Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance 12 2 332 21 HILL COLONY OPP SUNRISE SCHOOL MEHDIPATNAM HYDERABAD 500028 | HYDERABAD | HYDERABAD | TELANGANA | 500028 | Admitted-Finance |
| 3 | Admitted-Finance 39 40 DASHMESH MARKET CIVIL GURUDWARA LINE PORT BLAIR 744 101 | PORT BLAIR | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744101 | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
Tender Value
₹44.8 L
EMD Value
₹89,500
Closing Date
16 Dec 2023, 6:00 pmClosed
GE GOLCONDA
GE GOLCONDA LANGER HOUSE OPP MILITARY HOSPITAL HYDERABAD TELANGANA-500 008
SPECIAL REPAIRS TO UG SUMPS AND OHT (GROUTING / CONCRETE) OF VARIOUS SIZES IN MEHDIPATNAM AREA UNDER GE GOLCONDA
2023_MES_628615_1
8728/E8
Open Tender
Civil Works - Others
Item Rate
180 days
HYDERABAD
As Per Tender
9 documents required · 9 mandatory
₹500
GE GOLCONDA
₹89,500
Yes
18 Dec 2023
17 Nov 2023
18 Dec 2023
17 Nov 2023
16 Dec 2023
1 Dec 2023
Amount
M&L for pressure gunniting/shotcreting for columns / beams surfaces of overhead resoirvoir (OHT) including water proofing by Epoxy coating of any size and staging height upto 24.00 metre by using mechanical means and necessary scaffolding complete all as specified and as directed. :- Notes:- Stages for gunniting/shotcreting columns/beam surfaces:- (a) Dismantling/taking down loose /spalling /unsound cement concrete layers average depth 25mm from the Columns/beams and dispose off unserviceable debris and rubbish outside MD land. (b) Preparation of exposed reinforcement (i.e. including cutting of all edges, roughening the smooth surfaces, scrapping out / removing corrosion all loose / scale / rust etc from visible reinforcement by applying rust remover Reebaklens RR (3-4 Sqm per litre) or epoxy coated bonding agent or equivalent of Chemco system / Webac chemical and trimming cleaning the steel reinforcement properly) of beam/columns surfaces. (c) Insertion of additional Reinforcement . (Reinforcement will be measured separtely) (d) Applying two Coats to the exposed reinforcement by ReArm Coat- Zp or equivalent of Chemco system / Webac chemicals on visible reinforcement surfaces to form a continious dry film not less than 80 micron thick a reinforcement epoxy. (e) Gunniting/Shotcrete the damaged portion with cement mortar mixed with Aqua Arm bond latex and then plastering.
M&L for water proofing by grouting & Epoxy coating for wall/floor surfaces of RCC UG Sump/ Semi UG Sump of any size and any height / depth by using mechanical means and necessary scaffolding complete all as specified and as directed. :- Notes:- Stages for water proofing by nozzle grouting & Epoxy Coating wall/floor surfaces:- (a) Dismantling loose /spalling /unsound cement concrete layers from the wall/floor or racking out surfaces and disposed up unserviceable debris and rubbish outside MD land. (b) Cutting of the construction joints in 'V' shaped grooves. (c) Drilling of holes for pressure grouting of 10mm to 15 mm dia., 100 to 150mm deep at the intervals of 350 mm c/c on RCC structural members surfaces in staggered manner in the honeycomb / seepage portions and cleaning of holes by air blower prior to fixing nozzles. (d) Patching the entire 'v' shaped grooves with cement, admixed with quick setting compound . (e) Fixing of PVC nozzles for grouting with quick setting compound admixed with cement. (f) Next grouting is to be done with cement mixture with CEBEX-100 through nozzle by high pressure injection pump incl rendering 15mm thick with CM(1:6). All these operations are made from inside/outside of the reservoir and arrange all necessary scaffolding needed to complete the entire procedure. (g) Water testing of the tanks by filling the tanks with water and for successfully prevention of the water leakage switch over to the next level for expoxy coating. (h) Applying a coat of floor/wall surfaces with cementitious acrylic polymer coat Aqua Arm Topguard. (j) Water to be made empty and a water proofing coating to be made in 2 coats in the inner wall and floor of the tank with water based epoxy Aqua Arm Tank Coat (Potable Water grade).
M&L for water proofing by grouting & Epoxy coating for wall/floor surfaces of RCC Over head resoirvoir (OHT) of any size and staging height upto 24.00 metre by using mechanical means and necessary scaffolding complete all as specified and as directed. :- Notes:- Stages for water proofing by nozzle grouting & Epoxy Coating wall/floor surfaces:- (a) Dismantling loose /spalling /unsound cement concrete layers from the wall/floor or racking out surfaces and disposed up unserviceable debris and rubbish outside MD land. (b) Cutting of the construction joints in 'V' shaped grooves. (c) Drilling of holes for pressure grouting of 10mm to 15 mm dia., 100 to 150mm deep at the intervals of 350 mm c/c on RCC structural members surfaces in staggered manner in the honeycomb / seepage portions and cleaning of holes by air blower prior to fixing nozzles. (d) Patching the entire 'v' shaped grooves with cement, admixed with quick setting compound . (e) Fixing of PVC nozzles for grouting with quick setting compound admixed with cement. (f) Next grouting is to be done with cement mixture with CEBEX-100 through nozzle by high pressure injection pump incl rendering 15mm thick with CM(1:6). All these operations are made from inside/outside of the reservoir and arrange all necessary scaffolding needed to complete the entire procedure. (g) Water testing of the tanks by filling the tanks with water and for successfully prevention of the water leakage switch over to the next level for expoxy coating. (h) Applying a coat of floor/wall surfaces with cementitious acrylic polymer coat Aqua Arm Topguard. (j) Water to be made empty and a water proofing coating to be made in 2 coats in the inner wall and floor of the tank with water based epoxy Aqua Arm Tank Coat (Potable Water grade).
M&L for removing loose plasters and concrete layers from the roof, ceilings, beams and columns etc including all necessary scaffolding and disposing off debris outside of cantonment complete all as specified and as directed.
M&L for Preparation of exposed reinforcement by using rust remover to remove all rust complete all as specified and as directed.
M&L for coating the exposed reinforcement by Re Arm Coat - ZP (Reinforcement epoxy) complete all as specified and as directed.
M&L for layering the old concrete with Re-Arm super bond a solvent free epoxy resin bonding agent which will act as a bonding agent between old and new concrete including necessary formwork, scaffolding and cement etc. complete all as specified and as directed.
M&L for backing the entire surface with concrete mortar prepared with 6mm stone aggregates, sand and cement including necessary formwork, scaffolding etc.complete all as specified and as directed.
M&L for 15 mm thick plastering the entire backed roof/beams/columns/walls mixed with Aqua Arm Bond Latex including necessary formwork, scaffolding and cement etc. complete all as specified and as directed.
Supply only BRC welded wire mesh as additional reinforcement wherever required including necessary fixing arrangement such as nuts & bolts, anchors etc. complete all as specified and as directed.
Supply only chicken wire mesh for plastering of concrete surfaces wherever required incl necessary fixing arrangement complete all as specified and as directed
M&L for complete removal of existing treatment and preparation of old / new plastered surfaces and applying two coat (Base Coat and Top Coat) of exterior weather coat emulsion paint over primer of following brands : (i) Asian Paints - Ultima Protek (ii) Berger Paints - Weather Coat Long Life (iii) Nerolac Paints - Suraksha superior protection for "overhead tanks staging ht upto 24.00 metre" compelete all as directed.
M & L preparation of old decorated surfaces of walls plastered or unplastered by brooming down or steel wire brushing, scrapping down smoke soots, moulds ,moss and efflorecent salts and treading oil and greasy spots etc and applying one coat of white wash to walls .
S&F Rolled mild structural steel Stairs (framed) including stringers, treades, landing, balusters, hand rails etc. in?cluding cleats, brackets, etc. complete.conforming to Fe 410-W (Gde-E) including taking down existing satir all as specified and directed.
M&L preparation of old painted surface of Steel and iron work of any description not otherwise described over 10 cm. width or girth shall include brooming down or steel wire brushing; scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots and applying one coat of synthetic enamel paint complete all as specified and directed.
M&L for mild steel TMT bars 6mm to 8 mm dia and over in reinforcement cut to length, bent to shape required including bending ,cranking and hooking ends and binding with and including MS wire (annealed) not less than 0.9 mm dia complete all as specified.
M & L preparation of new steel surfaces description over 10 cm in width or girth applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as directed.
Taking down water level indicator unit from Over head reservoir/Semi Under ground sump, supply and fix new water level indicator with complete accessories such as copper ball, necessary pully, nylon rope, steel patti duly painted white with marking at every 10cm interval, letter writing of size 15mm width and 100mm long with signal red radium paint and painting of indicator with illumination postal red paint and errected at the height of 3 meter from ground level with necessary angle iron, nut and bolts complete all as specified and as directed by Engr-in-charge.
rahi consultant
VAARAAHEE STRUCTURAL REPAIRS AND WATERPROOFING CONTRACTORS
STANDARD AGENCIES
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .