Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹45.7 LAccepted-AOC | L1 | Accepted-AOC BEING LOWEST BIDDDER | |
| 2 | L2₹47.3 L+₹1.6 L (3.43%)Rejected-Finance HOUSE NO 251 E BLOCK ADARSH NAGAR BALLABHGARH FARIDABAD PIN 121004 HARYANA | FARIDABAD | FARIDABAD | HARYANA | 121004 | L2 | Rejected-Finance OTHER THAN LOWEST | |
| 3 | L3₹47.5 L+₹1.8 L (3.86%)Rejected-Finance 252 22 NEAR SOCITY BUS STAND INDRA COLONY PATHANKOT 145001 | PATHANKOT | PUNJAB | 145001 | L3 | Rejected-Finance OTHER THAN LOWEST | |
| 4 | L4₹47.8 L+₹2.0 L (4.46%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN LOWEST | |
| 5 | L5₹50.1 L+₹4.3 L (9.49%)Rejected-Finance | L5 | Rejected-Finance OTHER THAN LOWEST |
Tender Value
₹45.1 L
EMD Value
₹90,300
Closing Date
11 Sept 2023, 6:00 pmClosed
GE 865 EWS
GE 865 EWS, PIN-913 865 C/o 56 APO
PROVN OF HEATING SYSTEM AND CONNECTED ACCESSORIES AT RAINA AUDITORIUM HALL HQ 14 CORPS SPECIAL REPAIR TO 100 FCUs AND PROVN OF CERTAIN REVENUE AND MINOR WORK UNDER GE 865 EWS AT LEH
2023_MES_600020_2
865/EWS(NIT-60)/2023-24
Open Tender
Civil Works
Item Rate
180 days
GE 865 EWS
As per tender documents and as per policy in vogue
9 documents required · 9 mandatory
₹500
GE 865 EWS
₹90,300
Yes
12 Oct 2023
29 Aug 2023
18 Sept 2023
29 Aug 2023
11 Sept 2023
5 Sept 2023
Amount
Supply and install 2 TR hi wall split units indoor/ outdoor complete with cordless remote control unit and with in built Heating and Cooling arrangement and Digital Inverter twin rotary of capacity as shown including suitable length of coppe pipes for connection complete all as specified and directed by Engineer in Charge.
Supply and fixing voltage stabilizer for automatic operation, single phase naturally air cooled indoor type and designed for input variation between 170 to 250 volt with output voltage stabilzed at 230 volt with accuracy of plus minus 2.5% and of capacity 5.0 KVA complete all as specified and directed by Engineer-in-Charge.
M&L for point wiring for power point 3 Pin switch socket 15 Amp with PVC copper conductor cable (FRLSH) multistrand unsheathed 4 Sqmm on independent board including one run 4 Sqmm multistrand PVC copper conductor cable for earth continuity in and including PVC casing and caping fixed on wall complete all as specified and directed by Engineer-in-Charge. Make: Havells/Finolex/Anchor.
Supply and fixing single pole and neutral enclosure with one pin of earth plug and socket complete with one No of MCB capacity 20 Amps complete all as specified and directed.
Supply, Installation, testing and Commissioning of ductable type standalone oil fired kerosene/HSD based heating system (Top mounting) complete with stainless steel heat exchanger chamber consisting of furnace fabricated out of high temperature resistence stainless steel, automatic burner assembly control panel with sequence controller, photocell, for flame failure. HT transformer electrode fan assembly with motor temperature controller stainless steel reflector, built in fuel oil piping exhaust chimney all housed in powder coated cashing suitable for operation on 50 Hz single phase 230 volt AC supply capacity 75000 KCal/ hr complete with following parameters:- (a) Heat Output - 75000 KCal/Hr. (b) Hot Air Temp - 40° C (c) Temperature Rise - 90° C Max (d) Fuel Consumption - 5.2- 5.6 Lt/Hr (e) Thermal Efficiency - 80-90% (f) Electrical Supply - 220 Volts 50 Hz (g) Temperature Control - Automatic (h) Fuel - Kerosene/ Diesel (j) Burner - Riello / Ben-tone Make- Top Mind Industries Private Limited/ ECCO Flame/ Flameco/ Thermex
Design, supply, Fixing and testing ducting for hot air blower to room with complete insulation of the duct complete all as specified and directed by Engineer-in-Charge.
Supply and Fix in replacement of old unsv wall mounted FCU of capacity 6000 K Cal/hr all as specified and directed by Engr-in-Charge. Note: Old FCUs will be deposited to MES store for further necessary action.
Supply and Fix in replacement of old unsv wall mounted FCU of capacity 4500 K Cal/hr all as specified and directed by Engr-in-Charge. Note: Old FCUs will be deposited to MES store for further necessary action.
Supply and Fix in replacement FCU connection flexible pipe 20/16mm as per existing and as per required length complete all as specified and directed by Engineer-in-Charge.
Supply and Fix in replacement of inlet outlet Ball valve 20mm for FCU as per existing including supply and fixing MS /GI nipple of size 20mm including welding work including cutting the existing rusty unserviceable MS/GI nipple complete all as specified and directed by Engineer-in-Charge.
Supply and Fix in replacement of inlet outlet Ball valve 25mm for FCU as per existing including supply and fixing MS /GI nipple of size 20mm including welding work including cutting the existing rusty unserviceable MS/GI nipple complete all as specified and directed by Engineer-in-Charge.
national engineering
VIMAL TRADERS AND SUPPLIERS
M/S MALIK CHAND SIRI RAM
M/S LIBE & CO
M/S NANCY ENTERPRISES
EESSI
bharat construction
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .