Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.0 CrAccepted-AOC | ₹8.0 Cr | L1 | Accepted-AOC Being L1 Bidder |
| 2 | L2₹8.4 Cr+₹35.6 L (4.42%)Rejected-AOC | ₹8.4 Cr+₹35.6 L (4.42%) | L2 | Rejected-AOC Not being L1 bidder |
| 3 | L3₹8.8 Cr+₹73.9 L (9.18%)Rejected-AOC ATLANTIS A2 1501 PLOT NO 05 SECTOR 11 NEAR CLOUD 36 GHANSOLI NAVI MUMBAI 400 701 E 97 CWE SUBS BHANDUP | THANE | MAHARASHTRA | 400701 | ₹8.8 Cr+₹73.9 L (9.18%) | L3 | Rejected-AOC Not being L1 bidder |
| 4 | L4₹8.9 Cr+₹89.6 L (11.1%)Rejected-AOC 61 LAALA LAJPAT RAI COLONY BHOPAL M P 462023 | BHOPAL | MADHYA PRADESH | 462023 | ₹8.9 Cr+₹89.6 L (11.1%) | L4 | Rejected-AOC Not being L1 bidder |
| 5 | L5₹9.1 Cr+₹1.0 Cr (12.7%)Rejected-AOC 2 11 SADAR BAZAR DELHI CANTT 110010 | DELHI | NEW DELHI | DELHI | 110010 | ₹9.1 Cr+₹1.0 Cr (12.7%) | L5 | Rejected-AOC Not being L1 bidder |
Tender Value
₹10.1 Cr
EMD Value
₹8.3 L
Closing Date
23 Sept 2024, 6:00 pmClosed
CHIEF ENGINEER, CHENNAI ZONE, ISLAND GROUNDS
HQ CE CHENNAI ZONE ISLAND GROUNDS ANNA SALAI CHENNAI 600 009
ADDN ALTN AND SPECIAL REPAIR TO SELECTED JCOS OR MD ACCN AT MEHDIPATNAM UNDER GE GOLCONDA HYDERABAD
2024_MES_657546_2
89077/E8
Open Tender
Civil Works
Item Rate
720 days
Golconda Hyderabad
As per tender notice and tender documents
7 documents required · 7 mandatory
₹3,000
GARRISON ENGINEER GOLCONDA
₹8.3 L
Yes
23 Dec 2024
9 Sept 2024
28 Sept 2024
9 Sept 2024
23 Sept 2024
16 Sept 2024
Amount
Taking down of old bituminous tarfelt or any other type of roof treatment and cement plaster, removal of the debris to outside MD land, roughening and preparing the surface by cleaning of the roof surface with wire brush to make it free from dust, dirt etc., scrubbinbg down with water to receive new treatment complete all as specified and as directed.
Material and labour for PCC 1:2:4, type B0, using 12.5mm graded stone aggregate mixed with liquid water proofing compound as per manufacturer's instructions as in roof padding to maintain the possible slope and finished the surfaces fair and even all as specified and as directed. Note : Liquid water proofing compound will be measured and paid separately under relevant item.
Material and Labour for 10 mm thick rendering in CM 1:3 mixed with liquid water proofing compound as per manufacturer's instruction on fair faces of brick work or concrete surface finished even & smooth without using extra cement complete all as specified and as directed. Note : Liquid water proofing compound will be measured and paid separately under relevant item.
Material and Labour for water proofing treatment to roofs with five layered APP modified prefabricated membrane as per IS 16540-2017/ IS 16532-2017, matt finish, 3 mm thick and weighing not less than 3.6 kg/sqm reinforced with non woven polyester matt black finish weighing not less than 150 gm/Sqm having softening point not less than 140 degree Celsius, longitudinal tensile strength not less than 300 N/Sqm laid over and including bitumnious primer conforming to IS-3384 applied @ 0.40 ltrs/Sqm bonded with bonding material of blow type bitumen of grade 85/25 heated to a working temperature of 180 degree C and applied at the rate of 1.20 kg per square metre of the surface area, laid with torch application on membrane using gas burner with 100 mm overlap on side lap and end lap as per manufacturers instructions with top most layer of surface finished with two coats of solar reflective aluminium paint @ 0.10 Litre/Sqm per coat etc., complete all as specified and as directed. Note: (i) The work shall be executed through Manufacturer's authorised applicator approved by GE. (ii) The quoted rate is deemed to include the cost of digital photograph and plaster plate as per PS.
Supply only Integral Liquid Water Proofing Compound all as specified and as directed.
Cutting grooves in brick wall, 75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar 1:3 (for water proofing) complete all as specified and as directed.
Taking down cement plaster on brick work or stone walls/cement surfaces etc., including racking out of joint , hacking for key scrubbing down with water etc., and removing debris to outside MD land all as specified and as directed.
Demolition of brickwork or stone/boulder masonry, built in cement mortar with all quoins, arches, pillars, etc but excluding ashlar facings, dressed stone work and precast concrete articles including disposal of the rubbish out off the premises complete all as specified and as directed.
Material and labour for brick work with fly ash bricks, straight or curved on plan exceeding 6 metre mean radius with old size bricks built in CM 1:6 complete all as specified and as directed.
Material and labour for brick work with fly ash bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 complete all as specified and as directed.
Material and Labour for rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6, finshed the surface even and smooth without using extra cement complete all as specified and as directed.
Material and labour for rendering in Cement Mortar 15mm thick in two coats, i.e, in Cement Mortar 1:4, 5mm thick mixed with liquid water proofing compound as per manufacturers' instructions over in Cement Mortar 1:6, 10mm thick on fair faces of brick/concrete surfaces, finished even and fair externally complete all as specified and as directed. Note: Liquid WPC will be measured and paid separately.
Material and labour for rendering 5 mm thick on concrete surfaces of ceiling or soffits of chhajas etc; in CM 1:3, finished the surfaces even and smooth without using extra cement complete all as specified and as directed.
Material and labour for preparing newly plastered wall surfaces of walls and applying two coats of distemper oil emulsion over 2 mm thick cement based wall care putty over alkali resistant primer etc., complete all as specified and as directed.
Material and Labour for preparation of newly plastered surfaces and applying two coats of cement based paint on walls complete all as specified and as directed.
Material and Labour for preparing newly plastered ceiling surfaces and applying three coats of white wash complete all as specified and as directed.
Taking down chowkats (or) frames of any description with shutters (without taking off shutters from the frame) of area not exc.1.5 sqm each along with fittings all as specified and as directed .
Taking down chowkats (or) frames of any description with shutters (without taking off shutters from the frame) of area exc.1.5 sqm not exc 4sqm each along with fittings all as specified and as directed
Supply and Fix 2nd class hardwood, Plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered,put together with glue pinned at joints for doors and windows including treating back of chowkats and holdfasts with tar or coal tar black paint etc., and making good the surfaces etc., complete all as specified and as directed. Note : Holdfasts shall be measured and paid separately.
Supply and Fix factory made Flush shutters 35mm thick solid core solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and as directed.
Supply and Fix 2nd class hardwood factory made 35mm thick glazed and skeleton door shutters, open rebated and prepared to receive glass, gauge etc., without sash bars, edges of framing plain, chamfered, rounded fitted with cut and mitred beads for securing glass etc, size of members as specified in SSR Part 1 section 8 clause 8.24 (a) supplied and fitted to chowkats complete all as specified and as directed.
Supply and Fix 2nd class hardwood, thickness of shutter for windows/ ventilators in 30 mm, Glazed and skeleton shutters, open rebated and prepared to receive glass,gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass,etc.; sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (b);,etc completeall as specified and as directed.
Supply and Fix factory made solid PVC door frame of size 50mm x 47mm made out of 5mm thick plain colour PVC sheet, reinforced with 19mm MS square tube of 19 gauge mitred out at two corners and joined by inserting two Nos of 150mm long brackets of 15mm x 15mm MS square tube inside the drilling 100mm long MS screws using PVC fastener as per manufacturer's instructions complete all as specified and as directed.
Supply and Fix factory made Factory PVC door shutter made solid panel of plain colour, 30mm thick (style) consisting of frame made out M.S tube for top & bottom rails. M.S Frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width struck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail : Panelling of plain colour PVC sheet to be fitted in the M.S frame welded/scaled the stiles & rails with suitalble PVC sheet beading, and joined together with solvent cement, supplying & fixing in the frame at site as per specifications & drawing given in Section 8 of MES Schedule Part-II 2020 as applicable complete all as specified and as directed. Note: Butt hinges, Barrel tower bolts, handles and sliding door bolts shall be measured and paid separately.
Supply and Fix Butt hinges 125 mm size, medium weight cold rolled mild steel and fixed with screws complete all as specified and as directed.
Supply and Fix for Mild steel pressed handles of pattern/design as approved, 150mm size oval type, stove enamelled black, fixed with screws etc., complete all as specified and as directed.
Material and Labour for Mild steel barrel tower bolts, stove enamelled black, with bright bolt and fixed, length of bolt in 200 mm etc., complete all as specified and as directed.
Supply and Fix for Mild steel sliding door bolts, plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed, length of bolt in 300 mm etc., complete all as spd and as directed.
Supply and Fix of extruded aluminium alloy handles fabricated type anodised 125mm all as specified and as directed.
Supply and Fix 150mm Aluminium anodised, barrel tower bolts of extruded section and fixed and fixed complete all as specified and as directed.
Supply and Fix 100 mm long Stainless Steel Butt hinges with stainless steel hinge pin complete all as specified and as directed.
Supply and Fix steel ventilators with top hung shutter including hinges, steel peg stay and painting with one shop coat of zinc chromate primer etc., complete all as specified and as directed. Note : Glass or other filling in panels shall be measured and paid separately.
Supply and Fix 4mm thick figured glass, pin head type andd glazing with wooden beads or oil putty in square not exc. 0.50 Sqm in each pane complete.
Material and Labour for 4 mm thick,Sheet glass,ordinary quality and glazing with oil putty in square not exc. 0.5 sq. m in each pane, etc completed all as specified.
Supply and Fix wire net of any description from metal frame i.e. Steel windows, ventilators, verandah frame by taking out old flat iron flats and removing the same from site and supply and fixing of stainless steel wire cloth 0.36 nominal dia of wire and avg width of aperturre 1.40mm fixed with and incl flat iron fillets 12mm, 3mm with nut bolts incl taking down as directed
Supply and Fix for Mild steel pressed handles, oval type, stove enamelled black, Size of handle in 100 mm, etc., complete all as specified and as directed.
Supply and Fix for Mild steel barrel tower bolts, stove enamelled black, with bright bolt and fixed, length of bolt in 100 mm etc all as specified and as directed.
Supply and Fix of Butt hinges medium weight cold rolled mild steel and fixed in 75 mm complete all as specified and as directed.
Material and labour for preparation of new wooden surface of any description exceeding 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer etc., complete all as specified and as directed.
Supply and Fix Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required:hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; holdfasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165, etc complete all as specified and as directed.
Material and Labour for cement concrete 1:2:4, type B1, using 20mm graded stone aggregate in bed block for hold fasts and coping including necessary form work weathering slighly rounded or chamfered angles and treating and making good the disturbed portion complete all as specified and as directed.
Supply and Fix Mild steel Framed work with ends of bars shouldered and/or riveted,or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165,etc complete all as specified and as diercted by Engineer-in-charge
Supply and Fix Mild steel Framed work with ends of bars shouldered and/or riveted,or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks, for portion framed and hung as a gates, including pintal hinges stops, hand made sliding door bolt and similar work con- forming to Fe.290.Gde-E-165,etc complete all as specified and as diercted by Engineer-in-charge
Supply and Fix Mild steel, plain, black sheet of 1 mm thick , steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required, complete all as specified and as directed.
Dismantling of Asbestos cement sheet (Corrugated/Semi-corrugated etc.) in roof covering, including ridge, valley gutter, wind ties etc complete all as specified and as directed .
Supply and fix Multi rib TM profile (trapezoidal profile) Pre-painted galvalume aluminum zinc coated steel sheet 0.50mm thick (TCT) of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, cut as per site requirement, fixed with self drilling/self tapping screws with EPDM seal as per manufacturer's instructions etc., complete all as specified and as directed.
Supply, fabricate and erection / fixing framed, trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats, Fe 410-W (Gde-E-250) quality-B,etc., complete all as specified and as directed.
Supply and Fix 2mm thick Fiber glass reinforced translucent corrugated sheeting with two corrugations side lap fixed with L-type or J-type or cranked hook bolts in lieu of screw etc in roof, wall etc complete all as specified and as directed.
Material and Labour for applying two coats of synthetic enamel paint on steel & iron surfaces of any description, not otherwise, described, over 10cm width or girth including preparation of new surface & applying one coat of red oxide, zinc chrome complete all as specified and as directed.
Material and labour for coloured Non Skid ceramic tiles of grade B-II(a), 7 to 8 mm thick (square/ rectangular), light coloured group, area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, laid in floors of pattern as approved, set and jointed in neat cement slurry and pointed in white or coloured cement over and including 15 mm thick screed bed in cement mortar 1:6 etc., complete all as specified and as directed.
Material and Labour for coloured Non Skid ceramic tiles of grade B-II(a), 7 to 8 mm thick. (square/ rectanglar) light coloured group, area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, laid in floors of pattern as approved set and jointed in neat cement slurry and pointed with white or coloured cement over and including 15 mm thick screed bed in cement mortar 1:6 complete all as specified and as directed
Material and labour for glazed coloured ceramic tiles of grade B-III, 7mm thick of size 300mm x 200mm / 450mm x 300mm matching to floor tile as approved, fixed on vertical surfaces such as in skirting/dados and risers to steps etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match floor tile over and including 10 mm thick backing coat in cement mortar 1:4 complete all as specified and as directed complete all as specified and as directed.
Material and labour for Machine cut mirror polished kota stone slab 20-25mm thick laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and machine cut polishing with mirror finish and rounding to edges of stone slabs, over and including 15mm thick screed bed or bedding layer of mortar in cement mortar 1:6 as in floors / treads of staircase complete all as specified and as directed.
Material and labour for Machine cut mirror polished kota stone slab 20-25mm thick laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing machine cut polishing with mirror finish as riser of steps, skirting, dado and pillar over and including a backing coat of 10mm thick in CM 1:4 complete all as specified and as directed.
Demolition of PCC in floors or paving of any description n.exc. 15cm thickness (Un re-inforced) below or above GL complete all as specified and as directed.
Material and Labour for 75 mm thick PCC 1:4:8 Type D2 (using 40 mm graded stone aggregate) as in sub bases, floors and pavings etc.,complete all as specified and as directed.
Demolition of Reinforced Cement Concrete of any description and in any position not otherwise specifically provided for including removal of debris to outside MD land all as specified and as directed.
Material and Labour for precast cement concrete 1:2:4, type B1 (Using 20 mm graded granite stone aggregate) as in landings, cover slabs (for manholes etc.) shelves and similar articles with plain faces and set in cement mortar 1:4 including use and waste formwork all as specified and as directed. Note: Reinforcement bars shall be measured and paid separately.
Material and labour for Mild steel TMT bars 6mm to 8mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality conforming to Fe-500D all as specified and as directed.
Dismantling floor hearth or wall tiling including cement mortar bedding, removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed.
Dismantling timber Scantling framed work in fillets, rails, posts, rafters, purlins, etc. not exceeding under 40 sq. cm in section complete all as specified and as directed.
Material and labour for Granite work (of any type) of thickness 22-25mm (of any size) machine cut, Jet Black granite slab, table rubbed and polished, laid over and including 15mm thick cement screed in cement mortar 1:4, bedded and jointed with grey cement slurry and pointed with white cement (1:2) using marble dust and admixture of pigments to match with shade of granite stone including cutting, polishing and rounding to edges of stone slabs etc.,complete all as specified and as directed.
Taking up or down steel tubing 20mm bore and connections for removal to store / taken on credit complete all as specified and as directed.
Supply and fix Galvanised steel water tubing medium grade 20mm bore conforming to IS specifications and ISI marked with all fittings such as bends, tees, unions, elbows, connecting pieces, plugs, sockets etc fixed on walls/ceiling or laid in floors etc., complete all as specified and as directed. Note: (i) Earthwork excavation, returning filling in and removal of surplus soil if required shall be measured and paid separately. (ii) The unit rate quoted shall be deemed to include cost of GI fittings such as bends, elbows, Clamps for fixing on wall, etc.
Taking up or down steel tubing 15mm bore and connections for removal to store / taken on credit complete all as specified and as directed.
Supply and fix Galvanised steel water tubing medium grade 15mm bore conforming to IS specifications and ISI marked with all fittings such as bends, tees, unions, elbows, connecting pieces, plugs, sockets etc fixed on walls/ceiling or laid in floors etc., complete all as specified and as directed. Note: (i) Earthwork excavation, returning filling in and removal of surplus soil if required shall be measured and paid separately. (ii) The unit rate quoted shall be deemed to include cost of GI fittings such as bends, elbows, Clamps for fixing on wall, etc.
Supply and fix in repairs vitreous china wash down water closet squatting pan, Orissa pattern of size 580x440mm with integral foot rest ,colour white with and including P or S trap (excluding flushing cistern & flush pipe), providing lean concrete bedding and making necessary connection to soil pipes and flushing cistern etc.,complete all as specified and as directed.
Supply and fix in repairs PVC valve less, syphonic action type, low level flushing cistern, 10 litre capacity, white, with accessories like inlet, ball valve, float, handle, brackets, PVC flush pipe, over flow pipe etc., including taking down the exiting one complete all as specified and as directed.
Supply and fix in repairs in repairs vitreous china wash basin, white, flat back, size 580mm X 450mm including CI brackets, 32mm dia brass chromium plated waste fittings with long screwed shanks and fly nuts flanged end bedded in red lead cement and other end fixed, 15mm bore pillar tap, cast copper alloy fancy type chromium plated, screwed down high pressure, 32mm Dia Low density polyethylene pipe (LDPE) of pressure rating 6 Kgf/cm2, cutting for & pinning in end of brackets, complete all as specified and as directed.
Supply and fix Stainless steel kitchen sink of over all size 915mm x 460mm with drain board and bowl size 410mm x 355mm x 175mm made out of 1mm thick stainless steel sheet of grade AI SI-304 with plugs, washers, waste coupling and 40mm dia waste pipe of Low density polyethylene pipe (LDPE) of pressure rating 6 Kgf/cm2, fixed over and including CI cantilever brackets or bedding in cement mortar to dwarf wall as required and connecting union to pipe complete all as specified and as directed.
Supply and fix in repairs PVC connection 15mm bore, length 450mm with brass nuts of superior quality complete all as specified and as directed
Supply and fix in repairs Stop valve / angle cock 15mm bore, cast copper alloy, chromium plated conforming to IS with screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for union, complete all as specified and as directed.
Supply and fix in repairs Bib taps 15 mm bore, cast copper alloy, chromium plated, fancy type, with crutch or butterfly handle confirming to IS screwed down, screwed for iron pipes or for brass ferrule, complete all as specified and as directed.
Supply and fix in repairs Brass chromium plated shower rose of size 125mm with swivel joints including shower arm 15mm size, 195mm long with bend of 45 degree with flange for fixing with 15mm dia pipe compete all as specified and directed.
Supply and Fixfor Towel Rail 600mm long of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats. (Minimum weight 190gms), etc complete all as specifed and as directed.
Supply and Fix for Towel Ring of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats (Minimum weight 90gms), etc complete all as specifed and as directed.
Supply and Fix for Shelf of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats (Minimum weight 300gms), etc complete all as specifed and as directed.
Supply and Fix concealed Stop valves cast copper alloy, fancy type, chromium plated screwed down, high pressure, screwed both ends for iron pipe or for unions and fixed 15mm bore complete all as specified.
Supply and fix in repairs Stainless steel Plate rack of size 610mm x 610mm x 254mm with separators and 3 tier shelves made out of 1.00mm thick stainless steel sheet of grade AI SI-304 fixed on wall with rawl plug and chromium plated screws complete fixed all as specified and as directed
Supply and Fix UPVC (SWR) pipes 75mm bore, single socketed in any length with rubber ring joints fixed to walls with suitable size of clamps/ laid in trenches or under floors etc., including demolition and breaking up existing drain pipes and taking out with fittings etc., complete all as specified and as directed . Note: (i) Earthwork excavation, returning filling in and removal of surplus soil if required shall be measured and paid separately. (ii) Clamps for fixing on wall, etc are deemed to be included in the unit rate quoted.
Supply and Fix UPVC (SWR) bends any radius 75 mm dia complete all as specified and as directed.
Supply and Fix UPVC (SWR) bends with access door any radius 75 mm dia complete all as specified and as directed.
Supply and Fix UPVC (SWR) junction single, (Single T) equal or unequal any radius, 75 mm dia, complete all as specified and as directed.
Supply and Fix UPVC (SWR) pipes 110mm bore, single socketed in any length with rubber ring joints fixed to walls with suitable size of clamps/ laid in trenches or under floors etc., including demolition and breaking up existing drain pipes and taking out out with fittings etc., complete all as specified and as directed . Note: (i) Earthwork excavation, returning filling in and removal of surplus soil if required shall be measured and paid separately. (ii) Clamps for fixing on wall, etc are included in the unit rate.
Supply and Fix UPVC (SWR) bends any radius 110 mm dia complete all as specified and as directed.
Supply and Fix UPVC (SWR) junction single, (Single T) with access door equal or unequal any radious, 110 mm dia, complete all as specified and as directed.
Supply and fix in 110mm bore UPVC (SWR) bend any radius with access door complete all as specified and as directed.
Supply and Fix UPVC (SWR) Nahani /Floor trap, 75 mm dia of out let, plain with grating including jointing to waste pipe with solvent and cement concrete type B1 (1:2:4) & including removing old trap and fixing of stainless steel grating in ground shape etc complete all as specified and as directed.
Dismantling / Demolition and breaking of old PVC water tank of capacity 500 ltrs to 1000 ltrs with ball valve laid on RCC roof slab carefully without disturbing to existing roof/wall etc., complete all as specified and as directed. Note : If any damage occurred to existing roof / wall during demolition shall be made good by the contractor at his own and without any cost to department.
Supply and Fix, 1000 litres capacity Rotational Moulded Polyethylene (HDPE) FDA grade materials water storage tanks, three layered (Cylindrical vertical with closed top) screwed lid type conforming to IS: 12701-1996 with manhole lid and suitable locking arrangement including making holes for inlet, outlet, washout and over flow pipes, hoisted and fixed in position as specified in SSR Part -I (2009) etc., complete all as specified and as directed.
Supply and fix Ball valve PTMT with epoxy coated aluminimum rod for 20mm bore pipe, weight not less than 210gms, high pressure with polyethylene high density float and complete screwed for iron pipe all as specified and as directed.
Supply and Fix in repairs UPVC Vent cowl 110mm dia complete all as specified and as directed.
Supply and Fix UPVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement completed all as specified and as directed by Engineer-in Charge.
Material and labour for Anti termite treatment of soil under existing floors using emulsion @ one litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement: 2 coarse sand) to match the existing floors , etc complete all as specified and as directed.
Material and labour treating with ATT chemical along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 Ltrs per linear metre including drilling and plugging holes etc. in apron., etc complete all as specified and as directed.
Material and Labour for 75 mm thick PCC 1:3:6, type C2 (using 40mm graded stone aggregate) in plinth protection laid in alternative bays finished even and smooth without using extra cement including making 10 mm wide grooves to full depth at 3 m interval and at every change of direction and filling the grooves with mixture of bitumen and sand mixed in the ratio of 1:3 by weight and top 10 mm depth sealed with sealing compound grade ‘A’ complete all as complete all as specified and as directed.
Supply and Fix MS helical door spring 300 mm long with roller and roller plate complete all as specified and as directed.
Taking down carefully existing Unserviceable point wiring of any description / type / size of (light/fan/socket/call bell/two way/Power point) on TW batten/ conduit complete including fittings and fixtures such as switches, ceiling roses, shades, brackets, sockets, holders, light fittings, call bells and removing the materials to store for keeping in safe custody for reuse at site or for taking credit including making good the disturbed surfaces of walls/floors/ceilings etc. complete all as specified and as directed.
Material and Labourfor providing point wiring with 1.5 sq. mm (nominal area) single core PVC insulated FRLS unsheathed multi-stranded copper conductor cable (maintaining colour code), 1100 volts grade drawn through in and including non metalic rigid PVC conduit medium grade of appropriate size (ISI Marked) with all accessories concealed in wall / ceiling including continuous earth wire 1.5 Sqmm PVC insulated FRLS unsheathed 1100 Volts multistranded copper conductor connected to common earth and earth dolly including factory made branded modular metal flush boxes concealed in walls and modular white plate covers for mounting of modular switches/ sockets/fan regulators etc complete for one light/ fan /bell point controlled by one oneway modular switches complete all as specified & directed at site. Note : Cutting chases in brick masonry walls/concrete surfaces for concealed conduit wiring and making good the disturbed surfaces shall be measured and paid separately.
All as per ser item No. 100.00 here in before but for one 3 pin socket outlet 5 Amp independent.
All as per ser item No.100.00 here in before but for one 3 pin socket outlet 5 Amp on same board.
Material and labour for Point wiring complete all a specified with 1100 Volts grade 4 sq mm single core PVC insulated FRLSH cable 1100 volts grade with multi stranded copper conductor conforming to IS 694 1990 with ISI marked (for phase, neutral and earth)in and including non-metallic rigid PVC conduit medium grade ISI Marked of minimum size 20mm dia all accessories concealed in wall/ceiling/fixed to roof/truss/columns etc and including factory made branded make embossed galvanised steel metal flush boxes alongwith suitable modular cover plate with frame for fixing modular switches and sockets, and the earth wire to be connected to common earty dolly all as specified and as directed.all as specified and as directed for One three pin modular switch socket 6/16 amps outlet on independent board etc complete all as specified and as directed.
Supply and fix Modular switch, single pole, one way, 6 Amps one module complete all as specified and as directed.
Supply and fix Modular 6A 3 pin universal socket outlet, 2 module complete all as specified and directed.
Supply and fix Modular switch, single pole, one way, 16 Amps one module complete all as specified and as directed.
Supply and fix Modular socket outlet 2-in-1, 6/16 Amps, 2 module complete all as specified and as directed.
Supply and fix ceiling rose, surface mount type, PVC/ Polycarbonate, isolated body with face bakelite 65 x 50mm, 3 terminals complete all as specified and as directed.
Supply and Fix lamp holder insulated body with back plate complete all as specified and as directed.
Supply and Fix modular stepped type electronic fan regulator 220 volts, 100Watt, 2 modules complete all as specified and as directed.
Supply and Fix modular bell push 6 Amps 1 module complete all as specified and as directed.
Supply and Fix Bell electronic 230 volt, AC single pole complete all as specified and as directed.
Supply and Fix 9 W LED bulb of base B22 gear with color temp 6500K complete all as specified and as directed.
Supply, fix, test and commissioning of Wall mounted LED tube light fittings1x22 Watts, 230 Volts Decorative ultra slim aluminium LED lighting fixture with high lumen output, environmental friendly, energy efficient with all accessories, prewired all as per Cat No.LHEXBLP7PN1W022 of Havells or techno-commercially equivalent of other specified makes fixed on surfaces of wall or ceiling with necessary hanging/fixing arrangements and connecting of flexible wire twin core from ceiling rose to fitting drawn through and including flexible conduit etc., complete all as specified and as directed.
Supply and FixLED light fitting 1x9W/ 1X10W bulkhead luminaires including LED light driver all as per Cat No. RUGBYGENXFTS10WLED865SSYMB OPC of Havells or technocommercially equivalent of other specified makes fixed on surfaces of wall or ceiling with necessary hanging / fixing arrangements and connecting of flexible wire twin core from ceiling rose to fitting drawn through and including flexible conduit etc.,complete all as specified and as directed.
Supply, fix, test and commissioning of new generation energy saving and environment friendly long life 35Watts LED security light fitting made up of cast aluminium housing with high power led as lighting source and lens embedded PC cover as diffuser having top opening seperate driver compartment with IP66 protection and impact resistance of IK0 suitable for operation on AC single phase 220-240 Volt, 50 Hz supply all as per Cat No.ENDURASUNDOWNSL35WLED765PASYBOPC of Havells or techno-commercially equivalent of other specified makes with all accessories three run of 1.5 Sqmm copper conductor cable drawn through flexible conduit from ceiling rose to fitting etc including lamp bracket alongwith GI medium grade tube of 40mm dia, 1.5 metre long bend to shape 120 degree and 2 Nos of MS clamp 25 x 4mm of required length/size including nuts nd bolts with one coat of red oxide & two coats of silver mtallic paint fixed complete with impact and corrosion resistant paint., complete all as specified and as directed.
Refixing of serviceable LED fittings as retrieved from taking down schedule Item No.99 here-in-before of any wattage, type and make with all accessories internally prewired and connecting up with twisted flexible PVC copper conductor cable of 23/0.0076 from ceiling rose all as specified and as directed.
Supply and Fix factory made, distribution board (MCB DB), IP 43, SPN, 12 way, 240 Volts, horizontal type, double door, semi flush type made out of 1.2mm thick CRCA sheet metal, duly powder coated and conforming to IS 8623 fitted with suitable copper bus bar, neutral links, blanking plate etc., all as per Cat No.DHDPSHODPW12 of Havells or or techno-commercially equivalent of other specified makes, concealed and fixed flush to wall and making good the disturbed surfaces c, fixed on wall including connecting, testing and taking down the existing DB with MCB and MCBs etc., complete all as specified and as directed. Note :- (i) The unit rate quoted shall be deemed to include the cost of cutting chases into walls for concealing MCCB DB and making good the disturbed surfaces with cement work and finishing the surfaces to match with the existing surface. (ii) Incomming MCCB and Outgoing MCBs shall be measured and paid separately.
Supply, fix, connecting and testing MCB, Single Pole (SP), 6-32 Amps, 240 volts of rupturing capacity 10kA, 'C' series all as per Cat No.DHMGBSPF006-032 of Havells or techno-commercially equivalent of other specified makes complete all as specified and as directed.
Supply, fix, connecting and testing MCB, Single Pole Neutral (SPN), 40 Amps, 240 volts of rupturing capacity 10kA, C series type all as per Cat No.DHMGCSNF040 of Havells or techno-commercially equivalent of other specified makes complete all as specified and as directed
Material and labour for Earthing complete with galvanized steel earth plate electrode of size 600mm x 600mm, 6.0mm thick burried directly in ground (earth pit not less than 2.25m deep below normal ground level) with top edge of plate not less than 1.5m below normal ground level, surrounded from all sides by 15 cm thick packed layer of charcoal dust and common salt, filling in alternate layer and earth plate connected to galvanized iron (GI) earth lead wire 4 mm dia as earthing conductor by means of bolts, nuts, check nuts and washers of galvanised iron or steel including 15mm bore light grade GI protection pipe up to 7.5 meter long for GI earth wire all as shown in electrical plate No.3 of MES Schedule (Part I) (2009) connected to earth test point/ main switch/ DB testing on completion all as specified including PCC (1:3:6), type C-1 pit with 50mm thick precast cover of size 540mm x 540mm in RCC (1:1.5:3), type A-1 reinforced with 12mm dia MS bars @ 150 mm c/c both ways with lifting hooks made out of 12mm dia MS bars, wire mesh funnel with watering pipe 20mm dia medium grade, as specified including necessary excavation and earth work in any type of soil etc., complete all as specified and as directed.
Material and labour for Earth continuity conductor or main earthing lead of 4mm dia galvanised iron or steel wire including GI protection pipe light grade 15mm bore fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc.complete all as specified and as directed. Note:- Earth lead and GI Protection pipe provide beyond 7.50 metre in earthing only shall be measured against this item.
Supply and fix 10 sq mm twin core weather proof aluminium conductor cable Suspended with No.8 SWG GI wire from Pole to service bracket & then to meter complete all as specified and as directed.
Supply and fix service bracket made out of 40 mm dia GI pipe, light grade, bend to shape required and fixed on wall/pole with suitable clamps and other accessories including taking down the existing unserviceable brackets etc., complete all as specified and as directed.
Supply, fix, test and commissioning of Wall mounting fan 400mm with all fixing arrangement all as per Model Accelero HS of Havells or techno commercially equivalent of other specified makes, connecting up including provn of three core flexible copper wire of suitable size from ceiling rose to fan all as specified and as directed.
Disconnecting the electric supply and taking down ceiling fan of 1200/1400mm sweep from any height, sealing cable end, dismantling blades and removing fan and blades and deposit to MES store etc., complete all as specified and as directed.
Hanging/Fixing of ceiling fan and connecting up including provision of cable from ceiling rose or connector to fan complete all as specified and as directed.
Supply, install, testing & commissioning of Exhaust fan, metal body with automatic back shutter louvers 230 mm sweep, 1400 / 1350 RPM or more, Air Delivery not less than 510 Cum/Hour, single phase, 240 Volts, AC, 50 Hz all as per Ventil Air - DSP of Havells or techno-commercially equivalent of other specified makes including cutting hole in to the wall / existing window / ventilator etc., and making good the disturbed surfaces and connecting up complete including provision of cable 3/2 core of suitable size from ceiling rose to fan in flexible hose including taking down the old unserviceable exhaust fan etc., complete all as specified and as directed. Note :- The unit rate quoted shall be deemed to include the cost of making hole in walls (RR Masonary or brick wall of any thickness)/other surfaces, making good the disturbed surfaces including any framework/cement work/wood work/welding work etc. required for proper fixing of the exhaust fan and matching to the existing surface.
Taking down and refixing energy meter of any type complete all as specified and as directed.
Cutting chases, pinning in making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings steps, cills, sunshades,shelves, lintels,etc, and cutting chases for concealed water tubing or concealed conduit wiring etc and making good cutting not exc 10 cm grith complete all as specified and as directed
Supply and fix Electric storage water heater (Geyser) of capacity 25 litres, BEE 5 Star rated, 2 kw, vertical type with tank made of ultra thick super cold rolled steel plates Feroglas dry powder coated, 800 glass coated heating elements (Shock proof and hard water proof) and powder coated metallic body conforming to IS:2082 all as per Cat No.Puro Turbo Dx of Havells or techno-commercially equivalent of other specified makes including drilling holes into the walls, provision of 2 Nos of 450 mm long Hot & cold PVC connections , 4 Nos of suitable size anchor bolts, nuts and washers, connecting up electrical and water supply lines including necessary insulation for hot water pipes, testing, commissioning and making good the disturbed surfaces etc.,complete all as specified and as directed .
Material and Labour Cutting the existing 15/25 mm GI pipe and inserting suitable GI Tee incl necessary threading, union etc complete all as specified and as directed.
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr depth for laying of cables, pipes, laying of poles in trenches and getting out in soft/loose soil complete all as directed and specified.
Returning, filling including spreading, levelling, watering and well ramming in layers not exceeding 25 cms thick complete all as all as specified and directed.
Removal of surplus soil to a distance not exceeding 50 mtrs and depositing where directed at a level not exceeding 1.5 mtrs above from the starting point, spread, levelled uniformly in layers not exceeing 25cm each complete all as all as specified and directed.
R. Wadhumal and Sons (BID ID -3101081)
Shree Construction Co. (BID ID -3097516)
SHREE KRISHNA INFRASTRUCTURE (BID ID -3103769)
Megha Construction Co. (BID ID -3108610)
Sai construction & services (BID ID -3108587)
M/s Imperial Coastal Infra (BID ID -3107697)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
151870512.pdf
Tender Document • 0.60 MB
151870518.html
Tender Document • 0.06 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .