.0mm, 14mm dia Insulator Bolts, Nuts, Washer, etc. for Working Pressure 1100 Volt grade, complete all as specified and as directed.
M&L ACSR Conductor of any size for LT Over Head Line including Stringing Conductor fixed on Poles and binding with Aluminium Binding Wire, etc., complete all as specified and as directed. NOTE : Sizes of Conductor will be as per Site requirement as directed by Engineer-in-Charge.
M&L Restretching, Tightening & Fixing of ACSR Conductor of any size on LT Electric Poles including necessary Aluminium Binding Wire, Connectors, PVC Sleeves for Jumper, etc. complete all as specified and as directed. NOTE : Cost of Aluminium Binding Wire (as per Site requirement/as directed by Engineer-in-Charge) will deemed to be included in the Quoted Unit Rate.
M&L Galvanised Iron Wire 3.15/4.0mm dia as Continuous Earth Wire, Guards and Cradles (Hexagonal/ Rectangular), etc. and binding with and including GI Binding Wire 1.6mm dia, complete all as specified and as directed.
M&L Stay Assembly complete with all Accessories such as Mild Steel Flat Iron Stay Clamp of suitable size, Galvanised Stay Wire 7/3.15mm stranded, One Loop Insulator, Porcelain Vitreous (White, Brown or Green) Overall Dimensions 65x90mm and Clearance of Hole 16mm, Stay Grips, Mild Steel Galvanised Stay Bow, suitable size Thimbles Galvanised Steel and 16mm dia Stay Rod of Mild Steel Galvanised and Mild Steel Galvanised Stay Plate of size 230x230x6.0mm all as shown in Electrical Plate No. 1 of MES Schedule Part-I, complete all as specified and as directed. NOTE : Necessary Earth Work, Cement Concrete, etc. will be Measured and Paid separately under relevant Items.
S&F Danger Notice Plate of 1.6mm thick Mild Steel Sheet for LT, 25x20 Cm size, Vitreous Enamelled White, with Letters, Figures and Conventional Skull and Bones in Signal Red Colour and fixed with Mild Steel Clamps, Bolts & Nuts of approved size including Taking down unserviceable Danger Notice Plate of any description and from any Situation, complete all as specified and as directed.
M&L Cement Concrete 1:4:8 (40mm graded stone aggregate) in Foundation, Filling and Mass Concrete, etc. including Use and Waste of Formwork as required/ordered, complete all as specified and as directed.
M&L Cement Concrete 1:3:6 (40mm graded stone aggregate) in Foundation, Filling and Mass Concrete, etc. including Use and Waste of Formwork as required/ordered, complete all as specified and as directed.
M&L Cement Concrete 1:2:4 (20mm graded stone aggregate) in Copping of Electric Poles, etc, weathering slightly rounded or chamfered angle and throating, finishing all Exposed Faces of Concrete including necessary Formwork, complete all as specified and as directed.
S&F LED Street Light Fitting 45 Watt, New Generation, Environmental Friendly, Energy Saving, Long Life, made up of Pressure Die-cast Aluminium Housing with High Power LEDs as Lighting Source and Lens embeded PC Cover having Top Opening, with separate Driver Compartment, IP-66 protected, Impact Resistance of IK-07, Providing Electric Connections, complete all as specified and as directed. MAKE : BAJAJ/ CG/ C&S/ HAVELLS/ PHILIPS
S&F LED Street Light Fitting 48 Watt, New Generation, Environmental Friendly, Energy Saving, Long Life, made up of Pressure Die-cast Aluminium Housing with High Power LEDs as Lighting Source and Lens embeded PC Cover having Top Opening, with separate Driver Compartment, IP-66 protected, Impact Resistance of IK-07, Providing Electric Connections, complete all as specified and as directed. MAKE : BAJAJ/ CG/ C&S/ HAVELLS/ PHILIPS
M&L Street Light Fitting Bracket suitable for Street Light Fitting 45/48 Watt, made out from GI Pipe 32/40mm Bore (dia), Light Grade, not exc. 1.20 Metre long, bend to required shape and fixing to Poles, etc. with and including Mild Steel Flat Iron Clamps 40x5mm of suitable Length, 2 No. Nuts, Bolts, Washers, etc. including Painting with One coat of Red Oxide Zinc Chrome Primer and Two coats of Aluminium Paint to all Mild Steel Works including Taking down Unserviceable Street Light Fitting Bracket of any description from any Height, complete all as specified and as directed.
M&L Taking down Street Light Fitting of any type and any capacity from any Height after disconnecting, Opening Cover and Checking of Light Fitting, Repairing as required, Re-fixing the Light Fitting after repaired in Original Position and Providing Connections including Replacing Defective/ Unserviceable Spares/ Parts, complete all as specified and as directed. NOTE : New Drivers (Quantites are Provisional) will be Measured and Paid separately under respective Items as 'Supply only'.
Supply only Driver (as approved) suitable for LED Street Light Fitting 30 Watt, complete all as specified and as directed.
Supply only Driver (as approved) suitable for LED Street Light Fitting 45 Watt, complete all as specified and as directed.
Supply only Driver (as approved) suitable for LED Street Light Fitting 100 Watt, complete all as specified and as directed.
S&F FRP Looping Box of size 225x295x122mm suitable for Cable Junction Boxes, IP-66/67 Protected, Weather Proof for Outdoor Installation (with Knock Outs for Cable Entry) and suitable for Cable 16/35 Sqmm LT XLPE Armoured Cable including suitable size Flat Iron 40x3mm Clamps with Mild Steel Bolts, Nuts & Washers, etc. including Taking down unserviceable Box from any Situations, complete all as specified and as directed. MAKE : HENSEL/ SCHNEIDER/ SINTEX/ UNIVERSAL SWITCH GEARS CONTROL (as approved by GE)
M&L XLPE insulated, armoured heavy duty, Electric Cable with Aluminium Conductor, 1100 Volt grade, Cross-sectional area 6.0 Sqmm, 4 Core, laid in Trenches/Ducts or Passing through Pipes or Fixing on Poles, etc., complete all as specified and as directed. NOTE : Necessary Earth works, Sand cushioning, Cable Protection Cover & GI Pipe, etc. will be Measured and Paid separately under relevent Items.
M&L XLPE insulated, armoured heavy duty, Electric Cable with Aluminium Conductor, 1100 Volt grade, Cross-sectional area 10 Sqmm, 4 Core, laid in Trenches/Ducts or Passing through Pipes or Fixing on Poles, etc., complete all as specified and as directed. NOTE : Necessary Earth works, Sand cushioning, Cable Protection Cover & GI Pipe, etc. will be Measured and Paid separately under relevent Items.
M&L XLPE insulated, armoured heavy duty, Electric Cable with Aluminium Conductor, 1100 Volt grade, Cross-sectional area 16 Sqmm, 4 Core, laid in Trenches/Ducts or Passing through Pipes or Fixing on Poles, etc., complete all as specified and as directed. NOTE : Necessary Earth works, Sand cushioning, Cable Protection Cover & GI Pipe, etc. will be Measured and Paid separately under relevent Items.
M&L XLPE insulated, armoured heavy duty, Electric Cable with Aluminium Conductor, 1100 Volt grade, Cross-sectional area 35 Sqmm, 3½ Core, laid in Trenches/Ducts or Passing through Pipes or Fixing on Poles, etc., complete all as specified and as directed. NOTE : Necessary Earth works, Sand cushioning, Cable Protection Cover & GI Pipe, etc. will be Measured and Paid separately under relevent Items.
M&L Sand Cushioning (dry) in Trenches/Ducts for protection of UG Cables (below, above and around the UG Cable laid) of 23 Cm Spread thickness (8 Cm in depth before laying the Cable and 15 Cm in depth after laying the Cable) and consolidated (punned) upto 180mm thickness, complete all as specified and as directed. NOTE : For the purpose of Payment, Punned thickness of Sand Cushioning only will be Measured.
Supply & Laying Sub-class ‘B’ Bricks, Kiln burnt as Mechnical Protection to Cable with Width Equal to Length of Brick, complete all as specified and as directed.
M&L Galvanised Steel Tubing Pipe 40mm bore (dia), light grade with Bend, laid in Trenches or under Roads/ Flooring/ Culverts and/or fixing to Electric Poles with suitable size Mild Steel Flat Iron Clamps, Bolts, Nuts, Washers, etc., complete all as specified and as directed.
M&L Galvanised Steel Tubing Pipe 50mm bore (dia), light grade with Bend, laid in Trenches or under Roads/ Flooring/ Culverts and/or fixing to Electric Poles with suitable size Mild Steel Flat Iron Clamps, Bolts, Nuts, Washers, etc., complete all as specified and as directed.
M&L Galvanised Steel Tubing Pipe 80mm bore (dia), light grade with Bend, laid in Trenches or under Roads/ Flooring/ Culverts and/or fixing to Electric Poles with suitable size Mild Steel Flat Iron Clamps, Bolts, Nuts, Washers, etc., complete all as specified and as directed.
M&L Feeder Pillar Box, made out of 16 SWG CRCA Sheet, Double Doors, Powder coated Weather Proof and mounting on 40x40x6.0mm Mild Steel Angle Iron Frame, Out Door type, Front Opening Shutter with proper Locking Arrangements, complete with Fixing Arrangements with Mild Steel Nuts, Bolts for grouting as required at Site including Taking down unserviceable/rusted LT Panel/ Feeder Pillar Box, comprising of with the followings :- (a) Aluminium Bus-bar 4 Strip 100 Amp - 01 Set (b) MCCB 100 Amp, 36 kA, 430 Volt (I/C) - 01 No. (c) MCCB 100 Amp, 36 kA, 430 Volt (OG) - 01 No. (d) MCB 63 Amp, SPN - 08 No.
M&L Earthing complete with Galvanised Steel Pipe Electrode, 40mm bore (dia), Medium grade, 2.50 Metre length, buried directly and preferably Vertically in ground with Top Edge not less than 1.25 Metre below Ground Level connected with Earthing Lead of 4.0mm dia Galvanised Iron or Steel Wire by means of Bolts, Nuts, Check, Nuts and Washers of Galvanised Iron or Steel and Earth Wire protected with and including GI Pipe 15mm bore (dia) Light grade, connected to Test Point upto 7.50 Metre away from Earth Electrode situated, Earth Plate surrounded by a packed thickness of Char Coal or Coke Dust mixed with Common Salt in alternate layers of not exc.150mm thick, PCC Pit in Cement Concrete 1:3:6 (20mm graded stone aggregate) and Pre-cast RCC Cover Slab of size 350x350x50mm in Cement Concrete 1:2:4 (20mm graded stone aggregate), reinforced with 10mm dia TMT Bars @ 100mm Centre to Centre in both ways, GI Wire Mesh, PGI Funnel with GI Watering Pipe 20mm bore (dia) Medium grade including necessary Excavation in Soft/ Loose Soil, Returning, Filling in and Removal of surplus Spoil upto a distance of 50.00 Metre and all as shown in Electrical Plate No. 2 of MES Schedule Part-I and Testing on Completion including Taking down/out Unserviceable Earthing of any description, complete all as per specified and as directed.
M&L Earthing with Galvanised Earth Plate Electrode 600x600x6.0mm thick, buried directly in Ground vertically to a depth not less than 2.25 Metre below Ground Level with Top Edge of Earth Plate at depth not less than 1.50 Metre below normal Ground Level, connected to Galvanised Earth Lead Wire 4.0mm dia by means of Bolts, Nuts, Check, Nuts and Washers of Galvanised Iron or Steel and Earth Wire protected with and including GI Pipe 15mm bore (dia) Light grade, connected to Test Point upto 7.50 Metre away from Earth Electrode situated, Earth Plate surrounded by a packed thickness of Char Coal or Coke Dust mixed with Common Salt in alternate layers of not exc.150mm thick, PCC Pit in Cement Concrete 1:3:6 (20mm graded stone aggregate) and Pre-cast RCC Cover Slab of size 350x350x50mm in Cement Concrete 1:2:4 (20mm graded stone aggregate), reinforced with 10mm dia TMT Bars @ 100mm Centre to Centre in both ways, GI Wire Mesh, PGI Funnel with GI Watering Pipe 20mm bore (dia) Medium grade including necessary Excavation in Soft/ Loose Soil, Returning, Filling in and Removal of surplus Spoil upto a distance of 50.00 Metre and all as shown in Electrical Plate No. 3 of MES Schedule Part-I and Testing on Completion including Taking down/out Unserviceable Earthing of any description, complete all as per specified and as directed.
M/s PRABIR ENTERPRISE
ms singh construction
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .