GE NORTH UDHAMPUR
GE NORTH UDHAMPUR
GE U(N) 65 2022 23 REPAIR MAINT OF SEWAGE TREATMENT PLANT DG SET MCCB DB SOLAR WATER HEATER EARTH POINT AND MISC EM EQPTS UNDER GE(N) UDHAMPUR
2022_MES_571968_1
GE/U(N)/65/2022-23
Open Tender
Civil Works
Item Rate
180 days
GE NORTH UDHAMPUR
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE NORTH UDHAMPUR
₹90,000
Yes
30 Mar 2023
29 Dec 2022
28 Jan 2023
29 Dec 2022
26 Jan 2023
12 Jan 2023
Amount
Dismantling,taking down,opening and inspecting of the complete solar panel, streel tank/PVC tank and pipe line,cleanig the same with rectifying the leakages of line ,testing complete and making leakproof with replacement of the following unserviceble parts :-
(a) S&F hot and cold badly rusted/broken/damged pipe from hot water tank to collection assembly complete 15mm dia with fixing clamp etc.
(b) S&F inreplacement rubber gasket for flat collector plate of solar water heating system.
(c) S&F in replacement insulation of out going hot GI pipe of solar water heating system.
(d) End cap stainless steel/aluminium with rubber gasket as per existing size
(e) Float valve 20/25mm dia
(f) S&F PVC connection pipe from cold water tank to solar panel with suitable size of clamp
Servicing of solar water heater system with filling anti freeze solution / polycarbonate glycol foul collector panel complete as per manufactor specification complete 350 Ltr capacity including fixing of all spare parts as required to be replacement and testing of solar water heating system complete all as directed by Engineer.in-charge.
Replacement of old unserviceble butterfly gate vavle 40/80 mm dia with all fixing arrengement
M&L for liquid glycol for removing of rusting and avoid to depositing snow inside the pipe line of plant complete all as directed by Engineer.in.charge.
Taking down complete existing earthings alogwith earth lead,strip and GI pipe etc complete all as specified and directed
M&L Earthing complete with using copper plate 60×60cm ×3.15mm thick electrode and 20×3.15 mm copper strip as earthing lead , buried directly in ground (earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to required 20x3mm copper strip by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No-5 of MES Part-1 fixed in replacement including testing on completion including the material and labour of the following :- (a) Excavation and earth work for drilling hole for electrode in any type of soil. (b) PCC Pit in cement concrete 1:2:4 type B-1. (c) Precast RCC cover with suitable handle 40mm thick in PCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than 1.87 Kg/Sqm. (d) Funnel with watering pipe of GI protection pipe 5 mtr long for protection of earthing lead from mechanical injury or tempering. (f) Requisite quantity of common salt and charcoal. (g) Testing of Earthing. Note : (a) On testing after completion of earthing, if the desired earth resistnace is not obtained, the earthing will be done by the contractor at his own risk and cost to the entire satisfaction ot the engineer incharge. (b) The contractor shall quote his rate considering taking down cost of existing unserviceable earthing.
Taking down complete existing earthings earth lead/strip of any type/size and acomplete all as specified and directed
M&L for refixing of earth continuity conductor copper strip 20mm x 3.15mm/32mm x 6mm with saddles and fixing screws etcor main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc complete all as directed by Engineer-in-charge.
S&F earth continuity conductor copper strip 20 mm x 3.15 mm with saddles and fixing screws etc or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc complete all as directed by Engineer-in-charge.
S&F earth continuity conductor aluminium strip 32 mm x 6 mm with saddles and fixing screws etc or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc complete all as directed by Engineer-in-charge.
S&F earth continuity conductor aluminium strip 25 mm x 3mm with saddles and fixing screws etc or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc complete all as directed by Engineer-in-charge.
M&L for taking down air termination, single pointed, copper rod any type / size/ lenght complete all as directed by Engineer in charge.
S&F Air termination, single pointed, copper rod 12mm dia and 300mm long fixed on 40 mm dia 1 mtr long GI pipe,light gradeinculding provision of base and fixing by means of nuts,bolts and washres etc complete all as directed by Engineer.in.charge.
S&F Air termination, single pointed, copper rod 12mm dia and 300mm long complete all as directed by Engineer.in.charge.
S&F Air termination, single pointed, aluminium rod 12mm dia and 300mm long complete all as directed by Engineer.in.charge.
M&L for refixing of air termination rod of any type /size/length on any location retieved from item No 17 above by providing new fixing arrenngement such as clamps,nuts,bolts,washers etc complete all as directed by Engineer-in-charge.
Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hexagonal head screw complete all as directed by Engineer-in-charge.
Fixing only test point terminal box made out of gun metal or phosphorus bronze size 75 x 75 x 25 mm drilled and screwed including 3 Nos 8 mm dia 25 mm long hexagonal heads screw, complete all as specified and directed
S&F earth continuity or main earthing lead fixed to wall or reccess or chases or buried in ground or drown in conduit/pipe or fixed to poles or any others indicated situation for loop earthing etc as required of size 25x4 mm galvanised strip complete all as specified and as directed
Taking down old unserviceable test point of any type, size and location complete all specified and directed
Testing existing earthing pits with suitable earthing testing equipment (earth tester) dully calibrated for checking their serviceability in consultation with user and submission of reports for repairs and rectification (to be measured separately under speciific items of sch) up to the satisfaction of the engr in charge. Note:- one report prior to execution of work one report after execution of work.
M&L for 40 mm dia steel tube (light grade) galvanised with fittings laid in trenches/wall/roof for protection of earthing/lighting strips for crossing the roads/fixing on walls etc complete all as sepecified and directed
M&L for framed work with 2 mm thick MS sheet of size (20x15) cm and angle iron 25x25x3 mm, 50 cm long framed with shape of "T" including necessary welding earth work, PCC block (20x20x20) cm along with painting/marking of location , erth pit No, testing on , result and allied work complete all as specified and driected by engr in charge. Note:- PCC and earth work measured & paid separately under respective items
Opening,Examining and checking complete the DG set 15 KVA sielence feature ,repairing / overhauling with replacing the un serviceable parts as per exiting size and capacity including greasing,servicing and testing complete all as directed by Engineer in charge. (Note –Spare Parts will be paid separately) .
Supply and fixing spare parts of DG SET 15 KVA (a) Diesel filter (Primery/secondry)
(b) Oil filter
(c) Crank case /sump gasket
(d) “O” ring
(e) Oil seal
(f) Fan belt
(g) Alternator for charging of battery
(h) Air cleaner
(j) Cut-Out
(k) Battery coil Ignition switch
(l) AMF panel of DG set complete as per existing size and capacity
(m) Engine oil 10 W 30
Taking out F I P assembly from Gen Set 15 KVA sielence feathure and over hauling /calibration including replacement of burnt out/unserviceble parts such as Gas kit set drive shaft techno meter pump kit,bearing ,weight carrier regular all "O" rings sims e.t.c. and re-fixing FIP at Existing place to D G Set at various pump house complete all as directed by Engineer in charge.
Dismantaling of self starter from Gen Set 15 KVA taking into workshop or repair including replacement of bush pinion carbon bruses ,gear terminal plate, connected plate, thrust washer and re-assumbling and testing complite and fixing at existing place all as directed.
Dismentling of radiator for DG Set of cap.15 KVA and transporting to work shop for over hauling /servicing including cleaning with appropriates chemicals and welding of fins /tubs complete all as directed.
M&L for coolant as reqiured grade and type to top up the entire cooling system of DG set complete all as specified and directed.
S&F radiator rubber hose along with holding clamp as per required size and lengthof DG set complete all as specified and directed.
Excavation in trenches n.exc 1.5 mtr depth and n.exc 1.5 mtr in wide in soft/loose soil including out for fixing T shapes MS sheet and taking out unserviceable eathing pit chamber etc complete all as sepcified and directed
Excavation over area n.exc 1.5 mtr deep in soft/loose soil and getting out complete all as specified and directed
Returning filling in including sprading leveling, watering well ramming in layers n.exc 25cm thick in soft/loose soil complete all as specified and directed
Removing of surplus soil to a distance n.exc 50 mtrs and deposited where directed to a level n.exc 1.5 mtrs above the starting point complete all as specified and directed
M&L for cement concrete 1:3:6 type C2 using 40 mm grade stone aggregatee in foundation filling and mass concrete complete all as specified and directed
M&L for electric/gas welding to any type of strip at any location complete all as specified and directed
M&L for painting with two coats of synthetic enamel paint on surgace of any description over 10cm in width or girth not other wise described
M&L for writing letters or figures (Block, Roman, Italic or Indian) n.exc 30 cm high complete all as specified and directed
M&L Earthing complete with galvanised steel earth plate electrode 60x60cmx6mm thick, buried directly in ground (earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No-5 of MES Part-1 fixed in replacement including testing on completion including the material and labour of the following :- (a) Excavation and earth work for drilling hole for electrode in any type of soil. (b) PCC Pit in cement concrete 1:2:4 type B-1. (c) Precast RCC cover with suitable handle 40mm thick in PCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than 1.87 Kg/Sqm. (d) Funnel with watering pipe of GI protection pipe 5 mtr long for protection of earthing lead from mechanical injury or tempering. (f) Requisite quantity of common salt and charcoal. (g) Testing of Earthing.
Earth continuity conductor or main earhing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4mm dia galvanised iron or steel wire complete all as specified and directed
Disconnecting electrical connection and taking out elect motor and transporting to workshop, opening elect motor 3/5HP cleaning slots and rewinding of elect motor with new supper enameled copper wire best quality of appropriate size and quantity to obtained required resistance, replacement of worn-out suitable size bearing, assembling the same and fixing at its original site as required by Engineer-in Charge including commissioning, testing complete
Disconnecting electrical connection and taking out elect motor and transporting to workshop, opening elect motor 3/5HP cleaning slots and rewinding of elect motor with new supper enameled copper wire best quality of appropriate size and quantity to obtained required resistance, replacement of worn-out suitable size bearing, assembling the same and fixing at its original site as required by Engineer-in Charge including commissioning, testing complete
Disconnecting the defective/burnt electric induction motor & dismantling from the foundation, shifting to workshop opening checking for defects varanising, drying, greasing bearing, insulating the terminals connecting etc incl carrying out minor repair (winding will be paid separeatly complete all as specified and directed
Rewinding the electric induction motor of capacity 1 HP suitable to run on 415V, AC, 50Hz supply with copper enameled copper wire of suitable gauge/size including proper insulation and making connection to the terminal plate complete all as specified and directed
Disconnecting the non clog pump and dismantling from the foundation, shifting to workshop opening checking for defects parts, greasing, bearing etc incl carrying out minor repair complete all as specified and directed
Disconnecting the sullage water pump and dismantling from the foundation, shifting to workshope opening checking for defects parts, greasing, bearing etc incl carrying out minor repair complete all as specified and directed
Disconnecting the air compressure and motor dismantling from the foundation, shifting to workshop opening checking for defects parts, greasing, oiling bearing etc incl carrying out minor repair complete all as specified and directed
Rewinding the air compressure and motor of capacity 5 HP suitable to run on 415V, AC, 50 Hz supply with copper eneameled copper wire of suitable/size including proper insulation and making connection to tbe terminal plate complete all as specified and directed
Supply and fix VTPN MCCB Double door Distribution Board 04 way 415 volts grade IP 43 Protection Grade with provision for (MCCB) as incomming and Three/single phase (TP/SP) outgoings, complete with insulated bus bar arrangement fixed flush to wall complete including connections should be provide with necessary reducer lugs all as specified and directed by Engr-in-charge. Make : C&S Cat No:CSDBMCCB100DD04IP43S/ Standard Cat No: DSDLVDRBAOFO04/ Indo Asian Cat No : 811888
S & F in repair Thermal magnetic MCCB 4 pole 63 Amps 415 Volts 16 ka INCLUDING MAKING NECESSARY ARRANGEMENT all as specified and directed by engineer in charge for MCCB DB.Make C&S Cat No: CSC2N4/ IndoAsian Cat No: 830022/ or equivalent makes to Standard
S & F in repairThermal magnetic MCCB 4 pole 100 Amps 415 Volts 16 ka INCLUDING MAKING NECESSARY ARRANGEMENT all as specified and directed by engineer in charge for MCCB DB.Make C&S Cat No: CSC2N4/ IndoAsian Cat No: 830022/ or equivalent makes to Standard
S & F in repair Thermal magnetic MCCB 4 pole 125/160 Amps 415 Volts 16ka INCLUDING MAKING NECESSARY ARRANGEMENT all as specified and directed by engineer in charge for MCCB DB.Make C&S Cat No: CS3A4/ IndoAsian Cat No: 830095 / or equivalent makes to Standard
S&F in replacement single pole and neutral sheet steel powder coated distribution board for MCBs fitted with bus bar neutral link Earth bar and din rail suitable for use on 240V, 50Hz supply double door SPN DB system 4 Way all as specified and directed by engineer in charge. Make : C&S Cat No:CSDBSPNDD08/ Standard Cat No: DSDNSHODXW08/ Indo Asian Cat No : 810321
S&F in replacement single pole and neutral sheet steel powder coated distribution board for MCBs fitted with bus bar neutral link Earth bar and din rail suitable for use on 240V, 50Hz supply double door SPN DB system 8 Way all as specified and directed by engineer in charge. Make : C&S Cat No:CSDBSPNDD08/ Standard Cat No: DSDNSHODXW08/ Indo Asian Cat No : 810321
S&F in replacement single pole and neutral sheet steel powder coated distribution board for MCBs fitted with bus bar neutral link Earth bar and din rail suitable for use on 240V, 50Hz supply double door SPN DB system 12 Way all as specified and directed by engineer in charge. Make : C&S Cat No:CSDBSPNDD12/ Standard Cat No: DSDNSHODXW12/ Indo Asian Cat No : 810323
S&F in repair connection and testing 'C' series SPN MCB 40 to 63 Amp 240V, 50Hz, 10kA for lighting and other domesitc loads incl necessary copper lugs etc all as specified and as directed by engineer incharge. Make C&S Cat No: CSMBS2C40/ IndoAsian Cat No: 810078/ or equivalent makes to Standard
S&F in repair 'C' series MCB SP6-32 Amps. Make C&S Cat No: CSMBS1C6 to CSMBS1C32/ IndoAsian Cat No: 810078/ or equivalent makes to Standard
S&F in repair 'C' series MCB SP 40 Amps. Make C&S Cat No: CSMBS1C40/ IndoAsian Cat No: 810060/ or equivalent makes to Standard
m/s shanti trading company
DEV RAJ MAGOTRA
JAI JAGDAMBAY ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .