| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.6 LAccepted-AOC 101 1ST FLOOR JASOL RESIDENCY 14TH CROSS KANAKANAGAR R T NAGAR POST BANGALORE 560032 | BANGALORE | BANGALORE | KARNATAKA | 560032 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹32.4 L+₹1.2 L (3.78%)Rejected-Finance | L2 | Rejected-Finance Rejected | |
| 3 | L3₹34.6 L+₹3.4 L (10.8%)Rejected-Finance MILITARY ENGINEER SERVICES GARRISON ENGINEER EAST JABALPUR 482 011 | L3 | Rejected-Finance Rejected | |
| 4 | L4₹34.9 L+₹3.7 L (11.7%)Rejected-Finance | L4 | Rejected-Finance Rejected |
Tender Value
₹29 L
EMD Value
₹58,000
Closing Date
25 Oct 2021, 6:00 pmClosed
GE(North) Bangalore
T/64, Meanee Lines, MEG and Centre, Bangalore-42
SPECIAL REPAIRS BUILDING NO T-58 ORs LINES OF 255 ARMY AVN SQN AT BANASWADI UNDER GE (NORTH) BANGALORE.
2021_MES_478013_2
8258
Open Tender
Civil Works - Others
Item Rate
90 days
Banaswadi
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE(North) Bangalore
₹58,000
Yes
12 Nov 2021
29 Sept 2021
1 Nov 2021
29 Sept 2021
25 Oct 2021
13 Oct 2021
Amount
B/R WORKS
Dismantling of Asbestos cement (corrugated, semi corrugated sheets as in roof coverings including ridges etc complete all as specified and as directed.
Dismantling timber scantlings 40 sq. cm and over in section, in any position as in Framed work etc complete all as specified and as directed
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed.
Dismantling wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards / slabs / blankets, any thickness, including cover fillets etc complete all as specified and as directed
Demolition of brick work /stone masonry/PCC block masonry built in cement mortar of any description all as specified and directed.
Demolition of cement concrete and pavings not exc. 15 cm thick (below or above ground level) complete all as specified and as directed.
Demolition of reinforced cement concrete including reinforcement cut as required to facilitate demolition of any description and in any position not specifically provided for complete all as specified and as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding but not backing, removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed.
Dismantling of stone sett paving of any description or thickness in floors, aprons etc., laid bedded and pointed in any cement mortar including removing off the premises complete all as specified and as directed.
Taking down cement plaster of any description hacking for key or raking out joint on old brick work / stone / concrete surface complete all as specified and as directed.
Hacking out old broken glass (any thickness, size, quality or description) from wooden surface, concrete or brick surrounds glazed with putty or fixed with beads all as specified and as directed.
Taking down chowkats or frames with shutters without taking off shutter from frames area not exc. 1.5 sqm each, including cutting holes for removing the hold fast and making good distrubed surface of wall complete all as specified and as directed.
Taking down chowkats or frames with shutters without taking off shutter from frames area exc. 1.5 sqm but n.exc. 4 sqm each, including cutting holes for removing the hold fast and making good distrubed surface of wall complete all as specified and as directed.
Taking up or down steel tubing and connections including cleaning for refixing serviceable pipe or removal balance pipe of 15 mm dia bore complete all as specified and as directed.
Taking up or down steel tubing and connections including cleaning for refixing serviceable pipe or removal balance pipe of 20 mm dia bore complete all as specified and as directed.
Taking up or down steel tubing and connections including cleaning for refixing serviceable pipe or removal balance pipe of 25 mm dia bore complete all as specified and as directed.
Dismantling of cast iron or reinforced concrete drain pipe up to 100 mm dia including fittings, jointed in cement mortar and taking out trenches if reqired etc complete all as specified and as directed.
Dismantling water tanks exc 150 ltr but not exc. 500 ltr and removing to store complete all as specified and as directed
Dismantling water tanks exc 1000 ltr but not exc. 2000 ltr and removing to store complete all as specified and as directed
Rolled mild steel sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates confirming to IS Fe-410-W (Gde- E-250) quality- B complete all as specified and as directed.
Rolled Mild steel framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; frame work of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and as directed.
Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.5mm thick of any colour having tensile strength of 550 Mpa as in roof covering /cladding to wall fixed with self tapping screws as specifed and as directed.
Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tenisile strenth of 550 Mpa as in roof covering cladding to wall, pre fixed with self taping screwes as specified and as directed.
Decorated PVC false ceiling of size 600mm x 600mm x 5 mm thick, used as a panel insert in a frame work made out of using anodized aluminum T-section of size 25mm x 25mm in square pattern of grid size 600mm x 600mm, the aluminum frame work shall be supported from the ceiling with the help of J hook and 4 mm GI wire of required size to maintain the proper levels etc., the aluminum frame work is supported on side wall with the use of aluminum L section of size 25mm x 25mm angle complete all as specified and as directed.
Plain Cement Concrete (1:4:8), type D-2 using 40mm graded stone aggregate as in sub base to floors, 75mm thick complete all as specified and as directed.
Plain Cement Concrete (1:2:4), type B-0 using 12.5 mm graded stone aggregate as in floors 25mm thick, as in levelling course in floors complete all as specified and as directed.
Non skid ceramic coloured tiles 7-8mm thick(square / rectangular) area of each tile exceeding 0.06 sqm but n.exc 0.11 sqm as in floors set and jointed in neat cement slurry and pointed in coloured cement to match over and including 15mm thick screed bed in CM (1:6) complete all as specified and as directed.
Matt finished non skid ceramic coloured tiles 7 to 8 mm thick square / rectangular area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in coloured cement to match over and including 15mm thick screed bed in CM (1:6) complete all as specified and as directed.
All as per Sl Item No. 1.028 above but as in skirtings over and including 10mm thick backing coat in CM(1:3).
Glazed coloured ceramic tiles as in vertical surfaces 300x450x7 mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface over and including backing coat 10mm thick in CM (1:3) on fair faces of brick work or concrete surfaces complete all as specified and as directed.
75 mm thick plain cement concrete (1:3:6) type C2 using 40 mm graded stone aggregate as in plinth protection etc, finished even and smooth without using extra cement complete including joints filling with sealing compound Grade "A" complete all as specified and as directed.
Chequered cement concrete designer tiles of size 300 x 300 x 25mm thick, exterior grade, coloured glossy finish, rubber pressed, set, jointed and pointed in neat cement slurry with grey cement and pigment to match the shade / colour / matrix of tiles as in floor over and including 15mm thick screed bed in CM (1:6) complete all as specified and as directed.
Machine pressed precast cement concrete inter locking paver blocks any shape and size conforming to IS 15658-2006 of 60mm thickness, of M-35 grade with grey cement and pigment fixed over 50mm thick sand cushioning complete all as specified and directed.
Precast cement concrete block masonry with solid blocks exc. 10 cm in width and setting in cement mortar 1:6 type C1 1:3:6 ( using 20 mm graded aggregate) complete all as specified and as directed.
15mm thick rendering on brick or concrete surface in cement mortar (1:6) and finishing the surface with even and smooth without using extra cement complete all as specified and directed.
Rendering 15mm thick in CM(1:4) mixed with water proofing compound as per manufacturers instructions finishing the surfaces even and smooth without using extra cement including necessary scaffolding complete all as specified and directed. NOTE:- WPC will be measured and paid separately under reelvent items.
Supply only integral liquid water proofing compound all as specified and as directed.
1.25 mm thick pressed steel frame of size 125 x 60 mm suitable for door with one ore more rebate including necessary fixing lugs, hinges, locks strike plate etc complete all as specified and as directed.
Plain Cement Concrete (1:2:4), type B1, using 20mm graded stone aggregate as in copings, bed blocks, hold fasts etc., complete all as specified and directed.
35mm thick flush shutter solid core construction with decorative choice lamination both sides of shutter, kiln seasoned and chemically pressure treated complete all as specified and as directed.
Solid PVC door frame (single rebated) of size 60mm x 30mm made out of solid PVC foam with homogenous fine cellular structure having smooth outer integral skin with suitable metal stiffner and fixed with 100 x 8 sheet metal CSK screws complete all as specified and as shown on drawings. NOTE:- Door frame shall be water proof, termite proof, elegant and should have excellent screws holding strength to fix hinges and hold doors properly for a long life.
Factory made solid PVC moulded door shutters 28 to 30 mm thick (stile), with 2, 4 or 6 raised panel design with 2mm thick moulded prelam PVC Sheet on the front face & 2mm thick plain colour PVC sheet on back face etc., complete all as specified and as directed.
Aluminum powder coated of any shade / colour as approved as in ventilators with adjustable including 4mm thick figured glass louvers, fixed in qtr portion, without sash bars, aluminum section weighing 0.55 kg/m including necessary jointing cleats, glazing clips, rubber packing, anodised aluminum snap beading, screws, including stainless steel wire cloth 0.36 nominal dia of wire and average width of aperture 1.18mm all as specified and as directed.
Aluminium anodised tower bolt 200mm long of extruded section etc complete all as specified and as directed.
Aluminium anodised tower bolt 150mm long of extruded section etc complete all as specified and as directed.
Aluminium alloy, anodised sliding door bolt 300 mm long with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded section and fixing bolts and sliding bolts of extruded section or cast aluminium alloy etc complete all as specified and as directed.
Butt hinges, heavy weight, stainless steel of size 100 mm long, 35 mm over all width, and 3 mm thick and fixed complete as sepecified and as directed.
150 mm long aluminium handle, cast type, anodised etc complete all as specified and as directed.
150 mm long floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floors etc complete all as specified and as directed.
300mm long, brasss ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and as directed.
Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples etc complete fixed in repairs all as specified and as directed.
Sheet glass 4mm thick ordinary quality and glazing with oil putty in square not exceeding 0.5 sqm in each pane all as specified and as directed.
Plain Cement Concrete, (1:2:4), type B1, using 20 mm graded stone aggregate as in copings, chajja kerbs, roof padding / staging of water tank etc including necessary fromwork, weathering, slightly rounded or chamfered angles and throating complete all as specified and as directed.
Steel formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, also splays between floors and beams, for flat rough finished surfaces of concrete complete all as specified and as directed.
Reinforced Cement Concrete (nominal mix), type B-1, (1:2:4) using 20mm graded stone aggregate as in beams, cantilevers, bressummers, lintels over 1.5m span etc complete all as specified and as directed.
Precast Reinforced Cement Concrete (1:2:4), type B1, using 20mm graded stone aggregate as in cover slabs of man hole, landings, chullah hoods, chajja, water troughs, mangers, shelves and similar articles with plain faces set in CM (1:6) complete all as specified and as directed.
TMT steel bars 10mm dia and over, cut to length bent to shape required including cranking bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
TMT steel bars 6mm to 8mm dia as in stirrups cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips all as specified and as directed.
16mm dia CPVC pipes SDR 11 and plain CPVC SDR 11 fittings, fixed to wall, ceiling or laid in floors including all fittings and specials complete all as specified and as directed.
20mm dia CPVC pipes SDR 11 and plain CPVC SDR 11 fittings, fixed to wall, ceiling or laid in floors including all fittings and specials complete all as specified and as directed.
25mm dia CPVC pipes SDR 11 and plain CPVC SDR 11 fittings, fixed to wall, ceiling or laid in floors including all fittings and specials complete all as specified and as directed.
Rotational moulded polythene water storage tank (cylindrical vertical with closed top) with ISI mark embosed on it, hoisted and fixed in position complete all as specified in SSR part I capacity of tank 2000 ltrs complete all as specified and as directed.
Rotational moulded polythene water storage tank (cylindrical vertical with closed top) with ISI mark embosed on it, hoisted and fixed in position complete all as specified in SSR part I capacity of tank 500 ltrs complete all as specified and as directed.
25mm dia ball float valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed all as specified and as directed.
25 mm dia gun metal, globe or gate valve with iron wheel head screwed both ends for iron pipe and including taking down old gate valve all as specified and as directed.
Vitreous china wash basin white, flat back, size 550 x 400mm excluding taps, waste, chain & plug and porcelain stopper but including brackets, 32 mm bore waste stainless steel coupling and LDPE pipe 600 mm long fixed in repairs complete all as specified and directed.
Vitreous china wash down water closet pan (pedestal pan) including fixing bolts, flush pipe anti syphonage pipe, plastic water closet seat black, closed pattern with flat bottom and cover, mild steel chromium plated or aluminium hinging device etc complete of cera model cat pt no. 2008 fixed in repairs complete all as specified and as directed.
Vitreous China squatting pan, ‘Orissa’ pattern, size 580 x 440 mm white, with integral foot rests including PVC(SWR) 'P' or 'S' trap connecting to flush pipe and to anti syphonage pipe, etc. complete including making good to floor fixed in repairs complete all as specified and directed.
Vitreous China urinals, bowl type (back or corner wall type), complete fixed in repairs including providing and fixing plugs, bedding the urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; supply and fixing automatic flushing cistern with brackets, flush pipe, grating and union for discharge pipe complete all as specified and as directed.
PVC valveless, syphonic action type, flushing cistern, Duo flush cistern 10ltr capacity,low level, white, with inlet, ball valve, float and handle including brackets, connections to pipes and fixing of chain and pull, or lever, fixed in repairs complete all as specified and directed. MAKE:- Cat No-502 of Prayag or equivalent in any approved make as in CA.
15mm dia Pillar tap PTMT fancy type any colour screwed, for iron pipe and fixed in repairs complete all as specified and as directed.
15 mm dia bib tap fancy type long body, standard of PTMT any colour high pressure screwed for iron pipe and fixed minimum weight 120gms fixed in repairs complete all as specified and as directed.
125 mm dia bore swivel shower of PTMT any colour for fixing with 15mm dia pipe, minimum weight 40gms fixed in repairs complete all as specified and as directed.
15mm dia stop cock / angle cock PTMT fancy type any colour screwed, for iron pipe fixed in repairs complete all as specified and as directed.
PVC connections 15 mm size with PTMT nuts of length 450 mm long, all as specified and as directed.
PVC urinal waste pipe 32mm dia, 800mm long, complete all as specified and as directed.
75mm bore PVC (SWR) floor trap plain with grating including jointing with solvent cement complete all as specified and as directed.
Grating doom 100mm dia of PTMT (Minimum weight 25gms) complete all as specified and as directed.
110 mm bore PVC (SWR) pipes, type 'B' single socketed in any length with rubber ring joints laid in trenches or in floors complete all as specified and directed.
75 mm bore PVC (SWR) pipes, type 'B' single socketed in any length with rubber ring joints laid in trenches or in floors complete all as specified and directed.
110 mm bore PVC (SWR) pipes, type 'B' single socketed in any length with rubber ring joints fixed to wall including PVC clamps and necessary fittings complete all as specified and as directed.
75 mm bore PVC (SWR) pipes, type 'B' single socketed in any length with rubber ring joints fixed to wall including PVC clamps and necessary fittings complete all as specified and as directed.
110mm bore PVC (SWR) bends, any radius, type 'B' with access door complete all as specified and as directed.
75mm bore PVC (SWR) bends, any radius, type 'B' with access door complete all as specified and as directed.
PVC (SWR) vent cowl 110 mm dia, type 'B' all as specified and as directed.
Stainless steel decorative curtain rod of 25 mm bore with wood finishes (weight not less 400 gms per running meter) including fancy finial caps (02 nos in each curtain rod) etc complete all as specified and as directed.
Brass Chromium plated bracket for curtain rod of dia 25 mm dia made out of stainless steel flat not less than 20 mm wide 1.50 mm thick and overall length not less than 160 mm fixed with screws min 2 Nos with rawl plug of size not less than 50 mm long etc complete all as specified and as directed.
Complete removal of existing treatment by means of wire brushing, sand paper, manually or mechanically up to visible of plastered surface including rubbing and washing etc complete all as specified and as directed.
2mm thick wall care putty on wall including preparation of surfaces with sand paper to obtain smooth surface complete all as specified and as directed.
Preparing newly plastered suface of walls and applying two coats distemper oil emulsion, white or tinted over a coat of alkali resistance primer complete all as specified and as directed.
All as per Sl Item No. 1.091 above, but on old plastered surface of wall.
Preparing newely plastered surface of wall and applying two coats of cement based paint over a coat of alkali resistance primer etc complete all as specified and as directed.
Preparing old plastered surface of wall and applying two coats of cement based paint over a coat of alkali resistance primer etc complete all as specified and as directed.
Preparation of new steel and iron surfaces of any description, over 10 cm in width or girth , not otherwise described and painting with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed.
Preparation of old painted surfaces of steel surface of any description not otherwise described over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed.
E/M WORKS
Taking down carefully aluminium / copper wiring / power point wiring (light, fan,call bell socket or power circuits) complete and making good the disturbed surface of walls, ceiling etc including painting with same colour of the back ground complete all as specified and as directed by Engineer-in-Charge.
Point wiring complete with 1.5 sq.mm single core PVC insulated unsheathed cable 1100 volts grade multi stranded with FRLS copper conductor conforming to IS 694 drawn through and incl non-metalic rigid PVC conduit medium grade ISI marked including accessories concealed type run in walls including MS terminal boxes fabricated with 1.6 mm thick MS sheet concealed on walls with laminated sheet top cover 3 mm thick fixed with cadmium plated iron screws for housing the switches, switch socket outlets, fan regulators etc., including provision of 1.5 sq.mm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed for one light point controlled by one switch.
All as per Sl Item No. 2.002 above but for one fan point controlled by one switch/regulator.
All as per Sl Item No. 2.002 above but for one 3 pin socket out let 5 Amps on independent board.
All as per Sl Item No. 2.002 above but for one 3 pin socket out let 5 Amps on same board.
Point wiring complete with 2.5 sq.mm single core PVC insulated unsheathed cable 1100 volts grade multi stranded with FRLS copper conductor conforming to IS 694 drawn through and incl non-metalic PVC conduit medium density ISI marked incl accessories concealed type run on walls/ ceiling incl MS terminal boxes fabricated with 1.6 mm thick MS sheet concealed on walls with plastic laminated sheet top cover 3 mm thick fixed with cadmium plated iron screws for housing the switches, switch socket outlets, fan regulators etc., incl provision of 2.5 sq.mm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed. Contd/--2.007
Contd/--2.006 NOTE FOR Sl ITEM NO. 2.002 to 2.006 :- (i) The earth wire for the points in the same circuit can be looped from point to point. (ii) Earth wire shall be taken inside the conduit. (iii) Cost of terminal box is deemed to be included in the item rate quoted for point wiring. (iv) Cost of a circuit of any length of cable from DB to any switch/ socket board to be included in point wiring.
LED batten fittings, 18 watts, 6000K, (4 feet long), suitable for indoor applications wall mounted with extruded aluminium heat shink provision, efficient heat dissipation and integrated electronic driver, industrial batten type, powder coated top cover, with bipin holders, connector block , lamp etc., complete all accessories internally pre wired all as per Bajaj, Cat No.BCLAB 18 WH LED P or techno commercially equivalent makes specified in PS including connecting up twin core twisted flexible copper conductor cable all as specified and directed.
LED batten suitable for indoor applications 10 Watts, 2 feet with polycarbonate housing & integrated LED channel with white arcylic cover complete with all accessories all as per Bajaj Cat No. BCLSB 10 WH or techno commercially equivalent makes specified in PS including taking out old fittings all as specified and directed.
LED bulk head fitting of 10 Watts, energy efficient IP 65, luminaires / lamp complete all as per Bajaj Cat No. BIBWP 10 W LED or techno commercially equivalent makes including taking out old fittings all as specified and directed.
Switch Piano, flush type, 5 Amps, 240 Volts single pole with ISI marked complete all as specified and as directed.
Switch socket combination 3 & 2 pin, 5 Amps, 240 Volts, flush type multipurpose controlled by one switch all as specified and as directed.
Switch socket combination 2 in 1, 3 pin and 2 pin, 5 and 15 Amps flush type, universal complete all as specified and as directed
Socket outlet 2 in 1, 3 pin 5 A all as specified and as directed.
MCB single pole 240 Volts, 5 to 40 Amps complete all as specified and as directed.
MCB single pole and neutral 240 Volts, 5 to 40 Amps complete all as specified and as directed.
MCB DB, SPN 4 ways, 240 Volts with 200 Amps rated busbar, double door for housing MCBs all as specified and as directed.
Ceiling rose, surface bakelite type, 65 x 50 mm, 2 to 3 terminals all as specified and as directed.
MCB TPN 415 volts 63 Amps including taking down the existing complete as specified and as directed.
MCB DB, SPN 8 ways, 240 Volts with 200 Amps rated busbar, double door for housing MCBs all as specified and as directed.
MCB DB TPN 4 ways, double door with acrlic window, 240 volts with 200 Amps rated busbar for housing MCBs ncluding taking down the existing un serviceable MCB DB complete all as specified and as directed.
Stepped type electronic fan regulator flush switch type all as specified and as directed.
Sub main wiring complete with two runs of 6 sq.mm single core PVC insulated FRLS multistranded copper conductor cable 1100 volts grade, with one run of 6 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, concealed type drawn through non metallic rigid PVC conduit and conduit accessories including taking down the existing all as specified and as directed. NOTE :- Two runs of cable, one run of earth wire and one run of cinduit shall be measured as one unit for payment purpose.
Sub main wiring complete with two runs of 4 sq.mm single core PVC insulated FRLS multistranded copper conductor cable 1100 volts grade, with one run of 4 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, concealed type drawn through non metallic rigid PVC conduit and conduit accessories including taking down the existing all as specified and as directed. NOTE :- Two runs of cable, one run of earth wire and one run of cinduit shall be measured as one unit for payment purpose.
Earthing complete with galvanised steel plate electrode 600mm x 600mm x 6mm thick buried directly in ground (earth pit not less than 2.25mtr deep below ground level) with top edge not less than 1.5 m below ground level connected to earth lead by GI wire 4 mm dia by means of bolts nuts, check nuts, washers made out of galvanised iron connected to main switch all as shown in elect plate No 3 of MES SSR Part-I includingn excavation and earth work in any type of soil,funnel, 20 mm dia light grade GI watering pipe with chamber of PCC 1:3:6 type C1 40mm thick of size 450mm x450mm (1:2:4) type B1 for cover slab reinforced with 8mm dia TMT bars 10cm c/c both ways and with 6mm MS hook etc complete all as specified including testing on completion all as specified and directed.
30 Watt LED bldg security light fitting with pressure die cast housing along with prismatic polycarbonate difuser with IP 66 protection including taking out old fittings. Make:- Bajaj, Cat No.:- ENXT P 30L WH SY PC SD or Equivalent Makes & model
Brackets made out of GI tubing medium grade 25 mm bore , approx length 1.5 m long including MS clamps made out of MS flat iron 25 x 6 mm , nuts, bolts, washers etc before fixing applying two coats of aluminum paint over a coat of red oxide primer and removing the old existing GI bracket from building complete all as specified and as directed.
J PUSHPALATHA ENGINEER AND CONTRACTOR
deepak kumar vishwakarma
Matha Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .