Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
₹59.8 L
EMD Value
₹59,810
Closing Date
5 Feb 2024, 9:30 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Karnataka Power Transmission Corporation Limited
Pallavi
Dismantling, Transportation (to and fro), Repair, Testing, Erection and commissioning of sick Power Transformer of rating 31.5MVA, 66/11KV(3Limbs), BBL make, Sl. No.4934/12 Failed at 220/66/11Kv Yerrandanahalli R/s in TL&SS, Division, Yerrandanahalli on total turnkey basis. PERCENTAGE TENDER BASIS
KPTCL/2023-24/SS/WORK_INDENT286/CALL-2
KPTCL/2023-24/SS/WORK_INDENT286/CALL-2
Open
Sub-Station
Two Tender Document System(Two Cover)
KPTCL SEE Transmission And Mantainance Ramanagara Circle
6 documents required · 2 mandatory · 4 optional
Minimum financial turnover (civil engineering construction works) not less than two times the annual payments from this contract (Rs. xxxxx Lakhs)
Satisfactoriy completed (atleast 90%) as prime contractor at-least one such similar work of value not less than Rs. xxxxxxx (80% of estimated cost of tender)
Executed in any one year the following minimum quantities of work (Cement Concrete - xxxx cum, Earthwork - xxxx cum, etc) (80% of peak rate of construction)
Tenderer or his identified Sub Contractor should possess valid Electrical License for executing building electrificatio works and should have executed similar electrical works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one year
Tenderer or his identified Sub Contractor should possess valid license for executing water supply / sanitary engineering works and should have executed similar works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one year
Owning the following key and critical equipment for this work (xxxx, xxxx, xxxx)
Liquid assets and /or availability of credit facilities of no less than Rs. xxxxxx Lakhs (estimated cash flow for 3 months of peak construction period)
Total value of civl engineering works executed and payments received in the last five years (year-wise)
List of existing commitments and ongoing works
List of works for which tenders already submitted
Banker Details for reference
Construction equipment owned by the tenderer and equipment proposed to be deployed on this contract, if awarded
Reports on the financial standing of the tenderer, such as profit and loss statements and auditor’s reports for the last five years
Qualification and experience of the key technical and management personnel in permanent employment with the tenderer and those that are proposed to be deployed on this contract, if awarded
List of Financial Resources with Certificates
The performance of the Transformer repaired / supplied by the Bidder in the past shall be a vital factor in determining the responsiveness of the tenderer. (In case, the bidder is a vendor for supply of minimum 33kV class and 5MVA capacity Transformers to public Utilities with minimum 02(Two) years of experience in manufacturing/repairing, testing and commissioning of 33kV class 5MVA or higher voltage class Transformers and the manufacturing unit/facility of the bidder is located within Karnataka state, then the clause stated above is not applicable).
Description of Tools and Plant held for execution of the work along with valid calibration certificate for testing and measuring equipment.
The qualification and experience of key personnel proposed for carrying out the work.
Bid, Bidders shall have adequate financial stability and status to meet financial obligation pursuant to the scope of this assignment and shall meet the following minimum criteria. Minimum Average Annual Turnover (MAAT) of the Bidder for best 03 (three) years out of last preceding 05 (five) financial years (on the date of tendering) ending on March shall not be less than 100% of the amount put to tender
Proof of PAN and Tax Registration number shall be furnished and uploaded.
₹1,500
₹59,810
12 Jan 2024
12 Jan 2024
7 Feb 2024
23 Jan 2024
23 Jan 2024
Dismantling, Transportation (to and fro), Repair, Testing, Erection and commissioning of sick Power Transformer of rating 31.5MVA, 66/11KV(3Limbs), BBL make, Sl. No.4934/12 Failed at 220/66/11Kv Yerrandanahalli R/s in TL&SS, Division, Yerrandanahalli on total turnkey basis. PERCENTAGE TENDER BASIS
Moving the faulty transformer from plinth to about 10Mtr at site
Loading of faulty Transformer main tank with active parts without oil and loading of transformer accessories such as radiators, bushings (HV&LV), cooling fans,Marshalling Box, Buchholz Relay, PRV, MO...
Transportation of faulty power transformer main tank along with accessories such as radiators, bushings, cooling fans,Marshalling Box, buchholz relay, PRV, MOG, OSR, Breather and RTCC panel etc from 2...
Unloading of the faulty power transformer tank with active parts and accessories at firms work
Dismantling faulty 31.5MVA transformer for joint inspection at repairers premises including all activities such as opening of top cover, de-tanking of core and winding, separation of HV/LV coils, cond...
Cleaning, repairing and painting inside the 31.5MVA Power tranformer tank with hot oil bath and acid proof epoxy paint and painting outside the tank with enamel paint after thorough cleaning including...
Repair and overhauling of 31.5MVA OLTC divertor switch including change of oil,lubrication and repalcement of gaskets and other parts which are locally available
Reconditioning of 31.5MVA Power Transformer RTCC panel and replacement of all types switches,indicating lamps,annunciator windows, OTI, WTI, Tap position indicator etc If required, as per joint inspe...
Re-assembly of 31.5MVA Transformer Core and winding with new solid insulation
Drying of active parts of 31.5MVA transformer at Factory in Oven
Tanking the 31.5MVA Power Transformer assembly, giving connection, providing new gaskets and insulating materials conforming to relevant IS, putting back the cover, tightening the fixtures, fixing the...
Testing the 31.5MVA transformer for routine tests at firms(repairer premises as per IS 2026-1983 with latest amendments including temperature rise test which is to be carried out if required as per KP...
Loading of repaired good transformer tank with active parts and accessories at firms work with oil (As per latest specification of KPTCL)
Transportation of repaired good transformer with accessories such as radiators, bushings, cooling fans, OLTC drive mechanism, RTCC panel, Marshalling Box buchholz relay, PRV, MOG etc from repairers ...
Unloading of the repaired power transformer tank with active parts and all accessories at the destination station of KPTCL
Moving the repaired transformer to the plinth for 10mtr at site(Total mass)
Assembly of tranformer parts like bushings, radiators, Conservator, breather etc
Filling of oil to the main tank and OLTC tank filtering the oil including filtering till attainment of prescribed BDV value including labour, filtering equipment along with accessories. The minimum BD...
Reconditioning of 31.5MVA Power Transformer accessories like radiators,conservator by hot air circulation along with pressure test of radiators and reconditioning of transformer mounted mechanical rel...
Providing 2 nos of SCADA compatible analog O/P of 4-20 mA and remote temperature indicator for WTI and OTI to be provided along with necessary RTC's, if necessary for 31.5MVA Power Transformer
Wiring of 31.5MVA Power transformer mounted protection devices to marshalling box,marshalling box to C&R panel and RTCC panel,OLTC DM box to RTCC panel, and assisting in testing by RT engineers and c...
Impulse test on transformers below 72.5 kV
Temperature rise test for 31.5 MVA transformer
Providing new copper windings in place of damaged winding including cost of material and labour, drying etc., taking into account value of released copper which has to be retained by the repairer (M...
Providing HV static rings for tap coils including new insulation
Providing solid insulation materials for replacement to damaged or burnt limb.
Complete new EHV grade mineral oil required for commissioning the transformer should be supplied from KPTCL approved vendors as per KPTCL specification confirming to IEC 60296.Tested oil result has to...
Providing new CRGO lamintion to the core in place of damaged lamination wherever necessary including cost of materials and labour .(meeting IS 3024 or M4 or better standard)
Providing new 72.5kV/800A Class condenser bushings, DDF test reports of all the bushings should be provided at the time of acceptance tests.(meeting IS 2099 standards). If required, as per joint inspe...
LV bushing with metal parts.(meeting IS 2099 standards). If required, as per joint inspection at repairer premises.
Silicagel breather 5 kg capacity (02 nos) with silica gel
Silicagel breather 2 kg capacity (02 nos) with silica gel
Repair of cooling Fans ( if necessary)
Released Scrap Copper which has to be retained by the repairer under buy back
Released CRGO lamination to be retained by the repairer under buy back
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
tender document-Yerrandanahalli.doc
Tender Document • 1.07 MB
YHL BBL make- price bid, only for reference purpose,not to be uploaded.docx
Tender Document • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .