Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance 201 3RD FLOOR A BLOCK SRI GURU TOWERS 80 FEET ROAD ANNA NAGAR MADURAI 625017 | MADURAI | TAMIL NADU | 625017 | Admitted-Finance |
| 2 | Rejected-Technical NO 167 1 MUTHUGOUNDENPALAYAM RING ROAD KUMARAPALAYAM ERODE 638 104 | ERODE | TAMIL NADU | 638104 | Rejected-Technical Not fulfiled the required criteria |
| 3 | Rejected-Technical | Rejected-Technical Not fulfiled the required criteria |
| 4 | Rejected-Technical | Rejected-Technical Not fulfiled the required criteria |
| 5 | Rejected-Technical P AND C TOWERS 2ND FLOOR 140 PERUNDURAI ROAD ERODE 638 011 | ERODE | TAMIL NADU | 638011 | Rejected-Technical Not fulfiled the required criteria |
Tender Value
Refer Docs
EMD Value
₹54.5 L
Closing Date
23 Aug 2022, 4:00 pmClosed
S.R. SENTHIL KUMAR
Office of the Commissioner of Police, Vepery, Chennai - 07
Selection of Contractor for Construction of New Integrated Command and Control Centre ICCC Green Building
2022_POLIS_241686_1
C.No.NP/13789/2021
Open Tender
Land/Building
550 days
Office of the Commissioner of Police, Vepery
Please refer Tender documents.
17 documents required · 17 mandatory
₹0
₹54.5 L
Office of the Commissioner of Police
21 Sept 2022
14 Jul 2022
23 Aug 2022
14 Jul 2022
23 Aug 2022
11 Aug 2022
21 Jul 2022
Amount
CIVIL AND EXTERNAL DEVELOPMENT WORKS
PLUMBING
SEWAGE TREATMENT PLANT
FIRE FIGHTING
MAIN ELECTRICAL
INTERNAL ELECTRICAL
EXTRA LOW VOLTAGE SYSTEM (ELV)
FIRE ALARM AND DETECTION (FDA) SYSTEM
SUBTOTAL OF THE ABOVE NINE ITEMS
GST 18% OF THE SUBTOTAL
Description of Work / Item(s)
Amount
SUB HEAD -1 : FIRE ALARM AND DETECTION (FDA) SYSTEM
Supply, Installation, testing and Commissioning of UL864 10th Edition UL Listed and FM approved Analog Addressable 2 Loop Fire Alarm control panel (expandable up to 50 Loops using same CPU). Panel shall be running on full digital protocol with 32 bit Microprocessor . The Panel shall be complete with 6" colour touch screen LCD Display. Fire alarm panel should have minimum capacity of 2500 detectors and devices in any combination and capable of making up to 50 loops in single panel using additional Loop cards. Each addressable loop shall be capable of taking 250 addresses per loop configuring either as all detectors or modules or any mix of both. The panel shall have the Fire Fighter Touch Screen Graphical Display panel to inform & guide Fire Fighters for carrying out Fire Fighting operations. The display shall have Hazmat icons indicating the presence of any explosive gas, liquids, poison, fumes etc. If this feature is not available in fire alarm panel then additional fire fighter touch panel along with necessary hardware and software should be provided by the manufacturers for fire fighters to guide them during emergency without any extra cost. To expedite system troubleshooting, the system cards shall have ground fault detection and diagnostic LEDs by card. In the display, simple building floor plan can be loaded in bitmap or jpeg format, On the map, the user will see an icon indicating the location of the event in the building in addition to a 'You-Are-Here' symbol to tell the responding person exactly where they are in the building in relation to the event. The system shall be polarity insensitive. The panel shall support degrade mode operation and shall have battery backup of 24 hrs. in normal condition and 30 minutes in Alarm condition. (Make : Honeywell - Notifier / Siemens - Cerberus (Fire Finder) / JCI)
Supply of Intelligent Loop Card designed for use with compatible analogue addressable panels, provides control and connection / communication to maximum 250 addressable device per loop in any combination.
Supply, Installation, Testing & Commissioning of UL268 6th and 7th edition compliance and FM approved Intelligent Addressable multi-criteria detector (optical and thermal sensors) complete with standard base, facility to mount in different comprehensive environment, Tri-colour detector-status LED with 360 ° view, microprocessor circuitry with error check; detector self-diagnostics and supervision programs, Rate-of-Rise Detection: 15°F / min. (8.3°C / min.) - Fixed: 135°F (57°C) , Field programmable as rate-of-rise or fixed temperature, Polarity insensitive, Superior EMI and RFI immunity, RoHS compliant. Detector shall have in-built isolator for better reliability, circuit integrity and advanced fault finding. Manufacturers not having in-built Isolator feature in detector shall consider Isolator base in place of standard base OR separate Isolator before and after every detector to comply the same without any extra cost, feature etc. including connections as per specifications complete as required. (Make : Honeywell - Notifier / Siemens - Cerberus (Fire Finder) / JCI)
Supply, Installation, Testing & Commissioning of UL listed and FM approved Intelligent addressable Class X type (Style 7), Control Module with built in dual isolator, polarity insensitive, Tri colour LED for status (Green for Normal, Yellow for Faulty and RED for activation), Operating Temp and RH: 0-49degC and <=95%. Module shall have in-built isolator for better reliability, circuit integrity and advanced fault finding. Manufacturers not having in-built Isolator feature shall provide separate Isolator before and after every Module to comply the same without any extra cost. (For AHU & Staircase Pressurization Fans, Hooters / Sounders / Strobes etc.)with back junction box. (Make : Honeywell - Notifier / Siemens - Cerberus (Fire Finder) / JCI)
Supply, Installation, Testing & Commissioning of Addressable Isolator Module every after 20 detectors / devices for Isolating short /loose circuits with automatic resetting arrangement. Isolator Base can also be proposed, however in that case needs to be considered with each detector & module. The device shall have an LED which shall blink in normal state & get steady on activation to monitor the heath status of the device. Addressing shall be with user friendly rotary decimal switches. Module shall be supplied with mounting plate and other necessary accessories. (Make : Honeywell - Notifier / Siemens - Cerberus (Fire Finder) / JCI )
Supply, Installation, Testing & Commissioning of UL listed and FM approved Intelligent addressable Class X type (Style 7), Mini Monitor Module with built in dual isolator, polarity insensitive, Tri colour LED for status (Green for Normal, Yellow for Faulty and RED for activation), Operating Temp and RH: 0-49degC and <=95%. Module shall have in-built isolator for better reliability, circuit integrity and advanced fault finding. Manufacturers not having in-built Isolator feature shall provide separate Isolator before and after every Module to comply the same without any extra cost. (For Sprinkler Flow Switches and door holders) and other necessary accessories. (Make : Honeywell - Notifier / Siemens - Cerberus (Fire Finder) / JCI)
UL listed and FM approved Intelligent addressable Class X type (Style 7), Manual Pull Station Single Action, Shock and Vibration Resistant, with built in dual isolator, polarity insensitive, Tri colour LED for status (Green for Normal, Yellow for Faulty and RED for activation), T-45 Key Reset lockset for easy maintenance, Operating Temp and RH: 0-49degC and <=95%. MCP shall have in-built isolator for better reliability, circuit integrity and advanced fault finding. Manufacturers not having in-built Isolator feature shall provide separate Isolator before and after every MCP to comply the same without any extra cost. feature etc. including connections as per specifications etc. complete as required. (Make : Honeywell - Notifier / Siemens-Cerberus / Esser)
Supply, Installation, Testing & Commissioning of UL Listed Sounder cum Strobe rated at 75 dBA @ 3m for Audible annunciation and 75cd flashing at 1 Hz for visual indication. including connections as per specifications etc. complete as required. (Make : Honeywell - Notifier / Siemens - Cerberus (Fire Finder) / JCI)
Supply, Installation, Testing & Commissioning of 24V DC 3A Switching mode power supply unit with PWM controller and MOSFET based design. Input voltage 180-265V AC, frequency 45-60 Hz, provided with transient surge protection(Varistor). To provide external power supply for PACP Note: To be installed in the safe zone or non-hazardous area and other necessary accessories.
Supply and laying of following sizes of 1.1kv grade 950 Deg. mica tape wrapped temperature with standing XLPE insulation armoured FRLS inner sheath & Outer sheath grade fire survival cable with copper conductor multistrand cable with ISI markings of approved make and quality, cable are required to be laid on wall, base bracket fitted onto wall / ceiling and necessary clamps / hardware's etc. all complete and the rate for such clamps and with all accessories as required as per site conditions. Supply and laying of 2Cx1.5 sq. mm (For fire alarm).
SUB HEAD -1 : PUBLIC ADDRESS (PA) SYSTEM
Supply, installation, testing and Commissioning of 6 Zone system controller with required all accessories.
Supply, installation, testing and Commissioning of 6 Zone Router with required all accessories.
Supply, installation, testing and Commissioning of 6 Zone Call station with required all accessories.
Supply, installation, testing and Commissioning of 6 Zone Call station extension keypad with required all accessories.
Supply, installation, testing and commissioning of Booster Amplifier for PA system with RMS output (actual) 480 W as per technical specification with indicating lamp, mounting base and all other mounting accessories complete with required all accessories.
Supply, installation, testing and commissioning of Ceiling Speaker with max SPL1M/1W 96dB . Frequency response of 80Hz-20KHz with a dispersion angle of 160 deg. The speaker should have tapping's at 6W / 3W. with required all accessories.
Supply, installation, testing and commissioning of 6W Wall mount with max SPL1M/1W 96dB . Frequency response of 160Hz-20KHz. The speaker should have tapping's at 6W/3W. with required all accessories.
Supply and laying of following sizes of 1.1kv grade 950 Deg. mica tape wrapped temperature with standing XLPE insulation armoured FRLS inner sheath & Outer sheath grade fire survival cable with copper conductor multistrand cable with ISI markings of approved make and quality, cable are required to be laid on wall, base bracket fitted onto wall / ceiling and necessary clamps / hardware's etc. all complete and the rate for such clamps and with all accessories as required as per site conditions. Supply and laying of 2Cx1.5 sq. mm (For fire alarm).
Supply and fixing for the surface /recessed / concealed PVC FRLS Medium duty conduit of thickness not less than 2mm conform to I.S. with all necessary conduit accessories such as junction boxes bends, couplings etc. 25mm Dia. Conduit.
Supply, installation, testing and commissioning of Wall mount 19", 15U / 650MMD 1 SECN with front glass door with cam lock, (1) PDU 6x15Aamp and 1.5meter feed cable and 3 pin plug, (1) shelf 255m, (2) Fan 203v 90 cfm, Hardware pkt of 20 (Assembled) with required all accessories. (Make: APW/ VALRACK/ NETRACK.)
Description of Work / Item(s)
Amount
DEMOLITION/DISMANTLING
Removal of existing Stone slab flooring fixed over the earth at site
Removal of Tree - Up to 1m Perimeter
Removal of Tree - Up to 1m to 2m Perimeter
Removal of Tree - Up to 2m to 3m Perimeter
Removal of Tree - Above 3 m Perimeter
PILING WORK Mobilisation of pile rig and its all related equipment's brought to site, installation and boring of truly vertical bored cast in situ Reinforced cement concrete piles of Grade M30 of specified diameter and specified depth below the cut-off level at each location based on the sequence of operations as directed by the Engineer-in-charge., to carry a safe working load not less than specified, by Direct Mud Circulation Method (using bentonite clay of required density). The rate shall inclusive of all design of mix pile accessories, temporary casing pipe, bentonite solution of 10% of concrete with required density with all labour charges, transportation, plant and machinery, hire and fuel charges for tools and plants, materials, shifting of plant and equipment's one place to another place as per site condition, lead & lifts, but excluding the cost of steel and fabrication reinforcement grills etc., complete as directed by the Engineer -In-Charge. Dismantling / trimming the pile concrete above cut-off level, cleaning the debris, removal of slush and carting away the same from the site including loading and unloading. The pile should be terminated at the appropriate founding level. (Pile shall be measured from the founding level to the bottom of the pile cap.) The Design Mix has to be got approved by the Engineer-In-Charge before commencement of work. Notes: The grade of concrete to be used for Piling shall be M30. The Min. Cement content shall be 400 Kg/Cum. If the admixture is added then the cement content may be reduced up to 360kg/Cum (as per IS 2911-Part 1/Sec 2-2010). Design mix shall be get prior approval from structural consultant before execution.
900mm dia. Pile
Extra for socketing of 1.5 times of dia of the pile on hard rock as directed by the Engineer-in-charge. 900mm dia. Pile
Supply and conducting Vertical load testing of piles in accordance with IS 2911-2013 including installation of loading platform and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of Engineer in-charge. Note: After testing and unloading of the superimposed load placed for the test, the pile should be chipped off 1metre below the ground level.
Initial load test - 900mm dia. Pile
Routine load test - 900mm dia. Pile
Supply Conducting Pile integrity tests (PIT) on the piles under each cluster by using a 6 lbs nylon tipped hand held hammer, gluing sensitive accelerometer on top of the pile by petro wax or petroleum jelly after making the pile head smooth and even by disc grinder, providing stage wise and final report along with relevant conclusions etc., as directed by Client / Engineer-in-charge. as per latest IS-2911. 900mm dia. Pile
Supplying, fabricating and fixing of Fe 500 grade steel in position of steel Reinforcement for all RCC work with Thermo Mechanically Treated Bars (TMT) conforming to IS 1786 of latest version according to drawings and binding the reinforcement with 18 gauge double fold GI binding wire and providing Concrete / PVC cover blocks to maintain the cover as required. Rate to include all bending, tying grills, placing, transportation, lead & lifts, tools & plants, fuels, all materials, labour charges, wastages, laying at all levels, fixing in position, cost of cover blocks, etc. as complete with all respects complying with relevant standard specification, as directed by the Engineer-in-charge. Note: The rate shall include for wastages. The work should conform to IS 1786 of BIS
EXCAVATION
Same as item no.3.01 0 to 2m depth.
Same as item no.3.01 2 to 3m depth.
Same as item no.3.01 3 to 4m depth.
Same as item no.3.01 4 to 5m depth.
Same as item no.3.01 STP
Same as item no.3.01 FFT & PUMP
Supplying and filling with approved Quarry/Crusher dust at the areas wherever required below ground level in layers not exceeding 150mm thick, including levelling, well saturating with water, consolidating and ramming etc., complete. Rate to include loading, unloading and transportation etc., complete and all as per direction of Engineer-in-charge.
Same as item no.3.08 sub structure
Same as item no.3.08 FFT & pump
Same as item no.3.08 STP
Back filling with available Excavated earth in foundation, layers not exceeding 300 mm thick up to specified depth, breaking clods, watering & consolidating and ramming etc., complete as per direction of Engineer-in-charge. Note: Approved excavated soil shall be used and remaining soil shall be disposed away from site premise. sub structure
Filling with approved (surplus) Excavated Earth available at site in foundations, basement and the areas wherever required in layers not exceeding 150mm thick, up to specified depth, including levelling, well saturating with water, consolidating and ramming etc., complete. Rate to include loading, unloading and transportation etc., complete and all as per direction of Engineer-in-charge. sub structure
Conveyance of Excavated surplus Earth and debris by lorry /tipper with an average lead of 12km entirely within city limits including loading and unloading etc. Complete and all as per direction of Engineer-in-charge. sub structure
ANTI-TERMITE TREATMENT
Providing Pre-construction Anti - termite treatment and creating a chemical barrier of "Bayer Cropscience" make or best approved quality to the building by injecting chemical emulsion of required concentration under grade slab and grade beam and below the ground level as well as outside all-round the building at plinth level etc. as per the instructions of manufacturer and as directed by the Engineer-in-charge. The treatment shall be carried out strictly in accordance with the technical specification and conforming to IS 6313 or equivalent BS specification. The chemical to be used as insecticide for the treatment shall be made up of organic base products. The application shall be diluted with water to get required emulsion and strictly in accordance with the manufacturer’s specification. The work should be carried out by an approved and registered specialist pest control agency only. Tenderer to furnish the name of the proposed specialist firm. A 10 years post application guarantee against defects shall be furnished by the main Contractor. Note : 1. Anti-termite chemical shall be made up of organic base. 2. Horizontal plan area at ground floor level of the building will be measured and paid. The chemical to be used for the treatment and concentration of the chemical solutions should be as laid down in IS - 6313 Part II. as complete with all respects complying with relevant standard specification, as directed by the Engineer-in-charge.
Same as item No. 4.01 Sub-structure
Same as item No. 4.01 Pump room & FFT
Providing and applying of Post constructional anti-termite treatment of "Bayer Cropscience" make or best approved quality for Superstructure and outer peripheral as per detailed specification and as per direction of Engineer-in-charge. Note: 1.Anti-termite chemical shall be made up of organic base products. 2. Horizontal plan area at all floor level of the building will be measured and paid.
PLAIN CEMENT CONCRETE
Providing and laying Plain Cement Concrete 1:4:8 (1 Portland pozzolona cement : 4 of coarse sand : 8 of hard broken stone jelly) using coarse graded aggregate of 40 mm for levelling course under pile caps, steps, walls, raft, retaining wall, drains, platform etc. including all materials, labour charges, wastages, mixing, curing compaction, transportation, necessary lead and lifts etc. as complete with all respects complying with relevant standard specification, as directed by the Engineer-in-charge.
Same as item no 5.01 At Sub-structure
Same as item no 5.01 FFT & pump
Same as item no 5.01 STP
Providing and laying Plain Cement Concrete 1:4:8 (1 Portland pozzolona cement : 4 of coarse sand : 8 of hard broken stone jelly) using coarse graded aggregate of 40 mm for levelling course under flooring etc. including all materials, labour charges, wastages, mixing, curing compaction, transportation, necessary lead and lifts etc. as complete with all respects complying with relevant standard specification, as directed by the Engineer-in-charge. At Ground floor
REINFORCED CEMENT CONCRETE
Providing and laying M30 Design Mix for all Reinforced cement concrete using ordinary Portland cement of grade 53 from approved manufacturer, Coarse Sand, 20 mm and down graded size coarse aggregates, necessary approved admixtures as per requirement for the following RCC members of all shapes, including necessary centering, shuttering and excluding reinforcement. Design mix shall be get prior approval from structural consultant before execution. Rate to include all designing the mix, batching plant, mechanical mixing, transporting and placing at all levels, leads, lifts, tools & plants, fuels, all materials, labour charges, wastages, laying, pumping the concrete to all levels, providing sleeves / openings in RCC slabs, compaction by vibrator, curing etc., complete with all respects complying with relevant standard specification and as per direction of Engineer- in- charge. Minimum cement content 360 kg/Cum. Note 1: Part of cement can be substituted with ground granulated blast furnace slag (GGBS) to a maximum of 25%. The physical and chemical properties of GGBS shall conform to IS: 12089-1987 (Reaffirmed 2008). Uniform blending with cement to be ensured in accordance with clauses 5.2 and 5.2.1 of IS:456-2000. Note 2: Quantity of cementitious material considered in this item is @360 kg/cum (270kg OPC + 90kg GGBS). Alternately Portland pozzolona cement with minimum 25% fly ash content can be used instead of Ordinary Portland Cement and GGBS. Note 3: Water cement ratio in the concrete mix shall not exceed 0.45.
Same as item no 6.001 RC Wall (FFT, Pump room)
Same as item no 6.001 RC Wall (sump)
Same as item no 6.001 RC Base Slab (FFT, Pump room)
Same as item no 6.001 RC Base Slab
Same as item no 6.001 RC Beam
Same as item no 6.001 Cover Slab (FFT, Pump room)
Same as item no 6.001 Cover Slab (Sump)
Providing and laying M35 Design Mix for all Reinforced cement concrete using ordinary Portland cement of grade 53 from approved manufacturer, Coarse Sand, 20 mm and down graded size coarse aggregates, necessary approved admixtures as per requirement for the following RCC members of all shapes, including necessary centering, shuttering and excluding reinforcement. Design mix shall be get prior approval from structural consultant before execution. Rate to include all designing the mix, batching plant, mechanical mixing, transporting and placing at all levels, leads, lifts, tools & plants, fuels, all materials, labour charges, wastages, laying, pumping the concrete to all levels, providing sleeves / openings in RCC slabs, compaction by vibrator, curing etc., complete with all respects complying with relevant standard specification and as per direction of Engineer- in- charge. Minimum cement content 380 kg/Cum. Note 1: Part of cement can be substituted with ground granulated blast furnace slag (GGBS) to a maximum of 25%. The physical and chemical properties of GGBS shall conform to IS: 12089-1987 (Reaffirmed 2008). Uniform blending with cement to be ensured in accordance with clauses 5.2 and 5.2.1 of IS:456-2000. Note 2: Quantity of cementitious material considered in this item is @380 kg/cum (285kg OPC + 95kg GGBS). Alternately Portland pozzolona cement with minimum 25% fly ash content can be used instead of Ordinary Portland Cement and GGBS. Note 3: Water cement ratio in the concrete mix shall not exceed 0.45.
Same as item no 6.009 Pile Cap
Same as item no 6.009 Grade Beam
Same as item no 6.009 RCC Wall
Shear Wall
At Ground floor
At first floor
At second floor
At Third floor
At Forth floor
At Fifth floor
At Sixth floor
At terrace & headroom
Column
At Ground floor
At first floor
At second floor
At Third floor
At Forth floor
At Fifth floor
At Sixth floor
At terrace & headroom
Pump room headroom
Roof Beam
At Ground floor
At first floor
At second floor
At Third floor
At Forth floor
At Fifth floor
At Sixth floor
At terrace & headroom
At Ground Floor Double high
At Forth Floor Double high
Pump room headroom
Roof slab
At Ground floor
At first floor
At second floor
At Third floor
At Forth floor
At Fifth floor
At Sixth floor
At terrace & headroom
At Ground Floor Double high
At Forth Floor Double high
Pump room headroom
Sill, Lintels & Sunshades
At Ground floor
At first floor
At second floor
At Third floor
At Forth floor
At Fifth floor
At Sixth floor
At terrace & headroom
Staircase Waist Slab
At Ground floor
At first floor
At second floor
At Third floor
At Forth floor
At Fifth floor
At Sixth floor
At terrace & headroom
pump room
RC Fin
At Ground floor
At first floor
At second floor
At Third floor
At Forth floor
At Fifth floor
At Sixth floor
At terrace & headroom
Inverted Beam (Mass Concrete)
At Ground floor
At first floor
At second floor
At Third floor
At Forth floor
At Fifth floor
At Sixth floor
At terrace & headroom
Parapet Coping Beam
At Terrace Floor & Headroom
At Pump room Headroom
Over Head Tank
RC Wall at Water tank
RC Beam at Water tank
RC Slab at Water tank
PT BEAM: Providing and laying M40 Design Mix for all Reinforced cement concrete using ordinary Portland cement of grade 53 from approved manufacturer, Coarse Sand, 20 mm and down graded size coarse aggregates, necessary approved admixtures as per requirement for the following RCC members of all shapes, including necessary centering, shuttering and excluding reinforcement. Design mix shall be get prior approval from structural consultant before execution. Rate to include all designing the mix, batching plant, mechanical mixing, transporting and placing at all levels, leads, lifts, tools & plants, fuels, all materials, labour charges, wastages, laying, pumping the concrete to all levels, providing sleeves / openings in RCC slabs, compaction by vibrator, curing etc., complete with all respects complying with relevant standard specification and as per direction of Engineer- in- charge. Minimum cement content 380 kg/Cum. Note 1: Part of cement can be substituted with ground granulated blast furnace slag (GGBS) to a maximum of 25%. The physical and chemical properties of GGBS shall conform to IS: 12089-1987 (Reaffirmed 2008). Uniform blending with cement to be ensured in accordance with clauses 5.2 and 5.2.1 of IS:456-2000. Note 2: Quantity of cementitious material considered in this item is @380 kg/cum (285kg OPC + 95kg GGBS). Alternately Portland pozzolona cement with minimum 25% fly ash content can be used instead of Ordinary Portland Cement and GGBS. Note 3: Water cement ratio in the concrete mix shall not exceed 0.45.
At Ground floor
At first floor
At second floor
At Third floor
At Forth floor
At Fifth floor
At Sixth floor
At Forth Floor Double high
Supplying and fixing of Precast slab RCC 1:2:4 (1 ordinary Portland Cement : 2 coarse Sand : 4 coarse Aggregate) for the following thickness using 20mm size hard broken stone jelly including the cost of moulding, labour charges, materials, finishing smooth on exposed surfaces, curing, transporting to the site, lead & lifts fixing in position, water tight pointing, etc. complete but excluding the cost of steel reinforcement and as directed by the Engineer-In-Charge. Rate to include all batching plant, mechanical mixing, transporting and placing at all levels, leads, lifts, tools & plants, fuels, all materials, labour charges, wastages, laying, pumping the concrete to all levels, compaction by vibrator, finishing smooth on exposed surfaces, fixing in position, water tight pointing, curing etc. as complete with all respects complying with relevant standard specification, as directed by the Engineer-in-charge.
5th Floor
Sixth Floor
Terrace
Terrace
POST TENSIONING WORKS PT Slab & PT Beam Design and execution of post tensioning work, including decoiling, the strands, cutting to the required lengths, supplying, laying of HT strands sheathing (GI corrugated ducts 0.3mm thick) jointing with couplers and inserting the strands, profiling, fixing live end anchorages, including supply of stressing anchorages, suitable for 5-5 & 5-4 tendons, grout vents, making dead end anchorages, including flowering the strands, fixing tendon support bars, supervising the fixing of anti bursting reinforcement, stressing the cables, end trimming, grouting the cables, with cement slurry, mixed with admixtures with required tools, plants, and machineries, and consumables etc. (Shuttering, concreting & reinforcement steel shall be paid under respective items) at all heights including all leads, lifts, coordination, with the post- tensioning agency, preparation of drawings, obtaining approval from the Employer / Architect etc. Rate to include providing water, power, cement and admixture for grouting, packing of sheathing and anchorages blockings, filling of recess pockets after stressing using grouts (cement slurry mixed with approved admixtures) including providing access to post tensioning at all heights including all leads, lifts etc., all complete and as approved and as directed by the Employer / Architect but excluding shuttering, concreting & reinforcement steel which shall be payable under respective items separately. All floors
MASONRY WORKS General Notes for All Masonry Related Works: 1.Portland pozzolona cement with minimum 25% fly ash content should be used in masonry related works.
C.C Solid Block Work - 200 mm Providing and constructing the masonry block work by using Precast cement concrete solid blocks of size 400 x 200 x 200mm having minimum compressive strength not less than 70kg/cm2 in cement mortar 1:6 (1 Portland pozzolona cement : 6 coarse sand) laid to line and levels at all levels etc. Rate including all leads and lifts, wetting the blocks properly by immersing in water before laying in foundation, plinth & superstructure. Rate shall include for staging & scaffolding, raking out joints, curing. complete as per particular specifications, drawings and direction of Engineer-in-Charge. NOTE: The cement concrete blocks shall contain minimum of 40% fly ash by volume of blocks.
At Ground floor
At first floor
At second floor
At Third floor
At Forth floor
At Fifth floor
At Sixth floor
At terrace headroom
At terrace Parapet wall
C.C Solid Block Work - 100 mm Providing and Constructing the masonry work by using Precast cement concrete solid blocks of size 400 x 100 x 200mm having minimum compressive strength not less than 70kg/cm2 in cement mortar 1:4 (1 Portland pozzolona cement : 4 coarse sand) laid to line and levels at all levels etc. Rate including all leads and lifts, wetting the bricks properly by immersing in water before laying in foundation, plinth & superstructure. Rate shall include for staging & scaffolding, raking out joints, curing. complete as per particular specifications, drawings and direction of Engineer-in-Charge. NOTE: The cement concrete blocks shall contain minimum of 40% fly ash by volume of blocks.
At Ground floor
At first floor
At second floor
At Third floor
At Forth floor
At Fifth floor
At Sixth floor
At terrace & headroom
Fly Ash Brick Work Providing and constructing fly ash brick work for staircase steps of suitable tread and riser with best quality chambered, table moulded burnt bricks with minimum compressive strength of 50 kg/cm2 in CM 1:5 (1 cement : 5 coarse Sand) laid to line and levels at all levels etc. Rate including all leads and lifts, wetting the bricks properly by immersing in water before laying. Rate shall include for staging & scaffolding, raking out joints, curing., complete as directed by the Engineer-in-charge.
At Pump Room
At Ground floor
At first floor
At second floor
At Third floor
At Forth floor
At Fifth floor
At Sixth floor
At terrace & headroom
JOINERY WORKS
Insulated Hollow metal fire doors Providing and fixing of Medium Duty Shakti Hormann hollow metal fire rated doors as per IS 3614: 2021, for 120min integrity & 30min. insulation. Pressed galvanized steel confirming to IS 277 with the following specification. Recommended fire door shall be tested as per IS/ISO 3008-1 & IS/ ISO 834-1, from Exova/TBW/CBRI approved lab. Labelled fire doors shall be with fire rated hardware and vision panel all as a complete assembly. Proper label confirming the type of door and the hourly rating is mandatory. Door frame shall be step rebate grooved profile of size 125 x 75mm made out of 1.20mm (18gauge) minimum thick galvanized steel sheet. Frames shall be mitered and field assembled with self tabs. Frames to have in-build grooved sealing system for taking fire rated seals. All provision should be mortised, drilled and tapped for receiving appropriate hardware. Frames should be provided with back plate bracket and anchor fasteners for installation on a finished plastered masonry wall opening. Frames shall be filled with fire rated puff. Door leaf shall be 60mm thick fully flush double skin step design door, insulated with or without vision lite. Door leaf shall be manufactured from 1.2mm (18guage) minimum thick galvanised steel sheet. The internal construction of the door should be rigid reinforcement pads for receiving appropriate hardware. The infill material shall be 120kg high density mineral wool insulation material. Intumescent seals 15 x 1.5mm to be provided. All doors shall be factory prepped for receiving appropriate hardware and provided with necessary reinforcement for hinges, locks, and door closers. The edges should be interlocked with a bending radius of 1.4mm. For pair of doors integrated astragals has to be provided on the meeting stile for both active and inactive leaf. Vision lite wherever applicable should be provided for 6mm clear borosilicate fire rated glass as per manufacturers recommendation with a clip-on arrangement. Door and frames shall be finished Pure Polyester Powder coated and shall have passed minimum 500 hours of salt spray test. Rate shall include supply and installation of frame, shutter as a complete assembly, including smoke seals & glass with tapes and hardware set schedule below; 120 Mins Fire Rated Insulated Door Single leaf of size 1200 x 2400mm with vision panel 200 x 300mm. 1.5 Knl, Ball bearing hinges size 4"x3.5"x3mm, SSS - 4 nos 2.Single point surface panic latch, XDB5760SV, Silver finish - 1 no 3.External lever handle, 1185, with half cylinder, Silver Finish - 1 no 4.Surface door closer HDC 35, EN 3-5 with slide arm, Silver finish - 1 no 5.Intumescent seal 15 x 1.5mm for insulated door - 6 Rmt 6.Fire rated seal for grooved frame profile C421 EPDM Black - Hormann - 6 Rmt All Floors
Un-Insulated Hollow metal fire doors (Powder coated) Providing and fixing of Medium Duty Shakti Hormann hollow metal fire rated doors as per IS 3614: 2021, for 120min integrity only. Pressed galvanized steel confirming to IS 277 with the following specification. Recommended fire door shall be tested as per IS/ISO 3008 & IS/ ISO 834-1, from Exova/TBW/CBRI approved lab. Labelled fire doors shall be with fire rated hardware and vision panel all as a complete assembly. Proper label confirming the type of door and the hourly rating is mandatory. Door frame shall be single rebate grooved profile of size 125 x 55mm made out of 1.20mm (18gauge) minimum thick galvanized steel sheet. Frames shall be mitered and field assembled with self tabs. Frames to have in-build grooved sealing system for taking fire rated EPDM seals. All provision should be mortised, drilled and tapped for receiving appropriate hardware. Frames should be provided with back plate bracket and anchor fasteners for installation on a finished plastered masonry wall opening. Frames shall be filled with fire rated puff. Door leaf shall be 46mm thick fully flush double skin door, sandwiched panel un-insulated with or without vision lite. Door leaf shall be manufactured from 1.2mm (18gauge) minimum thick galvanised steel sheet. The internal construction of the door should be rigid reinforcement pads for receiving appropriate hardware. The infill material shall be honeycomb core. All doors shall be factory prepped for receiving appropriate hardware and provided with necessary reinforcement for hinges, locks, and door closers. The edges should be interlocked with a bending radius of 1.4mm. For pair of doors integrated astragals has to be provided on the meeting stile for both active and inactive leaf. Vision lite wherever applicable should be provided for 6mm clear borosilicate fire rated glass as per manufacturers recommendation with a clip-on arrangement. Door and frames shall be finished Pure Polyester Powder coated and shall have passed minimum 500 hours of salt spray test. Rate shall include supply and installation of frame, shutter as a complete assembly, including smoke seals & glass with tapes and all hardware schedule below; 120 Mins Fire Rated Door Double leaf of size 1800 x 2400mm with vision panel 200 x 300mm with hardware set below, 1.5 Knl, Ball bearing hinges size 4"x3"x3mm, SSS - 8 nos 2.Mortise Dead lock, H4, 55 BS/8mm, SSS finish - 1 nos 3.Euro profile 5 pin cylinder 5702, 70mm Key x Key, NP finish. - 1 nos 4.Escutcheons for euro profile cylinder SSS - 1 pair 5.Pull handle D type PD12, 25 dia, CTC 300mm, back to back, with extended spindle, SS 304, SSS Finish - 2 pair 6.Surface door closer, HDC03, EN2/3 & 4 with standard arm, Silver finish - 2 pair 7.Concealed flush bolt set RB10 Flush Bolt L=300mm & L=600 - 1 set 8.Fire rated seal for grooved frame profile C421 EPDM Black - Hormann - 6 Rmt All Floors
Same item no 11.02,120 Mins Fire Rated Door Double leaf (Un-Equal) of size 1500 x 2400mm with vision panel 200 x 300mm with hardware set below, 1.5 Knl, Ball bearing hinges size 4"x3"x3mm, SSS - 8 nos 2.Mortise Dead lock, H4, 55 BS/8mm, SSS finish - 1 nos 3.Euro profile 5 pin cylinder 5702, 70mm Key x Key, NP finish. - 1 nos 4.Escutcheons for euro profile cylinder SSS - 1 pair 5.Pull handle D type PD12, 25 dia, CTC 300mm, back to back, with extended spindle, SS 304, SSS Finish - 2 pair 6.Surface door closer, HDC03, EN2/3 & 4 with standard arm, Silver finish - 2 pair 7.Concealed flush bolt set RB10 Flush Bolt L=300mm & L=600 - 1 set 8.Fire rated seal for grooved frame profile C421 EPDM Black - Hormann - 6 Rmt All Floors
Same item no 11.02,120 Mins Fire Rated Door single leaf (Un-Equal) of size 1050 x 2400mm with vision panel 200 x 300mm with hardware set below, 1.5 Knl, Ball bearing hinges size 4"x3"x3mm, SSS - 4 nos 2.Mortise Dead lock, H4, 55 BS/8mm, SSS finish - 1 nos 3.Euro profile 5 pin cylinder 5702, 70mm Key x Key, NP finish. - 1 nos 4.Escutcheons for euro profile cylinder SSS - 1 pair 5.Pull handle D type PD12, 25 dia, CTC 300mm, back to back, with extended spindle, SS 304, SSS Finish - 1 pair 6.Surface door closer, HDC03, EN2/3 & 4 with standard arm, Silver finish - 1 pair 7.Fire rated seal for grooved frame profile C421 EPDM Black - Hormann - 6 Rmt All Floors
Same item no 11.02,120 Mins Fire Rated Door Double leaf (Un-Equal) of size 1200 x 1500mm (shall have frame all-around door opening) with vision panel 150 x 750mm with hardware set below, 1.5 Knl, Ball bearing hinges size 4"x3"x3mm, SSS - 6 each 2.Mortise shaft lock, H7, 57 BS, SSS finish - 1 nos 3.Flush pull handle CH 120S, 120mmx40mm, sss - 2 each 4.Fire rated seal for grooved frame profile C421 EPDM Black - Hormann - 6 Rmt All Floors
Non-fire rated Hollow metal doors Providing and fixing of Standard duty Shakti Hormann Hollow metal doors confirming to IS 16074 & IS 4351 made of pressed galvanized steel confirming to IS 277 with the following specification. Doors shall be with vision glass and louver as a part of complete assembly. Door frame shall be single rebate profile of size 100 x 57mm made out of minimum 1.20mm (18gauge) thick galvanized steel sheet. Frames shall be mitered only. Frames shall be field assembled with self tabs. Bolted & butted joints are not acceptable. Frames to have in-build grooved sealing system for taking appropriate seal. All provision should be mortised, drilled and tapped for receiving appropriate hardware. Frames should be provided with back plate bracket and anchor fasteners for installation on a finished plastered masonry wall opening. once frames installed it should be grouted with non fire rated PUF. Door leaf shall be 46mm thick fully flush double skin door, with or without vision lite. Door leaf shall be manufactured from minimum 0.8mm (22guage) thick galvanised steel sheet. The internal construction of the door should be rigid reinforcement pads for receiving appropriate hardware. The infill material shall be resin bonded honeycomb core. The edges should be interlocked with a bending radius of 1.4mm. For pair of doors integrated astragals has to be provided on the meeting stile for both active and inactive leaf. Vision lite wherever applicable should be provided a clip-on arrangement. Glass shall be minimum 4mm clear toughened glass with suitable gaskets as per manufacturers recommendation with a clip-on arrangement. All doors and frames shall be finished Pure Polyester Powder coated and shall have passed minimum 500 hours of salt spray test. Rate shall include supply and installation of frame, shutter as a complete assembly. All hardware, seals & glass including tapes. Vision lite wherever applicable should be 5mm clear toughened glass as per manufacturers recommendation with a clip-on arrangement. Non-Fire Rated Door Double leaf of size 1200 x 1500mm (shall have frame all-around door opening) with Louver 250mm x300mm with hardware set below, 1.5 Knl, Ball bearing hinges size 4"x3"x3mm, SSS - 6 each 2.Mortise shaft lock, H7, 57 BS, SSS finish - 1 nos 3.Flush pull handle CH 120S, 120mmx40mm, sss - 2 each 4.Fire rated seal for grooved frame profile C421 EPDM Black - Hormann - 6 Rmt All Floors
Same item no 11.06, Non-Fire Rated Door Double leaf (Un-Equal) of size 1350 x 2400mm with hardware set as below, 1.5 Knl, Ball bearing hinges size 4"x3"x3mm, SSS - 8 nos 2.Mortise Dead lock, H4, 55 BS/8mm, SSS finish - 1 nos 3.Euro profile 5 pin cylinder 5702, 70mm Key x Key, NP finish. - 1 nos 4.Escutcheons for euro profile cylinder SSS - 1 pair 5.Pull handle D type PD12, 25 dia, CTC 300mm, back to back, with extended spindle, SS 304, SSS Finish - 2 pair 6.Surface door closer, HDC03, EN2/3 & 4 with standard arm, Silver finish - 2 pair 7.Concealed flush bolt set RB10 Flush Bolt L=300mm & L=600 - 1 set All Floors
Same item no 11.06, Non-Fire Rated Door Double leaf (Un-Equal) of size 1200 x 2400mm with hardware set as below, 1.5 Knl, Ball bearing hinges size 4"x3"x3mm, SSS - 8 nos 2.Mortise Dead lock, H4, 55 BS/8mm, SSS finish - 1 nos 3.Euro profile 5 pin cylinder 5702, 70mm Key x Key, NP finish. - 1 nos 4.Escutcheons for euro profile cylinder SSS - 1 pair 5.Pull handle D type PD12, 25 dia, CTC 300mm, back to back, with extended spindle, SS 304, SSS Finish - 2 pair 6.Surface door closer, HDC03, EN2/3 & 4 with standard arm, Silver finish - 2 pair 7.Concealed flush bolt set RB10 Flush Bolt L=300mm & L=600 - 1 set All Floors
Rolling Shutter - M.S Supplying and fixing rolling shutters with grill of approved make, made of required size M.S. laths of size 80 x 1.20 mm interlocked together through their entire length and jointed together at the end by end locks mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation with rolling grills to the suitable size and shape etc. complete including the cost of providing and fixing necessary 27.5 cm long good quality wire springs grade No.2 and M.S. top cover of 1.20 mm thick for rolling shutters. Rate shall be inclusive of one coat of red oxide primer and two coats of synthetic enamel paint of approved quality and colour. VOC CONTENT ≤ 250 grams / litre. Rate including all materials, labour charges, wastages, necessary lead and lifts, transportation charges, loading, unloading, scaffolding, staging, installation charges, fuel, consumables as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge. Same as above, but size of the shutter will be 1500 x 2400.
Same item no 11.09, but size of the shutter will be 1000 x 2400.
Same item no 11.09, but size of the shutter will be 2000 x 2400.
Same item no 11.09, but size of the shutter will be 4000 x 2400.
Wooden Doors Supply and fixing in position Sal wood frame of size 125mmx75mm to wall/column with 2 coats of enamel paint (VOC content less than 50 grams per litre) over a coat of primer (VOC content less than 50 grams per litre) of approved make to detail as shown in drawing. Frame shall have 50mmx8mm wooden architrave and fixing the same using foam sealant having VOC content less than 50 grams per litre with frame anchor fastener of size 10mmx160mm of approved make. Solid flush ply (6+25+6mm) shutter of 39mm (finished) thick Single leaf with 1mm laminate of approved make, colour & shade on both sides with teak wood lipping all-round the shutter with or without vision panel. The shutters fixed with 4nos of SS double ball bearing butt hinges. Rate inclusive of all material, labour, wastages, scaffolding, scrapping, door hardware of SS Tower bolt for top & bottom, suitable mortise lock with cylinder set, door handle, door closer, door stopper with necessary SS screws of GEZE make or best approved quality., complete as per drawing and as directed by the Engineer-in-charge. Note: Supply of door Closer, mortise lock set, SS handle will be measured and paid separately under relevant item of works. Note: The Wooden Door shall be Urea Formaldehyde Free and FSI Certified. Same as above, but with 8mm thick float glass for vision panel as per drawing, size of the door - 1200 X 2400. All Floors
Same item.no :11.13, but size of the door - 1050 X 2400. All Floors
Same item.no :11.13, but 100mmx75mm of frame size and size of the door - 750 X 2100. All Floors
Same item.no :11.13, but with 10mm thick toughened glass for vision panel on each shutter and size of the door - 1800 x 2400 mm. All Floors
Same item.no :11.13, but size of the door - 1800 x 2400 mm. All Floors
Same item.no :11.13, but shall have double action door hinges without door stopper, indicator bolt "IB 390" of Dorset make or best approved quality and attached with grab bar, size of the door 1150 x 2400 mm. Note: Supply of door Closer, grab bar will be measured and paid separately under relevant item of works. All Floors
Same item.no :11.13, but with wooden louver of size as per drawing and size of the door - 1050 x 2400 mm. All Floors
Same item.no :11.13, but 100mmx75mm of frame size and size of the door - 825 x 2400 mm. All Floors
Same item.no :11.13, but 100mmx75mm of frame size with SS tower bolt at top and indicator bolt "IB 390" of Dorset make or best approved quality and 125mm SS pull handle on both side of shutter and size of the door -750 x 2100 mm. All Floors
D type Pull Handle Supply of "D" type" stainless steel (SS-304 grade) pull handle of Geze "98163016" make or best approved quality of size 22 dia and 300 mm c/c by fixing back to back with necessary SS screws and accessories. (labour cost for fixing shall be paid under door item).All complete and direction of Engineer- in-charge. All Floors
Grab Bar cum Pull Handle Supply of stainless steel (SS-304 grade) Grab bar of Geze make or best approved quality of size 800 mm and 300mm long (1 set) with necessary SS screws and accessories. (labour cost for fixing shall be paid under door item).All complete and direction of Engineer- in-charge. All Floors
Lever Handle with Sash Lock Supply of SS 22mm dia Tubular Lever Handle "LH 9168508" with Sash Lock "ML SL 72-9168463" package of GEZE make or best approved quality with required back set, CTC-72mm, Euro profile cylinder with both side key operation, 20 SS strike plate, with necessary SS screws, nuts bolts etc.,(labour cost for fixing shall be paid under door item).All complete and direction of Engineer- in-charge. All Floors
Dead Lock Set Supply of Dead Lock package "ML DL 72-9168469" of GEZE make or best approved quality with required back set, 20mm for end, Euro profile full cylinder with both side key operation, with SS strike plate, with necessary SS screws, nuts bolts etc., (labour cost for fixing shall be paid under door item) all complete as per approval and direction of Engineer-in-charge. All Floors
Cylindrical Lock Set (Push button inside and coin slot out side) Supply of stainless steel ANSI Grade-3 (Satin Finish) Door Knob type (cylindrical lock) lock Set of Geze make suitable for door thickness range 35mm to 55mm with nuts and screws etc.(labour cost for fixing shall be paid under door item). all complete and direction of Engineer- in-charge. Note: (Push button inside and coin slot out side) All Floors
Same as above, but with 6mm thick clear float glass.
Same as above, with 6mm thick annealed glass [Visual Light Transmission (VLT) greater than (>) 25%, Solar Heat Gain Co-efficient (SHGC) less than (<) 0.4, U Value less than (<) 5 W/Sqm K] All Floors
Aluminium Glass 'N" Ventilators 'Same as above, but ventilator with fixed glass (two) shutter of 5mm thick annealed glass with mosquito mesh grill in between two shutters to form N shape all complete as per Architectural drawings and as directed by Engineer-In-charge. Note: 1. Aluminium should have not less than 10% recycled material content. 2. Glass should have 8 to 10% recycled material content. 3. Sealant should have VOC content less than (<) 100 g/litre. All Floors
Grill door - Gas bank Fabricating, supplying and fixing in position MS Grill work made out of structural steel work consisting of bars, box sections, angles, cleat as per approved design and size with neat finishing, grinding the joints properly, including fixing to wall, grouting. MS work shall be painting two coats of synthetic enamel paint (spray finish), having VOC (Volatile Organic Compound) content less than or equal to (≤) 50 grams/litre over a coat of zinc primer (having VOC less than or equal to (≤) 50 grams/litre), colour as specified & necessary scaffolding, curing, all allied civil works, labour, material etc., complete as per the drawing and directed by the Engineer-in- charge. All Floors
Grill door - Lockup cell Fabricating, supplying and fixing in position MS Grill door made out of structural steel work consisting of SOLID SECTIONS, bars, angles, cleat as per approved design and size with neat finishing, grinding the joints properly, including fixing to wall, grouting. MS work shall be painting with synthetic enamel paint (spray finish), having VOC (Volatile Organic Compound) content less than or equal to (≤) 50 grams/litre over a coat of zinc primer (having VOC less than or equal to (≤) 50 g/litre), colour as specified & necessary scaffolding, curing, all allied civil works, labour, material etc., complete as per the drawing and directed by the Engineer-in- charge. All Floors
IRON AND STEEL WORKS
Stair Case Handrail - SS Providing and fixing pre-polished Stainless steel railing of 1050 mm height using 50mm dia bent to shape for top, 40mm SS square section for vertical fixed in and 105 x 105mm SS cover plate, 20mm dia. SS post and adjustable top cap saddle and 20mm dia. Four bracing bar of SS tubular section as per approved architectural drawings and direction of the Engineer-in charge. Rate shall be inclusive of fixing the railing into the concrete surface of kerb wall with necessary hardware's, SS caps, grouting for the same etc. including final polishing, buffing at site complete (for Staircase) and as per drawing SS shall conforming of grade AISI 306. Rate including all materials, labour charges, wastages, necessary lead and lifts, transportation charges, loading, unloading, scaffolding, staging, straightening, cutting, fabricating, welding, bending to shape bolting, installation charges, fuel, consumables, tools and tackles as complete with all respects complying with relevant standard specification and as directed by the Engineer-in- charge.
Supply and fixing of Stainless Steel (SS) handrail to a height of 1050 mm from finished floor level for ramp / steps (Grade 316) consists of 50mm dia SS top rail with 50mm dia vertical connected to top rail with the help of 25mm dia SS pipe and with 2 no's of horizontal mid rails of 20 mm dia SS rods, SS base plates etc., complete (for Ramp) as per the drawing and direction of the Engineer-in-charge. Rate shall be quoted for exterior grade.
MS - LADDER Providing and fixing of MS Ladder from terrace floor to OHT as per approved design and size with neat finishing, grinding the joints clearly, including grouting and placing in position with one coat of primer (VOC less than or equal to (≤) 50 gms / litre) and 2 coats of enamel Paint (VOC less than or equal to (≤) 50 gms / litre) finishing colour as specified & necessary scaffolding, curing, all allied civil works, labour, material etc., complete as per the drawing and directed by the Engineer-in-charge. TERRACE FLOOR
MS - CHEQUERED PLATE Supply, fabrication and erection of structural steel (with 10 to 15% Recycled content) confirming to IS 2062 including 1 coats of red oxide primer & 2 coats of approved synthetic enamel paint (VOC less than or equal to (≤) 50 gms / litre ) over Steel members including all channels, supports, steel plate, anchor bolts, cross angles, brackets, etc. including grouting, welding, tools, tackles as required etc. The payment shall be made for the actual quantities measured. This item shall be operated for cable trenches, panel, DB base frames, chequered plate supports in trench, vertical tray supports and any other miscellaneous structural steel works. MV PANEL ROOM
Providing and fixing reinforcement steel including drilling of holes 12mm of size and fixing the rod using lockset compound as detailed in drawing and as directed by the Engineer-in-charge. All Floors
Providing and fixing of manhole cover made up of FRP of specified size with all allied civil work including material, labour etc., compete as directed by the Engineer-in-charge. FRP Heavy duty cover of Size 600 x 600mm
Providing and fixing of manhole cover made up of FRP of specified size with all allied civil work including material, labour etc., compete as directed by the Engineer-in-charge. FRP Medium duty cover of Size 600 x 600mm
Providing and fixing Polypropylene rungs including all allied civil work, material, labour, grouting, packing, scaffolding etc., complete as directed by the Engineer-in-charge.
FLOORING WORKS General Notes for Flooring Works: 1.Portland pozzolona cement with minimum 25% fly ash & GGBS content should be used in Flooring works. 2.All flooring item shall be inclusive of providing & removing POP protection with polythene sheet, Acid wash etc., complete. 3. Shop drawing shall be produced by the contractor for approval from architect for Granite flooring, Ceramic, Vitrified and any other kind of tile flooring before execution. 4. VOC content shall be less than (<) 65 g/litre (adhesive or grout material).
75mm thick Granolithic flooring - Service Area Providing and laying 75mm thick Granolithic flooring in panels not more than 20 sqm in plan with cement concrete 1:1.5:3 (1 Portland pozzolona cement : 1.5 coarse sand : 3 stone aggregate) by using coarse graded aggregate of 6 to 12 mm size laid monolithic with floor concrete and finished smooth with power trowel including preparation of concrete surface and form work. Unevenness in floor finish shall not exceed +2mm in one square metre area. Rate including all materials, labour charges, wastages, necessary lead and lifts, working at all levels, transportation charges, pumping, loading, unloading, preparation of surface, necessary hacking in RCC surface, power trowel, smooth finishing, fixing of screed strips, tools and plants, fuel, curing as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge.
Vitrified Tile Flooring Supplying and laying Vitrified floor tile of specified size, colour and make laid on 20mm thick base CM 1:4 (1 Portland pozzolona cement: 4 coarse sand) with a coat of cement slurry including cutting, laying in position with 3mm spacer and filling the joints by Laticrete (cementitious based) grout of matching colour, inclusive of all labour, material, wastages, preparation of base surface etc., complete at all levels as per direction of Engineer-in-charge. Note: 1.Vitrified tiles should have 5 to 10% recycled material content. 2. VOC content shall be less than (<) 65 g/litre (adhesive or grout material).
Anti-skid Ceramic Flooring (Toilet Area) Supplying and laying Anti skid Ceramic floor tile in toilets of specified size, specified colour and make laid on 20mm thick base CM 1:4 (1 Portland pozzolona cement: 4 coarse Sand) with a coat of cement slurry including cutting, laying in position with 3mm spacer and filling the joints by Laticrete (epoxy based) of matching colour, inclusive of all labour, material, wastages, preparation of base surface etc., complete at all levels as per direction of Engineer-in-charge. Note: 1. Anti-skid Ceramic tiles should have 5 to 10% recycled material content. 2. VOC content shall be less than (<) 65 g/litre (adhesive or grout material).
Vanity Counter Top Supplying and fixing of 18mm thick machine cut mirror polished Granite (sample of granite shall be approved by Engineer-in-charge) of required size, approved shade, colour and texture laid over 20 mm thick base C.M 1:4 (1 Portland Pozzolona cement : 4 Coarse Sand) with white cement slurry, joints treated with white cement mixed with matching pigment, epoxy touch ups, including rubbing, curing, edge moulding and polishing the edges to give high gloss finish as directed inclusive of all labour, material and wastages etc., complete at all levels. Rate shall include for base RCC Slab, providing opening of required size & shape for wash basin/sink and necessary holes for pillar taps etc. as directed by Engineer-in-charge. Black Granite Shade
Window sill, Ledge wall Top Supplying and fixing of 18mm thick machine cut mirror polished single piece Granite (sample of granite shall be approved by Engineer-in-charge) of required size, approved shade, colour and texture laid over 20 mm thick base C.M 1:4 (1 Portland Pozzolona cement : 4 Coarse Sand) with white cement slurry, joints treated with white cement mixed with matching pigment, epoxy touch ups, including rubbing, curing, edge moulding and polishing the edges to give high gloss finish as directed inclusive of all labour, material and wastages etc., complete at all levels. Black Granite Shade
Granite Flooring Supply and laying 18 mm thick machine cut mirror polished (pre-polished) Granite stone flooring in required design and pattern in linear as well as curvilinear portions of the building all complete as per architectural drawings of approved shade, quality laid on 20mm thick base in CM 1:4 (1 Portland pozzolona cement: 4 coarse Sand) and jointed with a coat of white cement slurry @ 3.3 kg/sqm, finishing the joints with white cement admixed with matching pigment including rubbing, curing and polishing etc. all complete as shown in the drawing. Rate shall include for preparation of base surface, protection the surface with POP till hand over etc., complete and as directed by the Engineer-in-charge. All Floors
Staircase tread Supply and laying of 18mm thick leather finished single piece Granite stone (sample of granite shall be approved by Engineer-in-charge) for staircase (tread) steps with approved shade, colour and texture laid on 20mm thick base CM 1:4 (1 Portland pozzolona cement: 4 coarse sand) with a coat of cement slurry @ 3.3 kg/sqm, finishing the joints with matching colour pigment, epoxy touch ups, including edge moulding, making necessary grooves/anti-skid provision, rubbing, curing etc. complete at all levels as shown in the drawing. Rate shall include for preparation of base surface, protection the surface with POP till hand over etc., complete and as directed by the Engineer-in-charge. All Floors
Staircase Riser Supply and laying of 18mm thick machine cut mirror polished (pre-polished) single piece Granite stone (sample of granite shall be approved by Engineer-in-charge) for risers of steps with approved shade, colour and texture laid on 12mm thick base CM 1:3 (1 Portland pozzolona cement: 3 coarse sand) with a coat of cement slurry @ 3.3 kg/sqm, finishing the joints with matching colour pigment, epoxy touch ups, including curing etc. as shown in the drawing. Rate shall include for preparation of base surface, protection the surface with POP till hand over etc., complete and as directed by the Engineer-in-charge. All Floors
Floor & Dado Tile - Sump & OHT Supplying and fixing Glazed tiles for floor and wall dado of specified size, white colour and approved make on 20mm tk base mortar in C.M 1:4 (1 Portland Pozzolona cement : 4 Coarse Sand), including cutting, laying in position with 3mm spacer and filling the joints with food grade grouting material by Laticrete (epoxy based) as colour specified. Rate shall inclusive of all material, labour, curing, cleaning etc., complete as directed by the Engineer-in-charge. Note: 1.Glazed tiles should have not less than 10% recycled material content. 2. VOC content shall be less than (<) 65 g/litre (adhesive or grout material).
Floor Tile - Exterior Supplying and laying 16mm tk. Exterior Grade full body homogeneous tiles (full body porcelain tile) of PAVIT make of specified size, colour and make laid on 20mm tk base CM 1:4 (1 Portland Pozzolona cement: 4 Coarse Sand) with a coat of cement slurry including cutting, laying in position with 3mm spacer and filling the joints by Laticrete (cementitious based grout) of matching colour, inclusive of all labour, material, wastages, preparation of base surface etc., complete as per direction of Engineer-in-charge. Note: 1.Vitrified tiles should have not less than 10% recycled material content. 2. VOC content shall be less than (<) 65 g/litre (adhesive or grout material). All Floors
False Flooring - 300 mm Finished Floor Height (FFH) Providing and fixing removable raised/false access flooring with system and its components of approved make for different plenum height with possible height adjustment up to 50 mm, comprising of modular load bearing floor panels supported on G.I. rectangular stinger frame work and G.I. Pedestal etc. all complete, as per the architectural drawings, as specified and as directed by Engineer-in-charge consisting of: (a) Providing at required spacing to form modular framework, pedestals made out of GI tube of thickness minimum 2 mm and 25 mm outer diameter, fully welded on to the G.I. Base plate of size 100mm x 100mm x 3mm at the bottom of the pedestal tube, G.I. pedestal head of size 75mmx75mmx3.5 mm welded with GI fully threaded stud 16mm outer diameter with two GI Check nuts screwed on the stud for level adjustment up to 50mm, locking and stabilizing the pedestal head in position at the required level. The pedestals shall be fixed to the subfloor (base) through base plate using epoxy based adhesive of approved make or the machine screw with rawl plug. (b) Stringers system in all steel construction hot dipped galvanized of rectangular size 570x20x30x0.80mm thick having holes at both ends for securing the stringers on to the pedestal head using fully threaded screws ensuring maximum lateral stability in all directions, the grid formed by the pedestal and stringer assembly shall receive the floor panel, this system shall provide adequate solid, rigid support for access floor panel, the system shall provide a minimum clear uninterrupted clearance between the bottom of the floor for electrical conduits and wiring etc. all complete as per the architectural drawings, as specified and as directed by the Engineer-in-charge. (c) Providing and fixing Access Floor panel of 600x600x33 mm medium grade Filled Steel anti static high pressure Lamination of 800H grade (FS800H). Access Floor panel shall be steel welded construction with an enclosed bottom pan with uniform pattern of 64 hemispherical cones. The top and bottom plates of Steel Gauges: top 0.6 mm and bottom 0.7 mm fused spot welded together (minimum 64 welds in each dome and 20 welds along each flange). The panel should be Corroresist epoxy coated for lifetime rust protection and cavity formed by the top and bottom plate is filled with Pyro grip non-combustible Portland cementitious core mixed with lightweight foaming compound. The access floor shall be factory finished with Anti-static High Pressure laminate with Non Warp technology up to 1mm thickness for superior adhesion and Surface flatness within 0.75mm.The panel is to withstand a Concentrated Load of 363 kgs applied on area 25mm x 25mm without collapse in the centre of the panel which is placed on four steel blocks. The panel will withstand and Uniformly Distributed Load (UDL) minimum 1650 kg/sqm and an impact load of 50kg all complete as per the approved manufacturers specification and as per the direction of Engineer-in-charge. All specification must be printed on the side of the panel to ensure the quality of the product.
Granite - Ramp: Supplying and fixing of leather finish granite for Ramp with 18mm thick of approved shade laid on 20 mm thick CM 1:4 (1 Portland pozzolona cement :4 coarse sand) over slab in all the floors including cutting the granite slab to the required size wherever necessary, including cost of granite slab, making necessary grooves/anti-skid provision, rubbing and polishing etc. complete in all respects complying with relevant standard specification and as directed by the Engineer-in-Charge. (Measurement will be taken including bearing in to walls also. The quality and colour of Granite slab shall be got approved by the Engineer-in-Charge before fixing.) Rate including all materials, labour charges, wastages, necessary lead and lifts, working at all levels, transportation charges, loading, unloading, preparation of surface, necessary hacking in RCC surface, cutting to required shape, edging, edge moulding anti skid & grooves as per drawing, tools and plants, fuel, curing, cleaning, acid wash over finished surface, protection with Gypsum / Pop layer over plastic sheet and removing the same before handing over as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge. In Ground Floor
Screed Flooring Providing and laying screed flooring 50mm thick in panels not more than 20 sqm in plan with cement concrete 1:2:4 (1 pozzolona Portland cement : 2 coarse sand : 4 coarse aggregate) by using coarse graded aggregate of 6 to 12mm size & Sand laid monolithic with floor concrete and with rough finish to receive the flooring tile including preparation of surface, levelling, curing etc. complete as directed by the Engineer-in-Charge. (for Toilet & Terrace portion) All Floors
Urinal partition - Granite Supplying and fixing machine cut mirror finished (pre-polished) granite of 18mm thick jet black granite stone table rubbed, edges rounded and polished etc. complete as per architectural drawings with all respects complying relevant standard specification and as directed by the Engineer-in-charge. All Floors
SKIRTING WORKS General Notes for Skirting Works: 1.Portland pozzolona cement with minimum 25% fly ash content should be used in Skirting works. 2.All flooring item shall be inclusive of providing & removing POP protection with polythene sheet, Acid wash etc., complete. 3. VOC content shall be less than (<) 65 g/litre (adhesive or grout material).
Vitrified tile Skirting Supply and laying Vitrified tile of 100mm high for skirting of approved sample and quality make laid in CM 1:3 (1 Portland pozzolona cement: 3 fine Sand) 12mm thick with a coat of cement slurry as shown in the drawing, finishing the joints with matching colour cement and including cleaning, chipping of walls, grooves, finish, & curing etc., complete as directed by the Engineer-in-charge. Rate shall include for preparation of base surface, protection the surface with till hand over. Rate including all materials, labour charges, wastages, necessary lead and lifts, working at all levels, transportation charges, loading, unloading, chasing of wall for flushing the tile inline with wall surface, preparation of surface, necessary hacking in RCC surface, cutting of tiles to required shape, edging, tools and plants, fuel, curing, cleaning, acid wash over finished surface, protection with Gypsum / Pop layer over Plastic sheet and removing the same before handing over as complete with all respects complying with relevant standard specification and as directed by the Engineer-in- charge. Note: Vitrified tiles should have not less than 10% recycled material content. All Floors
Granite Skirting Providing 100 mm high skirting with best quality approved granite slab of thickness not less than 18 mm, machine cut and machine high pre-polished set in Laticrete adhesive L 290 to a thick of 4mm uniformly and finishing the joints with Latapoxy SP 100 of Laticrete or equivalent make, at all levels and all as per drawing. Rate shall include for preparation of surface, with tin-oxide / high gloss factory polish. Rate also to include filleting /chamfering of the edges along with partial recessing of the skirting into masonry / gypsum wall. At Ground Floor
Granite Skirting - Staircase Supply and laying 18mm thick Granite slabs for Staircase Skirting with chamfering of approved sample & quality laid on 12mm (average) thick in CM 1:3 (1 Portland pozzolona cement: 3 fine Sand) with a coat of cement slurry as shown in the drawing, finishing the joints with matching colour cement, nosing and hand polish including cleaning, chipping of walls, grooves, finish & curing etc., complete as directed by the Engineer-in-charge. Rate shall include for preparation of base surface, protect the surface with approved material till hand over. All Floors
Diagonal Granite Skirting - Staircase Supply and laying 18mm thick Granite slabs for Staircase Skirting with chamfering of approved sample & quality laid on 12mm (average) thick in CM 1:3 (1 Portland pozzolona cement: 3 fine Sand) with a coat of cement slurry as shown in the drawing, finishing the joints with matching colour cement, nosing and hand polish including cleaning, chipping of walls, grooves, finish, & curing etc., complete as directed by the Engineer-in-charge. Rate shall include for preparation of base surface, protect the surface with approved material till hand over. All Floors
Cement Plaster Skirting Plaster Skirting : Providing cement plaster skirting up to 100 mm height, with cement mortar 1:3 (1 Portland pozzolona cement : 3 fine sand) 12mm thick smooth finishing to line and level, finished with a floating coat of neat cement etc., complete as directed by Engineer-in-charge. All Floors
WALL DADO General Notes for All Dado Works: 1.Portland pozzolona cement with minimum 25% fly ash or GGBS content should be used in Plastering works. 2.All base plastering for wall dado shall be included 150mm wide GI plaster mesh made out of galvanized iron of nominal thickness 0.35mm with a zinc coating of 120 gms/Sqm 3. Shop drawing shall be produced by the contractor for approval from architect for Granite cladding, Glazed, Vitrified and any other kind of tile cladding or dado before execution. 4. VOC content shall be less than (<) 65 g/litre (adhesive or grout material).
Wall Dado - Toilet Supplying and fixing of Glazed tile dado (wall) of specified colour and make on 15mm average thick base mortar in C.M 1:3 (1 Portland pozzolona cement : 3 fine Sand), including cutting, laying in position with 3mm spacer and filling the joints by Laticrete (epoxy based) as colour specified inclusive of all material, labour, curing, cleaning etc., complete as directed by the Engineer-in-charge. Note: Glazed tiles should have 5 to 10% recycled material content. All Floors
Granite Wall Cladding - Lift Supplying and fixing in position with 18mm thick Pre-polished Granite stone cladding for wall of approved shade, colour, design & pattern laid as per drawing on 15mm (average) thick C.M 1:3 (1 Portland pozzolona cement : 3 fine Sand) topped with white cement slurry, cutting, groove making & edge chamfering, joint filling and inclusive of all labour, material wastages etc., complete. Rate shall include for preparation of base surface, Protection the surface and acid wash during handing over etc., Complete and as directed by the Engineer-in Charge. In Ground Floor
INTERNAL AND EXTERNAL PLASTERING AND PAINTING General Notes for All Plastering Works: 1.All plastering shall be included 150mm wide GI plaster mesh made out of galvanized iron of nominal thickness 0.35mm with a zinc coating of 120 gms/Sqm (ARPITHA/Equivalent) with Galvanised nails etc., for junctions of masonry and RCC works & electrical conduiting area, packing of electrical, plumbing pipes etc. hacking at RCC surface, scaffolding, lifting etc., 2.Portland pozzolona cement with minimum 25% fly ash or GGBS content should be used in Plastering works.
Plastering - Internal Wall Providing 15mm thick cement plaster with CM 1:5 (1 Portland pozzolona cement : 5 fine Sand) for Internal wall & column surface in smooth finishing to line and level with cement rendering, rounding of all corners wherever required, including GI plaster mesh of Arpitha make for junctions of masonry and RCC works, button marking, levelling, scaffolding, curing, etc., complete as directed by the Engineer-in-charge.
At Ground floor
At first floor
At second floor
At Third floor
At Forth floor
At Fifth floor
At Sixth floor
At terrace & headroom
Plastering - Internal RC Wall/Lift Wall Providing 12 mm thick plain plastering with CM 1 : 3 (1 Portland pozzolona cement : 3 fine sand) over concrete wall surface in smooth finishing to line and level with cement rendering, rounding of all corners wherever required, including GI plaster mesh of Arpitha make for junctions of masonry and RCC works, button marking, levelling, scaffolding, curing etc., complete as directed by the Engineer-in-charge.
At pump room
At Ground floor
At first floor
At second floor
At Third floor
At Forth floor
At Fifth floor
At Sixth floor
At terrace & headroom
Plastering - External Wall Providing 15mm thick cement plaster in single coat with CM 1:5 (1 Portland pozzolona cement : 3 fine sand) for external wall surface in smooth finishing to line and level with cement rendering, rounding of all corners wherever required, including GI plaster mesh of Arpitha make for junctions of masonry and RCC works, button marking, levelling, scaffolding, curing, etc., complete as directed by the Engineer-in-charge. The rate is inclusive of forming of plaster or drip band/moulds, architectural grooves etc., as per direction of Engineer-in-charge.
At Ground floor
At first floor
At second floor
At Third floor
At Forth floor
At Fifth floor
At Sixth floor
At terrace & headroom
At terrace & headroom
Plastering - Ceiling Providing 12 mm thick plain plastering with CM 1 : 3 (1 Portland pozzolona cement : 3 fine Sand) over concrete ceiling surface (except false ceiling area only) in smooth finishing to line and level with cement rendering, rounding of all corners wherever required, including button marking, levelling, scaffolding, curing etc., complete as directed by the Engineer-in-charge.
At Pump Room
At Ground floor
At first floor
At second floor
At Third floor
At Forth floor
At Fifth floor
At Sixth floor
At terrace & headroom
At Ground floor Double high
Internal Wall Painting: Providing and applying two or more coats of Plastic emulsion paint having VOC (Volatile Organic Compound) content less than or equal to (≤) 50 grams / litre of approved make and colour for internal walls over one coat of primer and two coats of putty required to achieve smooth finish including necessary scaffolding, preparation of surface cleaning of paint stains, curing etc., complete at all levels and as directed by Engineer-in-charge. All Floors
Painting - Ceiling Providing and applying two or more coats of Plastic emulsion paint having VOC (Volatile Organic Compound) content less than or equal to (≤) 50 grams / litre of approved make and colour for internal ceiling (except false ceiling area only) one coat of primer and touch up putty if required to achieve smooth finish including necessary scaffolding, preparation of surface cleaning of paint stains, curing etc., complete at all levels and as directed by Engineer-in-charge. All Floors
Painting - Exterior wall Providing and applying two or more coats of Plastic emulsion paint having VOC (Volatile Organic Compound) content less than or equal to (≤) 50 grams / litre of approved make and colour for External Wall over one coat of primer and touch up putty if required to achieve smooth finish including necessary scaffolding, preparation of surface cleaning of paint stains, curing etc., complete at all levels and as directed by Engineer-in-charge. All Floors
Texture Painting Providing and applying two or more coats of Exterior texture paint having VOC (Volatile Organic Compound) content less than or equal to (≤) 50 grams / litre of approved make and colour for external walls, over one coat of primer after surface preparation and two or more coat of approved shade paint over a base texture coat. Rate including necessary scaffolding, preparation of surface cleaning of paint stains, curing etc., complete at all levels and as directed by Engineer-in-charge. All Floors
WATER PROOFING WORKS Note: Sub Contractors to be approved by Client/Consultant/Project Managers. A 10 years post application guarantee against defects shall be furnished by the main Contractor.
Crystalline waterproofing for lift Providing water proofing for Lift wall (Inside area) with crystallization with pressure grouting in construction joints by racking the joints as specified by the manufacturer including testing, curing etc., complete and all as per direction of Engineer-in-charge. Lift Pit
UG SUMP & STP - WATERPROOFING : For external surfaces Supplying and applying of water proofing treatment on below rafts of sump & basement, lift pile cap and walls using 4mm thick polymer modified Bituminous membrane of approved makes of either Styrene Butadiene Styrene (SBS) based or Atactic Poly-Propylene (APP) based with UV resistant, ground chemical resistant, high melting points, flexible and elastic with high adhesive strength. The membrane shall be reinforced with non woven polyester reinforcement of minimum of 180 g/sqm and reinforced with glass fibre grill of 8 g/sqm including coating with compatible primer of Bituminous base and torch application with overlap of 70 - 100 mm wherever required. The reinforcement provided shall be able to withstand the traffic flow density and after construction and shall carry a minimum guarantee period of 10 years. Cost to include laying by loose and torching the prefabricated overlap at ends. The membrane surface shall be protected with granules.
Sub-Structure area
FF. Tank & pump room
UG SUMP & STP - WATERPROOFING : For Internal Floors & walls Making “V” groove over construction joint and filling “V” groove with Quick setting material admixed with cement. Providing and fixing 15 mm dia. GI Nozzle at 1 m c/c on grid pattern over the RAFT and 1 m c/c at construction joint over the RC Wall and injection of Non Shrink Polymeric grouting compound admixed with cement slurry with 40 PSI pressure through the nozzle by pump, after injection operation is over the nozzle shall be sealed with Quick setting material admixed with cement. Providing and laying water proofing treatment to the raft slab and inner surfaces of walls of Underground sump, STP tank etc., by applying : (i) First coat of Brush bond RFX @ DFT 1mm thick of M/S. Fosroc chemicals/Pidilite industries or equivalent as per manufacturer's specification. This coat is to be air cured for 6 hours. (ii) Second coat of Brush bond RFX @ DFT 1mm thick of Fosroc chemicals or equivalent as per manufacturer's specification. This coat is to be air cured for 6 hours. Both First & Second coat together should have minimum DFT 1.5 mm thick (iii) Third coat of bond coat with Cement slurry mixed with SBR latex @ 3 litres per bag of cement applied as per manufacturers specification to get good bonding with next layer. (iv) Fourth coat of 12 mm Thick Cement Plaster in Cement mortar 1:3 (1 Portland pozzolona Cement : 3 coarse sand) with floating coat of neat cement punning both admixed with conplast X421 IC of Fosroc or Pidi Proof 101 LW of pidilite or equivalent applied before the air curing of third layer. The rate includes preparation of surface treatment, removal of dust from surface using compressed air and sealing of all joints, corners, junctions of pipes and R.C.C with polymer mixed slurry etc., all complete as per direction of Engineer-in-charge.
SWELLABLE WATER STOPPER - SUMP Supply and Fixing Swellable water stopper bar with proper adhesive component on construction joints of RCC wall and it should be protect against swelling due to any moisture presence before concreting. all complete as per direction of Engineer-in-charge.
FFT & pump room ( 3 LVL)
STP ( 3 LVL)
WATER PROOFING : TOILET SUNKEN AREA Providing water proofing system by fixing authorised water proofing agencies with Silicon based chemical coating systems as specified over the RCC slab and adjoining walls up to 300mm height from above floor level including surface preparation, applying two coats with silicon based chemical waterproofing system and covering with protective cement plaster of 20mm thick by CM 1:4 (1 Portland pozzolona cement : 4 fine Sand) admixed with water proofing compound including testing, curing etc. (for toilet sunken slabs) Note: Waterproofing to be done up to 300mm ht of walls from floor level for sunken portion and Plan area shall be the mode of measurement. All Floors
Brick bat Concrete - Toilet Toilets: Providing and laying slope making brick jelly cement concrete using broken fly ash brick bats of 40 mm in size as specified thickness, in mix 1:3:6 (1 of portland pozzolona cement : 3 of coarse sand : 6 of broken fly ash brick bats) admixed with Proofsol LWP, integral waterproofing compound@100 ml per bag of cement and a slope of 1:120, making wattas at the junctions of horizontal and vertical surfaces to a float finish, well compacted, curing for 7days etc., all complete as per direction of Engineer-in-charge. All Floors
Waterproofing inside OH Tank : Providing and laying water proofing treatment to the mother slab and inner surfaces of walls of over head water tank, Sump tank etc. by applying : (i) First coat of Brush bond RFX @ DFT 1mm thick of M/S Fosroc chemicals/Pidilite industries or equivalent as per manufacturer's specification. This coat is to be air cured for 6 hours. (ii) Second coat of Brush bond RFX @ DFT 1mm thick of Fosroc chemicals or equivalent as per manufacturer's specification. This coat is to be air cured for 6 hours. Both First & Second coat together should have minimum DFT 1.5 mm thick (iii) Third coat of bond coat with Cement slurry mixed with SBR latex @ 3 litres per bag of cement applied as per manufacturers specification to get good bonding with next layer. (iv) Fourth coat of 12 mm Thick Cement Plaster in Cement mortar 1:3 (1 portland pozzolona Cement : 3 coarse sand) with floating coat of neat cement punning both admixed with conplast X421 IC of Fosroc or Pidi Proof 101 LW of pidilite or equivalent applied before the air curing of third layer. The rate includes preparation of surface treatment, removal of dust from surface using compressed air and sealing of all joints, corners, junctions of pipes and R.C.C with polymer mixed slurry etc., all complete as per direction of Engineer-in-charge. (In Terrace Floor)
TERRACE WATERPROOFING: Providing and laying waterproofing coating on the roof slabs of the building with single component liquid polyurethane elastomeric membrane with minimum elongation of 400% and solid content 90% using Dr Fixit Flexi PU 270(i) or equivalent as per the approval of engineer-in-charge applied @ 1.5 Kg/sq-m in two or three layers over a coat of Primer using Primer PU of Dr Fixit Pidiproxy MIEP or equivalent including application of Geotextile of 150 GSM on the completed and cured surface all complete as per direction of Engineer-in-charge and manufacturers specifications. The rate includes preparation of surface, removal of dust from surface using compressed air, filling the local depressions with rich polymer mortar like Rendroc-HB2 of M/s Fosroc chemicals or equivalent and sealing of all joints, rounding of corners of slabs and walls & junctions of pipes and masonry with polymer mixed cement mortar/concrete etc., all complete as per manufacturers specifications and direction of engineer-in-charge. Note: Waterproofing to be done up to 450mm ht of walls and Plan area shall be the mode of measurement. All Floors
TERRACE WEATHERING COARSE: Providing and laying WEATHER PROOF COURSE 120mm average thick for Terrace roof slab using half bricks set in CM 1:4 (1 portland pozzolona cement : 4 coarse Sand) admixed with liquid integral water proofing compound of approved make @100ml per bag of cement with minimum thickness 65mm at the rain water outlet and a slope of 1:100, including bull marking to required slope with making wattas at the junctions of horizontal and vertical surfaces and the brick shall be placed in mortar with 20mm gap all-round and the joints shall be filled with the same cement mortar including all lead lifts, curing etc., complete as per direction of Engineer-in-charge. All Floors
Weather Tiles - Terrace Supply and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI (solar reflectance index) > 82, Solar Direct Reflectance > 0.70 and initial Emissivity > 0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick CM in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement & marble powder in ratio of 1:1, including rubbing and polishing of the surface up to 3 cuts complete, including providing skirting up to 150 mm height along the parapet walls in the same manner.
ELEVATION WORKS
Granite Wet Cladding - Elevation Supplying and fixing in position with 18mm thick Pre-polished Granite stone cladding for Elevation wall of approved shade, colour, design & pattern laid as per drawing on 15mm (average) thick C.M 1:3 (1 Portland pozzolona cement : 3 fine Sand) topped with white cement slurry, cutting, groove making & edge chamfering, joint filling and inclusive of all labour, material wastages etc., complete. Rate shall include for preparation of base surface, Protection the surface and acid wash during handing over etc., Complete and as directed by the Engineer-in Charge. Ground & First Floor
STRUCTURAL GLAZING - Elevation Designing, providing and fixing in position of structural glazing (Semi unitised system) vision panel & vision on spandrel panel for linear or curvilinear portions of the building for all heights and all levels including Structural analysis & design and preparation of shop drawings for the specified design loads conforming to IS 875 part III using colour anodized (coating thickness not less than 15 micron) Jindal or best approved quality extruded aluminium mainframe section for verticals & horizontals of suitable size shall be designed to withstand wind pressure using necessary aluminium/GI angle cleats with slots for adjusting plumb, fixed to the RCC slabs with M10 expansion of fischer fasteners . Note : 8 to 10% recycled content i)The entire structural glazing system fabrication comprising of hermetically sealed 23mm thick insulated glass (6mm thick outer heat strengthened glass of approved colour and shade with reflective soft coating +12 mm wide spacer tube + 5 mm thick an inner heat strengthened clear glass including primary and secondary seal) vision panel having properties as Visual Light Transmission (VLT) greater than (>) 25%, Solar Heat Gain Co- efficient (SHGC) less than (<) 0.4, U Value less than (<) 5 W/Sqm K, using Dowsil 995 accelerated cure for structural sealant (having VOC content less than (<) 100 g/litre) in such a way as to transfer the dead weight of the glass on to the mainframe so as to avoid undue stress on the structural sealant (having VOC content less than (<) 100 g/litre). The glazed panels after suitable curing in dust free environment will be fixed on to mainframe from the exterior (this system enables easy replacement of glass in future (if any breakage) from the outside especially in spandrel areas). ii) The grooves (12 to 16mm) will be closed with weather grade silicone sealant(having VOC content less than (<) 100 g/litre) Dowsil 789. Weather gaskets shall be of microwave cured EPDM of approved quality for water tightness, pressure equalisation & drainage and protection against fire hazard. The contractor shall ensure that the whole system uses corrosion resistant hardware's, is totally weather proof, permits necessary thermal expansion /contraction and is able to withstand relevant wind loads and as per approved architectural drawings and direction of the Engineer-in-charge.
iii) Making provision for drainage of moisture/ water that enters the curtain glazing system to make it watertight, by incorporating principles of pressure equalization, providing suitable gutter profiles at bottom (if required), making necessary holes of required sizes and of required numbers etc. complete. iv) This item includes cost of all inputs of designing, labour for fabricating and installation of aluminium grid, installation of glazed units, transport & package, double scaffolding & platform, safety net and other incidental charges including wastages etc., enabling temporary structures and services, cranes or cradles etc. as described above and as specified. v) The item also includes the cost of all mock ups at site, cost of fire stop (barrier) cum smoke seals of 120 minutes Fire Rating, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working structural glazing as specified, cleaning and protection till the handing over of the building for occupation. In the end, the Contractor shall provide a water tight structural glazing having all the performance characteristics etc. all complete as required, as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer-in-Charge. All floors
MS WORK FOR DOME STRUCTURE Steel work in built up sections such as tubular (round, square or rectangular hollow tubes etc.) or framed work (angles, channels, I beams etc.,) including cutting, hoisting, fixing in position and applying a priming coat of approved Zinc coat primer having VOC less than or equal to (≤) 250 g/litre, including welding and bolted with special shaped washers etc. complete as per direction of engineer in charge. The item also includes the cost of civil/electrical/mechanical works during the erection of MS channel work and other welding works etc. necessary at site. All floors
HUNG SHUTTER SYSTEM - OPENABLE Extra for providing and fixing of openable top Hung shutter in structural glazing over the above rate using heavy duty SS friction stay hinges of suitable size, multi-point locking cum handle etc., complete as per approved architectural drawings and direction of the Engineer-in-charge. All floors
CLEANING SUPPORT SYSTEM AT TERRACE - SS Supply and fixing Façade Access Cleaning System with SS-304 grade Cleaning Eye Bolt of suitable size and long at terrace floor. The rate to include for drilling, chemical grouting work, all lead & lift etc. complete as per direction of Engineer-in-charge. All floors
Providing & Conducting Performance Test on Façade work both Structural Glazing and Aluminium Composite Cladding work from the certified laboratories accredited by NABL (National Accreditation Board for Testing and Calibration Laboratories) or by any other accreditation body which operates in accordance with ISO/ IEC 17011 and accredits labs as per ISO/ IEC 17025. 1. Performance Laboratory Test for Air Leakage Test (-50pa to -300pa) & (+50pa to +300pa) as per ASTM E-283-04 testing method for a range of testing limit 1 to 200 mVhr 2. Static Water Penetration Test. (50pa to 1500pa) as per ASTME-331-09 testing method for a range up to 2000 ml. 3. Dynamic Water Penetration (50pa to 1500pa) as per AAMA 501.01- 05 testing method for a range up to 2000 ml 4. Structural Performance Deflection and deformation by static air pressure test (1.5 times design wind pressure without any failure) as per ASTME-330-10 testing method for a range up to 50 mm 5. Seismic Movement Test (up to 30 mm) as per AAMA 501.4-09 testing method for Qualitative test, Tests to be conducted on site. 6. Onsite Test for Water Leakage for a pressure range 50 kpa to 240 kpa (35psi) up to 2000 ml
EXPANSION JOINT
L Profile External Providing and fixing of expansion joint system related with wall joint (internal/external) location as per drawings and direction of Engineer-In- Charge. The joints shall be of extruded aluminium base members, self aligning / centering arrangement and support plates as per ASTM B221- 02. The material shall be such that it provides an Expansion Joints System suitable for vertical wall to wall/ wall to corner application with no slipping down tendency amongst the components of the Joint System. The Joint System shall utilize light weight aluminium profiles exhibiting minimal exposed aluminium surfaces mechanically snap locking the multicellular to facilitate movement. (Material shall confirm to ASTM 6063). Wall Joint of 100 mm gap All floors
Terrace Floor External Providing and fixing of expansion joint system of approved make and manufactures for various roof locations as per approved drawings and direction of Engineer-In-Charge. The joints shall be of extruded aluminium base members with, self aligning and self centering arrangement support plates as per ASTM B221-02. The system shall be such that it provides watertight roof to roof/roof to corner joint cover expansion control system that is capable of accommodating multidirectional seismic movement without stress to its components. System shall consist of metal profile that incorporates a universal aluminium base member designed to accommodate various project conditions and roof treatments. The cover plate shall be designed of width and thickness required to satisfy movement and loading requirements and secured to base members by utilizing manufacturer’s pre-engineered self-centering arrangement that freely rotates / moves in all directions. The Self centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminium extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. The Joint System shall resists damage or deterioration from the impact of falling ice, exposure to UV, airborne contaminants and occasional foot traffic from maintenance personnel. Provision of Moisture Barrier Membrane in the Joint System to have water tight joint is mandatory requirement. (Material shall confirm to ASTM 6063). The Self - centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminium extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. Provision of Moisture Barrier Membrane in the Joint System to have watertight joint is mandatory requirement all as per the manufactures design and as approved by Engineer-in-Charge. (Material shall confirm to ASTM 6063). Ground floor
Floor to Floor Internal Providing and fixing of expansion joint system related with floor location as per drawings and direction of Engineer-In-Charge. The joints system will be of extruded aluminium base members, self aligning / self centering arrangement and support plates etc. as per ASTM B221-02. The system shall be such that it provides floor to floor /floor to wall expansion control system for various vertical location in load application areas that accommodates multi directional seismic movement without stress to it's components. System shall consist of metal profiles with a universal aluminium base member designed to accommodate various project conditions and finish floor treatments. The cover plate shall be designed of width and thickness required to satisfy projects movement and loading requirements and secured to base members by utilizing manufacturer’s pre-engineered self- centering arrangement that freely rotates / moves in all directions. The Self - centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminium extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. Provision of Moisture Barrier Membrane in the Joint System to have watertight joint is mandatory requirement all as per the manufactures design and as approved by Engineer-in-Charge. (Material shall confirm to ASTM 6063). All floors
Floor to Wall Internal same as floor to floor item no.19.03 All floors
Column to Column & Wall to Wall Internal same as floor to floor item no. 19.01 All floors
L Profile C/W Internal same as floor to floor item.no 19.01 All floors
B/B - W/W Internal Providing and fixing in position expansion joint system under roof beam/lintel beam location with aluminium cover plate self aligning / centering arrangement and support plates as per ASTM B221- 02 of suitable thick as per design for expansion joints. All floors
Foam Board between joints Providing and fixing of pre-moulded high performance Expansion Joint Filler Board for 100mm expansion joint of ShaliTex make or best approved quality, complete as per direction of Engineer-in-charge at site. All floors
INTERNAL PARTITION AND FALSE CEILING WORKS General Notes: Rate including all materials, labour charges, wastages, necessary lead and lifts, transportation charges, loading, unloading, scaffolding, staging, installation charges, fuel, consumables as complete with all respects complying with standard specification and as directed by the Engineer-in-charge.
PARTITION FULL HT WITH LAMINATION Providing and fixing of 75mm thick double skin Full Height Partitions with 50mm x 50mm aluminium frame work at 600mm c/c for both horizontals and verticals fixed with 8mm thick BWP plywood (Urea Formaldehyde Free and FSI Certified) fixed in position, the vertical frames fixed to soffit of slab/beam, with necessary screws, MS clamps, rawl plugs, expansion fasteners etc., complete. Lining with 8 mm BWP ply on both sides of frame work from floor level to false ceiling level and finished with 1 mm laminate of approved colour and shade on both sides including necessary grooves, beadings. All concealed faces of BWP ply finished with one coat of wood preservative paint and exposed faces of beading paint finished as directed by Engineer-in-Charge. Measurement for the partition area shall be considered from floor level to false ceiling level only. Note: In Door area concealed 50 x 50mm aluminium frame to be provided. All floors
97mm partition with both side MR gyp board & paint finish Providing and fixing 97.0mm thick Gypwall Hydro partition consist of GypSerra (“Patented in India (325062)”) Metal framework having maximum reachable height of 4000mm satisfying L/240 criterion at 200Pa, possessing fire rating of 30mins, tested in accordance to BS-476 Part 20 & 22 & sound insulation (Rw) of 43dB, tested in accordance to ISO 10140-2/ASTM E90 & spectrum adaption term as per ISO 717-1, having U-value of 0.415W/m²K & Medium duty rating as per BS 5234 part 2. Partition comprises of single layer, tapered edge Gypsum Board, certified GreenPro by CII & strategic location of manufacturing plants results in lower carbon emissions. Partition includes single layer of 12.5mm thick Gyproc Moisture Resistant conforming to IS 2095 Part 1:2011 / EN 520:2004, Type-A & H1, ASTM C1396, MR having flexural strength – {Longitudinal > 500N & transverse > 180N} on both side of framing. GypSerra Metal frame work, in compliance with BS EN 14195 & manufactured using CR1 Grade Steel as per IS 513, having yield stress of 300MPa & tensile strength of 340MPa with surface finish of AZ150 as per IS 15961/AS 1397 & tested for 500hrs of salt spray test as per ASTM B117, includes 70x34x36x0.5mm GypSerra C-Stud with lip of 6.5mm and H-cut-out on web enabling the services to pass, having moment of inertia 61909mm4 about major axis, positioned at 407mm c/c in 72x32x32x0.5mm GypSerra Floor Channel & 72x32x32x0.5mm GypSerra Ceiling Channel with flanges bend at 5° acute angle. Floor & Ceiling Channel is anchored with Gyproc Rawl plug Ø8x45mm having Pull Out strength of 6.8KN or Nail, fixed at 600mm c/c in zig zag manner. 70x40x40x0.5mm GypSerra Noggin Channel to be fitted at the horizontal joints of board. Gyproc Boards to be Screw fixed with Gyproc Drywall Screw of 25mm with 36nos per m2 at 300mm at centre and 150mm at periphery. Edges & joints to be finished with Gyproc Pro-Fill JC conforming to ASTM C475 & Gyproc Paper tape. Periphery & cut-outs of the partition to be treated with suitable Acoustic Sealant having VOC content less than (<) 50 g/litre. All the performance test are carried out at NABL accredited/government approved lab. Rate including providing and applying two or more coats of Plastic emulsion paint having VOC content less than or equal to (≤) 50 grams / litre of approved make and colour on both faces of gypsum board over one coat of primer and two coats of putty required to achieve smooth finish including necessary scaffolding, preparation of surface cleaning of paint stains etc. complete at all levels and as directed by Engineer-in-charge. Note : The Gypsum partition contain 8 to 10% Recycled content. All floors
98mm partition + 1 side MR gyp board with paint finish+ Glasroc-H other side gyp board with laminate finish Providing and fixing gypsum dry wall partition of 97 mm thick Gypwall Hydro+ partition consist of GypSerra (“Patented in India (325062)”) Metal framework having maximum reachable height of 4000mm satisfying L/240 criterion at 200Pa, possessing fire rating of 30mins, tested in accordance to BS-476 Part 20 & 22 & sound insulation (Rw) of 36dB, tested in accordance to ISO 10140-2/ASTM E90 & spectrum adaption term as per ISO 717-1, having U-value of 0.325W/m²K & Medium duty rating as per BS 5234 part 2. Partition comprises of single layer, tapered edge Gypsum Board, certified GreenPro by CII & strategic location of manufacturing plants results in lower carbon emissions. Partition includes single layer of 12.5mm thick Gyproc Moisture Resistant conforming to IS 2095 Part 1:2011 / EN 520:2004, Type-A & H1, ASTM C1396, MR having flexural strength – {Longitudinal > 500N & transverse > 180N} on one side & 12.5mm thick mold resistant Gyproc Glasroc-H with Glass mat reinforcement & inorganic coating on surface, conforming to EN 15283-1 Type GM - FH1,GH having flexural strength – {Longitudinal > 540N & transverse > 210N} on other side of framing. GypSerra Metal frame work, in compliance with BS EN 14195 & manufactured using CR1 Grade Steel as per IS 513, having yield stress of 300MPa & tensile strength of 340MPa with surface finish of AZ150 as per IS 15961/AS 1397 & tested for 500hrs of salt spray test as per ASTM B117, includes 70x34x36x0.5mm GypSerra C-Stud with lip of 6.5mm and H-cut-out on web enabling the services to pass, having moment of inertia 61909mm4 about major axis, positioned at 407mm c/c in 72x32x32x0.5mm GypSerra Floor Channel & 72x32x32x0.5mm GypSerra Ceiling Channel with flanges bend at 5° acute angle. Floor & Ceiling Channel is anchored with Gyproc Rawl plug Ø8x45mm having Pull Out strength of 6.8KN or Nail, fixed at 600mm c/c in zig zag manner. 70x40x40x0.5mm GypSerra Noggin Channel to be fitted at the horizontal joints of board. Gyproc Boards to be Screw fixed with Gyproc Drywall Screw of 25mm with 36nos per m2 at 300mm at centre and 150mm at periphery. Edges & joints to be finished with Gyproc Easi-Fill Hydro JC conforming to ASTM C475 & water absorption <5% as per EN 520 & Gyproc Joint Fibre tape on wet side and Gyproc Pro-Fill JC conforming to ASTM C475 & Gyproc Paper tape on dry side. Periphery & cut-outs of the partition to be treated with suitable Acoustic Sealant having VOC content less than (<) 50 g/litre. All the performance test are carried out at NABL accredited/ government approved lab. Rate including providing and applying two or more coats of Plastic emulsion paint having VOC (Volatile Organic Compound) content less than or equal to (≤) 50 grams / litre of approved make and colour on one face of gypsum board over one coat of primer and two coats of putty required to achieve smooth finish including necessary scaffolding, preparation of surface cleaning of paint stains and one side finished with 1 mm laminate of approved colour and shade including necessary grooves, beadings etc., complete at all levels and as directed by Engineer-in-charge. Note : The Gypsum partition contain 8 to 10% Recycled content. All floors
122mm partition + both side Fire rated gyp board with paint finish. Providing and fixing fire rated gypsum dry wall partition of 122.0mm thick Gypwall Fire Resist partition consist of GypSerra (“Patented in India (325062)”) Metal framework partition having maximum reachable height of 4600mm satisfying L/240 criterion at 200Pa, possessing fire rating of 120mins, tested in accordance to BS-476 Part 20 & 22 & sound insulation (Rw) of 47dB, tested in accordance to ISO 10140-2/ASTM E90 & spectrum adaption term as per ISO 717-1, having U-value of 0.31W/m²K & Severe duty rating as per BS 5234 part 2. Partition comprises of double layer, tapered edge Gypsum Board, certified GreenPro by CII & strategic location of manufacturing plants results in lower carbon emissions. Partition includes double layer of 12.5mm thick Gyproc Fire line conforming to IS 2095 PART1 :2011 / EN520:2004 - TYPE-F, ASTM C1396-TYPE X, having flexural strength – {Longitudinal > 550N & transverse > 210N} on either side of the framing. GypSerra Metal frame work, designed in compliance with BS EN 14195 & manufactured using CR1 Grade Steel as per IS 513, having yield stress of 300MPa & tensile strength of 340MPa with surface finish of AZ150 as per IS 15961/AS 1397 & tested for 500hrs of salt spray test as per ASTM B117, includes 70x34x36x0.5mm GypSerra C-Stud with lip of 6.5mm and H-cut-out on web enabling the services to pass, having moment of inertia 61909mm4 about major axis, positioned at 610mm c/c in 72x32x32x0.5mm GypSerra Floor Channel & 72x32x32x0.5mm GypSerra Ceiling Channel with flanges bend at 5° acute angle. Floor & Ceiling Channel is anchored with Gyproc Rawl plug Ø8x45mm having Pull Out strength of 6.8KN or Nail, fixed at 600mm c/c in zig zag manner. 70x40x40x0.5mm GypSerra Noggin Channel to be placed between the studs, behind the horizontal board joint. Gyproc Fire line Board strip is placed between Ceiling Channel and soffit when fire rating is more than 30mins. Inner & Outer layer of Gyproc Boards to be Screw fixed with Gyproc Drywall Screw of 25mm with 12nos per m2 & 35mm with 24nos per m2 at spacing of 600mm & 300mm respectively. Edges & joints to be finished with Gyproc Pro-Fill JC conforming to ASTM C475 & Gyproc Paper tape. Periphery & cut-outs of the partition to be treated with suitable Fire & Acoustic Sealant having VOC content less than (<) 50 g/litre. All the performance test are carried out at NABL accredited/ government approved lab. Note : The Gypsum partition contain 8 to 10% Recycled content. All floors
PLY PANELLING WITH LAMINATE Providing and fixing of Plywood Wall panelling for internal walls at desired locations as per instructions and to be made with 12mm thick BWP plywood (Urea Formaldehyde Free and FSI Certified). The ply surface shall be finished with 1mm laminate with necessary groove of approved shade and colour including necessary wooden beading with painted finish as per architectural drawing and undulations shall be packed. All floors
PARTITION WITH PARTLY PLY/PARTLY GLASS LOW HT. 2.1 M Providing and fixing of 75mm thick double skin Low Height Partitions of 2100mm height, partly panelled and partly glazed using 8/10 mm thick clear float glass Saint Gobain make as shown in architectural drawing. The Partition shall be made out of 50mm x 50mm aluminium frame work at 600mm c/c for both horizontals and verticals fixed with 8mm thick plywood (Urea Formaldehyde Free and FSI Certified) fixed in position, the vertical frames fixed to floor slab with necessary screws, MS clamps, rawl plugs, expansion fasteners etc., Lining with 8 mm BWP ply on both sides of frame work from floor level to 2100mm height and finished with 1 mm laminate of approved colour and shade on both sides including necessary grooves, beadings. Top of the partition finished with 15 mm thick and 85mm wide wooden moulding and polished with melamine. All concealed faces of BWP ply finished with one coat of wood preservative paint and exposed faces of beading melamine polished as directed by Engineer-in-Charge. All floors
PARTITION WITH FULLY PLY LOW HT. 2.1 M Providing and fixing of 75mm thick double skin Low Height Partitions of 2100mm height with 50mm x 50mm aluminium frame work at 600mm c/c for both horizontals and verticals fixed with 8mm thick plywood fixed in position, the vertical frames fixed to floor slab with necessary screws, MS clamps, rawl plugs, expansion fasteners etc., complete. Lining with 8 mm ply (Urea Formaldehyde Free and FSI Certified) on both sides of frame work from floor level to 2100mm height and finished with 1 mm laminate of approved colour and shade on both sides including necessary grooves, beadings. Top of the partition finished with 15 mm thick and 85mm wide wooden moulding and polished with melamine. All concealed faces of BWP ply finished with one coat of wood preservative paint and exposed faces of beading melamine polished as directed by Engineer-in-Charge. All floors
Trophy Shelf Providing and fixing of Trophy unit of size 1975 X 650 X 2600 mm made up of aluminium frame with openable Tick tock glass shutter including 10mm thick toughened glass shelves fixing with necessary tensile SS string supports. The cabinet made up of ply dummy with 1 mm laminate of approved colour, shade & make and lighting provision inside the cabinet including hardware's with lock provision of approved make as per the drawing. All floors
Notice Board Providing and fixing of Notice Board unit of size 2700 X 650 X 2600 mm made up of aluminium frame with openable Tick tock glass shutter including hardware's with lock provision of approved make as per the drawing. The cabinet made up of ply dummy with soft board of 12 mm thick to be fixed inside the ply dummy as shown in the drawing, fabric cost not less than Rs. 160/m and rest of the ply dummy finished with 1 mm laminate of approved colour, shade & make. Also lighting provisions shall be made inside the cabinet as per the drawing. All floors
Modular Glass Partition System with all-round Aluminium Profile : Providing & fixing of Modular Single glazed partition system (With 10% to 20% Recycled content) as per architectural drawing with Geze make (Geze Dela System GD-45S), consist of aluminium section of 30x45x2 mm thick. All sections duly anodised up to 20–25 microns with 6063-T6 grade and required accessories i.e. glass to glass aluminium I/H sections, T section & 90 degree L sections & Glass packing to adjust the floor level. Ceiling profile, floor profile and wall profile are 30 mm visible face and 45 mm wide with 10mm toughened glass & insertion of Thermoplastic gasket to adhere the glass firm & airtight. The sound reduction value shall be from 32 to 35 Db. Rate including all materials, labour charges, wastages, necessary lead and lifts, transportation charges, loading, unloading, scaffolding, staging, installation charges, fuel, consumables as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge. Note: The Aluminium products shall be 5 % recycled content. All floors
Glass Door for Modular Partition Providing and fixing of 12 mm thick Toughened Glass Door within the Modular glass partition system of Geze make with Floor spring TS500NV using PL50 bottom lock, PT10 bottom patch, PT20 & PT24 Top patch including making necessary holes on glass for fixing handle (Handle will be paid separately). Note: 1. The Aluminium products shall be 5% recycled material content. 2. Toughened Glass partition shall be 10 to 20% Recycled material content. All floors
H type pull handle - 350mm Supply and fixing "H type" stainless steel (SS-304 grade) pull handle of Geze make of size 25 x 350 mm c/c by fixing back to back with necessary SS screws and accessories. All floors
H type pull handle - 450mm Supply and fixing "H type" stainless steel (SS-304 grade) pull handle of Geze make of size 25 x 450 mm c/c by fixing back to back with necessary SS screws and accessories. All floors
H type pull handle - 900mm Supply and fixing "H type" stainless steel (SS-304 grade) pull handle of Geze make of size 32 x 900 mm c/c by fixing back to back with necessary SS screws and accessories. All floors
Internal Partition Joinery
Wooden Doors Providing and fixing Flush door in position Sal wood frame of size 100mmx62mm to partition with 2 coats of synthetic enamel paint (VOC ≤ 50gms / litre) over a coat of primer (VOC ≤ 50gms/litre) of approved make to detail as shown in drawing. Solid flush ply shutter of 35mm (finished) thick Single/Double leaf finished with 1mm thick laminate of approved make, colour & shade on both sides with teak wood lipping all-round the shutter with glass vision panel of specified size provided as per design & drawings with clear glass of suitable thick. The shutter fixed with 4nos of SS double ball bearing butt hinges. Rate inclusive of all material, labour, wastages, scaffolding, scrapping, door hardware of SS Tower bolt for top & bottom, suitable mortise lock with cylinder set, door handle, door closer, door stopper with necessary SS screws of GEZE make or best approved quality., complete at all levels and lead as per drawing and as directed by the Engineer-in-charge. Note: Supply of door Closer, mortise lock set, SS handle will be measured and paid separately under relevant item of works. Note: The Wooden Door shall be Urea Formaldehyde Free and FSI Certified. Same as above, but double leaf and 8mm thick vision panel of size 900 x 150 mm with 19x19mm wooden beading all around and size of the door 1500 x 2400 mm. All floors
Same as above, but frame shall have 25mmx8mm wooden architrave and fixing the same using foam sealant having VOC content less than 50 grams per litre with frame anchor fastener of size 10mmx160mm on wall/column portion of approved make. Shutter shall be of double leaf and the rate shall inclusive of 8mm thick vision panel of size 900 x 150mm, 19x19mm wooden beading etc. Door Size -1200 X 2400 All floors
Same as above, but frame shall have 25mmx8mm wooden architrave and fixing the same using foam sealant having VOC content less than 50 grams per litre with frame anchor fastener of size 10mmx160mm on wall/column portion of approved make. Shutter shall be of single leaf and the rate shall inclusive of 8mm thick vision panel of size 900 x 150mm, 19x19mm wooden beading etc. Door Size -1050 X 2400 All floors
Same as above, but single leaf the rate shall inclusive of 8mm thick vision panel of size 2050 x 150mm, 19x19mm wooden beading etc. Door Size -1050 X 2400 All floors
Same as above, but single leaf the rate shall inclusive of 8mm thick vision panel of size 900 x 150mm, 19x19mm wooden beading etc. Door Size -975 X 2400 All floors
Same as above, but 180 degree openable single leaf shutter with the rate shall inclusive of 8mm thick vision panel of size 900 x 150mm, 19x19mm wooden beading etc. Door Size -975 X 2400 All floors
Same as above, but single leaf the rate shall inclusive of 8mm thick vision panel of size 900 x 150mm, 19x19mm wooden beading etc. Door Size - 900 X 2400 All floors
Partition for Close the Opening Providing and fixing of 66mm thick double skin partitions using G.I. sections, 8mm thick (high pressure steam cured) fibre cement board of Ramco industries or best approved make conforming to IS 14862:2000, fixed on the frame work using 25mm fully threaded self embedding type fibre cement screws @ 300mm c/c on either side of 48/70 mm studs (0.55 mm thick having one flange of 34 mm and another flange of 36 mm) made of G.I. steel placed at 600 mm in 50/72 floor and ceiling channel (0.55 mm thick having equal flanges of 32 mm G.I steel) with joints staggered to avoid through joints, all complete as per drawing & direction of Engineer-in-charge. The boards may be finished so as to have uniform groove or flush finish. The flush finish should be done with elasto prefab joint sealant having VOC content less than (<) 100 g/litre, internal joint compounding and paper tape as per the standard procedure. Finally the boards shall be painted with 2 coats of plastic emulsion paint of approved shade, colour and make, over a coat of primer. All floors
FALSECEILING:
Gypsum Board False Ceiling Gypsum Board False Ceiling: Providing and fixing in position M/F suspended false ceiling to detail with GI frame work and 12.5mm tapered type gypsum board panels to form grids of 45.7 x 122cm as per manufacturers specification including provision for stepped shaped ceiling for indirect lighting as per drawing comprising. Frame work of intermediate channels (M.F.T) at 122cm centres along one direction M/F ceiling section MF5 at 45.7cm centres along other direction. Perimeter channels (MF 6A) along walls around perimeter side of the ceiling, all to detail as per drawing. The intermediate channels suspended from ceiling, through strap hangers 25 x 0.5mm (MF 8) at 122cm centres connected to soffit cleats P534 (27 x 37 x 25 x 1.6mm) the cleats connected to ceiling through metal expansion rawl plugs 1/2" dia. and 17/16" long with necessary bolts and nuts etc. all connected with additional perimeter channels (MF 6A) for openings for light fixtures, AC ducts, vertical drops, offsets etc. wherever necessary all to detail and as per direction. 12.5mm thick gyp board with tapered edges and paper joint tapes for each joints fixed to underside of suspended grid with 25mm screws to form grids of 45.7cm x 122cm varied along wall ends etc., including Architectural boxing, moulding and painting the underside of gypsum board with 1 coat of primer and 2 coats of putty and touch up putty if required to achieve smooth finish. The surface shall be painted with two coats of Premium emulsion paint (VOC less than 50 gms/litre) of approved make to the satisfaction of Engineer-In-Charge. (The false ceiling area will be measured in flat area only for payment.) Note : The Gypsum board contain 5 to 10% Recycled content. All floors
PVC Grid ceiling (600 x 600mm) Providing and Fixing of 24mm prelude 32H grid system manufactured by M/s. Knauf ceiling solutions or equivalent using hot dipped galvanized steel section, exposed surface chemically cleaned capping prefinished in backed polyester paint Wall angle of size 19x19x3000 mm used in periphery of the ceiling fixed to the wall/partition/RCC column/band walls with the help of screws at 600mm c/c. Main runner of size 3000x24 mm x 32H suspended at 1200 mm c/c by using Knauf ceiling solutions (Armstrong) Suspension Systems hanger Wire securely fixed to the structural soffit of RCC slab by using 6mm fastener with Hook Clip for level adjustment at every 1200mm(max) and 1200mm long cross tee of size 24mmx27H to be interlocked between in main runner at 600mm c/c (max) to form grid of 1200x600 mm 600mm long cross tee size 24mmx25H fixed in between 1200mm long cross tee for forming a grid of 600x600mm and finally laying PVC Laminated board edge tile 600x600x6.5 mm All floors
Access Door in Gypsum False ceiling Providing & fixing Trap /access Door for services as per design and detail. Trap Doors to be fabricated in 19mm thk BWR ply with necessary hardwood frames supported from slab. Shutters to be fixed with stainless steel hinges & lock. Edges finished with wooden lipping. Compete trap door unit finished with White Plastic Emulsion Paint etc., all complete as per detail drawing or as specified and as directed by Engineer-in-charge. All floors
Plain Grid Ceiling Armstrong (600 x 600mm) Providing and Fixing of 24mm prelude 32H grid system manufactured by M/s. Knauf ceiling solutions or equivalent using hot dipped galvanized steel section, exposed surface chemically cleaned capping prefinished in backed polyester paint Wall angle of size 19x19x3000mm used in periphery of the ceiling fixed to the wall/partition/RCC column/band walls with the help of screws at 600mm c/c. Main runner of size 3000x24mmx32H suspended at 1200mm c/c by using Knauf ceiling solutions (Armstrong) Suspension Systems hanger Wire securely fixed to the structural soffit of RCC slab by using 6mm fastener with Hook Clip for level adjustment at every 1200mm (max) and 1200mm long cross tee of size 24mmx27H to be interlocked between in main runner at 600mm c/c (max) to form grid of 1200x600mm, 600mm long cross tee size 24mmx25H fixed in between 1200mm long cross tee for forming a grid of 600x600mm and finally laying Knauf ceiling solutions (Armstrong) Beauty sky tegular edge 600x600x14mm (RH90, NRC0.5) Note: 1. The Grid Ceiling should be 5 to 10 % Recycled material content. All floors
Metallic perforated Grid Ceiling (600 x 600mm) Providing and Fixing of 15mm Suprafine 32H grid system manufactured by M/s. Knauf ceiling solutions or equivalent using hot dipped galvanized steel section, exposed surface chemically cleaned capping prefinished in backed polyester paint Wall angle of size 19x19x3000mm used in periphery of the ceiling fixed to the wall/partition/RCC column/band walls with the help of screws at 600mm c/c. Main runner of size 3000x15mmx32H suspended at 1200mm c/c by using Knauf ceiling solutions (Armstrong) Suspension Systems hanger Wire securely fixed to the structural soffit of RCC slab by using 6mm fastener with Hook Clip for level adjustment at every 1200mm (max) and 1200mm long cross tee of size 15mmx32H to be interlocked between in main runner at 600mm c/c (max) to form grid of 1200x600mm 600mm long cross tee size 15mmx32H fixed in between 1200mm long cross tee for forming a grid of 600x600mm and finally laying Knauf ceiling solutions (Armstrong) GI laying plain Micro look edge 600x600x0.5mm. Note: The Grid Ceiling should be 5 to 10 % Recycled material content. All floors
EXTERNAL DEVELOPMENT WORKS
Removing of existing kerb wall and stalking at site
Road Cutting
EXCAVATION Earth work in narrow excavation for foundation in all type of soils and sub soils to the required depth for trenches, plinth / grade beams, catch basins, collection chambers etc.,. by mechanical means including manual excavation in dense soil, disintegrated / weathered / soft rock not requiring blasting as per detailed specification and conforming to safety rules during progress of the work as complete with all respects complying with relevant standard specification. Rate to include levelling, dressing of sides and ramming of bottom with all leads and lifts, transportation, plant and machinery, hire and fuel charges for tools and plants, shoring, strutting required to keep the earth in position and baling out water, dewatering of all ground, surface and rain water, removal of slurry generated while excavation and keeping the area free from water, removal of loose pockets, slips and falls during excavation and compacting the same, Slinging or supporting pipes, electric cables, royalties, Seignorage and taking statutory approvals as necessary to carry out the work as complete with all respects complying with relevant standard specification, as directed by the Engineer-in-charge. Note: Authorised working space shall be considered as per IS 1200. Rate to include for extra earthwork if required over & above the authorised working space for provision of slopes, space for scaffolding, water proofing, shuttering, shoring, strutting etc. Additional excavation if required for execution shall not be paid separately.
For Electrical Trench - 0 to 2m depth.
SWD - 0 to 2m depth.
Transformer - 0 to 2m depth.
Road- 0 to 2m depth.
Supplying and filling with approved Quarry/Crusher dust at the areas wherever required below ground level in layers not exceeding 150mm thick, including levelling, well saturating with water, consolidating and ramming etc., complete. Rate to include loading, unloading and transportation etc., complete and all as per direction of Engineer-in-charge.
Electrical Trench
Transformer Bed
Paver area for road
Footpath
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
Planter Box
PLAIN CEMENT CONCRETE Providing and laying Plain Cement Concrete 1:4:8 (1 portland pozzolona cement : 4 of coarse sand : 8 of hard broken stone jelly) using coarse graded aggregate of 40 mm for levelling course under pile caps, steps, walls, raft, retaining wall, drains, platform etc. including all materials, labour charges, wastages, mixing, curing compaction, transportation, necessary lead and lifts etc. as complete with all respects complying with relevant standard specification, as directed by the Engineer-in-charge.
Electrical Trench
Transformer
Planter Box
Footpath
REINFORCED CEMENT CONCRETE Providing and laying M35 Design Mix for all Reinforced cement concrete using ordinary Portland cement of grade 53 from approved manufacturer, Coarse Sand, 20 mm and down graded size coarse aggregates, necessary approved admixtures as per requirement for the following RCC members of all shapes, including necessary centering, shuttering and excluding reinforcement. Design mix shall be get prior approval from structural consultant before execution. Rate to include all designing the mix, batching plant, mechanical mixing, transporting and placing at all levels, leads, lifts, tools & plants, fuels, all materials, labour charges, wastages, laying, pumping the concrete to all levels, providing sleeves / openings in RCC slabs, compaction by vibrator, curing etc., complete with all respects complying with relevant standard specification and as per direction of Engineer- in- charge. Minimum cement content 380 kg/Cum. Note 1: Part of cement can be substituted with ground granulated blast furnace slag (GGBS) to a maximum of 25%. The physical and chemical properties of GGBS shall conform to IS: 12089-1987 (Reaffirmed 2008). Uniform blending with cement to be ensured in accordance with clauses 5.2 and 5.2.1 of IS:456-2000. Note 2: Quantity of cementitious material considered in this item is @380 kg/cum (285kg OPC + 95kg GGBS). Alternately Portland pozzolona cement with minimum 25% fly ash content can be used instead of Ordinary portland Cement and GGBS. Note 3: Water cement ratio in the concrete mix shall not exceed 0.45.
Raft (Transformer)
Raft (Electrical Trench)
RC Wall (Trench)
Roof Slab (Trench)
RC Wall (SWD)
RC Base Slab (SWD)
RCC Cover Slab
REINFORCEMENT STEEL WORKS Supplying, fabricating and fixing of Fe 500 grade steel in position of steel Reinforcement for all RCC work with Thermo Mechanically Treated Bars (TMT) conforming to IS 1786 of latest version according to drawings and binding the reinforcement with 18 gauge double fold GI binding wire and providing Concrete / PVC cover blocks to maintain the cover as required. Rate to include all bending, tying grills, placing, transportation, lead & lifts, tools & plants, fuels, all materials, labour charges, wastages, laying at all levels, fixing in position, cost of cover blocks, etc. as complete with all respects complying with relevant standard specification, as directed by the Engineer-in-charge.
Transformer
Electrical Trench
MASONRY WORKS
Providing and constructing the masonry block work by using Precast cement concrete solid blocks of size 400 x 200 x 200mm having minimum compressive strength not less than 70kg/cm2 in cement mortar 1:6 (1 portland pozzolona cement : 6 coarse sand) laid to line and levels at all levels etc., including all leads and lifts, wetting the blocks properly by immersing in water before laying in foundation, plinth & superstructure. Rate shall include for staging & scaffolding, raking out joints, curing. complete as per particular specifications, drawings and direction of Engineer-in-Charge. NOTE: The cement concrete blocks shall contain minimum of 40% fly ash by volume of blocks. In Transformer
Providing and Constructing the masonry work by using Precast cement concrete solid blocks of size 400 x 100 x 200mm having minimum compressive strength not less than 70kg/cm2 in cement mortar 1:4 (1 portland pozzolona cement : 4 coarse sand) laid to line and levels at all levels etc., including all leads and lifts, wetting the bricks properly by immersing in water before laying in foundation, plinth & superstructure. Rate shall include for staging & scaffolding, raking out joints, curing. complete as per particular specifications, drawings and direction of Engineer-in-Charge. NOTE: The cement concrete blocks shall contain minimum of 40% fly ash by volume of blocks.
At Ground floor
Supplying and Laying of Kerb wall - Footpath
Supplying and Laying of Kerb wall - Road
PLASTERING AND PAINTING WORKS
Providing 15mm thick cement plaster in single coat with CM 1:5 (1 portland pozzolona cement : 3 fine Sand) for external wall surface in smooth finishing to line and level with cement rendering, rounding of all corners wherever required, including GI plaster mesh of Arpitha make for junctions of masonry and RCC works, button marking, levelling, scaffolding, curing, etc., complete as directed by the Engineer-in-charge. The rate is inclusive of forming of plaster or drip band/moulds, architectural grooves etc., as per direction of Engineer-in-charge. Note: All plastering shall be included 150mm wide GI plaster mesh made out of galvanized iron of nominal thickness 0.35mm with a zinc coating of 120 gms/Sqm (ARPITHA/Equivalent) with Galvanised nails etc., for junctions of masonry and RCC works & electrical conduiting area, packing of electrical, plumbing pipes etc., hacking at RCC surface, scaffolding, lifting etc., For Planter box
Painting : Providing and applying two or more coats of Plastic emulsion paint having VOC (Volatile Organic Compound) content less than or equal to (≤) 50 grams / litre of approved make and colour for External Wall over one coat of primer and touch up putty if required to achieve smooth finish including necessary scaffolding, preparation of surface cleaning of paint stains, curing etc., complete at all levels and as directed by Engineer-in-charge. For Planter box
ROAD WORKS
Providing, laying, spreading and compacting graded stone aggregate (size range 53 mm to 0.075 mm) to wet mix macadam (WMM) specification including premixing the material with water at OMC in for all leads & lifts, laying in uniform layers with mechanical paver finisher in sub- base / base course on well prepared surface and compacting with vibratory roller of 8 to 10 tonne capacity to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. Main Road
Providing and laying C.C. pavement of mix M-25 with ready mixed concrete from batching plant. The ready mixed concrete shall be laid and finished with screed board vibrator and finally finished by power trowel, brooming with wire brush including making grooves of 6mm wide & 50mm deep with groove cutting machine and filling with gun grade polysulphide sealant etc. complete as per specifications and directions of Engineer-in-charge. (The panel size shall not exceed 3m x 3m) Note : Rate shall inclusive of Cutting with diamond cutter on existing road surface for alignment and Bonding agent shall be applied on old concrete surface of road. M25 Concrete (For Road)
Construction of dry lean cement concrete sub base over a prepared sub-grade with coarse and fine aggregate conforming to IS:383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per specifications, cement content not to be less than 150 Kg/cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, for all leads & lifts, laid with a mechanical paver, compacting with 8-10 tonne vibratory roller, finishing and curing etc. complete as per direction of Engineer-in- charge. M15 Concrete (For Road)
Supplying and laying precast concrete hydraulically pressed machine made Interlocking paver blocks of made from M35 grade concrete - 60 mm thick approved by architect including transportation of the blocks to the site preparation of surface including supplying and filling with dry coarse sand to 75 mm thick, levelling and compacting with plate vibrator and laying of the inter locking paving blocks with sand binding and final compaction with plate vibrator of 3 ton capacity finishing the surface including cutting of blocks at the edges including all labour and materials etc. complete, as directed by the Engineer-in-charge. 60mm Paver
Supplying and laying precast concrete hydraulically pressed machine made Interlocking paver blocks of made from M35 grade concrete - 80 mm thick approved by architect including transportation of the blocks to the site preparation of surface including supplying and filling with dry coarse sand to 75 mm thick, levelling and compacting with plate vibrator and laying of the inter locking paving blocks with sand binding and final compaction with plate vibrator of 3 ton capacity finishing the surface including cutting of blocks at the edges including all labour and materials etc. complete, as directed by the Engineer-in-charge. 80mm Paver
Providing and fixing in position pre-moulded joint filler in expansion joints of 25 mm thick and 125mm depth. The expansion joints shall be filled with bitumen hot sealing compound of 25 width and 25 mm depth using grade 'A' sealing compound as per drawing and direction of Engineer-in-charge. Road work
GREEN BUILDING & LANSCAPING LIST OF PROVISION AS PER GREEN BUILDING REGULATIONS DURING CONSTRUCTION
Site Barricading - Supply and installation of galvanized steel sheet or equivalent of 0.4mm thickness with MS steel frame work & supports with MS pipe/channel up to 6m height including necessary concrete foundation etc., complete as directed by the Engineer-in-charge. Note: 1.It shall be one time installation and shall be keep and manage properly until completion of work. After completion & handing over the same shall be removed from the site premises. 2.It shall be without any gaps in between the barricading panels/sheets and shall be got prior approval. Ground Floor
Providing and Maintaining Dustbins to collect the waste to be generated by the workers(capacity suitable to site requirement) during construction Stage. Segregate recyclable wet (organic & food wastes), dry (paper, plastic, metal, cardboard, glasses etc.) & hazardous wastes (batteries, mercury containing lamps, e-waste) by providing separate bins in construction site. Collect all the waste in proper manner and depose off the same in regular interval as per LEED green building requirements.
Conducting test in NABL accredited laboratory for Drinking water utilized by the labourers and other workers accreditation to ensure the parameters of pH, alkalinity etc. as specified by the BIS standards
Testing of top-soil to ensure that it is fit for preservation and reuse. Parameters to be tested: pH, Conductivity, Nitrogen, Phosphorus, Potassium, Calcium, Magnesium, Sodium, Chloride, Total Organic Carbon, Boron, Sulphate, Alkalinity, Copper, Zinc. To be tested in ICAR accredited Lab for pH, Nutrients and Organic Matter.
Conducting test with the help of NABL accredited laboratory for Indoor Air Quality of building as per LEED requirements. Refer Air Quality methodology and parameters as per LEED Green Building requirement given in green building technical specification.
Providing and implementation of Landscape work with necessary native species to suit the climate conditions of the present site including suitable red soil with manure for landscape, necessary irrigation system with control panel, etc. as per direction of Engineer-in-charge. Rate shall inclusive of preparing shop drawings (based on LEED Green Building system requirement) and the same shall be get prior approval from the architect and Green Building Consultant before proceeding the work at site,. Also the landscape work should full fill below requirements: 1. less than 20% Lawn area. 2. More than 40% Shrubs. 3. List of Native Species as per technical specification. 4.Transplantation of required number(approximately 5-10 nos) of trees, which will be obstacle to the construction of new buildings and roads (check site condition and survey drawings) to new available locations (Either within Site or any other sites) as per site conditions.
Supplying and fixing EV Charging Station for two wheelers: 1. 32 Amps EV Charging - 2 wheelers
Supplying and fixing EV Charging Station for Car: 1. 32 Amps EV Charging station for 4 cars.
LIST OF PROVISION AS PER GREEN BUILDING REGULATIONS POST CONSTRUCTION
Supplying and laying of Entry way mat 3 m wide for entry door way of building for a door opening length suitable to US Green Building Council requirement. (LEED)
Providing and fixing bicycle parking stand (35 no's for regular occupants, 4 no's for visitors shall be allocated separately) complete all as per direction of Engineer-in-charge/Green building consultant.
Providing Epoxy Markings for Car pooling, preferred car parking area, Physically disabled car parking, etc. thickness and laying procedure shall be followed as per approved manufacturer specification and direction of Engineer-in-charge.
Providing Tri-coloured bins for Recyclable, Hazardous and Organic Wastes to be generated on-site at designated places as per green building requirement. Additionally, signage's of suitable size(shall be visible) and material complying green building requirements for e-waste, batteries, lamps bin and common waste storage area should be kept as per direction of Engineer-in-charge/green building consultant.
Providing and fixing Terracotta organic waste converters of Dimensions = 42 inches dia x 38" height - Daily Dump Aaga 550 or best approved quality - of 18 kg processing capacity per day. Inclusive of required accessories such as coco-peat (30 kg), compost microbes (1 kg), plastic drum with lid, rake, gloves, tarpaulin cover, transportation, installation and service support, etc. Install as on-site waste treatment system for handling 100% of the organic (kitchen) waste generated in the building (including tenant occupied areas).
Conducting test with the help of NABL accredited laboratory for Air Quality of building as per LEED requirements just after construction. Refer Air Quality methodology and parameters as per LEED Green Building requirement given in green building technical specification.
PROVIDING OF SAFETY AND OTHER SIGNAGES, POSTERS WITH SUITABLE MATERIALS AT NECESSARY LOCATIONS INCLUDING PROTECTING THE SAME DURING WHOLE CONSTRUCTION PERIOD UNTILL HANDING OVER OF THE SITE . Note: 1. All these construction stage signage's must be placed in the local language as well as English. 2. General safety and alert signage's required by the project construction team to be posted in additional to all of these.
Providing Signage for all Labourers Safety Gear to wear as appropriate Providing Signage of Open ducts/pipes to be covered to ban dust, birds & other small insects entering into it. Providing Signage for areas prohibited or sealed to avoid workers/site visitors falling from heights. Providing Signage for 3m barricade all around the site to avoid dust and noise transmission between adjacent spaces. Providing Signage for the storm water trench all around the site and sedimentation pits location during construction. Providing Signage for indicate the labourer huts for rest and toilet facilities for both men & women workers Providing Signage to identify if multiple sheds for site office, conference, test lab, common store etc., based on during construction must be developed. Providing Signage for the dustbins to collect the waste to be generated by the workers. Providing Signage for the drinking water provision within the construction site. Providing Signage for the First-Aid facility during emergency within the working campus. Providing Signages for indicating Proper segregation of construction materials and stored and the waste from which generated during the construction has to be placed with specific signage's in line with material type. Providing Signages for indicating "No Smoking" within the construction work areas and even at the site entrance Providing Signages apart from these above, any digital signage to be kept if recommended by the project team for advertising, information, entertainment and merchandising as per their needs.
GREEN BUILDING RELATED SIGNAGES AND POSTERS TO BE KEPT POST CONSTRUCTION Providing Signage for showing bicycle parking (segregate 35 no's for regular occupants, 4 no's for visitors) Providing Signage for indicating the Shower & changing facilities inside the site Providing Signage for Car pooling should be demarcated in the preferred car parking area. Providing Signage for Physically disabled car parking near the entrance of lift or ramps. Providing Signage for Visual warning in all common areas for Physically handicapped people. Providing Signage for indicating Green Vehicles & electric car charging point in the parking area. Providing Water meters labells with specific to purpose of tracking Potable & various non-potable water use in the building. Providing Energy meters labells to represent various end uses such as HVAC, lighting, Process loads, DG, UPS, Solar PV, etc. according to energy requirements of the building. Providing Signage for Tri-coloured bins for Recyclable, Hazardous and Organic Wastes to be generated on-site. for e-waste, batteries, lamps bin and common waste storage area should be kept. Providing Signage for the OWC (Organic Waste Converter) which helps to convert Kitchen, pantry & landscape waste to be generated on site. Providing No Smoking signage within 10 feet in front of the building & site entrance and 25 feet around the site boundary in spaces used for business purposes. Providing No Smoking signage in the common corridors, Lobbies, courtyard, Staircases, Toilets for the facility. Providing Green education posters for saving the Water, Energy & waste segregation is to be kept wherever possible in common areas. Providing Design Notice board and also Separate boards to display the following items: a) Green Cleaning Policy b) Sustainable Purchasing Policy c) No smoking Policy d) Green Education posters/ Green Training e) General posters for COVID-19 symptoms and awareness
Providing Signage for the Green Cleaning chemicals & equipment's stored. Providing Signage for the physical activities which helps to encourage the occupant wellness. Providing Signage for indicating the location of Rainwater Harvesting Tank; Rainwater filters, Sewage Treatment Plant Providing Signage for the staircases, fire fighting equipment's to be installed. Providing Signage for apart from above, any digital signage to be kept if recommended by the project team for advertising, information, entertainment and merchandising as per their needs. Providing Signage for Recycling should be kept in site. Add approx. 25 Sign boards of A3 size extra
Description of Work / Item(s)
Amount
SANITARYWARE AND CP FITTINGS
EUROPEAN WATER CLOSET CONCEALED CISTERN
Supplying, installing, testing and commissioning the best quality approved make of White glazed Wall mounted European Water closet with double flapped seat cover, pan connector, fisher bolt and including all fittings, making the required size including cutting the wall, redoing the plastering and packing the wall with smooth finish, the side gap between EWC mouth and pan connector to be filled with silicon sealant etc. as complete with all respects complying with relevant standard specification, as directed by the Engineer-in- charge.
Supplying, installing, testing and commissioning the best quality approved make of Dual flush Concealed cistern with floor standing type and Flush Plate (Dual flush rate = 2 /4 (half/full flush) Liters Per Flush comply with leeds) and including all fittings, making the required size including cutting the wall, and fixing the flushing cistern properly, redoing the plastering and packing the wall with smooth finish etc. as complete with all respects complying with relevant standard specification, as directed by the Engineer-in- charge.
Supplying, installing, testing and commissioning the best quality approved make of 2 in 1 Bip cock with wall flange including cutting and making good the walls wherever required etc. as complete with all respects complying with relevant standard specification, as directed by the Engineer-in-charge.
Supplying, installing, testing and commissioning the best quality approved make of C.P. Health Faucet with 1.5m Braided Hose and wall Hook (Less than 5 Litre per Minute comply with leeds), including cutting and making good the walls wherever required etc.as complete with all respects complying with relevant standard specification, as directed by the Engineer-in-charge.
EUROPEAN WATER CLOSET OPEN CISTERN
Supplying, installing, testing and commissioning the best quality approved make of White glazed Wall mounted European Water closet with double flapped seat cover, pan connector, fisher bolt, and including all fittings, making the required size including cutting the wall, redoing the plastering and packing the wall with smooth finish, the side gap between EWC mouth and pan connector to be filled with silicon sealant etc. as complete with all respects complying with relevant standard specification, as directed by the Engineer-in- charge.
Supplying, installing, testing and commissioning the best quality approved make of PVC cistern dual flush and Flush pipe (Dual flush rate = 2 /4 (half/full flush) Liters Per Flush comply with leeds),connecting hose 450mm and including all fittings, making the required size including cutting the wall, and fixing the flushing cistern properly, redoing the plastering and packing the wall with smooth finish etc. as complete with all respects complying with relevant standard specification, as directed by the Engineer-in- charge.(Meant for the above item)
Supplying, installing, testing and commissioning the best quality approved make of Angle Cock with Wall flanges and including all fittings etc. as complete with all respects complying with relevant standard specification, as directed by the Engineer-in- charge.
C.P. HEALTH FAUCET
Supplying, installing, testing and commissioning the best quality approved make of 2 in 1 Bip cock with wall flange including cutting and making good the walls wherever required etc. as complete with all respects complying with relevant standard specification, as directed by the Engineer-in-charge.
Supplying, installing, testing and commissioning the best quality approved make of C.P. Health Faucet with 1.5m Braided Hose and wall Hook (Less than 5 Litre per Minute comply with leeds), including cutting and making good the walls wherever required etc.as complete with all respects complying with relevant standard specification, as directed by the Engineer-in-charge.
INDIAN WATER CLOSET
Supplying, installing, testing and commissioning the best quality approved make of water closet squatting pan Indian type W.C. pan with 100 mm P or S trap. as complete with all respects complying with relevant standard specification, as directed by the Engineer-in- charge.
Supplying, installing, testing and commissioning the best quality approved make of PVC cistern dual flush and Flush pipe (Dual flush rate = 2 /4 (half/full flush) Liters Per Flush comply with leeds),connecting hose 450mm and including all fittings, making the required size including cutting the wall, and fixing the flushing cistern properly, redoing the plastering and packing the wall with smooth finish etc. as complete with all respects complying with relevant standard specification, as directed by the Engineer-in- charge. (Meant for the above item).
Supplying, installing, testing and commissioning the best quality approved make of Bib cock with Wall flanges and including all fittings etc.. as complete with all respects complying with relevant standard specification, as directed by the Engineer-in- charge.
WASH BASIN
Supplying, installing, testing and commissioning the best quality approved make of White glazed earthenware Wash Basin of 550 x 400 mm with all accessories, including fixing the wash basin in the wall in position with fisher bolt and giving necessary water supply connection and painting the brackets with two coats of paint over a priming coat of anticorrosive paint including testing for leakage etc., as complete with all respects complying with relevant standard specification, as directed by the Engineer-in-charge.
Supplying, installing, testing and commissioning the best quality approved make of 15mm dia C.P. Pillar taps (Less than 1.4 litre per minute comply with leeds),15 mm Dia Brass Nipples and 15 mm Dia Nylon connection., as complete with all respects complying with relevant standard specification, as directed by the Engineer-in-charge.
Supplying, installing, testing and commissioning the best quality approved make of 32 mm Dia C.P. Waste coupling.,(Half thread) as complete with all respects complying with relevant standard specification, as directed by the Engineer-in-charge.
Supplying, installing, testing and commissioning the best quality approved make of 32 mm dia Bottle Trap., as complete with all respects complying with relevant standard specification, as directed by the Engineer-in-charge.
Supplying, installing, testing and commissioning the best quality approved make of Angle Cock with Wall flanges and including all fittings etc. as complete with all respects complying with relevant standard specification, as directed by the Engineer-in- charge.
WASH BASIN (COUNTER)
Supplying, installing, testing and commissioning the best quality approved make of White glazed over Counter Wash Basin of 470x470 mm with all accessories, including fixing the wash basin in the wall in position with fisher bolt and giving necessary water supply connection and painting the brackets with two coats of paint over a priming coat of anticorrosive paint including testing for leakage etc., as complete with all respects complying with relevant standard specification, as directed by the Engineer-in-charge.
Supplying, installing, testing and commissioning the best quality approved make of 15mm dia C.P. Pillar taps (Less than 1.4 litre per minute comply with leeds),15 mm Dia Brass Nipples and 15 mm Dia Nylon connection., as complete with all respects complying with relevant standard specification, as directed by the Engineer-in-charge.
Supplying, installing, testing and commissioning the best quality approved make of 32 mm Dia C.P. Waste coupling. (half thread), as complete with all respects complying with relevant standard specification, as directed by the Engineer-in-charge.
Supplying, installing, testing and commissioning the best quality approved make of 32 mm dia Bottle Trap., as complete with all respects complying with relevant standard specification, as directed by the Engineer-in-charge.
Supplying, installing, testing and commissioning the best quality approved make of Angle Cock with Wall flanges and including all fittings etc. as complete with all respects complying with relevant standard specification, as directed by the Engineer-in- charge.
PHYSICALLY CHALLENGED PERSONS TOILET
EUROPEAN WATER CLOSET OPEN CISTERN
Supplying, installing, testing and commissioning the best quality approved make of White glazed Wall mounted European Water closet with double flapped seat cover, pan connector, fisher bolt, and including all fittings, making the required size including cutting the wall, redoing the plastering and packing the wall with smooth finish, the side gap between EWC mouth and pan connector to be filled with silicon sealant etc. as complete with all respects complying with relevant standard specification, as directed by the Engineer-in- charge.
Supplying, installing, testing and commissioning the best quality approved make of PVC cistern dual flush and Flush pipe (Dual flush rate = 2 /4 (half/full flush) Liters Per Flush comply with leeds),connecting hose 450mm and including all fittings, making the required size including cutting the wall, and fixing the flushing cistern properly, redoing the plastering and packing the wall with smooth finish etc. as complete with all respects complying with relevant standard specification, as directed by the Engineer-in- charge. (Meant for the above item).
Supplying, installing, testing and commissioning the best quality approved make of Angle Cock with Wall flanges and including all fittings etc. as complete with all respects complying with relevant standard specification, as directed by the Engineer-in- charge.
C.P. HEALTH FAUCET
Supplying, installing, testing and commissioning the best quality approved make of 2 in 1 Bip cock with wall flange including cutting and making good the walls wherever required etc. as complete with all respects complying with relevant standard specification, as directed by the Engineer-in-charge.
Supplying, installing, testing and commissioning the best quality approved make of C.P. Health Faucet with 1.5m Braided Hose and wall Hook (Less than 5 Litre per Minute comply with leeds), including cutting and making good the walls wherever required etc.as complete with all respects complying with relevant standard specification, as directed by the Engineer-in-charge.
WASH BASIN
Supplying, installing, testing and commissioning the best quality approved make of White glazed earthenware Wash Basin of 550 x 400 mm with all accessories, including fixing the wash basin in the wall in position with fisher bolt and giving necessary water supply connection and painting the brackets with two coats of paint over a priming coat of anticorrosive paint including testing for leakage etc., as complete with all respects complying with relevant standard specification, as directed by the Engineer-in-charge.
Supplying, installing, testing and commissioning the best quality approved make of 15mm dia C.P. Pillar taps (Less than 1.4 litre per minute comply with leeds),15 mm Dia Brass Nipples and 15 mm Dia Nylon connection., as complete with all respects complying with relevant standard specification, as directed by the Engineer-in-charge.
Supplying, installing, testing and commissioning the best quality approved make of 32 mm Dia C.P. Waste coupling.(Half thread), as complete with all respects complying with relevant standard specification, as directed by the Engineer-in-charge.
Supplying, installing, testing and commissioning the best quality approved make of 32 mm dia Bottle Trap., as complete with all respects complying with relevant standard specification, as directed by the Engineer-in-charge.
Supplying, installing, testing and commissioning the best quality approved make of Angle Cock with Wall flanges and including all fittings etc. as complete with all respects complying with relevant standard specification, as directed by the Engineer-in- charge.
Supplying, installing, testing and commissioning the best quality approved make of Grab bar Folding type and including all fittings etc. as complete with all respects complying with relevant standard specification, as directed by the Engineer-in- charge.
Supplying, installing, testing and commissioning the best quality approved make of Grab bar 600mm and including all fittings etc. as complete with all respects complying with relevant standard specification, as directed by the Engineer-in- charge.
MIRROR
Supplying and fixing in position best quality approved of 600x750 mm bevelled edge Mirror of superior glass complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
Supplying and fixing in position best quality approved of 1300x600 mm bevelled edge Mirror of superior glass complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
Supplying and fixing in position best quality approved of 2500x600 mm bevelled edge Mirror of superior glass complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
Supplying and fixing in position best quality approved of 4000x600 mm bevelled edge Mirror of superior glass complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
TOILET PAPER HOLDER Supplying and fixing the best quality approved make of chromium plated toilet paper holder with same material including cost of C.P. Screws etc., as complete with all respects complying with relevant standard specification, as directed by the Engineer-in-charge.
SOAP DISHES Supplying and fixing in position best quality approved of Soap Dish including cost of C.P. Screws etc., as complete as per direction of Engineer in Charge
TOWEL RING Supplying and fixing in position best quality approved of Towel Ring including cost of C.P. Screws etc., as complete as per direction of Engineer in Charge
URINALS Supplying and Fixing in position best quality approved make of White glazed earthen ware lipped mouth Flat Back Urinal (Less than 1 Liters Per Flush or Waterless Urinal) of best approved quality with G.I. Pipe connection to suitable length,32mm bell mouthing P.V.C connection , fixing the urinal to the wall in position with necessary T.W. plugs ,clamps, screws, shellac etc., including dismantling masonry if necessary and redoing the same to original condition ,fixing the 15mm dia. G.I. Pipe connection and gun metal wheel valve ,painting the pipe with two coats of approved colour of synthetic paint over one coat of primer and etc., checked without leakage etc., as complete with all respects complying with relevant standard specification, as directed by the Engineer-in-charge.
LINER GRATING
supplying and fixing in position best quality approved make 200x4000mm SS-304 Liner Grating with removal strainer for as complete with all respects complying with relevant standard specification, as directed by the Engineer-in-charge.
supplying and fixing in position best quality approved make 450x2000mm SS-304 Liner Grating with removal strainer for as complete with all respects complying with relevant standard specification, as directed by the Engineer-in-charge.
KITCHEN SINK
Supplying and fixing in position best quality approved make of Kitchen Sink pressed series glossy Size 24X18X8 , fixing the sink in the platform in position and giving necessary water supply connection and testing for leakage etc., as complete with all respects complying with relevant standard specification, as directed by the Engineer-in-charge.
Supplying and fixing in position best quality approved make of Swan Neck Sink Tap and all accessories such as 15 mm Dia Nylon connection, 15 mm Dia Brass Nipples and including testing for leakage etc., as complete with all respects complying with relevant standard specification, as directed by the Engineer-in-charge.
Supplying, installing, testing and commissioning the best quality approved make of 32 mm Dia C.P. Waste coupling., (Full thread) as complete with all respects complying with relevant standard specification, as directed by the Engineer-in-charge.
Supplying, installing, testing and commissioning the best quality approved make of 32 mm dia Bottle Trap., as complete with all respects complying with relevant standard specification, as directed by the Engineer-in-charge.
Supplying, installing, testing and commissioning the best quality approved make of Angle Cock with Wall flanges and including all fittings etc. as complete with all respects complying with relevant standard specification, as directed by the Engineer-in- charge. (The rate should include the flexible connection)
WATER DISPENSER Supply & fixing of Water Dispenser of approved make
WATER SUPPLY PIPES
CONCEALED PIPE LINE & WITHIN THE TOILET: Supplying, laying, jointing and testing of the following sizes of CPVC pipes (SDR 11) of approved quality and best variety conforming to I.S. and with I.S.I mark, including cutting, threading and fixing to CPVC specials, laid properly to alignment but excluding the cost of such specials and fixing to wall with necessary Clamps and screws, making holes on the wall or drilling holes in the roof and making good the dismantled portions to original condition with necessary brick work and concrete plastering wherever necessary with necessary scaffolding charges etc. as complete with all respects complying with relevant standard specification, as directed by the Engineer-in-charge.
20 mm nominal dia
25 mm nominal dia
32 mm nominal dia
40 mm nominal dia
VERTICAL AND TERRACE PIPES: Supplying, laying, jointing and testing of the following sizes of CPVC pipes (SDR 11) of approved quality and best variety conforming to I.S. and with I.S.I mark, including cutting, threading and fixing to CPVC specials, laid properly to alignment but excluding the cost of such specials and fixing to wall with necessary Clamps and screws, making holes on the wall or drilling holes in the roof and making good the dismantled portions to original condition with necessary brick work and concrete plastering wherever necessary with necessary scaffolding charges etc. as complete with all respects complying with relevant standard specification, as directed by the Engineer-in-charge.
25 mm nominal dia
32 mm nominal dia
40 mm nominal dia
50 mm nominal dia
65 mm nominal dia
Supplying and fixing in position of concealed & exposed ISOLATING VALVE for the following dia, approved quality and making holes on the wall and making good the dismantled portions to original condition with necessary plastering charges etc. as complete with all respects complying with relevant standard specification, as directed by the Engineer-in-charge.
Supplying and fixing of Ball valve (PN16) for the following dia. as complete with all respects complying with relevant standard specification, as directed by the Engineer-in-charge.
Supplying and fixing of Non-Return Valve (CP Brass PN16) for the following dia. as complete with all respects complying with relevant standard specification, as directed by the Engineer-in-charge. 40 dia
INTERNAL DRAINAGE P.V.C. Soil / Waste Pipes (6 Kg/ Sqcm) IS 13592 SWR grade Supplying and laying in position best quality P.V.C soil/waste pipes and P.V.C. specials such as plain bend, door bend, plain tee, door tee, offsets, Y-junction, plain or with door of various sizes best quality confirming to various sizes having ISI mark and providing leak-proof joints including fixing to the wall with P.V.C/M.S clamps etc., and making connection to all sanitary fittings and soil, waste line, dismantling masonry/R.C.C. works wherever necessary and making good the dismantled portion to the original condition, as complete with all respects complying with relevant standard specification, as directed by the Engineer-in-charge. Application: Drainage internal, vertical stack and rain water pipes.
50mm dia
75mm dia
110mm dia
EXTERNAL & VERTICAL DRAINAGE P.V.C. Soil / Waste Pipes (6 Kg/ Sqcm) IS 13592 SWR grade Supplying and laying in position best quality P.V.C soil/waste pipes and P.V.C. specials such as plain bend, door bend, plain tee, door tee, offsets, Y-junction, plain or with door of various sizes best quality confirming to various sizes having ISI mark and providing leak-proof joints including fixing to the wall with P.V.C/M.S clamps etc., and making connection to all sanitary fittings and soil ,waste line , dismantling masonry/R.C.C. works wherever necessary and making good the dismantled portion to the original condition, as complete with all respects complying with relevant standard specification, as directed by the Engineer-in-charge. Application: Drainage internal, vertical stack and rain water pipes.
75mm dia
110mm dia
160mm dia
FLOOR TRAP: Supplying, fixing and testing of PVC floor trap (Multi trap) fixed in sunken floors, including dismantling masonry works wherever found necessary and making good the damaged portions to the original and giving connections to the pipe as directed etc., as complete with all respects complying with relevant standard specification, as directed by the Engineer-in-charge.
ANTI COCKROACH GRATINGS FOR ALL FLOOR TRAPS: Supplying, fixing and testing of SS anti cockroach gratings of size 150 x 150 over PVC floor trap (Multi trap) fixed in sunken floors, including dismantling masonry works wherever found necessary and making good the damaged portions to the original and giving connections to the pipe as directed etc., as complete with all respects complying with relevant standard specification, as directed by the Engineer-in-charge.
TRANSFER PUMP: Supplying and fixing in position best quality approved make of 3 star rated Transfer pump By With necessary & Control Panel, Float switch as complete with all respects complying with relevant standard specification, as directed by the Engineer-in-charge. Discharge : 12m³/hr @ Head 60mrt
INSPECTION CHAMBER: Providing and constructing manhole chambers of 1.4 meter dia for connecting sewer lines of following depths in first class B.B. masonry works in C.M1:6 (one cement and six sand) including laying cement concrete bedding 150 mm thick of grade 1:3:6 for foundation and bedding and projecting 100 mm outside the brick wall, providing 20mm thick cement plaster (1:3) from inside with cement punning (Ghotai) 1:3 cement mortar for outside & providing C.I manhole (HD) cover along with frame,. complete with all respects complying with relevant standard specification, as directed by the Engineer-in-charge. Manhole 600 x 600
GULLY TRAP: Supplying and fixing in position 150 X 100mm square mouth 'P' or 'S' trap stoneware Gully Trap A grade with cast-iron gratings of size 150 X 150mm with C.I. air tight cover with frames of size 300 X 300mm (HD) at bottom and top respectively laid over a bed of brick jelly cement concrete 1:3:6 150mm thick using 40mm size broken brick jelly including necessary solid block work and plastering and including dismantling masonry wherever necessary and redoing the damaged portions to the original condition and by using cement concrete 1:3:6 using 20mm stone jelly for fixing the gully trap and giving connections to the stoneware sewer line etc., as complete with all respects complying with relevant standard specification, as directed by the Engineer-in-charge.
GREASE TRAP: Supplying and fixing in position grease interceptors at flow rate of 3.2lps with 4” outlet. To be kept that enclosed brick work chamber with necessary vent arrangement. as complete with all respects complying with relevant standard specification, as directed by the Engineer-in-charge.
RAIN WATER HARVESTING PIT: Providing and Construction of Rain water Harvesting Pit (900 mm dia) as per consultant drawing with all necessary connections, including manhole cover, as complete with all respects complying with relevant standard specification, as directed by the Engineer-in-charge.
RAIN WATER OUTLET: Providing and Construction of Rain water outlet 300x300mm grating as complete with all respects complying with relevant standard specification, as directed by the Engineer-in-charge.
WATER METER: Supply & fixing of Water Meter of approved make
Description of Work / Item(s)
Amount
SEWAGE TREATMENT PLANT 35 KLD CAPACITY
STP EQUIPEMTS
Bar Screen : Supply and fixing of bar screen with MOC -Ms epoxy as per standard speciation etc. complete complying as per standard specification the make and quality should be approved by engineer-in-charge before installation
Raw Sewage Transfer Pump : Supply ,installation testing and commissioning of 1 HP raw sewage pump centrifugal non clog pump per standard specification etc. complete complying as per standard specification(the make and quality should be approved by engineer-in-charge before installation) Approved Make; Kirloskar/CRI/ Crompton and Greaves/ISI Approved Equivalent.
Dosing Tank : Supply, installation testing and commissioning of Dosing tank of 50 liters capacity in LLDPE / FRP / PP material and dosing pump of 0 - 6 lph range with 2.0 bar working pressure electronic metering type pump specification (the make and quality should be approved by engineer-in-charge before installation) Approved Make; UKL, FTPS/E DOSE/ISI Approved Equivalent.
Blower System: Supply ,installation testing and commissioning of nos -1 working + 1 standby blower system. MotorA1/EVEREST/Airvac/ISI Approved equivalent.
Blower Motor: Supply, installation testing and commissioning of 3Hp blower Motor per standard specification etc. complete complying as per standard specification (the make and quality should be approved by engineer-in-charge before installation) Approved Make-Kirloskar/CRI/Crompton Greaves/ISI Approved equivalent.
Diffuser System: Supply ,installation testing and commissioning of Diffuser system, MOC-EPDM over the collection tank standard specification etc.complete complying as per standard specification(the make and quality should be approved by engineer-in-charge before installation) Approved Make- Suzuki/ Tecpro/equivalent.
Tube Settler : Supply, installation testing and commissioning of Tube settler 750mm dia secondary clarifier mechanism, central driven as per specifications provided in the Design Section
Return Sludge :Supply,installation testing and commissioning of Return sludge Two (2) nos - 1 working + 1standby, 10 mwc horizontal centrifugal, non clog, semi open CI impeller pump with 1 hp rating, suitable for handing underflow. complete complying as per standard specification (the make and quality should be approved by engineer-in-charge before installation) Approved Make; Kirloskar/CRI/ Crompton and Greaves/ISI Approved Equivalent.
Filter Feed Pump : Supply, installation testing and commissioning of 1.5 Hp Filter Feed Pump -Monoblock type centrifugal Pump per standard specification etc. complete complying as per standard specification (the make and quality should be approved by engineer-in-charge before installation) Approved Make;Kirloskar/CRI/ Crompton and Greaves/ISI Approved Equivalent.
PSF of MOC-FRP-MEDIA:Supply,installation testing and commissioning of Vertical Pressre type PSF Of MOC-FRP-.MEDIA Pebble,silex,sand)-24cft per standard specification etc… complete complying as perstandard specification(the make and quality should be approved by engineer-in-charge before installation)Approved Make; HoneydropISI Approved Equivalent.
ACF of MOC-FRP-MEDIA:Supply,installation testing and commissioning of Vertical Pressre type ACF Of MOC-FRP-MEDIA Pebble, silex, sand)-24 cft per standard specification etc. complete complying as perstandard specification (the make and quality should be approved by engineer-in-charge before installation) Approved Make; Honeydrop/ISI Approved Equivalent.
Electrical System : Supply ,installation testing and commissioning of Electrical system with a sheet thicknessof 1.6mm MOC: MS Powder Coated as per standard specification etc. complete complying as per standard specification(the make and quality should be approved by executiveengineer before installation) Approved Make:Componeents, siemens, L&T/HAVEELS/ISI Approved Equivalent. Cable Orbit/Finolex/Poly cab/ISI Approved
Pressure gauge
Flow Meter : Flow meter to be installed at the inlet to the treatment plant/urbine type flow meter with totalizing system at the outlet of carbon filter
Plumbing : Supply Installation & comissioning PLUMBING- Raw water Tank to Treat water Tank (PVC/GI/SS) Ball/Butterfly Valves/Non Return Valves
MS Cable Tray & Structural Supports : Fabrication, Supply & Erection of MS Structural support by using MS Angles & Flat for Panel Boards and cable Tray Supports duly with enamel painting. Fabrication, Supply and Fixing of 5mm thick chequered plate for cable trench cover slab.
Commissioning Chemicals : Supplying of commissioning chemicals for trial run of STP for one month as required quantity, inclusive of transport, handling charges and all taxes and duties etc. as directed by the Engineer-in- charge.
Description of Work / Item(s)
Amount
FIRE PUMPS AND ACCESSORIES
Supply, installation, testing and commissioning of Electrical Motor Driven Main Hydrant & Sprinkler Pump of horizontal centrifugal end suction top discharged type with mechanical seal and capable to deliver 2280 LPM at 90 Mtrs. Head, with all necessary accessories like bronze impeller, stainless steel shaft, coupling, coupling guard and base plate for pump, fabricated mild steel channel, foundation bolts. The pump shall be coupled to suitable electrical motor with speed of 2900 RPM, Electric supply 415V, 50 Hz.
Supply, installation, testing and commissioning of 150NB dia MS B class Exhaust Pipe with all accessories & 100mm fibreglass wool with GI hexagonal wire netting of 3/4" gauge 24 swg with 24 gauge cladding.
Supplying, installing, testing and commissioning of G.I. Pipes conforming to IS:1239 Pt - I Heavy grade Class-C for 25NB to 150NB and IS:3589 Gr 330 ERW Pipe(min 6.3mm thick) for 200NB & Above with suitable type of supports (Shall be fabricated by M.S. Channel / Angle / Flat for above 50mm dia), anchor fasteners, bolt, nuts, clamps, "U" bolts, Pipe fittings such as Reducers, Tees, elbows, flanges. including cutting, grooving, Welding, fixing in / on walls, ceiling by using suitable supports etc., as per drawings with painting as PO Red as per shade 536 of IS:5 for Above ground piping in Pump Room.
Supplying , installing, testing and commissioning of Cast Iron Gate Valves, OS&Y, Rising Spindle type, IS : 14846, PN 16 rating with following dia including necessary fittings like flanges, nut bolt, washer & gaskets etc. complete. 200NB
Supplying , installing, testing and commissioning of Cast Iron Wafer type, Butterfly valves of PN 16 rating with following dia including necessary fittings like flanges, nut bolt, washer & gaskets etc. complete.
Supplying , installing, testing and commissioning of Cast Iron, Y type Strainer of PN 16 rating with following dia including necessary fittings like flanges, nut bolt, washer & gaskets etc. complete.
Supplying , installing, testing and commissioning of Cast Iron, dual plate, Non Return Valve of PN 16 rating with following dia including necessary fittings like flanges, nut bolt, washer & gaskets etc. complete.
Supplying , installing, testing and commissioning of Rubber Expansion Bellows of PN 16 rating with following dia including necessary fittings like flanges, nut bolt, washer & gaskets etc. complete.
Supplying , installing, testing and commissioning of Pressure Switches of 0 to 16 Kgs. Range of suitable range with 15NB isolation valve, fittings such as unions / elbows / reducers etc.
Supplying , installing, testing and commissioning of Pressure Gauge 100mm dia of suitable range(0-16Kg/cm^2) complete with 15NB isolation valve and fittings such as unions / elbows / reducers etc.
Supplying , installing, testing and commissioning of MS fabricated Air Vessel, Dished end at pump room about 250mm dia and 1200mm height, 50NB BFV, MS stand with necessary cut off drain and air release arrangements and leading the drain pipe to the sump at pump room.
Supplying , installing, testing and commissioning of MCC Panel for 2 Nos. of Main Pump, 1 No. of Diesel Engine Pump & 2 Nos. of Jockey Pump, Main Pump Capacity is 2850 LPM at 90 Mtrs. Head, Diesel Pump Capacity is 2850 LPM at 90 Mtrs. Head & Jockey Pump Capacity is 180 LPM at 90 Mtrs. Head, panel consider as per KW of pump with on off switch & all necessary wiring work including control and instrumentation, etc. complete.
Supplying , installing, testing and commissioning of 4 way Fire brigade Breeching connection from tank with 150 mm dia NRV, Butterfly Valve & G.I. C Class pipe (Pipe max 12M long) with MS Cabinet.
Supplying , installing, testing and commissioning of 2 way Fire brigade Drow Out connection from tank with 150 mm dia Foot Valve & (Pipe max 12M long)
Supplying , installing, testing and commissioning of FRLS, PVC insulated PVC sheathed, steel armoured, aluminium / copper conductor, 1100v grade power cables. The cables shall be laid in tray / Hume pipe / in trenches/on walls/ floor etc. as required. Consider end connection of Gland etc.
3.5C x 120 sq.mm FRLS, Aluminium Armoured Cable for Main Pump
12C x 2.5 sq.mm FRLS, Copper Armoured Cable for Diesel Pump
3C x 16 Sqmm. FRLS, Aluminium Armoured Cable for Jockey Pump
2C x 1.5 Sqmm. FRLS, Copper Armoured Cable for Instrumentation
Supplying and installation of perforated G.I. sheet CABLE TRAY with necessary angle iron suspension supports, anchor fasteners etc. complete. Maximum height of suspension shall not exceed 500 mm. Size of the tray is 200mm x 50mm and 1.6mm thick.
Supplying and installation of G.I. EARTHING STRIPS of , strip shall be run on floor / ceiling / walls, from the equipment to the nearest Earth pit with necessary accessories as required. ( Earth pit shall be executed by other agencies).
50mm x 6mm thick
25mm x 6mm thick
Supplying and installation of STRUCTURAL STEEL SUPPORTS such as MS channels, angles, flats, rods as required at site with anchor fasteners, clamps, threaded rods, nuts, bolts, washers etc. complete with painting.
EXTERNAL FIRE HYDRANT SYSTEM
Supplying, installing, testing and commissioning of G.I. Pipes conforming to IS 1239 Pt – I Heavy grade Class-C for 25NB to 150NB and IS:3589 Gr. 330, Min 6.3mm thick for above 150NB with suitable type of supports (Shall be fabricated by M.S. Channel / Angle / Flat ), anchor fasteners, bolt, nuts, clamps, "U" bolts, Pipe fittings such as Reducers, Tees, elbows, flanges. including cutting, grooving, Welding, fixing in / on walls, ceiling by using suitable supports etc., as per drawings. Above Ground Pipe
Supplying, installing, testing and commissioning of G.I. Pipes conforming to IS 1239 Pt – I Heavy grade Class-C for 25NB to 150NB and IS:3589 Gr. 330, Min 6.3mm thick for above 150NB with suitable type of supports (Shall be fabricated by M.S. Channel / Angle / Flat ), anchor fasteners, bolt, nuts, clamps, "U" bolts, Pipe fittings such as Reducers, Tees, elbows, flanges. including cutting, grooving, Welding, fixing in / on walls, ceiling by using suitable supports etc., as per drawings. 4 mm thick polymeric corrosion protection tape conforming to IS 10221 and painting with bituminous paint after laying and testing to 13.5 Kg / Sq. cm hydraulic pressure after installation etc. as per specification complete as required. For Under Ground Pipe 150NB
Supplying, installing, testing and commissioning of Hume Pipe for Under Ground Pipe NP2 with Collar & accessories Complete. 350NB
Supplying, installing, testing and commissioning of Stainless Steel Single Hydrant Valve as per IS 5290 with 63 mm dia instantaneous outlet of 80 mm dia flanged inlet ,Blank caps , chain and hand wheels etc. complete.
Supplying, installing, testing and commissioning of 15 M long, 1 length 63mm dia RRL Hose conforming to IS 636 Type A with instantaneous S.S. couplings and Hoses shall be stored inside the hose cabinet.
Supplying, installing, testing and commissioning of 63mm dia instantaneous pattern S.S. Branch Short Pipe, 20 mm dia nozzle conforming to IS 903, suitable for inter connection to hose pipe coupling complete as required.
Supplying & installing of weather proof lockable cabinet of size not less than 750x600x250mm made out of MS sheet of 16 gauge thickness having central opening and 4 mm thick glazed glass doors (Two nos.) suitably marked “FIRE” on the outside.
Supplying , installing, testing and commissioning of Cast Iron Wafer type, Butterfly valves of PN 16 rating with following dia including necessary fittings like flanges, nut bolt, washer & gaskets etc. complete. 150NB
Supplying , installing, testing and commissioning of 4 Way Fire Brigade Siamese Connection in Mains near suitable location with NRV-150NB, Butterfly valve-150NB & cabinet with all other accessories located in Hydrant Ring.
Supplying, installing, testing and commissioning of Stainless Steel 6mm thk. Orifice Plate for External Hydrant System
Supplying & installing of STRUCTURAL STEEL SUPPORTS such as MS channels, angles, flats, rods as required at site with anchor fasteners, clamps, threaded rods, nuts, bolts, washers etc. complete with painting.
INTERNAL FIRE HYDRANT SYSTEM
Supplying, installing, testing and commissioning of G.I. Pipes conforming to IS 1239 Pt – I Heavy grade Class-C for 25NB to 150NB and IS:3589 Gr. 330, Min 6.3mm thick for above 150NB with suitable type of supports (Shall be fabricated by M.S. Channel / Angle / Flat ), anchor fasteners, bolt, nuts, clamps, "U" bolts, Pipe fittings such as Reducers, Tees, elbows, flanges. including cutting, grooving, Welding, fixing in / on walls, ceiling by using suitable supports etc., as per drawings. Above Ground Pipe 100NB
Supplying, installing, testing and commissioning of Stainless Steel Single Hydrant Valve as per IS 5290 with 63 mm dia instantaneous outlet of 80 mm dia flanged inlet ,Blank caps , chain and hand wheels etc. complete.
Supplying, installing, testing and commissioning of First aid Hose reel drum of 180° swinging type with 20mm dia Rubber braided hose of 30 Mtrs. length with Ball Valve and 6mm diameter SS Shut off nozzle, complete. The hose reel shall conforming to IS 884
Supplying & installing of 15 M long, 1 length 63mm dia RRL Hose conforming to IS 636 Type A with instantaneous S.S. couplings and Hoses shall be stored inside the hose cabinet.
Supplying, installing, testing and commissioning of 63mm dia instantaneous pattern S.S. Branch Short Pipe, 20 mm dia nozzle conforming to IS 903, suitable for inter connection to hose pipe coupling complete as required.
Supplying & installing of weather proof lockable cabinet of size not less than 750x600x250mm made out of MS sheet of 16 gauge thickness having central opening and 4 mm thick glazed glass doors (Two nos.) suitably marked “FIRE” on the outside.
Supplying , installing, testing and commissioning of Cast Iron Wafer type, Butterfly valves of PN 16 rating with following dia including necessary fittings like flanges, nut bolt, washer & gaskets etc. complete. 100NB
Supplying , installing, testing and commissioning of GM Air Release Valve 25mm dia with Ball Valve with of & accessories.
Supplying, installing, testing and commissioning of Stainless Steel 6mm thk. Orifice Plate for External Hydrant System
Supplying & installing of STRUCTURAL STEEL SUPPORTS such as MS channels, angles, flats, rods as required at site with anchor fasteners, clamps, threaded rods, nuts, bolts, washers etc. complete with painting.
TERRACE LEVEL HYDRANT SYSTEM
Supplying, installing, testing and commissioning of G.I. Pipes conforming to IS 1239 Pt – I Heavy grade Class-C for 25NB to 150NB and IS:3589 Gr. 330, Min 6.3mm thick for above 150NB with suitable type of supports (Shall be fabricated by M.S. Channel / Angle / Flat ), anchor fasteners, bolt, nuts, clamps, "U" bolts, Pipe fittings such as Reducers, Tees, elbows, flanges. including cutting, grooving, Welding, fixing in / on walls, ceiling by using suitable supports etc., as per drawings. Above Ground Pipe 100NB
Supplying , installing, testing and commissioning of Cast Iron Wafer type, Butterfly valves of PN 16 rating with following dia including necessary fittings like flanges, nut bolt, washer & gaskets etc. complete. 100NB
Supplying , installing, testing and commissioning of Cast Iron Non Return Valve of PN 16 rating with following dia including necessary fittings like flanges, nut bolt, washer & gaskets etc. complete. 100NB
Supplying , installing, testing and commissioning of Pressure gauge 100mm dia of suitable range(0-16Kg/cm^2) complete with 15NB isolation valve and fittings such as unions / elbows / reducers etc.
Supplying & installing of STRUCTURAL MS SUPPORTS such as MS channels, angles, flats, rods as required at site with anchor fasteners, clamps, threaded rods, nuts, bolts, washers etc. complete with painting.
PORTABLE FIRE EXTINGUISHER, SAND BUCKET & SIGNAGES
Supplying , installing of Portable Fire Extinguisher with all necessary accessories.
ABC Dry Chemical 6 Kgs. Capacity
CO2 - 4.5 Kgs. Capacity
Supply & installing in position the following type of sign boards made out of 3mm thick "Opaque" PVC foam board with computer cut, PVC non-reflective self adhesive vinyl painted foam board, complete with mirror fasteners.
Signage with printed "IN CASE OF FIRE, USE STAIRS UNLESS INSTRUCTED OTHERWISE" of 1.5cm height letters in red with white back ground. The size of the board shall be 25cm x 30 cm and shall be fixed at the height of 2 mts. from finished floor near Manual call points.
Floor identification Signage ( i.e., GROUND FLOOR …etc.) at each stair enclosure on every floor, indicating the floor number in words, lettering size shall be 7.5 cm with contrasting colour from back ground. Size shall be 15cm x 60cm.
SPRINKLER SYSTEM
Supplying, installing, testing and commissioning of G.I. Pipes conforming to IS 1239 Pt – I Heavy grade Class-C for 25NB to 150NB and IS:3589 Gr. 330, Min 6.3mm thick for above 150NB with suitable type of supports (Shall be fabricated by M.S. Channel / Angle / Flat ), anchor fasteners, bolt, nuts, clamps, "U" bolts, Pipe fittings such as Reducers, Tees, elbows, flanges. including cutting, grooving, Welding, fixing in / on walls, ceiling by using suitable supports etc., as per drawings. Above Ground Pipe
25 mm nominal dia
32 mm nominal dia
40 mm nominal dia
50 mm nominal dia
65 mm nominal dia
80 mm nominal dia
100 mm nominal dia
Supplying , installing, testing and commissioning of Sprinkler Alarm Valve (ICV) of following size including necessary fittings like Companion flanges, nut ,bolt & gaskets etc. complete. 150NB
Supplying , installing, testing and commissioning of Cast Iron Wafer type, Butterfly valves of PN 16 rating with following dia including necessary fittings like flanges, nut bolt, washer & gaskets etc. complete. 100NB
Supplying , installing, testing and commissioning of GM Air Release Valve 25mm dia with Ball Valve with of & accessories.
Supplying , installing, testing and commissioning of Flow Switch of following dia including necessary fittings like Companion flanges, nut ,bolt & gaskets etc. complete. 100NB
Supplying , installing, testing and commissioning of 25NB Sprinkler test & drain valve with accessories
Supplying , installing, testing and commissioning of Pressure Gauge 100mm dia of suitable range(0-16Kg/cm^2) complete with 15NB isolation valve and fittings such as unions / elbows / reducers etc.
Supplying , installing, testing and commissioning of Standard Response & Standard Coverage Sprinklers with rosset plate with all accessories. Pendent Sprinkler K80, 68 deg. C
Supplying , installing, testing and commissioning of SS Braided Flexible Drop for Pendent Sprinkler. End Connection 15mm x 1500mm Long
Supplying & installation of STRUCTURAL STEEL SUPPORTS such as MS channels, angles, flats, rods as required at site with anchor fasteners, clamps, threaded rods, nuts, bolts, washers etc. complete with painting.
Description of Work / Item(s)
Amount
VRV/VRF
VRV/VRF SYSTEM - HIGH SIDE Supply, Installation,gas charging, testing and commissioning of Modulating outdoor units(Top discharge), with multi scroll/Rotary compressors (minimum two compressors) with one capacity controlling compressor, special pre-coated fins, panel, corrosion resistant , coated condenser, inverter based condenser fan mounted as indicated in the drawing, electrical & microprocessor panel, isolating valves and all the necessary accessories for proper functioning of the units, having following approximate capacities. Indicate for all port charges, port handling charges, other local duties, loading, transportation /insurance up to site, octroi charges and all other taxes and incidentals complete till delivered at site. Customs duty and countervailing duty for the above imported equipment. Receiving at site above imported equipment, unloading, storing, handling hoisting, installing in position, effecting connections, anchoring, grouting testing and commissioning above equipment including supplying and installing all necessary indigenous accessories as required .
20 HP Outdoor Unit
26 HP Outdoor Unit
28 HP Outdoor Unit
VRF/VRV INDOOR UNITS Supply, installation, testing & commissioning of VRF Cassette type Indoor units (IDU) with R410A refgrigerent complete with filter section Four speed evaporator fan motor, fan, direct expansion cooling coil, electronic expansion valve,Cordedless remote ,cleanable filter and insulated drain pan enclosed in plastic casing.
1.0 TR cassette Type unit
1.5 TR cassette Type unit
2.0 TR cassette Type unit
2.5 TR cassette Type unit
3.0 TR cassette Type unit
4.0 TR cassette Type unit
Supply, installation, testing & commissioning of VRF 1- Way Cassette type Indoor units (IDU) with R410A refgrigerent complete with filter section Four speed evaporator fan motor, fan, direct expansion cooling coil, electronic expansion valve,Cordedless remote ,cleanable filter and insulated drain pan enclosed in plastic casing.
1.0 TR 1- Way cassette Type unit
2.0 TR 1- Way cassette Type unit
Supply, installation, testing & commissioning of VRF Treated fresh air Indoor units (IDU) with R410A refgrigerent complete with MERV-13 Filter section , fan, direct expansion cooling coil, electronic expansion valve, Cordedless remote, Canvas connection , cleanable filter and insulated drain pan enclosed in plastic casing.
3.5 TR Treated Fresh Air unit
5.5 TR Treated Fresh Air unit
Supply and Installation of Branch Kit Joints/Refnet connections with moulded factory supplied insulation for liquid&suction line branch offset(1set=1 in liquid line + 1 in suction Line)
Supply and Installation of Branch Kit Joints/Refnet connections for outdoor unit with moulded factory supplied insulation for liquid&suction line branch offset(1set=1 in liquid line + 1 in suction Line)
VRV/VRF SYSTEM - LOW SIDE
Supply, Installation and Testing of 18G hard drawn refrigerant piping, fittings with 19mm thick Class "O" tubular nitrile rubber insulation and finished . Complete piping workmanship to be carried out as per recommended practice. Scope includes all refrigerant pipes shall be properly supported using Rods,Anchor bolts, Threaded rods,etc.
6.5 MM DIA - 1/4 "
9.5 MM DIA - 3/8 "
12.7 MM DIA - 1/2 "
15.9 MM DIA - 5/8"
19.1 MM DIA - 3/4"
22.2 MM DIA -7/8"
28.6 MM DIA - 1 1/8"
34.9 MM DIA - 1 3/8"
41.3 MM DIA - 1 5/8"
44.5 MM DIA - 1 3/4"
Supply Installation of PVC drain pipe with 9mm thick Nitrile rubber tubular pipe insulation with necessary supports.
25mm dia
32mm dia
50mm dia
75mm dia
Supply and filling of R410A Refrigerant Gas
N2 pressure testing ,Testing & Commissioning
Control wiring between indoor and outdoor units with PVC Conduit.
Supply, Instalaltion, balancing and commissioning of factory fabricated GSS sheet metal rectangular complete with neoprene rubber gasket . 24 G
Thermal insulation : Supply &fixing of 9 mm thick Class O nitrile rubber insulation with antimicrobial property with adhesive as per the recommendation of the manufacturer with density 45-55kg/m3.
Acoustic insulation: Supply &fixing of 10 mm thick Class 1 acoustic nitrile rubber insulation with antimicrobial property with adhesive as per the recommendation of the manufacturer with density 140-180kg/m3
Supply, Instalaltion, balancing and commissioning of factory fabricated GSS sheet metal round ducting with complete 6mm nitrile rubber inner insulation . 26 G
Supply, Instalaltion, balancing and commissioning of Spigot damper with necessary supports . 75 MM DIA
Supply, Instalaltion, balancing and commissioning of Insulated flexible duct with necessary supports. 75 MM DIA
Supply of Cosmic Make Ext. Al. Powder Coated Fresh Air Louver With Bird Screen & GI Duct Damper 18G Frame With 20G Blade With 150 mm Depth With Manual Handle type.(600 x 600)
Supply,Installation, Testing & Commissioning of CO2 Sensor, Sensor Type - Co2: NDIR (Non-dispersive infrared) Temperature: 10 kOhm type 3 thermistor. Measurement Range - 0 - 2000 PPM, Measurement accuracy - (+/-) 1.5%, Mounting Support - Duct, Analog output Type - 4 - 20 mA, 0-5 V DC, 0 to 10 V DC , Output Type - Analog Resistive output, CE & UL certified.
Description of Work / Item(s)
Amount
IMPORTANT GENERAL NOTES: 1.Rate shall Including CEIG, TANGEDCO Approval and safety Certificate for all the External and internal electrical works and electrical equipment's.
11KV HT VCB THREE PANEL - OUTDOOR TYPE (Near RMG)
HT CABLE & TERMINATION, etc… Supply and laying of following size 11kV HT XLPE insulated armoured aluminium power cable . 3C x 185 sq. mm Al, Ar, XLPE 11kV HT Cable
supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of XLPE aluminium conductor cable of 11 KV grade as required. 3C x 185 sq. mm Al,11kV HT Cable
FENCING YARD: OUTDOOR Fencing yard for outdoor 11kV HT Panel, Transformer area. (Plan Area) Supply and laying of 40mm size aggregate (granite jelly ) for a height of 150 mm and 75 mm river sand cushioning below the above mentioned 40 mm aggregate at with in the transformer yard as per the norms of CEIG (Fencing details of height of 2.1 mtr with chain link mesh made of 10 SWG GI wire with mesh size of 50mm x 50mm welded to angle iron frame made of 50mm x 50mm X 5 mm size on all four sides and 1 no. horizontal intermediate member of 50mm x 50mm x 5mm welded to 25mm x 5mm flat to form 'T' section (The angle iron frame shall be fabricated in section of width not more than 1.5 mtr and assembled at site to form the required fencing). The vertical members of frame shall be extended by 75cm for erection in ground, including erections of the angle iron frames in 1:3:6 cement concrete.).
SUB HEAD -2 : 1000 kVA TRANSFORMER: Design, manufacture, Supply, installation, testing, commissioning of 1000kVA (oil Cooled) Level-1 low loss out door type Transformer, 3phase, 50Hz, 11kV / 433V, DELTA / STAR, Vector group: DYn11, Insulation class: A, Insulation level: 75kVp / 28kVrms, Design ambient 50 Deg C, Temperature rise above ambient less than 90 Deg C, Copper winding, CRGO core lamination, On load tap changer range from +5 % to -15 % @ 1.25 % per steps with 16 steps / 17 positions, RTCC + AVR Panel, Cooling type: ONAN (Oil cooling), Powder coated sheet steel enclosure IP23 protection. The transformer shall be provided with cable termination box on incomer side to terminate 1R- 11KV 3 core 240 Sqmm XLPE (E) HT cable and suitable for terminating 1600A TPN Aluminium Sandwich bus duct at Outgoing side and all the accessories and the transformer will confirm to IS 1180, IS 2026 and IS 11171.
SUB HEAD -3 : BUSDUCT:
Supply, Installation, Testing & Commissioning of 3P+100% Neutral 4W, 1600A ALUMINIUM Conductor Sandwich Design BUSDUCTS with external Copper earth flat 25x3mm 2runs. Bus duct Enclosure should be minimum 1.5mm GI with RAL7035 shade epoxy painted / powder coated. Bus duct to be designed based on Temp Rise only not as per Current density. Class 'F' insulation (Ambient 40 Deg C + rise 55Deg C) Outdoor IP65 with Canopy. (Transformer & DG Set.)
90 Deg Bends - Provision Cost
Flange end - Provision Cost
Copper Flexibles for 4W 1600A Termination with Links
Adapter Box
Phase Transposition Unit - Provision Cost
Rubber Bellows (for DG end only)
Expansion Joints (for more than 40mtrs Straight length only) - Provision Cost
SUB HEAD -4: RISING:
Supply, Installation, Testing & Commissioning of 3P+100% Neutral 4W, 800A ALUMINIUM Conductor sandwich Design Rising Mains with external earth flat of Copper 25x3mm 2runs.Rising Main Enclosure should be minimum1.5mm GI with RAL7035 shade epoxy painted / powder coated. Rising Main to be designed based on Temp Rise only not as per Current density. Class 'F' insulation (Ambient 40 Deg C + rise 55Deg C) Indoor IP55 with Plug in Points at every 500mm - 850mm intervals. Fire Barriers to be provided at every floor crossings. (RM-1 & 2)
Vertical Brackets (for every 2mtrs)
800A Rigid Support
800A Spring Support
End Cover
End Feed Unit with 800A FIXED TYPE ACB
Plug in Box with 250A MCCB & ROHM
Plug in Box with 125A MCCB & ROHM
SUB HEAD -5 : LT PANEL BOARD
Supply, Installation, Testing and Commissioning of Indoor type LT Switchboards, Floor mounting type, Bottom/Top entry. Refer enclosed SLD. General Requirement of LT Panel Board : 1) Refer Indian standard Specification : IS 2419, IS/IEC 61439-0,1,2. IS/IEC 60947-1 with latest revision. 2) Enclosure: Compartmentalized Single front CRCA Doors- 2mm, Body- 2mm, Gland- 3mm, Covers and partitions-1.6mm. 3) Protection Class: IP52 for Indoor / IP55 with weather proof enclosure for outdoor. 4) Bus bars: Electrolytic grade conductivity as per standard IS 5082 with latest revision. 5) Bubs bar Material : Aluminium / Copper - As per SLD. 6) Bus bar supports: DMC/ FRP/ SMC. 7) Bus bar joints: Shrouded / Tinned . 8) Breakers : up to 160A Thermal Magnetic and 200 & above Microprocessor type MCCB or as specified. 9) Protection releases: As per SLD (Adjustable over current & short circuit unless otherwise specified). 10) Ics = Icu 100% for all breakers. 11) Utilization category: All MCCB / ACB's shall be Cat : A except ACB's for Lighting & Raw power input distribution panel shall be with Cat : B. 12) Louvers : Busbar chamber shall have louvers with fine mesh inside. 13) Shade : Epoxy powder coated RAL 7032.
14) Design : Form 4A Type-6 construction with common cable chambers. No live parts allowed in cable chambers. 15) Cable entry: Top / Bottom As per site condition. 16) SPD should have N/O contact for remote indication. 17) Bus bar insulation: The bus bar shall be covered with heat shrinkable PVC sleeves at all non contact points in colour of red, yellow, blue and black and the arranged in accordance with IS-5578 with latest revision. 18) All the breakers shall have potential free aux NO/NC contacts for ON,OFF & TRIP Indications and BMS monitoring. 19) All the breakers shall have spreaders/phase separators/ RHOM / Pad lock / Door lock / trip free. 20) All the AHU/ VRF / VRV feeders shall be provided with shunt trip. 21) Insulated shrouding shall be provided for live parts. 22) FRLS PVC copper wires shall be used for control wiring. 23) CT's shall be provided with shorting terminals. 24) MFM shall be BMS Compatible with RS485 Port- MODBUS/open protocol.
MAIN MV PANEL: Main MV Panel of compartmentalised, powder coated cubical panel board, free standing type, suitable for 3 Phase, 415 volts, 50 Hz, AC Supply, fabricated with CRCA sheet steel not less than 2 mm thick, dust and vermin proof, with ventilation louvers, cable alleys, detachable gland plate, ISMC 75 Channel Iron base frame, with following capacity, insulated Aluminium busbar, Incoming and out going switch gears, meters, connection, interconnection, earthing etc. complete as reqd.
INCOMING i) 1600A, 4Pole, electrically draw out type(EDO), Air circuit breaker (ACB),microprocessor based, Icw 50kA (1 sec), 415V, Uimp = 12kV, 100% Neutral, rating confirming to IS/IEC 60947-2. as amended up to date complete with Independent manual spring closing mechanism with Microprocessor release for over current, earth fault & short circuit protection and communication module for Ethernet (Modbus TCP/IP) provision to compatibility with IBMS and all other accessories as required. (As per SLD) Transformer Incomer shall have ii) Digital multifunction meter class 1.0 accuracy, with Rs 485 port output for IBMS integration with read (V,A,F,PF, kW, kVA, kVAR, kWh, kVAh, kVARh) etc. with - 1No. iii) 1600A/5A CL.1 accuracy, 15VA metering CT - 3 Nos. iv) Protection CT 160A/5A CL. 5P10 accuracy, 15VA Protection CT -3 Nos. v) IDMT Over current, Earth fault relay, Under voltage, Over voltage relay with instantaneous element - 1Set. vi) 'RYB' and 'ON','OFF','TRIP' indication lamps connected with suitable control fuse and MCB - 1 Set. vii) 1600A/5A CT with CL:5P10,15VA with suitable control fuse For APFCR RELAY in the capacitor panel - 1 Set. viii) Shunt trip coil 220V AC power rating - 1 No. ix) Bus duct entry flange provision on top suitable for 1600A bus duct. BUS BAR: 415V, 50Hz, 3Phase, 4Wire, Aluminium bus bars of minimum of 2000 Amps capacity per PH: 2Runs x 150 x 10mm, NE: 2Run x 150 x 10mm Aluminium bus bars (vertical and horizontal) with heat shrinkable coloured sleeves and i/c DMC/ SMC bus bars supports at required intervals complete etc. for withstanding fault current of 50 KA /1Sec. BUS COUPLER - 1 No. i) 1600A, 4Pole, electrically draw out type (EDO), Air circuit breaker (ACB),microprocessor based, Icw 50kA (1 sec), 415V, Uimp = 12kV, 100% Neutral, rating confirming to IS/IEC 60947-2. as amended up to date complete with Independent manual spring closing mechanism without tripping relays and mechanical door interlock and with communication module for Ethernet (Modbus TCP/IP) provision to compatibility with IBMS and all other accessories as required. Bus coupler shall have ii) 'RYB', 'ON','OFF','TRIP' and Bus-1 & 2. 'ON','OFF', indication lamps connected with suitable control fuse and MCB - 1 Set. iii) Shunt trip coil 220V AC power rating - 1 No.
910 kVA DG Set INCOMERS - 1 Nos. i) 1600A, 4Pole, electrically draw out type (EDO), Air circuit breaker (ACB),microprocessor based, Icw 50kA (1 sec), 415V, Uimp = 12kV, 100% Neutral, rating confirming to IS/IEC 60947-2. as amended up to date complete with Independent manual spring closing mechanism with Microprocessor release for over current, earth fault & short circuit protection and communication module for Ethernet (Modbus TCP/IP) provision to compatibility with IBMS and all other accessories as required. Incomer shall have ii) Digital multifunction meter class 1.0 accuracy, with Rs 485 port output for IBMS integration with read (V,A,F,PF, kW, kVA, kVAR, kWh, kVAh, kVARh) etc. with - 1No. iii) 1600A/5A CL.1 accuracy, 15VA metering CT - 3 Nos. iv) Protection CT 1600A/5A CL. 5P10 accuracy, 15VA Protection CT -3 Nos. v) IDMT Over current, Earth fault relay, Under voltage, Over voltage relay with instantaneous element - 1Set. vi) 'RYB' and 'ON','OFF','TRIP' indication lamps connected with suitable control fuse and MCB - 1 Set. vii) Shunt trip coil 220V AC power rating - 1 No. OUTGOINGS:- OUT GOING SECTION (BEFORE BUS COUPLER): 3 Sets. 800A, 4Pole, electrically draw out type(EDO), Air circuit breaker (ACB),microprocessor based, Icw 50kA (1 sec), 415V, Uimp = 12kV, 100% Neutral, rating confirming to IS/IEC 60947-2. as amended up to date complete with Independent manual spring closing mechanism with Microprocessor release for over current, earth fault & short circuit protection and communication module for Ethernet (Modbus TCP/IP) provision to compatibility with IBMS and all other accessories as required. (Rising Main-1,APFCR Panel, Spare) 2 Set. 630A, 4Pole, MCCB to having single frame size and common accessories, 50kA (Ics), 415V, Microprocessor release for over current, earth fault & short circuit protection, with rotary operating handle mechanism front drive kit, Spreader terminals and communication module for Ethernet (Modbus TCP/IP) provision to compatibility with SCADA and all other accessories as required. (provide extended busbar for out going cable termination). (AC VRF Panel, Fire Pump panel) 3 Set. 250A, 4Pole, MCCB to having single frame size and common accessories, 50kA (Ics), 415V, Microprocessor release for over current, earth fault & short circuit protection, with rotary operating handle mechanism front drive kit, Spreader terminals and communication module for Ethernet (Modbus TCP/IP) provision to compatibility with SCADA and all other accessories as required. (provide extended busbar for out going cable termination) (Lift panel,UPS-3, Spare).
OUT GOING SECTION (AFTER BUS COUPLER): 1 Set. 800A, 4Pole, electrically draw out type(EDO), Air circuit breaker (ACB),microprocessor based, Icw 50kA (1 sec), 415V, Uimp = 12kV, 100% Neutral, rating confirming to IS/IEC 60947-2. as amended up to date complete with Independent manual spring closing mechanism with Microprocessor release for over current, earth fault & short circuit protection and communication module for Ethernet (Modbus TCP/IP) provision to compatibility with IBMS and all other accessories as required. (Rising Main-2) 1 Set. 630A, 4Pole, MCCB to having single frame size and common accessories, 50kA (Ics), 415V, Microprocessor release for over current, earth fault & short circuit protection, with rotary operating handle mechanism front drive kit, Spreader terminals and communication module for Ethernet (Modbus TCP/IP) provision to compatibility with IBMS and all other accessories as required. (provide extended busbar for out going cable termination) (Spare). 4 Set. 250A, 4Pole, MCCB to having single frame size and common accessories, 50kA (Ics), 415V, Microprocessor release for over current, earth fault & short circuit protection, with rotary operating handle mechanism front drive kit, Spreader terminals and communication module for Ethernet (Modbus TCP/IP) provision to compatibility with IBMS and all other accessories as required. (provide extended busbar for out going cable termination) (Pump Panel, Common Panel, UPS-1, UPS-2). All Out going shall have i) Digital multifunction meter class 1.0 accuracy, with Rs 485 port output for IBMS integration with read (V,A,F,PF, kW, kVA, kVAR, kWh, kVAh, kVARh) etc. with - 1No. ii) 800A/5A CL.1 accuracy, 15VA metering CT - 3 Nos. iii) 630A/5A CL.1 accuracy, 15VA metering CT - 3 Nos. iv) 250A/5A CL.1 accuracy, 15VA metering CT - 3 Nos. v) 'RYB' and 'ON','OFF','TRIP' indication lamps connected with suitable control fuse and MCB - 1 Set. EARTH Copper Earth strip of size 2Runs x 25 x 6 mm for full width of board with 2 termination points. (MAIN MV PANEL)
Common Panel -GF: Main Power panel of compartmentalized, powder coated cubical panel board, free standing type, suitable for 3 Phase, 415 volts, 50 Hz, AC Supply, fabricated with CRCA sheet steel not less than 2 mm thick, dust and vermin proof, with ventilation louvers, cable alleys, detachable gland plate, ISMC 75 Channel Iron base frame, with following capacity, insulated Aluminium busbar, Incoming and out going switch gears, meters, connection, interconnection, earthing etc. complete as reqd. INCOMING Incomer 250A, 415V, 50 Hz, 4 Pole MCCB, 36 KA (Ics =100% Icu) (Micro processor based Thermal magnetic OL / SC Adjustable protection) with mechanical interlock and with extended Front drive kit and space provision to terminate 4C x 50 sq.mm AYFY UG cable. Instrument panel for Incomer - RYB LED lamps, and ON/OFF indication lamp with associated MCB's, fuses etc. Instrument panel for Digital multi function meter suitable for measuring AC voltage, Current, KWH, KW, PF, Frequency, Harmonies etc. BUSBAR Busbar in separate chamber with sealing arrangements with the following busbars 300A Capacity PH: 3Runs x 40 x 10mm, NE: 1Run x 40 x10mm Aluminium bus bars (vertical and horizontal) with suitable SMC supports. OUTGOINGS:- 7 Sets. 63A, 415V, 50 Hz, 4P MCCB, 25 KA, Thermal magnetic based OL & SC relay and with Front drive kit. All Out going shall have i) Digital multifunction meter class 1.0 accuracy, with Rs 485 port output for IBMS integration with read (V,A,F,PF, kW,) etc. with - 1No. ii) 63A/5A CL.1 accuracy, 15VA metering CT - 3 Nos. iii) 'ON','OFF','TRIP' indication lamps connected with suitable control fuse and MCB - 1 Set. EARTH Copper Earth strip of size 2Runs x 25 x 3 mm for full width of board with 2 termination points. Floor Common panel
All Floor Common Panel: Main Power panel of compartmentalized, powder coated cubical panel board, free standing type, suitable for 3 Phase, 415 volts, 50 Hz, AC Supply, fabricated with CRCA sheet steel not less than 2 mm thick, dust and vermin proof, with ventilation louvers, cable alleys, detachable gland plate, ISMC 75 Channel Iron base frame, with following capacity, insulated Aluminium busbar, Incoming and out going switch gears, meters, connection, interconnection, earthing etc. complete as reqd. INCOMING Incomer 1 & 2 : 2sets. 125A, 415V, 50 Hz, 4 Pole MCCB, 36 KA (Ics =100% Icu) (Micro processor based Thermal magnetic OL / SC Adjustable protection) with mechanical interlock and with extended Front drive kit and space provision to terminate 4C x 50 sq.mm AYFY UG cable. Instrument panel for Incomer - RYB LED lamps, and ON/OFF indication lamp with associated MCB's, fuses etc. Instrument panel for Digital multi function meter suitable for measuring AC voltage, Current, KWH, KW, PF, Frequency, Harmonies etc. BUSBAR Busbar in separate chamber with sealing arrangements with the following busbars 200A Capacity PH: 3Runsx 40 x 6mm, NE: 1Run x 40 x 6mm Aluminium bus bars (vertical and horizontal) with suitable SMC supports. OUTGOINGS:- 7 Sets. 63A, 415V, 50 Hz, 4P MCCB, 25 KA, Thermal magnetic based OL & SC relay and with Front drive kit. All Out going shall have i) Digital multifunction meter class 1.0 accuracy, with Rs 485 port output for IBMS integration with read (V,A,F,PF, kW,) etc. with - 1No. ii) 63A/5A CL.1 accuracy, 15VA metering CT - 3 Nos. iii) 'ON','OFF','TRIP' indication lamps connected with suitable control fuse and MCB - 1 Set. EARTH Copper Earth strip of size 2Runs x 25 x 3 mm for full width of board with 2 termination points. Floor Common panel
Pump Panel: Main Power panel of compartmentalized, powder coated cubical panel board, free standing type, suitable for 3 Phase, 415 volts, 50 Hz, AC Supply, fabricated with CRCA sheet steel not less than 2 mm thick, dust and vermin proof, with ventilation louvers, cable alleys, detachable gland plate, ISMC 75 Channel Iron base frame, with following capacity, insulated Aluminium busbar, Incoming and out going switch gears, meters, connection, interconnection, earthing etc. complete as reqd. INCOMING Incomer 250A, 415V, 50 Hz, 4 Pole MCCB, 36 KA (Ics =100% Icu) (Micro processor based Thermal magnetic OL / SC Adjustable protection) with mechanical interlock and with extended Front drive kit and space provision to terminate 4C x 50 sq.mm AYFY UG cable. Instrument panel for Incomer - RYB LED lamps, and ON/OFF indication lamp with associated MCB's, fuses etc. Instrument panel for Digital multi function meter suitable for measuring AC voltage, Current, KWH, KW, PF, Frequency, Harmonies etc. BUSBAR Busbar in separate chamber with sealing arrangements with the following busbars 300A Capacity PH: 3Runs x 40 x10mm, NE: 1Run x 40 x10mm Aluminium bus bars (vertical and horizontal) with suitable SMC supports. OUTGOINGS:- 1 Sets. 125A, 415V, 50 Hz, 4P MCCB, 25 KA, Thermal magnetic based OL & SC relay and with Front drive kit. 1 Sets. 63A, 415V, 50 Hz, 4P MCCB, 25 KA, Thermal magnetic based OL & SC relay and with Front drive kit and DOL Starter. 6 Sets. 40A, 415V, 50 Hz, 4P MCCB, 25 KA, Thermal magnetic based OL & SC relay and with Front drive kit and DOL Starter. All Out going shall have i) Digital multifunction meter class 1.0 accuracy, with Rs 485 port output for IBMS integration with read (V,A,F,PF, kW,) etc. with - 1No. ii) 125A/5A CL.1 accuracy, 15VA metering CT - 3 Nos. iii) 63A/5A CL.1 accuracy, 15VA metering CT - 3 Nos. iv) 40A/5A CL.1 accuracy, 15VA metering CT - 3 Nos. v) 'ON','OFF','TRIP' indication lamps connected with suitable control fuse and MCB - 1 Set. EARTH Copper Earth strip of size 2Runs x 25 x 3 mm for full width of board with 2 termination points. Pump panel
Main Lift Panel: Main Power panel of compartmentalized, powder coated cubical panel board, free standing type, suitable for 3 Phase, 415 volts, 50 Hz, AC Supply, fabricated with CRCA sheet steel not less than 2 mm thick, dust and vermin proof, with ventilation louvers, cable alleys, detachable gland plate, ISMC 75 Channel Iron base frame, with following capacity, insulated Aluminium busbar, Incoming and out going switch gears, meters, connection, interconnection, earthing etc. complete as reqd. INCOMING Incomer 250A, 415V, 50 Hz, 4 Pole MCCB, 36 KA (Ics =100% Icu) (Micro processor based Thermal magnetic OL / SC Adjustable protection) with mechanical interlock and with extended Front drive kit and space provision to terminate 4C x 50 sq.mm AYFY UG cable. Instrument panel for Incomer - RYB LED lamps, and ON/OFF indication lamp with associated MCB's, fuses etc. Instrument panel for Digital multi function meter suitable for measuring AC voltage, Current, KWH, KW, PF, Frequency, Harmonies etc. BUSBAR Busbar in separate chamber with sealing arrangements with the following busbars 300A Capacity PH: 3Runs x 40 x10mm, NE: 1Run x 40 x 10mm Aluminium bus bars (vertical and horizontal) with suitable SMC supports. OUTGOINGS:- 5 Sets. 63A, 415V, 50 Hz, 4P MCCB, 25 KA, Thermal magnetic based OL & SC relay and with Front drive kit. All Out going shall have i) Digital multifunction meter class 1.0 accuracy, with Rs 485 port output for IBMS integration with read (V,A,F,PF, kW,) etc. with - 1No. ii) 63A/5A CL.1 accuracy, 15VA metering CT - 3 Nos. iii) 'ON','OFF','TRIP' indication lamps connected with suitable control fuse and MCB - 1 Set. EARTH Copper Earth strip of size 2Runs x 25 x 3 mm for full width of board with 2 termination points. Lift panel
Fire Fighting Pump Panel: Main Power panel of compartmentalized, powder coated cubical panel board, free standing type, suitable for 3 Phase, 415 volts, 50 Hz, AC Supply, fabricated with CRCA sheet steel not less than 2 mm thick, dust and vermin proof, with ventilation louvers, cable alleys, detachable gland plate, ISMC 75 Channel Iron base frame, with following capacity, insulated Aluminium busbar, Incoming and out going switch gears, meters, connection, interconnection, earthing etc. complete as reqd. INCOMING Incomer : 1 Set. 630A, 4Pole, MCCB to having single frame size and common accessories, 50kA (Ics), 415V, Microprocessor release for over current, earth fault & short circuit protection, with rotary operating handle mechanism front drive kit, Spreader terminals and communication module for Ethernet (Modbus TCP/IP) provision to compatibility with IBMS and all other accessories as required. (provide extended busbar for cable termination) ii) Digital multifunction meter class 1.0 accuracy, with Rs 485 port output for IBMS integration with read (V,A,F,PF, kW, kVA, kVAR, kWh, kVAh, kVARh) etc. with - 1No. iii) 630A/5A CL.1 accuracy, 15VA metering CT - 3 Nos. iv) Protection CT 630A/5A CL. 5P10 accuracy, 15VA Protection CT -3 Nos. v) IDMT Over current, Earth fault relay, Under voltage, Over voltage relay with instantaneous element - 1Set. vi) 'RYB' and 'ON','OFF','TRIP' indication lamps connected with suitable control fuse and MCB - 1 Set. vii) Shunt trip coil 220V AC power rating - 1 No. BUSBAR Busbar in separate chamber with sealing arrangements with the following busbars 800A Capacity PH: 3Runs x 100 x10mm, NE: 1Run x100 x10mm Aluminium bus bars (vertical and horizontal) with suitable SMC supports.
AC VRF POWER PANEL: (OUT DOOR TYPE)AC Power panel of compartmentalized, Outdoor type powder coated cubical panel board, free standing type, suitable for 3 Phase, 415 volts, 50 Hz, AC Supply, fabricated with CRCA sheet steel not less than 2 mm thick, IP65 outdoor type, cable alleys, detachable gland plate, suitable size Iron base frame, with following capacity, insulated Aluminium busbar, Incoming and out going switch gears, interconnection, earthing etc. complete as reqd. INCOMING Incomer : 1 Set. 630A, 4Pole, MCCB to having single frame size and common accessories, 50kA (Ics), 415V, Microprocessor release for over current, earth fault & short circuit protection, with rotary operating handle mechanism front drive kit, Spreader terminals and communication module for Ethernet (Modbus TCP/IP) provision to compatibility with IBMS and all other accessories as required. (provide extended busbar for cable termination) ii) Digital multifunction meter class 1.0 accuracy, with Rs 485 port output for IBMS integration with read (V,A,F,PF, kW, kVA, kVAR, kWh, kVAh, kVARh) etc. with - 1No. iii) 630A/5A CL.1 accuracy, 15VA metering CT - 3 Nos. iv) Protection CT 630A/5A CL. 5P10 accuracy, 15VA Protection CT -3 Nos. v) IDMT Over current, Earth fault relay, Under voltage, Over voltage relay with instantaneous element - 1Set.vi) 'RYB' and 'ON','OFF','TRIP' indication lamps connected with suitable control fuse and MCB - 1 Set. vii) Shunt trip coil 220V AC power rating - 1 No. BUSBAR Busbar in separate chamber with sealing arrangements with the following busbars 800A Capacity PH: 3Runsx100x10mm, NE: 1Runx100x10mm Aluminium bus bars (vertical and horizontal) with suitable SMC supports.
OUTGOINGS:- 12 Sets. 125A, 415V, 50 Hz, 4P MCCB, 25 KA, Thermal magnetic based OL & SC relay and with Front drive kit.3 Sets. 63A, 415V, 50 Hz, 4P MCCB, 25 KA, Thermal magnetic based OL & SC relay and with Front drive kit. All Out going shall have i) Digital multifunction meter class 1.0 accuracy, with Rs 485 port output for IBMS integration with read (V,A,F,PF, kW,) etc. with - 1No. ii) 125A/5A CL.1 accuracy, 15VA metering CT - 3 Nos. iii) 63A/5A CL.1 accuracy, 15VA metering CT - 3 Nos. iv) 'ON','OFF','TRIP' indication lamps connected with suitable control fuse and MCB - 1 Set. EARTH Copper Earth strip of size 2Runs x 25 x 3 mm for full width of board with 2 termination points. AC VRF Outdoor power panel
UPS Panel: Main Power panel of compartmentalized, powder coated cubical panel board, free standing type, suitable for 3 Phase, 415 volts, 50 Hz, AC Supply, fabricated with CRCA sheet steel not less than 2 mm thick, dust and vermin proof, with ventilation louvers, cable alleys, detachable gland plate, ISMC 75 Channel Iron base frame, with following capacity, insulated Aluminium busbar, Incoming and out going switch gears, meters, connection, interconnection, earthing etc. complete as reqd. INCOMING Incomer 160A, 415V, 50 Hz, 4 Pole MCCB, 36 KA (Ics =100% Icu) (Micro processor based Thermal magnetic OL / SC Adjustable protection) with mechanical interlock and with extended Front drive kit and space provision to terminate 4C x 50 sq.mm AYFY UG cable.Instrument panel for Incomer - RYB LED lamps, and ON/OFF indication lamp with associated MCB's, fuses etc.Instrument panel for Digital multi function meter suitable for measuring AC voltage, Current, KWH, KW, PF, Frequency, Harmonies etc. BUSBAR Busbar in separate chamber with sealing arrangements with the following busbars 200A Capacity PH: 3Runs x 40 x 6mm, NE: 1Run x 40 x 6mm Aluminium bus bars (vertical and horizontal) with suitable SMC supports. OUTGOINGS:- 6 Sets. 63A, 415V, 50 Hz, 4P MCCB, 25 KA, Thermal magnetic based OL & SC relay and with Front drive kit, with Digital kWH meter, and ON/OFF indication lamp with associated MCB's, fuses. All Out going shall have i) Digital multifunction meter class 1.0 accuracy, with Rs 485 port output for IBMS integration with read (V,A,F,PF, kW,) etc. with - 1No. ii) 63A/5A CL.1 accuracy, 15VA metering CT - 3 Nos. iii) 'ON','OFF','TRIP' indication lamps connected with suitable control fuse and MCB - 1 Set. EARTH Copper Earth strip of size 2Runs x 25 x 3 mm for full width of board with 2 termination points. UPS panel -1 & 2
FEEDERS: 50 kVAR FEEDER - 3 Set. 250A, Three Pole, MCCB (capacitor duty) to having single frame size and common accessories, 36kA (Ics), 415V, Thermal magnetic with adjustable thermal release for over current & short circuit protection with rotary operating handle mechanism front drive kit and all other accessories as required. -1 No. 1 No. 50 kVAR capacitor duty contactor. 1 No. 50 kVAR (Heavy duty) capacitor and 14% copper wound detuned Reactor. 1 set of ON/OFF push button. 1 Set of 'ON','OFF','TRIP' indication lamps connected with suitable control fuse and MCB. 25 kVAR FEEDER - 4 Set. 100A, Three Pole, MCCB (capacitor duty) to having single frame size and common accessories, 36kA (Ics), 415V, Thermal magnetic with adjustable thermal release for over current & short circuit protection with rotary operating handle mechanism front drive kit and all other accessories as required. -1 No. 1 No. 25 kVAR capacitor duty contactor. 1 No. 25 kVAR (Heavy duty) capacitor and 14% copper wound detuned Reactor. 1 set of ON/OFF push button. 1 Set of 'ON','OFF','TRIP' indication lamps connected with suitable control fuse and MCB. 20 kVAR FEEDER - 3 Set. 100A, Three Pole, MCCB (capacitor duty) to having single frame size and common accessories, 36kA (Ics), 415V, Thermal magnetic with adjustable thermal release for over current & short circuit protection with rotary operating handle mechanism front drive kit and all other accessories as required. -1 No. 1 No. 20 kVAR capacitor duty contactor. 1 No. 20 kVAR (Heavy duty) capacitor and 14% copper wound detuned Reactor. 1 set of ON/OFF push button. 1 Set of 'ON','OFF','TRIP' indication lamps connected with suitable control fuse and MCB.
15 kVAR FEEDER - 1 Sets. 63A, Three Pole, MCCB (capacitor duty) to having single frame size and common accessories, 36kA (Ics), 415V, Thermal magnetic with adjustable thermal release for over current & short circuit protection with rotary operating handle mechanism front drive kit and all other accessories as required. -1 No. 1 No. 15 kVAR capacitor duty contactor. 1 No. 15 kVAR (Heavy duty) capacitor and 14% copper wound detuned Reactor. 1 set of ON/OFF push button.1 Set of 'ON','OFF','TRIP' indication lamps connected with suitable control fuse and MCB. 10 kVAR FEEDER - 2 Sets. 63A, Three Pole, MCCB (capacitor duty) to having single frame size and common accessories, 36kA (Ics), 415V, Thermal magnetic with adjustable thermal release for over current & short circuit protection with rotary operating handle mechanism front drive kit and all other accessories as required. -1 No. 1 No. 10 kVAR capacitor duty contactor. 1 No. 10 kVAR (Heavy duty) capacitor and 14% copper wound detuned Reactor. 1 set of ON/OFF push button.1 Set of 'ON','OFF','TRIP' indication lamps connected with suitable control fuse and MCB.
5 kVAR FEEDER - 1 Set. 32A, Three Pole, MCCB (capacitor duty) to having single frame size and common accessories, 36kA (Ics), 415V, Thermal magnetic with adjustable thermal release for over current & short circuit protection with rotary operating handle mechanism front drive kit and all other accessories as required. -1 No. 1 No. 5 kVAR capacitor duty contactor. 1 No. 5 kVAR (Heavy duty) capacitor and 14% copper wound detuned Reactor. 1 set of ON/OFF push button. 1 Set of 'ON','OFF','TRIP' indication lamps connected with suitable control fuse and MCB. CAPACITOR UNITS: The capacitor unit shall be metalized polypropylene film with Zn / Al alloy. The capacitors shall be encapsulated in an aluminium can. The capacitor unit shall have a rated voltage of 525V and shall have a maximum over current capacity of : 1.8 In. The capacitor unit shall have a built in 3 phase over pressure protection and shall have discharge resistors ( 50V in 1min ) factory fitted and shall be tamper proof. Capacitance Tolerance -5%, +10%. Maximum permissible over voltage 1.1 x Un, 8 h every 24 h. The capacitor unit shall be of certified design confirming to IS-13340-1,2. IEC 60831-1,2. REACTORS: The de-tuning reactors shall be connected in series with each capacitor stage and shall be of iron cored type. The reactors shall have relative impedance of 14%, with a de-tuning frequency of 135 Hz. The reactors shall prevent amplification of 3rd and higher order harmonics. The reactors shall have built in thermostats to protect from overheating. The reactor insulation shall be Class “H” rated at 180oC. The reactors shall be of certified design confirming to IS 2026-6, IEC-60076 - 6. SHORT CIRCUIT AND OVERLOAD PROTECTION: Each stage of the APFC Panel shall have a suitably rated MCCB with an electronic over-current relay for short-circuit and overload protection. The electronic over-current relay shall be adjusted to trip if the RMS current of the stage exceeds the overload setting. The MCCB shall be of certified design confirming to IEC 60947-1,2 & 3.
REGULATOR: Advanced Range PF Regulator shall have 12 steps with a LCD Display, Voltage Range : 90V - 550V, 50 / 60Hz, CT Input : 1A/5A with a built in RS 485 communication port. The PF Regulator shall be of certified design confirming to IS/IEC. STAGE CONTACTOR: The electromagnetic contactors shall be rated for 660 Volts and shall be 3-pole type and shall be employed for switching 'on' and switching 'off' operations in capacitor banks. The rated voltage of control coil shall be 415V (phase-to-phase). This voltage is subject to a variation of (+) 10% and (-) 15%. The contactor shall be AC3b type. The contactor shall be of certified design confirming to IS/IEC 60947-1 & 4-1. VENTILATION FANS: Ventilating fans of required size shall be used to dissipate the heat produced by the capacitor bank components like the capacitor units, reactors, contactors, breakers etc. EARTH Copper Earth strip of size 2Runs x 25 x 3 mm for full width of board with 2 termination points.350 kVAR APFCR panel
UPS ISOLATION PANEL:Supply, Erection, testing and commissioning wall mounting Isolation panel of 160A, 415V, 50 Hz, 4 Pole MCCB, 25 KA (Ics =100% Icu) (Thermal magnetic OL / SC Adjustable protection) and with extended Front drive kit with enclosure. 1 Set. RYB LED lamps, and ON/OFF indication lamp with associated MCB's, fuses.
(60 + 20 kVA UPS - I/C & O/G - 1 ) TRANSFORMER ISOLATION PANEL: Transformer Isolation Panel of compartmentalised, powder coated cubical panel board, free standing type, suitable for 3 Phase, 415 volts, 50 Hz, AC Supply, fabricated with CRCA sheet steel not less than 2 mm thick, dust and vermin proof, with ventilation louvers, cable alleys, detachable gland plate, ISMC 75 Channel Iron base frame, with following capacity, insulated Aluminium busbar, Incoming and out going switch gears, meters, connection, interconnection, earthing etc. complete as reqd. INCOMING/OUTGOING: i) 1600A, 4Pole, electrically draw out type(EDO), Air circuit breaker (ACB),microprocessor based, Icw 50kA (1 sec), 415V, Uimp = 12kV, 100% Neutral, rating confirming to IS/IEC 60947-2. as amended up to date complete with Independent manual spring closing mechanism with Microprocessor release for over current, earth fault & short circuit protection and communication module for Ethernet (Modbus TCP/IP) provision to compatibility with IBMS and all other accessories as required. (As per SLD) Transformer Incomer shall have ii) Digital multifunction meter class 1.0 accuracy, with Rs 485 port output for IBMS integration with read (V,A,F,PF, kW, kVA, kVAR, kWh, kVAh, kVARh) etc. with - 1No. iii) 1600A/5A CL.1 accuracy, 15VA metering CT - 3 Nos. iv) Protection CT 160A/5A CL. 5P10 accuracy, 15VA Protection CT -3 Nos. v) IDMT Over current, Earth fault relay, Under voltage, Over voltage relay with instantaneous element - 1Set. vi) 'RYB' and 'ON','OFF','TRIP' indication lamps connected with suitable control fuse and MCB - 1 Set. vii) 1600A/5A CT with CL:5P10,15VA with suitable control fuse For APFCR RELAY in the capacitor panel - 1 Set. viii) Shunt trip coil 220V AC power rating - 1 No. ix) Bus duct entry flange provision on top suitable for 1600A bus duct. Transformer Isolation panel
SUB HEAD -6 : EARTHING
Supply, Installation, Testing and Commissioning of the Earth pits and Earth strip on trays/ in ground /on wall / in trench etc., as per installation standard. General Requirement of Earthing : 1) Earthing - Refer Indian standard Specification :NBC 2016 VOLUNE-2, IS 3043. with latest revision. 2) Electrode: Cast iron for Corrosive Soil. Galvanized Iron / Non-galvanized Steel for Non Corrosive soil. 3) Plate Electrode: Copper. 4) Application: a) CI or GI pipe electrode for Equipment Earthing. b) Copper / GI / CI plate or tripolar for System Earthing or UPS neutral and clean earthing. 5) Installation of pipe, plate electrode and Earthing connections shall be carried out as per details given in IS 3043 with latest revision. 6) Pipe electrodes shall have 12mm drilled holes not less than 75mm from each other up to 2mtr of length from bottom to top. 7) The chamber construction shall be made as per details given in IS 3043 (masonry enclosure not less than 300 x 300 x 300mm with CI / MS frame cover). 8) Funnel with wire mesh shall be provided on top for individual electrode for maintenance. 9) Earth Strip: All Copper flat should be brazed and all GI flats should be welded. 10) Accessories: Welding for GI / MS, Brazing for Copper, GI nut bolts for connection at Empty end / PVC sleeves for copper strips / Epoxy Insulated mounts shall be considered.
Supply, Installation, Testing and Commissioning of earth pipe electrode as per IS 3043 complete with 3 mtr long with 40mm dia 'B' class G.I. pipe including watering funnel. Including 750mm x 750mm x 3mtr long excavation and construction of 700mm x 700mm x 250 mm high brick wall chamber with cement mortar. The chamber shall be provided with 450mm x 450mm x 10mm cast iron / RCC cover with frame. The plate electrode shall be filled with alternate layer of salt and charcoal as required full depth. The Cover shall be heavy duty to suit heavy vehicle movements)
Supply, Installation, Testing and Commissioning of earth pipe electrode as per IS 3043 complete with 3 mtr long with 40mm dia 'B' class G.I. pipe and copper earth plate of size 600mm x 600mm x 3mm including watering funnel. Including 750mm x 750mm x 3mtr long excavation and construction of 850mm x 850mm x 300 mm high brick wall chamber with cement mortar. The chamber shall be provided with 450mm x 450mm x 10mm cast iron / RCC cover with frame. The plate electrode shall be filled with alternate layer of salt and charcoal as required full depth. The Cover shall be heavy duty to suit heavy vehicle movements)
Supply and run of following sizes of copper/ Alu. flat from earth electrode to neutral terminals of transformer and other required locations as per statutory requirements and neatly clamped to wall, cable tray with necessary hardware's, PVC FRLS conduits at places required as directed by Architects / Consultants.
25 x 6mm GI. Flat
40 x 6mm GI. Flat
25 x 3 mm Cu. Flat
50 x 6 mm Cu. Flat
8 SWG copper.
SUB HEAD -7 : STREET LIGHT AND FAÇADE LIGHT LUMINARIES
Supply, Installation, Testing and Commissioning of Light fixtures and lamps with all accessories, fixing on the wall / Ceiling / False ceiling with PVC blocks, screws , hardware's, suspended chain hooks as required as per the site conditions (including the earthing of fixture). General Requirement of Light Fittings: 1) LEDS - LOW POWER ONLY : 2 - MECADUM - LEVEL - with manufacturers certificate. 2) Driver : 120V to 270V 50HZ with ISI or CE Certificate. (With Surge Protector of 2.5 to 3KV. along with separate earthing stud.) 3) Lumen Maintenance Certificate: LM-80. 4) Luminar test certificate: LM-79. 6) System Lumen efficiency: >120 Lm/W. 7) Colour rendering index (CRI) : >80. 8) Colour temperature : 5700K. 9) Ballast: Electronic ballast THD shall be (THD-I) : < 10%. 10) Glare Index ≤ 19. 11) Power factor:> 0.9. 12) Uniformity shall be 70% over 95% of the area. 13) Lamp life : >24,000 Hrs. 14) WARRENTY : 3 years free replacement along with driver. 15) All Fixture shall be prewired up to terminal block with loop in-loop out facility. 16) IP Class: a) Indoor IP20, b) Outdoor IP65, 66,67, Note : The colour of the light fixture shall be as per the architect choice, Vendor to do mock-up before installing . Make - LEDS : OSRAM / PHILIPS-LUMILEDS / BRIDGLUX/ CREE / NICHIA / EPISTAR / EDISON / HEATSINK Make - Light Fixture : PANASONIC / BAJAJ /JAGUAR / PHILIPS / OSRAM / WIPRO / CROMPTON
Supply, installation, testing and commissioning of LED street light fixture with minimum lumen output of 4500 lumen and 5700K colour temperature with Pressure die-cast IP 66. The luminaire is to operate within the voltage range of 150V-270V with >0.95 PF and <10% THD. LED life of 50,000 burning hours as per L70 criteria. Surge protection up to 4kV. LED driver designed for CVCC, APFC operation with all accessories including connection with 2.5sq mm FRLS PVC insulated copper conductor, single core cable and earthing etc. as required.
Design, supply, erection and testing of GI octagon pole of 130 A/F in bottom and 70 A/F in top with 3mm thick Single Ornamental bracket. Height of Pole 6Mtrs. above ground level with necessary long bracket including providing necessary base plate fixing arrangements providing. Construction of pillar accommodating MCB and switch housed in weather proof box including wiring to the light fittings with 2 runs of 2.5 Sq.mm PVC insulated copper conductor, supplying and fixing 4 way 30 A rated terminal block loop in loop out cable arrangements coil earthing (pole earthing with 8 SWG GI wire of 75 feet length wound as a coil to have 115 turns of 75/50 mm dia as to have good contact with soil is to be provided.)etc. the rate shall included for cable in and out through pipe. The pole shall be painted with one coat of primer and two coats of enamel paint as required by the Engineer in charge and complete with suitable pressure die cast aluminium housing also adhering to the above said specifications. Note:-The rate shall be quoted for complete set of Pole, Base foundation, Anchor fastener, internal wiring, earthing materials,6A DP MCB box and all necessary accessories and civil cost etc. should be provided as suitable for 45W system wattage.
Supply, installation, testing and commissioning of the IP65 LED Bollard light fixture with minimum lumen output of 1100 lumens of Square mounting type circular LED Luminaire with Aluminium housing 6500K colour temperature with driver suitable for operation on single phase 230 V, 50Hz, Ac supply with all accessories including connection with 1.5sq mm FRLS PVC insulated copper conductor, single core cable and earthing etc. as required.
Supply, installation, testing and commissioning of the IP66 LED Flood light fixture with minimum lumen output of 35000 lumens of Rectangular type LED Luminaire with Aluminium die-cast housing and toughened glass and unique lens with 5700K colour temperature with driver suitable for operation on single phase 230 V, 50Hz, Ac supply with all accessories including connection with 1.5sq mm FRLS PVC insulated copper conductor, single core cable and earthing etc. as required.
Supply, installation, testing and commissioning of the IP65 LED Spike light fixture with minimum lumen output of 1200 lumens of Square mounting type circular LED Luminaire with Aluminium housing 4000K colour temperature with driver suitable for operation on single phase 230 V, 50Hz, Ac supply with all accessories including connection with 1.5sq mm FRLS PVC insulated copper conductor, single core cable and earthing etc. as required.
SUB HEAD -8 : DG SET & EXHAUST SYSTEM
Make - DG SET : KIRLOSKAR / POWERICA - CUMMINS 910 kVA DG Set.
Supply, Installing, Testing and Commissioning of 'Silent Type' Diesel Generating set having Prime Power Rating of 910 KVA at 1500 RPM, 0.8 lagging power factor at 415 Volts suitable for 50 HZ, 3 phase system, for 0.85 Load factor and Noise level as per CPCB guide line and consisting of the followings: a) Diesel Engine: Diesel engine 4 stroke water cooled, electric start, of suitable BHP at 1500 RPM suitable for above output of alternator at NTP and conforming to BS 5514, BS 649, ECBC, IS 10000, capable of taking 10% over loading for one hour after 12 hours of continuous operation. The engine will be fitted complete with all the required accessories. b) Engine mounted Instrument Panel fitted with and having digital / analog display for following: i) Start-stop switch with key. ii) Water temperature indication iii) Lubrication oil pressure indication iv) Battery charging indication v) RPM indication vi) Over speed indication vii) Low lube. Oil trip indication viii) Engine Hours indication c)Alternator: Synchronous alternator rated at 910 KVA, 415 volts at 1500 RPM, 3 Phase 50 HZ, AC supply with 0.8 lagging power factor at NTP. The alternator shall be having SPDP enclosure, brushless, continuous duty, self-excited and self-regulated through AVR conforming to ECBC, IS: 4722/BS 2613 suitable for tropical conditions and with class F/ H insulation. d)Base Frame. Both the engine and alternator shall be mounted on suitable base frame made of MS channel with necessary reinforcement which shall be installed on existing cement concrete foundation and vibration isolation arrangement as per recommendations of manufacturer.
e) Fuel Tank: Inbuilt Fuel tank of suitable capacity complete with valves, level indicator i/c suitable fuel hoses / fuel piping & accessories etc., as required. f)Exhaust System: Dry exhaust manifold with suitable residential exhaust silencer to reduce the noise level. g)Starting System: 12V/24V DC Starting system comprising of starter motors, voltage regulator and arrangement for initial excitation complete with suitable nos. of batteries (25 plates, 180 Amp. Hour capacity lead acid type) as required as per specifications & manufacturers standard. h) Acoustic enclosure Acoustic and weather proof enclosure with arrangement for fresh air intake for cooling of the engine & alternator, extraction & discharging hot air in to the atmosphere etc. as per specifications to accommodate item (a) to (g).
EXHAUST SYSTEM: 910kVA DG Set.
Supply and Erection of 14'' Dia. MS class "B" pipe with 5mm Thick.
Supply and Erection of 50 mm Thick thermal insulation with aluminium cladding for exhaust pipe.
Supply and Erection of 50 mm Thick insulation with aluminium cladding for Silencer.
SUB HEAD -9 : LIGHTNING
Spike - Five Pronged Lighting Spike Fixed on Gun Metal Ball Mounted on 19mm Dia Copper Tube 1mtrs. Long with Gun Metal 150mm Dia base with all accessories for fixing of the down Conductors.
Down Conductor - 25x3 mm Copper Flat Running along with column and fixed with suitable GI clamp with 10mm thick hylam spacer at every 500mm interval.
SUB HEAD -10 : SAFETY ITEMS
Supply and installation of 440KV Danger board as required by the Electrical authorities of size 500mm x 300mm of 16 SWG MS of the Substation / Electrical room. The lettering shall be as per TANGDCO standards.
Supply and laying of chequered rubber mat with ISI mark suitable for 440V installation as per IS 15652 - class - 2000 x 1000 x 6 mm thick.
Supply of 4 nos. 10 litres round bottomed fire bucket with floor mounting stand - ISI Standard
Supply and fixing of Safety/ shock treatment chart
Supply and fixing of First aid Kit
Supply of tested hand gloves of 415V grade as per IS standards
Supply and fixing of HT / LT cable route indicator made out of MS flat and angle iron.
Make - Lift : JOHNSON / KONE / OTIS 20 PASSENGER LIFT
SUB HEAD -1 : ROOF TOP SOLAR POWER PLANT ON-GRID SYSTEM:
The price includes supply and install hot galvanised steel for vertical supports, plates & screws, profiles for steel skeleton including bracing and double hot galvanized angles for dividers. according to the Site condition, price shall include costs of repairing any damaged works. The contractor should provide manufacturer's warrantee for each solar panel for a period not less than 20 years with all necessary DC and AC electrical cables (UV Protected), Surge Protection devices, earthing, Conduits and trays and all other materials and workmanship needed to connect with the distribution panel according to the to site conditions and CEIG approval and have a complete job . FINAL DOCUMENT: Including CEIG Approval and safety Certificate. Preparation of Shop Drawings, as-built drawings, operation and Maintainers manuals. Make - Solar Inverter : ABB / SOLAR EDGE/ SMA Make - Solar panel : RENUSIS / ADANI / AXITECH Make - Solar DC Cable : SIECHAM / LAP/ LEONI Make - Solar AC Cable : HAVELLS / RR KABLE Designing, Supply, Installation, Testing and Commissioning of on grid roof top Solar Photovoltaic Power Plant conforming to MNRE specifications as amended, consisting of Poly Crystalline / Mono Crystalline silicon solar cells, net metering facility, necessary protections, earthing, mounted on GI structure and CC foundation for the GI structure of suitable strength with components complete as required. SOLAR PV PANEL: Solar Photovoltaic Module of capacity 330Wp or above, manufactured in India, conforming to IS14286 / IEC61215, IS/IEC 61730 - Part-1, IS/IEC 61730 - Part-2. Solar Photo voltaic Module conversion efficiency shall not be less than16.5%.PV modules used in solar power plants/ systems must be warranted for their output peak watt capacity, which should not be less than 90% attend of 10 years and 80% at the end of 25 years. including proper CC foundation, structure, painting etc... complete as required
SOLAR INVERTER: Inverter of 350 - 800VDC Input voltage range and 400VAC, three phase, 4wire, 50Hz, out put voltage suitable to generate AC Power with efficiency not less than 97%,total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 degree C. The Inverter shall adjust the voltage and frequency level to suit the Grid Voltage Frequency. Data Monitoring System complete with accessories including RS485 communication port to integrate with the BMS. Fixing of Array junction box & Main junction box with IP65 protection and termination arrangement for incoming and outgoing cable along with glands, lugs and other accessories etc. as required. Lightning and surge voltage protection. Connections & Inter connections by supplying & fixing required size XLPE insulated copper conductor 1.1kV grade armoured power and control cables between solar modules, main power cable to grid supply (up to main electrical panel switchgear and terminations) and Inverter unit along with supplying & fixing of necessary channel/conduit lugs and other accessories etc. as required. Solar cable shall be Flexible Tinned Copper Conductor Single Core (2 Runs for +ve and -ve) Multistrand, Cross Linked, Zero Halogen Low Smoke Insulation and Cross Linked Low Smoke Sheathing ,Heat Resistant up to 120⁰C and UV Resistant Solar Cables between solar modules Array junction box and PCD unit including lugs ,other accessories and 6 SWG dia G.I. wire for earthing of all solar panel boards, structure and up to PCU Plant shall have suitable inverter, array junction box, lighting and surge protection and all other accessories etc. provisions as required. 35kW solar net metering system.
Description of Work / Item(s)
Amount
IMPORTANT GENERAL NOTES: 1.Rate shall Including CEIG, TANGEDCO Approval and safety Certificate for all the External and internal electrical works and electrical equipment's.
SUB HEAD -1 : DISTRIBUTION BOARD
Supply, Installation, Testing and Commissioning of MCB Distribution board as per approved installation drawings either concealed / surface mounted with required accessories as per site condition. General Requirement of Distribution Board : 1) DB- Refer Indian standard Specification : IS/IEC 61439-3 with latest revision. 2) Enclosure:1.2mm CRCA Sheet Steel, Powder Coated. 3) DB type: Horizontal - 7 Segment, SPN and ETPN. Vertical - VTPN MCCB / MCB for UPS DB's, Lighting, Emergency Lighting & Raw power. 4) Door : Double Door. 5) Protection : IP 43. 6) Cable Entry : Top & Bottom. 7) UPS distribution RCCB's shall be harmonic resistant (SI Series).
8) Bus bar : Shall be tinned Copper and 100% rating for UPS DB Neutral Link. 9) MCB's : 10kA rupturing capacity 'C' Curve for Lighting & Raw power, 10kA rupturing capacity 'D' Curve for UPS Distribution. 10) Separate Earth bus/Neutral bus for each phase. 11) Each Circuit shall have yellow ferrules with circuit number details. 12) Accessories required for installation of DB's on Wall / Column / Gyp Board shall be considered. 13) DB's shall be covered with powder coated (paint should match with DB Colour) wire ways all around and up to ceiling to receive incoming circuits, how ever raceway shall be considered as a separate items & same shall be paid under raceway item. 14) Safe shroud for Neutral link shall be provided. 15) All MCB's & Isolators should have provision for LOTO using Padlocks. 16) Laminated A3 (OR) A4 size SLD & Control drawing copy shall be pasted inside DB door. 17) Marking legibly with Paint. 18) Body Earthing (Copper wire / 8SWG copper) to be done.
Supply, fixing, testing and commissioning of 16Way, SPN , Double Door, MCB DB comprising of the following: 16 Way SPN DB I/C: 40A DP MCB - 1 No. O/G: 25A DP MCB ('D' Curve) -7 Nos. (MAIN COMM. - ELDB)
Supply, fixing, testing and commissioning of 16Way, SPN , Double Door, MCB DB comprising of the following: 12 Way SPN DB I/C: 25A DP Hi 30mA RCCB - 1 No. O/G: 10A SP MCB ('D' Curve) -10 Nos. (ELDB)
Supply, fixing, testing and commissioning of 16Way, SPN , Double Door, MCB DB comprising of the following: 8 Way 7Seg. DB I/C:40A 4P MCB ('C' Curve) - 1 No. : 3P+NPE TYPE -II SPD. SUB I/C: 25A DP RCCB (30mA) - 3 Nos. O/G: 6A SP MCB ('C' Curve) -24 Nos. (LDB)
Supply, fixing, testing and commissioning of 8 Way, 7 Seg, Double Door, MCB DB comprising of the following : 8 Way 7Seg. DB I/C:40A 4P MCB ('C' Curve) - 1 No. : 3P+NPE TYPE -II SPD. SUB I/C: 25A DP RCCB (30mA) - 3 Nos. : Digital time switch with Astronomical Function - 3 Nos O/G: 10A SP MCB ('C' Curve) -24 Nos. (Ext-LDB)
Supply, fixing, testing and commissioning of 8 Way, 7 Seg, Double Door, MCB DB comprising of the following : 8 Way 7Seg. DB I/C:63A 4P MCB ('C' Curve)- 1 No. : 3P+NPE TYPE -II SPD. SUB I/C: 40A DP RCCO (30mA) - 3 Nos. O/G: 16A SP MCB ('C' Curve) -24 Nos. (PDB)
Supply, fixing, testing and commissioning of 8 Way, 7 Seg, Double Door, MCB DB comprising of the following : 8 Way 7Seg. DB I/C:63A 4P MCB ('C' Curve)- 1 No. : 3P+NPE TYPE -II SPD. SUB I/C: 40A DP RCCO (30mA) - 3 Nos. O/G: 16A SP MCB ('C' Curve) -24 Nos. (PDB-VRF/ID)
Supply, fixing, testing and commissioning of 12 Way, 7 Seg, Double Door, MCB DB comprising of the following : 12 Way 7Seg. DB I/C:63A 4P MCB ('C' Curve)- 1 No. : 3P+NPE TYPE -II SPD. SUB I/C: 40A DP RCCO (30mA) - 3 Nos. O/G: 16A SP MCB ('C' Curve) -36 Nos. (PDB)
Supply, fixing, testing and commissioning of 4 Way, 7 Seg, Double Door, MCB DB comprising of the following : 4 Way 7Seg. DB I/C:63A 4P MCB ('D' Curve)- 1 No. : 3P+NPE TYPE -II SPD. SUB I/C: 40A DP RCCB Hi (30mA) - 3 Nos. O/G: 16A SP MCB ('D' Curve) -12 Nos. (UPSDB)
Supply, fixing, testing and commissioning of 8 Way, 7 Seg, Double Door, MCB DB comprising of the following : 8 Way 7Seg. DB I/C:40A 4P MCB ('D' Curve)- 1 No. : 3P+NPE TYPE -II SPD. SUB I/C: 40A DP RCCB Hi (30mA) - 3 Nos. O/G: 16A SP MCB ('D' Curve) -24 Nos. (UPSDB)
Supply, fixing, testing and commissioning of 12 Way, SPN, Double Door, MCB DB comprising of the following : 12 Way SPN DB I/C:63A 4P MCCB - 1 No. O/G: 40A 4P RCCB(300mA) - 1 No. 16A SP MCB ('C' Curve) - 3 Nos. (LIFT DB)
Supply, fixing, testing and commissioning of 4 Way, VTPN, Double door, MCB DB comprising of the following 4 Way VTPN DB I/C:63A 4P MCB ('C' Curve)- 1 No. : 3P+NPE TYPE -II SPD. O/G : 40A, TP, MCB -1 Nos. : 32A, TP, MCB - 1 Nos. : 25A, SP, MCB - 6 Nos. (AUX -PDB)
Supply, fixing, testing and commissioning of MS enclosure with 63A 4P RCCB (300mA) and other associated accessories as required. (VRV O/D)
Supply, fixing, testing and commissioning of MS enclosure with 100A 4P MCCB and other associated accessories as required. (UPS)
Supply, fixing, testing and commissioning of MS enclosure with 32A 4P MCB and other associated accessories as required. (Utility)
SUB HEAD -2 : WIRING
Supply and wiring for the following Light, Exhaust Fan, 6A independent socket outlets points, using multi-strand copper wires drawn through suitable dia concealed MS conduit with all necessary conduit accessories such as junction boxes bends, couplings etc. The specified conduit shall be laid in roof slab requirement of site condition. The rate shall include embedding pipes, accessories etc., in wall / ceiling including necessary chasing on wall making the surface good etc. General Requirement of Wiring and FRLS PVC Conduit : 1) Wiring as per IS 732, NBC 2016 Volume-2 with latest revision. 2) Voltage Grade : 660 / 1100V. 3) Conductor : Multistrand Copper. 4) Insulation: FRLS PVC. 5) Outer sheath: FRLS PVC only for multicore cable. 6) There shall not be any joints except at the equipment end. 7) Individual UPS and Raw power points shall have yellow ferrules for circuit identification. 8) No different phases shall be drawn in same conduit. 9) The number of wires drawn in each conduit shall be as per IS 694 code with latest revision. 10) Lighting Circuit : Limited to 800W or 10 points which ever is less. The circuit wiring should be independent of point wiring. (The point wiring length may be considered 8 Mtrs. Length approx..).
General Requirement of MS Conduit : 1) MS Conduits as per IS 3419, IS 9537, IS 14768-2, IS 3480, 3837 with latest revision, concealed at ceiling / laying in above false ceiling in multiples shall be supported by Slotted GI 'C' channel at distance not more than 0.5mtrs intervals. OR else with spacers & saddles at an intervals of 0.5mtrs. 2) Gauge:16 SWG up to 32mm Dia & 14G SWG above 32mm Dia. 3) Material: MS with anticorrosive paint with threading on both the ends. 4) Accessories: MS with Threaded type - accessories shall includes Bends, Collars, junction boxes, Spacers, saddles, screws, Flexibles. 5) MS Conduits shall be heavy duty & ISI marked. 6) MS conduit of thickness not less than 2mm conform to I.S with all necessary conduit accessories. 7) No different phases shall be drawn in same conduit. 8) MS conduit joints shall be done with threading proper accessories only. Note : The colour of the conduit shall be as per the Engineering Consultant choice, Vendor to do mock-up before installing the conduits.
Light Point Wiring:
Supply, Erection, Testing and commissioning of 3R 1.5sqmm PVC insulated FRLS copper wire in FRLS PVC conduit along with Modular 2 Way 6A switch and moulded front plate GI anodized enclosure and other associated accessories as required as per the site conditions. Light point (2 way control) (Ave. 8Mtr)
Supply, Erection, Testing and commissioning of 3R 1.5sqmm FRLS copper wire in MS conduit along with Modular 6A switch and moulded front plate GI anodized enclosure and other associated accessories as required as per the site conditions.
Primary point (Ave. 8Mtr)
Secondary point (Ave 4Mtr - with out switch)
Exhaust Fan point (Ave. 8Mtr)
Fan point (Ave. 8Mtr)
Supply, Erection, Testing and commissioning of 2R 1.5 sqmm + 1R 1.5 sqmm FRLS copper wire in 25mm dia MS conduit and fixing the conduit with clamps at different intervals with all accessories as required as per site conditions. (For Emergency light wiring)
Supply, Erection, Testing and commissioning of 2R 2.5sqmm + 1R 2.5 sqmm FRLS copper wire in 25mm dia MS conduit and fixing the conduit with clamps at different intervals with all accessories as required as per site conditions. (For lighting circuit wiring)
Power Wiring:
Supply, Erection, Testing and commissioning of 2R 2.5sqmm + 1R 2.5 sqmm FRLS copper wire in 25mm dia MS conduit and fixing the conduit with clamps at different intervals with all accessories as required as per site conditions. (For raw power, VRV I/D, and work station)
Supply, Erection, Testing and commissioning of 3C x 2.5sqmm FRLS copper flexible cable in existing Race way with all accessories as required as per site conditions. (For raw power and work station)
Supply, Erection, Testing and commissioning of 3C x 2.5sqmm FRLS copper flexible cable in existing Race way with all accessories as required as per site conditions.(For UPS power circuit)
Supply, Erection, Testing and commissioning of 2R 4 Sq. mm + 1R 2.5 Sqmm FRLS copper wire in 25mm dia MS conduit and fixing the conduit with clamps at different intervals with all accessories as required as per site conditions. (For Raw Power & UPS power circuit)
Supply, Erection, Testing and commissioning of 2R 6 Sq. mm + 1R 4 Sqmm FRLS copper wire in 25mm dia MS conduit and fixing the conduit with clamps at different intervals with all accessories as required as per site conditions. (Sub main wiring UPS and common LDB)
SUB HEAD -3 : SWITCH, SOCKET AND GI RACE WAY
Supply, Installation, Testing and Commissioning of the Modular switch/ Socket / receptacles mounted in suitable size with modular front plate and suitable Phosphated MS / PVC back box accessories as per the site conditions. General Requirement of Switch & Socket and GI Back box : 1) The Modular switch/ Socket / receptacles mounted in suitable size Phosphated MS switch box front plate etc. required to complete the point wiring in full as per IS 732 with latest revision. 2) Refer Standard: IS 11037, IS 3854, IS 1293 with latest revision. 3) Terminal : Phosphor bronze. 4) Enclosure for Current carrying part; Thermoplastic/ABS plastic complying to environment recycling. 5) Front plate : Thermoplastic / Polycarbonate complying to environmental recycling. 6) IP Class for Modular sockets: IP20. 7) Safety shutters to prevent accidental contact with live parts shall be provided. 8) GI back box of thickness not less than 1.8 mm. Note : The colour of the switch & socket shall be as per the architect, Consultant choice, Vendor to do mock-up before installing .
Supply, Installation, testing and commissioning of 2Nos. 6/10/13A multistandard socket control by 1No. 16A switch with suitable PVC front plate and back box with all accessories as required as per site conditions. (UPS power for Work Station)
Supply, Installation, testing and commissioning of 3Nos. 6/10/13A multistandard socket controlled by 1No. 16A switch with suitable PVC front plate and back box with all accessories as required as per site conditions. (UPS power for workstation)
Supply, Installation, testing and commissioning of 1No. 6/10/13A multistandard socket control by 1No. 6A switch with suitable PVC front plate and back box with all accessories as required as per site conditions. (Raw power for Workstation, TV, Display unit)
Supply, Installation, testing and commissioning of 1No. 6A 5pin socket control by 1No. 6A switch with suitable PVC front plate and back box with all accessories as required as per site conditions. (Raw power for Utility)
Supply, Installation, testing and commissioning of 1No. 6/16A socket control by 1No. 16A switch with suitable metal box and front plate with all accessories as required as per site conditions. (Raw power for printer)
Supply, Installation, testing and commissioning of 1No. 6/16A socket control by 1No. 16A switch with indicator and suitable metal box and front plate with all accessories as required as per site conditions. (For Utility Socket)
Supply, Installation, testing and commissioning of 1No. 6/16A socket control by 1No. Independent 16A switch with indicator and suitable metal box and front plate with all accessories as required as per site conditions. (For projector)
Supply, Installation, testing and commissioning of 1Nos. 6A socket control by 1No. 6A switch and 1No 6A switch for controlling bulkhead fitting with suitable PVC back box and front plate with all accessories as required as per site conditions. (For Lift shaft).
Supply, Installation, testing and commissioning of DAYLIGHT sensor with all accessories as required as per site conditions.
Supply, Installation, testing and commissioning of occupancy sensor with all accessories as required as per site conditions.
Supply and fixing for GI Floor trunking of the following sizes with all necessary accessories such as joints, bends, couplings etc.
100mm X 38mm -1 compartments GI Raceway.
100mm X 38mm Metal Fixing bracket.
Riser - 225mm
38mm coupling - Coupler for joining raceway
150mm X 150mm - Floor junction box with cover
225mm X 225mm - Floor junction box with cover.
SUB HEAD -4 : LT CABLE & TERMINATION
Supply and laying of following sizes of 1.1kv grade EBXL / XLPE insulated armoured FRLS grade cable with aluminium / copper conductor multistrand cable with ISI markings of approved make and quality from electrical panel to various switch boards / distribution boards . the cable shall be laid in the cable trays, racks (excluding supply & erection of cable trays / racks) wherever cable are required to be laid on wall, base bracket fitted onto wall / ceiling and necessary clamps/ hardware's etc. all complete and the rate for such clamps, hardware's shall be included in the scope. before laying the cable approval for the routing and the manner of laying shall be obtained from the architect / client. General Requirement of LT Cable & Termination : 1) Power & control cables - Refer Indian standard Specification : IS 1554, IS 7098, IS 5831, IS 3975, IS 694, with latest revision. 2) Installation: Refer Standard IS1255 with latest revision. 3) Core : Multicore / Single core Armoured / Un -armoured cable. 4) Insulation: XLPE above 25Sqmm and Class A PVC below 25Sqmm. 5) Inner sheath: Extruded PVC only for Multicore. 6) Outer sheath: Extruded Type ST2 PVC. 7) PVC Cable shall be a tough outer sheathing of PVC FRLS insulating material in standard colours. 8) Voltage grade:1100Volts. 9) Armoured: Galvanized Steel strip/Wire for multicore Non Magnetic Aluminium Wire/Strip for Single core. 10) Conductor: Aluminium / Copper conductor multistrand. 11) Cable shall be ISI marked and EBXL / XLPE insulated Make Cable: Seichem / RR Kable / Havells / Polycab Make Cable Termination : 1) Gland - Double compression Comet / Siemens / Dowells. 2) Lugs - Comet / Dowells / Hex.
4C x 400 Sq. mm Al. Ar. XLPE Cable.
4C x 300 Sq. mm Al. Ar. XLPE Cable.
4C x 185 Sq. mm Al. Ar. XLPE Cable.
4C x 120 Sq. mm Al. Ar. XLPE Cable.
4C x 50 Sq. mm Al. Ar. XLPE Cable.
4C x 16 Sq. mm Al. Ar. XLPE Cable.
4C x 10 Sq. mm Al. Ar. XLPE Cable.
4C x 16 Sq. mm Cu. Ar. XLPE Cable.
4C x 10 Sq. mm Cu. Ar. XLPE Cable.
4C x 2.5 Sq. mm Cu. Ar. XLPE Cable.
3C x 2.5 Sq. mm Cu. Ar. XLPE Cable.
12C x 2.5Sq mm Cu. Ar. XLPE Cable.
Supply and providing cable end termination for following sizes of 1100V grade EBXL/XLPE insulated armoured FRLS grade Aluminium / Copper conductor multi-strand cable with necessary gland sand jointing materials etc. all as per requirement.
4C x 400 Sq. mm Al. Ar. XLPE Cable.
4C x 300 Sq. mm Al. Ar. XLPE Cable.
4C x 185 Sq. mm Al. Ar. XLPE Cable.
4C x 120 Sq. mm Al. Ar. XLPE Cable.
4C x 50 Sq. mm Al. Ar. XLPE Cable.
4C x 16 Sq. mm Al. Ar. XLPE Cable.
4C x 10 Sq. mm Al. Ar. XLPE Cable.
4C x 16 Sq. mm Cu. Ar. XLPE Cable.
4C x 10 Sq. mm Cu. Ar. XLPE Cable.
4C x 2.5 Sq. mm Cu. Ar. XLPE Cable.
3C x 2.5 Sq. mm Cu. Ar. XLPE Cable.
12C x 2.5Sq mm Cu. Ar. XLPE Cable.
SUB HEAD -5 :CABLE TRAY
Supply and Installation of the following sizes of Cable trays suspended from the ceiling or Along the wall or in trench or on floor, with accessories as required by the site condition. General Requirement of Cable tray & Wire ways : 1) Cable tray - Refer Indian standard Specification : IS/IEC 61537, EN 10346 with latest revision. 2) Material : MS. 3) Finish : Pre Galvanized for indoor & Hot dip galvanized for Outdoor (NA). 4) Thickness : 2.5 mm. 5) Type: Ladder or Perforated / Solid. 6) Rung Spacing : 300mm. 7) Rung width : 35mm. 8) Supports: Up to 300mm wide using Hi-tech Rod and above 300mm wide using MS angle supports with anticorrosive paint at an intervals of 500mm. 9) Accessories: Couplers, Bends, Reducers, Tees & Cross junctions shall be considered. 10) The trays installed on floor shall be mounted on 'C' clamp with accessories. 11) Installation: Ladder type (above 300 mm) / up to 300 perforated type cable trays including Tees, Bends etc. Make Cable Tray : OBO-Bettermann / ProFab. Make - Cable Tray support & cable Clamping accessories : OBO-Bettermann / ProFab. Supply and fixing of Cable Ladder with horizontal & vertical bends, reducers, Tee's, Cross over, supports, brackets and other accessories as required confirming to IS/IEC-61537.The Cable Ladder shall be made of 1.5mm thick sheet steel up to 600mm.The cable Ladder shall be 275 GSM strip galvanized sheet steel for corrosion protection confirming to DIN EN 10346 .The cable ladder should be tested for safe working load of 140 Kg/ Mtr with a span distance of 2 Mtr the deflection should be within the limits as per standard. The cable ladder shall be supplied in standard length of 3000 mm. The rung size shall be of 30x15mmm size suitable for fixing the cable clamps the space between the rungs shall be 300mm.
250 mm width x 50 mm depth
300 mm width x 50 mm depth
450 mm width x 50 mm depth
750 mm width x 75 mm depth
Design, Fabricating, Supply and Installing varies type MS supports for cable tray to suit to withstand the weight of the number of cables to be laid as per the site requirement. The Supports of cable trays shall be fabricating out of 25mm x 25mm x6mm angle iron with necessary welded cross supports of size 25mm x 6mm MS flat (or) 10mm threaded rod with tray support from roof as may be required. The rate shall be include all supporting brackets, Anchor Fasteners including 2 coats of zinc rich primer and 2 coats of enamel epoxy painting of cable trays support.
Cable identification tags made out of round aluminium plates of thickness not less than 3mm and tying with cable with appropriate intervals for cable emanating from individual SSB. The work should be carried out as required by Inspecting Authorities as well as satisfaction of Consultant.
SUB HEAD -6 : LUMINARIES
Supply, Installation, Testing and Commissioning of Light fixtures and lamps with all accessories, fixing on the wall / Ceiling / False ceiling with PVC blocks, screws , hardware's, suspended chain hooks as required as per the site conditions (including the earthing of fixture). General Requirement of Light Fittings: 1) LEDS-LOW POWER ONLY: 2-MECADUM-LEVEL- with manufacturers certificate. 2) Driver : 120V to 270V 50HZ with ISI or CE Certificate. (With Surge Protector of 2.5 to 3KV. along with separate earthing stud.) 3) Lumen Maintenance Certificate: LM-80. 4) Luminar test certificate: LM-79. 6) System Lumen efficiency: >100 Lm/W. 7) Colour rendering index (CRI) : >80. 8) Colour temperature : 5700K. 9) Ballast: Electronic ballast THD shall be (THD-I) : < 10%. 10) Glare Index ≤ 19. 11) Power factor:> 0.9. 12) Uniformity shall be 70% over 95% of the area. (350 lux @ 750mm level from FFL ) 13) Lamp life : >24,000 Hrs. 14) WARRENTY : 3 years free replacement along with driver. 15) All Fixture shall be prewired up to terminal block with loop in-loop out facility. 16) IP Class: a) Indoor IP20, b) Outdoor IP65, Note : The colour of the light fixture shall be as per the architect choice, Vendor to do mock-up before installing . Make - LEDS : OSRAM / PHILIPS-LUMILEDS / BRIDGLUX/ CREE / NICHIA / EPISTAR / EDISON / HEATSINK Make - Light Fixture : PANASONIC / BAJAJ /JAGUAR / PHILIPS / OSRAM / WIPRO / CROMPTON
Supply, installation, testing and commissioning of LED tube light fixture with minimum lumen output of 4000 lumen and 6000K colour temperature with driver suitable for operation on single phase 230V, 50Hz, AC supply with all accessories including, frame, diffuser, driver, interconnecting wires, earthing and fixing hardware's etc. as required.
Supply, installation, testing and commissioning of the LED Bulkhead light fixture with minimum lumen output of 1000 lumens of Square mounting type circular LED Luminaire with Aluminium housing and opal diffuser 6000K colour temperature with driver suitable for operation on single phase 230 V, 50Hz, Ac supply with all accessories including connection with 1.5sq mm FRLS PVC insulated copper conductor, single core cable and earthing etc. as required.
Supply, installation, testing and commissioning of the LED light fixture with minimum lumen output of 1200 lumens of recessed mounting type circular LED Luminaire with Aluminium housing and opal diffuser 6000K colour temperature with driver suitable for operation on single phase 230 V, 50Hz, Ac supply with all accessories including connection with 1.5sq mm FRLS PVC insulated copper conductor, single core cable and earthing etc. as required.
Supply, installation, testing and commissioning of the LED light fixture with minimum lumen output of 2400 lumens of surface mounting type circular LED Luminaire with Aluminium housing and opal diffuser 6000K colour temperature with driver suitable for operation on single phase 230 V, 50Hz, Ac supply with all accessories including connection with 1.5sq mm FRLS PVC insulated copper conductor, single core cable and earthing etc. as required.
Supply, installation, testing and commissioning of the LED light fixture with minimum lumen output of 2400 lumens of Recess mounting type circular LED Luminaire with Aluminium housing and opal diffuser 6000K colour temperature with driver suitable for operation on single phase 230 V, 50Hz, Ac supply with all accessories including connection with 1.5sq mm FRLS PVC insulated copper conductor, single core cable and earthing etc. as required.
Supply, installation, testing and commissioning of the LED light fixture with minimum lumen output of 600 lumens of Recess mounting type circular LED Luminaire with Aluminium housing and opal diffuser 6000K colour temperature with driver suitable for operation on single phase 230 V, 50Hz, Ac supply with all accessories including connection with 1.5sq mm FRLS PVC insulated copper conductor, single core cable and earthing etc. as required.
Supply, installation, testing and commissioning of Mirror LED tube light fixture with minimum lumen output of 1000 lumen and 6000K colour temperature with driver suitable for operation on single phase 230 V, 50Hz, Ac supply with all accessories including, frame, diffuser, driver, interconnecting wires, earthing and fixing hardware's etc. as required.
Supply, installation, testing and commissioning of the 2' x 2' LED light fixture with minimum lumen output of 3600 lumens of recess mounting type LED Luminaire with Aluminium housing and opal diffuser 5700K colour temperature with driver suitable for operation on single phase 230 V, 50Hz, Ac supply with all accessories including, frame, diffuser, driver, interconnecting wires, earthing and fixing hardware's etc. as required.
Supply, installation, testing and commissioning of the 2' x 2' LED light fixture with minimum lumen output of 3300 lumens of recess mounting type LED Luminaire with Aluminium housing and opal diffuser 5700K colour temperature with driver suitable for operation on single phase 230 V, 50Hz, Ac supply with all accessories including, frame, diffuser, driver, interconnecting wires, earthing and fixing hardware's etc. as required.
Supply, installation, testing and commissioning of the 2' x 2' LED light fixture with minimum lumen output of 2400 lumens of recess mounting type LED Luminaire with Aluminium housing and opal diffuser 5700K colour temperature with driver suitable for operation on single phase 230 V, 50Hz, Ac supply with all accessories including, frame, diffuser, driver, interconnecting wires, earthing and fixing hardware's etc. as required.
Supply, installation, testing and commissioning of the LED Linear connected hanging type light fixture with minimum lumen output of 2000 lumens of recess mounting type LED Luminaire with Aluminium housing and 5700K colour temperature with driver suitable for operation on single phase 230 V, 50Hz, Ac supply with all accessories including, frame, diffuser, driver, interconnecting wires and with necessary SS hangings, earthing and fixing hardware's etc. as required.
Supply, installation, testing and commissioning of LED EXIT signage as per consultant's Emergency Lighting with 3Hrs Battery back up with driver suitable for operation on single phase 230V, 50Hz, Ac supply with all accessories including connection with 1.5sq mm FRLS PVC insulated copper conductor, single core cable and earthing etc. as required.
Supply, installation, testing and commissioning of energy saving 1200mm sweep BEE-5 star rating AC ceiling fan including wiring for down rods of standard length (up to 30 cm) with 1.5 sq.mm FRLS PVC insulated copper conductor cable etc. as required (But without regulator).
Supply, installation, testing and commissioning of 300mm sweep Heavy duty BEE-5 star rating exhaust fan with guard suitable operation on single phase 230V, 50Hz. AC Supply, with lowers / shutters in the existing opening, making good the damage etc. complete as required
SUB HEAD - 7 : UPS & INVERTER SYSTEM
UPS: Design, manufacture, assembly, supply, installation, testing, delivery and commissioning of UPS. General Requirement of UPS: 1) General Safety of UPS : IEC 62040-1 2) EMC Requirements of UPS : IEC - 62040-2 3) UPS Classification According to IEC 6403-3 (VF-SS-111). 4) Noise : 1m @ =58dBA. 6) Operating Temp : Deg C - 0-50 Dec C. 7) Relative Huminity : (%RH) 5 - 95. Non onsidering. 8) Efficiency : Online Mode - Up to 96.5%, Eco Mode - Up to 99%. INPUT: 9) Voltage:380/400/415VAC 3Phase 4Wire. 10) Voltage Range : 176-288V AC. 11) Frequency : 50HZ 12) Frequency Range : 40-70HZ 13) Power Factor (KW/KVA) : 0.99. 14) Current THD @ Linear Load (THDi%)-<3% 15) Rectifier Type - IGBT. OUTPUT: 16) Voltage :380/400/415. 17) Frequency : 50HZ. 18) Rated Power Factor(KW/KVA) : Utility. 19) Over Load Capacity : 25deg.C 105%-125%-5min,125%-150%-1min,150% 200ms. BATTERY: 20) Battery Per String : 30,32,34,36,38,40 21) Battery Max Power(A): 13A.
4 x 20 kVA UPS (60+20kVA) (PRS) of Continuous rating, Built in Isolation & web monitor Card online, double conversion mode input supply of 415 Volts ± 15%, 3 Phase, 50 Hz ± 5% and an out put of 415 Volts ±1%, 3Phase 50 ± 0.01 Hz, UPS system with IGBT rectifier. The UPS Cabinet to host 4 x 20 kVA shall consist of a Breaker & breaker cabinet, static/manual bypass switches, Surge surpreser rectifier / charger, a three-phase inverter, static transfer switch, logic, synchronizing equipment, protective devices and accessories, display module shall show clear graphical / text based overview of alarms, status data & instructional help, Isolation Transformer, Bottom cable entry provision, with necessary BMS compatibility (Hardware & software items for third party integration) with MODBUS protocol - RS 485 and accessories as required for proper operation. UPS DC Volt Minimum 360VDC Maximum 480VDC. The system should be suitable for independent mode of operation. Supply, Installation, Testing and commissioning Battery bank for 4x20kVA (60+20kVA) load. The battery should be of SMF VRLA, 12V, with end cell voltage of 1.75V of approved makes to give 30 Mins backup at 80 kVA load at 0.8 load power factor. Suitable MS Stand of Anti-Static Powder Coted Battery Rack Battery Interlink cable Uni Nyvin Cable With PPMA Sheet for protecting Battery From Earth Fault / Static Discharge and Fire Safety. Installation, Testing and Commissioning of complete 60+20 KVA UPS system in Independent mode of operation with the battery bank including inter connection of UPS and battery banks with adequate size of copper cable, lugs etc… all accessories as required as per site conditions. INVERTER: Supply, erection, testing and commissioning of the following rating of inverter Systems for emergency lightings. Make - Inverter : MICROTEK / LUMINOUS
Micro Processor Controlled 3 KVA inverter of input supply of 230Volts ± 15%, 3 Phase, 50 Hz ± 5% and an out put of 230 Volts ±1%, 1Phase 50 ± 0.01 Hz consisting of Rectifier, Inverter, Static and all others accessories required . Tubular Batteries to support 3 KVA for 30 minutes complete with inter cell connectors, battery stand made out of Powder Coated MS Angles with adequate supports to carry the load of the batteries as per specification. Installation, Testing and Commissioning of complete 1 no. 3 KVA inverter system with the battery bank including inter connection of system and battery banks with adequate size of copper cable, lugs etc. complete as required.
Description of Work / Item(s)
Amount
EXTRA LOW VOLTAGE SYSTEM (ELV) :
Supply, Installation, Testing and Commissioning of Data, Voice, CCTV, Access Control system as per approved installation drawings with required accessories as per site condition. General Requirement of ELV System : CORE SWITCH: 1) Layer : Layer -2 & Layer -3 managed switch min of 48-port 1/10G SFP+ ports stackable switch with additional 4xQSFP+ ports Should have the scalable options to support for 100G backbone network as well in future as per future network scalability requirements. The switch should for minimum 1 no of free slot for additional port requirements in future Dual FAN and hot swappable power supply for supporting load sharing/and redundancy Active/active clustering, VSS or equivalent technology for higher availability of Layer 2 and Layer 3 including video applications with flexi-and long-distance stacking based on network requirements. (we should have flexible stacking bandwidth as per required and minimum from day 1 it should support for 320Gbps. 2) Layer -2 Features : Supports for IEEE 802.3ac, IEEEE 802.3az, IEEE 802.1ab, IEEE 802.3ad, IEEE 802.1Q, IEEE 802.1s, IEEE 802.1w, IEEE 802.1D, IEEE 802.2, IEEE 802.3,IEEE 802.3ae, IEEE 802.3an, IEEE 802.3ba,IEEE 802.3bj, IEEE 802.3x, IEEE 802.3z, IEEE 802.1v, and Generic VLAN Registration Protocol for G.8032 or equivalent ring protection technology for 50ms (or lower). 3) Layer -3 Features : Static routing, RIP, RIPng, OSPF, OSPFv3, BGP4, BPG4+, PIM v4 SM, DM, SSM, DHCP server, DHCP & DNS client & relay, UDLD and also support for both IPv4 and IPv6 based on network.(Dual stack), VRFlite, supports Up to 64 Virtual Routing and Forwarding domains. 4) Performance : MAC address 96K entries, Jumbo frames 10KB Simultaneous, VLANs 4K 8K multicast entries, 4G RAM and 4G Flash memory. 5) Multicast : IGMP snooping v1 , v2 and v3, MLD snooping (v1 and v2). 6) Security Features : Layer 3, 4 ACL, AAA, BPDU protection, DHCP snooping, IP source guard, Dynamic ARP inspection, Dynamic VLAN assignment MAC address filtering, MAC address lock-down, NAC, Private VLAN, SSH, SSL v2 and v3, NTP, SNTP, TACAS+, Tri-authentication such as MAC-based , web-based and IEEE 802.1x port based authentications. 7) Management : SNMPv1, v2c and v3, TFTP, Web GUI, CLI, USB or memory card, Out-of-band 10/100/1000T Ethernet management port, Built-in text editor, Event-based triggers allow user-defined scripts and IPv4 and IPv6 management features. Supports for Open flow v1.3 and network management features such as auto backup, auto upgrade, Auto-provisioning and Auto recovery with easy centralized management solutions.
8) Monitoring : sFlow or an equal industry standard technology for monitoring high speed switched networks for end to end security monitoring to avoid any drops or security breach on the Fiber uplink links. 9) Quality of Services : Support for low latency with wire speed traffic classification essential for real time streaming and real time Video and voice applications. IEEE 802.1p standard, 8 priority queues, Policy-based QoS based on VLAN, port, MAC and general packet classifiers, IPv6 QoS support, storm protection, Queue scheduling options for strict priority, weighted round robin or mixed scheduling and should support for IP precedence and DiffServ marking based on layer 2, 3 and 4 headers. 10) Switching Capacity : High-capacity 1.92 Terabit fabric and 1,190Mpps.packet forwarding and provide powerful data transfer capability. 11) Operating Temperature : 0°C to 50°C (32°F to 122°F). 12) Operating Humidity (non- condensing) : 5% to 90% . 13) Certification : EMC: EN55032 class A, FCC class A, VCCI class A, Immunity: EN55024, Standards: UL60950-1, CAN/CSA-C22.2 No. 60950-1-03, EN60950-1, EN60825-1, AS/NZS 60950, Certification: UL, cUL, TUV and RoHS. For ease of interoperability, all the switches and transceivers should be from same OEM.
DATA NON POE SWITCH: 1) Layer : Layer -2 & Layer -3 managed switch. 16 / 24 10/100/1000 Base-T ports and additional 2 -1G SFP slots, 2 -10G SFP+ ports for uplinks Active / active clustering / VSS or equivalent technology for high availability of Layer 2 and Layer 3 including video applications with clustering bandwidth of 40Gbps each unit. 2) IEEE 802.3ac, IEEE802.3ad, IEEE 802.1Q, IEEE 802.1s, IEEE 802.1w IEEE 802.1D and IEEE802.1v, Should support for link aggregation (IEEE 802.1ax) for both static and LACP, The switch must support ring protection technology for Sub 50Ms (or lower) convergence time. 3) Layer -3 Features : Static routing, RIP, DHCP & DNS client and relay and IPv6 features. 4) Performance : MAC address 16K entries, Jumbo frames 9KB , Priority Queues 8, 512 MB DDR SDRAM and 64 MB Flash memory. 5) Multicast For Video: IGMP snooping v1 , v2 and v3, MLD snooping (v1 and v2). 6) Security Features : SSH, SSL v2 and v3, NTP, TACAS+, ACLs, DHCP snooping, IP source guard and dynamic ARP Inspection (DAI), MAC address filtering and MAC address lock-down, Dynamic VLAN assignment, Tri-authentication such as MAC-based web-based and IEEE 802.1x port based authentications and NAC for managing endpoint security. 7) Management : SNMPv1, v2c and v3, Web GUI, CLI, USB or equivalent memory card, and should support for both IPv4 and IPv6 management features and Control plane prioritization Should support for centralized management, auto-backup, auto-upgrade, auto-provisioning and auto-recovery for seamless and simplified network operations and management. 8) Monitoring : sFlow or an equal industry standard technology for monitoring high speed switched networks. Should support for UDLD, port mirroring and Optical DDM to monitor the various parameter of the transceivers.
9) Quality of Services : Must support for wire speed QoS, flow-based traffic management with full classification, prioritization, traffic shaping and min/max bandwidth profiles to provide better network performance and guaranteed delivery for time-critical services such as voice and video. Should support for IEEE 802.1p standard, Policy-based QoS based on VLAN, port, MAC and general packet classifiers. 10) Switching Capacity : Non-blocking switching and wire speed forwarding rate. 11) Operating Temperature : Min of 0 to 50 Degrees. 12) Certification Standards : UL/EN- 60950-1, EMC: EN55022 class A, FCC class A, VCCI class A, ICES-003 class A, and Immunity: EN55024 For ease of interoperability, all the switches and transceivers should be from same OEM.
DATA POE SWITCH: 1) Layer : Layer -2 & Layer -3 managed a) 16 Port 10/100/1000 Base-T and additional 2 -1G Base-X ports. Should support minimum 245 watts PoE budget that supports 802.3at. b) 24 Port 10/100/1000 Base-T and additional 4 1G Base-X ports. Should support minimum 370 watts PoE budget that supports 802.3at 2) Layer -2 Features : Should support STP, RSTP, MSTP, IGMP v1/v2/v3 snooping, loop protection, STP root guard, Voice VLAN, loop protection, MLD snooping (MLDv1 and v2), IEEE 802.3ac, IEEE 802.1v, 16k MAC Table or more, PVST+ compatibility mode, RIP, static routing, capable to support IEEE 802.1Q, IEEE 802.1ad Provider bridges (VLAN stacking, Q-in-Q). 3) Resiliency : Support IEEE 802.17/equivalent for sub 50ms ring protection. 4) Security : Support ACL, DHCP (relay and client), IP Source guard, DAI, Private VLAN, Authentication ( MAC, Web and IEEE 802.3x), sflow, SSLv2 and SSLv3, TACACS+, LAG, IP precedence and DiffServ marking based on layer 2, 3 and 4 headers.
5) Management : CLI, GUI, USB interface for taking backup of software release files configurations, Digital optical monitoring, Time Domain Reflectometry/ equivalent, DHCPv6, DNSv6, Telnetv6 and SSHv6, NTPv6 client and server, RMON 4 groups, SNMPv3, LLDP-MED, IEEE 802.3az, IPv4 and IPv6 support, SDN open flow v1.3 ready. Should support single IP management of min 16 switches for ease of management. Should support Unidirectional Link Detection (UDLD) or equivalent to detect unidirectional links caused by incorrect fibre optic wiring or port faults and disable on fibre optics interfaces. 6) Operating Temperature : Min of 0 to 50 Degrees. 7) Certification Standards : Support UL, cUL, UL-EU, UL60950-1, CAN/CSA-C22.2 No. 60950-1-03, EN60950-1, EN60825-1, AS/NZS 60950. For ease of interoperability, all the switches and transceivers should be from same OEM. DATA CABLE: 1) DATA Wiring : CAT - 6A FTP 4 Pair. 2) Wi-Fi Wiring : CAT - 6A FTP 4 Pair. 3) VOICE Wiring : CAT - 6 U/UTP 4 Pair. 4) CCTV Wiring : CAT - 6 U/UTP 4 Pair. 5) Sheath Type : LSZH - Low Smoke Zero Halogen. 6) Conductor Size : 23AWG 8) Primary Insulation: Polyolefin. Make - Data Switch : Allied Telesis / Cisco/ Juniper Make - Patch panel : MOLEX /Legrand / Commscope-systimax Make - Data Cable : MOLEX / Legrand / Commscope-systimax Make - Data Rack : VALRACK / NETRACK Make - CCTV & NVR : HONEYWELL / BOSCH / HIKVISION / NORDEN
SUB HEAD -1 : DATA SYSTEMS
Supply, installation, testing and commissioning of 24 port Layer 2 managed switch of 10/100/1000 base T port with 2 Nos of 1G Fibre Slots and 2Nos 10 Gig slots (loaded with 2 no of 10GSR 850 nm short-haul, 300 m with MMF module). The equipment shall have EEE (IEEE 802.3az) with Indian power cord. The switch shall be mounted on existing rack. The rate shall also include providing end termination and connection etc. with required all accessories. (FOR DATA SYSTEM)
Supply, installation, testing and commissioning of Core switch with High Capacity Stackable Layer 3+ Modular Switch loaded with Dual Hot-swappable load-sharing power supply, 17 No's of 10G SFP+ SR modules, 24 No's of 1G MM SFP modules, Advanced Layer 3 License, 40G QSFP+ Ports with QSFP+ Direct attach Stacking cable.
Supply and fixing of patch panel with CAT-6A STP JACK I/O mounted on existing rack with all necessary fixing accessories. The rate shall include cost of ferrule, numbering, stickering & necessary fixing accessories as required. 1U-Cat 6A- 24 Port loaded - Patch panels with Shuttered STP JACK & Rear wire manager .
Supply, Installation, Testing and Commissioning of U/FTP shielded Category 6A , 4 pair, 23 AWG solid copper conductor, 500 MHz, LSZH Cable (for 10G application) in the existing surface /recessed / FRLS PVC conduit as etc. (for Data ) The rate shall include cost of ferrule, numbering, stickering & necessary fixing accessories as required.
Supply, Installation, Testing and Commissioning of U/FTP shielded Category 6A , 4 pair, 23 AWG solid copper conductor, 500 MHz, LSZH Cable (for 10G application) with clamps at different intervals with all accessories as required as per site conditions as etc. (for Data ) The rate shall include cost of ferrule, numbering, stickering & necessary fixing accessories as required.
Supply, Installation, testing and commissioning of CAT-6A Shuttered STP Information Outlet - Blue colour with suitable Face plate and GI back box with all accessories as required as per site conditions at user end.
Supply, Installation, Testing & Commissioning of Cat 6A -FTP LSZH Patch cords - 2 mtr Blue at rack end.
Supply, Installation, Testing and Commissioning of Cat 6A -FTP LSZH Patch cords - 3mtr Blue at user end.
Supply, Installation, Testing & Commissioning of Fiber 1U LIU Loaded with OM3-LSZH LC pigtails and LC adapter with splice trays on existing rack with all necessary fixing accessories. The rate shall include cost of ferrule, numbering, stickering & necessary fixing accessories as required.
12 Port Fiber panel rack mounting LIU Loaded with Splice tray , LC pigtails and LC Adapter.
24 Port Fiber LIU Loaded with Splice tray , LC pigtails and LC Adapter.
Supply, Installation, Testing and Commissioning of LC - LC - Patch cords, MM OM3 bending insensitivity, 2mm Duplex, LSZH - 2Mtr.
Supply, Installation, Testing & Commissioning of 6 Core Multi Mode - OM3 Outdoor ECCS Armoured Unitube - PE, 1500N Tensile Strength, 2000N Crush Resistance and OD 9mm. Low Smoke Zero Halogen (LSZH), Gel-Filled OFC Cable in the existing duct as reqd.
Supply and fixing for the surface /recessed / concealed PVC FRLS conduit of thickness not less than 2mm conform to I.S. with all necessary conduit accessories such as junction boxes bends, couplings etc.
25mm Dia. Conduit.
32mm Dia. Conduit.
Supply, installation, testing and commissioning of 42U Rack 800mm width, 1000mm depth floor mounted, Front single front & Rear Perforated Door with lock , Cooling Fan 230V 90 CFM - 4Nos. Shelf 725mm -1No, Modem Tray - 1No, Power Strip 12 x 6/16A Socket & 1.5 meter feed cable and 3 pin plug -1No, 1U - Closed Cable manager 6Nos. with hardware Pocket of Assembled set and all necessary fixing accessories as required.
Supply and fixing for GI Floor trunking of the following sizes with all necessary accessories such as joints, bends, couplings etc.
100mm X 38mm -1 compartments GI Raceway.
100mm X 38mm Metal Fixing bracket.
Riser - 225mm
38mm coupling - Coupler for joining raceway
150mm X 150mm - Floor junction box with cover
225mm X 225mm - Floor junction box with cover.
SUB HEAD -2 : VOICE SYSTEM
Supply, installation, testing and commissioning of 24 port Layer 2 managed switch of 10/100/1000 base T port POE+ with 2Nos. 1Gig SFP MM port (loaded with 2 no of 1000SX GbE multi-mode 850 nm fiber up to 550 m module). The equipment shall have EEE (IEEE 802.3az) with Indian power cord. The switch shall be mounted on existing rack. The rate shall also include providing end termination and connection etc. with required all accessories. (FOR VOICE)
Supply and fixing of patch panel with CAT-6 UTP JACK I/O mounted on existing rack with all necessary fixing accessories. The rate shall include cost of ferrule, numbering, stickering & necessary fixing accessories as required. Cat 6 - 24 Port loaded - Patch panels with Shuttered UTP JACK ( yellow colour ) & Rear wire manager.
Supply, Installation, Testing and Commissioning of U/UTP Category 6, 4 pair, 23 AWG solid copper conductor, 500 MHz, LSZH Cable in (for100M/1G application). the existing surface /recessed / FRLS PVC conduit as etc. (for VOICE).
Supply, Installation, Testing and Commissioning of U/UTP Category 6, 4 pair, 23 AWG solid copper conductor, 500 MHz, LSZH Cable in (for100M/1G application). conduit with clamps at different intervals with all accessories as required as per site conditions as etc. (for Voice ) The rate shall include cost of ferrule, numbering, stickering & necessary fixing accessories as required. (for VOICE).
Supply, Installation, testing and commissioning of CAT6 Shuttered UTP Information Outlet-1No - Yellow colour with suitable PVC front plate and back box with all accessories as required as per site conditions.
Supply, Installation, Testing & Commissioning of CAT 6 -UTP LSZH Patch cords - 2 Mtr Grey at rack end.
Supply and fixing for the surface /recessed / concealed PVC FRLS conduit of thickness not less than 2mm conform to I.S. with all necessary conduit accessories such as junction boxes bends, couplings etc.
25mm Dia. Conduit.
32mm Dia. Conduit.
SUB HEAD -3 : CCTV SYSTEM
Supply, installation, testing and commissioning of 24 port Layer 2 managed switch of 10/100/1000 base T port POE+ with 2Nos. 1Gig SFP MM port (loaded with 2 no of 1000SX GbE multi-mode 850 nm fiber up to 550 m module). The equipment shall have EEE (IEEE 802.3az) with Indian power cord. The switch shall be mounted on existing rack. The rate shall also include providing end termination and connection etc. with required all accessories. (FOR CCTV)
Supply and fixing of patch panel with CAT-6 UTP I/O mounted on existing rack with all necessary fixing accessories. The rate shall include cost of ferrule, numbering, stickering & necessary fixing accessories as required. Cat 6 - 24 Port loaded - Patch panels with Shuttered UTP JACK ( grey colour ) & Rear wire manager .
Supply, Installation, Testing and Commissioning of U/UTP Category 6, 4 pair, 23 AWG solid copper conductor, 500 MHz, LSZH Cable in (for100M/1G application). the existing surface /recessed / FRLS PVC conduit as etc. (for CCTV)
Supply, Installation, Testing & Commissioning of CAT 6-UTP LSZH Patch cords - 2 Mtr Grey colour at rack end.
Supply, Installation, Testing & Commissioning of IP Network TDN Low-Light IR Dome Camera, 1/2.8" / 1/3" CMOS, 5 MP @ 25fps or better, triple stream, Min. Illumination required 0.2 lux @ F1.4 (colour), 120dB True WDR, Min. Pixels 2304×1296p, triple stream, 3mm - 12 mm motorized focus & zoom lens, Intelligent Video Analytics such as Tripwire, Object Removed, Object Left Behind, etc. Backlight Compensation, 3DNR, Privacy Mask, 3 IR LEDs Smart IR with up to 20m IR distance, H.264& MJPEG, Dual channel Audio G.711a/G.711u/AAC, 128GB SD card support, IP 67 & IK10, Alarm: 1 In & 1out, PoE, H.264 High Profile and MJPEG, PoE Class 3/ 12V DC/24VAC, Die-Cast Aluminium Construction, Having Operating temp range : –30°C to 60° C. Certifications: ONVIF Profile S & Profile G compliant. Safety Certification : UL, CE, EN, FCC & RoHS compliant. Cyber security Certification : UL-CAP. including connections as per specifications complete as required.
Supply, Installation, Testing & Commissioning of IP Network TDN Low-Light IR Bullet Camera,1/2.8" / 1/3" CMOS, 5 MP @ 25fps or better, triple stream, Min. Illumination required 0.2 lux @ F1.4 (colour), 120dB True WDR, Min. Pixels 2304×1296p, triple stream, 3mm - 12 mm motorized focus & zoom lens, Intelligent Video Analytics such as Tripwire, Object Removed, Object Left Behind, etc. Backlight Compensation, 3DNR, Privacy Mask, 3 IR LEDs Smart IR with up to 20m IR distance, H.264& MJPEG, Dual channel Audio G.711a/G.711u/AAC, 128GB SD card support, IP 67 & IK10, Alarm: 1 In & 1out, PoE, H.264 High Profile and MJPEG, PoE Class 3/ 12V DC/24VAC, Die-Cast Aluminium Construction, Having Operating temp range : –30°C to 60° C. Certifications: ONVIF Profile S & Profile G compliant. Safety Certification : UL, CE, EN, FCC &RoHS compliant. Cyber security Certification : UL-CAP. including connections as per specifications complete as required.
Supply, Installation, Testing & Commissioning of IP 2U 64 Channel Network Video Recorder with Camera License. Up to 32 channels at 1080p, or 16 channels at 4 MP, or 8 channels at 8 MP H.265/H.264 decoding De-warp fisheye camera video in local and web user interface for 360 degree situational awareness. Internal storage supports 8 HDDs expandable up to 64 TB .
Supply, Installation, Testing & Commissioning of 6TB Hard disk.
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.06 MB
Download all tender documents and submit your bid