Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance NO 68 ANJANEYA TEMPLE CROSS OPP M S RAMAIAH HOSPITAL NEW BEL ROAD BANGALORE 560 094 | BENGALURU URBAN | KARNATAKA | 560094 | Admitted-Finance |
| 3 | Admitted-Finance 606 80 FEET ROAD 7TH BLOCK 2ND PHASE BANASHANKARI 3RD STAGE BANGALORE 560 085 | BENGALURU URBAN | KARNATAKA | 560085 | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹27,000
Closing Date
11 Mar 2021, 6:00 pmClosed
Shri Vineet Modi
CWE AF North Bangalore Bellary Road JC Nagar Post Bangalore 560006
REPAIRS/MAINTENANCE OF DG SETS, AMF PANELS, CABLES INCLUDING PAINTINGS AND OTHER CONNECTED WORKS AT HQTC BANGALORE
2021_MES_418541_1
87414CWEAFNBAN
Open Tender
Miscellaneous Works
Item Rate
330 days
GE AF BANGALORE
AS PER NIT
5 documents required · 5 mandatory
₹500
GE AF BANGALORE
₹27,000
Yes
15 Mar 2021
3 Feb 2021
13 Mar 2021
3 Feb 2021
11 Mar 2021
28 Feb 2021
4 Feb 2021 - 13 Feb 2021
Amount
Material & Labour for supply, carrying out B check maintenance of DG set including the replacement of fuel filters, lub oil filters, SLO by pass filters and engine oil as per manufacturer specifications and quantity complete all as directed by Engineer-in-Charge . Notes:- (i) 'B' check shall be carried out once in every six months or 250 hours of running of DG Set whichever is earlier. Servicing of DG Set alongwith connected Alternator and Panel Board and the Contractor shall carry out periodical inspections during the maintenance period and he shall be responsible for the smooth functioning of the DG set for a period of 30 days from the date of service and shall also attend all the maintenance works as and when required in that period except in case of Major repairs (ii) Fan belt, Air filter, Engine oil and radiator coolant oil required for replacement during the maintenance period shall be measured and paid separately at supply only rates and cost of labour for fixing these spares/ filling of oils shall be deemed to be included in the rate quoted for this item. (iii) Cost of all consumables required during the maintenance period shall be deemed to be included in the rate quoted for this item,contractor to be provided fuel filter, oil filter, water filter,top head gaskets,fuel pipes, battery terminal, battery lead and distilled water. (iv) List of checks to be carried out under 'B' check is attached as Appendix 'B' to the Particular specifications. and the spares and consumables shall be purchased from Original manufacturers/ manufacturer authorized stockiest/ distrubutor/ dealer only by the contractor and submit GST vouchers to Deptt while claiming payments and also the contractor always keep minimum required consumable quantities in hand as a pro-active/ preventive maint/ breakdown.(v) A record of repairs carried out in each visit of each DG set installation to be maintained separately duly signed by Contarctor, JE and Engineer-in-charge. The maintenance certificate duly signed by contractor and concerned JE E/M and Engineer-in-Charge seperately of each DG set visit. 250 KVA DG Set Make : Cummins - Model- 6CTAA at Power House (vi) The contractor shall be attending the breakdown during the entire period of contract by finding the fault and rectifying the fault within 24 hours on intimation by JE/Engr-in-charge and ensure that the fault is rectified within 48 hours failing which an amount of Rs. 300/- per hour will be recovered from contractor due and spare of minor in nature shall be deemed to be included in the rate quoted by firm.
All as per item No 01 above but 140 KVA DG set Make:-Cummins -type- 6CTA
All as per item No 01 above but 125 KVA DG set Make:-Cummins -type- 6BTA
All as per item No 01 above but 125 KVA DG set. Make: Mahindra behind REB
All as per item No 01 above but 100 KVA DG set. Make: Kirloskar -type-RB66 TA.
All as per item No 01 above but 100 KVA DG set. Make:-Cummins -type-NTC 495 G
All as per item No 01 above but 100 KVA DG set. Make: Kirloskar -type-6R1040 TA at CCC. (100 KVA DG set -02 Nos)
All as per item No 01 above but 82.5KVA DG set. Make:-Cummins -type-6BT
All as per item No 01 above but 40 KVA DG set. Make:-Cummins
Overhauling of following mentioned Self Starter assembly of DG Set by disconnecting and removing from the engine , cleaning all accessories, replace the wornout parts like :- brushes, bushes, contact plates, jumping leads and seals, revarnishing the field coil, armature and reassembling the same , refitting to the engine , including testing on load after repairs all as directed . Self starter assembly, 24 Volt DC [Make - Delco Remi]/ Self starter assembly, 24 Volt DC [Make - lucas TVS ]
All as per item No 10 above but Self starter assembly, 12 Volt DC [Make - lucas TVS ]
Checking for over heating of engine and raise in range of water temp guage above normal , disconnecting the radiator hoses and taking down the radiator assembly complete from the engine , dismantling the top & bottom chambers , descalling the sediments and scales , corrosion etc., by means of acid cleaning and high pressure water washing , air blast cleaning , re- assembling the same with new gaskets, including arresting leakage , if any and fixing to the engine with new hoses ,clipes all as required and as directed. Note : The rate qouted shall be inclusive of transporting of the radiator to the workshop and back and all incidental charges. 250 KVA DG Set .
All as per item No 12 above but 140 KVA DG set.
All as per item No 12 above but 125 KVA DG set.
All as per item No 12 above but 100 KVA DG set.
All as per item No 12 above but 82.5KVA DG set.
All as per item No 12 above but 40 KVA DG set.
Checking the engine for abormal running of engine due to improper flow of fuel ,overhauling the fuel injection pump assy and Injectors by disconnecting the fuel supply lines, and taking out FIP to workshop for servicing /repair , replacing the worn out / un- servicable parts like service kit, D - Valve, Elements , nozzles etc., as required and calibrating the same for increasing proper flow with pressure & efficiency , assembling at site and testing on load all as directed for the following capacity of Gen sets :- 250 KVA DG Set . Make : Cummins
All as per item No 18 above but 140 KVA DG set. Make:-Cummins
All as per item No 18 above but 125 KVA DG set. Make:-Cummins
All as per item No 18 above but 100 KVA DG set. Make: Kirloskar
All as per item No 18 above but 100 KVA DG set. Make:-Cummins
All as per item No 18 above but 82.5KVA DG set. Make:-Cummins
All as per item No 18 above but 40 KVA DG set. Make:-Cummins
Supply only Lead acid battery 12 volt 180 AH
Supply only Lead acid battery 12 volt 150 AH
Supply only Lead acid battery 12 volt 110 AH
Supply only Engine Oil SAE 15W-40W.
Supply only radiator coolant.
Supply only fan belts as per existing make for the following capacities of DG sets :- 250 KVA DG Set . Make : Cummins
All as per item No 30 above but 140 KVA DG set. Make:-Cummins
All as per item No 30 above but 125 KVA DG set. Make:-Cummins
All as per item No 30 above but 100 KVA DG set. Make: Kirloskar
All as per item No 30 above but 100 KVA DG set. Make:-Cummins
All as per item No 30 above but 82.5KVA DG set. Make:-Cummins
All as per item No 30 above but 40 KVA DG set. Make:-Cummins
Supply only Air filter element as per existing make for the following capacities of DG sets. 250/ 140 KVA DG Set . Make : Cummins
All as per item No 37 above but 125/100 KVA DG set. Make:-Cummins
All as per item No 37 above but 82.5/ 40KVA DG set. Make:-Cummins
Supply only Solenoid switch, 24 Volts, DC Suitable for 250/140 KVA DG SET
Supply only Solenoid switch, 12 Volts, DC Suitable for 125/100 KVA DG SET
Supply only Solenoid switch, 12 Volts,DC Suitable for 40 KVA DG SET
Supply only electronic Hooter 12 volts DC all as speciifed and directed.
Supply only Water Temp gauge with adopter all as specified and as directed.
Supply only Oil Temp gauge with adopter all as specified and as directed.
Supply only Oil pressure meter with pipe all as specified and as directed.
Supply only Timer AC / DC all as specified and as directed.
Supply only PLA Relay with Base AC/DC all as specified and as directed.
Supply only Single phase preventer all as specified and as directed.
Supply only MCB 16Amps,DP,230 Volt all as specified and as directed.
Supply only Push Button for start , stop, reset all as specified and as directed.
Supply only Digital type Frequency meter all as specified and as directed.
Supply only Digital type Voltmeter all as specified and as directed.
Supply only Digital type Ammeter all as specified and as directed.
Supply only Indicator lamps [LED Type] all as specified and as directed.
Supply only Two pole ON/OFF switch assembly all as specified and as directed.
Supply only LLOP switch assembly all as specified and as directed.
Supply only HWT switch assembly all as specified and as directed.
Supply only Ignation switch assembly all as specified and as directed.
Supply only Battery cable copper single core multistand 25 sqmm with terminals length 1.5 meter all as specified and as directed.
Supply only surge suppressor for MCX 41-44 all as specified and as directed.
Supply and fix water Pump assembly including taking out the unserviceable water pump assembly and testing on load for proper functioning for the following capacities of DG sets :- 250 KVA DG Set Make : Cummins - Model- 6CTAA at Power House/ 140 KVA DG set.Make:-Cummins -type- 6CTA
All as per item No 64 above but 125 KVA DG set.Make:-Cummins -type- 6BTA / 100 KVA DG set.Make: Kirloskar -type-RB66 TA. / 100 KVA DG set.Make:-Cummins -type-NTC 495 G
All as per item No 64 above but 82.5KVA DG set. Make:-Cummins -type-6BT/ 40 KVA DG set. Make:-Cummins
Supply and fix Automatic Voltage Regulator Suitable for140KVA/ 250 KVA DG set incl taking out old unserviceable AVR all as specifed and as directed.
Supply and fix Automatic Voltage Regulator Suitable for 125/100 KVA DG set incl taking out old unserviceable AVR all as specifed and as directed.
Supply and fix Automatic Voltage Regulator Suitable for 82.5/40 KVA DG set incl taking out old unserviceable AVR all as specifed and as directed.
Supply and fix Rotating Rectifier Assy Suitable for 250 KVA DG set incl taking out old unserviceable rectifier assy all as specified and as directed.
Supply and fix Rotating Rectifier Assy Suitable for 140/125/100 KVA DG set incl taking out old unserviceable rectifier assy all as specified and as directed.
Supply and fix Rotating Rectifier Assy Suitable for 82.5/40 KVA DG set incl taking out old unserviceable rectifier assy all as specified and as directed
Supply and fix Starter Motor assembly Suitable for 82.5/40 KVA DG set 12 volt incl taking out old unserviceable starter motor assy all as specified and as directed make : Lucas TVS
Supply and fix electronic governor controller suitable for 250 kva dg set incl taking out old unserviceable starter motor assy all as specified and as directed
Supply and fix microprosser based engine control unit suitable for 250/140 kva dg set incl taking out old unserviceable starter motor assy all as specified and as directed [Make : BERNINI]
M/L for fixing the static SCR type 20Amps battery charger 24 volt DC in existing control panel including necessary connections , cutting for fixing the volt meter , ammeter and connecting the battery all as directed.[Make : Naren]
M/L for fixing the static SCR type 15 Amps battery charger 12 volt DC in existing control panel including necessary connections , cutting for fixing the volt meter , ammeter and connecting the battery all as directed.[Make : Naren]
.M&L for spray painting of DG sets complete upto 250 KVA capacity with one coat of synthetic enamel paint of existing colour and writing MES/ SM No all as specified and as directed.
Supply and fix contactor 4 pole, 160 amps 415 Volts Model no MCX 32 including taking down unserviceable contactor all as specified and as directed.
Supply and fix contactor 4 pole, 400 amps 415 Volts Model no MCX 43 including taking down unserviceable contactor all as specified and as directed.
Supply and fix MCCB 4 pole 63 A rating, 25 KA with 80-100 thermal settings in LT panel including taking down unserviceable MCCB all as directed.
Supply and fix MCCB 4 pole 250 Amps , 36 kA, with 200-250 thermal settings 415 volts including taking down unserviceable MCCB all as directed.
Supply only Intelligent panel meter model QUASAR class 0.5, 3 ph 4W IPM 240V (L-N) 5A, CL1 FM Make : L&T Cat No. WI300 FC5300
All as per item No 84 above but 140 KVA DG set Make:-Cummins -type- 6CTA at MAP II
All as per item No 84 above but 125 KVA DG set Make:-Cummins -type- 6BTA at power house and 125 KVA DG Set. Make : Mahindra
All as per item No 84 above but 100 KVA DG set. Make: Kirloskar -type-RB66 TA.at power house
All as per item No 84 above but 100 KVA DG set. Make:-Cummins -type-NTC 495 G at DMSS
All as per item No 84 above but 100 KVA DG set. Make: Kirloskar -type-6R1040 TA at CCC (100 KVA DG set-02 Nos )
All as per item No 84 above but 82.5KVA DG set. Make:-Cummins -type-6BT at pump house
All as per item No 84 above but 40 KVA DG set. Make:-Cummins at MAP I
Spray painting of LT/AMF panel etc by applying one coat of primer and two coats of synthetic enamel paint as approved by Engineer-in-charge duly scratching out old corroded area of the surface including providing hinges by welding to the door of panels as required all as specified & directed.
M/S Bhagyawanticonstruction
B5BUILDING SOLUTIONS
Lucky Enterprises
Bidder Name
devan enterprises
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .