GE(W)/HSR-49/2023-24 REPAIR/REPLACEMENT OF STREET LIGHTS AND CONNECTED WORKS AT EBS BHOJRAJ AND CHANNIBARI UNDER GE (WEST) HISAR
2023_MES_626862_1
GE(W)/HSR-49/2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Hisar Mil Stn
As per NIT
8 documents required · 8 mandatory
₹500
GE West Hisar
₹30,000
Yes
29 Jan 2024
4 Nov 2023
6 Dec 2023
4 Nov 2023
4 Dec 2023
20 Nov 2023
Amount
Checking of street light/flood/building fittings any type on pole/wall to find out defect on site and repairing to cable connection/loose connection /necessary cleaning the bowl/perpex cover whre provided and testing complete all as specified and directed. Note : (i) Spares of light fittings shall be measured & paid separately) (ii) The T&P Vehicles and necessary ladders etc will be arranged by the contractor and the cost of maint deemed to be included in the quoted rates (iii) Contractor are bound to depute daily 2 Nos Electrician for above work site (EBS, Bhojraj & Channibari), the complete deemed cost should be included in above quoted rate by contractor.
Supply only surge protector 10 kA with IP 65 protection, as per IS complete all as specified and directed.
Supply only driver suitable for 45 watt LED with IP 65 protection, as per IS complete all as specified and directed.
Supply only driver suitable for 60 watt LED with IP 65 protection, as per IS complete all as specified and directed.
Labour for repair of street lights at MES store yard by electrician, cleaning, taking out unserviceable minor part, fixing of new part which required and testing for continuous hours complete all as specified and directed. (i) Contractor are bound to depute 1 Nos Electrician and 1 Nos labour for above work to repair the lights with in 24 Hrs , the complete deemed cost should be included in above quoted rate by contractor.
Supply and fixing energy efficient LED street light fitting of 45 Watt epoxy powder coated pressure die cast aluminium housing to act as heat sink for efficient dissipation of heat and toughened glass with IP 66 degree of protection, system luminous efficiency more than 100 lumens / watt individual LED's should have lenses for better throw across and along road, PF>0.9 with voltage range 140 to 270 Volt, fitting should be provided with inbuilt 10 KV minimum surge protection, short circuit and over voltage protection facility for Driver and fitting including making electrical connection Including bracket of suitable size upto 1.5 mtr long & MS Flat clamp of suitable size complete all as specified and directed. Make- Polycab/ havells/ Halonix/ Crompton/ C & S
Supply and fixing energy efficient LED street light fitting of 60 Watt epoxy powder coated pressure die cast aluminium housing to act as heat sink for efficient dissipation of heat and toughened glass with IP 66 degree of protection, system luminous efficiency more than 100 lumens / watt individual LED's should have lenses for better throw across and along road, PF>0.9 with voltage range 140 to 270 Volt, fitting should be provided with inbuilt 10 KV minimum surge protection, short circuit and over voltage protection facility for Driver and fitting including making electrical connection including bracket of suitable size upto 1.5 mtr long & MS Flat clamp of suitable size complete all as specified and directed. Make- Polycab/ havells/ Halonix/ Crompton/ C & S
Supply and fixing energy efficient LED Flood light fitting of 120 Watt epoxy powder coated pressure die cast aluminium housing to act as heat sink for efficient dissipation of heat and toughened glass with IP 66 degree of protection, system luminous efficiency more than 100 lumens / watt individual LED's should have lenses for better throw across and along road, PF>0.9 with voltage range 140 to 270 Volt, fitting should be provided with inbuilt 10 KV minimum surge protection, short circuit and over voltage protection facility for Driver and fitting including making electrical connection including bracket of suitable size upto 1.5 mtr long & MS Flat clamp of suitable size complete all as specified and directed. Make- Polycab/ havells/ Halonix/ Crompton/ C & S
Supply and fixing in replacement PVC insulated stranded aluminium conductor cable sheathed 10 Sqmm flat twin core for connection for street light fitting with over head lines / service connection complete all as specified and directed.
Supply and fixing in replacement PVC insulated stranded aluminium conductor cable sheathed 6 Sqmm flat twin core for connection for street light fitting with over head lines / service connection complete all as specified and directed.
Supply and fixing in replacement PVC insulated stranded aluminium conductor cable sheathed 4 Sqmm flat twin core for connection for street light fitting with over head lines / service connection complete all as specified and directed.
Taking out old unserviceable under ground PVC/XLPE LT cable of any size from trenches/ wall/roof/road/pipe/pole including segregation of serviceable bricks for re-use complete all as specified and directed.
Relaying of old serviceable under ground PVC/XLPELT cable any grade and any size in trenches/fixed to wall/pole/roof/laid in floor including necessary connections and thimbling complete all as specified and directed. Note : Earth work, brick & sand cushioning shall be measured and paid for separately under appropriate item.
Supply and Laying LT cable of size10 Sqmm 2 core 1100 Volt grade aluminium conductor laid in trenches / fixed to wall / pole / laid in floor including necessary connection and suitable size of thimbling complete all as specified and directed. Note :- (i) Excavation, earth work, sand cushioning, brick protection, cutting of road and pipe shall be measured and paid separately under appropriate item of this schedule.
All as per Srl item No 14.00 here-in-before but size of cable 16 Sqmm 4 Core Note for item No 14.00 and 15.00:- Excavation ,earth work and cutting of road /floor shall be measured and paid separately.
Excavation in trenches not exceeding 1.5 meter wide and not exceeding 1.5 meter in depth for foundation, laying of cables or pipes (where provided) for protection of cable or fixing poles and stays and struts and getting out in soft/loose soil including trimming the sides and forming bottom surfaces to required levels complete all as specified and directed .
Returning, filling in, approved soft/loose soil, including spreading, leveling, watering and well ramming in layers not exc 25cm thick complete all specified and directed.
Removal of surplus excavated soil to a distance not exceeding 50 meter and depositing where directed at a level not exceeding 1.5 meter above the starting point complete all specified and directed.
Supply and filling Local sand cushioning , with dry and clean sand, over and under the under ground cables in trenches, ducts for cable protection including consolidation, 80mm thick to the authorized width as per SSR–Part-I before laying of cable and 150mm thick after laying of cable complete all as specified and directed.
Supply and laying Best quality, locally available, sub class ‘B’ bricks (Old Size) for cable protection cover, laid flat and dry in trenches over the cable , perpendicular to the direction of cable complete all as specified and directed.
Re-laying only old bricks, locally available, sub class ‘B’ bricks (Old Size) for cable protection cover, laid flat and dry in trenches over the cable , perpendicular to the direction of cable complete all as specified and directed.
Cleaning and preparation of old painted surface of street light PCC pole 9mtr long and making alternative black and white strips on pole with synthetic enamal paint (each strip 30 cm height) upto 1.5 mtr height from top of PCC foundation block complete all as specified and directed.
Material and Labour for earthing complete with galvanized iron of street or earth plate of size 60cmx60cmx6 mm thick buried directly in ground. Vertically total depth not less than 2.25 mtr below normal ground level with top edge of earth plate at depth of not less than 1.5 mtr below ground level surrounded from all sides with alternate layers of charcoal and common salt and connected to GI earth wire 4 mm thick by means of GI bolts, nuts washers & check nuts and soldering the strip, electrode connected to panel board or on poles including GI protection pipe 40 mm light grade dia for protection of strip upto test point all as directed GI pipe medium grade 20 mm bore for watering including providing funnel and wire mesh CI frame and 10 cm thick suitably reinforced RCC pit cover PCC chamber pit with PCC 1:3:6 type C2 using 40 mm graded stone aggregates complete including excavation and earth work, all as specified and show in plate No 3 of SRR-2009 Part-1, PCC pit shall be provided at least 50cm away from the earth pit and not just on earth pit including testing on completion, complete all as specified and directed..
Supply and fixing in replacement Sheet metal enclosure including 32 Amp MCB SPN with provision of duct for incoming and outgoing cable complete all as specified and directed.
Opening /disconnecting the electrical connection of defective/burnt out underground LT cable of any size any core from main switch/DB/junction box / LT panel/ L T O/H line etc. Taking out the required length of cable from existing loop, cutting the defective portion of cable, providing required thimbles/ connectors at cable end and reconnecting the cable in previous location with existing main switch/DB/Junction box/LT panel/O/H line etc complete all as specified and directed. Note:- (i) The cost of required earth work ie excavation, returning filling, relaying of sand/bricks and cost of drawing the required length from protection pipe ,breaking of required brick work/plaster/concrete and redoing the required cement work to match the existing surface is deemed to be included in quoted rates and nothing extra should be paid on this account.(ii)Additional cable/ protection pipe required at site shall be measured and paid separately.
Supply and fixing LT cable junction box, dust and water proof made out of PVC non- metallic sheet FRP type, factory made, size of box 250x200x100mm deep with swiveling cover and locking clamp, consisting of aluminium bus bar strip 150mm x 30mm x 3mm, 4 Nos mounted on PVC insulator and provision of incoming/outgoing cables with grommets, including in built 6Amp MCB, SP, 9/10KA one No complete all as specified and directed. Note :- MS clamps and nut bolts for fixing the box along pole shall be included in the quoted rate.
Supply and fix GI pipe bracket of 1.25 m long and made out of 32/40 mm dia light grade pipe including MS clamp of size 25 x 4 mm - 02 Nos for holding one bracket, nut and bolt with washer duly painted with aluminium paint over one coat of primer of suitable size complete all as specified and directed.
Supply and fixing in replacement of MCB , SP ,240Volt, 6 Amp 10KA complete all as specified and directed.
Supply and fixing of nature switch (using Infrared sensor technology) based automatic street light control panel. The panel should be suitable enough ro take single phase load of 5 to 8 KW with contactor incoming MCB & Outgoing MCB rating of 40 Amp and main load circuit wire(copper) of minimum 10 Sqmm. Nature switch operation should be based on Natural Light Lux Level. Required illuminance level for switching ON is< 60 Lux and for switching OFF > 10 Lux The sensor should also have part night operation facility of min. 4 hrs to max 12 hrs. The sensor along with suitable power contractor and incoming- outgoing MCBs should be enclosed in a pole/ wall mounted Rust proof, electric shock proof, termite proof and FR grade SME enclosure confirming to IP54. the circuit should also have provision for manual operation (i.e Sensor By-pass option) complete all as specified and directed. Make- Kakatiya energy system/Bajaj/Healer
Cutting/trimming of tree branches upto 1.50 mtr distance on both sides of LT over head lines including collection and removal from road complete all as specified and directed.
Supply and fixing in replacement LED post top lantern 25 Watt with aluminium die cast housing with frosted glass for glare free lighting complete all as specified and directed. Make- Havells, Polycab, Surya, Crompton etc
KUNAL ENTERPRISES
YASHU CONTRACTORS
M/s Devendera construction
M/S RAJESH KUMAR & SONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .