Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.0 LAccepted-AOC | ₹20.0 L Quoted ₹20.5 L | L1 | Accepted-AOC Accepted being L1 bidder |
| 2 | L2₹24.1 L+₹3.6 L (17.5%)Rejected-Finance AT PO CHANDIPUR BALASORE 756025 | BALASORE | BALASORE | ODISHA | 756025 | ₹24.1 L+₹3.6 L (17.5%) | L2 | Rejected-Finance Being L2 bidder |
| 3 | L3₹24.5 L+₹4.0 L (19.4%)Rejected-Finance NEAR CENTRAL SCHOOL BALASORE DIST BALASORE ORISSA 756 001 | BALASORE | BALASORE | ORISSA | 756001 | ₹24.5 L+₹4.0 L (19.4%) | L3 | Rejected-Finance Being L3 bidder |
| 4 | L4₹25.1 L+₹4.6 L (22.6%)Rejected-Finance PASCHIM BHAGABANPORE DARUA CONTAI PURBA MEDINIPUR 721401 | PURBA MEDINIPUR | PURBA MEDINIPUR | WEST BENGAL | 721401 | ₹25.1 L+₹4.6 L (22.6%) | L4 | Rejected-Finance Being L4 bidder |
| 5 | L5₹25.4 L+₹4.9 L (23.9%)Rejected-Finance SRIKONA CHANDIPUR BALASORE 756 025 | BALASORE | BALASORE | ORISSA | 756025 | ₹25.4 L+₹4.9 L (23.9%) | L5 | Rejected-Finance Being L5 bidder |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
23 Jan 2023, 6:00 pmClosed
Shri Avinash Mishra IDSE EE
Garrison Engineer (I) (CG) Bhubaneswar, Plot No 190/702, Kokila Residency, 2nd Floor, Anant Vihar, Post-Pokhariput, Bhubaneswar- 751020
REPAIR AND MAINTENANCE OF SOLAR WATER HEATER LT PANEL STREET LIGHTS BOLLARD LIGHTS AND FIRE FIGHTING ETC
2022_MES_571357_1
8345/BBSR/03/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
Paradip
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE (I) (CG) Bhubaneswar
₹40,000
Yes
4 Mar 2023
26 Dec 2022
25 Jan 2023
26 Dec 2022
23 Jan 2023
9 Jan 2023
Amount
Taking down carefully undergound cables of any sizes for testing, meggering and keeping serviceable cable and cable protection old bricks in safe costody for re-use with making good distubed surfaces,trenches or walls, floors etc complete all as specified & directed .
Supply and laying cable XLPE insulated screened PVC bedded,galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 Sqmm x 3.5 core complete all as specified and directed. (Make Polycab/Hevells/Glostar)
All as per item No-2 above but for 35 sqmm 3.5 core.
All as per item No-2 above but for 25 sqmm 3.5 core.
All as per item No-2 above but for 16 sqmm 4 core.
All as per item No-2 above but for 10 sqmm 4 core.
All as per item No-2 above but for 10 sqmm 2 core.
Relying old serviceable cable any size and type obtained from Ser No-1 above complete all as specified and directed. Note :- Earth work to be measured and paid separately.
Excavation in trenches not exc 1.5m deep and n.exc 1.5m wide and getting out in soft/loose soil for laying of cable and foundation of Pole complete all as specified and directed.
M&L for sand coushioning with dry and clean over and under the cable for protection of cable , 180 mm sand laid before laying the cable & 150 mm sand after laying the cable and filling the sand in cable duct inside the sub station building complete all as specified and directed.
Returning, filling in, including spreading, leveling watering and well ramming in layer not exceeding 25 Cm complete all as specified and directed.
Removing of excavated material not exceeding 50 m and depositing where directed at level not exceeding 50 M and depositing where directed at a level not exceeding 1.5 M above the starting point complete all as specified and directed.
M&L for laying of bricks locally available sub class 'B' bricks (old size) for cable protection cover laid flat and dry in trenches over the cable prependicular to the direction of cable complete all as specified and directed.
Re-laying of old serviceable bricks retreived from Sl No.1 here-in before for cable protection cover laid flat and dry in trenches over the cable prependicular to the direction of cable complete all as specified and directed.
Supply and laying of GI tubing light grade 40 mm with all fittings laid in trenches/road crossing/along the pole for protection of cable including taking out old GI tubing and making surface in condition complete all as specified and directed. (Make:- Jindal/Prakash/Tata)
Supply and laying of GI tubing light grade 50 mm with all fittings laid in trenches/road crossing/along the pole for protection of cable including taking out old GI tubing and making surface in good condition complete all as specified and directed. (Make:- Jindal/Prakash/Tata)
Supply and laying of GI tubing light grade 80 mm with all fittings laid in trenches/road crossing/along the pole for protection of cable including taking out old GI tubing and making surface in good condition complete all as specified and directed. (Make:- Jindal/Prakash/Tata)
Cutting chases,pinning in,making good of PCC hard standing to facing where required and pointing in cement mortar 1:3 , exc.10 cm. but not exc.20 cm girth to ends or edges of landing,steps,cills,sunshades,shelves,lintels,etc.and cutting chases for concealed water tubing or concealed conduit wiring,laying of cables and making good with old shape and size complete all as specified and directed.
Cutting Bituminous road in,making good with facing where required and pointing exc.30 cm. but not exc.1.0 mtr. girth to ends or edges of landing,steps,cills,sunshades,shelves,lintels,etc.and cutting chases for concealed water tubing or concealed conduit wiring,laying of cables and making good with old shape and size complete all as specified and directed.
Repair/maintainace of LT cable faults by disconnecting and taking out old existing defective LT cable of any sizes,in any position from trench/duct, removing/excavating the outer surface of cable, examining cable and joints for defects and ascertaining suitability of cable for reuse, cutting out the defective portion of cable/joint, including taking out old serviceble PCC cable covers/Bricks or GI pipe of any type/sizeand relaying the cable with old bricks after repair/replacement of cable / jointing kit of any make or size of existing then make good the excavated area by returning/filling the same complete all as specified and directed. ( NOTE:- Using of new GI pipe or new jointing kit will be paid separately in concerned items )
Material and labour for heat shrikable type LT Jointing kit for 1.1 KV XLPE cables of size 10-16 sqmm 4 core straight through joint complete including taking down old one complete all as specified and directed. (Make Densons,Item Code-XSSO-3or equivalent of Multishrink/ 3M)
Material and labour for heat shrikable type LT Jointing kit for 1.1 KV XLPE cables of size 25-50 sqmm 3.5/4 core straight through joint complete including taking down old one complete all as specified and directed. (Make Densons,Item Code-XSSO-4 or equivalent of Multishrink/ 3M)
Material and labour for heat shrikable type LT Jointing kit for 1.1 KV XLPE cables of size 70-120 sqmm 3.5/4 core straight through joint complete including taking down old one complete all as specified and directed. (Make Densons,Item Code-XSSO-5 or equivalent of Multishrink/ 3M)
Repair and maintenance of broken door of LT indoor/outdoor feeder pillar box/ LT panel by welding or any other repair work as per site requirement repair/ maintenance of hinges, replacement of locking system and ensure open/close the door smoothly, repair/ maintenance of bus bar if any, replacement of MCBs & MCCBs where necessary , providing all necessary arrangement nut bolt thimbles, lugs ferrules, glands of suitable and replacing the old worn out internal wirings by suitable size of FRLS copper cable complete all as specified and directed ( NOTE- The minor Spares like nuts, bolts,screws,washers,Insulation Tapes, Busbar Sleeves used in repair works are included in the scheduled item rates. The spare parts like MCBs,MCCBs etc. will be paid separately )
M&L for Painting of LT outdoor/indoor Feeder pillar box/ LT panel with two coats of synthetic enamel paint, smoke grey colour (1st quality) over a coat of primer by preparing the surface area by rubbing and scraping old rusted areas and welding/patching with new MS sheet make good as its won position before the 1st coat of complete all as specified and directed.
Supply and fix Bus bar Chamber TPN 100 Amps including aluminium busbar with 4 O/G Ways and all accessories with MS angle and frames including taking down old unserviceable bus bar box complete all as specified and directed. Make- C&S/Havells /Indoasian or Equivalent
Supply and fix Bus bar Chamber TPN 200 Amps including aluminium busbar with 4 O/G Ways and all accessories with MS angle and frames including taking down old unserviceable bus bar box complete all as specified and directed. Make- C&S/Havells/C&S /Havells/Indoasian or Equivalent
Supply& Fixing MCB, SP, 40 Amps, 240 volt, 'C' Series, 10 kA complete all as specified and directed. ( Make L&T,Cat No.BB10400B or Standard/ Legrand/C&S/Havells/Indoasian )
Supply& Fixing MCB, SP, 6-32 Amps, 240 volt, 'C' Series, 10 kA complete all as specified and directed. ( Make L&T,Cat No.BB10320B or Standard/ Legrand/C&S/Havells/Indoasian )
Supply & Fixing MCB, SPN.40 Amps rating 240, volt, 'C' series, 10 kA complete all as specified and directed. (Make L&T,Cat No.BB20400B or Standard / Legrand/C&S/Havells/Indoasian )
Supply & Fixing MCB, SPN. 6-32 Amps rating 240, volt, 'C' series, 10 kA complete all as specified and directed.(Make L&T,Cat No.BB20320C or Standard /Legrand/C&S/Havells/Indoasian )
Supply & Fixing Isolator, TPN,63 Amps rating 240, volt, 'C' series, 10 kA complete all as specified and directed. (Make L&T/ Standard /Legrand/C&S/Havells/Indoasian )
Supply & Fixing Isolator, TPN,100 Amps rating 240, volt, 'C' series, 10 kA complete all as specified and directed.(Make L&T/ Standard / Legrand/C&S/Havells/Indoasian )
Supply & Fixing in repairs MCCB of 500-630 Amps,4 pole ,with Thermal -Magnetic Release , DN3-630N type with breaking capacity Icu at 415 volts AC,50Hz , 36 Ka, including spidel links both side incoming/outgoing side, connection and and testing complete all as specified and directed. Make/Model- L&T, DN3-630N, Cat No CM94004OOT1OG or equivalent make of STandard/Legrand/C&S/Havells/ Indoasian)
Supply & Fixing in repairs MCCB of 400 Amps,4 pole ,with Thermal -Magnetic Release , DU400N type with breaking capacity Icu at 415 volts AC,50Hz , 50 kA including spidel links both side incoming/outgoing side, connection and and testing complete all as specified and directed. Make/Model- L&T, DN3-630N, Cat No CM94004OOT1OG or equivalent make of STandard/Legrand/C&S/Havells/ Indoasian)
Supply & Fixing in repairs MCCB of 250 Amps,4 pole ,with Thermal -Magnetic Release , DU250 type with breaking capacity Icu at 415 volts AC,50Hz , 36 kA including spidel links both side incoming/outgoing side, connection and and testing complete all as specified and directed. Make/Model- L&T, DN3-630N, Cat No CM94004OOT1OG or equivalent make of STandard/Legrand/C&S/Havells/ Indoasian)
Supply & Fixing in repairs MCCB of 200 Amps,4 pole ,with Thermal -Magnetic Release , DU250 type with breaking capacity Icu at 415 volts AC,50Hz , 36 kA including spidel links both side incoming/outgoing side, connection and and testing complete all as specified and directed. Make/Model- L&T, DN3-630N, Cat No CM94004OOT1OG or equivalent make of STandard/Legrand/C&S/Havells/ Indoasian)
Supply & Fixing in repairs MCCB of 125 Amps,4 pole ,with Thermal -Magnetic Release , DU125H type with breaking capacity Icu at 415 volts AC,50Hz , 16 kA including spidel links both side incoming/outgoing side, connection and and testing complete all as specified and directed. Make/Model- L&T, DN3-630N, Cat No CM94004OOT1OG or equivalent make of STandard/Legrand/C&S/Havells/ Indoasian)
Supply & Fixing in repairs MCCB of 100 Amps,4 pole ,with Thermal -Magnetic Release , DU100H type with breaking capacity Icu at 415 volts AC,50Hz , 16 kA including spidel links both side incoming/outgoing side, connection and and testing complete all as specified and directed. Make/Model- L&T, DN3-630N, Cat No CM94004OOT1OG or equivalent make of STandard/Legrand/C&S/Havells/ Indoasian)
Supply & Fixing in repairs MCCB of 63 Amps,4 pole ,with Thermal -Magnetic Release , DU100H type with breaking capacity Icu at 415 volts AC,50Hz , 16 kA , including spidel links both side incoming/outgoing side, connection and and testing complete all as specified and directed. Make/Model- L&T, DN3-630N, Cat No CM94004OOT1OG or equivalent make of STandard/Legrand/C&S/Havells/ Indoasian)
Supply & Fixing , in replacement, PVC copper cable 3-in core of size 1.5sq mm for junction box to street light fitting connection complete all as specified and directed. (Make: Finolex/ Polycab/ Plaza)
Supply & Fixing, in replacement, PVC conduit pipe of size 20mm for protection of copper wire to be fixed on elect pole complete all as specified and directed. (Make: Plaza/Precision/prestoplast)
Supply & Fixing, in replacement, flexible hose pipe of size 20mm protection of copper wire complete all as specified and directed.(Make: Plaza/Precision/prestoplast)
M&L for cleaning,scrubing and preparation of surfaces of PCC pole and carrying out following phase of work complete all as specified and directed. (a) Cement Base paint on all the sides of PCC pole, area above the zebra painting all as specified & directed. (b) carrying out painting by synthetic enamel paint one coat over the concrete surface of pole using black and yellow paint all as directed area above the pole coping upto 1.5 mtr and numbering the pole all as specified (c) Silver colour spray painting of mild steel bracket, clamps and nut, bolts all as specified and directed.
M&L for repair of damaged LT Panel Foundation & coping of PCC pole by Brick work, plastering and weather coat paint of PCC coping area complete all as specified and directed.
Taking down carefully unserviceable LED Street lights/Security lights/Flood lights fittings of any type and capacity from pole/ wall with dismantling the light fittings , checking its serviceability circuit board ,driver units,and carried out necessary repairs/soldering of worn out circuits /connections ,replacement of unserviceable parts and refixing the same after repair including connecting and testing the same complete all as specified and directed. (NOTE:- Replacement of old unserviceable spare parts shall be measured and paid separately under supply only items.
Supply and Fix Driver unit suitable for LED street light fittings of 60 watts as per site requirement complete all as specified and directed. Make- Crompton/Phillips/C&S/ Surya/Havells/Bajaj
Supply and Fix Driver unit suitable for LED street light fittings of 45 watts as per site requirement complete all as specified and directed. Make- Crompton/Phillips/C&S/ Surya/Havells/Bajaj
Supply and fix MCPCB unit suitable for LED street light fittings of 45 watts complete all as specified and directed. Make- Crompton/Phillips/C&S/Surya/Havells/Bajaj
Supply and fix MCPCB unit suitable for LED street light fittings of 60 wattscomplete all as specified and directed. Make- Crompton/Phillips/C&S/Surya/Havells/Bajaj
Supply & fixing in repair street light fitting,Aesthentically designed roadway luminiare with heat resistant excellent thermal management IP 65 powder coated pressure die cast aluminium compact high power LED street light with heat resistant toughhened glass with lens of capacity 45 watt of efficacy :-110LM/W including provn of necessary connection complete including taking down old fittings complete all as specified and directed.( Make/ Model:- Crompton,(FREEDOM NEO), Cat No . LSTS-45-CDL-M or equivalent of Wipro/Philips
Supply & fixing in repair street light fitting,Aesthentically designed roadway luminiare with heat resistant excellent thermal management IP 66 powder coated pressure die cast aluminium compact high power LED street light with toughhened glass with lens of capacity 60 watt of efficacy :-110LM/W including 10KV SPD and provn of necessary connection complete including taking down old fittings complete all as specified and directed.(Make/ Model:- Crompton,(ORION NEO), Cat No .LST-60-CDL-M or equivalent of Wipro/Philips
Supply & Fixing in repairs decorative LED post top lantern for 360 deg indirect light with IP 65 protection with resistant to impact and corrosion,Glare-free and better uniformity , diffuser and painted aluminium reflector 40 watt complete all accessories necessary fitting including connection of 1.5 Sqmm copper conductor cable PVC insulated unsheathed 1100 volts grade , testing before and after mounting for proper function complete including taking down old fittings complete all as specified and directed.(Make/ Model:-Crompton,(MAPLE), Cat No . LPTO-40-CDL or equivalent of Wipro/Philips
Supply & fixing in repair Garden Bollard light fitting with robust design , IP 65, Polycarbonate cover high power LED light of capacity 10 watt.including provn of necessary nuts,bolts and washers for installation on and with foundation and connection complete including taking down old fittings complete all as specified and directed.(Make/ Model:- Crompton,(LIARA), Cat No . LBLSN-10-CDL or equivalent of Wipro/Philips
Supply & Fixing in repairs high power LED floodlight with innovative thermal management and available in multiple optics and equipped with IP66 protection,pressure die-cast aluminium housing complete with all accessories of capacity 200 watt including 10KV SPD with provn of necessary connection complete including taking down old fittings complete all as specified and directed. (Make/ Model:- Crompton,(PLUTO NEO), Cat No . LFLN-200-CDL/60-M or equivalent of Wipro/Philips
Supply& Fixing in repairs high power LED floodlight with innovative thermal management and available in multiple optics and equipped with IP66 protection,pressure die-cast aluminium housing complete with all accessories of capacity 150 watt including 10KV SPD with provn of necessary connection complete including taking down old fittings complete all as specified and directed. (Make/ Model:- Crompton,(PLUTO NEO), Cat No . LFLN-150-CDL/60-M or equivalent of Wipro/Philips
Supply and fixing in repair of GI pipe Bracket of 40 mm dia light grade pipe bend to shape of approx length 1.5 Mtr including 2 no. MS Clamp of flat iron size 40x6 mm complete with nut, bolt, washers complete all as specified and directed. (Make of GI pipe- Jindal/Prakash/Tata)
Supply & Fixing repairs cable junction box made of thermoplastic, halogen free, weather proof with metric Knock outs for cable entry including four/five pole terminals and cable entry glands for incomming, out going and connection cable with protection grade IP-66/67 of size 205x255x112 mm and suitable for LT under ground cable any size/capacity including with MCB SP 10 Amps, bracing clamp,bolts,nuts & washers complete all as specified and directed.(Make Hensel/ model No-KF2525B or Rittal, Schneider, GE)
Trimming /cutting of tree branches /bushes obstructing the Street Light Poles/LT lines making clear distance of 2.0 meter upto 5/6 branches at one site for one job from the outer conductors of OH Lines/ poles all around including removing of branches/bushes of trees from site upto 50 Mtrs from the site complete all as specified and directed.
Dismantling and taking out old un-serviceable Solar Water heater from any height or any position with checking and disconnecting its hot and cold water pipe lines connection and unserviceable parts ,such as heating chamber, collecting pannel,hot water tank, water reservers and water make up tank etc and replace the minor spare parts and accessories including adequete/existing length and size inlet/outlet hot/cold water pipes connected with Solar water heater system and refitting the same in its own position including servicing the all parts and equipments of existing Solar Water Heater of capacity 500 LPD of Make/Model:-Racold ( Omega Max 8 ) and testing complete all as specified and directed.
Dismantling and taking out old un-serviceable Solar Water heater from any height or any position with checking and disconnecting its hot and cold water pipe lines connection and unserviceable parts ,such as heating chamber, collecting pannel,hot water tank, water reservers and water make up tank etc and replace the minor spare parts and accessories including adequete/existing length and size inlet/outlet hot/cold water pipes connected with Solar water heater system and refitting the same in its own position including servicing the all parts and equipments of existing Solar Water Heater of capacity 200 LPD of Make/Model:-Racold ( Omega Max 8 ) and testing complete all as specified and directed.
Dismantling and taking out old un-serviceable Solar Water heater from any height or any position with checking and disconnecting its hot and cold water pipe lines connection and unserviceable parts ,such as heating chamber, collecting pannel,hot water tank, water reservers and water make up tank etc and replace the minor spare parts and accessories including adequete/existing length and size inlet/outlet hot/cold water pipes connected with Solar water heater system and refitting the same in its own position including servicing the all parts and equipments of existing Solar Water Heater of capacity 100 LPD of Make/Model:-Racold ( Omega Max 8 ) and testing complete all as specified and directed.
Supply and fixing Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I of capacity 500 ltrs to be fitted with Solar water heater system of capacity 100 LPD/200 LPD with taking down old one complete all as specified and directed. Make : - Sintex / Polycab or equivalent .
Supply and fixing Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I of capacity 750 ltrs to be fitted with Solar water heater system of capacity 500 LPD with taking down old one complete all as specified and directed. Make : - Sintex / Polycab or equivalent .
M&L for earthing complete with galvanized steel earth plate 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25 Mtr deep below normal ground level) with top edge of plate not less than 1.5 Mtr below normal ground level connected to galvanised iron strip 25×4mm as earthing lead by means of check nuts and washer of galvanized iron or steel including 40 mm dia GI pipe light grade upto 1.5 mtr below ground level for protection pipe ,excavation and earth work charcole dust, common salt PCC 1:3:6 type C-I using 20 mm stone aggregate for chamber and MS angle iron frame 40x40x3mm and RCC cover 40 mm thick (1:2:4) type BI using 20 mm graded stone aggregate reinforced with 8 mm dia TMT bars @ 75 mm c/c both ways with MS handle 12 mm dia, round ,PGI funnel and wire mesh, 20 mm dia GI pipe light grade for watering all as shown in Plate no 3 of SSR Part I of 2009 and connected to earth test point incl testing complete all as specified and directed . Note :- Cost of earthing strip & GI pipe 25mm up to 7.5 m shall be included in cost of above item.
Repair, maintenance and servicing of Boom Barrier, Control Panel and its connected Accessories included all spair Parts in Same Item complete all as specified and directed. (Make Godrej)
Repair, maintenance and servicing of Tyre killer, Cleaning of tyre killer duct, removing of mud and repair of its control Panel and its connected Accessories like Gear Motor, Chain & movable Parts complete all as specified and directed.
Supply, install, testing & commissioning in repair LT Panel board , outdoor type, floor mounted, CRCA, made of sheet steel ,factory made suitable for 415 volt, 3 Ph 4 wire, 50 HZ, AC supply system of size not less than 1600 mm x 1200mm x 500 mm,open on both back and front side having hinges and locking arrangements having busbars chamber with Aluminium bus bars with vertically arranged of 400 Amps rating duly insulated by insulation of RYB colour mounted on porcelain insulators The panels shall be made out of 3.15 mm thick CRCA Sheet , powder coated based on MS channel for arrangement of foundation nuts , bolts and washers (Make:Universal Switch gear control/C&S/Neptune/Power system & Control). The Panel should be protected with IP 54 in accordance with IEC 60529. The gasket material shall be polyurethane,while the material shall be internally embedded. the Panel should be including with internal wiring with multistranded copper conductor cable of suitable size including lugs and cable gland to incoming and outgoing cable etc and supported on MS angle of size not less than 450 mm long, LED indicating lamps, current transformers, terminal block for cables and including making of suitable size foundations as per manufacturer recommendations and taking down old unserviceable panel /fidder pillars alongwith all accessories complete all as specified and directed at site and to incorporate the following:-
Note : (i) Existing all connections to be disconnected from old Panel and reconnected to New Panel complete testing and commissioning etc with all other connected civil works to be included in unit of works
(A) INCOMING (i) MCCB four pole 415 Volts AC Supply,DU100H, 160 Amps-01 Nos, thermal magnetic release type 36 kA, Rotary handle, Seperator link (Set of 8) 2 Nos.,Make:- L&T,Cat No:- CM979OOK2 or equivalent of Legrand/Schneider. (ii) Panel mounted Digital type,LED display,3phase, Volt meter for measuring Voltage (0-500 Volts)-01 Nos , flush mounting 96x96mm Make- L&T, Cat No- WL132010OOOO (iii)Panel mounted Digital type,LED display,3phase, Ampere meter for measuring of Current(0-500 Amps)-01 No, flush mounting 96x96mm Make- L&T, Cat No- WL131010OOOO
(B) OUTGOING (i) MCCB 4 Pole 415 Volts ,DU100H, 30 kA 63 Amp rating thermal magnetic release type-05 Nos, Make:- L&T,Cat No:- CM97933OOH2 or equivalent of Legrand/Schneider (ii) MCB (SPN) 40 Amps,'C' Series-01 Nos, Make:- L&T,Cat No:- BB20400C or equivalent of Legrand/Schneider
Supply, install, testing & commissioning in repair LT Panel board , outdoor type, floor mounted, CRCA, made of sheet steel ,factory made suitable for 415 volt, 3 Ph 4 wire, 50 HZ, AC supply system of size not less than 1600 mm x 1200mm x 500 mm,open on both back and front side having hinges and locking arrangements having busbars chamber with Aluminium bus bars with vertically arranged of 400 Amps rating duly insulated by insulation of RYB colour mounted on porcelain insulators .The panels shall be made out of 3.15 mm thick CRCA Sheet , powder coated based on MS channel for arrangement of foundation nuts , bolts and washers (Make:Universal Switch gear control/C&S/Neptune/Power system & Control). The Panel should be protected with IP 54 in accordance with IEC 60529. The gasket material shall be polyurethane,while the material shall be internally embedded. the Panel should be including with internal wiring with multistranded copper conductor cable of suitable size including lugs and cable gland to incoming and outgoing cable etc and supported on MS angle of size not less than 450 mm long, LED indicating lamps, current transformers, terminal block for cables and including making of suitable size foundations as per manufacturer recommendations and taking down old unserviceable panel /fidder pillars alongwith all accessories complete all as specified and directed at site and to incorporate the following:-
Note : (i) Existing all connections to be disconnected from old Panel and reconnected to New Panel complete testing and commissioning etc with all other connected civil works to be included in unit of works
(A) INCOMING (i) MCCB 4 Pole 415 Volts, DU250,36 kA 200 Amp.rating thermal magnetic release type - 01 Nos with rotary handle and separator link (Set of 8) 2 Nos Make:- L&T,Cat No:- CM98065OONO or equivalent of Legrand/C&S (ii) Panel mounted multi function meter Consiting of Volt meter for measuring Voltage (0-500 Volts), Ampere meter for measuring Current(0-500 Amps) and Frequency meter of 50Hz and PF Meter - 01 No.Make-L&T,Cat No-WL411011OOOO
(B) OUTGOING (i) MCCB four pole 415 Volts AC Supply,DU125H, 125 Amps, thermal magnetic release type 30kA,-01 Nos Rotary handle ,Seperator link (Set of 8) 2 Nos.,Make:- L&T,Cat No:- CM90678OOLO equivalent of Legrand/C&S. (ii) MCCB four pole 415 Volts AC Supply,DU100H, 100 Amps, thermal magnetic release type 30kA,-01 Nos Rotary handle ,Seperator link (Set of 8) 2 Nos.,Make:- L&T,Cat No:- CM97933OOK2 equivalent of Legrand/C&S. (iii) MCCB 4 Pole 415 Volts ,DU100H,30 kA 63 Amp .rating thermal magnetic release type- 03 Nos, Make:- L&T,Cat No:- CM97933OOH2 or equivalent of Legrand/C&S
M & L for closing water supply suction and delivery valve to the under ground sump of capacity 33000 gallon, cleaning and removing all dirty/muddy water from the sump using diesel driven non clogging pump, removing mud deposited on tank floor, scrubbing the inside walls using wire brushes, brooms to remove all fungus, scale formations, cleaning the inner surfaces of sump using bleaching powder and washing internal surface of the walls and applying one coat of white wash to the internal surface of sump writing details of tank like date of cleaning, due date of next cleaning and capacity of tank etc. on the out side of the tank with synthetic enamel paint with letter size 20 CM in white colour over black background of size 100x60CM complete all as specified and as directed.
M & L for closing water supply suction and delivery valve to the under ground sump of capacity 22000 gallon, cleaning and removing all dirty/muddy water from the sump using diesel driven non clogging pump, removing mud deposited on tank floor, scrubbing the inside walls using wire brushes, brooms to remove all fungus, scale formations, cleaning the inner surfaces of sump using bleaching powder and washing internal surface of the walls and applying one coat of white wash to the internal surface of sump writing details of tank like date of cleaning, due date of next cleaning and capacity of tank etc. on the out side of the tank with synthetic enamel paint with letter size 20 CM in white colour over black background of size 100x60CM complete all as specified and as directed.
M & L Prestressed concrete pole, 9.0 metres long, 102mm x 172mm at top and l02mm x 279mm at bottom, class 10 complete all as specified and directed
M&L for cement concrete type C2 1:3:6 using 40 mm graded aggregate complete for foundation bed complete all as specified and directed.
M&L providing for cement concrete in foundations, filling and mass concrete type D2 1:4:8 using 40 mm graded aggregate complete for filling mass concrete for pole complete all as specified and directed
M&L for cement concrete in foundations, filling and mass concrete type B1 1:2:4 using 20 mm graded aggregate complete for pole Coping complete all as specified and directed
Excavation in trenches n.exc 1.5mtr wide but exc 1.5 mtr in depth for each additional 1.5 mtr wide & exc 1.8 mtr in depth beyond the first 1.5mtr for foundation complete all as specified and directed.
M & L of MS Clamp of flat iron size 50x6 mm complete with nut, bolt, washers complete all as specified and directed.
DS ENTERPRISES
M/S T.N.CONSTRUCTION
RANA ENTERPRISES
vaishnaveedevienterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .