Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹1.4 CrAccepted-AOC SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON WEST MUMBAI 400 104 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | ₹1.4 Cr | L-1 | Accepted-AOC Being L-1 |
| 2 | L-2₹1.5 Cr+₹1.8 L (1.25%)Rejected-Finance SWAGAT CO OP HSG SOCIETY LTD 22 303 CHAITANYA SHIVAJI RAJE COMPLEX MHADA COMPLEX OPP EKA NAGAR KANDIVALI W MUMBAI 400 067 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400067 | ₹1.5 Cr+₹1.8 L (1.25%) | L-2 | Rejected-Finance Being L-2 |
| 3 | L-3₹1.5 Cr+₹4.9 L (3.39%)Rejected-Finance 1 2 GR FLOOR VITHALKUNJ NO 3 V P ROAD ANDHERI WEST MUMBAI 400 058 | MUMBAI SUBURBAN | MAHARASHTRA | 400058 | ₹1.5 Cr+₹4.9 L (3.39%) | L-3 | Rejected-Finance Being L-3 |
| 4 | L-4₹1.5 Cr+₹6.0 L (4.16%)Rejected-Finance PLOT NO 1134 1196 MORIVALI VILLAGE TAL AMBARNATH DIST THANE AMBERNATH 421505 | AMBERNATH | THANE | MAHARASHTRA | 421505 | ₹1.5 Cr+₹6.0 L (4.16%) | L-4 | Rejected-Finance Being L-4 |
| 5 | Rejected-Technical BLOCK C 14 GROUND FLOOR PLOT 618 624 BHIVANDIWALA TERRACE JAGANNATH SHANKARSHETH MARG DHOBI TALAO NEAR KALBADEVI POST OFFICE MUMBAI 400002 | MUMBAI | MAHARASHTRA | 400002 | - | - | Rejected-Technical Due to not enlisted in c(iii) category as per NIT |
Tender Value
₹1.5 Cr
EMD Value
₹2.2 L
Closing Date
18 Nov 2024, 6:00 pmClosed
CWE (SUBS) MUMBAI
Commander Works Engineer Subs NCHC Powai Bhandup Post Office Mumbai 400 078
OUTSOURCING OF SERVICES FOR MANNING AND OPERATION OF WATER SUPPLY INSTL, DG SET AND MAINT TO DG SET, AMF PANEL AT 31 WEU, NTS MAHUL, NSD SEWRI AND REPAIR/ MAINT OF EOT AND HOT CRANE AND ALLIED WORKS AS SPECIFIED IN SCOPE OF WORK UNDERGE (NW) MANKHURD
2024_MES_680579_1
8879/E8
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
MANKHURD
Please refer Tender documents.
8 documents required · 8 mandatory
₹1,000
GE (NW) MANKHURD
₹2.2 L
Yes
10 Jan 2025
21 Oct 2024
21 Nov 2024
21 Oct 2024
18 Nov 2024
11 Nov 2024
Amount
Manual Rescue and operation Rescue of water supply installation with all connected equipments, electric driven pump set, 20,000 Gph, supply lines and machineries (as listed herein under) and internal and external electrification, external water supply system, sumps, overhead reservoirs, service tanks, etc with one operator / technician operation for (01 No/Shift) for 02 shifts, (08 hours each shift) including Sundays and holidays including routine maintenance checks and upkeeping the installation and with the under laid components complete all as specified and as directed by the Engineer-in-charge. Location : Mahul (i) 1st shift - 0600 hrs to 1400 hrs (ii) 2nd shift - 1400 hrs to 2200 hrs Machineries: (a) Pumping set 25HP - 02No. (b) Pumping set 20HP - 02No. (c) Pumping set 5HP - 02Nos. (d) Electric control panel - 02No Note : - Any malfunctioning noticed during the entire contract period on account of negligence of the operaters , the cost of Repair /replacement of defective parts shall be recoveredfrom any dues from the contractor. Decision of the Eng - in Charge on this subject shall be final and binding.
Manual Rescue and operation Rescue of water supply installation with all connected equipments, electric driven pump set, 20,000 Gph, supply lines and machineries (as listed herein under) and internal and external electrification, external water supply system, sumps, overhead reservoirs, service tanks, etc with one operator / technician (01 No/Shift) for 02 shifts, (08 hours each shift) including Sundays and holidays including routine maintenance checks and upkeeping the installation and with the under laid components complete all as specified and as directed by the Engineer-in-charge. Location : Sewri (i) 1st shift - 0600 hrs to 1400 hrs (ii) 2nd shift - 1400 hrs to 2200 hrs Machineries: (a) Pumping set 25HP - 02No. (b) Pumping set 10HP - 02No. (c) Pumping set 5HP - 02Nos. (d) Electric control panel - 02No Note item 01 to 02:- (a) Material such as cotton waste, dress i.e overall combination (navy blue colour), protective clothing, protective shoes, gas mask, gloves, water testing instruments and other instruments etc, as required for maintenance, manning and operation of plant shall be arranged by the contractor from his own sources for which cost of the same shall deemed to be included in the unit rate. No extra amount shall be paid separately on this account. (b) Installation shall be manned including Saturdays, Sunday & Holiday. (c) Proper log sheets for running of the pump house & plants to be maintained. (d) Testing of water sample during every water supply delivery time and recording test result in a register and to be get signed by Engr-in-charge. (e) Carry out weekly maintenance of electrical panels installed in pump house and intimate Engr-in-charge immediately for any defects/breakdown/repair required. (f) Carry out tightening of nuts bolts, replace when required, applying gland packing and greasing. (g) The contractor shall be responsible to keep the water supply installation neat and clean on every day. (h) All documentation such as log sheets, daily attendance register shall maintain as per procedure in vogue. (j) If the operator and valve man are found absent from duty, penal recovery shall be made per shift per head are as follows :- (i) Operator - @ Rs 2000 per operation shift per head. (ii) Valve man - @ Rs 1800/- per operation shift per head.
Manual rescue and operation rescue of water distribution sluice valves of various sizes etc with one valveman per shift, operation for 01 shifts/per day, (08 hours each shift) including Sundays and holidays including routine maintenance checks and upkeeping the installation and with the under laid components complete all as specified and as directed by the Engineer-in-charge. Location: 31 WEU Thane (a) Pumping set centrifugal type of capacity 12 litres/sec with 38 m head with electrically driven induction motor 15HP, 3 phase- 02 No. (b) Chemical dozing plant with injection assembly booster pump with induction motor of 1.5HP, 3 phase - 01 No. (c) Vertical type pressure filter of capacity 1000 glns/hr including blower unit with induction motor 5HP, 3 phase - 01No (d) LT electric control panel with all accessories and components - 02 Nos Note : (a) In case any operator is missing or absent from duty, a penalty of Rs 650/- per shift shall be recovered from any of dues of the contractor and the Engr-in-Charge decision shall be final and binding on this account. (b) The operator shall keep the paints, machineries and valve chamber surrounding area clean and tidy. (c) Contractor shall provide uniform and necessary tools required by the men employed by him. (d) Contractor shall submit the details of payments and wages for staffs employed through Aadhar link bank account Nos for payment purpose. (e) Painting of the equipments of pumps as required and existing to be done once in a year as per the directions given by the Engineer in Charge.
Mannual Rescue and Operation Rescue of water supply installation with all connected equipments, electric driven pump set, 10,000 Gph, supply lines and machineries (as listed herein under) and internal and external electrification, external water supply system, sumps, overhead reservoirs, service tanks, etc with one operator / technician operation for 02 shifts/per day, (08 hours each shift) including Sundays and holidays including routine maintenance checks and upkeeping the installation and with the under laid components complete all as specified and as directed by the Engineer-in-charge. Location: Thane (a) Pumping set centrifugal type of capacity 12 litres/sec with 38 m head with electrically driven induction motor 15HP, 3 phase- 02 No. (b) Chemical dozing plant with injection assembly booster pump with induction motor of 1.5HP, 3 phase - 01 No. (c) Vertical type pressure filter of capacity 1000 glns/hr including blower unit with induction motor 5HP, 3 phase - 01No (d) LT electric control panel with all accessories and components - 02 Nos Notes : (a) In case any operator is missing or absent from duty, a penalty of Rs 650/- per shift shall be recovered from any of dues of the contractor and the Engr-in-Charge decision shall be final and binding on this account. (b) The operator shall keep the paints, machineries and valve chamber surrounding area clean and tidy. (c) Contractor shall provide uniform and necessary tools required by the men employed by him. (d) Contractor shall submit the details of payments and wages for staffs employed through Aadhar link bank account Nos for payment purpose. (e) Painting of the equipments of pumps as required and existing to be done once in a year as per the directions given by the Engineer in Charge.
Comprehensive repairs & maintenance to HOT cranes (2 Nos )having 1 Ton capacity with 10 metrs span located in Torpedo workshop to be carried out as under:- (a) Opening of the chain pulley block for location of faults and replacement of unserviceable parts as required at site including attending routine complaints of users to keep the chain pulley block operational through out the year (maximum break down period shall not exceed more than 24 hrs from the time of receipt of complaint) (b) Checking the alignment of the ISMB for free movement of mechanically operated trolley. (c) Repairs/ maintenance of mechanically operated trolley including replacement of worn out parts complete for smooth functioning of the crane. (d) Application of grease to components and chain as per the manufacturers instructions. (e) Load testing of the crane after every repairs as per the instructions of 'handling explosive devices/ ammunition. (f) Load testing as per SWL of crane capacity. Note: Load will be arranged by the department within the radius of 2 KM from the testing site. However shifting of the loads to testing site and back to the place by engaging suitable crane/transport with man power shall be the contractors responsibility and the quoted rate shall be deemed to include for the same.
All as per Item No 5.00 above but for 22 cranes of capacity 2 Ton, located in EKM workshop, APR 2, P-50 HTL, A to G structure Magazine NAD Trombay and P-75 to P-78.
All as per Item No. 5.00 above but for 6 cranes of capacity 3/3.5 Ton, located in EKM workshop at NAD Trombay and NSD T-66.
Comprehensive repairs & maintenance and repairs to 1 No of EOT crane having capacity 2 Tons with 8 meters span of 4 M lift located in WED Sonobouy workshop with the following repairs :- (a) Opening of gear box of LT/CT, crab for examination, replacement of worn out parts and tightening the loosened components, checking, locking systems and closing up including testing commissioning in whenever required in any number of times through out the year including load test after every repair as per the instruction by Engineer in Charge. The permissible break down period for repair shall not exceed 24 hr from the time of receipt of complaint. (b) Checking the alignment of the ISMB for free movement of mechanically operated trolley and replacement of the chain if required. (c) Repair/replacement of worn out/burned unserviceable electrical items as required at site. (d) Tightening the DSL conductors and replace the supports if found necessary. (e) Applying grease to the components whenever required and replacement of Gear oil as per manufacturers instructions. (f) Testing of the limit switches, breaks and settings as required and to be replaced whenever unserviceable for smooth functioning through out the year. (g) Load testing as per SWL of Crane capacity. (h) Painting of the 1 SMB/ equipments of HOT/EOT as required and existing to be done once in a year as per the directions given by the Engineer in Charge. NOTE :- Load will be arranged by the department within the radius of 2 Km from the testing site. However, shifting of the loads to testing site and back to the place by engaging suitable crane/transport with man power shall be the contractors responsibility and the quoted rate shall be deemed to include for the same.
All as per Item No.8.00 above but for 1 crane of capacity 2 Ton having 10 meter span of 4 meter lift located in WED TP Sonobouy.
All as per Item No.8.00 above but for 2 cranes of capacity 3/3.5 Ton having 11 meters span of 4 meter lift located in EKM Workshop and section 5 at NAD (T).
All as per Item No.8.00 above but for 1 crane of capacity 5 Ton having 11 meters span and 8 meters lift located in Shed No -16 and AK- 230 at WED mankhurd.
All as per Item No.8.00 above but for 1 crane of capacity 20 Ton having 12 meters span and 11 meters lift located in WED shed No-7.
Comrehensive preventive maintenance by technically qualified technician and rendering operationally 2 Nos EOT crane of 30 TON capacity at DSRV as mentioned below including assemblies inspection to maintenance of longitude travel/cross travel system assy and checking lubricating of gear system topping up of lubricant upto desired level, replacement of gasket, nut, bolts, washer, split pins for proper tightness and safety including replaement of worn out part such as slip rings, Rubber Buffer, checking of coupling unit travel track etc all other miscellaneous item & ensure safe operation of crane. Preventive maintenance of housing system assy comprising of inspection checking including topping up/ charging of lubricants & gasket inspection and checking of bracing, pulley, nut, dolys washer, split pins, bushes, hooks, checking of housing pulley and lubrication thereof inspection of hoisting rope for cut aberration etc & cleaning up all greasy/ clipping materials inspection servicing, setting and testing breaking limit system for its safe operation. Inspection, checking and setting out. Preventive maintenance of elecrical control system complete all as specified and directed by Engr-in-Charge. Notes: (a) Ispection checking decarbonising & tightning of electrical connection in total system includig replacment of thimbles etc. (b) Inspection & checking of fuses, setting & tightning the same as per their capacity. (c) Inspection & setting of voltage system including replacement of fused indicating lamp etc. (d) Spares for EOT crane will be measured and paid seperately. (e) Contractor will carry out comprehensive maintenance once in a month for 11 months and maintain the record of the same as per the performa of monthly maintenanc check. (f) Contractor ensure serviceability and safety of crane during his each visit by way of maintining job card duly signed by JE E/M. (g) The contractor will also send Technician on call basis in case of any fault. Fault to be rectified within 8 hrs of receipt of complaint failing which Rs. 500/- per day will be deducted till rectification of defect. Contd......
(h) Rates of all consumables such as lubricant, gear oil, nut bolt, split pins, bushes, gasket are deemed to be included in the rates. (j) The tenders are required to submit the intent of MoU from any one of the OEM's i.e, M/s Rockwell Hoisto Cranes Pvt Ltd, M/s Poineer Cranes, M/s Hercules Hoisto, M/s Turbo Fergusan (India) Pvt Ltd, M/s Dinesh Enterprises, M/s Cranex, M/s USCGC, M/s Garlik, M/s Morri, M/s Hindustan Livers, M/s Grip Engineers, M/s Meta feb, M/s JPSENT, M/s Joel Industries. (k) The maintenance & repair under this contract shall be done through MoU issued by any one of OEM e.i M/s Rockwell Hoisto Cranes Pvt Ltd, M/s Poineer Cranes, M/s Hercules Hoisto, M/s Turbo Fergusan (India) Pvt Ltd, M/s Dinesh Enterprises, M/s Cranex, M/s USCGC, M/s Garlik, M/s Morri, M/s Hindustan Livers, M/s Grip Engineers, M/s Meta feb, M/s JPSENT, M/s Joel Industries. (l) Note : Crane load test certification to be certified by Govt recognised/approved agency and rate shall be included in the quoted rate. Note : For item No 1 to 9 : Crane load test certification to be certified by Govt recognised/approved agency and rate shall be included in the quoted rate. Painting of the HOT/EOT as required and existing to be done once in a year as per the directions given by the Engineer in Charge.
Material and labour for load testing 2 Nos of EOT crane of 30 Ton having 29 Meters span and 12 Meters hook height lift located in DSRV including all necessary preparation of test such as collecting of load block and re-depositing in the existing location, binding work, welding and all related material which may be required on ground to complete the whole testing procedure ascomplete job for both cranes. Note : (a) Crane load Test certification to be conducted by recognised crane manufacturer/ govt approved testing agent and submit to this office. Rate for the same shall be inclusive in the quoted rate. (b) Arrangement of mobile lifting machines, man power and supervisory staff for the complete test as specification above shall be the complete test as specified above shall be the sole responsibility of the contractor and rate shall be included in the quoted rate. (c) Any damage which may take place due to mishandling of testing procedure, inefficient of supervisory staff etc shall be made good by the contractor. (d) Load Cell required at site during testing will be provided by the contractor and rate shall deem to be in the quoted rate. (e) Any item which is not mentioned here-in-before but technically required while conducting the test shall be incorporated by the contractor to enable to complete the test satisfactorily and rate of the same shall deemed to be included in the quoted rate. (f) Load base platform suitable to carry safety the load (i.e not less than 50 Ton capacity) with sling of required Nos, shackle etc duly certified of their capacity/strength shall be provided for conducting the load and rate of the same shall be included in the quoted rate.
Supply & fixing in repair Two way lever type Limit switch Two contect Type LS/2SH/2 in IP 54 enclosure complete all as specified and directed by Engr-in-charge
Supply & fixing in repair A.C Drive (VVVF) 22 KW/ 30 HP for C.T Type A1000, 400 V complete all as specified & directly by Engr-in-Charge
Supply & fixing in repair A.C Drive (VVVF) 22 KW/ 5 HP for C.T Type A1000, 400 V complete all as specified & directly by Engr-in-Charge
Supply & fixing in repair to Three Pole power contactor 32 Amp with Aux contect coil voltage 110 V AC complete all as specifed & directed by Engr-in-Charge
Supply & fixing in repair to Three Pole power contactor 45 Amp with Aux contect coil voltage 110 V AC complete all as specifed & directed by Engr-in-Charge
Supply & fixing in repair to Three Pole power contactor 80 Amp with Aux contect coil voltage 110 V AC complete all as specifed & directed by Engr-in-Charge
Supply & fixing in repair Rodio Remote Control suitable for existing crane complete all as specified and directed by Engr-in-Charge.
Supply & fixing in repair Rotary type limit switch in Dia cast alu. Housing IP 67 Normal action 1 N.O + 1 N.C complete all as specified and directed by Engr -in- Charge
M & L or rewinding of squirrel cage induction electric motor 3 pahse, 415 volts, crane duty of cap 30 HP CDF 60%, 740 rpm complete all as specified and direced by Engr-in-Charge.
M & L or rewinding of squirrel cage induction electric motor 3 pahse, 415 volts, crane duty of cap 5 HP CDF 60%, 740 rpm complete all as specified and direced by Engr-in-Charge.
Supply and fix in repair long travel bearing 2/3 TON capacity complete all as specified and directed by Engr-in-charge.
Supply and fix in repair cable Trolley suitable for existing crane complete all as specified and directed by Engr-in-charge.
Supply and fix in repair Flameproof thuster bearing and coil of existing crane complete all as specified and directed by Engr-in-charge.
Supply and fix in repair wheel chain 2/3 TON capacity complete all as specified and directed by engr-in-charge.
Dismantling and taking down the Trolley Gun Metal Gear Wheel 2 Nos and Plane wheel 2 Nos in repairs and replacing with new ones as per the existing.
Dismantling and taking down the Trolley Gun Metal non Gear Wheel 2 Nos and Plane wheel 2 Nos in repairs and replacing with new ones as per the existing.
Supply and fix in repairs Timer for Hoist resistance from EOT crane complete all as specified and directed by engr-in-charge
Supply and fix in repairs Bobin Insulated complete all as specified and directed by Engr-in-charge
Supply and fix in repairs floating shaft drive and provision of wheel pin spacers complete all as specified and directed by engr-in-charge
Supply and fix in repairs Electro Hydraulic thruster brake liner 300 mm dia, up to 62 Kgm suitable for existing brake system complete.
Supply and fix in repairs Electro Hydraulic thruster brake liner 150 mm dia, up to 9 Kgm suitable for existing brake system complete.
Supply and fix in repairs Hydraulic thruster break liner 200 mm Dia for hoist
Supply & replacement of Transformer oil suitable for hydralic thruster brake for EOT Crane including draining out old perished oil complete.
Supply in replacement of Gear Oil complete all as specified and directed.
Taking down old defective chain pulley block and providing new chain pulley block assembly of 1 Ton capacity all as per directed by Engr-in-Charge.
Taking down old defective chain pulley block and providing new chain pulley block assembly of 2 Ton capacity all as per directed by Engr-in-Charge.
Taking down old defective chain pulley block and providing new chain pulley block assembly of 3/3.5 Ton capacity all as per directed by Engr-in-Charge.
M & L for Plumber block with bearing including sleeve complete all as specified and directed by Engr-in-Charge.
Taking down the defective travelling flexible cable PVC insulated multistranded copper / Aluminium conductor of 4 Sqmm 4 Core and supply and fix new travelling flexible PVC insulated multistranded copper conductor 4 Sqmm 1100 volts grade. Make - Finolex / PLAZA / RAVICAB.
Supply and lay in repairs/ replacement XLPE 4.0 Core 16 Sqmm insulated and PVC armoured heavy duty 1100 volt grade electric LT UG cable with aluminium conductor of following sizes laid in trenches/along the wall/pole including making all connections complete as required at site and as directed by Engr-in-Charge.
Supply and lay in repairs/ replacement XLPE 4.0 Core 10 Sqmm insulated and PVC armoured heavy duty 1100 volt grade electric LT UG cable with aluminium conductor of following sizes laid in trenches/along the wall/pole including making all connections complete as required at site and as directed by Engr-in-Charge.
Excavation in trenches not exceeding 1.5M wide and not exceeding 1.5M in depth and getting out in soft/loose soil for laying of under ground cable all as specified and directed by the engineer-in-charge.
Returning filling in including spreading, leveling watering and well ramming in layer not exceeding 25 Cms all as specified and directed by the engineer-in-charge.
Removal of excavated surplus soil not exceeding 50 m and depositing where directed at al level not exceeding 1.5 m above the starting point all as specified and directed by the engineer-in-charge.
M&L for sand cushioning by spreading in trenches fine dry river sand by gently by punning down manually as in cable protection all as specified and as directed by EIC.
Supply and laying un-reinforced precast concrete cable cover class LV, type-I, flat size 250mm x 150mm x 40mm laid in trenches all as specified..
S& F in repair of Fuel level assembly complete all as specified and directed by Engineer-In-Charge.
M & L for servicing of Air compressor machine complete all as specified and directed by Engineer-In-Charge.
Supply only bleaching powder for treatment of water and other purposes etc complete all as specified and directed.
M&L for scraping/cleaning surface of pipe lines of size 40mm to 150mm size and preparation of entire surface and applying one coat of Synthetic enamel paint epoxy coated ( Sea green colour for suction and discharge pipe lines) including writing, marking in stencil all as directed.
M&L for scraping/cleaning surface of pumpset, and preparation of entire surface and applying two coat of Synthetic enamel paint epoxy coated ( grey colour and red colour for fan cowl) all as directed.
Supply and fixing Air filter compressor assembly complete in repair including taking down old u/s Air filter as per sample size all as directed by Engineer-In-Charge.
M & L for carrying out 'B' check of 600 KVA DG Set including of 'B' check kit consisting of the following under laid complete all as specified and as directed by the Engineer-In-Charge. (i) S & F Primary Fuel Filter - 01 Set (ii) S & F Secondary Fuel Filter - 01 Set (iii) S & F Oil Filter - 01 No. (iv) Complete cleaning of DG Set (v) Examination and rectification of engine RPM (vi) Monitoring of output and maintaining and adjusting speed governor (vii) Painting of DG sets with two coats of synthetc enamel paint of colour as directed by the Engineer-In-Charge. (viii) Engine oil as required shall be measured and paid separately).
All as per item No. 57 above but 320 KVA DG Set.
All as per item No. 57 above but 250 KVA DG Set.
All as per item No. 57 above but 200 KVA DG Set.
M & L for servicing to AMF panel of DG sets of any capaity including routine/ preventive maintenance checks for trouble free functioning as directed. Note :The rate Quoted deemed to be included all the minor spares such as screws, washers, clips., battery terminals and other spares will be measured and paid seperately under supply only items.
Supply only distilled water in sealed bottles of 1 litre capacity complete all as specifed.
Supply only multi-grade 20 W 40 engine oil for topping upto required levels complete all as specified and as directed by the Engineer-In-Charge.
Supply only coolent for engines for topping up to required levels complete all as specified and as directed by the Engineer-In-Charge.
M & L for dismantling fuel tank of 250 KVA DG Set and draining out fuel in tank, cleaning the tank using pressure jet process, de-scaling the tank completely and refixing the tank in original position and refilling the tank with fuel retrieved on duly calibrating the same through authorised agencies of the manufacture (of DG Sets) complete all as specified and directed by the engineer - in - charge.
Supply and fixing in repairs fan belts including replacement of u/s fan belts for 125 to 320 KVA DG Set as per sample size all as directed.
Supply and fixing in repairs Residential Silencer including replacement of U/S Silencer for 250 KVA DG Set as per sample size all as directed.
S&F in repairs relay 12 V DC. suitable for existing AMF panel of suitable capacity.
Supply and fix in replacement battery heavy duty 12 Volts 180 AH maintenance free including taking down old u/s complete.
Supply and fix in replacement battery heavy duty 12 Volts 130 AH maintenance free including taking down old u/s complete.
Supply and Fix in repairs Change Over FP 250 Amps 415 Volt IN SHEET STEEL ENCLOSURE in open construction, panel mounted type with base plate for mounting in panel, including taking down of old Change over and reconnecting the cabes with proper glands.Make: Indo Asian /ABB/Havells/ Standerd
Supply and fix in repairs Fuel Injector Calibration for Fuel pump DG Set of any capacity complete all as specifed and as directed by the Engineer-In-Charge.
Supply and fix in repairs Power Capacitors of Rating 25 KVAR 415 Volt in repairs Naturally air cooled Double dielectric heavy duty, MPP type 440 Volt 50 HZ Watt Less Power Capacitors wattage not more than 0.5 Watt per KVAR conforming to IS 13340 and 13341 ISI Marked all as specified.
All as per item No. 73 above but Power Capacitors of Rating 20 KVAR 415 Volt
All as per item No. 73 above but Power Capacitors of Rating 15 KVAR 415 Volt
All as per item No. 73 above but Power Capacitors of Rating 10 KVAR 415 Volt
All as per item No. 73 above but Power Capacitors of Rating 7.5 KVAR 415 Volt
All as per item No. 73 above but Power Capacitors of Rating 5 KVAR 415 Volt
All as per item No. 73 above but Power Capacitors of Rating 2 KVAR 415 Volt
Supply and fix in repairs power factor controller relay 8 Stage RPM 8, 415 volts, 50 cycles suitable for manual / automatic operation with indication for each stage, power factor adjustment setting knob / screw, display.
M & L for testing of APFC panel for proper functioning in manual & auto mode, including re-wiring the burnt out wires, replacing the wiring ducts/casing Capping, fuse units and cleaning and testing complete all as specified and directed.
Supply and Fix in replacement of Contactor Three Pole 415 volts 25 Amps AC 3 Rating including add on Blocks suitable for driving POWER Capacitors, including making addition/Alternation to existing Wiring/circuit system
All as per item No. 82 above but Contactor Three Pole 415 volts 40 Amps AC 3 RatingConforming to Type - MNX - 40 & Cat no - CS94190 of L & T or equivalent.
All as per item No. 82 above but Contactor Three Pole 415 volts 70 Amps AC 3 Rating Conforming to Type - MNX - 70 & Cat no - ST19002 of L & T or equivalent.
M & L for dismantling carefullly fly wheel ring of 250 KVA DG Set and supply and fix new wheel ring to match the grooves of starter of existing model complete and testig for satisfactorily functioning.
S & F in replacement solenoid switch for control of fuel governor, operation in 12 Volts DC supply as per existing model fixed complete all as specified and as directed by the Engineer-In-Charge.
M & L for dismantling fuel level indicator pipe and supply and fix new PVC heavy duty white transparent pipe to botton and top fuel level knob and mark the levels of fuel tank including two nos. jublee clips of suitable size all as specified and as directed by Engineer-In-Charge.
M & L for servicing Fuel injection pump of 200/ 250 KVA DG Set by striping off complete and cleaning each part in volatile liquid cleaner / petrol removing scales, cleaning, injector, spray nozzle including replacement of wornout parts such as injector heads including re-calibration from authorised service centre for smooth functioning etc. including testing and refixing in the same position all as specified and as directed by Engineer-In-Charge.
M&L for dismantling existing unserviceable radiator and carrying out repair by draining out water/coolant,carring out pressure test and rectifying leakage by brezing/soldering test and reinstalling including filling fresh coolant (approx 60 ltrs) all as directed and specified for 250 Kva DG set
M&L for dismantling existing unserviceable exhaust pipe of 200KVA/ 320KVA/ /250 KVA DG set and supply and fix new exhaust pipe of exiting model complete including lapping asbestos rope making good all disturbed surface area to match the surrounding
S & F in repair to Generator controller panel display meter for 200 KVA DG Set as per existing make all as directed.
S&F Battery Charger 230 V, AC Input and 24 Volt DC out put suitable for AMF panel as per exising make complete all as specified and directed by Engineer-In-Charge.
S & F new movable battery charger for battery charging purpose of the DG Set as a back up in case of any failure to the panel for the uninterrupted DG supply all as specified and as directed by Engineer-In-Charge.
S & F in replacement of Power contactor current rating 200A fixed complete all as specified and as directed by the Engineer-In-Charge.
M&L for Spray painting of canopy of DG set of size from 200 to 315 KVA from outside with good quality enamel paint including cleaning with suitable cleaning agent, rubbing with emery paper, finishing, filling with putty for smoothness complete all as specified and directed.
Supply and Fix in repairs 230 Volts push buttons complete of colour red/ green with NO/NC elements including taking down old u/s complete.
S & F in repairs 230 Volts indication lamp complete(R Y B ) for mounting on LT panel including taking down old u/s complete.
M & L spray painting inside, outside complete to the LT panel boards outdoor type of size not exceeding 2.0 Mtr width 2.5 mtr in height and 0.75 mtr in depth with single coat of synthetic enameled paint of superior quality and approved colour after preparation of steel surface.
S&F cast iron covers, circular, for overhead PVC / RCC water storage tanks of any size, with MS strip / flat iron framework, with all necessary fixing and locking arrangements, nuts, bolts, washers, all as per BMC standards, with a shop coat of primer, including all necessary scaffolding / staging as required to cater at heights, taking out and disposing off old PVC covers, making any required addition / alteration to the tank for fixing of new CI covers, etc. complete all as specified, as directed by the Engineer-in-charge. (weight of tank cover not less than 10 KG). Make : As per sample
Dismantling unserviceable chemical dosing pump and replace with capacity of flow 10 LPM at max 5 Kg/cml pressure, 240 V, 50 Hz, complete with suction straner, pipe and dosing pipe including testing complete all as specified and directed. Make : Declibac Technologies pvt Ltd / Raclod / Milton Roy
Supply, fixing, jointing and testing of 80 mm, CI Sluice Valve heavy duty PN 1.6 with iron wheel head jointing, coupling both ends for cast iron pipes including nuts, bolts, rubber gaskets etc including taking down old unserviceable sluice valves complete all as specified and directed.
All as per item No. 102 above but 100 mm bore
S & F foot valve of size 80mm dia cast iron body, ball type, with flanged and drilled ends and synthetic rubber coated MS ball, conformimg to relevant IS, ISI marked, including all joints, gaskets, bolts and nuts, washers, including taking up/down old unserviceable valves from any position and any addition/alteration for fixing required complete all as specified and directed by the engineer in charge.
M & L for dismantiling the existing valve chamber of size 900 X 900 X 900 mm including necessary earth work in any type of soil, PCC foundation D-2 1:3:6 in base concrete, brick work in CM 1:6 with 10 mm thick plaster internally and 15 mm thick externally in CM 1:4, 6 mm thick MS cover with hinges and locking arrangement fixed to angle iron frame made-out of 40 X 40 X 6 mm MS angles complete with 2 coats of synthetic enamel paint over one coat of red oxide zinc chrome primer on all metal works including necessary excavation earth work all plastered surfaces of valve chambers complete all as specified and directed by Engr-in-Charge.
S & F in repairs float ball valve assembly 20 mm bore , high pressure grade, with polythene float, fly nuts, screwed to GI pipe or brass ferrule, CI fittings viz. nipples, check nuts, reducers, elbow, sockets, etc. fixed complete all as specified and as directed by the Engineer-in-charge for the following bores of pipes:
All as per item No. 106 above but 25 mm bore
All as per item No. 106 above but 40 mm bore
All as per item No. 106 above but 50 mm bore
M & L for servicing of Centrifugal pump set upto 20 HP by taking to workshop and opening end covers, greasing the bearings, replacing worn out nut, bolts, gasket, air release valve key, gland stuffing box male/ female set, Rubber bush and painting one coat of synthetic enamel paint, including writing/marking in 1" size letters SM & MES No and reinstalling in existing foundation complete with testing all as specified and directed by Engr-in-Charge. Note :- (i) Parts if required for pump shall be measured and paid separately here-in-after under another item as 'supply only.
All as per item No. 110 above but Pump set 5 HP
Supply and adding Calcium hypo chlorite 65% -70% chlorine content granular based water disinfectent in sealed containers complete all as specified and as directed.Brands having pan india availability, acceptability & being manufactured /processed in open market termed as traditional products .The brands /makes must have certified by All India Institute of Hygenic & Public Health. Note-: The chemical shall be brought in three lot and period to be procured only before previous batch completed.
Material and labour for taking out unserviceable burnt out electric monoblock/centrifugal motor with pump from the foundation of pump capacity 25 HP, 440 Volts, 50 Hz by opening/diconnecting all mechanical and electrical connection and transporting to nearest work shop and rewinding the same by using approved make super enamelled insulation copper wire of suitable insulation class of approriate size after pulling out burnt out copper wires from the sloths of stator including replacement of minor accessories like mica paper, sleeves, glass fibre, bamboo pieces etc inlcuding varnishing/heating at heat chamber suitably and opening the monoblock pump assy for replacement of unserviceable parts maintaince and reassembling all as per existing complete and taking back the whole pump sets to its original location and fixed or placed suitabley including making the electrical and pipe connection including testing to get satisfactory result complete all as specified and as directed. Note: (i) Parts if required for pump shall be measured and paid separately here-in-after under another item as 'supply only.
M&L for chemical potability test for water before and after cleaning / desiliting waterby authorised chemical laboratory ,BMC approved. Test result to be submitted in duplicate all as specified and directed
M& L for attending day to day complaint of minor nature including replacement of fittings such as elbow,socket,tee etc and deposting the complaint slip in complaint cell after user signature complete as per directed by engineer in charge.
M & L in replacement of PVC Service Water Tank including tank nipple, bends, sockets complete all fitting required at site all including taking down the existing tanks as specified and directed by Engineer-in-Charge of 500 Ltrs capacity.
All as per item No. 116 above but 1000 Ltrs capacity.
All as per item No. 116 above but 2000 Ltrs capacity.
Taking up or down steel water tubing of upto 50 mm bore and connections including cleaning and setting a side for refixing, etc complete all as specified and directed by the engineer-in-charge.
Supplying, laying, connecting and testing of GI tubing med gde of 25 mm dia with and including all fittings such as bends elbows, tees, short pieces, connectors, check nuts, diminishing pieces, caps and plugs, unions,etc fixed complete laid in trenches / along the walls / ceilings / floors / ducts / on pillar post all as specified and directed by Engineer-in-charge.
All as per item No. 120 above but 40 mm dia.
All as per item No. 120 above but 50 mm dia.
All as per item No. 120 above but 80 mm dia.
All as per item No. 120 above but 100 mm dia.
M&L for dismantling overhauling ,packing and refixing of 5 HP, 3 Phase motor after opening carefully and stripping all parts cleaning removing defective burnt winding . Rewinding the motor with super enamelled copper conductor of the existing guage and number of turns as per the original winding pattern of the manufacturer varnishing with quick dry varnish drying it properly oiling and greasing of moving parts ,assembling , reinstalling testing on completion all as directed
Material and labour for carrying out vaccum test, pressure test and detecting leakage rectifying the leak and charging the refrigerant (R-22) complete for Tower/split/window type A/C of any capacity Note : (i) Job includes dismentling equipment from any site, height and transporting to workshop if necessary and reinstalled in situ and testing (ii) Above Job to be guaranteed for minimum one year
All as per item No. 126 above but for water cooler of any capacity
All as per item No. 126 above but suitable for refrigertor/ deep freezer of any capacity
M & L for repairs to base/body/stand of water cooler of any capacity by cutting out rusted portion, replacing with new M.S sheet of existing gauge including finishing wall surface and painting complete body of water cooler of any capacity Noe :- Job includes dismantling equipment transporting to workshop and back included' re-installing in situ.
Supply and fix in repairs chasis made out of 2mm thick MS sheet suitable for 1.5 TR/ 2.0 TR capacity window type AC including dismantling accessories and re-installing on new chasis, painting complete body and required parts incld connection with new wiring etc all as directed
Material and labour for servicing of A/C window type or split type A/C, tower AC of capacity 1.5/2/2.5 TR including washing with sodash the cooling coil/condensor coil base body drying with air blower checking complete wiring testing and re-installing in situ and testing the unit.
M & L for dismentling unserviceable compressor from the window type AC, Split type A/C 1.5 TR/ 2.0 TR capacity from any location, supply and fix new hermatically sealed compressor unit , assembling, brazing pressure/vaccum testing initial oil charging, gas charging,reinstalling A/C in situ and connecting to electric supply and testing all as directed and specified. Make : Voltas/Carrier/Kirloskar /bluestar Note : (i) Job including removing A/C from any site/height/location (ii) Transporting A/C unit to repair workshop and back to site (iii) Loading/unloading etc
All as per item No. 132 above but suitable for refrigerator 165 to 320 ltrs capacity
All as per item No. 132 above but suitable for water cooler 40 t0 150 ltrs capacity
All as per item No. 132 above but suitable for deep freezer of 200 to 500 ltrs capacity
Supply and fix in repair AC fan motor for window/split type A/C of 1.5/2 TR ,Tower AC 2.5 TRcapacity single phase 230 volt 50 HZ complete with fan blade/blower including any addition/alteration to suit new fitting of motor.
All as per item No. 136 above but for Water cooler any capacity
All as per item No. 136 above but for deep freezer any capacity
Supply and fix in repair Relay for A/C split/window type,Tower AC
Supply and fix in repair Relay for WATER COOLER/DEEP FREEZER
Supply and fix in repair Thermostat for A/C 1.5 TR/2 TR,Tower AC
All as per item No. 141 above but for water cooler of any capacity
Supply and fix in repair Air filtter for window type/split type AC, Tower AC as per sample
Supply and fix in repair Starting capacitor 80-100 mfd 220 volt 50 HZ
Supply and fix Starting capacitor of capacity 120 - 150 MFD for 2 TR, 2.5 TR capacity
Supply and fixing in repair of Running capacitors of capacity 45 MFD 220 volt 50Hz complete all as specified and directed by Engr-in-Charge
All as per item No. 146 above but 36 MFD
All as per item No. 146 above but 6 MFD
All as per item No. 146 above but 4 MFD
Supply and fix in repair 3 core 4 sqmm flexible cable PVC insulated sheathed copper 1100 volts grade.
Supply and fix in repair 3 core 2.5 sqmm flexible cable PVC insulated sheathed copper 1100 volts grade.
Supply and fix in repair earthed metal clad socket outlet with earthed plug top 20 Amps capacity with sheet metal enclosure and one 20 Amps MCB SP all as specified and directed.
M & L for power point wiring with PVC insulated sheathed copper wire 4 Sqmm size 1100 volts grade IS-654 in and including PVC casing and capping with all accessories including one run of 2.5 Sqm earth lead wire all as directed and specified.
Supply and fix in repair copper tube of size 6mm bore including brazing etc with rubberised insulation and tape suitable for supply pipes for air-conditioners complete all specified by Engineer -in-charge
Supply and fix in repair copper tube of size 10 mm bore including brazing etc with rubberised insulation and tape suitable for supply pipes for air-conditioners complete all specified by Engineer -in-charge.
Supply and fix in repairs 8mm dia hand shut off valve
Supply and fixing in repair and testing fan blade of motor for water cooler of 80/100/120/150 Ltrs capacity including removing old fan blade.
Supply and fixing in repair and testing fan blade suitable for window type Air conditioner of 1.5 Ton/2 Ton capacity including removing old fan blade.
Supply and fix in repairs front grill as per sample suitable for window type AC 1.5 TR/2 TR capacity.
Supply and fixing in repair of blower drum suitable for window type Air concitioner of capacity 1.5Ton /2TON.
Supply and fix in repair stainless steel tank of capacity 40 ltrs capacity water cooler of existing size shape
All as per item No. 161 above but 80 ltrs capacity
All as per item No. 161 above but 120 ltrs capacity
Supply and fix in repair waste water tray suitable for single/double tap with waste hose.
Supply and fix in repair PVC float valve wih PVC ball suitable for 15mm dia
Supply and fix in repairs bibtap push type stainless steel 15mm dia
Supply and fix in repairs gun metal gate valve with iron wheel head screwed both ends for iron pipe of size 20mm.
Supply and fix in repairs gun metal gate valve with iron wheel head screwed both ends for iron pipe of size 15mm.
Supply and fix in repairs remote sensor kit with Manual control pendent suitable for split type A/C,Tower AC 1.5 TR to 2.5 TR capacity work on 230 volt SP 50 HZ
Supply and fix base tray suitable A/C 1.5/2 TR made out of 2mm thick of existing size and shape including painting one coat zine chrome red oxide and two coats of synthetic enamelled paint
Supply and fix in repairs ventury and blower drum suitable for A/C window type 1.5 TR/2 TR as per existing model, size, and shape
Supply and fix in repairs condensor coils suitable for 1.5 TR to 2.5 TR capacity including dismentling old one brazing, testing, leakage rectification all as directed.
Supply and fix in repairs cooling coil suitable for 1.5 TR to 2.5 TR A/C of existing model including taking out old defective coil, brazing work, brass charging to full pressure
Supply and fix in repairs thermal over load relay 415 volts 66 - 110 Amps rating MMX R-4 model
Supply and fix in repairs thermal over load relay 415 volts 32 - 50 Amps rating MMX R-4 model
M&L in repair for wall mounted powder coated MS bracket suitable for 1.5TR/2TR Split type AC, Towre AC 2.5 TR out door unit
M&L for repair of rubberised insulation and tape for copper tubes of size 6mm/10mm.
M&L in repair sub main wiring with two single core PVC-FRLS insulated unsheathed multistranded copper conductor cable of size 4 sqmm drawn in PVC casing caping with 4 Sqmm PVC-FRLS insulated unsheathed multistranded copper conductor as a continuous earth wire complete all as specified. Note : (i) Two single core cable one run of earth copper conductor & one run of PVC casing & caping will be measured and paid as one unit length.
Supply and fix in repair of Cable junction box IP 66/69 "weather proof" (with knockouts for cable entry) box of size 155 x 210 x 92 mm with connector/terminal, Din Rail, GI clamps made out of GI flat of size 25 mm X 3 mm channel including providing detachable GI 3 mm thick plate inside looping box as cable gland plate and including cable glands as required at size and making connections all as specified and directed by Engineer –in –Charge. Make - Hensel/ National/ Sintex
Supply and fix in repair of Cable junction box IP 66/69 "weather proof" (with knockouts for cable entry) box of size 130 x 180 x 77 mm with connector/terminal, Din Rail, GI clamps made out of GI flat of size 25 mm X 3 mm channel including providing detachable GI 3 mm thick plate inside looping box as cable gland plate and including cable glands as required at size and making connections all as specified and directed by Engineer –in –Charge. Make - Hensel/ National/ Sintex
S& F in replacement of GI steel tubing medium grade 40 mm dia for laying in ground, along the pole in coping, road crossing etc for cabe protection including necessary fittings , clamps for supports, etc all as directed by Engineer in charge.
S& F in replacement of GI steel tubing medium grade 80 mm dia for laying in ground, along the pole in coping, road crossing etc for cabe protection including necessary fittings , clamps for supports, etc all as directed by Engineer in charge.
M & L for taking down of 400 Amp ATS having two incoming and one outgoing, including opening the cable ends and disconnecting the incoming and outgoing cables and removing the ATS, clening and servicing and reinstalling the ATS after carry out necessary repairs to the ATS main controler, PCB Card, cleaning and earthing all parts and reconnecting the cables all as specified and directed by the Engineer-in-charge.
Supply & Fix 9 watts LED Bollard Garden light fittings with efficient high output LED, Pressure die cast powder coated housing with PC diffuser , driver nuts, bolt, washers, base plate, foundation 0.3 Meter x 0.3 Meter x 0.3Meter by PCC 1:2:4 type B-1 using 20 mm graded stone aggregates of size including excavation and earthwork, provision of pvc of size 40 mm dia in the PCC for cable entry, etc all as directed by Engineer in charge. Make :- Bajaj/Crompton/Havells
Supply and fix in replacement of Rectangular LED Flood Light 350 Watt with innovative thermal management, multiple optics and equipped with IP66 protectionflood light fittings including drivers, pressure die cast aluminium housing, prewired complete. Make - Jaquar/ Crompton/ Havells/ Bajaj
Supply and fixing post top lantern LED type 40 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection die cast aluminium spigot with spun aluminium top duly powder with PC diffuser & PMMA clear diffuser from outside with impact and corrosion resistant complete with driver and lamp complete. Make - Havells/ Crompton /Bajaj
Supply and fixing post top lantern LED type 20 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection die cast aluminium spigot with spun aluminium top duly powder with PC diffuser & PMMA clear diffuser from outside with impact and corrosion resistant complete with driver and lamp complete. Make - Havells/ Crompton /Bajaj
S & F in repair/replacement of LED Driver 60 Watt Suitable for street light fitting complete all as specified and directed.
S & F in repair/replacement of LED Driver 30/35 Watts Suitable for street light fitting complete all as specified and directed.
Supply and fixing in replacement of MCCB 400 Amps 36 KA, 3 Pole including lugs,nut, bolts. washers etc and dismentling of old MCCB testing complete all as specified and directed by Engineer-in-Charge. Make : Havells/L&T/Legrand/Schneider
All as per item No. 190 above but MCCB 250 Amps 36 KA, 3 Pole complete all as specified and directed. Make : Havells/L&T/Legrand/Schneider
All as per item No. 190 above but MCCB 200 Amps 25 KA, 3 Pole complete all as specified and directed. Make - Havells/L&T/Legrand/Schneider
All as per item No. 190 above but MCCB 100 Amps 2 KA, 3 Pole complete all as specified and directed. Make - Havells/L&T/Legrand/Schneider
M&L for locating of faults of LT UG cable XLPE upto 400 sqmm sized by using computerised/ primary current inection method including cutting and removing the faulty portion of the cable and jointing with suitable cable joint and testing after jointing all as required and directed at site. Note: (i) Excavation,earth work,sand cushing, PCC cover etc will be measured and paid seperately. (ii) Cable joint will be measured and paid seperetely. (iii) Additional lenth of cable required at site for jointing will be measured and paid seperately.
M&L for straight through joint (HEAT SHRINKABLE TYPE KITS) for underground cable including joint kits and labour complete for making joints suitable for LT, XLPE/PILCA/PVC sheathed armoured heavy duty cable with aluminium conductor 3.5/4 core 6 to 16 Sqmm complete with testing till satisfaction of Engr-in-Charge.
All as per item No. 195 above but 2/4 core 25 to 50 Sqmm size -do- complete all as specified and directed.
All as per item No. 195 above but 3.5/4 core 70 to 120 Sqmm size -do- complete all as specified and directed.
All as per item No. 195 above but 3.5/4 core 120 to 185 Sqmm size -do- complete all as specified and directed.
M&L for preparation of old painted surfaces of pre-stressed concrete pole upto 11/9 mtr long by scarping old paint and applying two coats of cement base paint including numbering of pole with black oil paint painting the base of the pole in alternate black and yellow stripes each 30 Cm apart up to 1.5mtr height including marking of MES No with black paint on the pole all as directed by Engineer in Charge.
M&L for preparation of old painted surfaces of Steel Tubular pole upto 9 mtr long by scarping old paint and applying two coats of Aluminium paint including numbering of pole with black oil paint and painting the base of the pole in alternate black and yellow stripes each 30 Cm apart up to 1.5mtr height including marking of MES No with black paint on the pole all as directed by Engineer in Charge.
Dismantling and taking down the existing defective street light fitting/Garden lights/Building security light of any type and any capacity from steel tubular pole, opening the street light fitting, checking the serviceability of spare parts including replacement of defective parts such as electric drivers and connectors after repairing including refixing on pole including connecting & testing complete all as directed by Engr-in-Charge. [Note:- Electronic drivers and LED will be measured and paid separately].
M&L in repairs of Earthing complete with M.S. galvanized earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit not less than 2.25 M deep below normal GL) with top edge of the plate not less than 2.50 M below normal GL, connected to Galvanized earth strip 32x6mm upto 7.5 mtr with protection pipe by means of bolts, nuts, check nuts & washers of GI or steel incl excavation, PCC (1:3:6) type C-1 chamber with RCC cover (1:2:4) type B0, 40 mm thick reinforced with 6 mm dia bar, 3 Nos. both way, 40mm dia light grade GI protection pipe, funnel with wire mesh,watering pipe of size 20 mm dia med. grade, lugs, main Earthing lead upto 7.5 mtr incl. Charcoal dust, salt etc. all as shown in electrical plate No. 3 of SSR Pt-I 2009 specification.
S&F in repairs GI strip size 32 x 6 mm all as directed including welding brazing and taking down of old strips as required at site
M & L spray painting inside, outside complete to the LT panel boards outdoor type of size not exceeding 2.0 Mtr width 2.5 mtr in height and 0.75 mtr in depth with single coat of synthetic enameled paint of superior quality and approved colour after preparation of steel surface.
M&L in repairs for 24 Hrs 240 V FM1 Quartz type Time switches astronomical type (Having longitude and latitude of Indian cities in memory) timer for controlling street lights contactors complete all as directed by Engr-in - Charge .Make :-Legrand/ L&T/Indo Asian as approved by GE
Supply and fixing LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed.
Supply& fixing in repairs of Chequered plate Fe 410-W(Gde-E- 250)A quality- for cable trenches, ladders including equal angle trench frames, including cutting as per requirement of site, square cut or notched (ordinary and counter sunk) forming holes, without any including providing handles
Supply& fixing in repairs for mild steel work confirming to Fe-290, GdeE-165 in stairs/ladders including stringes, treades, landing, balusters, hand rails etc including applying two coat of paint over one coat of red oxide complete all as specified and directed.
M&L for reinforced cement concrete nominal mix M-20 (using 20mm graded stone aggregate) for foundations, including rafts, footings, foundation beams, plinth beams, bases for column etc and mass concrete, complete all as specified and directed. (Note - Reinforcement and form work will be measured and paid separately).
Dismantling old PCC Pole/ Steel Pole and Supply, Fixing and connection of hot dip galvanised octagonal poles of height 6 mtr with 130mm bottom A/F & 70mm top A/F made up of 3mm thick HT sheet along with base plate of size 200 x 200 x 12mm thick including 4 nos of M20 x 600 long J type foundation bolts and 1 mtr long hot dip galvanised single arm standard bracket, including MCB of 6 Amps, with connector 4 way to be provided as termination point complete all as specified and directed.
M & L for servicing of Centrifugal pump set of capacity 25 HP by opening end covers, greasing the bearings, replacing worn out nut, bolts, gasket, air release valve key, gland stuffing box male/ female set, Rubber bush and painting one coat of synthetic enamel paint, including writing/marking in 1" size letters SM & MES No. for the following capacity of pumps:-
All as per Item No 211.00 above but Pump set 20 HP
All as per Item No 211.00 above but Pump set 15 HP
All as per Item No 211.00 above but Pump set 10 HP
All as per Item No 211.00 above but Pump set 5HP
Supply and fix in replacement of old unserviceable Cast iron tank cover with MS strip /flat iron framework with all necessary fixing and locking arrangement nuts,bolts all as per BMC standards any required alteration to the tank for fixing of new CI covers all as specified and directed by the Engineer -in-Chief of sizes:- 508mm dia. (weight of tank cover not less than 12 Kgs)
M&L for rewinding of electric motor 25 HP 3 phase 50 Hz 415 volt of following capacities complete all as directed and specified as under: (a) Disconnecitng, dismantling existing burnt widning from motor and rewinding complete with super enamled copper winding wire of matching gauge including all insulation material such as PVC insulated sheet, cotton tape sleeves varnish etc. (b) Transporting electric motor including loading/ unloading upto wksp and back to site. (c) Re-installing the same at the orignal locaition with proper alignmenent connecting and testing on load. (d) Replacement 2 Nos ball bearing for each motor of existing size/model. Make- SKF/NBC/TATA. (e) Replacement of winding terminal plate with brass stus,/ nut, bolt washer. NOTE: Quoted rates shall be deemed to include one year warranty for motors after rewinding and commissioning.
All as per Item No 217.00 For Motor 20 HP Cap
All as per Item No 217.00 For Motor 15 HP Cap
All as per Item No 217.00 For Motor 10 HP Cap
All as per item No 217.00 for Motor 7.5/5 HP cap
S&F the following component in existing LT Panel Boards including disconnecting and taking down at different locations all as directed :- Voltmeter Digital type ,0-500 Volts of size 96x96mm.
All as per item No 14 but Ammeter Digital type of 400 amps capacity of size 96X96mm.
Phase indicating lamp neon type complete with holder assy RYB
CT coils any capacity.
Drilling and taping cast iron water mains (in position) for branch connections 15 mm bore of the internal dia.
All as per item No 227.00 above but 20mm bore
Taking up or down steel water tubing 15 mm bore and connections including cleaning for re-fixing or removal.
All as per item No 229.00 above but 20mm bore
All as per item No 229.00 above but 25mm bore
All as per item No 229.00 above but 40mm bore
All as per item No 229.00 above but 50mm bore
M & L for preparation of old painted / unpainted surfaces of any description, including taking out of parts / components under painting (if required) from any position / location as listed hereinunder and applying one coat of epoxy paint (with colour code maintained as per relevant IS) including marking with flow directions (of approved colour) complete al as specified and as directed by the Engineer-In-Charge. (a) Induction motors 25 HP/20 HP - 06 Nos. (b) Electric motors 10/7.5 HP - 03 No. (c) Sluice valve 100 mm dia. - 06 Nos. (d) Sluice valve 80 mm dia. - 06 Nos. (e) Electric Panel Board - 04 Nos
S & F foot valve of 150 mm bore, in cast iron body, ball type, with flanged and drilled ends and synthetic rubber coated MS ball, conformimg to relevant IS, ISI marked, including all joints, gaskets, bolts and nuts, washers, including taking up/down old unserviceable valves from any position and any addition/alteration for fixing required complete all as specified and directed by the engineer in charge.
M&L for dismantling existing unserviceable sluice valve and supply and fix new sluice valve ISI marked IS-14846 PN 1.6 with iron operating wheel, flanged type rubber gasket, nut, bolts, washers, including any addition alteration. Fixing of new sluice valve of size 100 mm bore.
Supply, lay/fix, connect and testing UPVC water tubing, 25 MM, with screwed and socketed joints, in any length, including supply and fixing all fittings, ISI marked and fixed to wall/ceiling or laid in trenches/floors including taking up/down existing tubinging and connections complete all as specified and directed by the Engineer-in-Charge.
S&F in repairs GM gate valve ISI marked IS-778 screwed down for iron pipe of size 50mm. Make;- Leader/Neeta/ Guru including any addition/alteration and fittings like union, check nut etc
All as per item No 238.00 above but of size 40mm dia.
All as per item No 238.00 above but of size 25mm dia.
M&L for cement concrete in foundation, filling and mass concrete (1:4:8) type D2 using 40mm graded stone aggregate
Taking down old unserviceable High bay, Mid Bay, Flame Proof light fittings from walls/Builings/Sheds/Ceiling height up to 10 Meter for repairs and replacement of burnt/worn out accessories and refixing the same in existing position including testing of fittings after repair, testing of connected wiring complete all as directed by Engineer in charge . Note :- (a) T & P, Ladder for any height etc are deemed to be included in the quoted rate. (iii) The representative of the contrcator shall report to Engineer-in-charge/JE and carry out repairs on daily basis during the contrcat period and the defect shall be rectified on the same day (iii) A penal recovery of Rs 500 Per Day Per Complaint for not attening the compalint will be recovered
Supply & fix in repairs LED Highbay light fittings 150 watts, Energy saving, environment friendly & robust open type vertical Highbay LED IP 66 luminaire including driver and required GI tube down road of length up to 2 meter with hoooks for hanging the fitting. The fitting including fixing arrangements and taking down old rusted bracket fittings complete etc. Make :-Crompton / Havells /Bajaj. Note : Fittings shall will be installed in Hangers/Sheds, height up to 10 Meters only and directed by Engr-in-Charge.
Supply & fix in repairs very high efficiency round LED Highbay light fittings 150 Watt in PDC housing, IP 66 luminaire including driver and required GI tube down road of length up to 2 meter with hoooks for hanging the fitting including fixing arrangements and taking down old rusted bracket fittings complete etc. The Make :-Crompton / Havells /Bajaj. Note : Fittings shall will be installed in Hangers/Sheds, hight up to 10 Meters only and directed by Engr-in-Charge.
Material and Labour for checking of panels, DB's, Junction Box, including cleaning with blower, clamping of lugs as per existing size and capacity complete all as specified and directed.Technician will Carry scheduled preventative maintenance checks as per details to be given by Site Executive.
S & F in repairs MCCB 63 Amps, 25 kA Triple Pole 415 Volts including connecting up complete in existing panel with suitable lugs/ Glands all as specified and directed. Make:- L&T/ Legrand/ Schnieder/ ABB
Taking down existing UG cable and supply & Lay XLPE insulated, heavy duty 1100 volt grade electric armoured LT UG cable with aluminium conductor of size 95 Sqmm 3.5 Core in trenches/along the wall/including making all connections, saddles, spacersincluding scaffolding if any required for saddling the cable in walls of building of height up to 25 meter, complete wih aluminium lugs as required at site and as directed by Engr-in-Charge
Supply and fixing 36 Watt All in one integrated Solar Street Light fitting with complete system with Battery Lithim ion, 11.1 V, 39.6 AH including braket and including taking down old unserviceable fitting with fixing assembly complete all as directed by Engineer in Charge. Make : Sai Indutrial alliances pvt ltd/ Crompton/ Bajaj as approved by GE
S&F in Surface, hanging and wall mounted batten CRCA housing box type luminaire (Double side connection) suitable for T8 LED tube 20/22 watts, 230 volts rated luminous flux 2400 lm/2280 lm, CCT 6500K, CRI >80, life span >50000 hrs alongwith LED tube with polycarbonate housing designed for high performance tube rod 22 watt (double side connection), including fixing mounting blocks 2 Nos, 15 mm MS conduit, 1.5 sqmm 3 core pvc insulated copper conductor cable including fixing arrangements complete all as specified and directed. Make- Bajaj Cat code no- BLRB/ 20W CW LED S (<10% THD) and BLRB- DB 218 or equivalent Jaquar/ Wipro
S&F in repairs Surface, hanging and wall mounted batten (Single side connection) suitable for LED tube 20/22 watts, 230 volts alongwith tube rod 22 watt (double side connection), including fixing mounting blocks 2 Nos, 15 mm MS conduit, 1.5 sqmm 3 core pvc insulated copper conductor cable including fixing arrangements complete all as specified and directed. Make :- BAJAJ/ PHILLIPS/ JAQUAR/ WIPRO
Supply & fix high speed Ceiling fans complete with aluminium blades, down rods, PVC Canopy and accessories white in color 230 V, 1200 mm sweep Min air delivery 210 CFM with service value min 6.00 BEE Five star rated with brushless direct current motor (BLDC) without remote complete. Make- Havell's (Efficiencia Neo (BLDC 26W)/ Orient (FALCON 400)/ Bajaj(ENERGOS 28))
Supply and fix heavy duty Metalic body Exhuast fan high speed type of sweep 300mm, speed 1400 RPM, air delivery 1300 CMH, power 70W comprising of double ball bearing,blades,louvers complete mounting anchor fasterners aluminium louvers made of aluminium sheet of 0.5 mm thickness provision of 3 core 1.5 sqmm copper cable from ceiling rose to fan etc complete all as specified and directed. Make- Crompton/ Orient/Almonard/Bajaj. Note-The Contractor shall submit 1 year warrenty ceertificate from OEM of exhaust fan.
Supply and fix heavy sturdy Engineering plastic Exhuast fan high speed type of sweep 250mm, speed 1400 RPM, air delivery 1300 CMH, power 70W comprising of double ball bearing,blades,louvers complete mounting anchor fasterners aluminium louvers made of aluminium sheet of 0.5 mm thickness provision of 3 core 1.5 sqmm copper cable from ceiling rose to fan etc complete all as specified and directed. Make- Crompton/ Orient/Almonard/Bajaj. Note-The Contractor shall submit 1 year warrenty ceertificate from OEM of exhaust fan
Supply & fix ceiling fan complaints 2.5 Mfd operating on 230V, 50 Hz AC supply IS :1709 marked complete. MAKE:- KELTRON/EPCOS/ CAPCO/ TISCON
M & L for point wiring complete with proper colour coding with 1100 Volts grade, 1.5 Sqmm PVC insulated FRLS grade, unsheathed, wire confirming to IS-694, Part II, ISI marked with multistranded copper conductor drawn in and including PVC concealed conduit of suitable size of wall/ RCC slab/ ceiling/ colunms/ beams etc with all accessories, fittings, PVC junction boxes etc, for mounting modular switches, sockets, fan regulators etc, also including 1.5 Sqmm, PVC insulated, FRLS unsheathed, 1100 Volts multistranded copper conductor green colour as contineous earth wire connected to common earth dolly for one light point/fan/bell point controlled by one way switch, complete all as specified and directed. Note : Rates included for concealed cutting as required at site without any damage and making good in CM 1:4 and matching the surface as required 2 all screws and washer for point wiring shall be Stainless steel. Nothing is extra shall be admisible on this account. Make of Conduit- Sudhakar/ Precision/ Pressfit. Make of copper wire- KEI/ Anchor (Panasonic)/ Polycab/ Finolex.
Supply and fix in replacement 8/9 Watt LED Bollard garden light fitting with efficient high output COB LED, pressue die cast powder coated housing with PC diffuser driver nut bolt ,washer base plate foundation 0.3 mtrx0.3 mtr x.40 mtr by PCC 1:2:4 type B-1 using 20mm grade stone aggegates of size including excavtion and earth work , provision of GI bend of size 50MM dia in the PCC for cable entry all as specified and directed in EIC. Make:- HAVELLS/ PHILLIPS/ JAQUAR/ WIPRO/BAJAJ.
Supply and fix New generation , Post-top LED warm light 35/40 W,energy saving, environmental friendly, long life aesthetically designed with symmetrical light distribution,spun aluminium landscape luminaire with high power LEDs as light provision of GI bend of size 40 mm dia in the PCC for cable entry the fitting with nut bolts,washer all as specified and directed in EIC. Make:- HAVELLS/ PHILLIPS/ JAQUAR/ WIPRO.
Supply & Fixing round shape 15 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete. Make : Bajaj/Crompton/Jaquar
Supply & Fix MCB DB Double Door SPN 4 way 240 volts including connecting up with existing cable with new lugs. The DB Shall be of Make - Havells/Indoasaian/Legrand/ABB/Schnider
Supply & Fix MCB DB Double Door SPN 8 way 240 volts including connecting up with existing cable with new lugs. The DB Shall be of Make - Havells/Indoasaian/Legrand/ABB/Schnider.
S & F in repairs electronic fan regulator five stepped, operating on 230V, 50 Hz AC supply, duly IS :1979. Make:- Anchor/ legrand/ Vinay
Supply and fix electronic meters temper proof LCD display with polycarbonate cover 230 V, 10- 60Amp, accuracy class-I 50Hz, conforming to IS 13779, IP-54, with parameters to show data, time,current reading, load, PF, voltage and KWH Make:- L&T/ IndoAsian
Supply of Lithium Based Integrated Solar in FRP body all in one integrated solar street light 16 Watt white LED type with IP 66 or better ingress protection with inbuilt lithium Battery 11.1V/12.8Volt 19.8Ah, provided with 2 LED indicators a green light to indicate charging in progress and a red LED to indicate deep discharge condition of the battery,green LED glow only when the battery is actually being charged,battery included in the luminary enclosure, with water proof (IP 66 ro better) and corrosion resistant, material of construction of solar light fitting shall be FRP,LED lamp 16 watt (W-LED, 180-200 lm/watt, CRI>70) with 120 Degree vide angle lens fo better light distribution and colour temp-5700-6500K, solar PV module mono crystalline,> 35Wp
cooltech engineering services (BID ID -3168781)
Darpan Construction (BID ID -3168079)
shakti engineering and electrical works (BID ID -3168853)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .