Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.7 LAccepted-Finance | ₹25.7 L | L1 | Accepted-Finance Due to lowest bid price |
| 2 | L2₹26.5 LRejected-Finance | ₹26.5 L | L2 | Rejected-Finance Due to high bid price |
| 3 | L3₹26.9 LRejected-Finance CHATTHA SEKHAWAN ROAD SUNAM DISTT SANGRUR | SUNAM | SANGRUR | PUNJAB | ₹26.9 L | L3 | Rejected-Finance Due to high bid price |
| 4 | L4₹28.8 LRejected-Finance | ₹28.8 L | L4 | Rejected-Finance Due to high bid price |
Tender Value
₹34.4 L
EMD Value
₹68,000
Closing Date
27 Jan 2026, 12:00 pmClosed
Executive Engineer
Provincial Division PWD BandR DAC Complex Sangrur
Construction of Room with Varanda for Gym in Jaid Patti, Longowal, Distt. Sangrur (Punjab)
2026_CEPW_157925_1
Bid No 83 Dt. 14-01-2026
Open Tender
Civil Works - Buildings
90 days
Sangrur
Please refer Tender documents.
6 documents required · 6 mandatory
₹5,000
₹68,000
Yes
2 Feb 2026
15 Jan 2026
27 Jan 2026
15 Jan 2026
27 Jan 2026
15 Jan 2026
CONSTRUCTION OF MAIN BUILDING :- Earth work in excavation in foundations, trenches etc. in all kinds of soil where pick jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation and subsequent filling around masonry in 15 cm. layers with compaction including disposal of all surplus soil as directed within a lead of 30 metres.
Boring, providing and installing bored cast-insitu reinforced cement concrete pile of specified diameter and length below the pile cap to carry a safe working load not less than specified, excluding the cost of concrete and steel reinforcement (The rates of concrete and steel reinforcement are to be taken for respective item of chapter No.10 & 18 respectively) but including the cost of boring with manual auger (without bentonite solution) and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. all complete as per BIS specifications/ codes, including removal of excavated earth with all lifts and leads (Length of pile for payment shall be measured upto bottom of pile cap) 450 mm Dia pile
Cement concrete 1:5:10 with 40 mm gauge stone ballast. using concrete mixing volumetric type
Reinforced cement concrete M-25 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth..
Shuttering for faces of concrete foundations and foundation beam & plinth beam (vertical or battering)
First class burnt brick work laid in cement sand mortar 1:6 in foundation and plinth.
Reinforced cement concrete M-25 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in superstructure.
Centring and shuttering for Columns ( Square or Rectangular or plygonal in plain) in superstructure
Centring and shuttering for sides and soffits of beam, beams launchingsgirders bressumers, lintels
Centring and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc.
Cold twisted deformed (Ribbed/ Tor Steel Bar/TMT) Bars Fe 500 grade as per IS 1786-2008, for R.C.C works, where not including in the complete rate of RCC including bending and placing in position complete
First class burnt brick work laid in cement sand mortar 1:5 in first storey upto 4 metres above plinth level.
Extra rate for First Floor
Dressed or moulded two brick cornice laid in cement sand mortar 1:4 including 12.5mm thick cement plaster 1:4 or pointing as required
12.5 mm thick cement plaster 1:5
20mm thick cement plaster 1:5 in two coat work
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes (working pressure 4 kgf / cm²) conforming to IS : 4985, including fixing with MS Clamp U-PVC pipes (working pressure 4kgf. / sqcm) pipe 110 mm dia.
Providing and fixing 110 mm dia. U.P.V.C bend for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge. UPVC 110 mm bend
Providing and fixing 110 mm dia SWR U.P.V.C Coupling/Sockete for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge.
Top khurra 0.6m x 0.6m for rain water pipe in 25mm thick cement concrete 1:2:4 over 50mm thick cement concrete 1:8:16.
Providing and fixing in position gratings 150mmx150mm for gully trap. PVC grating
Bottom Khurra on ground 1.2m. x 0.6m. consisting of brick on-edge laid in cement mortar 1:3 over 75mm cement concrete 1:8:16 including 12.5m.m. thick cement plaster 1:3.
Terracing consiting of tiles 22.86x11.43x3.83cm laid over 25 mm mud plaster 7.5 cm mud filling on another layer of 25mm mud plaster including two coats of bitumen laid hot at 1.65 Kg. /Sqm top of R.C.C. slab including grouting with cement sand mortar 1:4 and top surface to be left clean after wire brushing
Cement concrete 1:2:4 gola 10cm x 10cm concave quadrant along junction of roofs with parapet wall finished smooth, where specially specified.
Earth filling under floors with surplus ordinary soil or soil containing gravel or kankar upto 40% excavated from outside the building plinth in 15 cm layers including ramming, watering and consolidating lead upto 30 metres
Earth filling under floors with surplus ordinary soil or soil containing gravel or kankar upto 40% excavated from foundation and taken only from outside the building plinth in 15 cm layers including ramming, watering and consolidating lead upto 30 metres.
Base course of floor consisting of 100mm thick cement concrete 1:8:16 and 100mm sand filling using mechanical mixer for mixing of material
Providing and laying vitrified floor tiles in different sizes in light colour shades made using Full Body Technology (thickness to be specified by the manufacturer) with water absorption’s less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 fine sand), complete. ( Full body vitrified tiles have pigment in entire body / thickness of tile which makes chips and scratches less noticeable and make na ideal choice for high traffic zones.) size 600 x 600 mm
Grouting the joints of flooring tiles having joints of 3 mm width, using 2mm to 3 mm gap using spacers and later this gap to be filled with cement based grout ) with Cement base grout and matching pigments etc., complete, including filling / grouting and finishing complete as per direction of Engineer-in-charge. Size Size 1000x1000 mm.
Marble stone flooring with 18-20 mm thick marble stone, as per sample of marble approved by Engineer-in-charge, over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry, including rubbing and polishing complete with : Udaipur Green Marble Tiles of thickness 18mm to 20mm Slabs sizes above 0.50 sqm
Supplying Pressed steel sheet frames (chowkhat) consisting of 18gauge (1.25 mm thick steel sheet of the specified section, including iron lugs (hold fast) iron hinges conforming to PWD specification including bolts for fixing stops lock notch provision for receiving tower bolts and finished with 1 primer coat approved quality, fixed in position excluding the cost of cement concrete 1:3:6 for fillings in the frame and cement concrete 1:2:4 for lugs complete. Doors and windows frame of size 151mm x 60mm with 35 mm wide double rebate weighing 3.95 kg per meter.
Providing & fixing of Box type steel windows, made of various ERW section outer 60mm x 25mm, central mullion 60mm x 25mm, for shutter 50mm x 20mm having thickness of 1.25mm (18 gauge), shash bar MS Tee 25mm x 3mm where required joints mitered and electrically flashwelded, with iron fittings including necessary iron handles, hinged cleat, tower bolts, iron hold fast and pintle hinges complete (excluding glazing and wire gauge) and finished with ready mixed paint red lead non setting primer complete as per specification, Drawings and to the entire satisfaction of engineer-in-charge. (Note:- Glazing, wire gauge and grill will be paid as per respective items)
Wire gauge fixed in steel windows, of standard rolled steel section with 3mm thick flat iron cover moulding of 12.5 mm width, fixed with machine screws, complete in all respects.
Providing & Fixing glass panes with nails and putty or wooden strip complete in all respect. Glazing area above 0.09 sqm 5.0mm thick Plate glass (INDIAN)
Wrought iron & Mild steel ladders, framed grills, gratings etc. with ends of bars riveted or molded forged framed window guards, barred iron doors stair case iron railing etc. including cost of bolts and nuts, screws, welding rod complete fixing in position
Providing and fixing aluminum work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate z sections and other sections conforming to Is: 733 and IS : 1285 of Jindal, Hindalco, Mahavir or equivalent make approved by Engineer in Charge , fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC Plug/neoprene felt etc. aluminum sections shall be smooth, rust free, straight, mitered and jointed mechanically wherever required including cleat angle, aluminum snap beading for glazing/paneling, C.P.brass/stainless steel screws, all complete as per architectural drawings and the directions of Engineer-In-Charge. (Glazing and paneling to be paid for separately) :
For shutters of doors, windows & ventilators including providing and fixing hinges/pivots and labour for fixing of fittings wherever required including the cost of PVC Plug / neoprene gasket required
Providing and fixing glazing in aluminum door, window, ventilator shutters and partitions etc. with PVC Plug/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminum snap beading shall be paid in basic item)
Providing Polyester Powder coating 50 micron any coloured specified to alumnum section of various sizes including carriage of material from market to workshop & workshop to site of work.
Providing & fixing ACP Sheets of various thickness High Class ISI marked complete in all respect as per the directions of Engineer-in-charge. 6mm thick ACP Sheet
Factory manufactured flush door fixed in position iron hinges, etc (excluding the cost of any fittings other than specified above but including labour for fixing the same in position (Code : II Revision IS-2191 Part-I) 1973 Commercial with elm or gurjan facing on both \ Sides with laminated core and lipped edges:- 35mm thick
Cost of aluminum fittings complete for doors, windows such as tower bolts, handles,Stoppers and screw etc. for these fittings (Excluding sliding bolt) For shutter area above 0.50 sqm
Providing and fixing aluminum sliding door bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete : 300mm x 16mm
Preparation of plastered or concrete surface for painting (including sand papering the surface) using ready mixed cement based wall putty by applying two or more coats to get required finish
Applying priming coat with cement primer in all shade on newly plastered or concrete exterior surface
Wall painting with plastic emulsion paint of approved brand and manufacturer to give an even shade (two or more coats)
Finishing walls with Premium Acrylic smooth exterior paint with silicon additives of required shade with two or more coats applied @ 1.43litre/10 Sqm over and including base coat of water proofing Cement Paint applied @ 2.20 Kg/10 Sqm
Preparation of plywood surface for painting including sand papering the surface and applying filling with approved quality fillers consisting of white lead, linseed oil, Varnish, and Chalk Mitti ncluding finishing the surface to required finish complete.
Applying pink primer or aluminum priming coat on wood work including preparation of surface knotting and stopping etc.
Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade.
Applying priming coat with metal primer on new steel or iron work including preparation of surface.
Construction of Plinth protection complete
Earth work in exavation in foundations, trenches, etc. in all kinds of soil where pick jumper work is not involved and not exeeding 2.0 Mtr. depth and subsequent filling around masonary in 15 cm layers with compaction including disposal of all surplus soil as directed within a lead of 30 Mtr. complete in all respect as per specifcation, drawing and to the entire satisfication of Engineer In-Charge.
Cement Concrete 1:8:16 with 40mm guage stone aggregate using mechanical mixer.
First class burnt brick work laid in cement sand mortar 1:5 in foundation and plinth.
Base course of floor consisting of 100mm thick cement concrete 1:8:16 with stone aggregate 40mm guage and 100mm fine sand filling using mechanical mixer for mixing of material
Marble stone flooring with 18-20 mm thick marble stone, as per sample of marble approved by Engineer-in-charge, over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry, including rubbing and polishing complete with : Udaipur Green Marble Tiles of various sizes 18mm to 20 mm thick. Slabs sizes above 0.50 sqm
12.5 mm thick cement plaster 1:5 complete in all respect as per specifcation, drawing and to the entire satisfication of Engineer-In-Charge.
Public Health
Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 of E.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing. Single Socket Type A
110mm o/d single socket SWR UPVC pipe lines laid complete
75mm o/d single socket SWR UPVC pipe lines laid complete
Providing and fixing in position SWR UPVC special for soil waste vent or anti syphonage pipes as per as per IS - 14735 including cutting and wastage etc. cutting holes in walls roofs or floors etc. and making good to its original condition but excluding cost of lead joining.
For 110mm o/d pipes
Elbow 90 Degree (All side socketed)
Vent Cowls
Coupler
Single Tee With Door
For 75mm o/d pipes
Elbow 90 degree (all side socket)
Vent Cowls
Coupler
Floor Trap 110mm x 75mm
Providing & Fixing in position M.S or heavy flat iron clamps made out of M.S flat iron not less than 5 mm of the approved design for fixing C.I. soil waste, vent or antisyhonage pipes to walls complete in all respects including cutting and making good the walls and floors etc. and painting.
M.S. Holder bats clamps for 100mm i/d HCI pipes
M.S. Holder bats clamps for 75mm i/d HCI pipes
Providing and fixing in position gully traps fixed in cement concrete 1:4:8 complete with Grating 150mm x 150mm, cover and frame clear opening 300mm x 300mm and out of side size 330mm x 330mm and chamber including cost of all bricks work in cement morter 1:5 cement concrete 1:2:4 in coping around cover and frame etc. as per standard design minimum depth of water should be 150 mm with a minimum seal 50mm.
100mm internal Diametre S.W.gully trap with H.C.I. grating and cast iron cover weighing approximately 7.26 kg. and frame clear opening 300mm x 300mm and out of side size 330mm x 330mm
Construction of brick masonry inspection chambers size as given below upto 0.60 metre average depth in 1:5 cement sand mortar, C.C.1:4:8 ( 150mm thick) in foundation, cement concrete 1:2:4 benching 12.50mm thick cement plaster 1:2 with a floating coat of 1mm thick of neat cement, R.C.C. 1:2:4 slabs 100mm thick cement concrete topping 50mm thick with 455mm x 455mm, 455mm x 610mm inside R.C.C. inspection chamber cover and frame (Weight as per I.S.I specifications) painted with 3 coats of black bitumastic paint conforming to I.S.I complete as per standard design.
600mm x 900mm inside with 455mm x 455mm cover and frame light duty double seal
Providing and laying, jointing, fixing and testing ISI Marked uPVC Pipe Lines as per ISI 4985-2000, including specials such as tees, bends, sockets, elbow etc., cutting, testing (including cost of specials) in the ground complete in all respects.
uPVC Pipe 6 Kgf/cm2 50mm i/d
Sub Head-1.2 Internal Water Supply System
CONCEALED IN WALL: Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-in- Charge), having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing including jointing of pipes & fittings, with one step CPVC solvent cement and testing of pipes complete as per direction of Engineer-in-Charge.
CPVC SDR 11 Pipe & fitting 16mm o/d
SDR 11 CPVC pipes & fittings 20mm o/d
CPVC SDR 11 Pipe & fitting 25mm o/d
CPVC SDR 11 Pipe & fitting 40mm o/d
Cutting chase in brick walls in cement or in floor for embedding G.I. or C.I pipes lines and making good the same to its original condition. Size 75mm x 75mm
qty same as GI P 15mm i/d to 25 mm
Cutting holes upto 23cm square through B.B. in cement walls or stone masonary wall in cement for pipes, and making good the same & finishing according to existing finish where required.
Through wall 11.43 cm thick
Through wall 22.86 cm thick
Providing, fixing and jointing G.I Union Couplings(of approved make with the approval EIC) as per IS 1879 in G.I. Pipe lines complete in all respect.
15mm i/d G.I. Union
20mm i/d G.I. Union
25mm i/d G.I. Union
40mm i/d G.I. Union
Providing, fixing and jointing Brass Ball valves screwed with SS/BRASS ball & spindle & Teflon seats, on G.I. Pipe lines including all carriages complete.
25mm i/d Brass Ball valves
40mm i/d Brass Ball valves
Sub Head - 1.3 Sanitary Installation
Providing and fixing in position Chinaware European type water closet P trap or S trap of approved make (to the approval of the Engineer-in-charge) consisting of 10 ltr. PVC flushing cistern ISI marked, PVC short bend 32 mm dia including cost of seat cover complete in all respect and to the entire satisfaction of Engineer in-charge.
Providing and fixing jet spray with 2'-6" long PVC pipe.With PTMT nut
Providing & Fixing in position C.P. Brass Hexa Nipple 15mm of approved make (to the approval of Engineer- in-charge ) complete in all respect.
Providing and fixing in position vitreous Chinaware white lIndian make large flat back or angular lipped front urinal 375 x 390 x 590 mm of approved make (to the approval of the Engineer-in-charge) consisting of C.P. brass Urinal waste Coupling dome type 32mm outer length 75 mm , C.P. brass Urinal Spreader Ocular-Regular and C.P. brass tube connection 300 mm long complete.
Providing and fixing partition for different type of urinals. Chittor Black Slabs 19-20mm thick marble partition size 375mm x 750mm
Providing and fixing in position vitreous chinaware white lavatory suites of approved make (to the approval of Engineer-in-charge) consisting of C.P. brass waste 32mm dia with one C.P. brass pillar tap including Rack Bolt Screw Pair 115mm long complete in all respect.
Size 550 mm x 400 mm x 815mm
Providing and fixing vitreous chinaware pedestal of approved make (to the approval of Engineer-in- Charge) for wash hand basin complete in all respect. Vitreous chinaware standard white pedestal for wash hand basin.
Providing & fixing in position PVC flexible tube connection of approved make (to the approval of Engineer-in-charge ) complete in all respect. PVC tube connection of size 15 mm x 375 mm with PTMT nut
Providing and fixing P.V.C Waste Pipe Collapsiable 32mm complete in all respect.
Providing and fixing in position C.P. brass soap dish of approved make (to the approval of Engineer-in- charge ) fixed into wall with rawl plugs and C.P brass screws complete in all respect.
Providing and fixing in position towel rails / ring of approved make (to the approval of Engineer-in-charge ) fixed in with rawl plugs embedded in walls with brass screws complete in all respect.
C.P brass towel ring
Providing & Fixing in postion 15 mm i/d bib cock of approved make (to the approval of Engineer-in-charge )complete in all respect.
C.P. brass Bib cock long nose/ long body without flange
C.P Brass bib cock foam flow without flange
Providing & Fixing in postion CP Brass Spout Operated Pillar Tap with base flange (for foot operated valve) of approved make (to the approval of Engineer-in- charge) complete in all respect (instead of Pillar tap in Lavatory Suites).
Providing & Fixing in postion stop cock / Angle valve of approved make (to the approval of Engineer-in- charge ) complete in all respect.
C.P.brass 15mm Angle valve without flange
C.P.brass 15mm Concealed stop cock with flange
Providing & Fixing in position C.P. Brass flange Dome of approved make (to the approval of Engineer-in- charge ) under various fixtures complete in all respect.
Providing & Fixing in position C.P. Brass extension piece 25mm long to 100mm long of approved make (to the approval of Engineer-incharge )with various fixtures complete in all respect. C.P. Brass extension piece, 25mm long to 50mm long
Providing & Fixing in position 5mm thick bevelled edge mirror of superior glass (of approved make) complete with 4mm thick hard board backing fixed in with rawl plugs 50mm, C.P. brass screws and washers and S/S Studs on top complete in all respect (as required by the Engineer-in- Charge) (Size 600mm x 450mm)
Providing and fixing in position premium range C.P. Brass Fittings and accessories of approved make (to the approval of Engineer-in-charge ) complete in all respect. C.P. Brass Accessories:
C.P. brass toilet roll holder with flap
Providing & Fixing in position C.P./Aluminium Khunti of approved make (to the approval of Engineer-in-charge ) fixed into wall with C.P. brass screws and rawl plugs etc. complete in all respect. C.P. Brass khunti with 3 pegs
Providing and fixing in position vitreous Chinaware white channel of approved make (to the approval of Engineer-in-charge) of size 600 mmx100mm including laying and fixing in cement concrete 1:2:4 complete in all respect.
Providing & placing in position on terrace (at all floor levels) HDPE water storage tanks of approved make (to the approval of Engineer -in-charge) with cover with suitable locking arrangement and making necessary holes for inlet, outlet and over flo pipes but without fittings and base support for tank. Double Layer Tanks
Providing and fixing in position automatic brass Ball Cock in tanks. Brass Ball Cock with rod and Plastic Ball
Brass Ball Cock with rod and Plastic Ball 32mm i/d
Brass Ball Cock with rod and Plastic Ball 25mm i/d
Providing and fixing in position G.I. Tank Nipple of approved make (to the approval of Engineer-in- charge) in PVC Water storage tanks complete in all respect.
G.I. tank nipple 25mm i/d
G.I. tank nipple 40mm i/d
Construction of Plateform complete as per specification & as desired by Enginer-in-charge
Sub Head-1.4 Flooring and Wall Tile
Providing and laying Anti skid Ceramic floor tiles of size 300x300 mm x 10 mm thick of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on flooring skirting and dado in 12.5mm thick cement plaster 1:3 in base and jointed with @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., completewhite cement slurry in joints including corners angles and beading.
Providing and fixing 1st quality ceramic glazed wall tiles Matt/Semi Matt/Glosy/Highly Gloss finish/Highlighter/emboss conforming to IS : 15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of size 250 x 330 mm & 300x300mm as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:4 (1 cement: 4 fine sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete.
Constructing brick masonry manhole in cement mortar 1:5 ( 1 cement : 5 coarse sand ) R.C.C. top slab 20cm thick using M-20 mix by using mixer and vibrator, TMT Fe500 @ 80.00 kg/per cum, foundation concrete 1:4:8 mix (1 cement: 4 coarse sand : 8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement: 3 coarse sand) finished with floating coat of neat cement and making 40mm thick benching in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement, Orange coloured PVC steps including RCC cover with frame complete as per standard design complete in all respects. Inside size 75x120 cm and 120 cm deep
Constructing brick masonry manhole in cement mortar 1:5 ( 1 cement : 5 coarse sand ) R.C.C. top slab 20cm thick using M-20 mix by using mixer and vibrator, TMT Fe500 @ 80.00 kg/per cum, foundation concrete 1:4:8 mix (1 cement: 4 coarse sand : 8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement: 3 coarse sand) finished with floating coat of neat cement and making 40mm thick benching in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement, Orange coloured PVC steps including RCC cover with frame complete as per standard design complete in all respects. Inside size 150x180 cm and 120 cm deep
Providing, laying in trenches to correct gradient and alignment and jointing of UPVC pipes having ISI specification IS:15328-2003 class-SN-8 marked make Supreme, Finolex, Kissan, Jain, Prince or equivalent good on them and laying the same in trenches to correct alignment and gradients, cutting and jointing, testing for water tightness and making good the leakages and defects including cost of specials (Specials and Solvent should be of same make as that of Pipes) complete in all respects. 200mm o/d pipe
RECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES: Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junction Boxes (Four way PVC 1½" deep for walls and CI 3" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):-
Wiring fan point (With fan box)
Wiring light point
Wiring call-bell point
Wiring 6 Amp. wall socket point
Wiring 6 Amp. Plug control comprising wall socket point
Wiring 16/20 amp. power plug control point
Wiring Computer supply terminal points recessed in wall etc., complete with powder coated/anodized concealed metal boxes required for suitable number of modules (Modular accessories) for having 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10/16/20Amp. Switches and blanking plate etc., and covered with Frame Plate and other petty material etc. including the cost of above material, cutting and filling up of chases (with finishing the surface):-
Wiring Computer terminal point having 3 Nos. 6Amp. 2/3 universal socket (shuttered), 1No. 16 Amp. switch with indicator and 1No. blanking plate (Modular accessories).
Wiring air conditioner supply terminal point recessed in wall etc., complete with powder coated/anodized concealed metal boxes required for suitable number of modules (Modular accessories) for having 25Amp. combined/ universal Socket (shuttered) and modular motor starter 25Amp. (2Module), covered with Frame Plate and other petty material etc. including the cost of above material, cutting and filling up of chases (with finishing the surface):-
Wiring AC supply terminal point having 1No. 25Amp. universal Socket (shuttered) erected at AC height and 1No. Motor starter 25Amp. erected at switchboard height.
RECESSED TV, TELEPHONE & NETWORKING SOCKETS OUTLET POINTS (USED FOR HGW, PVC CONDUIT & HDPE PIPE WIRING SYSTEM WITH MODULAR ACCESSORIES): Supply and erection of TV socket, Telephone socket and Networking socket points in powder coated/anodized concealed metal boxes recessed in wall required for suitable number of modules (Modular accessories) for having TV sockets, Telephone sockets RJ11 & Networking socket RJ45 (one module),covered with Frame Plate and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):-
Wiring Telephone socket point RJ11 (one module)
Wiring Networking socket point RJ45 (one module)
PVC INSULATED SINGLE CORE FR COPPER CONDUCTOR CABLE: Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:-
Overall size 1.5sq.mm (Un-sheathed)
Overall size 2.5sq.mm (Un-sheathed)
Overall size 4sq.mm (Un-sheathed)
Overall size 6sq.mm (Un-sheathed)
Overall size 10sq.mm (Un-sheathed)
COPPER CONDUCTOR CABLE FOR SPECIAL ELECTRICAL SERVICES:
Supply and erection of CAT 6 with 23AWG solid bare copper conductor, special grade PE insulated with star separator, 4 pair Unshielded Twisted Pair (UTP) industrial cable, FR PVC sheathed Class-E, 250 MHz of bandwidth, supporting data transfer speeds of up to 10 Gbps (10GBASE-T) for distances up to approximately 180 feet, cables are manufactured and tested to meet the ANSI/TIA 568-C.2 and ISO/IEC 11801 Class E Standard left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge.
CAT 6 LAN cable
XLPE INSULATED ARMOURED CABLES (ON SURFACE): Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed armoured and served cable 1100 volts grade as per IS:7098 (Part-1)1988 to be laid (On Surface) as per PWD General Specifications:-
Overall size 10sq.mm (2Core) Armoured (On-Surface)
HEAVY GUAGE WELDED CONDUIT PIPES: Supply & erection of Heavy guage welded conduit pipe (ISI marked) as per IS:9537:Part-II for wiring purposes including bends, junction boxes, Steel hooks, GI saddle clamps and other petty materials etc., where necessary including painting as per PWD General Specifications:-
Supply & erection of 19/20mm dia. M.S. conduit pipe (1.6mm thick), white painted suspension rod for ceiling fan.
PVC, HDPE PIPES & PVC FLEXIBLE PIPES: Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:-
Heavy gauge PVC conduit pipe 25mm dia. (ISI marked) Flushed
Heavy gauge PVC conduit pipe 32mm dia. (ISI marked) Flushed
Supply and erection of PVC flexible pipe complete without compression glands, locking arrangement, check-nuts as required:-
PVC flexible pipe 25mm dia.
PVC flexible pipe 32mm dia.
G.I. EARTHING :- Earthing with G.I. wire/ rope in G.I. pipe partly recessed and partly on surface complete with 150cm long 50mm dia. G.I. earth pipe (Cutting threads and 36 Nos. holes, 1cm dia. to make a mesh around the GI Pipe) with G.I. reducing socket including erection of the same, 4.50 metre (14.76 feet) below ground level with 20Kg. charcoal & salt mixture etc., up to 8 metre in length (including boring & refilling).
Earthing with 8 S.W.G. (4mm dia.) G.I. wire in 15mm dia G.I. pipe with G.I. reducing socket 50mm x 15mm (upto 8Metre in length)
SUPPLY AND ERECTION OF WIRING ACCESSORIES: Supply and erection of switches, sockets and other accessories (flush piano type/ modular accessories) in the existing bakelite/ modular cover frame including fixing & connections and petty material etc.:-
Modular RJ-45 Modem Jack for Computer (One Module)
MINIATURE CIRCUIT BREAKERS: Supply and erection of Miniature Circuit Breaker MCB's for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:-
MCB Single Pole 6-32amp. (10kA, Curve-C)
MCB Double Pole 40amp. (10kA, Curve-C)
MCB Four Pole 50, 63amp. (10kA, Curve-C)
MCB Triple Pole 50, 63amp. (10kA, Curve-C)
SHEET METAL DOUBLE DOOR DISTRIBUTION BOARD FOR MCB/ RCBO/ RCCB's: Supply and erection of sheet metal Double Door Distribution Boards IP 43- IK09 metal door (dust protected) as per IS 8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars, shrouded neutral bars, earth bars, cement spill protector, colorcoded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting miniature circuit breakers/ RCBO's/ RCCB's in the distribution board (For SP&N distribution board with provision DP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings and for TP&N horizontal distribution board with provision TPN/ FP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings) as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc:-
SP&N Double Door Distribution Board 12 way each
TP&N Horizontal Double Door Distribution Board 4 way each
COPPER EARTHING: 8 SWG COPPER EARTHING : Earthing with 8 SWG (4mm dia.) electrolytic copper wire thimbled (1No. copper thimble with suitable size steel bolt, washers & double nut) with 30cm x 60cm x 2mm thick copper plate (made cylindrical) burried below ground level in the hole of excavation having bore dia. 125mm and surrounded by salt & charcoal dust mixture (20 kg.) including fixing the copper wire run through 20mm dia. G.I. pipe (A-Class) recessed in wall and in floor etc., up to suitable Length in metre (including bore Length). G.I. pipe 20mm dia. (A-class) of suitable Length should be laid in the hole of excavation 1 feet below ground level and having GI Reducer 50mm x 20mm with PVC Cap (For pouring water) fixed on the top level of the pipe. 300mm x 300mm x 300mm deep haudi of First class bricks finished with 1:4 cement plaster and haudi covered with cast iron lid having size 300mm x 300mm (Heavy) around the hole of excavation:-
Earthing with 8 SWG (4mm dia.) copper wire thimbled with 30cm x 60cm x 2mm thick copper plate burried 4.50 metre (14.76 feet) below ground level (up to 8metre in Length) with G.I. pipe 20mm dia. (A-class), 3metre long
XLPE INSULATED UN-ARMOURED CABLES (LOOSE):
Overall size 35sq.mm (3½ Core) Un-armoured (Loose)
MCCB's (FOR PANELS & SHEET ENCLOSURE):
Supply and erection of Moulded Case Circuit Breaker (Panel mounting Cubical type) in the existing Cubical Panel (confirm to IEC:60947-2) having Ics=100% Icu, 100% neutral with spreader terminal links, Extended rotary handle and relevant PWD general specifications complete with G.I. Bolts, Nuts & Connection on both sides of MCCB with suitable size of thimbles etc:-
MCCB Four Pole 63/80/100amp., 415volts, ≥25kA Fixed Magnetic and Adjustable Thermal Setting
ON LOAD CHANGEOVER SWITCH (With Sheet Enclosure):
On Load Change Over Switch Four Pole 63amp., 415volts
Supply and erection of sheet metal double door vertical distribution boards IP 43-IK09 metal door (dust protected) as per IS:8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars for each phase, 2 Nos. shrouded neutral bars, 2Nos. earth bars, cement spill protector, color-coded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting MCCB's as incomer and outgoings SP/TP miniature circuit breakers in the distribution board as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc.:-
TP&N Double Door Vertical DB's 8 way each (With provision of FP MCCB 160amp.)
Supply and erection of Double Walled Corrugated (DWC) HDPE pipe to be laid 1mtr. below ground level including excavation placing the pipe in position and back filling with excavated soil etc. of the required size:-
Double Walled Corrugated HDPE Pipe 63/ 51mm (Outer/ Inner dia.)
Ceiling Fans & LED Light Fixtures:
Supply and Erection of 3 Star Rating Ceiling fan Suitable size 48” (1200mm) Full Aluminium Body, 3 Nos. of Blades, white in colour. The mounting type is down rod mount. The product should possess a minimum air delevery of 218 CMM. The rated speed of the product must be minimum of 350 revolutions per minute and 5 Nos. of speed. The approximate weight of the product should be 4kg and 180gms (without packing) or higher. The product should have a manufacturer's guarantee/ warranty of minimum 2 years. The product should be complete in all respects with fan motor, bladeset, down rod, conopy set, shackle kit, twisted wire etc., including erection & testing of ceiling fans having connection with PVC insulated PVC sheathed tow single core copper conductor (FR) cable 0.75 SQ MM. Complete in all respects as desired by the Engineer in charge of work at site.
Supply and Erection of Heavy Duty Exhaust Fan Suitable size 12” (300mm) including Louver shutter, connection & testing complete in all respects as desired by the Engineer in charge of work at site. Trade Name : Exhaust Fan, Blade Sweep : 300 mm (12”), Type of motor : Permanent capacitor induction motor, C75 Rated Voltage : 230 volts, 50 Hz, AC. single Phase, Test voltage : 230 volts, 50 Hz, .AC. I Phase, Frequency : 50 Hz., Capacitor rating : 1.0 F, 400V, 50 Hz, AC., Rated watts at full (load) speed & at 230V. : 27 watts., Current in amps at full speed & at 230 V. : 0.12 Amps., Power factor : 0.9 min., Rated full speed & at 230 V : 1310 rpm., Rated air delivery at 230 V : 800 M3/hr, Rated Service value : 30 m3/hr/watt, No. of blades leaves : Five, Type of blade leaf : Plastic (PP), No of running positions : One position, Class of Insulation : Class “E”, Type of bearings : Oil impregnated self aligned bush bearings.
Supply and Erection of 40 Watt LED batten with Pressure die cast aluminium housing & polycarbonate diffuser and efficacy of LED fixture minimum 100 lumens per watt complete in all respects as approved and desired by the Engineer in-charge at site. The certification and Specifications of the LED Fitting's should be as approved by O/o Advisor (Technical), Govt of Punjab vide Letter no.AT/2021/GL/1410-1422 Dated 06/05/2021. Besides this the Lighting Fixture manufacturer should have inhouse NABL accredited LAB.
Supply and Erection of 100 Watt LED Flood Light fitting (including LED driver) with pressure die cast aluminium housing with control gear (IP 66 protection),THD< 10%, CRI minimum 70, High power LED with mandatory secondary lenses, toughened glass fitting, 4 KV SPD within driver and 10KV external SPD, efficacy of LED fixture minimum 120 lumens per watt, complete in all respects as approved and desired by the Engineer in-charge at site. LED Fittings as per specifications approved by Hon'ble Technical Advisor to CM Punjab vide letter No. AT-2021/GL 1410-1422 Dated 06/05/2021. Besides this the Lighting Fixture manufacturer should have inhouse NABL accredited LAB.
Supply and Erection of Wall fan plastic body 400mm 16" including flexiible wire and petty material etc. for connection and testing complete in all respects as desired by the Engineer in charge of work at site.
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.28 MB
SBD.pdf
Tender Documents • 15.18 MB
BOQ_320257.xls
BOQ • 0.60 MB
Download all tender documents and submit your bid