| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.7 LAccepted-AOC 300 PREM BASTI 10 SANGRUR SANGRUR PUNJAB 148001 | SANGRUR | PUNJAB | 148001 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹10.7 L+₹1.0 L (10.8%)Rejected-Finance | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹12.0 L+₹2.3 L (24.3%)Rejected-Finance 19 L LEHAL COLONY STATE COLLAGE ROAD PATIALA 147001 | PATIALA | PATIALA | PUNJAB | 147001 | L3 | Rejected-Finance Being L3 |
Tender Value
Refer Docs
EMD Value
₹24,260
Closing Date
4 Oct 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Sh Himanshu, IDSE
MILITARY ENGINEER SERVICES GARRISON ENGINEER SOUTH TARAPORE ENCLAVE PATIALA CANTT
As per tender documents
2022_MES_550811_1
GE(S)/PAT/T-42/N/2022-23
Open Tender
Civil Works
Item Rate
180 days
Mil Stn Nabha
Refer tender documents
8 documents required · 8 mandatory
₹500
Yes
GE (South) Patiala
₹24,260
Yes
2 Dec 2022
8 Sept 2022
6 Oct 2022
8 Sept 2022
4 Oct 2022
21 Sept 2022
8 Sept 2022 - 14 Sept 2022
Amount
Excavation in trenches n exc 1.5m wide and n exc 1.5m in depth for foundation etc.
PCC 1:4:8, type D-2 using 40mm graded stone aggregate, as in foundation etc. complete all as specified and directed.
M&L 40mm thick 1.2.4 type B-0 Damp proof course to horizontal or vertical surfaces including necessary formwork compleate all as specifiede and directed.
Brick work, with sub class ‘B’ bricks, straight or curved on plan exc 6 m mean radius built in cement mortar 1:4, using old size bricks complete all as specified and directed.
S&F Factory made steel windows box type using ERW hollow 'P' section comprising double frame for glaged and gauged skelton shutters jointed interally with flat iron 40x4mm complete including grill of 8mm square bar, fixed horrizontally @ 10cm centre to centre, hinges, handle tower bolts,lugs etc all as shown on drawing noTD-219 (c) sheet 1/3 to 3/3 and TD-220 (c) sheet 1/3 to 3/3 as applicable complete (Note;- (i) for the purpose of measurement& payment double shuttre with frame shall be considered as one unit.)
M&L for Reinforced cement concrete (Normal Mix),Type B1, 1:2:4 using 20 mm graded stone aggregate in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete, Footings
M&LM&L for Reinforced cement concrete (Normal Mix),Type B1, 1:2:4 using 20 mm graded stone aggregate Chajjas on walls, beams lintel beam, roof beam , landings, balconies, canopies, deck slabs and in shelves and the like
M&LM&L for Reinforced cement concrete (Normal Mix),Type B1, 1:2:4 using 20 mm graded stone aggregate Columns, pillars, piers, posts and struts
Use & waste of formwork to sides and soffits of floor, colume , roof beams ,lintels beam ,cantilevers ,shelves including supports ,overhangs and similar work , for rough finished flat surfaces all as directed by Engr-in-Charge.
Form work to sides of slab not exc 20cm wide for rough finish surface complete all as specified.
Mild steel TMT bars 10mm dia & over cut to length, bent to shape required incl cranking bending with0.9 mm dia MS wire (annealed) not less than0.9 mm dia or securing with clips.
All as per Item No 11 but 5mm dia and over upto and incl 10 mm dia in stirrups, spacers and binders.
Sheet glass ordinary quality 4 mm thick and glazing with oil puttly or wooden beads in square not exceeding 0.5 sqm in each pane complete all as specified and directed.
S & F Wire netting of galvanised steel wire 1.40mm dia and size of mesh 25mm fixed with wooden beds tinned tacks of wire staples
M & L for 15mm thick ( in two layers of 10mm and 5mm thickness) cement pastering in cement mortar 1:4 and mixig the water proofing compound as per manufactures instructions on brick or concrete surface of wall finished complete all as specified and directed Note : Water proofing compound shall be measured and paid saparately under item .
Supply only integral water proofing compound ISI marked.
M&L 10mm thick cement plastering in cement mortar CM 1:6 finishing the surface even and fair without using extra cement complete all as specified
Preparation of new plastered or unplastered surfaces of walls and applying two coat of cement base paint over a coat of white wash.
M&L Preparation of new plastered or unplastered surfaces of walls and applying two coats of distemper oil emulsion over all as specified.
M&L for hardcore of gauge n.exc. 63 mm, deposited, spread and levelled in layers n.exc. 15 cm thick, watered and rammed to a true surface using broken stones or boulders, complete all as specified and directed.
M&L 100 mm thick PCC 1:4:8 type D-2 using 40 mm graded aggregate as in sub base,complete all as specified and directed.
M&L 100 mm thick (1:2:4) Type B-1, Plain cement concrete with using 20mm graded aggregate as in hard standing etc finished with without using extra cement , complete all as specified and directed.
S & F for pre painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/clading to wall, fixed to self tapping screws as specified
S&F pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 mpa as in ridges, roof covering/clading to wall, fixed with self tapping screws as specified.
Rolled mild steel work in roof truses (Framed), trussed purlins made of Beam, tees, angle, channels or feat section conforming to Fe-290 (Gde E-165) including cleats, distance pieces etc complete all as specified and directed. (The rates shall inclusive of getting the truss designed by Thapar Engineering College, Patiala). The Contractor shall get the truses designed from Thapar Engr College, Patiala based on the span of 8 m and shall provide the design calculations done by the Engg College.
S&F mild steel plate girder or single stanchions, built up of one beam or channel section with flange plates, caps, bases, splices, angle brackets, cleats and other connections complete all as specified and directed.
M& L for Preparation new steel surfaces of any description not otherwise described over 10cm width or grith and applying two coats of synthetic enamel paint over one coat of red oxide as in primer all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm in soft/loose soil, complete all as specified and directed.
Removing excavated material n.exc 50m and depositing where directed at a lavel .exc 1.50 mtr above the starting point.
Machine cut Kota stone slab flooring 20mm (+2mm) thick laid over and including 15 mm thick screed bed or bedding layer in cement mortar 1:4 as base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed.
PCC (1:3:6), 50mm thick as in PCC path/ plinth protection.finished the surfaces even and fair with out using extra cement
S&F Fe290 (Gde E-165) Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging also fastening.
M&L anodised aluminium snap grid false ceiling of grid size 605x605mm consisting of aluminium main and "T' sections of size 25x35x1.5mm thick and wall angles of size 25x 25x 1.5 mm thick suspended with GI wire suspenders of 6mm dia of suitable length and 8-10 mm thick gypsum board, 60x60 cm size fixed with staples on snap grid complete all as specified and directed by Engr-in-Charge.
Taking down carefully copper/aluminum point wiring (light, fan, socket or power) complete with fittings and fixtures such as switches, ceiling roses, pendants, regulators, socket, lamp, holders brackets, bulk head, mirror light fittings etc removing material for taking credit ( credit shall be recovered as per credit Sch attached) and also making good disturbed surfaces of wall, floors etc all as specified and as directed by the Engineer-in-Charge.
M&L for point wiring with 1.50 sqmm in copper conductor cable ( multistrand) FRLS single core PVC insulated cable in and including PVC concealed conduit ( ISI Marked) of heavy duly with all accessories ie PVC gutties etc terminated in sunken/pressed metal flush box and white modular cover plate with frame for mounting of switches /sockets/ fan regulators etc and continuous earth wire 1.5 Sqmm copper cable PVC insulated FRLS controlled by one switch for one light/fan/sockets point/ all as specified and directed by Engr-in-Charge in ceiling Portion surface conduit wiring to be done. Note : i) Eye/bottle thimbles shall be used for connection in switches/sockets & MCB's in DB's without any extra cost ii) Electric rewiring should be done in proper colour coding i.e. Red for phase, Black for neutral and Green for Earth. (iii) Necessity cutting chasing where ever required shall be part of job & making good the disturbed surfaces shall be part of job.
All as per item No 2 above, but for one 3/5 pin socket outlet 5 Amp on the same board with other switches complete all as specified and as directed by the Engineer-in-Charge.
All as per item No 2 above, but for one 3/5 pin socket outlet 5 Amp on independent board complete all as specified and as directed by the Engineer-in-Charge.
All as per serial item No 2 here-in-before , but for one socket outlet 15 Amps on independent board with 2.5 Sqmm copper conductor ( Multi-stranded) PVC insulated and unsheating electric cable 1100 volts (ISI Marked) including PVC insulated and unsheathed electric cable 1100 volts 2.5 Sqmm copper stranded conductor as continuous earth wire connected to common earth dolly complete all as specified and as directed by Engineer-in-Charge.
Supply & Fix in replacement of modular switch 1 way, 6 Amps, 1 module completeall as specified.
Supply & Fix of modular type, switch 1 way, 16 Amps, 1 module complete all as specified.
Supply & Fix modular type, socket 5 pin 6 Amps, 2 module complete all as specified.
Supply & Fix modular socket 5 pin 6/16 Amps, combination type 2 module complete all as specified.
Supply & Fix modular Fan regulator step type, 120 watts, 1 module complete all as specified.
Material and labour for ceiling rose surface type, 65 mm x 50 mm two to three terminals / PVC / polycarbonate, isolated body fixed on PVC block complete all specified and as directed by the Engineer-in-Charge.
Supply and fixing Vertical load line type TPN DB, 4 way 415 V, double door as per IS - 8623, IP-54 protection, universal mounting with suitable capacity copper bus bar with nuetral bus bar, earth bar and cable ties for cable management, top and bottom removable gland plate suitable for accomodate MCCB TPN 100 Amp as incomer and TP&SP MCCB/MCBs as outgoing complete & making necessary electrical connection for incoming and outgoing cables, with copper lugs, crimpped with crimping tool complete all as specified and directed. Note: (i) Connnections of the MCB'S shall be done with appropriate size of brass/Cooper thimble. (ii) The disturbed surface shall be match with existing shall be part of job.
S&F in replacement of existing MCCB TPN, 63 Amps, 415 volts, 16 KA complete fixing in DBs including proper thimbles connections all as specified and directed.
Supply & fix in replacement of existing unserviceable Sheet metal enclosure with new DB’s suitable for MCBs of single pole and neutral 8 way double door type with 200 amp rated bus bar. Note: i) Connnections of the MCB'S shall be done with appropriate size of brass/Cooper thimble. ii) The disturbed surface shall be match with existing shall be part of job.
Supply and fixing 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 6 to 32 Amp, in the MCB DB Complete with connection testing and commissioning complete all as specifed and directed
Supply and fixing 240V, 10 KA 'B' curve miniature circuit breaker (MCB) SPN current carrying capacity 6 to 32 Amp, in the MCB DB Complete with connection testing and commissioning Complete all as specifed and directed
M&L for Sub main wiring with 2 runs of single core FRLSH PVC insulated unsheathed multistranded copper conductor cable of size 2x6 sqmm ( line conductor) & 1x4 sqmm ( earth conductor), 1100 volt grade drawing in & including heavy duty non metallic PVC conduit , ISI marked, incl accessories not less than 25 mm in dia & concealed in wall, roof etc including PVC insulated, FRLSH unsheathed single core multistranded copper conductor cable, green in colour as earth conductor including cutting charges for concealed conduit wiring etc and making good cutting not exceeding 10 cm grith complete all as specified and directed. Note: (i) Electric rewiring should be done in proper colour coding i.e. Red for phase, Black for neutral and Green for Earth . (ii) Connections of cables with MCBs or bus bars shall be done through brass/copper thimbles of appropriate size . (iii) Two runs of copper conductor cable and one run of copper earth wire including PVC conduit will be measured and paid as one unit only.
Supply, laying, Jointing connecting in replacement of existing multijointed OH conductor into LT UG cable XLPE insulated,PVC bedded galvanised steel strip or wire armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 25 sqmm 4 core laid in trenches / on poles / walls / in ducts / passing through pipes and including necessary cable lugs, bolts, nuts and washers complete all as specified and directed.
Supply & fix in replacement of FTL with new techonlgy LED having high efficiency of capacity LED 20 Watt, 4 feet long, FIXT ELITE PRIDE PLUS 20 W 6500K, Cool Day Light (CDL) LHEXBLP7PN1W020. Make -Havells incl necessary electric conection complete all as specified.
Supply & fix in replacement of LED 10 Watt, 2 feet long, Cool day light with NEO Batten10 W 6500K having high efficiency Cat No. LHEXACP7IN1W010. Make -Havells. incl necessary electric conection complete all as specified.
S & F LED light fitting 1x9W/1X10W bulkhead luminaires 230 Volts including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified by Engr-in-Charge.
S&F Wall mounted fan 450 mm sweep, 18 Inch, 1440 rpm metal body, 240 volts, energy efficent as per latest specifications Havells or equivalent in Usha/ Bajaj and Almonard all as specified and directed by Engr-in-Charge.
S & F new generation energy saving and environmental friendly long life LED building security light 1x25 watts made up of pressure die cast alluminium housing with high power LED as light source and lense embedded PC cover having TOP OPENING separate driver compartment with IP65 protection and impact resistance of IK07, with all accessories including suitable bracket with suitable dia light grade GI pipe bend to shape, including MS clamp of size of required size and PVC cable 1.5 Sqmm twincore from ceiling rose to light fittings complete all as specified and directed.
S & F Single pole and neutral enclosure with a two pin and earth plug and socket 240 volts complete with one single pole MCB 20 Amps suitable for 1.5 TR AC all as directed by Engr-in-Charge.
M&L for replacement of existing unserviceable earthing complete with galvanized steel earth plate electrode 600x600x6mm tthick buried directly in ground(earth plate not less than 2.25 mtr deep below the normal ground level ) with top edge of plate not less than 1.5 mtr below the normal ground level connected to galvanized earth wire 4mm dia by means of nuts bolts,washers,check nuts of iron or steel including test point PCC pits and RCC cover in PCC 1:2:4 (type B-1) including iron angle frme 40*40*6mm. and medium grade GI watering pipe 20mm dia with funnel and wire mesh and 15 mm bore GI pipe light grade proection pipe including excavation and charcoal ,common salt surrounded with 15cm all around the plate all as specified and shown in EP-3 of SSR Part-I
Excavating in trenches n exc 1.5m wide and n exc 1.5m deep and getting out in soft/loose soil complete all as specified and directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers n exc 25cm complete all as specified and directed.
Removing excavated material n exc 50m and depositing where directed at a level n exc 1.5m above the starting point complete all as specified and directed.
Material and labour for sand cushioning with dry river sand in trenches for cushioning of underground cable line including spreading, leveling, well ramming completed all as specified and directed.
Supply and laying well burnt sub class ‘B’ bricks. ( designated 75) locally available best quality laid dry in trenches for protection of underground cable all as specified and directed.
Material and labour for replacement of GI tubing light grade 40 mm bore for passing through cables under the floor, along the wall or along the pole complete all as specified and directed.
AR CONSTRUCTIONS
Vipin Kumar and Brother
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .