| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹13.8 LAccepted-AOC | 1 | Accepted-AOC L1 | |
| 2 | 2₹14.5 L+₹70,153 (5.08%)Rejected-AOC | 2 | Rejected-AOC L2 | |
| 3 | 3₹18.0 L+₹4.2 L (30.5%)Rejected-AOC 145 1 0 NEAR OLD LIC SHIV NAGAR VILLAGE TOWN MODIPURAM CITY MEERUT MEERUT UTTAR PRADESH 250110 INDIA | MEERUT | UTTAR PRADESH | 250110 | 3 | Rejected-AOC L3 | |
| 4 | 4₹20.2 L+₹6.4 L (46.7%)Rejected-AOC | 4 | Rejected-AOC L4 | |
| 5 | 5₹20.9 L+₹7.1 L (51.5%)Rejected-AOC MUZAFFARNAGAR MEERUT ROAD GEHRA BAGH OPP PWD WARE HOUSE MUZAFFARNAGAR UTTAR PRADESH 251002 | MUZAFFARNAGAR | UTTAR PRADESH | 251002 | 5 | Rejected-AOC L5 |
Tender Value
₹20.5 L
EMD Value
₹21,000
Closing Date
7 Oct 2021, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Superintending Engineer
Electricity Transmission Circle-II, U.P. Power Transmission Corporation Ltd. 57- George Town, Prayagraj
69/ETC-II(P)/ 2021-2022
2021_UPTCL_626231_1
69/ETC-II(P)/ 2021-2022
Open Tender
Electrical Works
Item Rate
90 days
Shankergarh
Please refer Tender documents.
2 documents required · 2 mandatory
₹2,360
EE,ETD-NAINI,PRAYAGRAJ
₹21,000
23 Feb 2022
1 Oct 2021
8 Oct 2021
1 Oct 2021
7 Oct 2021
2 Oct 2021
120 days
Amount
Part "A" Supply
Supply of bolted type tension fitting along with turn buckle and all accessories for single panther conductor for 132 KV Transfer Bus as per sample.
Supply of bolted type tension fitting without turn buckle and all accessories for single panther conductor for 132 KV Transfer Bus as per sample.
Supply of bolted type tension fitting along with turn buckle and all accessories for twin ACSR Moose conductor for 132 KV Main Bus as per sample.
Supply of bolted type tension fitting without turn buckle and all accessories for twin ACSR Moose conductor for 132 KV Main Bus as per sample.
Supply of post insulator clamp duly made of LM-6 Alluminium Alloy suitable for 132 KV Post insulator and single panther conductor complete with GI nuts, bolts, spring & washer as per sample.
Supply of PG clamp duly made of LM-6 Allu. Alloy suitable for ACSR Moose to Panther conductor complete with 04 no. 16x75 mm size GI bolts, nuts, spring & plane washer as per sample.
Supply of PG clamp duly made of LM-6 Allu. Alloy suitable for ACSR Moose to Moose conductor complete with 04 no. 16x75 mm size GI bolts, nuts, spring & plane washer as per sample.
Supply of PG clamp duly made of LM-6 Allu. Alloy suitable for ACSR Panther to Panther conductor complete with 04 no. 16x75 mm size GI bolts, nuts, spring & plane washer as per sample.
Supply of 132 KV Tendam Isolator bimetalic terminal clamp made of LM-6 Alluminum Alloy suitable for twin panther conductor complete with GI nut&bolts and washers.
Supply of 02 no. U Bolted Type Single suspenstion fitting assembly suitable for twin ACSR Moose conductors complete with hardware fitting, socket eye, Ball Hook, Yoke Plate, J-Hook etc. as per technical specification as per sample.
Supply of 02 no. U Bolted Type Single suspenstion fitting assembly suitable for ACSR Single Panther conductors complete with hardware fitting, socket eye, Ball Hook, Yoke Plate, J-Hook etc. as per technical specification as per sample.
Supply of spacer suitable for 132/33 KV Bus Bar twin ACSR Moose conductor with 250 mm spacing and duly made of LM-6 alluminum alloy, complete with 12 mm dia HDG Bolts, Nuts, Spring & Plane washer as per technical specification as per sample.
Supply of 132 KV Isolator terminal clamp made of LM-6 alluminum alloy suitabel for single panther conductor complete with GI nut & bolts and washers.
Supply of U Bolt 20 mm dia with double nuts, bolts and washer.
Part "B" Work.
Shorting,counting shifting and loading of galvanized structurel on private vehicle on Electy. Fabrication unit naini Prayagraj.
Safely carriage of galvanized structure from Electy. Fabrication unite Naini to 132 kv S/S Shankargarh. Approx distance 55km. On privet vehical (per truck basis)
Unloading, shorting, shifting & stacking in proper order as per member wise of above structure at 132 kv S/S Shankargarh.
Dismentaling of following structure/ equipments including opening of jumper from equipments and shifting of material from site to store.
145 kv circuit breaker with structure of 40 mva T/F –I &II
145 KV P.I. with structure
De-termination shifting of control cable with proper ferruling of above dismentalled 145 KV CB
Erection of following structure/equipments including their shifting from S/S store to erection site.
Lattice type auxiliary structure
145 kv circuit breaker
145 kv LI/BI with post insulator
145 kv Tandem Isolator with post insulator.
132 kv post insulator
132 kv Control &Relay panel for bus cupler
Laying & Stringing of 132 kv transfer bus bar of single ACSR panther conductor including hoisting of disc insulater tension string with tension fitting (05 section) (01 job per phase per section).
Laying of stringing of 132 KV Jack Bus Bar of ACSR Panther conductor for connectivity 40 MVA T/F-I&II with Transfer Bus in 02 section (01 job per phase per section).
Opening of existing jumper of 132 KV main bus of 132 KV 05 no. line bay and 02 no. 40 MVA T/F Bay, including shifting of jumper from work site to S/S store.
De-stringing & dismantling of existing 132 KV main bus bar of single ACSR moose conductor inclduing de-hoisting of disc insulator, tension string with tension fitting from gantry alongwith shifting the old material etc. from switchyard to store at the sub-station (01 job per phase per section).
Laying & stringing of 132 KV main bus barof twin ACSR moose conductor including hoisting of disc insulator, tension string which tension fitting alongwith shifting of material etc. from store to switchyard (01 job per phase per section)
Fixing of 250mm size spacer between above laid 132 KV Main bus bar conductor of twin ACSR moose conductor.
Jumpering of equipments of 132 KV bus coupler, 40 MVA T/F-I & II & 132 KV 05 no. Line Bays with the help of ACSR Moose/Panther conductor with main bus & transfer bus by suitable clamp of connectors including measuring, cutting, bending, shaping etc. of the conductor as per site requirement.
Laying of following size copper control cable in cable trench from control & Relay panel in control Room to various equipments, junction boxes etc .in switchyard as per cable schedule including shifting of cable drom from store place to work site and back the balance cable to store at the sub station.of bus coupler:-
2cx2.5mmsq
4cx2.5 mmsq
6cx2.5mmsq
Inter connection & termination of various size above laid control cable with bus coupler C&R panel to various equipments C B of 40mva T/F I&II after shifting of C B. with proper ferrule.
Earthing by cutting,strainthening & laying approx 500.0mm below inside Ground & above Ground of following size M.S flate to be provided by the Department for earthing of Main & Aux structure,equipments and cable trenches including Welding with main earth mat and with the object to be earthed including Excavation of earth and its back filling etc:-
Earthing of 03 no 132 kv SF6 CB with 75x10 mm size MS flate
Earthing of Main & auxiliary structure and equipments (LSI/BSI,tandem iso,CT, etc.with 50x6mm size MS flate.
Earthing of cable treanches and junction boxes with 25x6mm size MS flate.
Providing & fixing of Name plate of 02 mm thick aluminium sheets with covering of 3HP retro reflective sheeting of size 300mmx150mm plate to be fixed with the help of nuts & bolts as per sampal.
Providing & fixing of phase plate (R Y B phase of 02 mm thick aluminium sheets of size 5” dia covering of 3M HIP/MDG retro reflected sheet in single piece with all mounting with GI nuts& bolts (01 set = R Y B phase).
Fixing of false ceiling with aluminium work and adjusting hangar (upto 200 mm length) in control room & committee room of 132 KV S/S Shankargarh:-
Providing and fixing of 06 mm diameter GI level adjusting hangers (upto 200 mm length) fixed to roof slabs by means of ceiling cleats made cut of GI flants 40x3 mm diameter 40 mm long complete as per direction of supervision Engineer.
Providing and fixing false ceiling with 12 mm thick plain semi perforated or with design ceiling tiles of BWP type phenol formaldehyde synthetic resin bended pressed particle board confining IS 3078 finished with a coat of aluminium primer on both side and edges and two coats of synthetic enamel paint of approved quality on exposed face fixed to a grid made out of anodized aluminium (with 15 micron anodic coating) T section 35x15x1.5 mm size main runner and cross runner 23.5x15x1.5 mm fixed to main runner placed 600 mm centre to centre both ways so as to from A grid to 600 mm square. The frame work shall be suspended from ceiling by level adjusting hangers of 06 mm diameter M.S. Rod fixed to roof slab by means of ceiling cleats. The suspenders shall be placed 600x1200 mm centre to centre including fixing to the frame with C.P. brace screws and applying a priming coat of zinc chromate yellow primer.
Providing & Fixing of 120 Watt L.E.D. Switchyard Light Luminaries Fittings of Philips / Compton Greaves / Havells make in Single Piece Die Cast Aluminium Alloy Housing with Pot Optics Reflector & Toughened Clear Glass Cover with Frame for Lamp Compartment inlcuding Cable Terminations. The work includes the cost of men, material & T&P required.
Renovation of lighting in control room & committee room of this sub-station by making wiring of L&F 5A with piano key type switches of standard make like Anchor using PVC insulated copper wire of 1.5 sq mm of good quality as per ISI specification and earth wire 0.75 sq mm in casing caping type wiring along with wall & roof including junction boxes fitted with white sunmica base and other material of approved quality for completion of work in all respect. The work includes the cost of men, material & T&P required.
Wiring point for 5A plug socket of standard make like Anchor/Kingla with 1.5 sq mm insulated copper wire and its earth continuity wire details in Sl.No. 20 including the cost of men, material & T&P required.
Wiring point for power 15 A Piano type switch and socket with 2.5 sq. mm insulated copper wire good quality as per specification as approved by Engineer in charge details in Sl.No. 20 including the cost of men, material & T&P required.
Providing and fixing of points for D.C. LED bulb with holder complete in all respect with wiring details in sl. Sl.No. 20 including the cost of men, material & T&P required.
Supply and fixing of wall mounted smart LED 1.5 slimite decorating lighting fixtures fittings with acryclic cover of 16 W of Philips/Crompton Greaves Havell,s/standard make including the cost of men, material & T&P required.
Supply and fixing of decorative recessed Energy Efficient LED fittings of size 600x600 mm of 36 watt syska make including the cost of men, material & T&P required.
Supply & fixing of 2.5 ton split AC (bluestar/carrier make with stabilizer) for control room of 132 KV S/S Shankargarh to make efficient and acurate operation of numerical relays of 132 KV Lines, Transformers & 33 KV Feeders. The work includes the cost of men, material & T&P required.
Supply and laying of 4x2.5 sq.mm PVC insulated and sheeted standard copper wire for Air conditioner indoor as well as out door unit by laying 4x2.5 mm sq. copper make standard by including cost of all material, men & T&P including cost of 4x2.5 mm sq. copper cable (actual length as per site requirement) of standard quality including the cost of men, material & T&P required.
Supply & laying of MS PVC conduct pipe 25 mm including bending, making junction and other associated work as per site requirement.
Marc vision
Hi-tech power transmission
M/s S.S. Refregeration
KARAN SINGH
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .