Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.1 LAccepted-AOC WZ 250 B 2 GALI NO 08 SADH NAGAR I PALAM COLONY NEW DELHI 110045 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110045 | L1 | Accepted-AOC Being lowest and competitive | |
| 2 | L2₹14.7 L+₹2.4 L (19.1%)Rejected-AOC | L2 | Rejected-AOC Neither lowest and competitive | |
| 3 | L3₹15.5 L+₹3.1 L (25.2%)Rejected-AOC WZ143 A 7 A S 4 43 GALI NO 2 OLD MAHABIR NAGAR NEW DELHI 110018 | NEW DELHI | NEW DELHI | DELHI | 110018 | L3 | Rejected-AOC and competitive |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
1 Sept 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (Central) Delhi Cantt
GE (Central) Delhi Cantt
CLEANING AND REPAIR OF SEWAGE LINES AND MANHOLES AND REPAIR TO EXTERNAL RAIN WATER DRAIN COMMON ARREAS MISC REPAIR WORK OF OLD APS COLONY AND NEW APS COLONY SIGNAL ENCLAVE AND OTHER ADJOINING AREAS OF AGE B/R II (CENTRAL
2020_MES_367369_1
GE/C-41/2020-21
Open Tender
Civil Works
Item Rate
180 days
GE (Central) Delhi Cantt
As per NIT
9 documents required · 9 mandatory
₹500
GE (Central) Delhi Cantt
₹30,000
Yes
14 Oct 2020
7 Aug 2020
3 Sept 2020
7 Aug 2020
1 Sept 2020
20 Aug 2020
7 Aug 2020 - 20 Aug 2020
60 days
Amount
Cleaning of sewage system incl WCs, WHB, bottle traps Nahani and floor traps soil/waste pipe running on external walls of building incl junctions manholes of any description and sewage lines of all sizes upto the final drop out let into septic tank/soak well of central sewage in running/flowing without disturbance and removing all types of blockages of any description in any situation manually and disposal off of the sludge/waste materials out side defence land the required man power for the same in the area of Signal Enclave (Md accn and all types of Accn) complete all as directed and as specified by Engineer-in-Charge
All as per item No.1 hereinbefore but in the area of APS Colony omplete all as directed and as specified by Engineer-in-Charge
Dewatering/desludging of Manholes upto 3.00m deep cleaning of all sludge, silt residue of both organic and inorganic nature by manual labour or by mechanical scrappers etc and disposal off the same out side the defence area all as directed incl dumping the material to any depth omplete all as directed and as specified by Engineer-in-Charge
Mechanically used high pressure Super Sucker Machine capable of Air lifting of dense sludge like muds, slurry, small stones, debries, grits etc from sewer lines/Manholes thorough vaccum mode and capable of Jetting sewer lines of any dia. The machine shall be used by the contractor as per direction of Engineer-in-Charge as on required basis. Job shall be completed to the entire satisfaction of GE. (For Signal Enclave Area). Note:- Rate quoted are for the whole day that i.e. 8 hrs of Super Sucker Machine omplete all as directed and as specified by Engineer-in-Charge.
All as per item No.3 above but in the area of Old APS Colony and New APS Colony etc omplete all as directed and as specified by Engineer-in-Charge.
M&L for cutting roads depth of 450mm thick (Max)and making good the existing premixed surace incl supply of extra quantities of materials i.e. aggregate, moorum, screening materials,red bajri and the top layer shall be laid with 25mm thick readymade premix bituminous carpet by using brand of M/s CATs of Make INSTANT PATCH ( Instant Road Patch Repairing Premix) or equivilant laid as per the manufacturers instructions all as specified and directed. Note : The Instant Road Patch Repairing Premix shall be measured and paid separately by supply only item.
Supply only Instant Patch Pothole Premix of 25.00Kg/Bag omplete all as directed and as specified by Engineer-in-Charge
Excavation in trenches n exc 1.5m wide and n exc 1.50m in depth for foundation etc and getting out in hard/dense soil omplete all as directed and as specified by Engineer-in-Charge
Excavation in trenches exc 1.5m wide and n exc 3.00m in depth for foundation etc and getting out in hard/dense soil omplete all as directed and as specified by Engineer-in-Charge. Note : For Item No 7 & 8 If any UG Cables, Pipes are damaged during excavation,entire cost for restoration will be borne by the contractor
Returning filling in, incl spreading levelling watering and well ramming in layers n exc 25cm (after the pipes have been laid and tested) in soft/loose soil omplete all as directed and as specified by Engineer-in-Charge
Removing excavated material exceeding 1.00KM and n.exc 1.50 KM depositing where directed at a lavel not exceeding 1.5m above the starting point, soil omplete all as directed and as specified by Engineer-in-Charge
Taking down cement plaster on brick walls built in cement mortar including raking out joints, hacking for key, scrubbing down with water etc omplete all as directed and as specified by Engineer-in-Charge
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specially provided for omplete all as directed and as specified by Engineer-in-Charge
Demolition of brick work built in cement mortar incl all quoins, arches, pillars etc omplete all as directed and as specified by Engineer-in-Charge
M&L for providing precast cement concrete coping with plain fair faces B1, 1:2:4 using 20mm graded stone aggregate and set in CM 1:4 omplete all as directed and as specified by Engineer-in-Charge
M&L for brick work with sub class 'B' bricks old size bricks strainght or curved on plan exc 6m mean radius built in CM 1:6 omplete all as directed and as specified by Engineer-in-Charge
All as above item No.15 above but excep bricks
M&L Cement concrete 1 : 4 : 8 type D2 using 40mm graded crushed stone aggregates incl packing under and haunching against the sides for 150mm internal dia SG SWG pipes after they are laid and tested omplete all as directed and as specified by Engineer-in-Charge
All as per ser item No 17 here-in-before but for 200mm internal dia Salt glazed stoneware pipes omplete all as directed and as specified by Engineer-in-Charge.
Supply and laying, DWCPE (SN4) pipes of 150mm Intrnal dia incl snap fit coupler, bends, Tees, etc and filling of coarse sand/gravel with 100mm bedding and sides for overall width and sides of the pipes covered incl testing and laid in trenches to a level on gravels/sand bed etc omplete all as directed and as specified by Engineer-in-Charge
Supply and laying, jointing 150mm internal dia of salt glazed stoneware pipes grade 'A' incl testing and laid in trenches to a level on concrete bed omplete all as directed and as specified by Engineer-in-Charge
All as per item No 20 here-in-before but 200mm internal dia of salt glazed stoneware pipes grade 'A' omplete all as directed and as specified by Engineer-in-Charge.
Supply and laying, DWCPE (SN4) pipes of 200mm Intrnal dia incl snap fit coupler, bends, Tees, etc and filling of coarse sand/gravel with 100mm bedding and sides for overall width and sides of the pipes covered incl testing and laid in trenches to a level on gravels/sand bed etc omplete all as directed and as specified by Engineer-in-Charge
M&L for rendering 15mm thick on fair faces of brick work or concrete surfaces in CM 1 : 4 mixed with water proofing compound finished even and smooth without using extra cement omplete all as directed and as specified by Engineer-in-Charge (Water proofing compound shll be measure and paid separatelly).
M&L for rendering 15mm thick on fair faces of brick work or concrete surfaces in CM 1 :6 finished even and smooth without using extra cement omplete all as directed and as specified by Engineer-in-Charge
Supply only intergral water proofing compound omplete all as directed and as specified by Engineer-in-Charge
Cutting into existing manholes for connecting new drains making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 or 3/4 section ) in cement concrete 1:2:4 type B1 using 20 mm graded stone aggregate finished smooth and reforming benching as required for 150/200mm dia pipes omplete all as directed and as specified by Engineer-in-Charge
S & F precast plastic fibre reinforced concrete man hole covers" meduim duty " of overall size 1000 mm x 500 mm x 75 to 80 mm factary made ( make - polycrete ) all as specified and directed by Engr - in - charge
All as above item No 26 but for Gully trap cover of size 450x450x50 mm thick omplete all as directed and as specified by Engineer-in-Charge
M&L for hardcore of broken stone of gauge n. exc 63mm deposited, spread and levelled in layers not exc 150 mm thick watered and rammed to a true surface omplete all as directed and as specified by Engineer-in-Charge
M&L 75mm thick PCC (1:4:8) type D2 (using 40mm graded stone aggregate) as in sub base under the interlocking tiles omplete all as directed and as specified by Engineer-in-Charge
Sand filling (sand cushioning) under floors or in foundations including watering and consolidations omplete all as directed and as specified by Engineer-in-Charge.
M&L machine pressed precast concrete interlocking paver block any shape and size conforming to IS 15658-2006 of 60mm thickness M-35 Grade with grey cement and pigment omplete all as directed and as specified by Engineer-in-Charge.
S & F in repairs 110mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints, waste and vent pipes in any length with or without ears, fixed in walls/floors/ trenches etc omplete all as directed and as specified by Engineer-in-Charge
S & F in repairs 75mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints, waste and vent pipes in any length with or without ears, fixed in walls/floors/ trenches etc omplete all as directed and as specified by Engineer-in-Charge
S & F in repairs 100mm dia sand cast Cast iron soil, waste and vent pipes in any length with or without ears, with cement joints, fixed in walls/floors/trenches etc omplete all as directed and as specified by Engineer-in-Charge
S & F in repairs 75mm dia sand cast Cast iron soil, waste and vent pipes in any length with or without ears, with cement joints, fixed in walls/floors/trenches etc omplete all as directed and as specified by Engineer-in-Charge
S & F in repairs Cast iron Bends of 100mm dia (any radius), diminishing pieces or tapers (larger bore measured) etc omplete all as directed and as specified by Engineer-in-Charge
S & F in repairs cast iron Bends of 75mm dia (any radius), diminishing pieces or tapers (larger bore measured) etc omplete all as directed and as specified by Engineer-in-Charge
All as per item No 36 here-in-before but except bends omplete all as directed and as specified by Engineer-in-Charge
All as per item No37 here-in-before but except bends omplete all as directed and as specified by Engineer-in-Charge
M & L for in repairs Stack clamps out of 50 mm by 5 mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof upto G+3 stories for 100 mm dia pipesall omplete all as directed and as specified by Engineer-in-Charge
All as per item No 34 here-in-before but except pipes omplete all as directed and as specified by Engineer-in-Charge
All as per item No 35 here-in-before but except pipes omplete all as directed and as specified by Engineer-in-Charge
S & F in repairs Cast iron floor trap, with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) 100mm outer dia omplete all as directed and as specified by Engineer-in-Charge
S & F in repairs Cast iron floor trap, with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) 75mm outer dia omplete all as directed and as specified by Engineer-in-Charge
S & F in repairs PVC SWR Bends of 110mm dia (any radius), diminishing pieces or tapers (larger bore measured) etc omplete all as directed and as specified by Engineer-in-Charge
S & F in repairs PVC SWR Bends of 75mm dia (any radius), diminishing pieces or tapers (larger bore measured) etcomplete all as directed and as specified by Engineer-in-Charge
S & F in repairs PVC SWR junction single, (Single T) equal or unequal 110mm dia with access door omplete all as directed and as specified by Engineer-in-Charge
S & F in repairs PVC SWR junction single, (Single T) equal or unequal 75mm dia with access door omplete all as directed and as specified by Engineer-in-Charge
S & F in repairs cast iron junction single, (Single T) equal or unequal 110mm dia with access door omplete all as directed and as specified by Engineer-in-Charge
S & F in repairs Cast iron junction single, (Single T) equal or unequal 75mm dia with access door omplete all as directed and as specified by Engineer-in-Charge
M & L for PCC 1:3:6 type C1 (using 40mm graded aggregate) as in surface channels or drains including for forming fair finished drain or channel of any inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc.forming moulds etc omplete all as directed and as specified by Engineer-in-Charge
Note :- Total amount of Sch of credit is Rs 29550.00 as per Sch of credit. Net contract sum shall be total quoted amount of bidder (-) amount of Sch of credit.
a.k constructions
M/S Sunil Steel Works
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .