Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹21.7 LAccepted-AOC | 1 | Accepted-AOC Lowest | |
| 2 | 2₹23.4 L+₹58,021 (2.54%)Rejected-Finance | 2 | Rejected-Finance Higher | |
| 3 | 3₹23.5 L+₹63,381 (2.78%)Rejected-Finance | 3 | Rejected-Finance Higher | |
| 4 | 4₹25.3 L+₹2.5 L (10.8%)Rejected-Finance | 4 | Rejected-Finance Higher |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
27 Jul 2020, 4:00 pmClosed
GE Amritsar
GE Amritsar PIN 143001
REPAIR/REPLACEMENT OF WATER SUPPLY PUMPS AND CONNECTED ITEMS AT OLD AMRITSAR CANTT
2020_MES_356427_1
GE/ASR-14/2020-21
Open Tender
Civil Works
Item Rate
334 days
GE Amritsar
Class E, Category aii
8 documents required · 8 mandatory
₹500
GE AMRITSAR
₹50,000
Yes
12 Aug 2020
29 Jun 2020
28 Jul 2020
29 Jun 2020
27 Jul 2020
14 Jul 2020
Amount
Material and labour for taking out of submersible pump and motor of 50 to 60 HP capacity including flanged column pipes with chain pulley arrangements and engaging sufficient man power to ensure safety of plant as well as working persons including disconnecting of delivery main lines and electric connections and lowering the same including flanged column pipes and reconnecting the delivery main lines and electric connections of the same after completion of repair complete all as specified and directed. Note: Rate shall be inclusive of loading/unloading and transporting to & from workshop.
All as per item No. 01 above but for submersible pump and motor of 35 to 45 HP capacity.
All as per item No. 01 above but for submersible pump and motor of 20 to 30 HP capacity
All as per item No. 01 above but for submersible pump and motor of 7.5 to 15 HP capacity
All as per item No. 01 above but for submersible pump and motor of up to 5.0 HP capacity
Material and labour for dismantling of electric driven submersible pump motor of capacity 50 to 60 HP, taking out the burnt windings, cleaning and washing of slots and rewinding the same with water resistant copper winding wire of existing gauge and quantity ( as per original manufacturer design) including replacement of all damaged parts such as motor bush, thrust bearing, rotor filling, pump sleeves, CI impeller, pump bush, efficiency ring, neck ring, insulating materials such as insulating sheets insulating paper (Class "F" Make : EUROTHERM or as approved by Engineer-in-charge ), insulating heat resistant sleeves, sealing compounds varnish etc and reassembling the motor complete all as specified and directed. Note :- (i) Winding wire will be measured and paid separately under relevant items. (ii) The contractor will furnish six months warranty against any kind of defect for the repair carried out after the date of installation.(iii) Replacement of existing burnt submersible cable for connection of suitable size min 3 mtr each length from motor included in above quoted rates.
All as per item No. 06 above but for submersible pump and motor of 35 to 45 HP capacity
All as per item No. 06 above but for submersible pump and motor of 20 to 30 HP capacity
All as per item No. 06 above but for submersible pump and motor of 7.5 to 15 HP capacity
All as per item No. 06 above but for submersible pump and motor of up to 5.0 HP capacity
Supply only in replacement of enamelled copper winding wire best quality as directed by Engr-in-charge for winding of centrifugal horizontal/submersible motors , complete all as specified and directed.
Dismantling of electric driven centrifugal horizontal pump motor of 05 to 15 HP capacity taking out the burnt windings cleaning and washing of slots and rewinding the same with enamalled copper winding wire of existing gauge and quantity ( as per original/ manufacturer design )including replacement of all damaged parts such as shaft filling, ball bearing, pump impellers,gland piece, pump bush, pump coupling, insulating materials such as insulating sheets insulating paper ( Class "F" Make : EUROTHERM or equivalent as approved by Engineer-in-charge ), insulating heat resistant sleeves, sealing compounds varnish etc and reassembling the motor, including cooling fan as per existing make and type complete all as specified and directed. Note : (i) Winding wire will be measured and paid separately under relevant items. (ii) The contractor will furnish six months warranty against any kind of defect for the repair carried out after the date of installation. (iii) Cable for connection of suitable size min 3 mtr each length from motor included in above quoted rates. (iv) Rate shall be inclusive of loading/unloading and transporting to & from workshop.
Repair /Mantenance of CENTRIFUGAL booster motor and pump set 4 stage suitable for 415 volts 3 phase system having capacity 3 KW for chloronome plant, complete all as specified and directed..Make : KSB/CG/CRI/ KIRLOSKAR
M&L for MS flanged pipe of size 150 mm bore heavy duty 'C class with necessary MS bolts, nuts and washers, packing material, pressure gauge etc complete all as specified and as directed by Engr-in-charge.
Supply and replacement on load change over switch in sheet metal enclosure rated voltage 415 volts AC 50 Hz type FP 200 Amp, complete all as specified and directed. Make : L&T/C&S/BCH.
Supply and fixing in replacement of MCCB thermally adjustable 3 pole rating 160 Amp,25 KA, complete all as specified and directed. Make : Legrand/Schneider/Hager.
Supply and fixing in replacement of MCCB thermally adjustable 4 pole rating 63 Amp,25 KA, complete all as specified and directed. Make: Legrand/Schneider/Hager.
Supply and fixing in replacement of MCCB thermally adjustable 4 pole rating 160 Amp,25 KA, complete all as specified and directed. Make: Legrand/Schneider/Hager.
Supply and fixing in replacement of MCCB thermally adjustable 4 pole rating 200 Amp,25 KA, complete all as specified and directed. Make: Legrand/Schneider/Hager.
Supply and fixing in replacement of 3 pole power contactor AC-3 rating 50 Amp, with 1NO/1NC auxilary 230 V contact as required on site complete all as specified and directed. Make: Schneider/BCH/L&T
Supply and fixing in replacement of 3 pole power contactor AC-3 rating 70 Amp,with 1NO/1NC auxilary 230 V contact as required on site complete all as specified and directed. Make: Schneider/BCH/L&T
Supply and fixing in replacement of 3 pole power contactor AC-3 rating 80 Amp, with 1NO/1NC auxilary 230 V contact as required on sitecomplete all as specified and directed. Make: Schneider/BCH/L&T
Supply and fixing in replacement of Bimetallic type overload Relay range 20-33 Amp, complete all as specified and directed.Make: Schneider/BCH/L&T
Supply and fixing in replacement of Bimetallic type overload, Relay range 30-50 Amp, complete all as specified and directed. Make: Schneider/BCH/L&T
Supply and fixing in replacement of Bimetallic type overload Relay range 55-70 Amp, complete all as specified and directed. Make: Schneider/BCH/L&T
S&F in repair contactor mountable auxilary contact block consisting of 1 NO and 1 NC, 230 Volt operated complete all as specified and directed
S&F in repair single phase preventor relay 415V AC complete. Make: L&T/Minilec/BCH
S&F in repair electronic star delta timer with delay 0-30 sec 415V AC. Make: L&T/Minilec/Havells
Supply and fixing HRFR,PVC insulated 3 Core sheathed industrial HV flat cable copper conductor 1100 V size 16 Sqmm all as specified abd directed by Engr-in-Charge. Make: RR Kabel/Havells/Finolex
Supply and fixing HRFR,PVC insulated 3 Core sheathed industrial HV flat cable copper conductor 1100 V size 10 Sqmm all as specified abd directed by Engr-in-Charge. Make: RR Kabel/Havells/Finolex
Supply and fixing HRFR,PVC insulated 3 Core sheathed industrial HV flat cable copper conductor 1100 V size 06 Sqmm all as specified abd directed by Engr-in-Charge. Make: RR Kabel/Havells/Finolex
Supply and fixing three core 2.5 sq mm stranded copper conductor non sheathed twisted cable suitable for 1100 V operation complete all as specified and directed by Engineer in Charge. Make: RR Kabel/Havells/Finolex
Taking out GI Tubing 20 mm dia nominal bore including old fittings and removal to store all as specified and directed by Engr-in-charge.
Supplying, fixing, connecting & testing of GI tubing 20mm bore medium grade, ISI marked including all fittings, fixed to walls etc, complete all as specified and directed by Engineer-in-charge. Make: JINDAL/TATA/SURYA/PRAKASH. Note: (a) Cost of GI bends, sockets, unions and connected items will be deemed included in the unit rate quoted by the contractor.
Taking out old unserviceable PVC taps and supply and fixing PVC tap standard of PTMT in colour ( as directed by Engr-in- charge) high pressure screwed for iron pipe of size 15mm dia nominal bore. Make - Prayag/Shakti/Plytof
Supply and fixing in replacement of Gun metal globe or Gate valves with ironwheel head,screwed both ends for iron pipe of 20 mm dia bore complete all as specified and directed Make -BIR/Leader/Zoloto.
S&F in repair non return valve 20mm dia bore brass complete.Make -BIR/Leader/Zoloto.
Supply and fix CI Air release valve with two air outlets of size 50 mm dia bore and properly fixing in cast iron water supply mains, complete all as specified & directed by Engr-in-charge.
Supply and fix CI sluice valve with forged brass stem class PN- 1.6 ISI marked with stainless steel spindal and flanged both ends of size 150 mm dia bore with hand wheel. Make : Leader/ KIRLOSKAR/BIR ( ISI Marked )
S&F in repair DOL starter 3 phase 415V AC 7.5 HP capacity relay range 9 to 14 amps. Make:L&T/BCH/C&S
S&F in repair star delta starter 3 phase 415V AC 12.5 HP capacity relay range 16 to 20 Amps. Make:L&T/BCH/C&S
Supply only calcium Hypochlorite Granuals chlorine 65% to 70% in grannular form Hi strength in company sealed packing of fresh lot for drinking water treatment purpose. Make: As approved by E-in-C's Branch. Note: Item should be supplied in two installments.
Supply only high quality Trichloroisocyanuric acid Granular(TCCA-90%) chlorine powder for swimming pool disinifection purpose as required on site, complete all as specified and directed by Engr-in-Charge Note: Item should be supplied in two installments.
Supply only alum (fitkari) in loose form for swimming pool disinifection purpose.
Supply only copper sulphate (Nila Thatha) in loose form for swimming pool disinifection purpose.
Supply of Bleaching powder in bags/buckets Make: As approved by E-in-C's Branch. Note The material will be supplied in two installments as directed by Engr-in-Charge during the entire contact period.
S&F in repalacement digital voltmeter size 96x96mm 0 to 500V AC 3 phase class-1 Make: Meco/Risabh/AE
S&F in replacement digital Ammeter size 96x96mm 0 to 200A AC suitable for CT of secondary current 5A class-1 Make: Meco/Risabh/AE
S&F LED 18W (4') Decorative ultra slim linear LED lighting fixture with extruded polycarbonate, environmental friendly, energy fficient ready to use pack., ready to use pack, 230 volts, 50 Hz complete. Make: Havells/Philips/Wipro
Supply and fixing in replacement Ball bearing No 6304 , complete all as specified and directed.Make : SKF Or equivalent as approved By GE.
Supply and fixing in replacement Ball bearing No 7310, complete all as specified and directed.Make : SKF Or equivalent as approved By GE.
Material and labour for cleaning away all grass vegatation sapling shrubs bushes from under roots and tress not exceeding 30 cm grith and removing upto distance of 50 mtr out the periphery of area under cleaness complete all as specified and directed.Note : T&P required for this job to be brought by the contractor.
Supply and fixing glyphosate 41% SL Glykol Herbicide to remove vegatation from E/M Installations complete all as specified and directed by Engr-in-Charge
Material and labour for development of bore well with high capacity air compresser of suitable sizefor running duration not less than 4 hours till the water becomes sand and silt free including removal of liquid mud, sand, silt etc up to a distance of 50 metre and deposited where directed, complete all as specified & directed. Note: (a) Air compressor, fuel, manpower, any other equipment of suitable capacity for the development of tube well shall be arranged by the contractor under his own arrangements and nothing extra shall be payable to the contractor on this account. (b) The discharge shall be measured by providing orifice system of 'V' notch fixed to steel tanks of adequate capacity. (c) A proper record and log sheet for running of compressor shall be prepared and signed by the contractor & Engineer-in-Charge, countersigned by GE and shall form part of final bill.
diamond electrical
Harai Sharan Govt Contractor
P S BUILDERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .